RP10-2405SA [RECOM]

10 Watt Single & Dual Output;
RP10-2405SA
型号: RP10-2405SA
厂家: RECOM INTERNATIONAL POWER    RECOM INTERNATIONAL POWER
描述:

10 Watt Single & Dual Output

文件: 总7页 (文件大小:524K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
• 2:1 Wide Input Voltage Range  
• 1.6kVDC Isolation  
• UL Certified  
Features  
DC/DC Converter  
• Efficiency up to 91%  
• Six-Sided Continuous Shield  
• No Minimum Load Required  
Regulated  
Converters  
RP10-A  
10 Watt  
1“x1“  
Single & Dual  
Output  
Description  
The RP10-A series are wide input voltage range 1”x1” power DC/DC converters. Despite their small  
size, the RP10-A converters are fully specified devices with built-in Class B EMC filters, no minimum  
load, 1.6kVDC isolation, under-voltage lockout and low ripple/noise figures. The outputs are fully pro-  
tected against short circuits, overcurrent and overvoltage and can be trimmed over a +/-10% range.  
The RP10-A series will find many uses in applications where board space is at a premium as no exter-  
nal components are required.  
Selection Guide  
Part Number  
Input  
Output  
Voltage Range Voltage  
Output  
Current  
[mA]  
3000  
2000  
830  
670  
416  
3000  
2000  
830  
670  
416  
3000  
2000  
830  
670  
416  
1000  
416  
333  
Input(1) Efficiency(1) Max. Capacitive  
Current  
[mA]  
typ.  
[%]  
Load  
[µF]  
3500  
2500  
430  
350  
125  
3500  
2500  
430  
350  
125  
3500  
2500  
430  
350  
125  
1440  
250  
180  
[VDC]  
9-18  
9-18  
9-18  
9-18  
[VDC]  
3.3  
5
12  
15  
24  
3.3  
5
12  
15  
24  
3.3  
5
12  
15  
24  
5
RP10-123.3SA(2,3)  
RP10-1205SA(2,3)  
RP10-1212SA(2,3)  
RP10-1215SA(2,3)  
RP10-1224SA(2,3)  
RP10-243.3SA(2,3)  
RP10-2405SA(2,3)  
RP10-2412SA(2,3)  
RP10-2415SA(2,3)  
RP10-2424SA(2,3)  
RP10-483.3SA(2,3)  
RP10-4805SA(2,3)  
RP10-4812SA(2,3)  
RP10-4815SA(2,3)  
RP10-4824SA(2,3)  
RP10-1205DA(2,3)  
RP10-1212DA(2,3)  
RP10-1215DA(2,3)  
RP10-2405DA(2,3)  
RP10-2412DA(2,3)  
RP10-2415DA(2,3)  
RP10-4805DA(2,3)  
RP10-4812DA(2,3)  
RP10-4815DA(2,3)  
994  
969  
933  
931  
914  
485  
484  
456  
465  
457  
243  
239  
230  
233  
229  
969  
935  
925  
484  
462  
463  
239  
229  
231  
83  
86  
89  
90  
91  
85  
86  
91  
90  
91  
85  
87  
90  
90  
91  
86  
89  
90  
86  
90  
90  
87  
91  
90  
9-18  
18-36  
18-36  
18-36  
18-36  
18-36  
36-75  
36-75  
36-75  
36-75  
36-75  
9-18  
9-18  
9-18  
12  
15  
5
12  
15  
5
18-36  
18-36  
18-36  
36-75  
36-75  
36-75  
1000  
416  
333  
1000  
416  
333  
1440  
250  
180  
1440  
250  
180  
12  
15  
Notes:  
Note1: at nominal input voltage and full load.  
E196683  
Model Numbering  
UL60950-1 Certified  
RP10-__ __ _A/_ _  
Input Voltage  
Package(3)  
CTRL Logic(2)  
Output Voltage  
Single or Dual  
Ordering Examples  
RP10-2405SA/P = 24V Input, 5V Output, Positive Logic CTRL pin and Trim pin fitted  
RP10-4805DA/XC-HC = 48V Input, 5V Output, without CTRL pin, with fitted Heat-sink  
RP10-2405SA/N = 24V Input, 5V Output, Negative Logic CTRL pin and Trim pin fitted  
