2966757 [PHOENIX]

Power/Signal Relay, Momentary, 0.004A (Coil), 220VDC (Coil), 0.1A (Contact), 48VDC (Contact), AC/DC Input, DC Output, DIN-Rail Mount, ROHS COMPLIANT;
2966757
型号: 2966757
厂家: PHOENIX CONTACT    PHOENIX CONTACT
描述:

Power/Signal Relay, Momentary, 0.004A (Coil), 220VDC (Coil), 0.1A (Contact), 48VDC (Contact), AC/DC Input, DC Output, DIN-Rail Mount, ROHS COMPLIANT

继电器
文件: 总4页 (文件大小:243K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
PLC-OS…  
PLC INTERFACE With Solid-State Relay,  
Universal Version  
INTERFACE  
Data Sheet  
103148_en_02  
© PHOENIX CONTACT - 03/2008  
1.2  
Plug-In Bridges Save Wiring  
1
Description  
The PLC INTERFACE module achieves maximum  
efficiency with the user-friendly FBST plug-in bridge system.  
The PLC-OS… makes effective use of the bridging options  
for the A1/A2 connection on the control side and for the  
power supply at connection 13 on the load side. Especially  
effective here are the 500 mm long color-insulated  
continuous plug-in bridges that can easily be cut to the  
required length and quickly inserted in the bridge shafts.  
They eliminate the need for complicated and time-  
consuming loop bridges.  
PLC-OS… relay modules, which can be used universally,  
comprise 6.2 mm basic terminal blocks and plug-in  
miniature solid-state relays with screw or spring-cage  
connection.  
1.1  
Input Voltages From 24 V to 230 V  
The PLC-OS… is available on the control side in all common  
industrial voltages from 24 V to 230 V. A further advantage  
is the ready-integrated input circuit. It consists of a status  
indicator and polarity reversal protection function, and  
ensures that the operating state is displayed clearly, also  
preventing destruction of the optical electronics should the  
polarity be accidentally reversed.  
1.3  
Additional Advantages  
Switching power of up to 24 V DC/3 A, depending on  
the type  
IP67-protected fully encapsulated optical electronics  
Available with input or power solid-state relays as an  
option  
Integrated input circuit  
Solid-state relay can be replaced using an engagement  
lever  
Wear-resistant switching  
Resistant to vibrations and shocks  
Inflammability class V0 according to UL94  
Make sure you always use the latest documentation.  
It can be downloaded at www.download.phoenixcontact.com.  
A conversion table is available on the Internet at  
www.download.phoenixcontact.com/general/7000_en_00.pdf.  
This data sheet is valid for all products listed on the following page:  
PLC-OS…  
2
Ordering Data  
PLC INTERFACE With Screw Connection  
Description  
Type  
Order No.  
Pcs./Pck.  
PLC INTERFACE With Input Solid-State Relay, Universal Version  
PLC INTERFACE, comprising PLC-BSC... basic  
terminal block and plug-in miniature solid-state  
relay (see INTERFACE catalog), for mounting on  
3. Other input voltages on request.  
