Product data sheet
ATV61EXA5C90N4
Characteristics
enclosed variable speed drive ATV61 Plus - 900
kW - 400V - IP54
Commercial status
To be discontinued on: 31 December 2023
To be end-of-service on: 31 December 2031
To be discontinued
Main
Range of product
Product or component type
Device short name
Product destination
Altivar 61 Plus
Variable speed drive
ATV61
Asynchronous motors
Synchronous motors
Product specific application
Assembly style
Pumping and ventilation machine
In floor-standing enclosure with separate air flows
Product composition
Terminals/bars for motor connection
A plinth
A wired ready-assembled Sarel Spacial 6000 enclosure
Integrated drive system ATV61EC90N4E1
Control transformer for 230 V
A switch and fast-acting fuses
An IP65 remote mounting kit for graphic display terminal
EMC filter
Integrated
Network number of phases
Rated supply voltage
Supply frequency
Motor power kW
3 phases
380...415 V +/- 10 %
50...60 Hz
900 kW, 3 phases at 380...415 V
1512 A at 400 V3 phases / 900 kW
IP54
Line current
IP degree of protection
Complementary
Apparent power
1048 kVA for 400 V3 phases / 900 kW
100 kA with external fuses
1580 A at 2.5 kHz, 400 V3 phases
1896 A for 60 s 3 phases
0.1…500 Hz
Prospective line Isc
Continuous output current
Maximum transient current
Speed drive output frequency
Nominal switching frequency
Switching frequency
2.5 kHz
2...4.9 kHz adjustable
2.5...4.9 kHz with derating factor
Speed range
1…100 in open-loop mode, without speed feedback
Speed accuracy
+/- 10 % of nominal slip 0.2 Tn to Tn without speed feedback
May 18, 2021
1
Torque accuracy
+/- 15 % in open-loop mode, without speed feedback
Transient overtorque
120 % of nominal motor torque for 60 s
135 % of nominal motor torque for 2 s
Braking torque
30 % without braking resistor
<= 125 % with braking resistor
Asynchronous motor control profile
Voltage/frequency ratio, 2 points
Flux vector control without sensor, standard
Voltage/frequency ratio - Energy Saving, quadratic U/f
Voltage/frequency ratio, 5 points
Synchronous motor control profile
Regulation loop
Vector control without sensor, standard
Adjustable PI regulator
Motor slip compensation
Adjustable
Automatic whatever the load
Not available in voltage/frequency ratio (2 or 5 points)
Suppressable
Supply voltage limits
Network frequency limits
Overvoltage category
Local signalling
342…457 V
47.5…63 Hz
Class 3 conforming to EN 50178
LCD display unit for operation function, status and configuration
<= supply voltage
Output voltage
Isolation
Electrical between power and control
IEC cable at 40 °C, copper 70 °C / PVC
Type of cable for external connection
Electrical connection
Terminal - 2.5 mm² / AWG 14 0.6 N.m (R1A, R1B, R1C, R2A, R2B) entry from the bottom
Screw clamp terminals - 1.5 mm² 0.25 N.m (AI1-/AI1+, AI2, AO1, LI1...LI6, PWR) entry from the
bottom
Bar M12 - 16 x 240 mm² 41 N.m (L1/R, L2/S, L3/T) entry from the bottom at 6-pulse operation
Bar M12 - 8 x 240 mm² 41 N.m (L1/R, L2/S, L3/T) entry from the bottom at 12-pulse operation
Motor recommanded cable cross
section
6 (3 x 240) mm²
7 (3 x 185) mm²
Short-circuit protection
2000 A fuse protection type gI - power supply upstream - at 6-pulse operation
1000 A fuse protection type gI - power supply upstream - at 12-pulse operation
Supply
External supply: 24 V (19…30 V)DC, <1 A
Internal supply for reference potentiometer: 10 V (10…11 V)DC, <10 A
Internal supply: 24 V (21…27 V)DC, <100 A
Analogue input number
Analogue input type
2
AI2 software-configurable voltage: 0...10 V DC, 24 V max, impedance: 30 kOhm, sampling time:
1.5…2.5 ms, resolution: 11 bits
AI1-/Al1+ bipolar differential voltage: +/- 10 V DC, 24 V max, sampling time: 1.5…2.5 ms, resolution:
