TMC  
Thermomagnetic circuit breaker  
for mounting on a DIN rail  
Data sheet  
100695_en_03  
© PHOENIX CONTACT 2012-03-09  
t [s]  
1
Description  
Single or multi-position thermomagnetic circuit breaker with  
lever actuation, DIN rail mounting, trip-free mechanism that  
cannot be influenced, various characteristic curves, all-pole  
tripping.  
100  
10  
The circuit breakers meet the requirements of circuit breaker  
standard EN 60934 (IEC 60934): S-type, TM.  
1
Typical areas of application are telecommunications  
systems, power supply units, industrial switchgear and  
control systems, and rail vehicles.  
The ideal characteristic curve shown here illustrates the  
curve of the thermomagnetic trigger characteristic. The time-  
delayed tripping protects the thermal part of the  
characteristic curve against overload. The magnetic part of  
the circuit breaker responds without delay to high overload  
and short-circuit currents and trips within a few milliseconds.  
0,1  
0,01  
1
2
4
6 810  
20  
Multiples of the nominal current  
Figure 1  
Ideal characteristic curve  
Thermal tripping range  
Magnetic tripping range  
Make sure you always use the latest documentation.  
It can be downloaded at www.phoenixcontact.net/catalog.  
This data sheet is valid for all products listed on the following page:  
TMC  
2
Ordering data  
Thermomagnetic circuit breaker  
Description  
Type  
TMC... (see order key)  
Order No.  
Pcs./Pkt.  
6
Thermomagnetic circuit breaker,  
with universal foot for mounting on  
3or 4  
Accessories  
Description  
Type  
EB 80-12  
Order No.  
3009338  
Pcs./Pkt.  
1
Insertion bridge, insulated, 80-pos.  
(I : 50 A)  
max  
(For central supply I : 80 A)  
N
Zack marker strip, 10-section, for labeling the center of the terminal block  
ZB 6  
See CLIPLINE catalog  
UniCard sheets, for labeling terminal blocks using a Zack marker strip  
groove, 96-section, can be labeled with BLUEMARK and CMS-P1-PLOTTER,  
color: white  
UC-TM 5  
0818108  
10  
Screwdriver  
SZS 0,6X3,5  
1205053  
10  
2.1  
Type  
Order key  
Main  
Characteristic  
curves  
Auxiliary  
contact versions  
Nominal  
current  
current paths  
TMC  
1 Single-pos.  
2 Two-pos.  
3 Three-pos.  
F1Thermal 1.05 x I ... 1.4 x I ,  
100 Single-pos.: 1 N/O contact  
200 Single-pos.: 1 N/C contact  
0.2 A  
0.3 A  
0.4 A  
0.5 A  
0.6 A  
0.8 A  
1 A  
2.5 A  
3 A  
4 A  
5 A  
6 A  
N
N
magnetic 2 x I ... 4 x I DC (fast-blow),  
N
N
only for DC applications  
M1Thermal 1.05 - 1.4 I ,  
120 Two-pos.: 1 N/O contact, 1 N/C  
contact  
N
122 Three-pos.: 1 N/O contact, 2 N/C  
magnetic  
6 x I ... 12 x I AC,  
N
N
contacts  
7.8 x I ... 15.6 x I DC  
8 A  
N
N
(medium-blow)  
10 A  
12 A  
15A  
16A  
1.2 A  
2A  
Ordering example  
TMC with 1-pos. main current path, one N/O contact,  
medium-blow characteristic curve, and a nominal current of  
2 A: TMC 1 M1 100 2A  
3
Technical data  
Technical data  
Nominal voltage  
250 V AC (65 V DC),  
3 433 V AC (50/60 Hz)  
Nominal current range  
Auxiliary circuit  
0.2 A ... 16 A, see order key  
240 V AC (65 V DC), 1 A  
Service life  
10,000 cycles with 1 x I , inductive  
N
Ambient temperature  
Insulation coordination (IEC 60664)  
Dielectric strength  
-30°C ... +60°C (T 60)  
2.5 kV/2, increased insulation in the actuation area  
Actuation area  
3000 V AC test voltage  
3000 V AC test voltage  
1500 V AC test voltage  
> 100 M(500 V DC)  
Main to auxiliary circuit  
Position to position  
Insulation resistance  
100695_en_03  
PHOENIX CONTACT  
2
TMC  
Technical data  
Switching capacity I  
cn  
TMC...0,2 A ... TMC...5 A  
TMC...6 A ... TMC...16 A  
Characteristic curve F1 and M1  
400 A  
800 A  
2500 A (at 32 V DC)  
Switching capacity I (UL 1077)  
N
I = 0.2 A ... 16 A  