24 V DC PLCOSC- 24DC/48DC/100  
2966728  
2966744  
2966757  
10  
10  
10  
120 V AC/110 V DC PLCOSC-120UC/48DC/100  
1
230 V AC/220 V DC PLCOSC-230UC/48DC/100  
PLC INTERFACE With Power Solid-State Relay, Universal Version  
PLC INTERFACE, comprising PLC-BSC.../21  
basic terminal block and plug-in miniature solid-  
state relay (see INTERFACE catalog), for  
mounting on 3. Other input voltages on  
request.  
24 V DC PLCOSC- 24DC/24DC/2  
2966634  
2966650  
2966663  
10  
10  
10  
120 V AC/110 V DC PLCOSC-120UC/24DC/2  
1
230 V AC/220 V DC PLCOSC-230UC/24DC/2  
1
The PLC-ATP BK insulating plate must be installed for voltages greater than 250 V (L1, L2, L3) between the same terminal points on adjacent modules  
(see "Accessories"). FBST 8-PLC... or FBST 500... is then used for potential bridging.  
PLC INTERFACE With Spring-Cage Connection  
Description  
Type  
Order No.  
Pcs./Pck.  
PLC INTERFACE With Input Solid-State Relay, Universal Version  
PLC INTERFACE, comprising PLC-BSC... basic  
terminal block and plug-in miniature solid-state  
relay (see INTERFACE catalog), for mounting on  
3. Other input voltages on request.  
24 V DC PLCOSP- 24DC/48DC/100  
2967549  
2967552  
2967565  
10  
10  
10  
120 V AC/110 V DC PLCOSP-120UC/48DC/100  
1
230 V AC/220 V DC PLCOSP-230UC/48DC/100  
PLC INTERFACE With Power Solid-State Relay, Universal Version  
PLC INTERFACE, comprising PLC-BSC.../21  
basic terminal block and plug-in miniature solid-  
state relay (see INTERFACE catalog), for  
mounting on 3. Other input voltages on  
request.  
24 V DC PLCOSP- 24DC/24DC/2  
2967471  
2967484  
2967497  
10  
10  
10  
120 V AC/110 V DC PLCOSP-120UC/24DC/2  
1
230 V AC/220 V DC PLCOSP-230UC/24DC/2  
1
The PLC-ATP BK insulating plate must be installed for voltages greater than 250 V (L1, L2, L3) between the same terminal points on adjacent modules  
(see "Accessories"). FBST 8-PLC... or FBST 500... is then used for potential bridging.  
With the 120 V and 230 V modules, an OPT-60DC/... 60 V solid-state relay is normally used due to the input circuit integrated in the basic terminal  
block.  
For the protection of input and output, inductive loads must be dampened with an effective protective circuit.  
Accessories  
Description  
Insulating plate  
Type  
PLC-ATP BK  
Order No.  
2966841  
Pcs./Pck.  
25  
The PLC-ATP BK insulating plate should be used in the following cases: always fit at the start and end of a PLC terminal strip for voltages  
greater than 250 V (L1, L2, L3) between the same terminal points on adjacent modules (FBST 8-PLC... or FBST 500... can be used for  
potential bridging) and for safe isolation between adjacent modules.  
For additional accessories such as power terminal blocks and plug-in bridges, please refer to the INTERFACE catalog or www.phoenixcontact.com.  
103148_en_02  
PHOENIX CONTACT  
2
 
