BP5062A5_10 [ROHM]

Non-Isolated AC/DC Converter; 非隔离式AC / DC转换器
BP5062A5_10
型号: BP5062A5_10
厂家: ROHM    ROHM
描述:

Non-Isolated AC/DC Converter
非隔离式AC / DC转换器

转换器
文件: 总4页 (文件大小:1018K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Data Sheet  
100VAC Input/5V (500mA) Output  
Non-Isolated AC/DC Converter  
BP5062A5  
Absolute Maximum Ratings  
Dimensions (Unit : mm)  
9.9MAX.  
Parameter  
Input voltage  
Symbol  
Vi  
Limits  
195  
Unit  
V
34.5MAX.  
Output current  
Io  
500  
mApk  
ESD endurance  
Vsurge  
Topr  
Tstg  
2
kV  
°C  
°C  
1
3
5
7
8
10  
12  
Operating temperature range  
Storage temperature range  
20 to +80  
25 to +105  
0.25 0.05  
0.5 0.1  
P=5.08 0.2  
2.54 11=27.94  
1.3 0.2  
5.05MAX.  
4.85MAX.  
3.3MAX  
Electrical Characteristics  
Parameter  
Input voltage range  
Output voltage  
Output current  
Line regulation  
Load regulation  
Output ripple voltage  
Power conversion efficiency  
Symbol Min.  
Typ.  
Max.  
195  
5.3  
500  
0.2  
0.3  
0.3  
Unit  
Conditions  
DC (80 to 137VAC)  
Vi=141V, Io=500mA  
Vi=141V  
Derating Curve  
113 141  
4.7  
0
V
V
mA  
V
V
Vp-p  
Vi  
Vo  
Io  
Derating Curve  
600  
5.0  
0.05  
0.07  
0.15  
69  
500  
400  
1  
2  
300  
60  
Vr  
Vl  
Vp  
η
Vi=−  
113V to  
195V, Io=500mA  
Operation Range  
200  
100  
0
Vi=141V, Io=0 to 500mA  
Vi=141V, Io=500mA  
Vi=141V, Io=500mA  
-30 -20 -10  
0 10 20 30 40 50 60 70 80 90  
%
Ambient Temperature Ta(°C)  
1 Maximum output current varies depending on ambient temperature ; please refer to derating curve.  
2 Spike noise is not included in output ripple voltage.  
Conversion Efficiency  
Conversion Efficiency  
(Ta=25°C, Vi=141V)  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
Application Circuit  
Function  
Output terminal Vo(5V)  
Not used  
Coil connect  
Not used  
Coil connect  
Not used  
COMMON  
Pin No.  
1
2
3
4
5
6
7
8
9
BP5062A5  
Please note that pin No.12  
side is input.  
0
100  
200  
300  
400  
500  
COMMON  
Not used  
Output Current Io(mA)  
12 10 8 7  
F2UASE  
5
3
1
10 N.C.  
11 Not used  
12 Input terminal Vi(141VDC  
R1  
4.71/4W  
Load Regulation  
)
D1  
Output  
5V  
1SR139-400  
Load Regulation  
L1  
220µH  
(Ta=25°C, Vi=141V)  
C2  
C3  
Input  
AC100V  
50Hz/60Hz  
+
6
ZNR  
220V  
C1  
0.22µF  
+
470µF/25V  
22µF/200V  
5
4
3
2
Be sure to use fuse for safety.  
Please verify operation and characteristics in the customer's circuit before actual usage.  
Ensure that the load current does not exceed the maximum rating.  
1
0
0
100 200 300 400 500 600 700 800  
Output Current Io(mA)  
External Component Specifications  
Surface Temperature Increase  
FUSE: FUSE  
Use a quick-acting fuse of 2.0A.  
Surface Temperature Increase  
C1: Input capacitor  
Rated voltage : More than 250V, Capacity : 22 to 100µF  
(Ta=25°C, Vi=141V)  
60  
Rated voltage : More than 250V  
Film or ceramic capacitor  
Capacitance : 0.1 to 0.22µF  
C2: Noise removal  
capacitor  
50  
40  
30  
20  
C3: Output capacitor  
Rated voltage : More than 16V, Capacitance : 220 to 820µF  
Low impedance type, ESR : Less than 0.25Ω  
Rated ripple current : More than 0.4Arms  
Evaluate under actual conditions since it affects the output  
ripple voltage.  
10  
0
0
100 200 300 400 500 600 700 800  
Output Current Io(mA)  
L1: Choke coil  
Inductance : 220µH, Rated current : More than 1.3A  
R1: Noise removal resistor Resistance : 4.7 to 10, Power : More than 1/4W  
D1: Rectifier diode  
Peak reverse voltage : More than 400V  
Mean rectifying current : More than 1.0A  
Peak forward surge current : More than 40A  
Full-wave rectification can be used.  
ZNR: Varistor  
A varistor is required to protect against lightning surges and  
static electricity.  
www.rohm.com  
©2010 ROHM Co., Ltd. All rights reserved.  
2010.01 - Rev.A  
1/1  
Notice  
N o t e s  
No copying or reproduction of this document, in part or in whole, is permitted without the  
