RP10-2405SA/N-HC [ETC]
CONV DC/DC 10W 18-36VIN 05VOUT 1;型号: | RP10-2405SA/N-HC |
厂家: | ETC |
描述: | CONV DC/DC 10W 18-36VIN 05VOUT 1 |
文件: | 总8页 (文件大小:570K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
• 2:1 input voltage range
• 1.6kVDC isolation
Features
DC/DC Converter
• UL certified
• Efficiency up to 91%
• Six-sided continuous shield
• No minimum load required
Regulated
Converter
RP10-A
10 Watt
1“ x 1“
Single and Dual
Output
Description
3
The RP10-A series are wide input voltage range 1”x1” power DC/DC converters. Despite their small
size, the RP10-A converters are fully specified devices with built-in Class A EMC filters, no minimum
load, 1.6kVDC isolation, under-voltage lockout and low ripple/noise figures. The outputs are fully
protected against short circuits, overcurrent and overvoltage and can be trimmed over a 10ꢀ range.
The RP10-A series will find many uses in applications where board space is at a premium as no
external components are required.
Selection Guide
Part Number
Input
Output
Voltage Range Voltage
Output
Current
[mA]
3000
2000
830
670
416
3000
2000
830
670
416
3000
2000
830
670
416
1000
416
333
Input (1) Efficiency (1) Max. Capacitive
Current
[mA]
typ.
[%]
Load (2)
[µF]
3500
2500
430
350
125
3500
2500
430
350
125
3500
2500
430
350
125
1440
250
180
[VDC]
9-18
9-18
9-18
9-18
[VDC]
3.3
5
12
15
24
3.3
5
12
15
24
3.3
5
12
15
24
5
RP10-123.3SA (2,3)
RP10-1205SA (2,3)
RP10-1212SA (2,3)
RP10-1215SA (2,3)
RP10-1224SA (2,3)
RP10-243.3SA (2,3)
RP10-2405SA (2,3)
RP10-2412SA (2,3)
RP10-2415SA (2,3)
RP10-2424SA (2,3)
RP10-483.3SA (2,3)
RP10-4805SA (2,3)
RP10-4812SA (2,3)
RP10-4815SA (2,3)
RP10-4824SA (2,3)
RP10-1205DA (2,3)
RP10-1212DA (2,3)
RP10-1215DA (2,3)
RP10-2405DA (2,3)
RP10-2412DA (2,3)
RP10-2415DA (2,3)
RP10-4805DA (2,3)
RP10-4812DA (2,3)
RP10-4815DA (2,3)
994
969
933
931
914
485
484
456
465
457
243
239
230
233
229
969
935
925
484
462
463
239
229
231
83
86
89
90
91
85
86
91
90
91
85
87
90
90
91
86
89
90
86
90
90
87
91
90
9-18
18-36
18-36
18-36
18-36
18-36
36-75
36-75
36-75
36-75
36-75
9-18
RoHS2
+
REACH
compliant
compliant
10 from 10
E196683
UL60950-1 certified
EN55032 compliant
9-18
9-18
12
15
5
12
15
5
18-36
18-36
18-36
36-75
36-75
36-75
1000
416
333
1000
416
333
1440
250
180
1440
250
180
12
15
Notes:
Note1: Maximum values at nominal input voltage and full load
Note2: Max. Cap load is tested at nominal input and full resistive load
Model Numbering
RP10-__ __ _A/_-_
“Package (4)”
nom. Input Voltage
nom. Output Voltage
“CTRL Logic (3)”
Single or Dual
Notes:
Note3: add suffix ”P” for CTRL function with positive logic (1=ON, 0=OFF) and Trim pin
add suffix “N” for CTRL function with negative logic (0=ON, 1=OFF) and Trim pin
or add suffix “XC” for omitted CTRL pin and Trim pin (refer to “Dimension Drawing (mm)”)
Note4: add suffix “-HC” for premounted Heat-sink with clamps
Ordering Examples
RP10-1205SA/P = 12V input, 5V output, single, positive Logic CTRL pin
RP10-4805DA/XC-HC = 48V input, 5V output, dual, without CTRL pin, Heat-sink premounted
www.recom-power.com
REV.: 6/2020
PD-1
RP10-A
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Max.
