2834148 [PHOENIX]

暂无描述;
2834148
型号: 2834148
厂家: PHOENIX CONTACT    PHOENIX CONTACT
描述:

暂无描述

文件: 总5页 (文件大小:108K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
PR2 Relay Base for:  
– Industrial DPDT or 4PDT Relays  
Universal Modular System  
The 27 mm*) (1.063 in.) wide PR2 relay base range  
is a modular system consisting of PR2-B...relay bases,  
robust REL-IR... electromechanical industrial relays  
with DPDT and 4PDT contacts, and a comprehensive  
range of accessories. These include:  
– Plug-in input/interference suppression modules  
– Relay retaining bracket with labeling field and eject  
function  
c
– Labels  
– Continuous jumpers  
Depending on the application, complete coupling  
relays can be created, which are optimized in terms of  
cost and function.  
3
Base Versions  
2
The relay bases are available in three versions - the  
at 2/2 level PR2-BSC2 type with screw connections,  
and the "logical" 1/3 level PR2-BSC3 with screw  
connections and PR2-BSP3 with spring-cage  
connections.The logical versions have coil and contact  
connections that are located opposite one another and  
thus meet the requirements of modern control cabinet  
concepts with clear isolation of control signals and  
1
b
1 2 3  
PR2-BSC3... PR2-BSP3...  
PR2-BSC2...  
Nominal voltage U1)  
Nominal current I1)  
300 V AC  
12 A  
300 V AC  
12 A  
300 V AC  
10 A  
load.  
Robust, Cost-Effective Industrial Relays  
Industrial relays are used in many sectors of industry  
due to their robust structure, which has 2.6 mm  
(0.102 in.) at pins. The main features of the REL/IR...  
series include the fully automated manufacture of  
products in conjunction with the high degree of product  
stability and global availability. The following versions  
are available:  
Conductor cross  
section  
– Solid  
– Flexible  
American Wire Gauge 2 x 14 AWG  
2 x 2.5 mm2  
2 x 2.5 mm2  
2 x 2.5 mm2 2 x 1.5 mm2  
2 x 2.5 mm2 2 x 1.5 mm2  
2 x 14 AWG  
2 x 16 AWG  
Connection type  
3
)
M 3  
M 3  
Approvals2)  
C A  
C A  
C A  
– With two 10 A 2PDT contacts  
– With four 5 A 4PDT contacts  
Stripping length  
8 mm (0.31 in.)  
12 mm (0.47 in.)  
8 mm (0.31 in.)  
– In all popular AC and DC coil voltages  
Considerably wider and more expensive miniature  
contactors can thus be replaced cost-effectively in  
many applications without adversely affecting machine  
or system operation. All industrial relays have the  
following standard features:  
– Manual test key (AC coil = red key, DC coil = blue  
key)  
– Mechanical switch setting display  
Height (a) with  
retaining bracket:  
– EL2-P35  
84 mm  
(3.307 in.)  
75 mm  
(2.953 in.)  
27 mm  
(1.063 in.)  
86 mm  
84 mm  
(3.307 in.)  
95 mm  
(3.740 in.)  
31 mm  
(1.220 in.)  
(3.386 in.)  
78.5 mm  
(3.091 in.)  
27 mm  
Depth (b)  
Width (c)  
(1.063 in.)  
Ambient temperature  
-25°C...+85°C -25°C...+85°C -25°C...+85°C  
(-13°F...  
+185°F)  
(-13°F...  
+185°F)  
(-13°F...  
+185°F)  
– LED status indicators  
Free-wheeling diode (only DC types)  
– Power contacts with solid gold coating (only types  
with 4PDT contacts)  
1) The maximum electrical data is relay dependent.  
2) Details on request.  
3) Two spring-cage connections per terminal point.  
*) Spring-cage version is 31 mm (1.220 in.) wide  
Phoenix Contact GmbH & Co. KG • 32825 Blomberg, Germany  
Phone +49 - 52 35 - 30 0 • Fax +49 - 52 35 - 34 12 00 • www.phoenixcontact.com  
Local Contact: www.phoenixcontact.com/salesnetwork  
Phoenix Contact page 1 of 5  
for mounting on  
10 pcs. per pack  
                                                               
