3RHP [CRYDOM]

Hybrid Solid State Contactors; 混合型固态接触器
3RHP
型号: 3RHP
厂家: CRYDOM INC.,    CRYDOM INC.,
描述:

Hybrid Solid State Contactors
混合型固态接触器

文件: 总2页 (文件大小:447K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
3 Phase RHP - Hybrid Solid State Contactors  
3 Phase Contactor  
3 Phase Contactor  
DC Input  
40-50 Amp  
120/240 VAC  
AC Input  
40-50 Amp  
280/600 VAC  
Combined SSR and EMR advantages  
Lifetime >2 million operations @ full load  
No heat sink required  
DC logic compatible input  
Input status LED indicator  
Wire, lug or quick connect termination  
DP contactor footprint  
Combined SSR and EMR advantages  
Lifetime >2 million operations @ full load  
No heat sink required  
Input status LED indicator  
Wire, lug or quick connect termination  
DP contactor footprint  
CE compliant & UL/cUL recognized  
CE compliant & UL/cUL recognized  
1
CONTROL SPECIFICATIONS  
Control Voltage Suffix  
Coil Voltage Range  
Min. Turn-On Voltage  
Min. Turn-Off Voltage  
Coil Power Consumption, Inrush  
Coil Power Consumption, Sealed  
Coil Terminals  
1
CONTROL SPECIFICATIONS  
Control Voltage Suffix  
Control Voltage Range  
Max. Reverse Voltage  
Min. Turn-On Voltage  
E
F
G
D5  
D12  
D24  
20 - 26 VAC, 50/60 Hz 100 - 130 VAC, 50/60 Hz 208 - 240 VAC, 50/60 Hz  
4.5 - 5.5 VDC  
-5.5 VDC  
4.5 VDC  
10 - 15 VDC  
-15.5 VDC  
9.5 VDC  
22 - 27 VDC  
-27.5 VDC  
9.5 VDC  
20 VAC  
12 VAC  
100 VAC  
208 VAC  
24 VAC  
48 VAC  
56 VA @ 24 VAC  
6.6 VA @ 24 VAC  
10 in lb (1.13 Nm)  
56 VA @ 120 VAC  
6.6 VA @ 120 VAC  
10 in lb (1.13 Nm)  
56 VA @ 220 VAC  
6.6 VA @ 220 VAC  
10 in lb (1.13 Nm)  
Min. Turn-Off Voltage  
Input Current  
1 VDC  
12mA @ 5 VDC  
5.31 in lb (0.6 Nm)  
2 VDC  
12mA @ 12 VDC  
5.31 in lb (0.6 Nm)  
2 VDC  
12mA @ 24 VDC  
5.31 in lb (0.6 Nm)  
Input Connector  
1
1
OUTPUT SPECIFICATIONS  
OUTPUT SPECIFICATIONS  
28  
60  
Voltage suffix  
Operating Voltage (50/60Hz)  
Voltage suffix  
Operating Voltage (50/60Hz)  
12  
24  
24 - 280 VAC  
48 - 600 VAC  
100 - 120 VAC  
208 - 240 VAC  
0.06 mA @ 240 VAC  
3
3
Maximum Off-State Leakage Current per channel  
0.05 mA @ 240 VAC  
0.06 mA @ 480 VAC  
Maximum Off-State Leakage Current per channel  
0.05 mA @ 120 VAC  
40  
50  
Load Current suffix  
Maximum Load Current per Phase @ 40°C  
Power terminals / wire range  
Load Current suffix  
Maximum Load Current per Phase @ 40°C  
Power terminals / wire range  
40  
50  
2
40 A Resistive  
50 A Resistive  
Dual quick connect and Box  
2
40 A Resistive  
50 A Resistive  
Dual quick connect and Binder  
Dual quick connect and Binder Dual quick connect and Box  
head screws / AWG#14 - AWG#8 lugs / AWG#14 - AWG#6  
head screws / AWG#14 - AWG#8 lugs / AWG#14 - AWG#6  
Screw torque requirements  
18 in lbs (2.1 Nm)  
25 in lbs (2.9 Nm)  
Screw torque requirements  
18 in lbs (2.1 Nm)  
25 in lbs (2.9 Nm)  
1
1
GENERAL SPECIFICATIONS  
Input to Output Dielectric Isolation.  
GENERAL SPECIFICATIONS  
Input to Output Dielectric Isolation  
4000 VAC  
2500 VAC  
4000 VAC  
Input/Output to Ground Dielectric Isolation.  
Input/Output to Ground Dielectric Isolation  
2500 VAC  
Three Normally Open  
-20°C to 75°C  
3
3
Contacts (Double Break )  
Three Normally Open  
Contacts (Double Break)  
4
4
Ambient Operating Temperature Range  
-20°C to 75°C  
-40°C to 100°C  
16.6 mS @ 60 Hz / 20 mS @ 50 Hz  
32 mS @ 60 Hz / 40 mS @ 50 Hz  
30 operations per min  
Ambient Operating Temperature Range  
Ambient Storage Temperature Range  
Max. Turn-On Time  
Ambient Storage Temperature Range  
Max. Turn-On Time  
Max. Turn-Off Time  
-40°C to 100°C  
16.6 mS @ 60 Hz / 20 mS @ 50 Hz  
32 mS @ 60 Hz / 40 mS @ 50 Hz  
30 operations per min  
Max. Turn-Off Time  
Maximum Number of Operations per Minute  
Maximum Number of Operations per Minute  
> 2 Million operations  
Lifetime @ Rated Load Current, 40°C ambient  
Lifetime @ Rated Load Current, 40°C ambient  
temp, 30 operations/min, Rated Vcontrol  
> 2 Million operations  
temp, 30 operations/min, Rated Vcontrol  
540 grs (1.19 lb)  
Weight (typical)  
540 grs (1.19 lb)  
Weight (typical)  
1
Specificationts @ 25°C unless otherwise noted.  
1
2
3
4
Specificationts @ 25°C unless otherwise noted.  
2
See Derating Curves for additional operational conditions.  
See Derating Curves for additional operational conditions.  
3
The RHP includes a Solid-State Relay. Therefore, the output is never completely open.  
The RHP includes an overtemperature protection for the Solid-State Module.  
The RHP includes a Solid-State Relay. Therefore, the output is never completely open.  
The RHP includes an overtemperature protection for the Solid-State Module.  
4
Part Number Nomenclature  
Derating Curves  
Load Current  
40: 40 Amps  
50: 50 Amps  
3RHPXX50XX  
3RHPXX40XX  
55  
50  
45  
40  
35  
30  
25  
20  
SERIES  
45  
40  
35  
30  
25  
20  
3 RHP 12 40 D5  
Three  
Phase  
Device  
Operating  
Voltage VAC  
50/60 Hz  
Nominal Coil  
Power lead size  
AWG # 6  
/Control Voltage  
Power lead size  
AWG # 6  
AWG # 8  
D5: 5 VDC  
D12: 12 VDC  
D24: 24 VDC  
12: 120 V 1-phase  
AWG # 8  
24: 240 V 3-phase  
or 1-phase  
Safe Operating Area  
Safe Operating Area  
E: 24 VAC  
F: 120 VAC  
G: 220 VAC  
28: 280 V 3-phase  
60: 600 V 3-phase  
25  
35  
45  
55  
65  
75  
25  
35  
45  
55  
65  
75  
Ambient Temperature, °C  
Ambient Temperature, °C  
3 Phase RHP - Hybrid Solid State Contactors  
5
Typical Electrical Connection for 3 Phase Applications  
(For output voltage options 24, 28, 60)  
AC Input/Control Voltage  
(E, F, G input versions)  
AC Input/Control Voltage  
3 Phase AC  
I L3  
I L2  
Line  
5L3  
3L2  
(E, F, G input versions)  
Operating Voltage  
I L3  
I L1  
120/240 VAC  
Single Phase  
R2  
5L3  
3L2  
1L1  
6T3  
R1  
Operating Voltage  
~
1L1  
~
~
~
3Ø  
4T2  
2T1  
Neutral  
I L1  
Load  
VLL  
DC Input/Control Voltage  
(D5, D12, D24 input versions)  
I L1  
IL1 = (IL2 + IL3) ≤ Rated current  
DC Input/Control Voltage  
(D5, D12, D24 input versions)  
AC Input/Control Voltage  
(E, F, G input versions)  
DO NOT apply any AC voltage to contactor coil connections, for DC versions only.  
Line  
I L3  
5L3  
3L2  
6
Optional Electrical Connections for Single Phase Applications  
I L2  
NC  
(For output voltage options 12, 24, 28, 60)  
120/240 VAC  
Single Phase  
Operating Voltage  
R2  
AC Input/Control Voltage  
(E, F, G input versions)  
1L1  
R1  
~
7
5L3=NC  
3L2  
6T3=NC  
R1  
Line  
Neutral  
DC Input/Control Voltage  
(D5, D12, D24 input versions)  
I L1  
120/240 VAC  
Single Phase  
Operating Voltage  
IL2 ≤ Rated current  
IL3 ≤ Rated current  
1L1  
~
IL2 + IL3 > Rated current  
Neutral  
5
Match VLL to voltage suffixes 28 & 60 for options E, F & G and 12 & 24 for options DX.  
The single phase supply voltage must be wired to terminal 1L1 and 3L2 for proper single phase operation.  
In applications switching two single phase loads (R1 and R2) where the combined load current exceeds  
the contactor’s rating (40 or 50 Amps) the return/neutral lead must not be wired through the contactor  
(see above drawing).  
DC Input/Control Voltage  
(D5, D12, D24 input versions)  
6
7
IL1 ≤ Rated current  

相关型号:

3RHP1240D12

Panel Mount
CRYDOM

3RHP1240D24

Hybrid Solid State Contactors
CRYDOM

3RHP1240D5

Panel Mount
CRYDOM

3RHP1240E

Hybrid Solid State Contactors
CRYDOM

3RHP1240F

Hybrid Solid State Contactors
CRYDOM

3RHP1240G

Hybrid Solid State Contactors
CRYDOM

3RHP1250D12

Hybrid Solid State Contactors
CRYDOM

3RHP1250D24

Panel Mount
CRYDOM

3RHP1250D5

Hybrid Solid State Contactors
CRYDOM

3RHP1250E

Hybrid Solid State Contactors
CRYDOM

3RHP1250F

Hybrid Solid State Contactors
CRYDOM

3RHP1250G

Hybrid Solid State Contactors
CRYDOM