Internal Input Filter
Pi-Type
nom. Vin = 12VDC
nom. Vin = 24VDC
nom. Vin = 48VDC
9VDC
18VDC
36VDC
12VDC
24VDC
48VDC
18VDC
36VDC
75VDC
25VDC
50VDC
100VDC
9VDC
Input Voltage Range
Input Surge Voltage
nom. Vin = 12VDC
nom. Vin = 24VDC
nom. Vin = 48VDC
DC-DC ON
1s max.
nom. Vin = 12VDC
nom. Vin = 24VDC
DC-DC OFF
8VDC
16VDC
33VDC
DC-DC ON
DC-DC OFF
18VDC
36VDC
Under Voltage Lockout (UVLO)
DC-DC ON
DC-DC OFF
nom. Vin = 48VDC
refer to
3.3Vout, 12Vout
Others
-10%
-10%
+10%
+20%
Output Voltage Trimming
Minimum Load
“OUTPUT VOLTAGE TRIMMING”
0%
Power up
ON/OFF CTRL
30ms
30ms
Start-up Time
DC-DC ON
DC-DC OFF
Open or 3.0VDC < VCTRL< 15VDC
Short or 0VDC < VCTRL< 1.2VDC
Positive Logic
Negative Logic
ON/OFF CTRL (5)
refer to “ON/OFF CTRL”
DC-DC ON
DC-DC OFF
Short or 0VDC < VCTRL< 1.2VDC
Open or 3.0VDC < VCTRL< 15VDC
+1.0mA
drive current
DC-DC OFF
-0.5mA
297kHz
Input Current of CTRL pin
Standby Current
ICTRL
IIn
2.5mA
Internal Operating Frequency
330kHz
363kHz
measured at 20MHz BW,
with a 10µF/25V X7R 1206 MLCC
3.3Vout, 5Vout
12Vout, 15Vout
40mVp-p
60mVp-p
Output Ripple and Noise
measured at 20MHz BW,
24Vout
60mVp-p
30mAp-p
with a 1µF/50V X7R 1206 MLCC
Input Reflected Ripple Current
Notes:
Note5: If suffix “XC” is specified, the control pin will be absent. If fitted, the ON/OFF control function
can be positive or negative logic. The pin voltage is referenced to -Vin
RP10-2405SA
Efficiency vs. Input Voltage full load
Efficiency vs. Output Current
90
85
80
75
70
65
60
95
90
85
80
75
70
65
60
55
50
45
40
18Vin
24Vin
30Vin
36Vin
10
20
30
40
50
60
70
80
90
100
18
20
22
24
26
28
30
32
34
36
Output Current [%]
Input Voltage [VDC]
www.recom-power.com
REV.: 6/2020
PD-2
RP10-A
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
ON/OFF CTRL
IIN
+Vin
+Vout
+Vin
+Vout
DC-DC ON
DC-DC OFF
Open or 3.0VDC < VCTRL < 15VDC
Short or 0VDC < VCTRL < 1.2VDC
Positve Logic
Negativ Logic
ICTRL
CTRL
-Vin
VCTRL
DC-DC ON
DC-DC OFF
Short or 0VDC < VCTRL < 1.2VDC
Open or 3.0VDC < VCTRL < 15VDC
-Vout
-Vin
-Vout
OUTPUT VOLTAGE TRIMMING
Output Voltage Trimming
Single output Powerline converters offer the feature of trimming the output voltage over a certain range around the nominal value by using external
trim resistors. No general equation can be given for calculating the trim resistors, but the following trimtables give typical values for choosing these
trimming resistors. If voltages between the given trim points are required, extrapolate between the two nearest given values to work out the resistor
required or use a variable resistor to set the output voltage. Output can be externally trimmed by using the method shown below.
