ATV610U30N4Z  
Characteristics  
variable speed drive ATV610, 3 kW, 380...460 V,  
IP20, without keypad  
Main  
Range of product  
Product or component type  
Product specific application  
Device short name  
Variant  
Easy Altivar 610  
Variable speed drive  
Fan, pump, compressor, conveyor  
ATV610  
Standard version  
Product destination  
Mounting mode  
Asynchronous motors  
Cabinet mount  
EMC filter  
Integrated conforming to EN/IEC 61800-3 category C3 with 50 m  
IP degree of protection  
Type of cooling  
IP20  
Forced convection  
50...60 Hz +/-5 %  
3 phases  
Supply frequency  
Network number of phases  
[Us] rated supply voltage  
Motor power kW  
380...460 V - 15...10 %  
3 kW for normal duty  
2.2 kW for heavy duty  
Motor power hp  
Line current  
4 hp for normal duty  
3 hp for heavy duty  
10.1 A at 380 V (normal duty)  
8.4 A at 460 V (normal duty)  
7.6 A at 380 V (heavy duty)  
6.4 A at 460 V (heavy duty)  
Prospective line Isc  
Apparent power  
5 kA  
6.7 kVA at 460 V (normal duty)  
5.1 kVA at 460 V (heavy duty)  
Continuous output current  
8.4 A at 4 kHz for normal duty  
6.4 A at 4 kHz for heavy duty  
Maximum transient current  
Asynchronous motor control profile  
7.9 A during 60 s (normal duty)  
8.4 A during 60 s (heavy duty)  
Constant torque standard  
Variable torque standard  
Optimized torque mode  
Output frequency  
0.0001…0.5 kHz  
4 kHz  
Nominal switching frequency  
May 14, 2021  
1
Switching frequency  
Number of preset speeds  
Communication port protocol  
Option card  
2...12 kHz adjustable  
16 preset speeds  
Modbus RTU  
Slot A: communication card, Profibus DP V1  
Slot A: digital or analog I/O extension card  
Slot A: relay output card  
Complementary  
Output voltage  
<= power supply voltage  
Motor slip compensation  
Adjustable  
Automatic whatever the load  
Not available in permanent magnet motor law  
Can be suppressed  
Acceleration and deceleration ramps  
S, U or customized  
Linear adjustable separately from 0.01 to 9000 s  
Braking to standstill  
Protection type  
By DC injection  
Thermal protection: motor  
Motor phase break: motor  
Thermal protection: drive  
Overheating: drive  
Overcurrent between output phases and earth: drive  
Overload of output voltage: drive  
Short-circuit protection: drive  
Motor phase break: drive  
Overvoltages on the DC bus: drive  
Line supply overvoltage: drive  
Line supply undervoltage: drive  
Line supply phase loss: drive  
Overspeed: drive  
Break on the control circuit: drive  
Frequency resolution  
Electrical connection  
Display unit: 0.1 Hz  
Analog input: 0.012/50 Hz  
Control, screw terminal: 0.5...1.5 mm²  
Line side, screw terminal: 2.5...16 mm²  
Motor, screw terminal: 2.5...16 mm²  
Connector type  
1 RJ45 (on lower part) for Modbus serial  
2-wire RS 485 for Modbus serial  
RTU for Modbus serial  
Physical interface  
Transmission frame  
Transmission rate  
Type of polarization  
Number of addresses  
Method of access  
Supply  
4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial  
No impedance for Modbus serial  
1…247 for Modbus serial  
Slave  
External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-  
circuit protection  
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection  
type: overload and short-circuit protection  
Local signalling  
2 LEDs for local diagnostic  
1 LED (yellow) for embedded communication status  
2 LEDs (dual colour) for communication module status  
1 LED (red) for presence of voltage  
Width  
130.0 mm  
284.0 mm  
196.0 mm  
2.24 kg  
3
Height  
Depth  
Net weight  
Analogue input number  
Analogue input type  
AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits  
AI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits  
AI2, AI3 software-configurable temperature probe or water level sensor  
Discrete input number  
Discrete input type  
6
DI1...DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm  
DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)  
Input compatibility  
2
DI1...DI6: logic input level 1 PLC conforming to EN/IEC 61131-2  
DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68  
Discrete input logic  
Positive logic (source): DI1...DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1)  
Negative logic (sink): DI1...DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1)  
Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)  
Analogue output number  
Analogue output type  
2
Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bits  
Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits  
Sampling duration  
5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input  
2 ms +/- 0.5 ms (DI1...DI6)configurable - discrete input  
5 ms +/- 1 ms (DI5, DI6)configurable - pulse input  
10 ms +/- 1 ms (AQ1, AQ2) - analog output  
Accuracy  
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input  
+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output  
Linearity error  
AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input  
AQ1, AQ2: +/- 0.2 % for analog output  
Relay output number  
Relay output type  
3
Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles  
Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles  
Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles  
Refresh time  
Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)  
Relay output R1, R2, R3: 5 mA at 24 V DC  
Minimum switching current  
Maximum switching current  
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC  
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC  
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC  
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC  
Isolation  
Between power and control terminals  
Insulation resistance  
> 1 MOhm 500 V DC for 1 minute to earth  
Environment  
Noise level  
55 dB conforming to 86/188/EEC  
Power dissipation in W  
74 W(forced convection) at 380 V, switching frequency 4 kHz  
29 W(natural convection) at 380 V, switching frequency 4 kHz  
Operating position  
Vertical +/- 10 degree  
Electromagnetic compatibility  
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2  
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3  
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4  
1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5  
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6  
Pollution degree  
2 conforming to EN/IEC 61800-5-1  
Vibration resistance  
1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6  
1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6  
Shock resistance  
15 gn for 11 ms conforming to IEC 60068-2-27  
Relative humidity  
5…95 % without condensation conforming to IEC 60068-2-3  
Ambient air temperature for operation  
-15…45 °C (without derating)  
45…60 °C (with derating factor)  
Operating altitude  
Environmental characteristic  
Standards  
<= 1000 m without derating  
1000...4800 m with current derating 1 % per 100 m  
Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3  
Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3  
EN/IEC 61800-3  
Environment 2 category C3 EN/IEC 61800-3  
EN/IEC 61800-5-1  
IEC 60721-3  
Marking  
CE  
3

相关型号:

ATV610U30N4Z

variable speed drive ATV610, 3 kW, 380...460 V, IP20, without keypad
SCHNEIDER

ATV61EXA2C90N4

enclosed variable speed drive ATV61 Plus - 900 kW - 400V - IP23
SCHNEIDER

ATV61EXA2M15Y

variable speed drive ATV61 Plus - 1500 kW - 690V - IP23
SCHNEIDER

ATV61EXA5C90N4

enclosed variable speed drive ATV61 Plus - 900 kW - 400V - IP54
SCHNEIDER

ATV61EXA5M13N4

enclosed variable speed drive ATV61 Plus - 1300 kW - 400V - IP54
SCHNEIDER

ATV61EXA5M18Y

variable speed drive ATV61 Plus - 1800 kW - 690V - IP54
SCHNEIDER

ATV61EXA5M21Y

variable speed drive ATV61 Plus - 2100 kW - 690V - IP54
SCHNEIDER

ATV61EXA5M24Y

variable speed drive ATV61 Plus - 2400 kW - 690V - IP54
SCHNEIDER

ATV622

14 PIN DIP HCMOS TCXO
CONNOR-WINFIE

ATV630C22N4MN

HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
SCHNEIDER

ATV630C31N4CMN

HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
SCHNEIDER

ATV630C31N4MN

HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
SCHNEIDER