3RH1921-1XA22 [SIEMENS]

Contactors / 3RH Control Relays; 接触器/ 3RH中间继电器
3RH1921-1XA22
型号: 3RH1921-1XA22
厂家: Siemens Semiconductor Group    Siemens Semiconductor Group
描述:

Contactors / 3RH Control Relays
接触器/ 3RH中间继电器

继电器
文件: 总4页 (文件大小:552K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Contactors and Contactor Assemblies  
SIRIUS  
3RT Contactors / 3RH Control Relays  
Accessories for contactors,  
control relays and auxiliary contactors  
Selection and ordering data  
3RH19 11-1HA..  
-1FA..  
3RH19 11-2HA ..  
-2FA..  
3RH19 21-1HA..  
Screw connection  
Order No.  
3RH19 21-2HA ..  
3RH19 11-1AA..  
3RH19 11-1LA..  
For  
contactors  
Rated operational Auxiliary contacts  
Cage Clamp connection  
Weight  
approx.  
current 2)  
NEMA A600 / Q600 Ident.  
no.  
Design  
List  
Price $  
Order No.  
List  
Price $  
Type  
NO NC NO NC  
kg  
Auxiliary switch blocks for snapping onto the front  
acc. to EN 50 012 1)  
Size S00  
For making contactors with 2, 4 or 5 auxiliary contacts  
3RT10 1. -1... 1,  
3RT10 1. -2... 1  
Ident. no. 10E  
11 E  
22 E  
23 E  
32 E  
1
1
2
1
2
3
2
3RH19 11-1HA01  
3RH19 11-1HA12  
3RH19 11-1HA13  
3RH19 11-1HA22  
10.00  
21.00  
28.00  
28.00  
3RH19 11-2HA01  
3RH19 11-2HA12  
3RH19 11-2HA13  
3RH19 11-2HA22  
11.00 0.045  
24.00  
32.00  
32.00  
Sizes S0 to S12 1)  
4-pole  
3RT10 2,  
3RT1. 3 to  
3RT1. 7,  
3RT11  
31  
22  
13  
3
2
1
1
2
3
3RH19 21-1HA31  
3RH19 21-1HA22  
3RH19 21-1HA13  
40.00  
40.00  
40.00  
3RH19 21-2HA31  
3RH19 21-2HA22  
3RH19 21-2HA13  
44.00 0.065  
44.00  
44.00  
with location digits 22  
5, 6, 7, 8  
2
2
3RH19 21-1XA22-0MA0  
44.00  
3RH19 21-2XA22-0MA0  
48.00  
Auxiliary switch blocks for snapping onto the front  
acc. to EN 50 005 1)  
Size S00  
2 or 4-pole auxiliary switch blocks for making contactors with 3 or 5 auxiliary contacts  
3RT1. 1,  
3RH11,  
3RH14  
20  
2
1
1
2
1
1
3RH19 11-1FA20  
3RH19 11-1FA11  
3RH19 11-1FA02  
3RH19 11-1FB11  
14.00  
14.00  
14.00  
14.00  
3RH19 11-2FA20  
3RH19 11-2FA11  
3RH19 11-2FA02  
3RH19 11-2FB11  
16.00 0.045  
16.00  
11  
02  
11 U  
16.00  
30.00  
40  
31  
22  
22 U  
4
3
2
1
2
1
2
1
2
1
3RH19 11-1FA40  
3RH19 11-1FA31  
3RH19 11-1FA22  
3RH19 11-1FC22  
3RH19 11-1FB22  
28.00  
28.00  
28.00  
42.00  
42.00  
3RH19 11-2FA40  
3RH19 11-2FA31  
3RH19 11-2FA22  
3RH19 11-2FC22  
32.00 0.045  
32.00  
32.00  
46.00  
11, 11 U 1  
Single or 2-pole auxiliary switch blocks, cable entry from one side  
Cable entry from above  
1
1
2
1
1
3RH19 11-1AA10  
3RH19 11-1AA01  
3RH19 11-1LA11  
3RH19 11-1LA20  
10.00  
10.00  
14.00  
14.00  
0.015  
0.045  
Cable entry from below  
1
1
2
1
1
3RH19 11-1BA10  
3RH19 11-1BA01  
3RH19 11-1MA11  
3RH19 11-1MA20  
10.00  
10.00  
14.00  
14.00  
0.015  
0.045  
1) Exception: 3RT16.  
2) UL ratings on page 19/18 in section 19.  
EN50005 and EN50012 designate the markings  
of the auxiliary terminal numbers.  
For position of the terminals see pages 2/154-156.  
For int. circuit diagrams see pages 2/150-151  
Siemens Energy & Automation, Inc.  
Industrial Controls Catalog  
Discount Code: SIRIUS Contactors, OLs, MSP’s  
2/41  
Contactors and Contactor Assemblies  
3RT1 Contactors  
SIRIUS  
Accessories for contactors  
Selection and ordering data  
3RH19 21-1F...  
3RH19 21-2F...  
3RH19 21-1C ...  
3RH19 21-2C...  
3RH19 21-1LA..  