Trim up
Trim down
-Vout
Trim
R
R
D
U
+Vout
Trim
RP10-xx3.3SA
[%]
[VDC]
[kW]
Trim up
1
2
3
4
5
6
7
8
9
10
Vout =
RU =
3.333
3.366
191.511
3.399
126.990
3.432
94.730
3.465
3.498
3.531
3.564
46.340
3.597
40.963
3.63
385.071
75.374
62.470
53.253
36.662
[%]
[VDC]
[kW]
Trim down
Vout =
RD =
1
2
3
4
5
6
7
8
9
10
3.267
116.719
3.234
54.779
3.201
34.133
3.168
23.810
3.135
17.616
3.102
13.486
3.069
10.537
3.036
8.325
3.003
6.604
2.97
5.228
RP10-xx05SA
Trim up
[%]
[VDC]
[kW]
1
2
3
4
5
6
7
8
9
10
Vout =
5.05
5.10
5.15
5.20
5.25
5.30
5.35
5.4
5.45
5.50
RU =
253.450
125.700
83.117
61.825
49.050
40.533
34.450
29.888
26.339
23.500
[%]
[VDC]
[kW]
Trim up
Vout =
RU =
11
12
13
14
15
16
17
18
19
20
5.55
5.60
5.65
5.70
5.75
5.80
5.85
5.90
5.95
6.00
21.177
19.242
17.604
16.200
14.983
13.919
12.979
12.144
11.397
10.725
[%]
[VDC]
[kW]
Trim down
Vout =
RD =
1
2
3
4
5
6
7
8
9
10
4.95
4.90
4.85
4.80
4.75
4.70
4.65
4.60
4.55
4.50
248.340
120.590
78.007
56.715
43.940
35.423
29.340
24.778
21.229
18.390
RP10-xx12SA
[%]
[VDC]
[kW]
Trim up
1
2
3
4
5
6
7
8
9
10
Vout =
RU =
12.12
12.24
99.057
12.36
64.334
12.48
46.973
12.60
36.557
12.72
29.612
12.84
24.652
12.96
20.932
13.08
18.038
13.20
15.723
203.223
[%]
[VDC]
[kW]
Trim down
Vout =
RD =
1
2
3
4
5
6
7
8
9
10
11.88
776.557
11.76
380.723
11.64
248.779
11.52
182.807
11.40
11.28
116.834
11.16
97.985
11.04
83.848
10.92
72.853
10.8
143.223
64.057
continued on next page
REV.: 6/2020
www.recom-power.com
PD-3
RP10-A
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
RP10-xx15SA
[%]
[VDC]
[kW]
Trim up
Vout =
RU =
1
2
3
4
5
6
7
8
9
10
15.15
161.557
15.30
78.223
15.45
50.446
15.60
36.557
15.75
28.223
15.90
22.668
16.05
18.700
16.20
15.723
16.35
13.409
16.50
11.557
[%]
[VDC]
[kW]
Trim up
Vout =
RU =
11
12
13
14
15
16
17
18
19
20
16.65
10.042
16.80
8.779
16.95
7.711
17.10
6.795
17.25
6.001
17.40
5.307
17.55
4.694
17.70
4.149
17.85
3.662
18.00
3.223
[%]
[VDC]
[kW]
Trim down
Vout =
RD =
1
2
3
4
5
6
7
8
9
10
14.85
818.223
14.70
401.557
14.55
262.668
14.40
193.223
14.25
151.557
14.10
123.779
13.95
103.938
13.80
89.057
13.65
77.483
13.50
68.223
RP10-xx24SA
[%]
[VDC]
[kW]
Trim up
1
2
3
4
5
6
7
8
9
10
Vout =
RU =
24.24
24.48
278.667
24.72
181.444
24.96
132.833
25.20
13.667
25.44
84.222
25.68
70.333
25.92
59.917
26.16
51.815
26.40
45.333
570.333
[%]
[VDC]
[kW]
Trim up
Vout =
RU =
11
12
13
14
15
16
17
18
19
20
26.64
40.030
26.88
35.611
27.12
31.872
27.36
28.667
27.60
25.889
27.84
23.458
28.08
21.314
28.32
19.407
28.56
17.702
28.80
16.167
[%]
[VDC]
[kW]
Trim down
Vout =
RD =
1
2
3
4
5
6
7
8
9
10
23.76
23.52
23.28
23.04
22.80
22.56
767.111
22.32
647.667
22.08
558.083
21.84
488.407
21.60
4947.667 2439.333 1603.222 1185.167 934.333
432.667
REGULATIONS
Parameter
Condition
Value
Output Accuracy
1.0%
low line to high line,
Single
Dual
0.2%
0.5%
Line Regulation
Load Regulation
full load
Single
Dual
0.2%
1.0%
0% to 100% load
Single
Dual
0.1%
0.8%
10% to 90% load
Cross Regulation
asymmetrical 25%<>100% load
25% load step change
5.0%
Transient Response Recovery Time
250µs typ.
