PLC-RS…/21
PLC INTERFACE With PDT Relay,
Universal Version
INTERFACE
Data Sheet
101780_en_02
© PHOENIX CONTACT - 03/2008
1.3
Optimum Use of Plug-In Bridges
1
Description
The PLC INTERFACE module achieves maximum
efficiency with the user-friendly FBST plug-in bridge system.
The PLC-RS…/21 makes effective use of the bridging
options for the A1/A2 connection on the coil side and for the
grouped power supply at connection 11 on the contact side.
Especially effective here are the 500 mm long color-
insulated continuous plug-in bridges that can easily be cut to
the required length and quickly inserted in the bridge shafts.
They eliminate the need for complicated and time-
consuming loop bridges.
PLC-RS…/21 relay modules, which can be used
universally, comprise 6.2 mm basic terminal blocks and
plug-in miniature relays with PDT contact and screw or
spring-cage connection.
1.1
PDT Offers a High Degree of Flexibility
The PLC-RS…/21 universal PDT module is used whenever
an application requires a high degree of flexibility. It can be
used either as an input or output module or in N/O, N/C or
PDT contact applications.
This offers the advantage of fewer ordering and
warehousing items. PLC INTERFACE modules are
supplied fully equipped with a relay as standard.
1.4
Additional Advantages
–
Operational safety with RT III (IP67)-protected
mechanics
–
–
Environmentally friendly, cadmium-free power contact
1.2
Input Voltages From 12 V to 230 V
material for loads up to 250 V AC/6 A
PLC-RS…/21 is available on the coil side in all common
industrial voltages from 12 V to 230 V. A further advantage
is the ready-integrated input circuit. It consists of a status
indicator as well as free-wheeling diode and polarity
reversal protection function, and ensures that the operating
state is displayed clearly, also offering reliable EMI
suppression for the coils and preventing destruction should
the polarity be accidentally reversed.
Available with gold coating for low power levels (mA) as
an option
Integrated input circuit
Relay can be replaced using an engagement lever
Safe isolation according to DIN EN 50178
Inflammability class V0 according to UL94
–
–
–
–
Make sure you always use the latest documentation.
It can be downloaded at www.download.phoenixcontact.com.
A conversion table is available on the Internet at
www.download.phoenixcontact.com/general/7000_en_00.pdf.
This data sheet is valid for all products listed on the following page:
PLC-RS…/21
Pcs./Pck.
2
Ordering Data
PLC INTERFACE With Screw Connection
Description
Type
Order No.
PLC INTERFACE With Multi-Layer Contact Relay, Universal Version
PLC INTERFACE, comprising PLC-BSC.../21
basic terminal block and plug-in miniature relay
(see INTERFACE catalog), for mounting on 3
12 V DC PLCRSC- 12DC/21AU
24 V DC PLCRSC- 24DC/21AU
2966919
2966265
2966278
2966126
2966142
2966281
2966294
10
10
10
10
10
10
10
24 V AC/DC PLCRSC- 24UC/21AU
48 V DC PLCRSC- 48DC/21AU
60 V DC PLCRSC- 60DC/21AU
120 V AC/110 V DC PLCRSC-120UC/21AU
1
230 V AC/220 V DC PLCRSC-230UC/21AU
PLC INTERFACE With Power Contact Relay, Universal Version
PLC INTERFACE, comprising PLC-BSC.../21
basic terminal block and plug-in miniature relay
(see INTERFACE catalog), for mounting on 3
12 V DC PLCRSC- 12DC/21
2966906
2966171
2966184
2966113
2966139
2966197
2966207
10
10
10
10
10
10
10
24 V DC PLCRSC- 24DC/21
24 V AC/DC PLCRSC- 24UC/21
48 V DC PLCRSC- 48DC/21
60 V DC PLCRSC- 60DC/21
120 V AC/110 V DC PLCRSC-120UC/21
1
230 V AC/220 V DC PLCRSC-230UC/21
1
The PLC-ATP BK insulating plate must be installed for voltages greater than 250 V (L1, L2, L3) between the same terminal points on adjacent modules
(see "Accessories"). FBST 8-PLC... or FBST 500... is then used for potential bridging.