Notes:  
Note2: standard part is with suffix “P” for positive logic (1=ON, 0=OFF) and trim pin  
add suffix “N” instead for negative logic (0=ON, 1=OFF) and trim pin  
or add suffix “XC” instead for no CTRL pin  
Note3: add suffix “-HC” for premounted Heat-sink with clamps  
www.recom-power.com  
REV.: 0/2016  
PD-1  
RP10-A  
DC/DC Converter  
Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted  
Series  
BASIC CHARACTERISTICS  
Parameter  
Condition  
Min.  
Typ.  
Max.  
nom. Vin = 12V  
nom. Vin = 24V  
nom. Vin = 48V  
9VDC  
18VDC  
36VDC  
12VDC  
24VDC  
48VDC  
18VDC  
36VDC  
75VDC  
Input Voltage Range  
DC-DC ON  
DC-DC OFF  
9VDC  
18VDC  
36VDC  
Vin = 12V  
Vin = 24V  
Vin = 48V  
8VDC  
16VDC  
33VDC  
DC-DC ON  
DC-DC OFF  
Under Voltage Lockout (UVLO)  
DC-DC ON  
DC-DC OFF  
Input Filter  
Pi-Type  
Input Reflected Ripple Current  
nominal Vin and full load  
30mAp-p  
Vin = 12V, 1s max.  
Vin = 24V, 1s max.  
Vin = 48V, 1s max.  
25VDC  
50VDC  
100VDC  
Input Surge Voltage  
Power up  
Remote ON/OFF  
30ms  
30ms  
Start-up time  
Operating Frequency Range  
Minimum Load  
297kHz  
0%  
330kHz  
363kHz  
of full load  
output voltage trimmed up 10%  
output voltage trimmed up 20%  
11W  
12W  
Optional Power  
measured by 20MHz bandwidth 3.3Vout, 5Vout  
with a 10µF/25V X7R 1206 MLCC 12Vout, 15Vout  
40mVp-p  
60mVp-p  
Ripple and Noise  
measured by 20MHz bandwidth  
24Vout  
60mVp-p  
with a 1µF/50V X7R 1206 MLCC  
DC-DC ON  
Positive Logic  
Open or 3.0 < Vr < 15VDC  
Short or 0 < Vr < 1.2VDC  
DC-DC OFF  
Remote ON/OFF  
DC-DC ON  
Negative Logic  
Short or 0 < Vr < 1.2VDC  
Open or 3.0 < Vr < 15VDC  
DC-DC OFF  
DC-DC OFF  
DC-DC ON  
2.5mA  
1.0mA  
Input current of Remote pin (CTRL)  
-0.5 mA  
RP10-2405SA  
Efficiency vs. Output Current  
Efficiency vs. Input Voltage  
95  
90  
85  
80  
75  
70  
65  
60  
55  
50  
45  
40  
90  
85  
80  
75  
70  
65  
60  
18Vin  
24Vin  
30Vin  
36Vin  
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
18  
20  
22  
24  
26  
28  
30  
32  
34  
36  
Output Current [%]  
Input Voltage [V]  
PD-2  
REV.: 0/2016  
www.recom-power.com  
RP10-A  
DC/DC Converter  
Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted  
Series  
REGULATION  
Parameter  
Condition  
Value  
Output Voltage Accuracy  
1%  
3.3Vout, 12Vout  
Others  
10%  
-10% to +20%  
Voltage adjustability(4)  
Single  
low line to high line  
0% to 100% load  
10% to 90% load  
Single  
Dual  
0.2%  
0.5%  
Line Voltage Regulation  
Single  
Dual  
0.2%  
1.0%  
Load Voltage Regulation  
Single  
Dual  
0.1%  
0.8%  
Cross Regulation  
asymmetrical 25%<>100% load  
25% load step change  
5%  
Transient Response recovery time  
250µs typ.  
Notes:  
Note4: Trimming allows the user to increase or decrease the output voltage set point of the module. This is accomplished by connecting  
an external resistor between the Trim pin and either +Vout pin or -Vout pin.  
External Output Trimming  
Output Voltage Trimming  
