FIREBLADE-TX4 [RFSOLUTIONS]

RADIO REMOTE CONTROL SYSTEMS; 无线电遥控系统
FIREBLADE-TX4
型号: FIREBLADE-TX4
厂家: RFSOLUTIONS.LTD    RFSOLUTIONS.LTD
描述:

RADIO REMOTE CONTROL SYSTEMS
无线电遥控系统

遥控 远程控制 无线
文件: 总6页 (文件大小:1097K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
FIRE  
FLY  
R
ADIO REMOTE CONTROL SYSTEMS  
FIRE  
BLADE  
Applications  
Features  
Lighting Control  
1,2,4 or 8 Channel Systems  
12 / 24Vdc or 230Vac Supply  
Range  
General Purpose Remote Switching  
Industrial remote Switching  
Access Control  
FireFly up to 100 metres  
FireBlade up to 1,000 metres  
Description  
A Range of general purpose remote control systems  
Reliable FM Technology  
High Security RF Protocol  
‘Easy Learn’ Tx Encoder Feature  
Installation simply requires connections to power  
supply and the output relay screw terminals. The  
output relays are activated by the button press on the  
transmitter encoder.  
Easy Installation Via Screw Terminals.  
4 Relays 6A @ 230Vac  
Housed in a rugged IP68 weatherproof enclosure, the  
receiver has the capacity to learn up to 15 transmitter  
button pairings. These are memorised even if the  
power is removed.  
Each individual switch on each of the transmitters  
may be paired with any or all of the receiver relay  
outputs.  
Momentary / Latch / Timed Outputs  
Timed Output Adjustable 0 To 5 mins  
Any Switch ‘Maps to Any Relay Output  
Receiver Rated IP68  
The decoder is supplied in an IP68 rated enclosure  
with Cable Gland and wall mounting lugs.  
Versatile operation modes: Many to  
Many, One to Many, Many to One.  
DSFIREFLY-3 March 08  
2008 REG No 277 4001, ENGLAND.  
Page 1  
FIRE  
FLY  
R
ADIO  
REMOTE CONTROL SYSTEMS  
FIRE  
BLADE  
FireFly Systems LOS Range 100m  
Freq  
(MHz)  
Range**  
(Metres)  
Part Number  
Description  
FM RC System 1 ch  
FM RC System 2 ch  
FM RC System 4 ch  
433.92  
433.92  
433.92  
100  
100  
100  
FIREFLY-S1  
FIREFLY-S2  
FIREFLY-S4  
Additional FireFly Transmitters  
Freq  
(MHz)  
Range**  
(Metres)  
Part Number  
Description  
Transmitter 1 switch  
Transmitter 2 switch  
Transmitter 4 switch  
Transmitter 8 switch  
FIREFLY-TX1  
FIREFLY-TX2  
FIREFLY-TX4  
FIREFLY-TX8  
433.92  
433.92  
433.92  
433.92  
100  
100  
100  
100  
FIREFLY-TX-IPKIT Belt Clip and ’O’ Ring, Seals Transmitter to IP67  
FireBlade Systems LOS Range 1,000m  
Freq  
(MHz)  
Range**  
(Metres)  
Part Number  
Description  
FM RC System 1 ch  
FM RC System 2 ch  
FM RC System 4 ch  
434.525  
434.525  
434.525  
1,000  
1,000  
1,000  
FIREBLADE-S1  
FIREBLADE-S2  
FIREBLADE-S4  
Additional FireBlade Transmitters  
Part Number  
Freq  
(MHz)  
Range**  
(Metres)  
Description  
Transmitter 1 switch  
Transmitter 2 switch  
Transmitter 4 switch  
Transmitter 8 switch  
FIREBLADE-TX1  
FIREBLADE-TX2  
FIREBLADE-TX4  
FIREBLADE-TX8  
434.525  
434.525  
434.525  
434.525  
1,000  
1,000  
1,000  
1,000  
FIREFLY-TX-IPKIT Belt Clip and ’O’ Ring, Seals Transmitter to IP67  
** Range stated is optimum, direct line of sight. In worst conditions this can be reduced significantly.  
Custom Options  
These systems may be supplied as OEM units. Both transmitter and receiver use overlay stickers as part of  
the assembly which may easily be customised to incorporate any other logo etc. Please contact our sales  
dept for further information.  
