AHK11024 [PANASONIC]
Power/Signal Relay, SPDT, Momentary, 1300mW (Coil), 15A (Contact), 125VDC (Contact), AC Input, AC/DC Output, Socket Mount, CADMIUM FREE AND ROHS COMPLIANT;型号: | AHK11024 |
厂家: | PANASONIC |
描述: | Power/Signal Relay, SPDT, Momentary, 1300mW (Coil), 15A (Contact), 125VDC (Contact), AC Input, AC/DC Output, Socket Mount, CADMIUM FREE AND ROHS COMPLIANT 光电二极管 继电器 |
文件: | 总8页 (文件大小:167K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
COMPACT AND
HIGH CAPACITY
GENERAL PURPOSE
POWER RELAYS
HK RELAYS (AHK)
FEATURES
TYPICAL APPLICATIONS
1. Economical prices achieved
To assist rationalization, prices reduced
to about half the price of previous
products.
Control panels
Power supply units
Molding machines
Machine tools
2. Compact with high-capacity
Enables high-capacity control:
Welding equipment
Agricultural equipment
Office equipment
Vending machines
Communications equipment
Amusement machines, etc.
15 A for 1 Form C, 10 A for 2 Form C
3.Types for wide range of applications
Range includes relays with operation
indicators, built-in diodes to absorb relay
coil surge, and built-in CR circuits.
4. Cadmium-free contacts
5. UL/C-UL and TÜV approved parts
available. Compliance with Japanese
Electrical Appliance and Material
Control Law is standard.
Compliance with RoHS Directive
ORDERING INFORMATION
AHK
HK relays
Contact arrangement
1: 1 Form C
2: 2 Form C
Terminal arrangement
1: AC plug-in type
2: DC plug-in type
Type classification
0: Standard
1: With LED indication
2: With diode
3: With LED indication, diode
4: With CR circuit
5: With LED indication, CR circuit
Coil voltage
06: 6, 12: 12, 24: 24, 48: 48 V
X0: 100/110 V AC, 100/110 V DC
X1: 110/120 V AC
Y0: 200/220 V AC, Y2: 220/240 V AC
Note: Products conform to UL/C-UL and TÜV, as standard.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
HK (AHK)
TYPES
1. Plug-in type
2. Plug-in type (with LED indication)
1 Form C
Part No.
2 Form C
Part No.
1 Form C
2 Form C
Part No.
Coil voltage
Coil voltage
Part No.
6V DC
12V DC
AHK12006
AHK12012
AHK12024
AHK12048
AHK120X0
AHK11012
AHK11024
AHK11048
AHK110X0
AHK110X1
AHK110Y0
AHK110Y2
AHK22006
AHK22012
AHK22024
AHK22048
AHK220X0
AHK21012
AHK21024
AHK21048
AHK210X0
AHK210X1
AHK210Y0
AHK210Y2
6V DC
12V DC
AHK12106
AHK12112
AHK12124
AHK12148
AHK121X0
AHK11112
AHK11124
AHK11148
AHK111X0
AHK111X1
AHK111Y0
AHK111Y2
AHK22106
AHK22112
AHK22124
AHK22148
AHK221X0
AHK21112
AHK21124
AHK21148
AHK211X0
AHK211X1
AHK211Y0
AHK211Y2
24V DC
24V DC
48V DC
48V DC
100/110V DC
12V AC
100/110V DC
12V AC
24V AC
24V AC
48V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
3. Plug-in type (with diode)
4. Plug-in type (with diode and LED indication)
1 Form C
2 Form C
Part No.
1 Form C
2 Form C
Coil voltage
Part No.
Coil voltage
Part No.
Part No.
6V DC
12V DC
AHK12206
AHK12212
AHK12224
AHK12248
AHK122X0
AHK22206
AHK22212
AHK22224
AHK22248
AHK222X0
6V DC
12V DC
AHK12306
AHK12312
AHK12324
AHK12348
AHK123X0
AHK22306
AHK22312
AHK22324
AHK22348
AHK223X0
24V DC
24V DC
48V DC
48V DC
100/110V DC
100/110V DC
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
5. Plug-in type (with CR)
6. Plug-in type (with CR and LED indication)
1 Form C
2 Form C
Part No.
1 Form C
2 Form C
Part No.
Coil voltage
Part No.
Coil voltage
Part No.
100/110V AC
110/120V AC
200/220V AC
220/240V AC
AHK114X0
AHK114X1
AHK114Y0
AHK114Y2
AHK214X0
AHK214X1
AHK214Y0
AHK214Y2
100/110V AC
110/120V AC
200/220V AC
220/240V AC
AHK115X0
AHK115X1
AHK115Y0
AHK115Y2
AHK215X0
AHK215X1
AHK215Y0
AHK215Y2
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
7. Accessories
Type
No. of poles
1/2 poles (common)
Item
HK screw terminal socket
HK screw terminal socket (Finger protect type)
Part No.