Single output Powerline converters offer the feature of trimming the output voltage over a certain range around the nominal value by using  
external trim resistors. No general equation can be given for calculating the trim resistors, but the following trimtables give typical values for  
chosing these trimming resistors. If voltages between the given trim points are required, extrapolate between the two nearest given values to  
work out the resis tor required or use a variable resistor to set the output voltage.  
TRIM UP  
TRIM DOWN  
6
5
4
R
U
R
D
5
RP10-xx3.3SA  
Trim up  
1
2
3
4
5
6
7
8
9
10  
%
Vout =  
RU =  
3.333  
3.366  
191.51  
3.399  
126.99  
3.432  
94.73  
3.465  
75.37  
3.498  
62.47  
3.531  
53.25  
3.564  
46.34  
3.597  
40.96  
3.63  
36.66  
Volts  
KOhms  
385.07  
Trim down  
Vout =  
RD =  
1
2
3
4
5
6
7
8
9
10  
%
3.267  
116.72  
3.234  
54.78  
3.201  
34.13  
3.168  
23.81  
3.135  
17.62  
3.102  
13.49  
3.069  
10.54  
3.036  
8.32  
3.003  
6.60  
2.97  
5.23  
Volts  
KOhms  
RP10-xx05SA  
Trim up  
1
2
3
4
5
6
7
8
9
10  
%
Vout =  
RU =  
5.05  
5.10  
5.15  
83.12  
5.20  
61.82  
5.25  
49.05  
5.30  
40.53  
5.35  
34.45  
5.4  
5.45  
26.34  
5.50  
23.50  
Volts  
KOhms  
253.45  
125.70  
29.89  
Trim up  
Vout =  
RU =  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
%
5.55  
21.18  
5.60  
19.24  
5.65  
17.60  
5.70  
16.20  
5.75  
14.98  
5.80  
13.92  
5.85  
12.98  
5.90  
12.14  
5.95  
11.39  
6.00  
10.73  
Volts  
KOhms  
Trim down  
Vout =  
RD =  
1
2
3
4
5
6
7
8
9
10  
%
4.95  
4.90  
4.85  
78.01  
4.80  
56.71  
4.75  
43.94  
4.70  
35.42  
4.65  
29.34  
4.60  
24.78  
4.55  
21.23  
4.50  
18.39  
Volts  
KOhms  
248.34  
120.59  
continued on next page  
REV.: 0/2016  
www.recom-power.com  
PD-3  
RP10-A  
DC/DC Converter  
Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted  
Series  
RP10-xx12SA  
Trim up  
Vout =  
RU =  
1
2
3
4
5
6
7
8
9
10  
%
12.12  
203.22  
12.24  
99.06  
12.36  
64.33  
12.48  
46.97  
12.60  
36.56  
12.72  
29.61  
12.84  
24.65  
12.96  
20.93  
13.08  
18.04  
13.20  
15.72  
Volts  
KOhms  
Trim down  
Vout =  
RD =  
1
2
3
4
5
6
7
8
9
10  
%
11.88  
776.56  
11.76  
380.72  
11.64  
248.78  
11.52  
182.81  
11.40  
143.22  
11.28  
116.83  
11.16  
97.98  
11.04  
83.85  
10.92  
72.85  
10.8  
64.06  
Volts  
KOhms  
RP10-xx15SA  
Trim up  
1
2
3
4
5
6
7
8
9
10  
%
Vout =  
RU =  
15.15  
15.30  
78.22  
15.45  
50.45  
15.60  
36.56  
15.75  
28.22  
15.90  
22.67  
16.05  
18.70  
16.20  
15.72  
16.35  
13.41  
16.50  
11.56  
Volts  
KOhms  
161.56  
Trim up  
Vout =  
RU =  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
%
16.65  
10.04  
16.80  
8.78  
16.95  
7.71  
17.10  
6.80  
17.25  
6.00  
17.40  
5.31  
17.55  
4.69  
17.70  
4.15  
17.85  
3.66  
18.00  
3.22  
Volts  
KOhms  
Trim down  
Vout =  
RD =  
1
2
3
4
5
6
7
8
9
10  
%
14.85  
818.22  
14.70  
401.56  
14.55  
262.67  
14.40  
193.22  
14.25  
151.56  
14.10  
123.78  
13.95  
103.94  
13.80  
89.06  
13.65  
