1026580 [SICK]

CONTRAST SENSORS;
1026580
型号: 1026580
厂家: SICK AG    SICK AG
描述:

CONTRAST SENSORS

文件: 总8页 (文件大小:1758K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
KT5W-2N1216D  
KT5  
CONTRAST SENSORS  
KT5W-2N1216D | KT5  
CONTRAST SENSORS  
Ordering information  
A
B
C
D
E
F
Type  
KT5W-2N1216D  
Part no.  
1026580  
Other models and accessories www.sick.com/KT5  
Detailed technical data  
Features  
30.4 mm x 53 mm x 80 mm  
Dimensions (W x H x D)  
Sensing distance  
20 mm 1)  
± 3 mm  
H
I
Sensing distance tolerance  
Housing design (light emission)  
Light source  
Rectangular  
LED, RGB 2)  
470 nm, 525 nm, 640 nm  
Wave length  
J
Long and short side of housing, exchangeable  
Light emission  
Light spot size  
Light spot direction  
1.5 mm x 5.5 mm  
K
L
Vertical 3)  
Teach-in button  
Adjustment  
Static 2-point teach-in with manual fine adjustment  
Teach-in mode  
1)  
From front edge of lens.  
2)  
M
N
O
P
Q
R
S
T
Average service life: 100,000 h at T = +25 °C.  
U
3)  
In relation to long side of housing.  
Mechanics/electronics  
10 V DC ... 30 V DC 1)  
Supply voltage  
Ripple  
2)  
≤ 5 Vpp  
< 130 mA 3)  
10 kHz 4)  
Power consumption  
Switching frequency  
1)  
Limit values when operated in short-circuit protected network: max. 8 A.  
2)  
May not exceed or fall below U tolerances.  
v
3)  
4)  
5)  
6)  
7)  
Without load.  
With light/dark ratio 1:1.  
Signal transit time with resistive load.  
Short-circuit protected.  
Reference voltage DC 50 V.  
2
REGISTRATION SENSORS | SICK  
Online data sheet | 2018-07-08 09:57:24  
Subject to change without notice  
KT5W-2N1216D | KT5  
CONTRAST SENSORS  
50 µs 5)  
Response time  
NPN  
Switching output  
NPN: HIGH = approx. VS / LOW ≤ 2 V  
Switching output (voltage)  
Output current Imax.  
100 mA 6)  
NPN  
Input, teach-in (ET)  
Teach: U < 2 V  
Run: U = 10 V ... < UV  
25 ms, non-volatile memory  
Male connector M12, 5-pin  
Retention time (ET)  
Connection type  
Protection class  
II 7)  
UV connections, reverse polarity protected  
Output Q short-circuit protected  
Circuit protection  
Interference pulse suppression  
IP67  
Enclosure rating  
Weight  
400 g  
Zinc diecast  
Housing material  
1)  
Limit values when operated in short-circuit protected network: max. 8 A.  
2)  
May not exceed or fall below U tolerances.  
v
3)  
4)  
5)  
6)  
7)  
Without load.  
With light/dark ratio 1:1.  
Signal transit time with resistive load.  
Short-circuit protected.  
Reference voltage DC 50 V.  
Ambient data  
–10 °C ... +55 °C  
Ambient operating temperature  
Ambient storage temperature  
Shock load  
–25 °C ... +75 °C  
According to IEC 60068  
Classifications  
27270906  
27270906  
27270906  
27270906  
27270906  
27270906  
27270906  
27270906  
EC001820  
EC001820  
39121528  
ECl@ss 5.0  
ECl@ss 5.1.4  
ECl@ss 6.0  
ECl@ss 6.2  
ECl@ss 7.0  
ECl@ss 8.0  
ECl@ss 8.1  
ECl@ss 9.0  
ETIM 5.0  
ETIM 6.0  
UNSPSC 16.0901  
2018-07-08 09:57:24 | Online data sheet  
Subject to change without notice  
REGISTRATION SENSORS | SICK  
3
KT5W-2N1216D | KT5  
CONTRAST SENSORS  
