Mini-Com TX6 PLUS UTP Jack Module
S P E C I F I C A T I O N S H E E T
s p e c i f i c a t i o n s
TX6 ™ PLUS UTP
Category 6/Class E, 8-position, UTP jack module shall
terminate solid, 4-pair, 24 – 22 AWG, 100 ohm unshielded
twisted pair cable and shall not require use of a punchdown
tool. UTP jack modules shall use a forward motion termination
method to optimize performance by maintaining cable pair
geometry while eliminating conductor untwist. The termination
cap shall be color-coded white to designate Category 6
performance and shall include a universal label coded for
T568A and T568B wiring schemes.
Copper Cabling System
Mini-Com ® TX6 ™ PLUS
UTP Jack Module
Jack module:
TX6000 ™ UTP Copper Cable
CJ688TPIW*
Plenum:
Riser:
LSZH (60332-1):
LSZH (60332-3):
CM:
PUP6004**
PUR6004**
PUL6004**
PUZ6004**
PUC6004**
t e c h n i c a l i n f o r m a t i o n
Category 6/Class E channel
and component performance:
Exceeds channel requirements of ANSI/TIA-568-C.2 Category 6
and ISO 11801 Class E standards at swept frequencies
1 to 250 MHz
TX6 ™ PLUS UTP Patch Cords
CM (foot lengths): UTPSP^Y
CM (meter lengths): UTPSP^^MY
Exceeds component requirements of ANSI/TIA-568-C.2 Category 6
and ISO 11801 Class E standards at swept frequencies
1 to 250 MHz
LSZH
(meter lengths):
UTPSPL^^MY
FCC and ANSI compliance:
PoE compliance:
Meets ANSI/TIA-1096-A; contacts plated with 50 microinches of
gold for superior performance
Mini-Com ® Angled
Modular Patch Panels
Rated for 2500 cycles with IEEE 802.3af / 802.3at and proposed
802.3bt type 3 and type 4
24-port, 1 RU:
48-port, 2 RU:
CPPLA24WBLY
CPPLA48WBLY
IEC compliance:
RoHS compliance:
UL rated:
Meets IEC 60603-7
Mini-Com ® Flat Modular
Patch Panels
Compliant
UL 1863 approved
24-port, 1 RU:
48-port, 2 RU:
CPPL24WBLY
CPPL48WBLY
Conductor
termination range:
Wire cap compatible with 24 – 22 AWG solid cable with conductor
insulation diameters of 0.035 in. to 0.048 in. and overall cable O.D.
0.200 in. to 0.330 in.
For additional modular and punchdown
patch panels, visit www.panduit.com.
Tools and Accessories
Jack module
k e y f e a t u r e s a n d b e n e f i t s
100% performance tested
Confidence that each jack module will deliver the critical
electrical performance requirements
termination tool:
CGJT
Wire snipping tool: CWST
Wire snipping tool: CJAST
Utilizes enhanced
Giga-TX™ Technology
Optimizes performance by eliminating conductor untwist and
reduces installation time and expense
Clear dust cap:
MDC-C
Block out device: PSL-DCJB-^^^
Improved termination cap
Modular
Conductor retention slots simplify jack module termination
Phone icons:
Data icons:
CIPIW-C+
CIDIW-C+
UTP jack modules snap in and out of all Mini-Com® Faceplates,
Modular Patch Panels and Surface Mount Boxes for easy moves,
adds and changes
*To designate color other than IW (Off White), replace
IW suffix with EI (Electric Ivory), IG (International Gray),
WH (White), AW (Arctic White), BL (Black), BU (Blue),
RD (Red), YL (Yellow), GR (Green), OR (Orange),
BR (Brown), GD (Gold), LB (Light Blue), PK (Pink), or
VL (Violet).
True strain relief
Controls cable bend radius for long term installed performance
Individually serialized
RJ45 interface
Marked with quality control number for future traceability
Industry standard interface provides a quick and easy plug and
play connection to RJ45 patch cords; backwards compatible
**To designate color, add suffix BU (Blue) or WH
(White). For additional cable colors, contact customer
service.
^For lengths 1 to 20 feet (one foot increments) and 25,
30, 35, 40 feet, change the length designation in the
part number to the desired length. For standard cable
colors other than Off White, add suffix BL (Black),
BU (Blue), RD (Red), YL (Yellow), GR (Green), OR
(Orange) or VL (Violet). For example, the part number
for a blue 15-foot patch cord is UTPSP15BUY.
Identification
Can be clearly identified with optional labels and icons for
port identification
Termination tools (optional)
CGJT termination tool ensures conductors are fully terminated
by utilizing a smooth forward motion without impact on critical
internal components for maximum reliability
Block out device (optional)
Provides a simple and secure method to control access to data
ports while not in use
^^For lengths 1 to 10 meters (one meter increments)
and 0.5, 1.5, 2.5, 15, 20, meters, change the length
designation in the part number to the desired length.
