IS1U60 [SHARP]
Sensors with 1-Package Design of Remote Control Detecting Functions owing to OPIC; 感应器与遥控器的1 ,包装设计,由于检测到OPIC功能型号: | IS1U60 |
厂家: | SHARP ELECTRIONIC COMPONENTS |
描述: | Sensors with 1-Package Design of Remote Control Detecting Functions owing to OPIC |
文件: | 总5页 (文件大小:50K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
IS1U60/IS1U60L
Sensors with 1-Package Design
of Remote Control Detecting
Functions owing to OPIC
IS1U60/IS1U60L
(Unit : mm)
■ Features
■ Outline Dimensions
1. 1-package design owing to adoption of OPIC
2. Compact
IS1U60
3.5 3.5
3.4 3.4
2.9 3.6
(Volume : About 1/8 compared with GP1U58X)
3. B.P.F. (Band Pass Frequency) : (TYP. 38kHz)
4. Aspherical lens
■ Applications
1. Audio equipment
2. Cameras
+
-
0.2
0.1
0.4
1.0
0.5
2.1
1.5
2.54
2.54
1
2
3
VOUT
GND
VCC
1
2
3
*
Tolerance : ± 0.2
(Ta=25˚C)
■ Absolute Maximum Ratings
IS1U60L
Parameter
Supply voltage
*1Operating temperature
Symbol
VCC
Rating
0 to 6.0
- 10 to + 60
- 20 to + 70
260
Unit
V
3.5 3.5
3.4 3.4
2.9 3.6
T opr
˚C
Storage temperature
*2Soldering temperature
T stg
˚C
θ = 0 to 15˚
Tsol
˚C
*1 No dew condensation is allowed.
*2 For 5 seconds
θ
θ
1
2
3
2.1
1.5
±
1.0
4.2mm
3.1mm
15.2
1
2
3
VOUT
GND
VCC
Soldering area
Soldering area
*
Tolerance : ± 0.2
* "OPIC" (Optical IC) is a trademark of the SHARP Corporation.
An OPIC consists of a light-detecting element and signal-processing circuit
integrated onto a single chip.
■ Recommended Operating Conditions
Recommended
Parameter
Symbol
VCC
Unit
V
operating conditions
4.7 to 5.3
Operating supply voltage
“ In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device.”
IS1U60/IS1U60L
(Ta=25˚C, VCC =+5V)
■Electrical Characteristics
Parameter
Dissipation current
Symbol
ICC
Conditions
No input light
*3, Output terminal OPEN
*3, *4
MIN.
-
TYP.
MAX.
4.5
-
Unit
mA
V
2.8
High level output voltage
Low level output voltage
High level pulse width
Low level pulse width
B.P.F. center frequency
Linear ultimate distance
VOH
VOL
T1
VCC
-
0.2
-
-
0.45
0.6
800
800
-
V
*3
400
400
-
-
-
µ s
µ s
kHz
m
T2
fO
38
-
L
φ , θ = 0˚, Ee < 10 lx
5.0
-
(
)
φ = ± 30˚ θ = 0˚
Linear ultimate distance
L1
3.0
-
-
m
(
)
θ = ± 15˚ φ = 0˚ Ee < 10 lx
*3 The burst wave as shown in the following figure shall be transmitted.
*4 Pull-up resistance : 2.2kΩ
*5 By SHARP transmitter
fo= 38kHz, Duty 50%
Transmission
signal
600µs
600µs
Output
T2
T1
■Internal Block Diagram
Vout
Limiter
B.P.F.
Demodulator Integrator Comparator
Vcc
GND
IS1U60/IS1U60L
■ Performance
Using the transmitter shown in Fig. 1, the output signal of the light detecting unit is good enough to meet the following items in the standard optical system in Fig. 2.
(1) Linear reception distance characteristics
When L=0.2 to 5 m, Ee < 10 lx ( *4) and φ =0˚ in Fig. 2, the output signal shall meet the electrical characteristics in the attached list.
(2) Sensitivity angle reception distance characteristics
When L=0.2 to 3 m, Ee < 10 lx ( *4) and φ<= 30 ˚ in the direction X and θ =0˚ in the direction Y in Fig. 2,
the output signal shall meet the electrical characteristics in the attached lis.t Further, the electrical characteristics shall be met
when L=0.2 to 5 m, Ee < 10 lx (*4) and φ =0˚ in the direction X and θ<= 15˚ in the direction Y.
*4 It refers to detector face illuminance.
20cm
10kΩ
+ 5V
Transmitter (GL521 used)
Duty 50%
f
o = 38kHz
Vout
Oscilloscope
Fig. 1 Transmitter
In the above figure, the transmitter should be set so that the output Vout can be 40mVP - P
.
However, the PD49PI to be used here should be of the short-circuit current ISC =2.6 µ A at Ev=100 lx.