DSFIREFLY-3 March 08  
2008 REG No 277 4001, ENGLAND.  
Page 2  
FIRE  
FLY  
R
ADIO REMOTE CONTROL SYSTEMS  
FIRE  
BLADE  
Power Supply  
This unit is designed to be a fixed installation, operated from either 12/24Vdc or 230Vac. Under no  
circumstances should the receiver be connected to more than one supply. Before removing the cover  
ensure that the mains input supply is isolated. Maintenance to the product that involves removal of the  
cover should only be carried out by a competent person or qualified electrician.  
Data Outputs  
Each output relay provides an isolated switch. Connections are Common (COM), Normally Open (NO) and  
Normally Closed (NC).  
Relay Connections when  
Transmitter NOT Operating  
Relay Connections when  
Transmitter OPERATING  
Connecting a Relay output to an Application  
Below is a simple example showing one possible way to wire a relay in order to give switched power to an  
external load:  
105 RECEIVER UNIT  
When the relay is energised the ‘COM’ connects to ’NO’  
and power is applied to the Load.  
N.C.  
RELAY OUTPUT  
1
0V+12V  
COM  
N.O.  
+12V  
0V  
LOAD  
+12V  
0V  
SUPPLY  
Pairing a Transmitter to a Receiver  
Each transmitter has a unique identity. Each time a switch is pressed, the transmitter emits a highly secure RF  
signal (appears as a random encrypted data stream). The Receiver can learn this encrypted signal and allocate  
to an output.  
Any transmitter switch may be paired to one or many of the receiver’s outputs, or a transmitter single switch  
may be paired to any number of receiver’s outputs to enable a powerful and flexible remote control system.  
The only limitation is that each receiver has a maximum capacity of 15 pairings, these can be from the same or  
any number of transmitters.  
Hint: the same transmitter may be taught to any number of receivers to create ‘master keys’.  
DSFIREFLY-3 March 08  
2008 REG No 277 4001, ENGLAND.  
Page 3  
FIRE  
FLY  
R
ADIO REMOTE CONTROL SYSTEMS  
FIRE  
BLADE  
To learn a new transmitter switch follow this procedure  
Any transmitter button can be learnt to one or many of the receiver output relays.  
Each button must be learnt to each relay individually by following this procedure:  
1.  
To select the receiver output relay to learn to:  
a. Briefly press the receiver Learn switch (SW1) once  
b. The Learn LED will flash once to indicate output relay 1 is selected  
c. After the LED stops flashing, press the Learn switch again to select the next relay channel  
d. Repeat step c until the required output relay is selected.  
2.  
3.  
4.  
5.  
Press the button on the transmitter you want to learn to the relay output.  
The Learn LED will then illuminate, press the same transmitter button again.  
The Learn LED will then flash to indicate learning is complete.  
To test the operation, press the transmitter button again and you will hear the relay ‘click’ as it operates.  
Erasing Receivers Memory  
1. Press and hold the receiver Learn Switch for approx 10 seconds.  
2. When the Learn LED turns OFF all memory is erased  
3. This is factory default state which is indicated by all output LED’s flashing together.  
NOTE: You cannot erase individual Tx encoders  
Receiver Outputs  
The jumper links configure the outputs to be Momentary, Latching or Timed.  
