PS-DA0105-07 [POWER-SYSTEMS]

DC-AC INVERTER UNIT 3.5 W SINGLE OUTPUTS; DC -AC逆变单元3.5 W单产出
PS-DA0105-07
型号: PS-DA0105-07
厂家: POWER SYSTEMS GMBH+CO.KG    POWER SYSTEMS GMBH+CO.KG
描述:

DC-AC INVERTER UNIT 3.5 W SINGLE OUTPUTS
DC -AC逆变单元3.5 W单产出

输出元件
文件: 总4页 (文件大小:275K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
DC-AC INVERTER UNIT  
PS-DA0105-07(S) (3.5 W SINGLE OUTPUTS)  
DESCRIPTION :  
(PRELIMINARY INFORMATION)  
This low profile DC to AC Inverter is developed for single lamps.  
Optimized for ChiMei Display N121X5-L02  
APPLICABLE LCD:  
6.4 to 15 inches single lamp type  
Lamp Voltage 560 Vrms  
Lamp Current 6.2 mArms  
Lamp Start Up Voltage 1.300 Vrms (Vin : 12.0 Vdc)  
FEATURES :  
Remote ON/OFF  
Open Lamp Detection  
RoHS compliant (S)  
TEMPERATURE & HUMIDITY :  
Operating Temperature Range  
Storage Temperature Range  
Humidity  
0°C ~ +50°C  
-20°C ~ +85°C  
95 %RH max  
DIMENSIONS :  
L x W x H  
95 x 16 x 6,5mm  
Unit : mm  
Weight :7,6 (g) typ.  
Note: Please use plastic screw in case of a non-insulating mounting base!  
Components  
No.  
1
Part Description  
PCB  
Qty.  
Material  
UL94V-0 (FR-4 or CEM-3)  
53261-0590  
Note  
1
1
1
t=1mm  
2
Connector CN1  
Connector CN2  
Molex or equal  
JST or equal  
3
SM02B-BHSS-1-TB  
Output side CN2  
Input side CN1:  
Pin No.  
CN 2-1  
CN 2-2  
Symbols  
Vhigh  
Ratings  
560 Vrms (6,2 mArms)  
(GND)  
Pin No. Symbols  
Ratings  
Vin  
GND  
Vbr  
9.0 ~ 15.0 Vdc  
CN 1-1  
CN 1-2  
CN 1-3  
CN 1-4  
CN 1-5  
Vlow  
0 ~ 5 Vdc  
GND  
Vrmt  
0 ~ 0.4 = OFF / 2.5 ~ Vin = ON  
Power Systems – The Power Solution  
Web:  
www.Power-Systems.de  
Info@Power-Systems.de  
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany  
Email:  
Tel. :  
Fax:  
+ 49 / 70 62 / 67 59 - 6  
+ 49 / 70 62 / 67 59 - 800  
All specifications are subject to change without notice.  
Page (1)  
Version 1.0.1, 22th March 2007  
DC-AC INVERTER UNIT  
PS-DA0105-07(S) (3.5 W SINGLE OUTPUTS)  
ELECTRICAL CHARACTERISTICS :  
(PRELIMINARY INFORMATION)  
Conditions  
Specification  
Parameters  
Symbols  
Unit  
Note  
Vin (V) Vbr(V) Tu (°C)  
Min.  
Typ.  
Max.  
Duty 100%  
Duty M in  
Iout  
Iout  
Iin  
12.0±1.2  
12.0±0.6  
12.0±1.2  
12.0±1.2  
12.0  
5.0  
0.0  
5.0  
5.0  
5.0  
5.0  
0 ~ +50  
0 ~ +50  
0 ~ +50  
0 ~ +50  
5.3  
-
6.2  
23  
6.7  
-
mArms  
%
Output Current  
Output Current  
Input Current  
-
0.33  
60  
0.42  
70  
Adc  
F
50  
kHz  
Vrms  
sec  
Frequency  
Vopen  
Tsd  
0 ~ +50 1.100  
0 ~ +50  
1.300  
1.0  
1.500  
-
Open Circuit Voltage  
No load Shutdown  
without load  
12.0±1.2  
-
Note 1 :  
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked  
on mechanical drawing and any conductors.  
TEST CIRCUIT :  
F
1000:1  
PROBE  
F
V
Vopen  
RL1  
SW1  
a
Operation of unit  
Operation  
Iin  
~
A
Vin  
CN1-1  
CN1-2  
CN1-3  
SW3  
12.0 V  
V
CN2-1  
CN2-2  
CL1  
Non operation  
b
A
T1  
~
Iout1  
SW4  
Vbr  
0 ~ 5 Vdc  
CN1-4  
CN1-5  
a
Vrmt  
0.4 / 5 Vdc  
b SW1  
V
Power Systems – The Power Solution  
Web:  
www.Power-Systems.de  
Info@Power-Systems.de  
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany  
Email:  
Tel. :  
Fax:  
+ 49 / 70 62 / 67 59 - 6  
+ 49 / 70 62 / 67 59 - 800  
All specifications are subject to change without notice.  
Page (2)  
Version 1.0.1, 22th March 2007  
DC-AC INVERTER UNIT  
BACKLIGHT INVERTER INSTALLATION INSTRUCTION  
Precautionary Notes Regarding the Use of This Inverter  
When using this product, give due consideration to the precautionary notes described below  
and ensure a safe design. Inappropriate use may result in electric shock, injury or fire.  
WARNING  
• This product is subject to high voltage. Do not touch it while the power is on. Failing to do so may result in electric shock.  
CAUTION  
• This product is designed for the lighting of a Cold Cathode Fluorescent Lamp. Do not use it with any other load.  
• Store this product under the conditions defined in the specification document.  
• Do not store this product in an environment where dust, dirt or corrosive gas (salt, acid, base, etc.) is present.  
• This product is subject to high voltage. If there is a possibility that the user may touch the product, provide a proper  
indication in order to draw the user’s attention.  
• This product is designed for use with general electronic equipment. If it is to be used with medical equipment that directly  