77.48  
13.50  
68.22  
Volts  
KOhms  
RP10-xx24SA  
Trim up  
1
2
3
4
5
6
7
8
9
10  
%
Vout =  
RU =  
24.24  
24.48  
278.67  
24.72  
181.44  
24.96  
132.83  
25.20  
13.67  
25.44  
84.22  
25.68  
70.33  
25.92  
59.92  
26.16  
51.82  
26.40  
45.33  
Volts  
KOhms  
570.33  
Trim up  
Vout =  
RU =  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
%
26.64  
40.03  
26.88  
35.61  
27.12  
31.87  
27.36  
28.67  
27.60  
25.89  
27.84  
23.46  
28.08  
21.31  
28.32  
19.41  
28.56  
17.70  
28.80  
16.17  
Volts  
KOhms  
Trim down  
Vout =  
RD =  
1
2
3
4
5
6
7
8
9
10  
%
23.76  
4947.67  
23.52  
2439.33  
23.28  
1603.22  
23.04  
1185.17  
22.80  
934.33  
22.56  
767.11  
22.32  
647.67  
22.08  
558.08  
21.84  
488.41  
21.60  
Volts  
432.67 KOhms  
PROTECTION  
Parameter  
Condition  
Value  
Short Circuit Protection (SCP)  
continuous, automatic recovery  
3.3Vout  
5Vout  
3.7 - 5.4V  
6.3 - 7.4V  
Over Voltage Protection (OVP)  
Zener Diode Clamp 12Vout  
13.5 - 19.6V  
18.3 - 22.0V  
29.1 - 32.5V  
15Vout  
24Vout  
Over Load Protection (OLP)  
Isolation Voltage  
Hiccup mode  
150% typ.  
I/P to O/P  
I/P (O/P) to case  
tested with 500VDC  
1.6kVDC/1 minute  
1.0kVDC/1 minute  
1Gmin.  
Isolation Resistance  
Isolation Capacitance  
1500pF max.  
Notes:  
Note5: This power module is not internally fused. An input line fuse must always be used.  
PD-4  
REV.: 0/2016  
www.recom-power.com  
RP10-A  
DC/DC Converter  
Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted  
Series  
ENVIRONMENTAL  
Parameter  
Condition  
Value  
without derating  
with derating  
-40°C to +78°C  
-40°C to +100°C  
Operating Temperature Range  
Maximum Case Temperature  
Temperature Coefficient  
+105°C  
0.02%/°C max.  
Natural convection (20LFM) without Heat-sink  
Natural convection (20LFM) with Heat-sink  
18.2°C/W  
15.8°C/W  
Thermal Impedance  
Operating Humidity  
Thermal Shock  
Vibration  
5% - 95% RH  
MIL-STD-810F  
MIL-STD-810F  
3308 x 103 hours  
MTBF  
MIL-HDBK-217F  
Derating Graph(6)  
RP10-2405SA  
RP10-2405SA-HC  
100  
80  
60  
40  
20  
0
100  
80  
60  
40  
20  
0
-40 -20  
0
20 40  
60 78 80 100  
-40 -20  
0
20 40  
60  
80 100  
Ambient Temperature [°8C1]  
Ambient Temperature [°C]  
Notes:  
Note6: Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-  
number not shown here please contact our technical support service at techsupportAT@recom-power.com  
SAFETY AND CERTIFICATIONS  
Certificate Type (Safety)  
Report / File Number  
Standard  
UL60950-1, 1st Ed.: 2003  
C22.2 No. 60950, 1st Ed.: 2003  
UL General Safety  
E196683  
EMC Compliance  
EMI Standard(7)  
Condition  
with external filter  
Standard / Criterion  
EN55022, Class A or B  
ESD  
Air 8kV and Contact 6kV  
EN61000-4-2, Criteria A  
EN61000-4-3, Criteria A  
EN61000-4-4, Criteria A  
EN61000-4-5, Criteria A  
EN61000-4-6, Criteria A  
EN61000-4-8, Criteria A  
Radiated Immunity  
Fast Transient(8)  
Surge(8)  
Conducted Immunity  
Power frequency magnetic field  
10 V/m  
2kV  