For standard cable colors other than Off White, add
suffix BL (Black), BU (Blue), RD (Red), YL (Yellow),
GR (Green), OR (Orange) or VL (Violet). For example,
the part number for a blue 15-meter patch cord
is UTPSP15MBUY.
a p p l i c a t i o n s
Mini-Com® TX6™ PLUS UTP Jack Modules are a
component of the TX6™ PLUS UTP Copper Cabling
System. This end-to-end system is interoperable and
backwards compatible, providing design flexibility to
protect network investments well into the future. With
certified performance to the ANSI/TIA-568-C.2
Category 6 and ISO 11801 Class E standards, this
system is ideal for today's high performance
Class E standards, these systems will support the
following applications:
• Ethernet 10BASE-T, 100BASE-T (Fast
Ethernet), 1000BASE-T (Gigabit Ethernet)
• 155 Mb/s ATM, 622 Mb/s ATM, 1.2 Gb/s ATM
• Token Ring 4/16
• Digital video and broadband/baseband
analog video
^^^To designate color other than Red, add suffix BL
(Black), BU (Blue), YL (Yellow), GR (Green), OR
(Orange), IW (Off White) or IG (International Gray) at
end of the part number. 10/package.
+To designate color other than IW (Off White), replace
IW with EI (Electric Ivory), IG (International Gray), BL
(Black), BU (Blue), RD (Red), YL (Yellow), GR (Green),
OR (Orange) or VL (Violet) in the part number.
100/package.
workstation applications. With certified performance
to the ANSI/TIA-568-C.2 Category 6 and ISO 11801
• Voice over Internet Protocol (VoIP)
Contact customer service for bulk packaged jack
modules and patch cords.
www.panduit.com
®
™
Mini-Com TX6 PLUS UTP Jack Module
T e s t R e s u l t s
Typical Test Results (dB)
Performance Test
Test Method
20 MHz
> 68.0
> 64.0
> 57.1
> 54.1
< 0.10
> 30
100 MHz
> 54.0
> 50.0
> 43.0
> 40.1
< 0.21
> 24.0
200 MHz
> 48.0
> 44.0
> 37.1
> 34.1
< 0.28
> 18.0
250 MHz
> 46.0
> 42.0
> 35.1
> 32.2
< 0.32
> 16.0
NEXT
PS NEXT
NEXT
Category 6
ANSI/TIA-568-C.2
Standard
PS NEXT
Attenuation
Return Loss
Consult technical support for cable brand specific channel test results.
Mechanical Test
Normal Force
Test Method
—
IEC 512-6d
IEC 512-9a
IEC 512-13b
Measurement
Typical Test Results
Load (grams)
>100
< 40
< 40
< 20
< 20
Vibration
Circuit Resistance (mOhms)
Circuit Resistance (mOhms)
Mating Force (N)
Durability
Mating/Unmating
Un-mating Force (N)
Electrical Test
Test Method
IEC 512-2a
IEC 512-4a
IEC 512-3a
Measurement
Resistance (mOhms)
1000 V, 1 minute
Typical Test Results
Low Level Circuit Resistance
Dielectric Withstand Voltage
Insulation Resistance
< 40
Passed
> 500
Resistance (MOhms)
Environmental
Temperature Life
Test Method
IEC 512-9b
IEC 512-11c
IEC 512-11d
IEC 512-11a
IEC 512-11g
Measurement
Typical Test Results
Circuit Resistance (mOhms)
Circuit Resistance (mOhms)
Circuit Resistance (mOhms)
Circuit Resistance (mOhms)
Circuit Resistance (mOhms)
< 40
< 40
< 40
< 40
< 40
Humidity
Thermal Shock
Climatic Sequence
Flowing Mixed Gas Corrosion
0.71
[18.08]
Twist
Preservation Cap
0.63
1.43
[36.37]
[15.88]
Module Housing
Dimensions are in inches. [Dimensions in brackets are metric].
WORLDWIDE SUBSIDIARIES AND SALES OFFICES
PANDUIT CANADA
Markham, Ontario
cs-cdn@panduit.com
PANDUIT EUROPE LTD.
PANDUIT SINGAPORE PTE. LTD.
Republic of Singapore
cs-ap@panduit.com
PANDUIT JAPAN
Tokyo, Japan
PANDUIT LATIN AMERICA
PANDUIT AUSTRALIA PTY. LTD.
Victoria, Australia
London, UK
Guadalajara, Mexico
cs-la@panduit.com
cs-emea@panduit.com
Phone: 800.777.3300 Phone: 44.20.8601.7200
cs-japan@panduit.com
cs-aus@panduit.com
Phone: 65.6305.7575
Phone: 81.3.6863.6000 Phone: 52.33.3777.6000
Phone: 61.3.9794.9020
For a copy of Panduit product warranties, log on to www.panduit.com/warranty
For more information
©2015 Panduit Corp.
Visit us at www.panduit.com
Contact Customer Service by email: cs@panduit.com
or by phone: 800.777.3300 and reference COSP235
ALL RIGHTS RESERVED.
COSP235-WW-ENG
5/2016
相关型号:
![](http://pdffile.icpdf.com/pdf2/p00244/img/page/UTR50E3_1477827_files/UTR50E3_1477827_1.jpg)
![](http://pdffile.icpdf.com/pdf2/p00244/img/page/UTR50E3_1477827_files/UTR50E3_1477827_2.jpg)
UTR10E3
Rectifier Diode, Avalanche, 1 Element, 0.5A, 600V V(RRM), Silicon, ROHS COMPLIANT, HERMETIC SEALED, MINIATURE, GLASS, A PACKAGE-2
MICROSEMI
©2020 ICPDF网 联系我们和版权申明