,including MP2 markers,  
PR2-BSC3/4x21  
PR2-BSP3/4x21  
EL2-P35  
28 33 57 6  
28 33 58 9  
28 33 59 2  
for mounting on  
                                                               
, including MP1 mar-  
for mounting on  
                                                               
, including MP2 mar-  
PR2-BSC2/4x21  
10  
10  
10  
10  
PR2 Relay Base for Industrial DPDT or 4PDT Relays  
Pcs.  
Pkt.  
Description  
Type  
Order No.  
28 33 56 3  
PR2-B relay base, for REL-IR Industrial  
DPDT or 4PDT Relays, 2/2 level version,  
screw connections, optional connection of  
input/interference suppression module,  
3
kers, 10 pcs. per pack  
PR2-B relay base, for REL-IR Industrial  
DPDT or 4PDT Relays, 1/3 level version,  
screw connections, optional connection of  
input/interference suppression module,  
3
PR2-B relay base, for REL-IR Industrial  
DPDT or 4PDT Relays, 1/3 level version,  
spring-cage connections, optional connection  
of input/interference suppression module,  
3
kers, 10 pcs. per pack  
Relay retaining bracket, with eject function  
and integrated device marking area  
(8 x 25 mm [0.315 x 0.984 in.]), suitable for  
PR2 relay base:  
– For 35 mm (1.378 in.) high industrial relays  
Device marker:  
– Suitable for PR2-BSP,  
6 x 15 mm (0.236 x 0.591 in.) marking area  
– Suitable for PR2-BSC,  
9 x 25 mm (0.354 x 0.984 in.) marking area  
MP1  
MP2  
28 33 63 1  
28 33 64 4  
10  
10  
Plug-in module, for mounting on PR1 and  
PR2, with free-wheeling diode and yellow  
LED, polarity: A1 +, A2 –  
Input voltage:  
– 12 - 24 V DC ±20%  
– 48 - 60 V DC ±20%  
LDP-12-24DC1)  
LDP-48-60DC1)  
LDP-110DC1)  
28 33 65 7  
28 33 66 0  
28 33 67 3  
10  
10  
10  
-
A
2
+
A
1
– 110 V DC ±20%  
Plug-in module, for mounting on PR1 and  
PR2, with free-wheeling diode and yellow  
LED, polarity: A1 –, A2 + (Japanese standard)  
Input voltage:  
– 12 - 24 V DC ±20%  
– 48 - 60 V DC ±20%  
LDM-12-24DC1)  
LDM-48-60DC1)  
LDM-110DC1)  
28 33 68 6  
28 33 69 9  
28 33 70 9  
10  
10  
10  
+
A
2
-
A
1
– 110 V DC ±20%  
Plug-in module, for mounting on PR1 and  
PR2, with varistor and yellow LED, input  
voltage:  
– 12 - 24 V AC/DC ±20%  
– 48 - 60 V AC/DC ±20%  
– 120 - 230 V AC/110 V DC ±20%  
LV-12-24UC  
LV-48-60UC  
LV-120-230AC/110 DC  
(30 V varistor)  
(75 V varistor)  
(275 V varistor)  
28 33 71 2  
28 33 72 5  
28 33 73 8  
10  
10  
10  
A
2
A
1
Plug-in module, for mounting on PR1 and  
PR2, with varistor  
Input voltage:  
– 12 - 24 V AC/DC ±20%  
– 48 - 60 V AC/DC ±20%  
– 120 - 230 V AC/DC ±20%  
V-12-24UC  
V-48-60UC  
V-120-230UC  
(30 V varistor)  
(75 V varistor)  
(275 V varistor)  
28 33 86 4  
28 33 87 7  
28 33 88 0  
10  
10  
10  
A
2
A
1
Plug-in module, for mounting on PR1 and  
PR2, with RC element  
Input voltage:  
– 12 - 24 V AC/DC ±20%  
– 48 - 60 V AC/DC ±20%  
– 120 - 230 V AC/DC ±20%  
RC-12-24UC  
RC-48-60UC  
RC-120-230UC  
(220 nF/100 )  
(220 nF/220 )  
(100 nF/470 )  