11 bits + sign
AI2 software-configurable current: 0...20 mA/4...20 mA, impedance: 250 Ohm, sampling time: 1.5…
2.5 ms, resolution: 11 bits
Analogue output number
Analogue output type
1
Software-configurable voltage: (AO1) 0...10 V DC - 500 Ohm - sampling time: 1.5…2.5 ms -
resolution: 10 bits
Software-configurable current: (AO1) 0...20 mA/4...20 mA - 500 Ohm - sampling time: 1.5…2.5 ms -
resolution: 10 bits
Discrete output number
Discrete output type
2
Configurable relay logic: (R1A, R1B, R1C)NO/NC - 6.5...7.5 ms - 100000 cycles
Configurable relay logic: (R2A, R2B)NO - 6.5...7.5 ms - 100000 cycles
Minimum switching current
Maximum switching current
3 mA at 24 V DC (configurable relay logic)
5 A at 250 V AC on resistive load - cos phi = 1 for configurable relay logic
5 A at 30 V DC on inductive load - L/R = 7 ms for configurable relay logic
5 A at 30 V DC on resistive load - L/R = 0 ms for configurable relay logic
5 A at 250 V AC on inductive load - cos phi = 0.4 for configurable relay logic
Discrete input number
Discrete input type
7
Programmable (LI1...LI5) at 24 V DC <= 30 V level 1 PLC 3.5 kOhm (duration=1.5…2.5 ms)
Switch-configurable (LI6) at 24 V DC <= 30 V level 1 PLC 1.5 kOhm (duration=1.5…2.5 ms)
Safety input (PWR) at 24 V DC <= 30 V 1.5 kOhm
Discrete input logic
Positive (LI1...LI6), 0...5 V (state 0), 11...30 V (state 1)
Negative (LI1...LI6), 16...30 V (state 0), 0...10 V (state 1)
Positive (PWR), 0...2 V (state 0), 17...30 V (state 1)
Acceleration and deceleration ramps
Linear adjustable separately from 0.01 to 9000 s
S, U or customized
2
Braking to standstill
Protection type
By DC injection, <60 s
Overheating protection: drive
Thermal protection: drive
Short-circuit between motor phases: drive
Input phase breaks: drive
Overcurrent between output phases and earth: drive
Overvoltages on the DC bus: drive
Break on the control circuit: drive
Against exceeding limit speed: drive
Line supply undervoltage: drive
Line supply overvoltage: drive
Against input phase loss: drive
Thermal protection: motor
Motor phase break: motor
Power removal: drive
Power removal: motor
Dielectric strength
3535 V DC between earth and power terminals
5092 V DC between control and power terminals
Insulation resistance
Frequency resolution
> 1 mOhm 500 V DC for 1 minute
Display unit: 0.1 Hz
Analog input: 0.024/50 Hz
Communication port protocol
Connector type
Modbus
CANopen
1 RJ45 (on front face) for Modbus
1 RJ45 (on terminal) for Modbus
Male SUB-D 9 on RJ45 for CANopen
Physical interface
Transmission frame
Transmission rate
2-wire RS 485 for Modbus
RTU for Modbus
9600 bps, 19200 bps for Modbus on front face
4800 bps, 9600 bps, 19200 bps, 38.4 Kbps for Modbus on terminal
20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps for CANopen
Data format
8 bits, 1 stop, even parity for Modbus on front face
8 bits, odd even or no configurable parity for Modbus on terminal
Type of polarization
Number of addresses
No impedance for Modbus
1…247 for Modbus
1…127 for CANopen
Method of access
Slave CANopen
Options for enclosure configuration
Safe standstill for power circuit
PTC relay for power circuit
Pt100 relay for power circuit
Insulation monitoring for power circuit
Design for IT networks for power circuit
External 230 V supply terminals for power circuit
Buffer voltage 24 V DC power supply for power circuit
Enclosure lighting for power circuit
Key switch (local/remote) for power circuit
Motor heating for power circuit
External motor fan for power circuit
Voltmeter for power circuit
Door handle for main switch for power circuit
Line contactor for power circuit
12-pulse supply for power circuit
Ammeter for power circuit