www.recom-power.com
REV.: 6/2020
PD-4
RP10-A
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
PROTECTIONS
Parameter
Condition
Value
Short Circuit Protection (SCP)
continuous, automatic recovery
3.3Vout
5Vout
3.7 - 5.4VDC
6.3 - 7.4VDC
Over Voltage Protection (OVP)
zener diode clamp
12Vout
15Vout
24Vout
13.5 - 19.6VDC
18.3 - 22.0VDC
29.1 - 32.5VDC
Over Load Protection (OLP)
Isolation Voltage(6)
% of Iout rated
150% typ., Hiccup mode
I/P to O/P
I/P to O/P to case
1.6kVDC/ 1 minute
1.0kVDC/ 1 minute
1GW min.
Isolation Resistance
Isolation Capacitance
Viso= 500VDC
1500pF max.
Notes:
Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note7: This power module is not internally fused. An input line fuse must always be used
Recom suggests: 12Vin= T2A; 24Vin= T1A; 48Vin= T0.5A slow blow types
ENVIRONMENTAL
Parameter
Condition
Value
-40°C to +78°C
-40°C to +100°C
without derating
with derating
Operating Temperature Range
Maximum Case Temperature
Temperature Coefficient
+105°C
0.02%/ꢀ max.
@ natural convection
0.1m/s, vertical direction
without heat-sink
with heat-sink
18.2ꢀ/W
15.8ꢀ/W
Thermal Impedance
Operating Humidity
Thermal Shock
Vibration
non-condensing
5% - 95% RH
according to MIL-STD-810F
according to MIL-STD-810F
3308 x 103 hours
MTBF
according to MIL-HDBꢀ-217F, G.B.