consent of ROHM Co.,Ltd.  
The content specified herein is subject to change for improvement without notice.  
The content specified herein is for the purpose of introducing ROHM's products (hereinafter  
"Products"). If you wish to use any such Product, please be sure to refer to the specifications,  
which can be obtained from ROHM upon request.  
Examples of application circuits, circuit constants and any other information contained herein  
illustrate the standard usage and operations of the Products. The peripheral conditions must  
be taken into account when designing circuits for mass production.  
Great care was taken in ensuring the accuracy of the information specified in this document.  
However, should you incur any damage arising from any inaccuracy or misprint of such  
information, ROHM shall bear no responsibility for such damage.  
The technical information specified herein is intended only to show the typical functions of and  
examples of application circuits for the Products. ROHM does not grant you, explicitly or  
implicitly, any license to use or exercise intellectual property or other rights held by ROHM and  
other parties. ROHM shall bear no responsibility whatsoever for any dispute arising from the  
use of such technical information.  
The Products specified in this document are intended to be used with general-use electronic  
equipment or devices (such as audio visual equipment, office-automation equipment, commu-  
nication devices, electronic appliances and amusement devices).  
The Products specified in this document are not designed to be radiation tolerant.  
While ROHM always makes efforts to enhance the quality and reliability of its Products, a  
Product may fail or malfunction for a variety of reasons.  
Please be sure to implement in your equipment using the Products safety measures to guard  
against the possibility of physical injury, fire or any other damage caused in the event of the  
failure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHM  
shall bear no responsibility whatsoever for your use of any Product outside of the prescribed  
scope or not in accordance with the instruction manual.  
The Products are not designed or manufactured to be used with any equipment, device or  
system which requires an extremely high level of reliability the failure or malfunction of which  
may result in a direct threat to human life or create a risk of human injury (such as a medical  
instrument, transportation equipment, aerospace machinery, nuclear-reactor controller, fuel-  
controller or other safety device). ROHM shall bear no responsibility in any way for use of any  
of the Products for the above special purposes. If a Product is intended to be used for any  
such special purpose, please contact a ROHM sales representative before purchasing.  
If you intend to export or ship overseas any Product or technology specified herein that may  
be controlled under the Foreign Exchange and the Foreign Trade Law, you will be required to  
obtain a license or permit under the Law.  
Thank you for your accessing to ROHM product informations.  
More detail product informations and catalogs are available, please contact us.  
ROHM Customer Support System  
http://www.rohm.com/contact/  
www.rohm.com  
© 2010 ROHM Co., Ltd. All rights reserved.  
R1010  
A

相关型号:

BP5062A_10

Non-Isolated AC/DC Converter
ROHM

BP5063-5

AC100V input, 5V/200mA output
ROHM

BP5063-5_10

Non-Isolated AC/DC Converter
ROHM

BP5064

Analog IC
ETC

BP5065C

AC/DC converter AC100V input, −12V/90mA output
ROHM

BP5065C5

AC100V input, −5V/100mA output
ROHM

BP5067-12

AC/DC CONVERTER
ROHM

BP5067-12_10

Non-Isolated AC/DC Converter
ROHM

BP5067-15

AC100V input, 15V/300mA output
ROHM

BP5067-15_10

Non-Isolated AC/DC Converter
ROHM

BP5068

レギュレータLSI
ETC

BP5068-15

AC/DC converter - AC100V input, -15V/800mA output
ROHM