Mini-Com TX5e UTP Jack Modules
S P E C I F I C A T I O N S H E E T
TX5500™ UTP Copper
Cabling System
Mini-Com® TX5e™ UTP
Jack Modules
Jack module:
Shuttered jack
module:
Keyed jack
module:
s p e c i f i c a t i o n s
Category 5e/Class D, 8-position, UTP jack module shall terminate 4-pair, 22 – 26
AWG, 100 ohm unshielded twisted pair cable and shall not require use of a punchdown
tool. UTP jack modules shall use a forward motion termination method to optimize
performance by maintaining cable pair geometry while eliminating conductor untwist.
The termination cap shall be color-coded red to designate Category 5e performance
and shall include a universal label coded for T568A and T568B wiring schemes.
CJ5E88TGIW*
CJD5E88TGIW*
CJK5E88TG**
CJR5E88TG*
t e c h n i c a l i n f o r m a t i o n
Right angle
jack module:
TX5500™ UTP Copper Cable
Category 5e/Class
D channel
and component
performance:
Exceeds channel requirements of ANSI/TIA-568-C.2 Category 5e and ISO 11801
Class D standards at swept frequencies 1 to 100 MHz
Exceeds component requirements of ANSI/TIA-568-C.2 Category 5e and ISO
11801 Class D standards at swept frequencies 1 to 100 MHz
Plenum:
Riser:
LSZH (60332-1):
LSZH (60332-3):
CM:
PUP5504***
PUR5504***
PUL5504***
PUZ5504***
PUC5504***
FCC and
ANSI compliance:
Meets all applicable ANSI/TIA-968-A requirements; contacts plated with 50
microinches of gold for superior performance
Category 5e Performance SD UTP 28
IEC compliance:
RoHS compliance:
PoE compliance:
UL rated:
Meets IEC 60603-7
AWG Patch Cords (Dual Rated CM/LSZH)
Compliant
Feet:
UTP28CH^
Meters:
UTP28CH^^M
Meets requirements of IEEE 802.3af and IEEE 802.3at for PoE applications
UL 1863 approved
TX5e™ UTP Patch Cords
CM (foot lengths):
UTPCH^Y
CM (meter lengths):
LSZH (meter lengths):
Mini-Com® Angled Modular
Patch Panels
24-port, 1 RU:
48-port, 2 RU:
Mini-Com® Flat Modular
Patch Panels
UTPCH^^MY
UTPCHL^^MY
Conductor
Wire cap compatible with 22 – 26 AWG solid or stranded cable with conductor
insulation diameters of 0.060 in. max. and overall cable O.D. 0.200 in. to 0.330 in.
termination range:
k e y f e a t u r e s a n d b e n e f i t s
100% performance tested
CPPLA24WBLY
CPPLA48WBLY
Confidence that each jack module will deliver the critical electrical
performance requirements
Utilizes enhanced
Optimizes performance by eliminating conductor untwist and reduces
installation time and expense
24-port, 1 RU:
48-port, 2 RU:
CPPL24WBLY
CPPL48WBLY
Giga-TX™ Technology
For additional modular patch panels and punchdown
patch panels, visit www.panduit.com
Improved termination cap
Modular
Conductor retention slots simplify jack module termination
UTP jack modules snap in and out of all Mini-Com® Faceplates, Modular
Patch Panels and Surface Mount Boxes for easy moves, adds,
and changes
Tools and Accessories
Jack module
termination tool:
Wire snipping tool:
Wire stripping tool:
Clear dust cap:
Blockout device:
Phone icons:
EGJT or TGJT
CWST
CJAST
True strain relief
Controls cable bend radius for long-term installed performance
Marked with quality control number for future traceability
Individually serialized
MDC-C
PSL-DCJB-^^^
CIPIW-C+
CIDIW-C+
RJ45 interface
Industry standard interface provides a quick and easy plug and play
connection to RJ45 patch cords; backwards compatible
Data icons:
Identification
Can be clearly identified with optional labels and icons for port Identification
*To designate color other than IW (Off White),
replace IW suffix with WH (White), EI (Electric Ivory),
IG (International Gray), AW (Arctic White),
BL (Black), BU (Blue), RD (Red), YL (Yellow),
GR (Green), OR (Orange), VL (Violet), BR (Brown), GD
(Gold), LB (Light Blue), or PK (Pink).
Keyed version available
Color-specific keys with positive and negative keying features mechanically
and visually distinguish connections to prevent unintentional mating with
unlike keyed or non-keyed modular plugs, offering network design flexibility,
versatility, accommodating discrete networks for enhanced security
**To designate color, add suffix BL (Black),
BU (Blue), RD (Red), YL (Yellow), GR (Green),
or OR (Orange). Each color representing a
different keyed configuration.
Angle termination
version available
Side opening allows cable to be terminated to the right or left side of the
jack module; ideal for installations that have minimal depth that may not
allow standard bend radius practices to be accommodated
***To designate color, add suffix BU (Blue) or
WH (White). For additional cable colors, contact
customer service.