PLC INTERFACE With Spring-Cage Connection
Description
Type
Order No.
Pcs./Pck.
PLC INTERFACE With Multi-Layer Contact Relay, Universal Version
PLC INTERFACE, comprising PLC-BSC.../21
basic terminal block and plug-in miniature relay
(see INTERFACE catalog), for mounting on 3
12 V DC PLCRSP- 12DC/21AU
24 V DC PLCRSP- 24DC/21AU
2967442
2966540
2966553
2966566
2966579
2966582
2966647
10
10
10
10
10
10
10
24 V AC/DC PLCRSP- 24UC/21AU
48 V DC PLCRSP- 48DC/21AU
60 V DC PLCRSP- 60DC/21AU
120 V AC/110 V DC PLCRSP-120UC/21AU
1
230 V AC/220 V DC PLCRSP-230UC/21AU
PLC INTERFACE With Power Contact Relay, Universal Version
PLC INTERFACE, comprising PLC-BSC.../21
basic terminal block and plug-in miniature relay
(see INTERFACE catalog), for mounting on 3
12 V DC PLCRSP- 12DC/21
2967439
2966472
2966485
2966498
2966511
2966524
2966537
10
10
10
10
10
10
10
24 V DC PLCRSP- 24DC/21
24 V AC/DC PLCRSP- 24UC/21
48 V DC PLCRSP- 48DC/21
60 V DC PLCRSP- 60DC/21
120 V AC/110 V DC PLCRSP-120UC/21
1
230 V AC/220 V DC PLCRSP-230UC/21
1
The PLC-ATP BK insulating plate must be installed for voltages greater than 250 V (L1, L2, L3) between the same terminal points on adjacent modules
(see "Accessories"). FBST 8-PLC... or FBST 500... is then used for potential bridging.
With the 120 V and 230 V modules, an REL-MR-60DC/... 60 V relay is normally used due to the input circuit integrated in the basic terminal block.
For the protection of input and output, inductive loads must be dampened with an effective protective circuit.
101780_en_02
PHOENIX CONTACT
2
PLC-RS…/21
Accessories
Description
Insulating plate
Type
PLC-ATP BK
Order No.
2966841
Pcs./Pck.
25
The PLC-ATP BK insulating plate should be used in the following cases: always fit at the start and end of a PLC terminal strip for voltages
greater than 250 V (L1, L2, L3) between the same terminal points on adjacent modules (FBST 8-PLC... or FBST 500... can be used for
potential bridging) and for safe isolation between adjacent modules.
For additional accessories such as power terminal blocks and plug-in bridges, please refer to the INTERFACE catalog or www.phoenixcontact.com.
3
Technical Data
Input Data
Nominal input voltage
...24DC...
24 V DC
...24UC...
24 V AC/DC
...120UC...
120 V AC/
110 V DC
...230UC...
230 V AC/
220 V DC
1
Permissible range (with reference to U
)
See "Operating Voltage Ranges" on page 5
N
Typical input current at U
Typical response time at U
9 mA
4 ms
8 ms
11 mA/8.5 mA
6 ms
3.5 mA/3 mA
6 ms
3 mA
7 ms
15 ms
N
N
Typical release time at U
Input circuit
15 ms
15 ms
N
Yellow LED,
protection
Yellow LED, bridge rectifier
against polarity
reversal, free-
wheeling diode
1
The PLC-ATP BK insulating plate must be installed for voltages greater than 250 V (L1, L2, L3) between the same terminal points on adjacent modules
(see "Accessories"). FBST 8-PLC... or FBST 500... is then used for potential bridging.