+25°C
Derating Graph (8)
RP10-2405SA
RP10-2405SA-HC
100
80
60
40
20
0
100
80
60
40
20
0
-40 -20
0
20 40
60 78 80 100
-40 -20
0
20 40
60
80 100
Ambient Temperature [°8C1]
Ambient Temperature [°C]
Notes:
Note8: Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-number
not shown here please contact RECOM Techsupport for detailed information
www.recom-power.com
REV.: 6/2020
PD-5
RP10-A
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Condition
E196683
Standard
UL60950-1, 1st Edition
CAN/CSA-C22.2 No. 60950-1, 1st Edition
Information Technology Equipment, General Requirements for Safety
EAC
RU-AT.49.09571
TP TC 004/2011
RoHS2+
RoHS-2011/65/EU + AM-2015/863
EMC Compliance
Condition
Standard / Criterion
Electromagnetic compatibility of multimedia equipment - Emission
requirements
without external filter
refer to “EMC Filtering Suggestions”
EN55032, Class A
EN55032, Class B
ESD Electrostatic discharge immunity test
Radiated, radio-frequency, electromagnetic field immunity test
Fast Transient and Burst Immunity (9)
Surge Immunity (9)
Air 8kV and Contact 6kV
EN61000-4-2, Criteria A
EN61000-4-3, Criteria A
EN61000-4-4, Criteria A
EN61000-4-5, Criteria A
EN61000-4-6, Criteria A
EN61000-4-8, Criteria A
10V/m
2kV
1kV
3Vr.m.s
Immunity to conducted disturbances, induced by radio-frequency fields
Power Magnetic Field Immunity
100A/m continuous; 1000A/m 1s
Notes:
Note9: An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5
Recom suggests Nippon chemi-con ꢀY series 220µF/100V
EMC Filtering Suggestions according to EN55032
Single
Dual
F1
F1
+Vin
+Vout
+Vin
-Vin
+Vout
Com
-Vout
+Vin
+Vout
+Vin
-Vin
+Vout
C1
C1
Com
-Vout
-Vin
-Vout
-Vin
-Vout
Component List Class B
MODEL
C1
RP10-12xxSA, RP10-12xxDA
RP10-24xxSA, RP10-24xxDA
RP10-48xxSA, RP10-48xxDA
10µF/25V, 1812 MLCC
6.8µF/50V, 1812 MLCC
4.7µF/100V, 1812 MLCC
DIMENSIONS AND PHYSICAL CHARACTERISTICS
Parameter
Type
case
base
Value
copper alloy C2680
FR4 PCB
Material
potting
epoxy (UL94 V-0)
25.4 x 25.4 x 9.9mm
31.4 x 25.4 x 16.5mm
without Heat-sink
with Heat-sink
Dimensions (LxWxH)
Weight
without Heat-sink
with Heat-sink
16.5g
23g
continued on next page
REV.: 6/2020
www.recom-power.com
PD-6
RP10-A
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
Dimension Drawing (mm)
Pinning Information
25.4
25.4
Pin # Single
Dual
+Vin
-Vin
“/XC“
+Vin
-Vin
1
2
3
4
5
6
+Vin
-Vin
CTRL (3) CTRL (3) no Pin (3)
+Vout
Trim
+Vout
Com
+Vout
Trim
2.54
0.1
8 x 2.54= 20.32
Ø 1.0
-Vout
-Vout
-Vout
Recommended Footprint Details
2.54
Pin Pitch Tolerance 0.25mm
Tolerance: xx.x= ±±.ꢀ55
xx.xx= ±±.ꢁꢀ55
3
6
5
4
4
5
6
2
1
1 Bottom View
Top View
2
3
Dimension Drawing with Heat-sink (mm)
25.4
Top View
Heat-sink
Pinning Information
31.4
24.2
Pin # Single
Dual
“/XC“
+Vin
-Vin
1
2
3
4
5
6
+Vin
+Vin
-Vin
-Vin
CTRL (3) CTRL (3) no Pin (3)
+Vout
Trim
+Vout
Com
+Vout
Trim
0.1
2.54
Ø 1.0
-Vout
-Vout
-Vout
8 x 2.54= 20.32
Recommended Footprint Details
Pin Pitch Tolerance 0.25mm
Tolerance: xx.x= ±±.ꢀ55
xx.xx= ±±.ꢁꢀ55
2.54
3
6
5
4
4
2
1
1 Bottom View
5
Top View
2
3
6
www.recom-power.com
REV.: 6/2020
PD-7
RP10-A
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
PACKAGING INFORMATION
Parameter
Type
Value
tube
tray
without heat-sink
with heat-sink
257.0 x 28.5 x 21.0mm
230.0 x 180.0 x 28.0mm
Packaging Dimension (LxWxH)
tube
tray
without heat-sink
with heat-sink
8pcs
20pcs
Packaging Quantity
Storage Temperature Range
Storage Humidity
-55°C to +125°C
5% - 95% RH
non-condensing
The product information and specifications may be subꢀect to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOMꢁs explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 6/2020
PD-8
相关型号: