1026581 [SICK]
CONTRAST SENSORS;KT5W-2N1216D
KT5
CONTRAST SENSORS
KT5W-2N1216D | KT5
CONTRAST SENSORS
Ordering information
A
B
C
D
E
F
Type
KT5W-2N1216D
Part no.
1026580
Other models and accessories www.sick.com/KT5
Detailed technical data
Features
30.4 mm x 53 mm x 80 mm
Dimensions (W x H x D)
Sensing distance
20 mm 1)
± 3 mm
H
I
Sensing distance tolerance
Housing design (light emission)
Light source
Rectangular
LED, RGB 2)
470 nm, 525 nm, 640 nm
Wave length
J
Long and short side of housing, exchangeable
Light emission
Light spot size
Light spot direction
1.5 mm x 5.5 mm
K
L
Vertical 3)
Teach-in button
Adjustment
Static 2-point teach-in with manual fine adjustment
Teach-in mode
1)
From front edge of lens.
2)
M
N
O
P
Q
R
S
T
Average service life: 100,000 h at T = +25 °C.
U
3)
In relation to long side of housing.
Mechanics/electronics
10 V DC ... 30 V DC 1)
Supply voltage
Ripple
2)
≤ 5 Vpp
< 130 mA 3)
10 kHz 4)
Power consumption
Switching frequency
1)
Limit values when operated in short-circuit protected network: max. 8 A.
2)
May not exceed or fall below U tolerances.
v
3)
4)
5)
6)
7)
Without load.
With light/dark ratio 1:1.
Signal transit time with resistive load.
Short-circuit protected.
Reference voltage DC 50 V.
2
REGISTRATION SENSORS | SICK
Online data sheet | 2018-07-08 09:57:24
Subject to change without notice
KT5W-2N1216D | KT5
CONTRAST SENSORS
50 µs 5)
Response time
NPN
Switching output
NPN: HIGH = approx. VS / LOW ≤ 2 V
Switching output (voltage)
Output current Imax.
100 mA 6)
NPN
Input, teach-in (ET)
Teach: U < 2 V
Run: U = 10 V ... < UV
25 ms, non-volatile memory
Male connector M12, 5-pin
Retention time (ET)
Connection type
Protection class
II 7)
UV connections, reverse polarity protected
Output Q short-circuit protected
Circuit protection
Interference pulse suppression
IP67
Enclosure rating
Weight
400 g
Zinc diecast
Housing material
1)
Limit values when operated in short-circuit protected network: max. 8 A.
2)
May not exceed or fall below U tolerances.
v
3)
4)
5)
6)
7)
Without load.
With light/dark ratio 1:1.
Signal transit time with resistive load.
Short-circuit protected.
Reference voltage DC 50 V.
Ambient data
–10 °C ... +55 °C
Ambient operating temperature
Ambient storage temperature
Shock load
–25 °C ... +75 °C
According to IEC 60068
Classifications
27270906
27270906
27270906
27270906
27270906
27270906
27270906
27270906
EC001820
EC001820
39121528
ECl@ss 5.0
ECl@ss 5.1.4
ECl@ss 6.0
ECl@ss 6.2
ECl@ss 7.0
ECl@ss 8.0
ECl@ss 8.1
ECl@ss 9.0
ETIM 5.0
ETIM 6.0
UNSPSC 16.0901
2018-07-08 09:57:24 | Online data sheet
Subject to change without notice
REGISTRATION SENSORS | SICK
3
KT5W-2N1216D | KT5
CONTRAST SENSORS
Dimensional drawing (Dimensions in mm (inch))
KT5-2 Teach-in, KT5-2 Display
A
B
C
D
E
F
56 (2.20)
28
(1.10)
Sensing distance
20 mm (0.79 inch)
Sensing distance
10 mm (0.39 inch)
Sensing distance
40 mm (1.57 inch)
9 (0.35)
M5
1
2
3.5
(0.14)
4.5
(0.18)
17.4
(0.69)
5
2
M
5
28(1.10)
52 (2.05)
80 (3.15)
13
(0.51)
4
17
(0.67)
3
① Lens (light transmission), can be exchanged for pos. 4
② M5 threaded mounting hole, 5.5 mm deep
③ See dimensional drawings of lenses
H
I
④ Blind screw can be replaced by pos. 1
⑤ Connector M12 (rotatable up to 90°)
Adjustments
J
KT5-2 Display
K
L
Teach
+
RUN
Q
–
2
3
1
4
–
+
M
N
O
P
Q
R
S
T
① Function signal indicator (yellow)
② Pre-selection switch
③ Teach-in button
④ Bar graph (green)
4
REGISTRATION SENSORS | SICK
Online data sheet | 2018-07-08 09:57:24
Subject to change without notice
KT5W-2N1216D | KT5
CONTRAST SENSORS
Connection diagram
cd-323
1
4
3
2
5
BN
BK
BU
WH
GY
+(L+)
Q
-(M)
Not connected
Teach
Concept of operation
KT5-2 Display, Teach-in static
1. Position mark
2. Position background
Teach
+
Teach
+
RUN
RUN
Q
Q
Q
Dark mark, small deflection
–
–
+
+
Light background, large deflection
–
Turn rotary switch to “Teach”
position. Press and hold
teach-in button > 1 s.
Red emitted light and yellow
LED flash.