Output Data
PLC-...21
PLC-...21AU
Contact type
Single contact, SPDT
1
Contact material
AgSnO
AgSnO + 5 μA
2
Maximum switching voltage
Minimum switching voltage
Limiting continuous current
Maximum inrush current
Minimum switching current
Maximum shutdown power
250 V AC/DC
12 V AC/DC
6 A
30 V AC/36 V DC
100 mV
50 mA
50 mA
1 mA
30 A (for AC 15 operation)
10 mA
Ohmic load τ = 0 ms
140 W
Ohmic load τ = 0 ms
24 V DC
48 V DC
60 V DC
110 V DC
220 V DC
250 V AC
1.2 W
–
–
–
–
–
20 W
18 W
23 W
40 W
1500 VA
120 mW
Minimum switching power
1
10 μW
If the specified maximum values are exceeded, the gold coating will be damaged. In subsequent operation, the AgSnO contact values given here will
apply. This can then result in reduced service life, similar to dedicated power contacts.
2
The PLC-ATP BK insulating plate must be installed for voltages greater than 250 V (L1, L2, L3) between the same terminal points on adjacent modules
(see "Accessories"). FBST 8-PLC... or FBST 500... is then used for potential bridging.
General Data
Impulse voltage withstand level
Ambient temperature range
Operation
4 kV, 50 Hz, 1 min.
-25°C ... 60°C (230 V type -25°C ... 55°C)
Storage/transport
-40°C ... 85°C
100% operating factor
V0
Nominal operating mode
Inflammability class according to UL 94 (housing)
Mechanical service life
7
2 x 10 cycles
101780_en_02
PHOENIX CONTACT
3
PLC-RS…/21
General Data (Continued)
Air and creepage distances between the circuits
1
IEC 60664, IEC 60664 A, DIN VDE 0110, DIN EN 50178/VDE 0106-160,
IEC 60255/DIN VDE 0435
Pollution degree
3
Surge voltage category
Mounting position
III
Any
Mounting
Can be aligned without spacing
Conductor cross-section
Solid, with screw connection
Stranded, with screw connection
Solid, with spring-cage connection
Stranded, with spring-cage connection
Stripping length
2
2
0.14 mm ... 2.5 mm (26 - 14 AWG)
2
2
0.14 mm ... 1.5 mm (26 - 14 AWG)
2
2
0.2 mm ... 2.5 mm (24 - 14 AWG)
0.2 mm ... 1.5 mm (24 - 14 AWG)
2
2
Screw connection
10 mm
Spring-cage connection
Dimensions (W x H x D)
Housing material
8 mm
6.2 mm x 94 mm x 80 mm
Polyamide PA, green
1
The PLC-ATP BK insulating plate must be installed for safe isolation between adjacent modules (see "Accessories"). FBST 8-PLC... or FBST 500... is
then used for potential bridging.
Tests/Approvals
CE
UL
GL
c
U u
F
4
Block Diagram
11
14
A2
A1
1)
12
1)
The input circuit
depends on the type
101780_en_02
PHOENIX CONTACT
4
PLC-RS…/21
5
Operating Voltage Ranges
U
U
1,4
1,4
1,3
1,2
1,1
1
U
U
N
N
A
A
1,3
1,2
1,1
1
UN= 24 V DC
UN= 110V DC / 120V AC
0,9
0,8
0,7
0,9
0,8
0,7
B
B
20 25 30 35 40 45 50 55 60 65
20 25 30 35 40 45 50 55 60 65
C]
U
T
[
C]
T [
°
°
U
Figure 1
Operating voltage range for 24 V DC
Figure 3
Operating voltage range for 120 V AC/DC
U
U
1,4
U
N
1,4
U
N
A
1,3
1,2
1,1
1
1,3
1,2
1,1
1
A
UN= 24 V DC / 24 V AC
UN= 220V DC / 230V AC
0,9
0,8
0,7
0,9
0,8
0,7
B
B
20 25 30 35 40 45 50 55 60 65
C]
U
20 25 30 35 40 45 50 55 60 65
T
[
°
T
[ C]
°
U
Figure 2
Operating voltage range for 24 V AC/DC
Figure 4
Operating voltage range for 230 V AC/DC
General Conditions
Direct alignment in the block, all devices 100% operating
factor, horizontal or vertical mounting.
Curve A
Maximum permissible continuous voltage Umax with limiting
continuous current on the contact side
Curve B
Minimum permissible operate voltage Uop following pre-
excitation