DSP1A-DC3V_12 [PANASONIC]
1a 8A, 1a1b/2a 5A small polarized power relays; 1A 8A , 1A1B / 2A 5A极化小功率继电器型号: | DSP1A-DC3V_12 |
厂家: | PANASONIC |
描述: | 1a 8A, 1a1b/2a 5A small polarized power relays |
文件: | 总6页 (文件大小:107K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
1a 8A, 1a1b/2a 5A
small polarized power
relays
DSP RELAYS
3. High sensitivity
Using the same type of high-
TYPICAL APPLICATIONS
1. Office and industrial electronic
devices
performance polar magnetic circuits as
DS relays, by matching the spring load
to the magnetic force of attraction,
greater sensitivity has been achieved.
The resultant pick up sensitivity of
about 190 mW makes possible direct
driving of transistors and chips.
4. High breakdown voltage
Breakdown voltage has been raised by
keeping the coil and contacts separate.
2. Terminal devices of information
processing equipment, such as
printer, data recorder.
3. Office equipment (copier, facsimile)
4. Measuring instruments
5. NC machines, temperature
controllers and programmable logic
controllers.
RoHS compliant
Between contact
Between contacts
and coil
3,000 Vrms for 1 min.
5,000 V surge
1,000 Vrms for 1 min.
1,500 V surge
breakdown voltage
breakdown voltage
Conforms with FCC Part 68
5. Latching types available
6. Wide variation
FEATURES
1. Compact with high contact rating
Even with small 10 mm .394 inch (H) x
11 mm .433 inch (W) x 20 mm .787
inch (L) (dimensions, high capacity
switching is provided: 1a, 8 A 250 V
AC; 2a and 1a1b, 5 A 250 V AC.
2. High switching capability
High contact pressure, low contact
bounce, and wiping operation improve
resistance to weld bonding. Resistant
against lamp load and dielectric
loading: 1a achieves maximum
switching capacity of 2,000 VA (8A 250
V AC).
Three types of contact arrangement
are offered: 1a, 2a, and 1a1b. In
addition, each is available in standard
and reversed polarity types.
7. Sealed construction allows
automatic washing.
8. Complies with safety standards
Complies with Japan Electrical
Appliance and Material Safety Law
requirements for operating 200 V
power supply circuits, and complies
with UL, CSA, and TÜV safety
standards.
9. Sockets are available.
ORDERING INFORMATION
DSP
Contact arrangement
1a: 1 Form A
1: 1 Form A 1 Form B
2a: 2 Form A
Operating function
Nil: Single side stable
L2: 2 coil latching
Nominal coil voltage
DC 3, 5, 6, 9, 12, 24 V
Polarity
Nil: Standard polarity
R: Reverse polarity
Contact material
• AgSnO2 type
F: 1 Form A 1 Form B
Nil: 1 Form A, 2 Form A
Notes: 1. Reverse polarity types available (add suffix-R)
2. Certified by UL, CSA and TÜV
ASCTB180E 201202-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
DSP
TYPES
Single side stable
Part No.
2 coil latching
Part No.
Contact
Nominal coil
voltage
arrangement
3V DC
5V DC
6V DC
9V DC
12V DC
24V DC
3V DC
5V DC
6V DC
9V DC
12V DC
24V DC
3V DC
5V DC
6V DC
9V DC
12V DC
24V DC
DSP1a-DC3V
DSP1a-DC5V
DSP1a-DC6V
DSP1a-DC9V
DSP1a-DC12V
DSP1a-DC24V
DSP1-DC3V-F
DSP1-DC5V-F
DSP1-DC6V-F
DSP1-DC9V-F
DSP1-DC12V-F
DSP1-DC24V-F
DSP2a-DC3V
DSP2a-DC5V
DSP2a-DC6V
DSP2a-DC9V
DSP2a-DC12V
DSP2a-DC24V
DSP1a-L2-DC3V
DSP1a-L2-DC5V
DSP1a-L2-DC6V
DSP1a-L2-DC9V
DSP1a-L2-DC12V
DSP1a-L2-DC24V
DSP1-L2-DC3V-F
DSP1-L2-DC5V-F
DSP1-L2-DC6V-F
DSP1-L2-DC9V-F
DSP1-L2-DC12V-F
DSP1-L2-DC24V-F
DSP2a-L2-DC3V
DSP2a-L2-DC5V
DSP2a-L2-DC6V
DSP2a-L2-DC9V
DSP2a-L2-DC12V
DSP2a-L2-DC24V
1 Form A
1 Form A
1 Form B
2 Form A
Standard packing: Carton: 50 pcs.; Case: 500 pcs.