(Ev is an illuminance by CIE standard light source A (tungsten lamp).)
Direction Y
Direction X
External disturbing light
detector face illuminance : Ee
θ, φ
θ, φ
Vout
Reception distance : L
Transmitter
φ : Direction X
θ : Direction Y
Fig. 2 Standard optical system
IS1U60/IS1U60L
Fig. 1 B.P.F. Frequency Characteristics (TYP.)
Fig. 2 Sensitivity Angle (Direction X)
Characteristics (TYP.) for Reference
- 20˚
- 10˚
0˚
10˚
20˚
- 30˚
30˚
- 40˚
- 50˚
40˚
50˚
- 60˚
- 70˚
60˚
70˚
- 80˚
- 90˚
80˚
90˚
20
30
40
50
60
0
Angular displacement φ
Carrier frequency (kHz)
Fig. 3 Sensitivity Angle (Direction Y)
Characteristics (TYP.) for Reference
Fig. 4 Relative Reception Distance vs. Ambient
Temperature (TYP.) for Reference
120
- 20˚
- 10˚
0˚
10˚
20˚
- 30˚
30˚
100
80
- 40˚
- 50˚
40˚
50˚
60
40
20
0
SHARP
standard transmitter
Unit
- 60˚
- 70˚
60˚
70˚
Relative comparison with reception
distance at VCC=5V,φ =0˚ , Ee <10 lx
and Ta=25 ˚C taken as 100%
- 80˚
- 90˚
80˚
90˚
- 40 - 20
0
20
40
60
80
100
0
Angular displacement φ
Ambient temperature Ta (˚C)
Fig. 5 AEHA (Japan Association of Electrical Home Appliances)
Code Pulse Width Characteristics (1st Bit) (TYP.) for Reference
700
(Conditions)
600
Low level pulse width
Unit
AEHA code generating transmitter
500
400
VCC=5V, Ta=RT, φ =0˚ , Ee < 10 lx
300
High level pulse width
200
1st bit
100
0
T= 430µ s
0
1
2
3
4
5
6
7
8
9
10
Reception distance (m)
IS1U60/IS1U60L
Fig. 6 Spectral Sensitivity for Reference
100
Ta=25˚C
90
80
70
60
50
40
30
20
10
0
500
600
700
800
900
1000
1100
Wavelength λ (nm)
■ Precautions for Operation
(1) Use the light emitting unit (remote control transmitter), in consideration of performance, characteristics, operating conditions of
light emitting device and the characteristics of the light detecting unit.
(2) Pay attention to a malfunction of the light detecting unit when the surface is stained with dust and refuse.
Care must be taken not to touch the light detector surface.
• Conduct cleaning as follows.
(3) Cleaning
Solvent dip cleaning : Solvent temperature of 45 ˚C max., dipping time : Within 3 minutes
Ultrasonic cleaning : Elements are affected differently depending on the size of cleaning bath, ultrasonic output, time,
size of PWB and mounting method of elements.
Conduct trial cleaning on actual operating conditions in advance to make sure that no problem results.
• Use the following solvents only.
Solvents : Ethyl alcohol, methyl alcohol or isopropyl alcohol
(4) To avoid the electrostatic breakdown of IC, handle the unit under the condition of grounding with human body, soldering iron, etc.
(5) Do not apply unnecessary force to the terminal.
(6) Example of recommended external circuit (mount outer mounting parts near the sensor as much as possible.)
R1
Ve
VCC
+
(Circuit constant)
R1 = 47Ω ± 5%
C1 = 47µF
C1
IS1U60
GND
Vout
GND
Vout
相关型号:
IS1X-G
Optocoupler - Transistor Output, 1 CHANNEL TRANSISTOR OUTPUT OPTOCOUPLER, PLASTIC, DIP-6
ISOCOM
IS1X-SM
Optocoupler - Transistor Output, 1 CHANNEL TRANSISTOR OUTPUT OPTOCOUPLER, SURFACE MOUNT, PLASTIC, DIP-6
ISOCOM
IS1X-SMT&R
Optocoupler - Transistor Output, 1 CHANNEL TRANSISTOR OUTPUT OPTOCOUPLER, SURFACE MOUNT, PLASTIC, DIP-6
ISOCOM
IS1XG
Transistor Output Optocoupler, 1-Element, 5300V Isolation, ROHS COMPLIANT, PLASTIC, DIP-6
ISOCOM
IS1XSM
Transistor Output Optocoupler, 1-Element, 5300V Isolation, ROHS COMPLIANT, PLASTIC, SURFACE MOUNT PACKAGE-6
ISOCOM
IS1XSMT&R
Transistor Output Optocoupler, 1-Element, 5300V Isolation, ROHS COMPLIANT, PLASTIC, SURFACE MOUNT PACKAGE-6
ISOCOM
©2020 ICPDF网 联系我们和版权申明