2901416 [PHOENIX]

Special Relay;
2901416
型号: 2901416
厂家: PHOENIX CONTACT    PHOENIX CONTACT
描述:

Special Relay

文件: 总8页 (文件大小:167K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
PSR-...-42-48UC/ESAM4/3X1/1X2/B  
Safety relay for emergency stop and safety door  
monitoring  
Data sheet  
105315_en_02  
© PHOENIX CONTACT 2014-06-13  
1
Description  
The safety relay can be used in safety circuits according to  
Features  
EN 60240-1 and IEC 61508.  
Emergency stop and safety door monitoring  
Suitable up to category 4, PL e (EN ISO 13849-1),  
SILCL 3 (EN 62061)  
With this switching device, circuits are interrupted in a  
safety-oriented manner.  
Control is via a single channel or two channels, either with  
automatic or manual start circuit.  
Depending on the external wiring, up to category 4, PL e ac-  
cording to EN ISO 13849-1 or SILCL 3 according to  
EN 62061 can be achieved.  
The safety relay is equipped with three enabling current  
paths that drop out without delay corresponding to stop cat-  
egory 0 according to EN 60204-1.  
Optional plug-in screw or spring-cage terminal blocks  
Single-channel or two-channel wiring with cross-circuit  
detection  
3 enable current paths  
1 signaling current path  
WARNING: Risk of electric shock  
Observe the safety instructions in the corresponding section!  
Make sure you always use the latest documentation.  
It can be downloaded from the product at phoenixcontact.net/products.  
This data sheet is valid for all products listed on the following pages.  
PSR-...-42-48UC/ESAM4/3X1/1X2/B  
2
Table of contents  
1
Description .............................................................................................................................. 1  
Table of contents..................................................................................................................... 2  
Ordering data .......................................................................................................................... 3  
Technical data ......................................................................................................................... 3  
Basic circuit diagram ............................................................................................................... 5  
Derating................................................................................................................................... 5  
Safety notes............................................................................................................................. 6  
Operating and indication elements .......................................................................................... 7  
Diagnostics.............................................................................................................................. 7  
2
3
4
5
6
7
8
9
10  
Application examples .............................................................................................................. 8  
10.1 Two-channel emergency stop circuit with cross-circuit detection ..................................................... 8  
10.2 Single-channel emergency stop circuit...................................................................................... 8  
105315_en_02  
PHOENIX CONTACT  
2
PSR-...-42-48UC/ESAM4/3X1/1X2/B  
3
Ordering data  
Description  
Type  
Order No.  
Pcs. / Pkt.  
Safety relay for emergency stop and safety door monitoring up to SIL 3 or PSR-SCP-42-48UC/ESAM4/3X1/  