Note: Reverse polarity type are manufactured by lot upon receipt of order. Self-clinching types are also available, please consult us.
* For sockets, see page 100.
RATING
1. Coil data
1) Single side stable
Nominal operating
current
[ 10%] (at 20°C 68°F)
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Coil resistance
[ 10%] (at 20°C 68°F)
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
3V DC
5V DC
6V DC
9V DC
12V DC
24V DC
100mA
60mA
30Ω
83Ω
120Ω
270Ω
480Ω
1,920Ω
80%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
50mA
130%V of
nominal voltage
300mW
33.3mA
25mA
12.5mA
2) 2 coil latching
Nominal operating
current
[ 10%] (at 20°C 68°F)
Coil resistance
[ 10%] (at 20°C 68°F)
Nominal operating
power
Nominal coil
voltage
Set voltage
(at 20°C 68°F)
Reset voltage
(at 20°C 68°F)
Max. applied voltage
(at 20°C 68°F)
Set coil
100mA
60mA
Reset coil
100mA
60mA
Set coil
30Ω
83Ω
120Ω
270Ω
480Ω
1,920Ω
Reset coil
30Ω
83Ω
120Ω
270Ω
480Ω
1,920Ω
Set coil
Reset coil
3V DC
5V DC
6V DC
9V DC
12V DC
24V DC
80%V or less of
nominal voltage
(Initial)
80%V or less of
nominal voltage
(Initial)
50mA
50mA
130%V of
nominal voltage
300mW
300mW
33.3mA
25mA
33.3mA
25mA
12.5mA
12.5mA
ASCTB180E 201202-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
DSP
2. Specifications
Characteristics
Item
Specifications
1 Form A 1 Form B
Arrangement
1 Form A
2 Form A
Contact
Contact resistance (Initial)
Contact material
Max. 30 mΩ (By voltage drop 6 V DC 1A)
Au-flashed AgSnO2 type
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
8 A 250 V AC, 5A 30V DC
2,000 VA, 150 W
5 A 250 V AC, 5 A 30 V DC
1,250 VA, 150 W
250 V AC, 125 V DC
5 A AC, DC
Rating
Max. switching current
8 A AC, 5 A DC
Nominal operating power
300 mW
Min. switching capacity (Reference value)*1
Insulation resistance (Initial)
Between open contacts
10m A 5 V DC
Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
1,000 Vrms for 1min. (Detection current: 10mA.)
Breakdown voltage
Between contact sets
(Initial)
2,000 Vrms (1 Form A 1 Form B, 2 Form A) (Detection current: 10mA.)
3,000 Vrms for 1min. (Detection current: 10mA.)
Between contact and coil
Electrical
characteristics
Surge breakdown
between contacts and coil
voltage*2
5,000 V
Temperature rise (coil) (at 65°C 149°F)
Operate time [Set time] (at 20°C 68°F)
Max. 55°C
Max. 40°C
Max. 55°C
Max. 10 ms [10 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Max. 5 ms [10 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
(without diode)
Release time [Reset time] (at 20°C 68°F)
Functional
Shock resistance
Min. 196 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 2 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 3.5 mm
Destructive
Mechanical
characteristics
Functional
Vibration resistance
Destructive
Mechanical
Electrical
Min. 5×107 (at 180 times/min.)