affects human life or for the control of transportation equipment to which passengers entrust their lives, provide thorough fail-  
safe measures.  
• Avoid using this product under high temperatures or high humidity or in an environment in which dust, dirt or any corrosive  
gas (salt, acid, base, etc.) is present. Also, be careful not to allow the formation of dew condensation. It may result in  
damage or electric shock.  
• If the product does not have a built-in protective circuit (circuit breaker, fuse, etc.), it is recommended that a fuse be used at  
the input stage to prevent the generation of smoke or fire in the event of a malfunction. Even when the product has a built-in  
protective circuit (circuit breaker, fuse, etc.), the circuit may not function properly due to inappropriate operating conditions or  
power-supply capacity. It is recommended that an appropriate protective circuit (circuit breaker, fuse, etc.) be provided  
separately from the built-in circuit.  
• Use the product only within the specified input voltage, output power, output voltage and operating temperature ranges.  
Exceeding these values may result in damage, etc. Abnormal voltage may result in damage, etc.  
• Provide a measure for the preventation of surge voltage due to lighting, etc. Abnormal voltage may result in damage, etc.  
• To prevent problems arising form short-circuiting of the high-voltage section, provide appropriate measures to prevent the  
entry of foreign substances following installation.  
• This product is not designed to provide resistance to radiation.  
HANDLING PRECAUTIONS  
• This product uses thin wires. Observe the following precautions and handle it with care so as not to cause wire breakage.  
Broken wire may result in damage, etc.  
Do not stack multiple products on top of one another,  
Do not allow the product to come in contact with tools, etc.  
• Do not apply excessive stress during installation. It may cause chipping and cracking, resulting in damage, etc  
• Provide a clearance of 2 mm or more between the high-voltage section of this product and the frame body on which the  
product is installed and also the conductor section (pattern, pad, etc.)  
Power Systems – The Power Solution  
Web:  
www.Power-Systems.de  
Info@Power-Systems.de  
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany  
Email:  
Tel. :  
Fax:  
+ 49 / 70 62 / 67 59 - 6  
+ 49 / 70 62 / 67 59 - 800  
All specifications are subject to change without notice.  
Page (1)  
Version 2.0, 15th August 2007  
DC-AC INVERTER UNIT  
Thank you very much for usually patronizing Power Systems and TDK’s DC/AC inverter. Following the expansion of it’s use, there  
are unexpected troubles that are caused by mis-use or mis-handling because the DC/AC inverter generates a high voltage of  
900Vrms or more. Hereafter, the cases of the major troubles are described. Please also refer to “Notes of used” of the attached  
paper.  
Ex.1 Multilayered PWB  
Inverter was mounted the nearest to the main board because there is no surface pattern. However, dielectric breakdown  
happened because there was a low-voltage pattern in internal layer, and they were damaged by arc fire.  
Ex.2 Foreign body  
Short of high voltage area by insect (cockroach etc.) having invaded installed set in food processing plant and counter, etc. Short  
by adhesion of metal powder when using it by set such as NC machine tool.  
Ex.3 Mechanical stress  
Parts will be cracked or the wire of transformer will be broke, etc. When the mechanical stress was given at the installation on the  
set.  
Ex.4 Storage, handling  
When you store it, if the product is piled up or grabed with other inverters together at once, etc. these will be the cause of the  
break of transformer’s wire and etc.  
CABLES CONNECTION  
1.) Don‘t extand cables.  
1.1.) Don‘t cut through nor solder them, unless you have consulted the manufacture.  
2.) Don‘t exchange cables.  
2.1.) Polarity is very important otherwise -will be able to a short circuit.  
-there might be a short circuit.(Please refer to fig.1)  
Fig. 1  
OK  
NG  
Power Systems – The Power Solution  
Web:  
www.Power-Systems.de  
Info@Power-Systems.de  
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany  
Email:  
Tel. :  
Fax:  
+ 49 / 70 62 / 67 59 - 6  
+ 49 / 70 62 / 67 59 - 800  
All specifications are subject to change without notice.  
Page (2)  
Version 2.0, 15th August 2007  

