PS-DA0125-02S [POWER-SYSTEMS]

DC-AC INVERTER UNIT 4.5 W DUAL OUTPUTS; DC -AC逆变单元为4.5 W双路输出
PS-DA0125-02S
型号: PS-DA0125-02S
厂家: POWER SYSTEMS GMBH+CO.KG    POWER SYSTEMS GMBH+CO.KG
描述:

DC-AC INVERTER UNIT 4.5 W DUAL OUTPUTS
DC -AC逆变单元为4.5 W双路输出

输出元件
文件: 总5页 (文件大小:201K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
DC-AC INVERTER UNIT  
PS-DA0125-02(S) (4.5 W DUAL OUTPUTS)  
DESCRIPTION :  
(PRELIMINARY INFORMATION)  
This low profile DC to AC Inverter is developed for single lamps.  
APPLICABLE LCD:  
3.8 to 15 inches single lamp type  
Lamp Voltage 900 Vrms  
Lamp Current 5 mArms  
Lamp Start Up Voltage 900 Vrms (Vin : 5 Vdc)  
FEATURES :  
RoHS compliant (S)  
4 different output conditions  
TEMPERATURE & HUMIDITY :  
Operating Temperature Range  
Storage Temperature Range  
Humidity  
-10°C ~ +60°C  
-20°C ~ +85°C  
95 %RH max  
DIMENSIONS :  
L x B x H  
44 x 21 x 15 mm  
21Max  
5Min 13Max  
(1.6)  
Bottom view  
Side view  
15.24±0.2  
Jumper (*1)  
1
2
3
4
Unit : mm  
5
Weight :15 (g) typ.  
1.0  
R1.15±0.2  
5-φ0.8±0.1 or 5- 0.64±0.07  
*1 Remove for Isolated  
Ground  
Note: Please use plastic screw in case of a non-insulating mounting base!  
Components  
No.  
1
Part Description  
Qty.  
Material  
Note  
t=1.6mm  
Input  
PCB  
1
2
3
UL94V-0 (FR-4 or CEM-3)  
Pin Terminal  
2
Pin 1; 2  
Pin 3 ~ 5  
3
Pin Terminal  
Output  
Input side  
Pin No. Symbols  
Ratings  
Vin  
4.75 ~ 5.25 Vdc  
-
1
2
GND  
Power Systems – The Power Solution  
Web:  
www.Power-Systems.de  
Info@Power-Systems.de  
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany  
Email:  
Tel. :  
Fax:  
+ 49 / 70 62 / 67 59 - 6  
+ 49 / 70 62 / 67 59 - 800  
All specifications are subject to change without notice.  
Page (1)  
Version 1.4.2, 22th March 2007  
DC-AC INVERTER UNIT  
PS-DA0125-02(S) (4.5 W DUAL OUTPUTS)  
ELECTRICAL CHARACTERISTICS :  
(PRELIMINARY INFORMATION)  
Conditions  
Specification  
Parameters  
Symbols  
Unit  
Connenction  
Vin (V)  
Tu (°C)  
Min.  
Typ.  
Max.  
Iout  
Iout  
Iin  
5±0.05  
23±5  
9.0  
8.0  
-
10.0  
10.0  
0.8  
11.0  
12.0  
1.2  
35  
mArms  
mArms  
Adc  
Output Current  
5±0.25 -10 ~ +60  
5±0.25 -10 ~ +60  
5±0.25 -10 ~ +60  
5±0.25 -10 ~ +60  
1
Input Current  
F
25  
800  
30  
kHz  
Frequency  
Vopen  
900  
-
Vrms  
Open Circuit Voltage  
Iout  
Iout  
Iin  
5±0.05  
23±5  
5.2  
4.6  
-
30  
800  
6.0  
6.0  
0.51  
35  
6.6  
7.2  
0.77  
40  
mArms  
mArms  
Adc  
kHz  
Vrms  
Output Current  
5±0.25 -10 ~ +60  
5±0.25 -10 ~ +60  
5±0.25 -10 ~ +60  
5±0.25 -10 ~ +60  
2
3
Input Current  
Frequency  
Open Circuit Voltage  
F
Vopen  
900  
-
Iout  
Iout  
Iin  
5±0.05  
23±5  
4.5  
4.0  
-
25  
800  
5.0  
5.0  
0.45  
30  
5.6  
6.1  
0.68  
35  
mArms  
mArms  
Adc  
kHz  
Vrms  
Output Current  
5±0.25 -10 ~ +60  
5±0.25 -10 ~ +60  
5±0.25 -10 ~ +60  
5±0.25 -10 ~ +60  
Input Current  
Frequency  
Open Circuit Voltage  
F
Vopen  
900  
-
Iout  
Iout  
Iin  
5±0.05  
23±5  
4.5  
4.0  
-
25  
800  
5.0  
5.0  
0.8  
30  
5.5  
6.0  
1.2  
35  
-
mArms  
mArms  
Adc  
kHz  
Vrms  
Output Current  
5±0.25 -10 ~ +60  
5±0.25 -10 ~ +60  
5±0.25 -10 ~ +60  
5±0.25 -10 ~ +60  
4
Input Current  
Frequency  
Open Circuit Voltage  
F
Vopen  
900  
Note 1 :  
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked  
on mechanical drawing and any conductors.  
Power Systems – The Power Solution  
Web:  
www.Power-Systems.de  
Info@Power-Systems.de  
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany  
Email:  
Tel. :  
Fax:  
+ 49 / 70 62 / 67 59 - 6  
+ 49 / 70 62 / 67 59 - 800  
All specifications are subject to change without notice.  
Page (2)  
Version 1.4.2, 22th March 2007  
DC-AC INVERTER UNIT  
PS-DA0125-02(S) (4.5 W DUAL OUTPUTS)  
TEST CIRCUIT :  
(PRELIMINARY INFORMATION)  
F
F
1000:1  
PROBE  
1000:1  
PROBE  
F
F
V
V
Vopen  
Vopen  
Iin  
~
Iin  
~
A
Vin  
Pin 1  
Pin 2  
Vin  
A
Pin 1  
Pin 2  
4.75 ~ 5.25 Vdc  
4.75 ~ 5.25 Vdc  
N.C.  
Pin 4  
Pin 3  
V
Pin 4  
Pin 3  
V
T1  
T1  
RL1  
RL1  
CL1  
CL1  
A
A
~
~
Iout1  
Iout1  
Pin 5  
Pin 5  
Output side Connection 1  
Output side Connection 2  
Pin No.  
Symbols  
Vhigh  
Ratings  
Pin No.  
Symbols  
Vhigh  
N.C.  
Ratings  
450 Vrms (10 mArms)  
(GND)  
3
4
5
750 Vrms (6 mArms)  
(GND)  
3
4
5
Vhigh  
Vlow  
Vlow  
F
F
1000:1  
PROBE  
Vopen  
1000:1  
PROBE  
F
F
V
~
V
Vopen  
Iin  
Iin  
~
Vin  
A
A
Pin 1  
Pin 1  
Vin  
4.75 ~ 5.25 Vdc  
4.75 ~ 5.25 Vdc  
V
V
Pin 3  
Pin 4  
Pin 3  
Pin 2  
Pin 2  
T1  
T1  
RL2  
RL1  
RL1  
Pin 4  
CL2  
Iout1  
CL1  
CL1  
A
~
A
A
~
~
Iout2  
Iout1  
Pin 5  
Pin 5  
Output side Connection 3  
Output side Connection 4  
Pin No.  
Symbols  
Vhigh  
N.C.  
Ratings  
Pin No.  
Symbols  
Vhigh  
Ratings  
900 Vrms (5 mArms)  
(GND)  
3
4
5
450 Vrms (5 mArms)  
450 Vrms (5 mArms)  
(GND)  
3
4
5
Vhigh  
Vlow  
Vlow  
Power Systems – The Power Solution  
Web:  
www.Power-Systems.de  
Info@Power-Systems.de  
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany  
Email:  
Tel. :  
Fax:  
+ 49 / 70 62 / 67 59 - 6  
+ 49 / 70 62 / 67 59 - 800  
All specifications are subject to change without notice.  
Page (3)  
Version 1.4.2, 22th March 2007  
DC-AC INVERTER UNIT  
BACKLIGHT INVERTER INSTALLATION INSTRUCTION  
Precautionary Notes Regarding the Use of This Inverter  
When using this product, give due consideration to the precautionary notes described below  