AHKA21
Terminal socket
AHKA21P
Standard packing: Carton: 10 pcs.; Case: 100 pcs.
Notes: 1. Use the retainer that is shipped with the terminal socket.
2. Products conform to UL, C-UL and TÜV, as standard.
3. In order to prevent breakage and disfiguring, the screw tightening torque for the terminal socket should be within the range of 0.784 to 0.98 N·m.
4. When attaching directly to a chassis, please use an M4 × 12 metric coarse screw thread, a spring washer, and a hexagonal nut.
Type
No. of poles
1-pole
Item
HL1 socket
Part No.
HL1-SS-K
HL2-SS-K
HL1-PS-K
HL2-PS-K
Plug-in socket
2-pole
HL2 socket
1-pole
HL1 PC board socket
HL2 PC board socket
PC board socket
2-pole
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Notes: 1. Use the retainer that is shipped with the terminal socket.
2. Products conform to UL/CSA as standard (TÜV is unacquired.)
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
HK (AHK)
RATING
1. Coil data
1) AC coils
Nominal coil current,
mA
Nominal operating power,
V A
Inductance, H
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Max. allowable
voltage
Coil voltage
When
When
operating
50Hz
60Hz
50Hz
60Hz
drop-out
0.312
1.243
4.974
23.75
27.19
85.98
12V AC
24V AC
111
56
100
50
1.3
1.3
1.3
1.3
1.3
1.3
1.2
1.2
1.2
1.2
1.2
1.2
0.295
1.181
4.145
20.63
25.57
81.76
80%V or less of
nominal voltage
(Initial)
30%V or more of
nominal voltage
(Initial)
48V AC
28
25
110%V of
nominal voltage
100/110V AC
110/120V AC
200/220V AC
13.4/14.7
12.2/13.5
6.7/7.4
12/13.2
10.9/11.9
6/6.6
Notes: 1. The relay operates in a range of 80% to 110 % V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the
rated voltage. In particular, for AC operation, if the impressed voltage drops to 80% V or more below the rated voltage, humming will occur and a large current will
flow leading possibly to coil burnout.
2. The maximum allowable voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.
(This value differs depending on the ambient temperature. Please contact us for details.)
2) DC coils (at 20°C 68°F)
Nominal coil current,
mA
Nominal operating
power, W
Coil resistance,
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Max. allowable voltage
Coil voltage
Ω
(at 70°C 158°F)
6V DC
12V DC
150
75
0.9
0.9
0.9
0.9
1.0
40
160
80%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
24V DC
37
650
48V DC
18.5
10
2,600
10,000
100/110V DC
Notes) 1. The rated excitation current is 10% (20°C 68°F).
2. The coil resistance for DC operation is the value measured when the coil temperature is 20°C 68°F. Compensate 0.4% for every 1°C change in temperature.
3. The relay operates in a range of 80% to 110 % V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the
rated voltage.
4. For use with 200 V DC, connect a 10 KΩ (5W) resistor, in series, to the 100 V DC relay.
5. The maximum allowable voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.
(This value differs depending on the ambient temperature. Please contact us for details.)
2. Specifications
Characteristics
Item
Initial contact resistance, max
Contact material
Specifications
Max. 50 mΩ (By voltage drop 6 V DC 1A)
AgSnO2 type
Contact
Nominal switching capacity
Max. switching voltage
1 Form C: 15A 125V AC 2 Form C: 10A 125V AC
250V AC, 125V DC
Rating
Max. switching current
Min. switching capacity (Reference value)*1
15A (1 Form C), 10A (2 Form C)
100mA 5V DC
Min. 100MΩ (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
Insulation resistance (Initial)
Between open contacts
1,000 Vrms for 1min. (Detection current: 10mA.)
Breakdown voltage
Between contact sets
(Initial)
2,000 Vrms for 1min. (Detection current: 10mA.)
Electrical
characteristics
Between contact and coil
2,000 Vrms for 1min. (Detection current: 10mA.)
Temperature rise
Max. 80°C (By resistive method, nominal voltage)
Operate time (at 20°C 68°F)*2
Max. 25ms (Nominal voltage applied to the coil, excluding contact bounce time.)
Max. 25ms (Nominal voltage applied to the coil, excluding contact bounce time.)