The jumper links are made / removed by a small link ‘cap’ placed over the pin header.  
Jumper Links  
Outputs 2 - 4  
(LK2 - 4)  
Open  
Mom (The Output operates for as long as the transmitter switch is held on)  
Latch (The Output changes state each time the Transmitter is operated)  
Connected  
LK0  
LK1  
Relay Outputs  
Open  
Open  
Output 1 Momentary  
Open  
Connected  
Open  
Output 1 Latching  
Connected  
Connected  
All Outputs fixed to ½ Second Momentary o/p  
Output 1, 0 to 5 minutes using Timer selection Potentiometer.  
Connected  
DSFIREFLY-3 March 08  
2008 REG No 277 4001, ENGLAND.  
Page 4  
FIRE  
FLY  
R
ADIO REMOTE CONTROL SYSTEMS  
FIRE  
BLADE  
Technical Specifications  
Transmitters : FireFly, FireBlade  
Enclosure Rating:  
Standard  
With IPKit  
IP40 (TBC)  
IP65 (TBC)  
Battery Type:  
Dimensions:  
CR2032 (supplied)  
90 x 54 x 27 mm (Note: FireBlade is supplied with external Antenna)  
Electrical Characteristics  
Supply Voltage  
Supply Current  
Min  
Typical  
Max  
Units  
V
mA  
3V  
Frequency:  
FireFLY: Wideband  
FireBLADE: Narrowband  
RF Output Power (ERP) @ 433 MHz  
432.90  
434.450  
-
433.920  
434.525  
3
434.10  
434.600  
10  
MHz  
mW  
Receiver Decoder  
Enclosure Rating  
Dimensions  
IP68  
169 x 132 x 85mm (not including antenna)  
-10 to +70o Celsius.  
Storage Temperature:  
Operating Temperature:  
0 to +55o Celsius.  
ELECTRICAL CHARACTERISTICS  
Supply Voltage for +12 v  
Supply Voltage for +24 v  
MIN  
10  
TYPICAL  
12.0  
24.0  
230  
MAX  
16  
28  
DIMENSION  
Vdc  
Vdc  
Vac  
A
22  
Supply Voltage for 230Vac  
Relay Rating* (230Vac) RLY1-4  
5
16  
140  
12  
Supply Current :  
Quiescent  
All relays operating*  
mA  
mS  
MS  
Time delay from Tx on Switch to Rx Relay operation  
Time delay from Tx sw relax to Rx Relay release  
100  
300  
*The relay contacts in this unit are for functional use only and must not be used for isolation purposes  
DSFIREFLY-3 March 08  
2008 REG No 277 4001, ENGLAND.  
Page 5  
FIRE  
FLY  
R
ADIO REMOTE CONTROL SYSTEMS  
FIRE  
BLADE  
Receiver Mechanical Dimensions  
R F Solutions Ltd.,  
Unit 21, Cliffe Industrial Estate,  
Lewes, E. Sussex. BN8 6JL. England.  
Email : sales@rfsolutions.co.uk  
http://www.rfsolutions.co.uk  
Tel: +44 (0)1273 898 000  
Fax: +44 (0)1273 480 661  
Information contained in this document is believed to be accurate, however no representation or warranty is given and no liability is assumed by R.F. Solutions Ltd. with respect to the accuracy of  
such information. Use of R.F.Solutions as critical components in life support systems is not authorised except with express written approval from R.F.Solutions Ltd.  
DSFIREFLY-3 March 08  
2008 REG No 277 4001, ENGLAND.  
Page 6  

相关型号:

FIREBLADE-TX8

RADIO REMOTE CONTROL SYSTEMS
RFSOLUTIONS

FIREFLY-S1

RADIO REMOTE CONTROL SYSTEMS
RFSOLUTIONS

FIREFLY-S2

RADIO REMOTE CONTROL SYSTEMS
RFSOLUTIONS

FIREFLY-S4

RADIO REMOTE CONTROL SYSTEMS
RFSOLUTIONS

FIREFLY-TX-IPKIT

RADIO REMOTE CONTROL SYSTEMS
RFSOLUTIONS

FIREFLY-TX-IPKIT

VIPER Remote Control Systems
RFMD

FIREFLY-TX1

RADIO REMOTE CONTROL SYSTEMS
RFSOLUTIONS

FIREFLY-TX1

VIPER Remote Control Systems
RFMD

FIREFLY-TX16

VIPER Remote Control Systems
RFMD

FIREFLY-TX2

RADIO REMOTE CONTROL SYSTEMS
RFSOLUTIONS

FIREFLY-TX2

VIPER Remote Control Systems
RFMD

FIREFLY-TX4

RADIO REMOTE CONTROL SYSTEMS
RFSOLUTIONS