1kV  
3 Vr.m.s  
100A/m continuous, 1000A/m 1 second  
Notes:  
Note7: The standard modules meet EMI Class A without external components and Class B with external components; see filter suggestions  
below. RP10-4805SA meets EMI Class B without external components.  
Note8: An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5. The filter capacitor Recom  
suggests: Nippon chemi-con KY series, 220µF/100V.  
continued on next page  
www.recom-power.com  
REV.: 0/2016  
PD-5  
RP10-A  
DC/DC Converter  
Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted  
Series  
EMI Filtering Class B  
Fuse  
Fuse  
+V  
OUT  
+V  
OUT  
+V  
IN  
+V  
IN  
Input  
Input  
DC  
DC  
C1  
C1  
GND  
DC  
DC  
-V  
OUT  
-V  
OUT  
-V  
IN  
-V  
IN  
MODEL  
C1  
10µF/25V  
1812 MLCC  
RP10-12xxS_DA  
6.8µF/50V  
1812 MLCC  
RP10-24xxS_DA  
RP10-48xxS_DA  
4.7µF/100V  
1812 MLCC  
DIMENSIONS and PHYSICAL CHARACTERISTICS  
Parameter  
Type  
Value  
Case  
Base  
Copper Alloy C2680  
FR4 PCB  
Material  
Potting  
Epoxy (UL94-V0)  
without Heat-sink  
with Heat-sink  
25.4 x 25.4 x 9.9mm  
31.4 x 25.4 x 16.5mm  
Package Dimensions (LxWxH)  
Package Weight  
without Heat-sink  
with Heat-sink  
16.5g  
22.94g  
Dimension Drawing (mm)  
25.4  
25.4  
Pin Connections  
Pin # Single  
Dual  
Ø 1.0  
1
+Vin  
-Vin  
+Vin  
-Vin  
2
3
4
5
6
20.32  
CTRL(2)  
+Vout  
Trim  
CTRL(2)  
+Vout  
Com  
4
-Vout  
-Vout  
1
Bottom View  
5
6
Pin Pitch Tolerance 0.25mm  
Pin dimension tolerance 0.1mm  
XX.X 0.5mm  
2
XX.XX 0.25mm  
3
continued on next page  
REV.: 0/2016  
PD-6  
www.recom-power.com  
RP10-A  
DC/DC Converter  
Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted  
Series  
Dimension Drawing (mm) with Heat-sink  
24.20  
Top View  
Heat-sink  
2.54  
20.32  
25.4  
Ø 1.0  
31.4  
PACKAGING INFORMATION  
Parameter  
Type  
Value  
Tube  
Tray  
257 x 28.5 x 21mm  
230 x 180 x 28mm  
Packaging Dimensions (LxWxH)  
without Heat-sink Tube  
with Heat-sink Tray  
8pcs.  
20pcs.  
Packaging Quantity  
Storage Temperature Range  
Storage Humidity  
-55°C to +125°C  
5% - 95% RH  
Tube Dimension Drawing (mm)  
R1.5  
14.5±±.5  
26.5±±.5  
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written  
consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer  
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.  
www.recom-power.com  
REV.: 0/2016  
PD-7  

相关型号:

RP10-2405SA/N

DC DC CONVERTER 5V 10W
ETC

RP10-2405SA/N-HC

CONV DC/DC 10W 18-36VIN 05VOUT 1
ETC

RP10-2405SA/P

CONV DC/DC 10W 18-36VIN 05VOUT 1
ETC

RP10-2405SA/XC-HC

CONV DC/DC 10W 18-36VIN 05VOUT T
ETC

RP10-2405SAW

10 Watt Single & Dual Output
RECOM

RP10-2405SAW/N

CONV DC/DC 10W 9-36VIN 05VOUT 1"
ETC

RP10-2405SAW/N-HC

DC DC CONVERTER 5V 10W
ETC

RP10-2405SAW/XC

CONV DC/DC 10W 9-36VIN 05VOUT 2"
ETC

RP10-2405SAW/XC-HC

CONV DC/DC 10W 9-36VIN 05VOUT TH
ETC

RP10-2405SE

10 Watt 2inch x 1inch Package Single & Dual Output
RECOM

RP10-2405SE-HC

CONV DC/DC 10W 18-36VIN 05VOUT
ETC

RP10-2405SE/M1

CONV DC/DC 10W 18-36VIN 05VOUT
ETC