Expected life
Min. 105 (resistive load)
Ambient temperature:
–40°C to +60°C
–40°F to +140°F
Ambient temperature:
–40°C to +65°C
–40°F to +149°F
Ambient temperature:
–40°C to +60°C
–40°F to +140°F
Conditions for operation, transport and storage*3
(Not freezing and condensing at low temperature)
Conditions
Unit weight
250°C 482°F (10s), 300°C 572°F (5s), 350°C 662°F (3s)
Solder heating
(Soldering depth: 2/3 terminal pitch)
Max. operating speed
3 cps
Approx. 4.5 g .16 oz
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of 1.2×50µs according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
REFERENCE DATA
1. Max. switching capacity
2.-(1) Life curve (1 Form A 1 Form B)
2.-(2) Life curve (1 Form A 1 Form B)
10
AC resistive
load (1a)
100
100
30 V DC resistive
AC resistive
load
265 V·130 V AC cosϕ = 1
(1a1b,2a)
50
DC resistive
load (1a)
30 V DC L/R = 7 ms
1
10
265 V·130 V AC
cosϕ = 0.4
DC resistive load
(1a1b,2a)
10
0.1
0.5
1
5
10
0
1
2
3
4
5
6
7
10
100
1000
Switching capacity, A
Switching capacity, A
Contact voltage, V
3.-(1) Coil temperature rise (1 Form A)
Tested sample: DSP1a-DC12V, 5 pcs.
3.-(2) Coil temperature rise
(1 Form A 1 Form B)
3.-(3) Coil temperature rise (2 Form A)
Tested sample: DSP2a-DC12V, 5 pcs.
Tested sample: DSP1-DC12V, 5 pcs.
60
60
60
5A
8A
0A
50
40
30
20
10
0
50
50
5A
0A
0A
40
40
30
20
10
0
30
20
10
0
80
100
120
80
100
120
80
100
120
Coil applied voltage, %V
Coil applied voltage, %V
Coil applied voltage, %V
ASCTB180E 201202-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
DSP
4.-(1) Operate & release time
(without diode, 1 Form A)
Tested sample: DSP1a-DC12V, 5 pcs.
4.-(2) Operate & release time
(without diode, 1 Form A 1 Form B)
Tested sample: DSP1-DC12V, 5 pcs.
4.-(3) Operate & release time
(without diode, 2 Form A)
Tested sample: DSP2a-DC12V, 5 pcs.)
7
6
9
8
7
6
9
8
7
5
6
Operate time
Operate time
5
4
3
2
1
0
5
4
3
2
1
0
Operate time
Max.
4
3
x
Max.
x
Min.
Min.
Max.
x
Release time
Min.
2
Release time
Max.
x
Release time
Max.
x
Min.
Max.
x
Min.
1
0
Min.
80
100
110
80
100
120
80
100
120
Coil applied voltage, %V
Coil applied voltage, %V
Coil applied voltage, %V
4.-(4) Operate & release time
(with diode, 1 Form A)
Tested sample: DSP1a-DC12V, 5 pcs.
4.-(5) Operate & release time
(with diode, 1 Form A 1 Form B)
Tested sample: DSP1-DC12V, 5 pcs.
4.-(6) Operate & release time
(with diode, 2 Form A)
Tested sample: DSP2a-DC12V, 5 pcs.
9
8
7
6
9
8
7
6
9
8
7
6
Operate time
Operate time
5
Operate time
5
4
3
2
1
0
5
4
3
2
4
3
2
Max.
x
Max.
x
Max.
Max.
Min.
Max.
x
Min.
Max.
x
x
x
Min.
Min.
Min.
Min.
Release time
Release time
Release time
1
1
0
0
80
100
120
80
100
120
80
100 110
Coil applied voltage, %V
Coil applied voltage, %V
Coil applied voltage, %V
5.-(1) Change of pick-up and drop-out voltage
(1 Form A)
5.-(2) Change of pick-up and drop-out voltage
(1 Form A 1 Form B)
5.-(3) Change of pick-up and drop-out voltage
(2 Form A)
Tested sample: DSP1a-DC12V, 5 pcs.
Tested sample: DSP1-DC12V, 5 pcs.
Tested sample: DSP2a-DC12V, 5 pcs.
Drop-out
voltage
50
50
50
Drop-out
voltage
Pick-up voltage
Pick-up voltage
Pick-up voltage
–40 –20
0
–40 –20
0
–40 –20
0
20 40 60
Ambient
temperature, °C
80
20 40 60 80
Ambient
20 40 60 80
Ambient
temperature, °C
temperature, °C
Drop-out voltage
–50
–50
–50
6.-(1) Influence of adjacent mounting
(1 Form A)
6.-(2) Influence of adjacent mounting
(1 Form A 1 Form B)
6.-(3) Influence of adjacent mounting
(2 Form A)
Tested sample: DSP1a-DC12V, 5 pcs.
Tested sample: DSP1-DC12V, 5 pcs.
Tested sample: DSP2a-DC12V, 5 pcs.
15
15
10
Pick-up voltage
Pick-up voltage
Pick-up voltage
8
A
B
C
A
B
C
A
B
C
10
5
10
5
6
4
2
A, C
A, C
A, C
relays
relays
relays
are not
are not
are not
0
0
energized
energized
energized
15
10
5
15
10
5
A, C
A, C
A, C
–2
–4
Drop-out voltage
Drop-out voltage
Drop-out voltage
relays
are
relays
are
relays
are
energized
energized
energized
–6
–8
–10
0
5
10
0
5
10
1
2
3
4
5
6
Inter-relay distance ( ), mm
Inter-relay distance ( ), mm
Inter-relay distance ( ), mm
ASCTB180E 201202-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
DSP
The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/
DIMENSIONS (mm inch)
1. 1 Form A type
External dimensions
2 coil latching
PC board pattern (Bottom view)
CAD Data
Single side stable
Single side stable
2 coil latching
4-1.2 dia.
4-.047 dia.
6-1.2 dia.
6-.047 dia.
20.2
.795
20.2
.795
11.0
.433
2.54
.100
2.54
.100
10.0
10.5
10.0
.394
10.5
.413
.394
.413
2.54
.100
2.54
.100
0.3
Tolerance: 0.1 .004
1.0
1.0
.039
0.3
0.3
.012
3.5
3.5
.012
.039
.012
.138
0.8
.031
.138
1.0
.039
0.8
0.8
0.8
.031
.031
.031
Schematic (Bottom view)
1.21
1.21
7.2
.283
10.16
.400
7.2
.283
7.62
.300
Single side stable
2 coil latching
.048
2.54
.100
.048
7.62
.300
7.62
.300
7.62
16
–
15 16
.300
–
–
General tolerance: 0.3 .012
+
1
+
2
+
1
8
5
8
5
(Deenergized condition)
(Reset condition)
2. 1 Form A 1 Form B type
CAD Data
External dimensions
2 coil latching
PC board pattern (Bottom view)
Single side stable
Single side stable
2 coil latching
6-1.2 dia.
8-1.2 dia.
8-.047 dia.
20.2
.795
20.2
.795
11.0
.433
6-.047 dia.
2.54×3
2.54×4
.100×3 .100×4
2.54×3 2.54×3 2.54
.100×3 .100×3 .100
10.0
10.5
10.0
.394
10.5
.413
.394
.413
2.54×3
.100×3
2.54×3
.100×3
0.3
1.0
1.0
.039
0.3
0.3
.012
3.5
3.5
.012
.039
.012
Tolerance: 0.1 .004
2 coil latching
.138
0.8
.031
.138
1.0
.039
0.8
0.8
0.8
.031
.031
.031
1.21
1.21
Schematic (Bottom view)
Single side stable
7.2
.283
10.16
.400
7.2
.283
7.62
.300
.048
2.54
.100
.048
7.62
.300
7.62
.300
7.62
.300
16
–
15 16
9
12
9
12
–
–
General tolerance: 0.3 .012
+
1
+
2
+
1
8
5
8
5
(Deenergized condition)
(Reset condition)
3. 2 Form A type
CAD Data
External dimensions
2 coil latching
PC board pattern (Bottom view)
Single side stable
Single side stable
2 coil latching
6-1.2 dia.
8-1.2 dia.
8-.047 dia.
20.2
.795
20.2
.795
11.0
.433
6-.047 dia.