3RH19 21-1MA..  
For  
contactors  
Rated operational Auxiliary contacts  
current 2)  
Screw connection  
Cage Clamp connection  
Weight Pack.  
approx.  
NEMA A600 / Q600 Ident.  
no.  
Design  
Order No.  
List  
Price $  
Order No.  
List  
Price $  
Type  
NO NC NO NC  
kg  
Auxiliary switch blocks for snapping onto the front  
acc. to EN 50 005  
Sizes S0 to S12 1)  
4-pole auxiliary switch blocks  
3RT10 2,  
3RT1. 3 to  
3RT1. 7,  
3RT11  
40  
4
3
2
1
2
4
2
2
3RH19 21-1FA40  
3RH19 21-1FA31  
3RH19 21-1FA22  
3RH19 21-1FA04  
3RH19 21-1FC22  
40.00  
40.00  
40.00  
40.00  
54.00  
3RH19 21-2FA40  
3RH19 21-2FA31  
3RH19 21-2FA22  
3RH19 21-2FA04  
3RH19 21-2FC22  
44.00 0.065  
1 unit  
1 unit  
31  
44.00  
44.00  
44.00  
58.00  
22  
04  
22 U  
Single-pole auxiliary switch blocks acc. to EN 50 005 and EN 50 012  
3RT1. 2 to  
3RT1. 7,  
3RT11  
1
1
1
1
3RH19 21-1CA10  
3RH19 21-1CA01  
3RH19 21-1CD10  
3RH19 21-1CD01  
10.00  
10.00  
20.00  
20.00  
3RH19 21-2CA10  
3RH19 21-2CA01  
11.00 0.015  
11.00  
2-pole auxiliary switch blocks with cable entry from one side  
Cable entry from above  
3RT10 2,  
3RT1. 3 to  
3RT1. 7,  
3RT11  
1
2
1
2
3RH19 21-1LA11  
3RH19 21-1LA20  
3RH19 21-1LA02  
20.00  
20.00  
20.00  
0.065  
0.065  
1 unit  
1 unit  
Cable entry from below  
1
2
1
2
3RH19 21-1MA11  
3RH19 21-1MA20  
3RH19 21-1MA02  
20.00  
20.00  
20.00  
1) Exception: 3RT16.  
2) UL ratings on page 19/18 in section 19.  
EN50005 and EN50012 designate the markings  
of the auxiliary terminal numbers.  
For position of the terminals see pages 2/154-156.  
For int. circuit diagrams see pages 2/149-151.  
2/42  
Discount Code: SIRIUS Contactors, OLs, MSP’s  
Siemens Energy & Automation, Inc.  
Industrial Controls Catalog  
Contactors and Contactor Assemblies  
SIRIUS  
3RT1 Contactors  
Accessories for contactors  
Selection and ordering data  
3RH19 21-1DA11  
-1JA11  
3RH19 21-2DA11  
-2JA11  
3RH19 21-1EA..  
-1KA..  
3RH19 21-2EA..  
-2KA..  
For  
contactors  
Auxiliary contacts  
Screw connection  
Cage Clamp connection  
Weight  
approx.  
Rated operational current  
NEMA A300 / Q300 1)  
Order No.  
List  
Order No.  
List  
Design  
Price $  
Price $  
Type  
NO NC  
kg  
Laterally mountable auxiliary switch blocks acc. to EN 50 012  
Sizes S0 to S12  
First laterally mountable auxiliary switch block (right or left), 2-pole  
3RH19 21-1DA11 20.00  
3RH19 21-2DA11 22.00  
3RT1. 2  
to  
3RT1. 7  
1
1
0.038  
Sizes S3 to S12  
Second laterally mountable auxiliary switch block (right or left), 2-pole  
3RH19 21-1JA11  
3RH19 21-2JA11  
22.00  
3RT1. 4  
to  
3RT1. 7  
1
1
20.00  
0.038  
Laterally mountable auxiliary switch blocks acc. to EN 50 005  
Sizes S0 to S12  
First laterally mountable auxiliary switch block (right or left), 2-pole  
3RT1. 2  
to  
2
1
1
2
3RH19 21-1EA20 20.00  
3RH19 21-1EA11 20.00  
3RH19 21-1EA02 20.00  
3RH19 21-2EA20 22.00  
0.038  
0.038  
3RT1. 7  
3RH19 21-2EA02 22.00  
Sizes S3 to S12  
Second laterally mountable auxiliary switch block (right or left), 2-pole  
3RT1. 4  
to  
3RT1. 7  
2
1
1
2
3RH19 21-1KA20 20.00  
3RH19 21-1KA11 20.00  
3RH19 21-1KA02 20.00  
3RH19 21-2KA20 22.00  
3RH19 21-2KA02 22.00  
1) UL ratings on page 19/18 in section 19.  
EN50005 and EN50012 designate the markings  
of the auxiliary terminal numbers.  