Dimensional drawing (Dimensions in mm (inch))  
KT5-2 Teach-in, KT5-2 Display  
A
B
C
D
E
F
56 (2.20)  
28  
(1.10)  
Sensing distance  
20 mm (0.79 inch)  
Sensing distance  
10 mm (0.39 inch)  
Sensing distance  
40 mm (1.57 inch)  
9 (0.35)  
M5  
1
2
3.5  
(0.14)  
4.5  
(0.18)  
17.4  
(0.69)  
5
2
M
5
28(1.10)  
52 (2.05)  
80 (3.15)  
13  
(0.51)  
4
17  
(0.67)  
3
Lens (light transmission), can be exchanged for pos. 4  
M5 threaded mounting hole, 5.5 mm deep  
See dimensional drawings of lenses  
H
I
Blind screw can be replaced by pos. 1  
Connector M12 (rotatable up to 90°)  
Adjustments  
J
KT5-2 Display  
K
L
Teach  
+
RUN  
Q
2
3
1
4
+
M
N
O
P
Q
R
S
T
Function signal indicator (yellow)  
Pre-selection switch  
Teach-in button  
Bar graph (green)  
4
REGISTRATION SENSORS | SICK  
Online data sheet | 2018-07-08 09:57:24  
Subject to change without notice  
KT5W-2N1216D | KT5  
CONTRAST SENSORS  
Connection diagram  
cd-323  
1
4
3
2
5
BN  
BK  
BU  
WH  
GY  
+(L+)  
Q
-(M)  
Not connected  
Teach  
Concept of operation  
KT5-2 Display, Teach-in static  
1. Position mark  
2. Position background  
Teach  
+
Teach  
+
RUN  
RUN  
Q
Q
Q
Dark mark, small deflection  
+
+
Light background, large deflection  
Turn rotary switch to “Teach”  
position. Press and hold  
teach-in button > 1 s.  
Red emitted light and yellow  
LED flash.  
Press and hold teach-in button  
> 1 s.  
Fine adjustment possible using  
the “+”/“–” buttons.  
Yellow LED goes out.  
Optimum emitted light is selected.  
Note  
The bar display visualizes the detection reliability during teach-in. The more LEDs that illuminate, the better the teach-in:  
1 LED illuminates = operation not reliable – contrast difference too low  
≤ 4 LEDs illuminate = operation OK – sufficient contrast difference  
> 4 LEDs illuminate = reliable operation – high contrast difference  
Example  
Dark switching  
Light switching  
Internal signal  
received  
Switching  
threshold  
Switching  
threshold  
Internal signal  
received  
Output Q  
Output Q  
Switching characteristics  
The optimum emitted light is selected automatically.  
Light/dark setting is defined using teach-in sequence.  
The switching threshold is set in the center between the background and the mark.  
Teach-in can also be performed using an external control signal.  
2018-07-08 09:57:24 | Online data sheet  
Subject to change without notice  
REGISTRATION SENSORS | SICK  
5
KT5W-2N1216D | KT5  
CONTRAST SENSORS  
Characteristic curve  
A
B
C
D
E
F
KT5-2 Teach-in, KT5G, KT5W, KT5-2 Display  
100  
90  
1
80  
70  
60  
50  
2
40  
30  
20  
3
10  
0
10  
(0.39)  
20  
(0.79)  
30  
(1.18)  
40  
(1.57)  
50  
(1.97)  
Sensing distance in mm (inch)  
Sensing distance 10 mm  
Sensing distance 20 mm  
Sensing distance 40 mm  
H
I
J
Recommended accessories  
Other models and accessories www.sick.com/KT5  
K
L
Brief description  
Type  
Part no.  
Universal bar clamp systems  
Plate G for universal clamp bracket, steel, zinc coated, Universal clamp (2022726),  
mounting hardware  
BEF-KHS-G01  
2022464  
M
N
O
P
Q
R
S
T
Plate K for universal clamp bracket, steel, zinc coated, Universal clamp (2022726),  
mounting hardware  
BEF-KHS-K01  
BEF-KHS-KH1  
2022718  
2022726  
Universal clamp bracket for rod mounting, steel, zinc coated, without mounting hard-  
ware  
Mounting bar, straight, 200 mm, steel, steel, zinc coated, without mounting hardware  
Mounting bar, straight, 300 mm, steel, steel, zinc coated, without mounting hardware  
BEF-MS12G-A  
BEF-MS12G-B  
4056054  
4056055  
Mounting bar, L-shaped, 150 mm x 150 mm, steel, steel, zinc coated, without mounting  
hardware  
BEF-MS12L-A  
BEF-MS12L-B  
4056052  
4056053  
Mounting bar, L-shaped, 250 x 250 mm, steel, steel, zinc coated, without mounting  
hardware  
6
REGISTRATION SENSORS | SICK  
Online data sheet | 2018-07-08 09:57:24  
Subject to change without notice  
KT5W-2N1216D | KT5  
CONTRAST SENSORS  
Brief description  
Type  
Part no.  
Plug connectors and cables  
Head A: female connector, M12, 5-pin, straight, A-coded  
YF2A15-020VB5XLEAX  
2096239  
Head B: Flying leads  
Cable: Sensor/actuator cable, PVC, unshielded, 2 m  
Head A: female connector, M12, 5-pin, straight, A-coded  
Head B: Flying leads  
Cable: Sensor/actuator cable, PVC, unshielded, 5 m  
YF2A15-050VB5XLEAX  
YF2A15-100VB5XLEAX  
YG2A15-020VB5XLEAX  
YG2A15-050VB5XLEAX  
YG2A15-100VB5XLEAX  
DOS-1205-G  
2096240  
2096241  
2096215  
2096216  
2096217  
6009719  
Head A: female connector, M12, 5-pin, straight, A-coded  
Head B: Flying leads  
Cable: Sensor/actuator cable, PVC, unshielded, 10 m  
Head A: female connector, M12, 5-pin, angled, A-coded  
Head B: Flying leads  
Cable: Sensor/actuator cable, PVC, unshielded, 2 m  
Head A: female connector, M12, 5-pin, angled, A-coded  
Head B: Flying leads  
Cable: Sensor/actuator cable, PVC, unshielded, 5 m  
Head A: female connector, M12, 5-pin, angled, A-coded  
Head B: Flying leads  
Cable: Sensor/actuator cable, PVC, unshielded, 10 m  
Head A: female connector, M12, 5-pin, straight  
Cable: unshielded  
Head A: female connector, M12, 5-pin, angled  
Head B: -  
DOS-1205-W  
6009720  
Cable: unshielded  
Lenses and accessories  
Lens, 40 mm sensing distance, M20 x 0.75  
Lens, 10 mm sensing distance, M20 x 0.75  
Lens, 20 mm sensing distance, M20 x 0.75  
OBJ-210  
OBJ-211  
OBJ-212  
2010945  
1004936  
1011506  
2018-07-08 09:57:24 | Online data sheet  
Subject to change without notice  
REGISTRATION SENSORS | SICK  
7

相关型号:

1026581

CONTRAST SENSORS
SICK

10266-3

Hybrid Couplers
ANAREN

1026758

Barrier Strip Terminal Block,
PHOENIX

10268-0

D Type Connector, Female, IDC Terminal, Receptacle
3M

10268-0210EC

050, Mini D Ribbon (MDR) Connectors
3M

10268-5242VC

D Type Connector, 68 Contact(s), Female, 0.05 inch Pitch, Solder Terminal, Latch, Plug
3M

10268-52E2VC

CONNECTOR,D-SHELL,PCB MNT,PLUG,68 CONTACTS,SKT,0.05 PITCH,PC TAIL TERMINAL,LATCH
3M

10268-55G3JC

3M Mini D Ribbon (MDR) Connectors
3M

10268-55G3JL

3M Mini D Ribbon (MDR) Connectors
3M

10268-55G3PC

3M Mini D Ribbon (MDR) Connectors
3M

10268-55G3PL

3M Mini D Ribbon (MDR) Connectors
3M

10268-55G3VC

3M Mini D Ribbon (MDR) Connectors
3M