28 33 74 1  
28 33 75 4  
28 33 76 7  
10  
10  
10  
A
2
A
1
Wire jumper, 50-pos., can be separated,  
maximum jumpering distance of 60 mm  
(2.36 in.), 0.5 mm2 (20 AWG), insulation:  
– Blue  
– Black  
– Gray  
DB 50-90 BU  
DB 50-90 BK  
DB 50-90 GY  
28 21 18 0  
28 20 91 6  
28 20 92 9  
1
1
1
1)Might not be required, as LED and free-  
wheeling diode are already integrated in  
the REL-IR/LD... relays.  
Phoenix Contact page 2 of 5  
Plug-In Industrial Relays With DPDT Contacts, Suitable for PR2 Relay Base  
Pcs.  
Pkt.  
Description  
Type  
Order No.  
Plug-in industrial relays1) with power  
contacts, DPDT contacts, test key, status  
LED, free-wheeling diode, mechanical  
switch setting display, polarity: A1 +, A2 –  
Coil voltage:  
12 V DC  
24 V DC  
48 V DC  
REL-IR/LDP-12DC/2x21  
REL-IR/LDP-24DC/2x21  
REL-IR/LDP-48DC/2x21  
REL-IR/LDP-110DC/2x21  
28 34 01 2  
28 34 02 5  
28 34 03 8  
28 34 04 1  
10  
10  
10  
10  
2
1
2
4
2
2
– 110 V DC  
A
1
Plug-in industrial relays1) with power  
contacts, DPDT contacts, test key, status  
LED, free-wheeling diode, mechanical  
switch setting display, polarity: A1 –, A2 +  
(Japanese standard)  
A
2
1
1
1
4
1
2
Representation without  
LED and free-wheeling  
diode.  
Coil voltage:  
12 V DC  
24 V DC  
48 V DC  
REL-IR/LDM-12DC/2x21  
REL-IR/LDM-24DC/2x21  
REL-IR/LDM-48DC/2x21  
REL-IR/LDM-110DC/2x21  
28 34 15 1  
28 34 16 4  
28 34 17 7  
28 34 18 0  
10  
10  
10  
10  
Contacts 21, 22, and 24  
are led to relay base  
connections 41, 42, and  
44.  
– 110 V DC  
Plug-in industrial relays1) with power  
contacts, DPDT contacts, test key, status  
LED, mechanical switch setting display  
Coil voltage:  
24 V AC  
REL-IR/L-24AC/2x21  
REL-IR/L-120AC/2x21  
REL-IR/L-230AC/2x21  
28 34 05 4  
28 34 06 7  
28 34 07 0  
10  
10  
10  
– 120 V AC  
– 230 V AC  
Technical Data  
Coil Side DC Coils  
Nominal input voltage UN  
12 V DC  
See diagram on page 5  
75 mA  
13 ms  
5 ms  
24 V DC  
48 V DC  
110 V DC  
Permissible range (with reference to UN)  
Typical input current at UN  
Typical response time at UN  
Typical release time at UN  
DC coil resistance at 20°C (68°F)  
38 mA  
13 ms  
5 ms  
19 mA  
13 ms  
5 ms  
2560 ±15%  
10 mA  
13 ms  
5 ms  
160 ±15% 630 ±15%  
11100 ±15%  
Coil Side AC Coils (50 Hz/60 Hz)  
Nominal input voltage UN  
Permissible range (with reference to UN)  
Typical input current at UN (50 Hz/60 Hz)  
Typical response time at UN (depending on phase relation)  
Typical release time at UN (depending on phase relation)  
DC coil resistance at 20°C (68°F)  
24 V AC 120 V AC  
See diagram on page 5  
54 mA/46 mA 11 mA/9 mA  
230 V AC  
5 mA/4 mA  
4 - 10 ms  
3 - 12 ms  
4 - 10 ms  
3 - 12 ms  
180 ±15%  
4 - 10 ms  
3 - 12 ms  
4430 ±15% 18790 ±15%  
Contact Side  
REL-IR...2x21  
Contact type  
Single contact, 2 PDT contacts  
Contact material  
Ag  
Maximum switching voltage  
Minimum switching voltage  
Limiting continuous current  
