Product data sheet
ATV610U30N4Z
Characteristics
variable speed drive ATV610, 3 kW, 380...460 V,
IP20, without keypad
Main
Range of product
Product or component type
Product specific application
Device short name
Variant
Easy Altivar 610
Variable speed drive
Fan, pump, compressor, conveyor
ATV610
Standard version
Product destination
Mounting mode
Asynchronous motors
Cabinet mount
EMC filter
Integrated conforming to EN/IEC 61800-3 category C3 with 50 m
IP degree of protection
Type of cooling
IP20
Forced convection
50...60 Hz +/-5 %
3 phases
Supply frequency
Network number of phases
[Us] rated supply voltage
Motor power kW
380...460 V - 15...10 %
3 kW for normal duty
2.2 kW for heavy duty
Motor power hp
Line current
4 hp for normal duty
3 hp for heavy duty
10.1 A at 380 V (normal duty)
8.4 A at 460 V (normal duty)
7.6 A at 380 V (heavy duty)
6.4 A at 460 V (heavy duty)
Prospective line Isc
Apparent power
5 kA
6.7 kVA at 460 V (normal duty)
5.1 kVA at 460 V (heavy duty)
Continuous output current
8.4 A at 4 kHz for normal duty
6.4 A at 4 kHz for heavy duty
Maximum transient current
Asynchronous motor control profile
7.9 A during 60 s (normal duty)
8.4 A during 60 s (heavy duty)
Constant torque standard
Variable torque standard
Optimized torque mode
Output frequency
0.0001…0.5 kHz
4 kHz
Nominal switching frequency
May 14, 2021
1
Switching frequency
Number of preset speeds
Communication port protocol
Option card
2...12 kHz adjustable
16 preset speeds
Modbus RTU
Slot A: communication card, Profibus DP V1
Slot A: digital or analog I/O extension card
Slot A: relay output card
Complementary
Output voltage
<= power supply voltage
Motor slip compensation
Adjustable
Automatic whatever the load
Not available in permanent magnet motor law
Can be suppressed
Acceleration and deceleration ramps
S, U or customized
Linear adjustable separately from 0.01 to 9000 s
Braking to standstill
Protection type
By DC injection
Thermal protection: motor
Motor phase break: motor
Thermal protection: drive
Overheating: drive
Overcurrent between output phases and earth: drive
Overload of output voltage: drive
Short-circuit protection: drive
Motor phase break: drive
Overvoltages on the DC bus: drive
Line supply overvoltage: drive
Line supply undervoltage: drive
Line supply phase loss: drive
Overspeed: drive
Break on the control circuit: drive
Frequency resolution
Electrical connection
Display unit: 0.1 Hz
Analog input: 0.012/50 Hz
Control, screw terminal: 0.5...1.5 mm²
Line side, screw terminal: 2.5...16 mm²
Motor, screw terminal: 2.5...16 mm²
Connector type
1 RJ45 (on lower part) for Modbus serial
2-wire RS 485 for Modbus serial
RTU for Modbus serial
Physical interface
Transmission frame
Transmission rate
Type of polarization
Number of addresses
Method of access
Supply
4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
No impedance for Modbus serial
1…247 for Modbus serial
Slave
External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-
circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection
type: overload and short-circuit protection
Local signalling
2 LEDs for local diagnostic
1 LED (yellow) for embedded communication status
2 LEDs (dual colour) for communication module status
1 LED (red) for presence of voltage
Width
130.0 mm
284.0 mm
196.0 mm
2.24 kg
3
Height
Depth
Net weight
Analogue input number
Analogue input type
AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits
AI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits
AI2, AI3 software-configurable temperature probe or water level sensor
Discrete input number
Discrete input type
6
DI1...DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm
DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
Input compatibility
2
DI1...DI6: logic input level 1 PLC conforming to EN/IEC 61131-2
DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
Discrete input logic
Positive logic (source): DI1...DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1)
Negative logic (sink): DI1...DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1)
Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
Analogue output number
Analogue output type
2
Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bits
Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits
Sampling duration
5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input
2 ms +/- 0.5 ms (DI1...DI6)configurable - discrete input
5 ms +/- 1 ms (DI5, DI6)configurable - pulse input
10 ms +/- 1 ms (AQ1, AQ2) - analog output
Accuracy
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Linearity error
AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
AQ1, AQ2: +/- 0.2 % for analog output
Relay output number
Relay output type
3
Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles
Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
Refresh time
Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
Relay output R1, R2, R3: 5 mA at 24 V DC
Minimum switching current
Maximum switching current
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Isolation
Between power and control terminals
Insulation resistance
> 1 MOhm 500 V DC for 1 minute to earth
Environment
Noise level
55 dB conforming to 86/188/EEC
Power dissipation in W
74 W(forced convection) at 380 V, switching frequency 4 kHz
29 W(natural convection) at 380 V, switching frequency 4 kHz
Operating position
Vertical +/- 10 degree
Electromagnetic compatibility
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Pollution degree
2 conforming to EN/IEC 61800-5-1
Vibration resistance
1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6
1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
Shock resistance
15 gn for 11 ms conforming to IEC 60068-2-27
Relative humidity
5…95 % without condensation conforming to IEC 60068-2-3
Ambient air temperature for operation
-15…45 °C (without derating)
45…60 °C (with derating factor)
Operating altitude
Environmental characteristic
Standards
<= 1000 m without derating
1000...4800 m with current derating 1 % per 100 m
Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3
Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
EN/IEC 61800-3
Environment 2 category C3 EN/IEC 61800-3
EN/IEC 61800-5-1
IEC 60721-3
Marking
CE
3