S P E C I F I C A T I O N S H E E T  
s p e c i f i c a t i o n s  
TX6 PLUS UTP  
Category 6/Class E, 8-position, UTP jack module shall  
terminate solid, 4-pair, 24 – 22 AWG, 100 ohm unshielded  
twisted pair cable and shall not require use of a punchdown  
tool. UTP jack modules shall use a forward motion termination  
method to optimize performance by maintaining cable pair  
geometry while eliminating conductor untwist. The termination  
cap shall be color-coded white to designate Category 6  
performance and shall include a universal label coded for  
T568A and T568B wiring schemes.  
Copper Cabling System  
Mini-Com ® TX6 PLUS  
UTP Jack Module  
Jack module:  
TX6000 UTP Copper Cable  
CJ688TPIW*  
Plenum:  
Riser:  
LSZH (60332-1):  
LSZH (60332-3):  
CM:  
PUP6004**  
PUR6004**  
PUL6004**  
PUZ6004**  
PUC6004**  
t e c h n i c a l i n f o r m a t i o n  
Category 6/Class E channel  
and component performance:  
Exceeds channel requirements of ANSI/TIA-568-C.2 Category 6  
and ISO 11801 Class E standards at swept frequencies  
1 to 250 MHz  
TX6 PLUS UTP Patch Cords  
CM (foot lengths): UTPSP^Y  
CM (meter lengths): UTPSP^^MY  
Exceeds component requirements of ANSI/TIA-568-C.2 Category 6  
and ISO 11801 Class E standards at swept frequencies  
1 to 250 MHz  
LSZH  
(meter lengths):  
UTPSPL^^MY  
FCC and ANSI compliance:  
PoE compliance:  
Meets ANSI/TIA-1096-A; contacts plated with 50 microinches of  
gold for superior performance  
Mini-Com ® Angled  
Modular Patch Panels  
Rated for 2500 cycles with IEEE 802.3af / 802.3at and proposed  
802.3bt type 3 and type 4  
24-port, 1 RU:  
48-port, 2 RU:  
CPPLA24WBLY  
CPPLA48WBLY  
IEC compliance:  
RoHS compliance:  
UL rated:  
Meets IEC 60603-7  
Mini-Com ® Flat Modular  
Patch Panels  
Compliant  
UL 1863 approved  
24-port, 1 RU:  
48-port, 2 RU:  
CPPL24WBLY  
CPPL48WBLY  
Conductor  
termination range:  
Wire cap compatible with 24 – 22 AWG solid cable with conductor  
insulation diameters of 0.035 in. to 0.048 in. and overall cable O.D.  
0.200 in. to 0.330 in.  
For additional modular and punchdown  
patch panels, visit www.panduit.com.  
Tools and Accessories  
Jack module  
k e y f e a t u r e s a n d b e n e f i t s  
100% performance tested  
Confidence that each jack module will deliver the critical  
electrical performance requirements  
termination tool:  
CGJT  
Wire snipping tool: CWST  
Wire snipping tool: CJAST  
Utilizes enhanced  
Giga-TX™ Technology  
Optimizes performance by eliminating conductor untwist and  
reduces installation time and expense  
Clear dust cap:  
MDC-C  
Block out device: PSL-DCJB-^^^  
Improved termination cap  
Modular  
Conductor retention slots simplify jack module termination  
Phone icons:  
Data icons:  
CIPIW-C+  
CIDIW-C+  
UTP jack modules snap in and out of all Mini-Com® Faceplates,  
Modular Patch Panels and Surface Mount Boxes for easy moves,  
adds and changes  
*To designate color other than IW (Off White), replace  
IW suffix with EI (Electric Ivory), IG (International Gray),  
WH (White), AW (Arctic White), BL (Black), BU (Blue),  
RD (Red), YL (Yellow), GR (Green), OR (Orange),  
BR (Brown), GD (Gold), LB (Light Blue), PK (Pink), or  
VL (Violet).  
True strain relief  
Controls cable bend radius for long term installed performance  
Individually serialized  
RJ45 interface  
Marked with quality control number for future traceability  
Industry standard interface provides a quick and easy plug and  
play connection to RJ45 patch cords; backwards compatible  
**To designate color, add suffix BU (Blue) or WH  
(White). For additional cable colors, contact customer  
service.  
^For lengths 1 to 20 feet (one foot increments) and 25,  
30, 35, 40 feet, change the length designation in the  
part number to the desired length. For standard cable  
colors other than Off White, add suffix BL (Black),  
BU (Blue), RD (Red), YL (Yellow), GR (Green), OR  
(Orange) or VL (Violet). For example, the part number  
for a blue 15-foot patch cord is UTPSP15BUY.  
Identification  
Can be clearly identified with optional labels and icons for  
port identification  
Termination tools (optional)  
CGJT termination tool ensures conductors are fully terminated  
by utilizing a smooth forward motion without impact on critical  
internal components for maximum reliability  
Block out device (optional)  
Provides a simple and secure method to control access to data  
ports while not in use  
^^For lengths 1 to 10 meters (one meter increments)  
and 0.5, 1.5, 2.5, 15, 20, meters, change the length  
designation in the part number to the desired length.  
For standard cable colors other than Off White, add  
suffix BL (Black), BU (Blue), RD (Red), YL (Yellow),  
GR (Green), OR (Orange) or VL (Violet). For example,  
the part number for a blue 15-meter patch cord  
is UTPSP15MBUY.  
a p p l i c a t i o n s  
Mini-Com® TX6PLUS UTP Jack Modules are a  
component of the TX6PLUS UTP Copper Cabling  
System. This end-to-end system is interoperable and  
backwards compatible, providing design flexibility to  
protect network investments well into the future. With  
certified performance to the ANSI/TIA-568-C.2  
Category 6 and ISO 11801 Class E standards, this  
system is ideal for today's high performance  
Class E standards, these systems will support the  
following applications:  
• Ethernet 10BASE-T, 100BASE-T (Fast  
Ethernet), 1000BASE-T (Gigabit Ethernet)  
• 155 Mb/s ATM, 622 Mb/s ATM, 1.2 Gb/s ATM  
Token Ring 4/16  
• Digital video and broadband/baseband  
analog video  
^^^To designate color other than Red, add suffix BL  
(Black), BU (Blue), YL (Yellow), GR (Green), OR  
(Orange), IW (Off White) or IG (International Gray) at  
end of the part number. 10/package.  
+To designate color other than IW (Off White), replace  
IW with EI (Electric Ivory), IG (International Gray), BL  
(Black), BU (Blue), RD (Red), YL (Yellow), GR (Green),  
OR (Orange) or VL (Violet) in the part number.  
100/package.  
workstation applications. With certified performance  
to the ANSI/TIA-568-C.2 Category 6 and ISO 11801  
• Voice over Internet Protocol (VoIP)  
Contact customer service for bulk packaged jack  
modules and patch cords.  