Press and hold teach-in button
> 1 s.
Fine adjustment possible using
the “+”/“–” buttons.
Yellow LED goes out.
Optimum emitted light is selected.
Note
The bar display visualizes the detection reliability during teach-in. The more LEDs that illuminate, the better the teach-in:
1 LED illuminates = operation not reliable – contrast difference too low
≤ 4 LEDs illuminate = operation OK – sufficient contrast difference
> 4 LEDs illuminate = reliable operation – high contrast difference
Example
Dark switching
Light switching
Internal signal
received
Switching
threshold
Switching
threshold
Internal signal
received
Output Q
Output Q
Switching characteristics
The optimum emitted light is selected automatically.
Light/dark setting is defined using teach-in sequence.
The switching threshold is set in the center between the background and the mark.
Teach-in can also be performed using an external control signal.
2018-07-08 09:57:24 | Online data sheet
Subject to change without notice
REGISTRATION SENSORS | SICK
5
KT5W-2N1216D | KT5
CONTRAST SENSORS
Characteristic curve
A
B
C
D
E
F
KT5-2 Teach-in, KT5G, KT5W, KT5-2 Display
100
90
1
80
70
60
50
2
40
30
20
3
10
0
10
(0.39)
20
(0.79)
30
(1.18)
40
(1.57)
50
(1.97)
Sensing distance in mm (inch)
① Sensing distance 10 mm
② Sensing distance 20 mm
③ Sensing distance 40 mm
H
I
J
Recommended accessories
Other models and accessories www.sick.com/KT5
K
L
Brief description
Type
Part no.
Universal bar clamp systems
Plate G for universal clamp bracket, steel, zinc coated, Universal clamp (2022726),
mounting hardware
BEF-KHS-G01
2022464
M
N
O
P
Q
R
S
T
Plate K for universal clamp bracket, steel, zinc coated, Universal clamp (2022726),
mounting hardware
BEF-KHS-K01
BEF-KHS-KH1
2022718
2022726
Universal clamp bracket for rod mounting, steel, zinc coated, without mounting hard-
ware
Mounting bar, straight, 200 mm, steel, steel, zinc coated, without mounting hardware
Mounting bar, straight, 300 mm, steel, steel, zinc coated, without mounting hardware
BEF-MS12G-A
BEF-MS12G-B
4056054
4056055
Mounting bar, L-shaped, 150 mm x 150 mm, steel, steel, zinc coated, without mounting
hardware
BEF-MS12L-A
BEF-MS12L-B
4056052
4056053
Mounting bar, L-shaped, 250 x 250 mm, steel, steel, zinc coated, without mounting
hardware
6
REGISTRATION SENSORS | SICK
Online data sheet | 2018-07-08 09:57:24
Subject to change without notice
KT5W-2N1216D | KT5
CONTRAST SENSORS
Brief description
Type
Part no.
Plug connectors and cables
Head A: female connector, M12, 5-pin, straight, A-coded
YF2A15-020VB5XLEAX
2096239
Head B: Flying leads
Cable: Sensor/actuator cable, PVC, unshielded, 2 m
Head A: female connector, M12, 5-pin, straight, A-coded
Head B: Flying leads
Cable: Sensor/actuator cable, PVC, unshielded, 5 m
YF2A15-050VB5XLEAX
YF2A15-100VB5XLEAX
YG2A15-020VB5XLEAX
YG2A15-050VB5XLEAX
YG2A15-100VB5XLEAX
DOS-1205-G
2096240
2096241
2096215
2096216
2096217
6009719
Head A: female connector, M12, 5-pin, straight, A-coded
Head B: Flying leads
Cable: Sensor/actuator cable, PVC, unshielded, 10 m
Head A: female connector, M12, 5-pin, angled, A-coded
Head B: Flying leads
Cable: Sensor/actuator cable, PVC, unshielded, 2 m
Head A: female connector, M12, 5-pin, angled, A-coded
Head B: Flying leads
Cable: Sensor/actuator cable, PVC, unshielded, 5 m
Head A: female connector, M12, 5-pin, angled, A-coded
Head B: Flying leads
Cable: Sensor/actuator cable, PVC, unshielded, 10 m
Head A: female connector, M12, 5-pin, straight
Cable: unshielded
Head A: female connector, M12, 5-pin, angled
Head B: -
DOS-1205-W
6009720
Cable: unshielded
Lenses and accessories
Lens, 40 mm sensing distance, M20 x 0.75
Lens, 10 mm sensing distance, M20 x 0.75
Lens, 20 mm sensing distance, M20 x 0.75
OBJ-210
OBJ-211
OBJ-212
2010945
1004936
1011506
2018-07-08 09:57:24 | Online data sheet
Subject to change without notice
REGISTRATION SENSORS | SICK
7
相关型号:
![](http://pdffile.icpdf.com/pdf2/p00295/img/page/10268-52E2VC_1787054_files/10268-52E2VC_1787054_1.jpg)
![](http://pdffile.icpdf.com/pdf2/p00295/img/page/10268-52E2VC_1787054_files/10268-52E2VC_1787054_2.jpg)
10268-5242VC
D Type Connector, 68 Contact(s), Female, 0.05 inch Pitch, Solder Terminal, Latch, Plug
3M
©2020 ICPDF网 联系我们和版权申明