2.54×3
2.54×4
.100×3 .100×4
2.54×3 2.54×3 2.54
.100×3 .100×3 .100
10.0
10.5
10.0
.394
10.5
.413
.394
.413
2.54×3
.100×3
2.54×3
.100×3
0.3
1.0
1.0
.039
0.3
0.3
.012
3.5
3.5
.012
.039
.012
Tolerance: 0.1 .004
2 coil latching
.138
0.8
.031
.138
1.0
.039
0.8
0.8
0.8
.031
.031
.031
1.21
1.21
Schematic (Bottom view)
Single side stable
7.2
.283
10.16
.400
7.2
.283
7.62
.300
.048
2.54
.100
.048
7.62
.300
7.62
.300
7.62
.300
16
–
15 16
9
12
9
12
–
–
General tolerance: 0.3 .012
+
1
+
2
+
1
8
5
8
5
(Deenergized condition)
(Reset condition)
ASCTB180E 201202-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
DSP
SAFETY STANDARDS
UL/C-UL (Recognized)
Contact rating
CSA (Certified)
Contact rating
TÜV (Certified)
Rating
Item
File No.
E43028
File No.
File No.
B 02 10
13461 238
8A 250V AC
LR26550
etc.
8A 250V AC
1/6HP 125, 250V AC
5A 30V DC
8A 250V AC (cosφ=1.0)
5A 250V AC (cosφ=0.4)
5A 30V DC
1 Form A
1/6HP 125, 250V AC
5A 30V DC
E43028
E43028
5A 250V AC
LR26550
etc.
5A 250V AC
B 02 10
13461 238
5A 250V AC (cosφ=1.0)
3A 250V AC (cosφ=0.4)
5A 30V DC
1 Form A
1 Form B
1/6HP 125, 250V AC
5A 30V DC
1/6HP 125, 250V AC
5A 30V DC
5A 250V AC
1/10HP 125, 250V AC
5A 30V DC
LR26550
etc.
5A 250V AC
1/10HP 125, 250V AC
5A 30V DC
B 02 10
13461 238
5A 250V AC (cosφ=1.0)
3A 250V AC (cosφ=0.4)
5A 30V DC
2 Form A
* Remarks: The standard certified for may differ depending on where the product was manufactured.
NOTES
1. Soldering conditions
3. External magnetic field
5. When using, please be aware that
the a contact and b contact sides of 1
Form A and 1 Form B types may go on
simultaneously at operate time and
release time.
Please obey the following conditions
when soldering automatically.
1) Preheating: Within 120°C 248°F and
within 120 seconds
2) Soldering iron: 260°C 5°C
500°F 41°F and within 6 seconds
2. Cleaning
For automatic cleaning, the boiling
method is recommended. Avoid
ultrasonic cleaning which subjects the
relays to high frequency vibrations, which
may cause the contacts to stick.
It is recommended that a fluorinated
hydrocarbon or other alcoholic solvents
be used.
Since DY relays are highly sensitive
polarized relays, their characteristics will
be affected by a strong external magnetic
field. Avoid using the relay under that
condition.
4. Coil operating power
Pure DC current should be applied to the
coil. The wave form should be
rectangular. If it includes ripple, the ripple
factor should be less than 5%.
However, check it with the actual circuit
since the characteristics may be slightly
different.
For Cautions for Use.
ASCTB180E 201202-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
相关型号:
DSP1A-DC5V-R
Power/Signal Relay, 1 Form A, SPST, Momentary, 0.06A (Coil), 5VDC (Coil), 300mW (Coil), 5A (Contact), 125VDC (Contact), DC Input, Random, AC/DC Output, Through Hole-Straight Mount,
PANASONIC
DSP1A-DC6V-R
Electromechanical Relay, SPST, Latched, 7.8VDC (Coil), 5A (Contact), 125VDC (Contact), Random, AC/DC Output
PANASONIC
DSP1A-DC9V-R
Electromechanical Relay, SPST, Latched, 11.7VDC (Coil), 5A (Contact), 125VDC (Contact), Random, AC/DC Output
PANASONIC
©2020 ICPDF网 联系我们和版权申明