For position of the terminals see pages 2/154-157.  
For int. circuit diagrams see pages 2/150-151.  
Siemens Energy & Automation, Inc.  
Industrial Controls Catalog  
Discount Code: SIRIUS Contactors, OLs, MSP’s  
2/43  
Contactors and Contactor Assemblies  
3RT1 Contactors and 3RH1 Control Relays  
SIRIUS  
Accessories for contactors and control relays  
Selection and ordering data  
3RH19 11-1NF ..  
3RH19 11-2NF..  
3RH19 21-1FE22  
Screw connection  
3RH19 21-2FE22  
3RH19 21-2DE11  
-2JE11  
For  
Design  
Contacts  
Design  
Cage Clamp connection  
Weight  
approx.  
contactors /  
control relays  
Order No.  
List  
Order No.  
List  
Price $  
Price $  
Type  
NO NO NC NC  
kg  
Solid-state compatible auxiliary switch blocks,  
for snapping onto the front, acc. to EN 50 005  
Size S00  
3RT1. 1,  
3RH11,  
3RH14  
For use in dusty atmosphere and elec-  
tronic circuits with rated operational  
currents from 1 mA to 300 mA  
at 3 V to 60 V.  
1
2
1
2
3RH19 11-1NF11  
3RH19 11-1NF20  
3RH19 11-1NF02  
63.00  
63.00  
63.00  
3RH19 11-2NF11  
3RH19 11-2NF20  
3RH19 11-2NF02  
65.00 0.045  
65.00  
65.00  
Hard gold-plated contacts.No posi-  
tively driven operation  
Sizes S0 to S12  
3RT1. 2  
to  
3RT1. 7  
1 NO + 1 NC solid-state compatible  
1
1
1
1
3RH19 21-1FE22  
79.00  
3RH19 21-2FE22  
79.00 0.065  
auxiliary switches:  
For use in dusty atmosphere and elec-  
tronic circuits with rated operational  
currents 1 mA to 300 mA at 3 V to 60 V.  
Hard gold-plated contacts.  
1 NO + 1 NC standard auxiliary  
switches:  
For technical data, see page 2/91.  
Solid-state compatible auxiliary switch blocks,  
laterally mountable, acc. to EN 50 012  
Sizes S0 to S12  
First laterally mountable auxiliary switch block (right or left), 2-pole  
3RT1. 2  
to  
3RT1. 7  
1 NO + 1 NC solid-state compatible  
auxiliary switches:  
1
1
3RH19 21-2DE11  
58.00 0.038  
For use in dusty atmosphere and elec-  
tronic circuits with rated operational  
currents from 1 mA to 300 mA  
at 3 V to 60 V.  
Hard gold-plated contacts.  
Sizes S3 to S12  
Second laterally mountable auxiliary switch block (right or left), 2-pole  
3RT1. 4  
to  
3RT1. 7  
1 NO + 1 NC solid-state compatible  
auxiliary switches:  
1
1
3RH19 21-2JE11  
75.00 0.038  
For use in dusty atmosphere and elec-  
tronic circuits with rated operational  
currents from 1 mA to 300 mA  
at 3 V to 60 V.  
Hard gold-plated contacts.  
EN50005 and EN50012 designate the markings of the auxiliary terminal numbers.  
For position of the terminals see pages 2/154-156.  
For int. circuit diagrams see pages 2/150-151.  
2/44  
Discount Code: SIRIUS Contactors, OLs, MSP’s  
Siemens Energy & Automation, Inc.  
Industrial Controls Catalog  

相关型号:

3RH1921-2HA13

3RT Contactors / 3RH Control Relays
SIEMENS

3RH1921-2HA22

3RT Contactors / 3RH Control Relays
SIEMENS

3RH1921-2HA31

3RT Contactors / 3RH Control Relays
SIEMENS

3RH1921-2XA22

3RT Contactors / 3RH Control Relays
SIEMENS

3RH19211CA10

Contactors with Extended Tolerance 0.7 ... 1.25 x , for Railway Applications
SIEMENS

3RHP

Hybrid Solid State Contactors
CRYDOM

3RHP1240D12

Panel Mount
CRYDOM

3RHP1240D24

Hybrid Solid State Contactors
CRYDOM

3RHP1240D5

Panel Mount
CRYDOM

3RHP1240E

Hybrid Solid State Contactors
CRYDOM

3RHP1240F

Hybrid Solid State Contactors
CRYDOM

3RHP1240G

Hybrid Solid State Contactors
CRYDOM