and ensure a safe design. Inappropriate use may result in electric shock, injury or fire.  
WARNING  
• This product is subject to high voltage. Do not touch it while the power is on. Failing to do so may result in electric shock.  
CAUTION  
• This product is designed for the lighting of a Cold Cathode Fluorescent Lamp. Do not use it with any other load.  
• Store this product under the conditions defined in the specification document.  
• Do not store this product in an environment where dust, dirt or corrosive gas (salt, acid, base, etc.) is present.  
• This product is subject to high voltage. If there is a possibility that the user may touch the product, provide a proper  
indication in order to draw the user’s attention.  
• This product is designed for use with general electronic equipment. If it is to be used with medical equipment that directly  
affects human life or for the control of transportation equipment to which passengers entrust their lives, provide thorough fail-  
safe measures.  
• Avoid using this product under high temperatures or high humidity or in an environment in which dust, dirt or any corrosive  
gas (salt, acid, base, etc.) is present. Also, be careful not to allow the formation of dew condensation. It may result in  
damage or electric shock.  
• If the product does not have a built-in protective circuit (circuit breaker, fuse, etc.), it is recommended that a fuse be used at  
the input stage to prevent the generation of smoke or fire in the event of a malfunction. Even when the product has a built-in  
protective circuit (circuit breaker, fuse, etc.), the circuit may not function properly due to inappropriate operating conditions or  
power-supply capacity. It is recommended that an appropriate protective circuit (circuit breaker, fuse, etc.) be provided  
separately from the built-in circuit.  
• Use the product only within the specified input voltage, output power, output voltage and operating temperature ranges.  
Exceeding these values may result in damage, etc. Abnormal voltage may result in damage, etc.  
• Provide a measure for the preventation of surge voltage due to lighting, etc. Abnormal voltage may result in damage, etc.  
• To prevent problems arising form short-circuiting of the high-voltage section, provide appropriate measures to prevent the  
entry of foreign substances following installation.  
• This product is not designed to provide resistance to radiation.  
HANDLING PRECAUTIONS  
• This product uses thin wires. Observe the following precautions and handle it with care so as not to cause wire breakage.  
Broken wire may result in damage, etc.  
Do not stack multiple products on top of one another,  
Do not allow the product to come in contact with tools, etc.  
• Do not apply excessive stress during installation. It may cause chipping and cracking, resulting in damage, etc  
• Provide a clearance of 2 mm or more between the high-voltage section of this product and the frame body on which the  
product is installed and also the conductor section (pattern, pad, etc.)  
Power Systems – The Power Solution  
Web:  
www.Power-Systems.de  
Info@Power-Systems.de  
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany  
Email:  
Tel. :  
Fax:  
+ 49 / 70 62 / 67 59 - 6  
+ 49 / 70 62 / 67 59 - 800  
All specifications are subject to change without notice.  
Page (1)  
Version 2.0, 15th August 2007  
DC-AC INVERTER UNIT  
Thank you very much for usually patronizing Power Systems and TDK’s DC/AC inverter. Following the expansion of it’s use, there  
are unexpected troubles that are caused by mis-use or mis-handling because the DC/AC inverter generates a high voltage of  
900Vrms or more. Hereafter, the cases of the major troubles are described. Please also refer to “Notes of used” of the attached  
paper.  
Ex.1 Multilayered PWB  
Inverter was mounted the nearest to the main board because there is no surface pattern. However, dielectric breakdown  
happened because there was a low-voltage pattern in internal layer, and they were damaged by arc fire.  
Ex.2 Foreign body  
Short of high voltage area by insect (cockroach etc.) having invaded installed set in food processing plant and counter, etc. Short  
by adhesion of metal powder when using it by set such as NC machine tool.  
Ex.3 Mechanical stress  
Parts will be cracked or the wire of transformer will be broke, etc. When the mechanical stress was given at the installation on the  
set.  
Ex.4 Storage, handling  
When you store it, if the product is piled up or grabed with other inverters together at once, etc. these will be the cause of the  
break of transformer’s wire and etc.  
CABLES CONNECTION  
1.) Don‘t extand cables.  
1.1.) Don‘t cut through nor solder them, unless you have consulted the manufacture.  
2.) Don‘t exchange cables.  
2.1.) Polarity is very important otherwise -will be able to a short circuit.  
-there might be a short circuit.(Please refer to fig.1)  
Fig. 1  
OK  
NG  
Power Systems – The Power Solution  
Web:  
www.Power-Systems.de  
Info@Power-Systems.de  
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany  
Email:  
Tel. :  
Fax:  
+ 49 / 70 62 / 67 59 - 6  
+ 49 / 70 62 / 67 59 - 800  
All specifications are subject to change without notice.  
Page (2)  
Version 2.0, 15th August 2007  