Enclosure heating for power circuit
Motor choke for power circuit
Cable entry via the top for power circuit
Enclosure plinth for power circuit
Relay output C/O for control circuit
External 24 V DC supply terminals for power circuit
Circuit breaker for power circuit
Line reactor for power circuit
Control terminals for control circuit
Adaptor for 115 V logic inputs for control circuit
Isolated amplifier for control circuit
Option card
Communication card for Modbus TCP/IP
Communication card for Fipio
Communication card for Modbus/Uni-Telway
Communication card for Modbus Plus
Communication card for EtherNet/IP
3
Communication card for DeviceNet
Communication card for Profibus DP
Communication card for Profibus DP V1
Communication card for Interbus-S
Communication card for CC-Link
Communication card for LonWorks
Communication card for METASYS N2
Communication card for APOGEE FLN
Communication card for BACnet
Basic I/O extension card
Extended I/O extension card
Controller inside programmable card
Multi-pump card
Encoder interface cards
Operating position
Colour of enclosure
Colour of base of enclosure
Width
Vertical +/- 10 degree
Light grey (RAL 7035)
Dark grey (RAL 7022)
3400 mm
Height
2009 mm
Depth
642 mm
Net weight
1925 kg
Environment
Electromagnetic compatibility
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Standards
EN 55011 class A group 2
EN/IEC 61800-5-1
EN 61800-3 environments 1 category C3
EN/IEC 61800-3
EN 61800-3 environments 2 category C3
Product certifications
ATEX
GOST
Marking
CE
Pollution degree
Noise level
3 conforming to EN/IEC 61800-5-1
79 dB
Vibration resistance
1.5 mm (f= 3…10 Hz) conforming to EN/IEC 60068-2-6
0.6 gn (f= 10…200 Hz) conforming to EN/IEC 60068-2-6
3M3 conforming to EN/IEC 60721-3-3
Shock resistance
4 gn for 11 ms conforming to EN/IEC 60068-2-27
3M2 conforming to EN/IEC 60721-3-3
Environmental characteristic
3C2 without condensation conforming to IEC 60721-3-3
3S2 without condensation conforming to IEC 60721-3-3
3K3 without condensation conforming to IEC 60721-3-3
Relative humidity
0…95 %
Ambient air temperature for operation
0…40 °C (without derating)
40…50 °C (with current derating 1.5 % per °C)
Ambient air temperature for storage
Volume of cooling air
-25…70 °C
11000 m3/h
Operating altitude
<= 1000 m without derating
1000...3000 m with current derating 1 % per 100 m
Packing Units
Package 1 Weight
Package 1 Height
Package 1 width
Package 1 Length
1850.000 kg
20.000 dm
6.600 dm
34.400 dm
4
Contractual warranty
Warranty
18 months
5
Product data sheet
ATV61EXA5C90N4
Dimensions Drawings
IP 23 Floor-Standing Enclosure with Separate Air Flows
Dimensions
NOTE: For each floor-standing enclosure added, allow a 4 mm/0.15 in. space for the seal.
6
Product data sheet
ATV61EXA5C90N4
Connections and Schema
Floor-Standing Enclosure with Separate Air Flows
Standard 6-pulse Design
A1
A2
F1
IL1
KM1
M
Q1
(1)
(2)
(3)
(4)
(5)
(6)
Drive
Enclosure
Fuses
Optional line choke
Optional line contactor
Motor
Switch
Filter
Control
Relay control
Reference potentiometer
PLC
Optional motor choke
7
Optional 12-pulse Design
A1
A2
F1
IL1
KM1
M
Q1
(1)
(2)
(3)
(4)
(5)
(6)
Drive
Enclosure
Fuses
Optional line choke
Optional line contactor
Motor
Switch
Filter
Control
Relay control
Reference potentiometer
PLC
Optional motor choke
8
Product data sheet
ATV61EXA5C90N4
Performance Curves
IP 23 Floor-Standing Enclosure with Separate Air Flows
Derating Curves
The derating curves for the drive nominal current (In) are dependent on the temperature and switching frequency. For intermediate temperatures,
interpolate between 2 curves.
NOTE: The drive will reduce the switching frequency automatically in the event of excessive temperature rise.