相关型号:

PS-DA0105-07S

DC-AC INVERTER UNIT 3.5 W SINGLE OUTPUTS
POWER-SYSTEMS

PS-DA0109-01

DC-AC INVERTER UNIT 4 W SINGLE OUTPUTS
POWER-SYSTEMS

PS-DA0109-01S

DC-AC INVERTER UNIT 4 W SINGLE OUTPUTS
POWER-SYSTEMS

PS-DA0125-01

DC-AC INVERTER UNIT 4.5 W SINGLE OUTPUT
POWER-SYSTEMS

PS-DA0125-01S

DC-AC INVERTER UNIT 4.5 W SINGLE OUTPUT
POWER-SYSTEMS

PS-DA0125-02

DC-AC INVERTER UNIT 4.5 W DUAL OUTPUTS
POWER-SYSTEMS

PS-DA0125-02S

DC-AC INVERTER UNIT 4.5 W DUAL OUTPUTS
POWER-SYSTEMS

PS-DA0125-03

DC-AC INVERTER UNIT 4.5 W DUAL OUTPUTS
POWER-SYSTEMS

PS-DA0125-03S

DC-AC INVERTER UNIT 4.5 W DUAL OUTPUTS
POWER-SYSTEMS

PS-DA0125-04

DC-AC INVERTER UNIT 4.5 W DUAL OUTPUTS
POWER-SYSTEMS

PS-DA0125-04S

DC-AC INVERTER UNIT 4.5 W DUAL OUTPUTS
POWER-SYSTEMS

PS-DA0125-05

DC-AC INVERTER UNIT 4.5 W DUAL OUTPUTS
POWER-SYSTEMS