Maximum inrush current  
Minimum switching current  
Maximum shutdown power (ohmic load)  
250 V AC/125 V DC  
5 V  
10 A  
20 A (15 ms)  
1 mA  
2500 VA  
250 V AC  
For additional data, see diagram on page 5  
5 mW  
Minimum switching power  
General Data  
Test voltage:  
Winding/contact  
Contact/contact  
2 kV, 50 Hz, 1 minute  
2 kV, 50 Hz, 1 minute  
Ambient temperature  
Nominal operating mode  
Mechanical service life  
Electrical service life  
-55°C to +70°C (-67°F to +158°F)  
100% ED  
5 x 107 cycles  
See diagram on page 5  
Standards/specications  
IEC 60 664/IEC 60 664 A/DIN VDE 0110,  
degree of pollution 2, Surge Voltage Category II  
UL; CSA; VDE  
Approvals  
Mounting position/mounting  
Any/can be mounted without spacing  
1)Further voltage versions, lockable test key, etc. on request.  
Phoenix Contact page 3 of 5  
Plug-In Industrial Relays With 4PDT Contacts, Suitable for PR2 Relay Base  
Pcs.  
Pkt.  
Description  
Type  
Order No.  
Plug-in industrial relays1) with power  
contacts and solid gold coating, 4PDT  
contacts, test key, status LED, free-  
wheeling diode, mechanical switch setting  
display, polarity: A1 +, A2 –  
Coil voltage:  
12 V DC  
24 V DC  
48 V DC  
REL-IR/LDP-12DC/4x21AU  
REL-IR/LDP-24DC/4x21AU  
REL-IR/LDP-48DC/4x21AU  
REL-IR/LDP-110DC/4x21AU  
28 34 08 3  
28 34 09 6  
28 34 10 6  
28 34 11 9  
10  
10  
10  
10  
4
1
4
4
4
2
A
1
3
1
3
4
3
2
– 110 V DC  
2
1
1
1
2
1
4
4
2
1
2
2
A
2
Plug-in industrial relays1) with power  
contacts and solid gold coating, 4PDT  
contacts, test key, status LED, free-  
wheeling diode, mechanical switch setting  
display, polarity: A1 –, A2 + (Japanese  
standard)  
Representation without  
LED and free-wheeling  
diode.  
Coil voltage:  
12 V DC  
24 V DC  
48 V DC  
REL-IR/LDM-12DC/4x21AU  
REL-IR/LDM-24DC/4x21AU  
REL-IR/LDM-48DC/4x21AU  
REL-IR/LDM-110DC/4x21AU  
28 34 19 3  
28 34 20 3  
28 34 21 6  
28 34 22 9  
10  
10  
10  
10  
– 110 V DC  
Plug-in industrial relays1) with power  
contacts and solid gold coating, 4PDT  
contacts, test key, status LED, mechanical  
switch setting display  
Coil voltage:  
24 V AC  
REL-IR/L-24AC/4x21AU  
REL-IR/L-120AC/4x21AU  
REL-IR/L-230AC/4x21AU  
28 34 12 2  
28 34 13 5  
28 34 14 8  
10  
10  
10  
– 120 V AC  
– 230 V AC  
Technical Data  
Coil Side DC Coils  
Nominal input voltage UN  
12 V DC  
See diagram on page 5  
75 mA  
13 ms  
5 ms  
24 V DC  
48 V DC  
110 V DC  
Permissible range (with reference to UN)  
Typical input current at UN  
Typical response time at UN  
Typical release time at UN  
DC coil resistance at 20°C (68°F)  
38 mA  
13 ms  
5 ms  
19 mA  
13 ms  
5 ms  
2560 ±15%  
10 mA  
13 ms  
5 ms  
160 ±15% 630 ±15%  
11100 ±15%  
Coil Side AC Coils (50 Hz/60 Hz)  
Nominal input voltage UN  
Permissible range (with reference to UN)  
Typical input current at UN (50 Hz/60 Hz)  
Typical response time at UN (depending on phase relation)  