相关型号:

PS-DA0125-03

DC-AC INVERTER UNIT 4.5 W DUAL OUTPUTS
POWER-SYSTEMS

PS-DA0125-03S

DC-AC INVERTER UNIT 4.5 W DUAL OUTPUTS
POWER-SYSTEMS

PS-DA0125-04

DC-AC INVERTER UNIT 4.5 W DUAL OUTPUTS
POWER-SYSTEMS

PS-DA0125-04S

DC-AC INVERTER UNIT 4.5 W DUAL OUTPUTS
POWER-SYSTEMS

PS-DA0125-05

DC-AC INVERTER UNIT 4.5 W DUAL OUTPUTS
POWER-SYSTEMS

PS-DA0125-05S

DC-AC INVERTER UNIT 4.5 W DUAL OUTPUTS
POWER-SYSTEMS

PS-DA0129-01

DC-AC INVERTER UNIT 5 W SINGLE OUTPUT
POWER-SYSTEMS

PS-DA0129-01S

DC-AC INVERTER UNIT 5 W SINGLE OUTPUT
POWER-SYSTEMS

PS-DA0129-02

DC-AC INVERTER UNIT 5 W SINGLE OUTPUT
POWER-SYSTEMS

PS-DA0129-02S

DC-AC INVERTER UNIT 5 W SINGLE OUTPUT
POWER-SYSTEMS

PS-DA0129-03-E

DC-AC INVERTER UNIT 5 W SINGLE OUTPUT
POWER-SYSTEMS

PS-DA0129-03-ES

DC-AC INVERTER UNIT 5 W SINGLE OUTPUT
POWER-SYSTEMS