Cat. 4, PL e according to EN ISO 13849, single or two-channel operation, 1X2B  
3 enabling current paths, nominal input voltage of 42 ... 48 V AC/DC, plug-  
in screw terminal blocks.  
2901416  
1
Safety relay for emergency stop and safety door monitoring up to SIL 3 or PSR-SPP-42-48UC/ESAM4/3X1/  
Cat. 4, PL e according to EN ISO 13849, single or two-channel operation, 1X2B  
3 enabling current paths, nominal input voltage of 42 ... 48 V AC/DC, plug-  
in spring-cage terminal blocks.  
2901417  
1
Documentation  
Type  
Order No.  
Pcs. / Pkt.  
User manual, English, for applications for PSR safety relay  
UM EN SAFETY RELAY APPLICA-  
2888712  
1
TION  
4
Technical data  
Input data  
Input voltage range  
42 V AC/DC ... 48 V AC/DC  
Input voltage range (factor)  
0.85 ... 1.1  
95 mA  
Typical input current  
Voltage at input/start and feedback circuit  
Max. permissible overall conductor resistance  
~ 24 V DC  
50  
(Input and reset circuit at U  
Typical response time  
Typical release time  
Recovery time  
)
N
40 ms (man. start)  
90 ms (when controlled via A1)  
1 s  
Operating voltage display  
Status display  
Green LED  
Green LED  
Protective circuit  
Surge protection Suppressor diode  
Output data  
Contact type  
3 enabling current paths  
1 signaling current path  
Contact material  
AgSnO , + 0.2 µm Au  
2
Minimum switching voltage  
Maximum switching voltage  
Limiting continuous current  
Maximum inrush current  
Inrush current, minimum  
Sq. Total current  
10 V AC/DC  
250 V AC/DC  
6 A (N/O contact)  
6 A  
10 mA  
2
2
2
2
2
72 A (I  
= I + I + I )  
1 2 3  
TH  
(see derating curve)  
Interrupting rating (ohmic load) max.  
144 W (24 V DC, τ = 0 ms)  
230 W (48 V DC, τ = 0 ms)  
68 W (110 V DC, τ = 0 ms)  
88 W (220 V DC, τ = 0 ms)  
2000 VA (250 V AC, τ = 0 ms)  
Maximum interrupting rating (inductive load)  
48 W (24 V DC, τ = 40 ms)  
40 W (48 V DC, τ = 40 ms)  
35 W (110 V DC, τ = 40 ms)  
33 W (220 V DC, τ = 40 ms)  
Switching capacity min.  
Mechanical service life  
100 mW  
7
Approx. 10 cycles  
105315_en_02  
PHOENIX CONTACT  
3
PSR-...-42-48UC/ESAM4/3X1/1X2/B  
Output data  
Switching capacity (360/h cycles)  
6 A (24 V DC)  
5 A (230 V AC)  
Switching capacity (3600/h cycles)  
Output fuse  
3 A (24 V (DC13))  
3 A (230 V (AC 15))  
10 A gL/gG NEOZED (N/O contact)  
6 A gL/gG NEOZED (N/C contact)  
General data  
Relay type  
Electromechanically forcibly guided, dust-proof relay.  
Nominal operating mode  
100% operating factor  
Degree of protection  
IP20  
Min. degree of protection of inst. location  
Mounting position  
IP54  
any  
Air and creepage distances between the power circuits  
Rated surge voltage / insulation  
DIN EN 50178/VDE 0160  
4 kV / basic insulation (safe isolation, reinforced insulation, and 6 kV between A1-  
A2/logic/enabling and signaling current paths)  
Dimensions  
Screw connection  
Spring-cage connection  
W x H x D  
22.5 x 99 x 114.5 mm  
22.5 x 112 x 114.5 mm  
Connection data  
Screw connection  
0.2 mm² ... 2.5 mm²  
0.2 mm² ... 2.5 mm²  
24 ... 12  
Spring-cage connection  
0.2 mm² ... 1.5 mm²  
0.2 mm² ... 1.5 mm²  
24 ... 16  
Conductor cross section, solid  
Conductor cross section, stranded  
Conductor cross section AWG/kcmil  
Ambient conditions  
Ambient temperature (operation)  
-25 °C ... 55 °C  
-40 °C ... 85 °C  
75 %  
Ambient temperature (storage/transport)  
Max. permissible relative humidity (operation)  
Max. permissible humidity (storage/transport)  
75 %  
Certification / Approvals  
Approvals  
   