Typical release time at UN (depending on phase relation)  
DC coil resistance at 20°C (68°F)  
24 V AC 120 V AC  
See diagram on page 5  
54 mA/46 mA 11 mA/9 mA  
230 V AC  
5 mA/4 mA  
4 - 10 ms  
3 - 12 ms  
4 - 10 ms  
3 - 12 ms  
180 ±15%  
4 - 10 ms  
3 - 12 ms  
4430 ±15% 18790 ±15%  
Contact Side  
REL-IR...4x21AU  
Contact type  
Single contact, 4 PDT contacts  
Contact material  
AgNi + 3 µ Au  
Maximum switching voltage  
Minimum switching voltage  
Limiting continuous current  
Maximum inrush current  
Minimum switching current  
Maximum shutdown power (ohmic load)  
250 V AC/125 V DC  
1 V  
5 A  
12 A (15 ms)  
1 mA  
1250 VA  
250 V AC  
For additional data, see diagram on page 5  
1 mW  
Minimum switching power  
General Data  
Test voltage:  
Winding/contact  
Contact/contact  
2 kV, 50 Hz, 1 minute  
2 kV, 50 Hz, 1 minute  
Ambient temperature  
Nominal operating mode  
Mechanical service life  
Electrical service life  
-55°C to +70°C (-67°F to +158°F)  
100% ED  
5 x 107 cycles  
See diagram on page 5  
Standards/specications  
IEC 60 664/IEC 60 664 A/DIN VDE 0110,  
degree of pollution 2, Surge Voltage Category II  
UL; CSA; VDE  
Approvals  
Mounting position/mounting  
Any/can be mounted without spacing  
1)Further voltage versions, lockable test key, etc. on request.  
Phoenix Contact page 4 of 5  
Diagrams for REL-IR... Industrial Relays  
REL-IR...2x21 (DPDT Contacts)  
Operating voltage range  
Shutdown power  
Electrical service life  
Tu = Tcoil  
1
1
1
1
,
,
,
,
8
6
4
2
1
2
1
0
1
1
0
5
6
1
0
2
2
3
1
3
4
5
1
0
0
0
,
,
5
3
0
,
8
4
1
0
0
,
6
0
,
1
0
2
4
6
8
1
0
0
1
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
1
0
2
0
0
5
0
7
0
1
0
0
2
0
3
0
0
Ambient temperature [°C]  
3 Switching voltage [V] 0  
Switching current [A]  
1 AC, ohmic load  
1 250 V AC, ohmic load  
2 30 V DC, ohmic load  
2 AC, cos ϕ = 0.4  
3 DC, ohmic load  
4 DC, L/R = 7 ms  
REL-IR...4x21AU (4PDT Contacts)  
Operating voltage range  
Shutdown power  
Electrical service life  
Tu = Tcoil  
1
1
1
1
,
,
,
,
8
6
4
2
1
2
1
0
1
0
5
6
1
0
1
2
2
3
1
3
4
5
1
0
0
0
,
,
5
3
0
,
8
4
1
0
0
,
6
0
,
1
0
1
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
0
1
2
3
4
5
1
0
2
0
3
0
5
0
7
0
1
0
0
2
0
0
3
0
0
Ambient temperature [°C]  
Switching voltage [V]  
Switching current [A]  
1 AC, ohmic load  
2 AC, cos ϕ = 0.4  
3 DC, ohmic load  
4 DC, L/R = 7 ms  
1 250 V AC, ohmic load  
2 30 V DC, ohmic load  
Phoenix Contact page 5 of 5  

相关型号:

2834203

Power/Signal Relay
PHOENIX

2834229

RELAY GEN PURPOSE
PHOENIX

2834258

Power/Signal Relay
PHOENIX

2834274

Power/Signal Relay,
PHOENIX

2834290

Power/Signal Relay
PHOENIX

2834478

General Purpose / Industrial Relays PR1RSP3LV230AC/21AU 50MA 230VAC SPDT SPG
PHOENIX

2834821

RELAY GEN PURPOSE
PHOENIX

2834834

Power/Signal Relay
PHOENIX

2834847

Power/Signal Relay
PHOENIX

2834876

Power/Signal Relay
PHOENIX

2834973

REL-IR/LDP-220DC/4X21AU
PHOENIX

2835

85 MHz differential notch filter
KR