Termination tools
(optional)
EGJT termination tool ensures conductors are fully terminated by utilizing
a smooth forward motion without impact on critical internal components
for maximum reliability; TGJT termination tool ideal for high
volume installations
^For lengths 1 to 20 feet (one foot increments)
and 25, 30, 35, 40 feet, change the length designation in
the part number to the desired
length. For standard cable colors other than
Off White, add suffix BL (Black), BU (Blue),
RD (Red), YL (Yellow), GR (Green), OR (Orange),
or VL (Violet). For example, the part number for
a blue 15-foot patch cord is UTPCH15BUY.
Block out device
(optional)
Provides a simple and secure method to control access to data ports while
not in use
Shuttered version
(optional)
Integrated shuttered door keeps out dust and debris of unmated RJ45
jack modules
^^For lengths 1 to 10 meters (one meter increments) and
0.5, 1.5, 2.5, 15, 20, 25, 30, 35, 40 meters, change the
length designation in the part number to the desired
length. For standard cable colors other than Off White,
add suffix BL (Black), BU (Blue),
RD (Red), YL (Yellow), GR (Green), OR (Orange),
or VL (Violet). For example, the part number for a blue
15-meter patch cord is UTPCH15MBUY.
a p p l i c a t i o n s
Mini-Com® TX5e™ UTP Jack Modules are a component of the TX5500™ UTP Copper Cabling System. This
end-to-end system provides Gigabit Ethernet performance with usable bandwidth beyond 100 MHz. With
certified performance to the ANSI/TIA-568-C.2 Category 5e and ISO 11801 Class D standards, this system
will support the following applications:
^^^To designate color other than Red, add suffix
Black (BL), Blue (BU), Yellow (YL), Green (GR),
Orange (OR), Off White (IW) or International Gray
(IG) at the end of the part number. 10/package.
+To designate color other than IW (Off White),
replace IW with EI (Electric Ivory), IG (International Gray),
BL (Black), BU (Blue), RD (Red), YL (Yellow), GR (Green),
OR (Orange), or VL (Violet) in the part number. 100/
package.
• Ethernet 10BASE-T, 100BASE-T (Fast Ethernet), 1000BASE-T (Gigabit Ethernet)
• 155 Mb/s ATM, 622 Mb/s ATM
• Token ring 4/16
• Voice/data systems
• Voice over Internet Protocol (VoIP)
www.panduit.com
Contact customer service for bulk packaged
and/or keyed jack modules and patch cords.
®
™
Mini-Com TX5e UTP Jack Modules
t e s t r e s u l t s
Mechanical Test
Test Method
—
Measurement
Load (grams)
Typical Test Results
Normal Force
> 100
< 40
< 5
Vibration
IEC 512-6d
IEC 512-6c
IEC 512-9a
Circuit Resistance (mOhms)
Contact Disturbance (microseconds)
Circuit Resistance (mOhms)
Mating Force (N)
Shock
Durability
< 40
< 20
< 20
>20
Mating/Un-mating
IEC 512-13b
IEC 352
Un-mating Force (N)
Termination Cycles
Number of Cycles
Electrical Test
Test Method
IEC 512-2a
IEC 512-4a
IEC 512-3a
Measurement
Resistance (mOhms)
1000 V, 1 minute
Typical Test Results
Low Level Circuit Resistance
Dielectric Withstand Voltage
Insulation Resistance
< 20
Passed
> 500
Resistance (MOhms)
Environmental Test
Temperature Life
Test Method
IEC 512-9b
IEC 512-11c
IEC 512-11d
IEC 512-11a
IEC 512-11g
Measurement
Typical Test Results
Circuit Resistance (mOhms)
Circuit Resistance (mOhms)
Circuit Resistance (mOhms)
Circuit Resistance (mOhms)
Circuit Resistance (mOhms)
< 40
< 40
< 40
< 40
< 40
Humidity
Thermal Shock
Climatic Sequence
Flowing Mixed Gas Corrosion
0.71
(18.06)
0.62
(15.87)
Jack Module and
Standard Wire Cap
Jack Module and
Right Angle Wire Cap
1.50
(38.15)
Jack Module
Shuttered Jack Module
Right Angle Jack Module
Dimensions are in inches (Dimensions in parenthesis are metric)
WORLDWIDE SUBSIDIARIES AND SALES OFFICES
PANDUIT CANADA
Markham, Ontario
cs-cdn@panduit.com
PANDUIT EUROPE LTD.
PANDUIT SINGAPORE PTE. LTD.
Republic of Singapore
cs-ap@panduit.com
PANDUIT JAPAN
Tokyo, Japan
PANDUIT LATIN AMERICA
PANDUIT AUSTRALIA PTY. LTD.
London, UK
Guadalajara, Mexico
cs-la@panduit.com
Victoria, Australia
cs-emea@panduit.com
Phone: 800.777.3300 Phone: 44.20.8601.7200
cs-japan@panduit.com
cs-aus@panduit.com
Phone: 61.3.9794.9020
Phone: 65.6305.7575
Phone: 81.3.6863.6000 Phone: 52.33.3777.6000
For a copy of Panduit product warranties, log on to www.panduit.com/warranty
For more information
©2015 Panduit Corp.
ALL RIGHTS RESERVED.
Visit us at www.panduit.com
Contact Customer Service by email: cs@panduit.com
or by phone: 800.777.3300
COSP316--WW-ENG
Resplaces WW-COSP37
4/2015
相关型号:
©2020 ICPDF网 联系我们和版权申明