N
1 and 2-pos.  
3-pos.  
1 and 2-pos.  
277 V AC/5000 A  
480 V AC/5000 A  
65 V DC/2000 A  
Degree of protection (IEC 60529)  
Actuation area  
Connection area  
IP30  
IP20  
Vibration resistance  
Characteristic curve F1  
Characteristic curve M1  
3g (57 Hz ... 500 Hz), ±0.23 mm (10 Hz ... 57 Hz)  
53g (57 Hz ... 500 Hz), ±0.38 mm (10 Hz ... 57 Hz)  
Test according to IEC 60068-2-6, Test Fc, 10 frequency cycles/axis  
Shock resistance  
Characteristic curve F1  
Characteristic curve M1  
25g (11 ms), shock direction 1, 2, 3, 4, 5; 10g (11 ms), shock direction 6  
25g (11 ms), shock direction 1, 2, 3, 4, 5; 20g (11 ms), shock direction 6  
Test according to IEC 60068-2-27, Test Ea  
Corrosion resistance  
Humidity test  
Weight  
96 hours in 5% salt fog  
Test according to IE 60068-2-11, Text Ka  
240 hours in 95% relative humidity  
Test according to IE 60068-2-78, Text Cab  
60 g per position, approximately  
Technical data according to IEC/DIN VDE  
Impulse voltage withstand level  
Pollution degree  
4 kV  
3
2
Auxiliary contact: maximum load current  
Maximum cross-section with insertion bridge (solid and stranded)  
Surge voltage category  
1 A for 2.5 mm  
1.5 mm  
III  
I
2
Insulation material group  
Connection capacity  
Connection capacity  
Solid  
Main contact  
Auxiliary contact  
2
2
2
2
2
2
0.2 mm ... 6 mm  
0.2 mm ... 2.5 mm  
2
2
Stranded  
0.2 mm ... 4 mm  
0.2 mm ... 1.5 mm  
Connection capacity (stranded with ferrule)  
Without plastic sleeve  
With plastic sleeve  
2
2
2
2
2
0.25 mm ... 4 mm  
2
0.25 mm ... 2.5 mm  
2
2
0.25 mm ... 2.5 mm  
0.25 mm ... 1.5 mm  
Two conductors with the same cross-section  
Solid and stranded  
Stranded with ferrule without plastic sleeve  
Stranded with TWIN ferrule with plastic sleeve  
2
2
2
2
0.2 mm ... 1 mm  
0.2 mm ... 0.75 mm  
2
2
2
2
0.2 mm ... 1 mm  
0.2 mm ... 0.5 mm  
2
2
2
2
0.5 mm ... 2.5 mm  
0.5 mm ... 0.75 mm  
100695_en_03  
PHOENIX CONTACT  
3
TMC  
Connection capacity (continued)  
Stripping length  
Main contact  
Auxiliary contact  
12 mm  
12 mm  
Internal cylindrical gauge (IEC 60947-1)  
Screw thread  
A 3  
M3  
A 1  
M3  
Tightening torque  
0.6 Nm ... 0.8 Nm  
0.6 Nm ... 0.8 Nm  
General data  
Width x length  
12.5 mm x 83.5 mm  
Height  
On NS 35/7.5... DIN rail  
On NS 35/15... DIN rail  
On NS 32... DIN rail  
Insulation material  
96 mm  
103.5 mm  
100.5 mm  
PA-F  
Inflammability class according to UL 94  
Degree of protection (IEC 60529)  
Actuation area  
V0  
IP30  
IP20  
Connection area  
Approvals  
Test center  
GL, VDE (EN 60934)  
UL, CSA  
Nominal voltage  
Nominal current range  
0.1 A ... 32 A  
3 433 V AC, 250 V AC, 65 V DC  
277 V AC, 277/480 V AC,  
3 480 V AC, 65 V DC  
0.1 A ... 32 A  
...200...  
...100...  
OFF position  
Mains  
ON position  
Mains  
Actuation area  
(increased insulation)  
SafetyN/C  
contact  
Mains  
Mains  
Safety N/O  
contact  
Installation area  
Installation diagram  
Figure 3  
Figure 2  
Circuit diagrams  
100695_en_03  
PHOENIX CONTACT  
4
TMC  
Groove for  
marking labels  
Main contact  
Connection terminal block  
M3, maximum of 6 mm²  
(solid), 0.5 Nm tightening  
torque  
Auxiliary contact  
Connection terminal block M3,  
maximum of 1.5 mm² (solid),  
0.5 Nm tightening torque  
Figure 4  
Dimensional drawing (dimensions in mm)  
100695_en_03  
PHOENIX CONTACT  
5
TMC  
4
Backup fuse  
5
Trigger characteristics  
The thermomagnetic circuit breaker is available in  
18 nominal current levels and in single and multi-pos.  
versions.  
NOTE: Use a backup fuse in combination with the  
circuit breaker if the maximum switching current  
can be exceeded in the event of an error.  
The version with the "medium-blow (M1)" trigger  
The table lists the maximum switching current, the relevant  