Safety data  
Stop category according to IEC 60204  
0
Safety parameters for IEC 61508 - High demand  
SIL  
3
Demand rate  
Proof test interval  
< 12 Months  
240 Months  
Safety parameters for IEC 61508 - Low demand  
SIL  
3
Proof test interval  
Duration of use  
78 Months  
240 Months  
Safety characteristic data according to EN ISO 13849  
Category  
4
e
Performance level  
105315_en_02  
PHOENIX CONTACT  
4
PSR-...-42-48UC/ESAM4/3X1/1X2/B  
5
Basic circuit diagram  
6
Derating  
S11 S12 S34  
13  
23  
33  
41  
A1  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
72  
U Logic  
K1  
K2  
IN 1/2  
Logic  
Power  
AC/DC  
0
10  
20  
30  
40 45 50 55 60  
TA C]  
S21  
S22  
14  
24  
34  
42  
A2  
Figure 1  
Block diagram  
Figure 2  
Derating curve  
Key:  
Designation Explanation  
A1/A2  
S11/S12  
S21/S22  
S34  
Safety relay input voltage  
Safety sensor/switch 1 input circuit  
Safety sensor/switch 2 input circuit  
Start circuit  
13/14  
23/24  
33/34  
41/42  
Undelayed enabling current path 1  
Undelayed enabling current path 2  
Undelayed enabling current path 3  
Signaling current path  
105315_en_02  
PHOENIX CONTACT  
5
PSR-...-42-48UC/ESAM4/3X1/1X2/B  
7
Safety notes  
NOTE: Risk of damage to equipment due  
to incorrect installation  
For reliable operation, the safety relay must  
be installed in housing protected from dust  
and humidity (IP54).  
Carry out wiring according to the application.  
Refer to the “Application examples” section  
for this.  
WARNING: Risk of electric shock  
During operation, parts of electrical switching  
devices carry hazardous voltages.  
Before working on the switching device, dis-  
connect the power.  
Please observe the safety regulations of elec-  
trical engineering and industrial safety and lia-  
bility associations!  
Disregarding these safety regulations may re-  
sult in death, serious personal injury or dam-  
age to equipment.  
Startup, mounting, modifications, and up-  
grades should only be carried out by a skilled  
electrical engineer!  
NOTE: Risk of damage to equipment due  
to noise emissions  
When operating relay modules the operator  
must meet the requirements for noise emis-  
sion for electrical and electronic equipment  
(EN 61000-6-4) on the contact side and, if re-  
quired, take appropriate measures.  
WARNING: Risk of automatic machine re-  
start!  
For emergency stop applications, the ma-  
chine must be prevented from restarting auto-  
matically by a higher-level control system.  
Protective covers must not be removed when  
operating electrical switching devices.  
WARNING: Risk of automatic machine re-  
start!  
When using the manual reset function with  
monitored start, the “cross-circuit between  
S21/S22 and the cable from the reset button  
to S34” error must be prevented by design-re-  
lated measures, especially for safety func-  
tions with increased risk potential (see  
EN ISO 13849-2).  
WARNING: Danger due to faulty devices!  
The devices may be damaged following an er-  
ror and correct operation can no longer be en-  
sured.  
In the event of an error, replace the device im-  
mediately.  
Repairs to the device, especially if the hous-  
ing must be opened, may only be carried out  
by the manufacturer or authorized persons.  
Otherwise the warranty is invalidated.  
105315_en_02  
PHOENIX CONTACT  
6
PSR-...-42-48UC/ESAM4/3X1/1X2/B  
