Tel.X Battery rack systems
Standard rack
Saft’s rack systems, together with Tel.X high energy density batteries, provide a robust, lighter and
reliable battery back-up solution for multiple types of telecom applications.
The modular and scalable solution systems
are available in two voltage ranges: 24 V
and 48 V systems. Available in standard
19” and 23’’ rack, the systems are custom
fit for the overall Tel.X battery range. The
systems are capable to host up to 5 each
48
V battery strings per rack. This
combination allows for accrued flexibility
of both foot print and back-up capacity
range most suitable for deployment in
demanding indoor environments.
Cable harnesses and bus bar
With these systems, Saft is able to provide
a turnkey solution which significantly
reduces the floor loading compared to
VRLA.
System features
ꢀ■
Based on standard frame width: 19” or
23”
ꢀ■
Available in 2 versions: 24 V or 48 V
Integrated bus bar(s) with polycarbonate
Saft’s rack systems are delivered pre-
assembled and pre-wired.
ꢀ■
cover(s)
ꢀ■
Pre-wired with: Direct Connect or SB 50
Anderson quick connect
Modular and scalable: up to 5 each 48 V
battery strings per system (or 10 each
24 V battery strings)
Scalable back-up power: from 3.6 kWh
up to 41 kWh
All levels are liquid tight
Painted grey using durable epoxy
Applications
ꢀ■
ꢀ■
For wireline and wireless applications
such as:
• CEV, hut and shelter
• BTS (base stations)
• Central Office
ꢀ■
ꢀ■
• Customer premises
ꢀ■
powder-coat
ꢀ■
Template for anchoring pattern provided
System benefits
ꢀ■
Tel.X battery
Saft’s Tel.X battery is a proven solution
designed specifically for telecom
applications.
Compact, optimized and integrated
solution
ꢀ■
Significant reduction in floor loading
compared to VRLA (15 % to 40 %)
Pre-assembled and pre-wired for rapid
ꢀ■
ꢀ■
Long life
High reliability
Maintenance-free
High energy density
installation
Flexible in voltage, capacity, dimensions
ꢀ■
ꢀ■
ꢀ■
and connections to answer individual
customer’s needs
Increased operational reliability
ꢀ■
ꢀ■
NEBS certified
ꢀ■
Battery capacities and floor loading for the standard rack systems
19" rack system without batteries
Battery model
Rack weight without batteries
Rack dimensions
48 V [kg] 48 V [lbs] 24 V [kg] 24 V [lbs]
W [cm]
52
W [in]
20.5
20.5
20.5
20.5
D [cm]
42
D [in]
16.5
20.5
28.0
33.5
H [cm]
213
H [in]
84
TLX 8O
104
113
127
132
230
250
280
290
122
132
145
150
270
290
320
330
TLX 100
TLX 150
TLX 180
52
52
52
52
71
85
213
213
213
84
84
84
19" rack system with batteries
Battery model
C8 Ah/ Max Wh/
Floor
Floor
Rack weight with batteries
Number of strings
string
string
loading
loading
48 V
24 V
10
[kg/m2]
2400
2208
2248
2150
[lbs/ft2]
492
48 V [kg] 48 V [lbs] 24 V [kg] 24 V [lbs]
TLX 8O
506
581
814
934
1115
1280
1795
2060
524
599
832
953
1155
1320
1835
2100
5
5
5
5
75
97
18000
23280
33600
41280
TLX 100
TLX 150
TLX 180
10
452
460
440
10
140
172
10
The floor loading data is calculated based on the full system load.
23" rack system without batteries
Battery model
Rack weight without batteries
Rack dimensions
48 V [kg] 48 V [lbs] 24 V [kg] 24 V [lbs]
W [cm]
62
W [in]
24.5
24.5
24.5
24.5
D [cm]
38
D [in]
15.0
16.5
22.5
26.7
H [cm]
213
H [in]
84
TLX 8O
109
118
132
136
240
260
290
300
127
136
150
154
280
300
330
340
TLX 100
TLX 150
TLX 180
62
62
62
42
57
68
213
213
213
84
84
84
23" rack system with batteries
Battery model
C8 Ah/ Max Wh/
Floor
Floor
Rack weight with batteries
Number of strings
string
string
loading
loading
48 V
24 V
10
[kg/m2]
2258
2460
2360
2246
[lbs/ft2]
462
48 V [kg] 48 V [lbs] 24 V [kg] 24 V [lbs]
TLX 8O
517
624
821
930
1140
1375
1810
2050
535
642
839
948
1180
1415
1850
2090
5
5
5
5
75
97
18000
23280
33600
41280
TLX 100
TLX 150
TLX 180
10
504
483
460
10
140
172
10
The floor loading data is calculated based on the full system load.
Notes
1. Use provided information to insure proper floor loadings are respected. Review building codes and respect proper engineering practices
before installing the battery rack systems. Always consider fully loaded battery rack systems when evaluating floor loadings.
2 Anchoring mechanism and grounding straps are not provided with the rack systems. Anchoring and grounding shall be done in
accordance with all applicable and required company as well as local, state and federal codes.
3. Saft is not liable or responsible for the improper installation of the rack systems.
Saft
Doc. No 21808-2-0811
Information in this document is subject to change without notice
and becomes contractual only after written confirmation by Saft.
Industrial Battery Group
12, rue Sadi Carnot
Published by the Communications Department.
93170 Bagnolet - France
Photo credit: Saft
Tel. : +33 1 49 93 19 18
Société par Actions Simplifiée au capital de 31 944 000 €
Fax : +33 1 49 93 19 64
RCS Bobigny B 383 703 873
www.saftbatteries.com
Produced in the UK by Arthur Associates Limited
相关型号:
©2020 ICPDF网 联系我们和版权申明