 
PLC-OS…  
3
Technical Data  
Input Data  
Nominal input voltage  
PLCOS...48DC/100  
PLCOS...24DC/2  
1
24 V DC  
120 V AC/110 V DC  
230 V AC/220 V DC  
24 V DC  
120 V AC/110 V DC  
230 V AC/220 V DC  
Permissible range (with reference to U  
Switching level  
)
0.8 ... 1.2 x U  
0.8 ... 1.1 x U  
0.8 ... 1.2 x U  
0.8 ... 1.1 x U  
N
N
N
N
N
1 signal ("H")  
0.8 x U  
0.4 x U  
8 mA  
0.8 x U  
0.3 x U  
4 mA  
0.8 x U  
0.4 x U  
9 mA  
0.8 x U  
N
N
N
N
N
N
N
0 signal ("L")  
0.25 x U  
4 mA  
N
Typical input current at U  
N
Typical response time at U  
20 μs  
6 ms  
20 μs  
6 ms  
N
Typical release time at U  
Transmission frequency f  
Input circuit  
300 μs  
300 Hz  
10 ms  
10 Hz  
Yellow LED, bridge  
rectifier  
300 μs  
300 Hz  
10 ms  
10 Hz  
Yellow LED, bridge  
rectifier  
N
limit  
Yellow LED,  
protection  
Yellow LED,  
protection  
against polarity  
reversal, free-  
wheeling diode  
against polarity  
reversal, free-  
wheeling diode  
1
The PLC-ATP BK insulating plate must be installed for voltages greater than 250 V (L1, L2, L3) between the same terminal points on adjacent modules  
(see "Accessories"). FBST 8-PLC... or FBST 500... is then used for potential bridging.  
Output Data  
PLCOS...48DC/100  
PLCOS...24DC/2  
Maximum switching voltage  
Minimum switching voltage  
Limiting continuous current  
Maximum inrush current  
Output configuration  
48 V DC  
33 V DC  
3 V DC  
100 mA  
3 A (see "Derating Curve")  
15 A (10 ms)  
2-wire floating  
Output circuit  
Protection against polarity reversal, surge protection  
Voltage drop at maximum limiting continuous current  
1 V  
200 mV  
General Data  
Impulse voltage withstand level  
Ambient temperature range  
Operation  
2.5 kV, 50 Hz, 1 min.  
-25°C ... 60°C  
-40°C ... 85°C  
100% operating factor  
V0  
Storage/transport  
Nominal operating mode  
Inflammability class according to UL 94 (housing)  
Standards/specifications  
1
IEC 60664, IEC 60664 A, DIN VDE 0110 (basic insulation)  
Pollution degree  
2
Surge voltage category  
Mounting position  
III  
Any  
Mounting  
Can be aligned without spacing  
Conductor cross-section  
Solid, with screw connection  
Stranded, with screw connection  
Solid, with spring-cage connection  
Stranded, with spring-cage connection  
Stripping length  
2
2
0.14 mm ... 2.5 mm (26 - 14 AWG)  
2
2
0.14 mm ... 1.5 mm (26 - 14 AWG)  
2
2
0.2 mm ... 2.5 mm (24 - 14 AWG)  
0.2 mm ... 1.5 mm (24 - 14 AWG)  
2
2
Screw connection  
10 mm  
Spring-cage connection  
Dimensions (W x H x D)  
Housing material  
8 mm  
6.2 mm x 94 mm x 80 mm  
Polyamide PA, green  
1
The PLC-ATP BK insulating plate must be installed for safe isolation between adjacent modules (see "Accessories"). FBST 8-PLC... or FBST 500... is  
then used for potential bridging.  
103148_en_02  
PHOENIX CONTACT  
3
PLC-OS…  
Tests/Approvals  
CE  
c
UL  
GL  
U u  
F
4
Block Diagram  
5
Derating Curve  
3
2
1
0
13+  
14  
A2  
A1  
1)  
1)  
The input circuit  
0
10  
20  
30  
40  
50  
60  
depends on the type  
Ambient temperature [°C]  
PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany • Phone: +49 - 52 35 - 30 0  
PHOENIX CONTACT • P.O.Box 4100 • Harrisburg • PA 17111-0100 • USA • Phone: +717-944-1300  
www.phoenixcontact.com  
103148_en_02  
4

相关型号:

2966786

Special Relay,
PHOENIX

2966812

Accessories for the PLC INTERFACE Series
PHOENIX

2966825

Strip Terminal Block, 1 Row(s), 1 Deck(s)
PHOENIX

2966838

Special Relay
PHOENIX

2966841

Accessories for the PLC INTERFACE Series
PHOENIX

2966906

Power/Signal Relay, SPDT, Momentary, 0.015A (Coil), 12VDC (Coil), 6A (Contact), 250VDC (Contact), DC Input, AC/DC Output, DIN-Rail Mount, ROHS COMPLIANT
PHOENIX

2967015

Modular Terminal Block
PHOENIX

2967028

Modular Terminal Block
PHOENIX

2967031

Modular Terminal Block
PHOENIX

2967044

Modular Terminal Block
PHOENIX

2967057

Modular Terminal Block
PHOENIX

2967060

Relays/Accessories,
PHOENIX