8
Operating and indication elements  
12  
11  
12  
11  
13  
10  
10  
13  
9
9
8
2
8
2
S11  
S12  
7
A
1
7
A
S21  
1
S
1
1
A
2
S
1
S22  
A
2
S
1
1
2
S
1
2
6
S
2
S
3
4
1
S
2
C
U
6
S
3
4
S
2
1
C
U
2
S
2
2
8V  
V
4
Power  
8
4
4
Power  
M
4
A
M
S
S33  
I
A
N
-E  
S
I
N
R
1/2  
5
-E  
S
K1  
R
S
1/2  
P
5
K1  
P
K2  
K2  
4
1
41  
4
2
3
3
4
2
3
3
3
4
1
3
3
4
1
3
2
3
1
4
2
3
1
4
A
A
I
4
2
2
4
N
P
P
2
.
4
2
4
C
A
ROVAL  
O
2
41  
4
N
1
B
.
33  
3
3
.
I
PNU  
13  
1
3
S
S
14  
T
O
1
4
U
TÜVRh  
M
T
0
.0O  
UP  
R
0.O  
/
T
T
1
p(  
3
3
:
ei  
p(  
s
3
24  
p
land  
42  
r
e
a
r
:
i
n
d
c
4
R
n
r
Fun  
g
han  
aMxAmb  
c
c
Typ  
l
e
n
d
c
c
/
R
n
d
n
(
42  
c
c
yTp  
h
e
c
2
e
t
c
oi  
4
l
(
Ap  
e
34  
2
c
D
C
)
U
nal  
)
4
e
t
o
e
:
1
3
0℃  
)l  
p
e
23  
4
ie  
:
1
0mA  
l
)
o
S
 5
nRat  
2
0mA  
)
24  
f
3
:
2
v
e
d
o
S
A
e
2
4
f
ty  
v
e
d
i
n
e
1
yt  
g
m0A  
1
m0A  
41  
,05A  
m0A  
31  
31  
32  
32  
41  
3
41  
3
42  
42  
14  
4
34  
43  
24  
24  
1
1
Figure 3  
PSR-SCP-42-48UC/ESAM4/3X1/1X2/B and PSR-SPP-42-48UC/ESAM4/3X1/1X2/B  
Key:  
Designation Explanation  
1
Metal lock for mounting on the DIN rail  
2
3
4
5
COMBICON plug-in screw terminal blocks  
COMBICON plug-in spring-cage terminal blocks  
13/14, 23/24, 33/34 - enabling current paths  
41/42 signaling current path  
6
7
8
9
10  
11  
12  
13  
LED status indicator, green - K1  
LED status indicator, green - K2  
LED status indicator, green - IN 1/2  
LED status indicator, green - Power  
S11/S12 - input circuit  
S21/S22 - input circuit  
Power supply  
S34 - start circuit  
9
Diagnostics  
The diagnostic descriptions can be found in Section 7 of the  
application manual for PSR safety relays.  
105315_en_02  
PHOENIX CONTACT  
7
PSR-...-42-48UC/ESAM4/3X1/1X2/B  
10.2 Single-channel emergency stop circuit  
10 Application examples  
Automatic activation with connection at S22-S34  
Suitable up to category 1, PL c (EN ISO 13849-1),  
SILCL 1 (EN 62061)  
10.1 Two-channel emergency stop circuit with  
cross-circuit detection  
Manual activation with connection at S12-S34  
Suitable up to category 4, PL e (EN ISO 13849-1),  
SILCL 3 (EN 62061)  
42-48V  
60V  
120V  
230V  
AC/DC  
42-48V  
60V  
120V  
230V  
AC/DC  
S1  
S1  
A1  
A2  
S11 S12 S21 S22  
13 23  
14 24  
33 41  
34 42  
K3  
K3  
K4  
(+)  
(
)
(GND)  
( )  
PSR-...-...UC/ESAM4/3x1/1x2/B  
)
(
S34  
K4  
13 23  
14 24  
A1  
A2  
S11 S12 S21 S22  
33 41  
34 42  
K3  
K3  
K4  
K3  
K4  
M
PSR-...-...UC/ESAM4/3x1/1x2/B  
S34  
K4  
K3  
K4  
Reset  
M
S2  
M
(N)  
Figure 5  
Emergency stop with automatic start  
M
(N)  
Figure 4  
Emergency stop with cross-circuit detection  
and manually monitored reset  
PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany  
phoenixcontact.com  
105315_en_02  
8

相关型号:

2901417

Special Relay
PHOENIX

2901422

Special Relay
PHOENIX

2901485

Off-Delay Relay, Momentary, 24VDC (Coil), 0.1s Adj Min, 10s Adj Max, DIN-Rail Mount,
PHOENIX

2901486

Off-Delay Relay, Momentary, 24VDC (Coil), 0.3s Adj Min, 300s Adj Max, DIN-Rail Mount,
PHOENIX

2901538

RAD-PT100-4-IFS
PHOENIX

2901540

RAD-PT100-4-IFS
PHOENIX

2901541

RAD-PT100-4-IFS
PHOENIX

2901543

BRIDGE- 2-3M
PHOENIX

2901604

Round cable - VIP-CAB-FLK14/AXIO/0,14/0,5M
PHOENIX

2901605

VIP-CAB-FLK14/AXIO/0 14/1 0M
PHOENIX

2901606

VIP-CAB-FLK14/AXIO/0 14/1 5M
PHOENIX

2901607

Round cable - VIP-CAB-FLK14/AXIO/0,14/2
PHOENIX