www.panduit.com  
®
Mini-Com TX6 PLUS UTP Jack Module  
T e s t R e s u l t s  
Typical Test Results (dB)  
Performance Test  
Test Method  
20 MHz  
> 68.0  
> 64.0  
> 57.1  
> 54.1  
< 0.10  
> 30  
100 MHz  
> 54.0  
> 50.0  
> 43.0  
> 40.1  
< 0.21  
> 24.0  
200 MHz  
> 48.0  
> 44.0  
> 37.1  
> 34.1  
< 0.28  
> 18.0  
250 MHz  
> 46.0  
> 42.0  
> 35.1  
> 32.2  
< 0.32  
> 16.0  
NEXT  
PS NEXT  
NEXT  
Category 6  
ANSI/TIA-568-C.2  
Standard  
PS NEXT  
Attenuation  
Return Loss  
Consult technical support for cable brand specific channel test results.  
Mechanical Test  
Normal Force  
Test Method  
IEC 512-6d  
IEC 512-9a  
IEC 512-13b  
Measurement  
Typical Test Results  
Load (grams)  
>100  
< 40  
< 40  
< 20  
< 20  
Vibration  
Circuit Resistance (mOhms)  
Circuit Resistance (mOhms)  
Mating Force (N)  
Durability  
Mating/Unmating  
Un-mating Force (N)  
Electrical Test  
Test Method  
IEC 512-2a  
IEC 512-4a  
IEC 512-3a  
Measurement  
Resistance (mOhms)  
1000 V, 1 minute  
Typical Test Results  
Low Level Circuit Resistance  
Dielectric Withstand Voltage  
Insulation Resistance  
< 40  
Passed  
> 500  
Resistance (MOhms)  
Environmental  
Temperature Life  
Test Method  
IEC 512-9b  
IEC 512-11c  
IEC 512-11d  
IEC 512-11a  
IEC 512-11g  
Measurement  
Typical Test Results  
Circuit Resistance (mOhms)  
Circuit Resistance (mOhms)  
Circuit Resistance (mOhms)  
Circuit Resistance (mOhms)  
Circuit Resistance (mOhms)  
< 40  
< 40  
< 40  
< 40  
< 40  
Humidity  
Thermal Shock  
Climatic Sequence  
Flowing Mixed Gas Corrosion  
0.71  
[18.08]  
Twist  
Preservation Cap  
0.63  
1.43  
[36.37]  
[15.88]  
Module Housing  
Dimensions are in inches. [Dimensions in brackets are metric].  
WORLDWIDE SUBSIDIARIES AND SALES OFFICES  
PANDUIT CANADA  
Markham, Ontario  
cs-cdn@panduit.com  
PANDUIT EUROPE LTD.  
PANDUIT SINGAPORE PTE. LTD.  
Republic of Singapore  
cs-ap@panduit.com  
PANDUIT JAPAN  
Tokyo, Japan  
PANDUIT LATIN AMERICA  
PANDUIT AUSTRALIA PTY. LTD.  
Victoria, Australia  
London, UK  
Guadalajara, Mexico  
cs-la@panduit.com  
cs-emea@panduit.com  
Phone: 800.777.3300 Phone: 44.20.8601.7200  
cs-japan@panduit.com  
cs-aus@panduit.com  
Phone: 65.6305.7575  
Phone: 81.3.6863.6000 Phone: 52.33.3777.6000  
Phone: 61.3.9794.9020  
For a copy of Panduit product warranties, log on to www.panduit.com/warranty  
For more information  
©2015 Panduit Corp.  
Visit us at www.panduit.com  
Contact Customer Service by email: cs@panduit.com  
or by phone: 800.777.3300 and reference COSP235  
ALL RIGHTS RESERVED.  
COSP235-WW-ENG  
5/2016  

相关型号:

UTPSPMY

Mini-Com® TX6™ PLUS UTP Jack Module
PANDUIT

UTPSPY

Mini-Com® TX6™ PLUS UTP Jack Module
PANDUIT

UTR01

RECTIFIERS
MICROSEMI

UTR01-PBF

Rectifier Diode
DIGITRON

UTR01HR

Rectifier Diode
DIGITRON

UTR02

RECTIFIERS
MICROSEMI

UTR02E3

Rectifier Diode
MICROSEMI

UTR02HR

Rectifier Diode
DIGITRON

UTR1

(589.03 k)
ETC

UTR10

RECTIFIERS
MICROSEMI
ETC

UTR10E3

Rectifier Diode, Avalanche, 1 Element, 0.5A, 600V V(RRM), Silicon, ROHS COMPLIANT, HERMETIC SEALED, MINIATURE, GLASS, A PACKAGE-2
MICROSEMI