internal resistance, and the resulting backup fuse.  
characteristic is suitable for AC and DC applications. The  
"fast-blow (F1)" characteristic version is suitable for  
DC applications.  
Nominal  
current  
NH  
backup  
fuse  
Internal resistance Switching  
capacity  
The characteristic curves (see page 7) depend on the  
ambient temperatures. To avoid early or late disconnection,  
the circuit breaker nominal current must be multiplied by a  
factor.  
F1 (fast- M1  
according  
blow)  
(medium-  
blow)  
to  
for DC  
EN 60934  
for DC/AC  
0.2 A  
0.3 A  
0.4 A  
0.5 A  
0.6 A  
0.8 A  
1 A  
1.5 A  
2 A  
2.5 A  
3 A  
4 A  
5 A  
6 A  
8 A  
10 A  
12 A  
16 A  
Any  
Any  
Any  
Any  
Any  
39.3   
17.5   
9.2   
6.8   
4.2   
26.1   
11.6   
6.6   
4.1   
3   
1.65   
1.10   
0.47   
0.28   
0.183   
0.124   
0.077   
0.063   
0.045   
0.02   
0.02   
400 A  
400 A  
400 A  
400 A  
400 A  
400 A  
400 A  
400 A  
400 A  
400 A  
400 A  
400 A  
400 A  
800 A  
800 A  
800 A  
800 A  
800 A  
Ambient temperature  
Multiplication factor  
-30°C  
-20°C  
-10°C  
0°C  
10°C  
20°C  
30°C  
40°C  
50°C  
60°C  
0.76  
0.79  
0.83  
0.88  
0.93  
1
1.04  
1.11  
1.19  
1.29  
Any  
Any  
2.8   
1.6   
25 A  
25 A  
25 A  
25 A  
25 A  
25 A  
50 A  
50 A  
50 A  
50 A  
50 A  
0.78   
0.42   
0.26   
0.18   
0.12   
0.092   
0.054   
0.025   
0.022   
The characteristic curves (see page 7) are also valid for  
multi-position devices if all positions have an equal load. For  
multi-position devices and only 1-pos. overload, the thermal  
tripping limit changes for characteristic curves F1 and M1 to  
a maximum of 1.7 x IN.  
For DC, the magnetic operate values of the curves are  
around factor 1.3 higher.  
0.02 0.02   
0.02 0.02   
Tripping is supported even with high-energy current peaks  
< 0.003 s.  
NOTE: When mounting several circuit breakers  
in rows, observe the mutual warming effect.  
When the circuit breakers are loaded  
simultaneously, a mutual warming effect occurs,  
which has the same effect as an increase in  
ambient temperature.  
In this case, the nominal current can only be led to 80%.  
Alternatively, the load current can be increased by a  
multiplication factor and the circuit breaker dimensioned  
accordingly.  
100695_en_03  
PHOENIX CONTACT  
6
TMC  
5.1  
Medium-blow (M1): Nominal value 0.2 A ... 6 A  
Lower tripping limit: 1.05 x IN  
10000  
Lower tripping limit: 1.05 x IN  
Upper tripping limit: 1.4 x IN  
– 30°C  
+ 23°C  
10000  
1000  
100  
– 30°C  
+ 23°C  
1000  
+ 55°C  
100  
10  
1
10  
1
+ 50°C  
0,1  
DC  
0,1  
0,01  
0,01  
0,001  
AC  
Multiples of the  
nominal current  
0,8 1  
2
3
4
6
8 10 20 30 50 70 100  
Multiples of the  
nominal current  
0,001  
0,8 1  
2
3 4 6 8 10  
20 30 50 70 100  
5.2  
Medium-blow (M1): Nominal value 8 A ... 16 A  
Lower tripping limit: 1.05 x IN  
Upper tripping limit: 1.4 x IN  
10000  
– 30°C  
+ 23°C  
1000  
100  
+ 55°C  
10  
1
DC  
0,1  
AC  
0,01  
0,001  
Multiples of the  
nominal current  
6 8 10 20 30 50 70 100  
0,8 1  
2
3
4
5.3  
Fast-blow (F1): Nominal value 0.2 A ... 16 A  
Only for DC applications.  
PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany  
www.phoenixcontact.com  
100695_en_03  
7

相关型号:

0915302

Modular Terminal Block
PHOENIX

0915315

Modular Terminal Block
PHOENIX

0915328

Modular Terminal Block
PHOENIX

0915331

Modular Terminal Block
PHOENIX

0915344

Modular Terminal Block
PHOENIX

0915357

Modular Terminal Block
PHOENIX

0915360

Modular Terminal Block
PHOENIX

0915373

Modular Terminal Block
PHOENIX

0915409

Modular Terminal Block
PHOENIX

0915412

Modular Terminal Block
PHOENIX

0915425

Modular Terminal Block
PHOENIX

0915438

Modular Terminal Block
PHOENIX