(without diode)
Release time (at 20°C 68°F)*2
Functional
Shock resistance
Min. 196 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
Destructive
Mechanical
characteristics
Functional
Vibration resistance
Destructive
10 to 55 Hz at double amplitude of 1 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 2 mm
Mechanical
AC type: 5×107 (at 180 cpm), DC type: 108 (at 180 cpm)
1 Form C: 15A 125V AC (cosϕ=1), Min. 2×105
Expected life
Electrical
AC load
2 Form C: 10A 125V AC (cosϕ=1), Min. 5×105
Ambient temperature:
–50°C to +70°C –58°F to +158°F (Without LED indication);
–50°C to +60°C –58°F to +140°F (With LED indication)
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Conditions for operation, transport and storage*3
Max. Operating speed
Conditions
Unit weight
20 cpm (at max. rating)
Approx. 35g 1.23 oz
Notes: If integrating into electrical appliances that will be subject to compliance to the Electrical Appliance and Material Safety Law, please use in an ambient temperature
between –50°C to +40°C –58°F to +104°F (AC type).
*1 This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the
actual load.
*2 For the AC coil types, the operate/release time will differ depending on the phase.
*3 The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value.Refer to 4. Conditions for operation,
transport and storage mentioned in AMBIENT ENVIRONMENT.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
HK (AHK)
REFERENCE DATA
1-(1). Max. switching capacity (1 Form C type)
1-(2). Max. switching capacity (2 Form C type)
2-(1). Coil temperature rise (1 Form C/AC type)
Measured portion: Inside the coil
Ambient temperature: 70°C 158°F
90
15
15A
AC resistive load
10
AC resistive load
10
80
70
5
5
0A
60
50
40
30
20
10
0
1
1
100
250 500
80
100
120
100
250 500
Contact voltage, V
Coil applied voltage, %V
Contact voltage, V
2-(2). Coil temperature rise (1 Form C/DC type)
2-(3). Coil temperature rise (2 Form C/AC type)
2-(4). Coil temperature rise (2 Form C/DC type)
Measured portion: Inside the coil
Ambient temperature: 70°C 158°F
Measured portion: Inside the coil
Ambient temperature: 70°C 158°F
Measured portion: Inside the coil
Ambient temperature: 70°C 158°F
90
80
70
90
90
80
70
10A
0A
80
70
60
50
40
30
20
10
0
15A
10A
60
60
50
50
0A
0A
40
40
30
20
10
0
30
20
10
0
80
100
120
80
100
120
80
100
120
Coil applied voltage, %V
Coil applied voltage, %V
Coil applied voltage, %V
3-(1). AC coil surge voltage waveform
(With CR)
3-(2). AC coil surge voltage waveform
(Without CR)
4-(1). DC coil surge voltage waveform
(Without diode)
ON
OFF
282V
282V
80V
Approx.
260V
Approx.
630V
To digital
memory
To digital
memory
To digital
memory
AC200V
DC12V
AC200V
4-(2). DC coil surge voltage waveform
(With diode)
Diode characteristics:
Reverse breakdown voltage: 1,000 V
Forward current: 1 A
ON
OFF
To digital
memory
DC12V
Reverse breakdown voltage: 1,000 V
Forward current: 1 A
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
HK (AHK)
DIMENSIONS (Unit: mm inch)
1. Plug-in type (1 Form C) including diode/CR
External dimensions
Schematic (Bottom view)
Standard type
20.8
.819
27.2
1.071
2
3
7
6
8
LED AC type
Diode DC type
CR AC type
LED DC type
2
2
35.4
1.394
3
7
3
6
8
6
8
7
Diode/LED DC type
6.35
.250
2
2
3
7
3
10
.394
Compatible with tab terminal
#187 series receptacle.
6
8
6
7
8
3.95
2
6
.156
4.6
3
.181
CR/LED AC type
6
.236
2
2
7.15
.281
3
7
3
7
6
8
6
8
7
8
14.2
.559
General tolerance: 0.3 .012
2. Plug-in type (2 Form C) including diode/CR
External dimensions
Schematic (Bottom view)
Standard type
20.8
.819
27.2
1.071
1
3
5
2
4
6
7
8
LED AC type
LED DC type
1
3
5
2
4
6
1
3
5
2
4
6
35.4
1.394
7
8
7
8
Diode DC type
CR AC type
Diode/LED DC type
6.35
.250
1
3
5
2
4
6
1
3
5
2
4
6
Compatible with tab terminal
#187 series receptacle.
10
.394
7
8
7
8
3.7
1
3
2
4
.146
4.7
.185
CR/LED AC type
6
.236
5
6
1
3
5
2
4
6
1
3
5
2
4
6
7.3
.287
7
8
7
8
7
8
14.2
.559
General tolerance: 0.3 .012
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
HK (AHK)
3. Screw terminal socket
HK screw terminal socket
External dimensions
Schematic (Bottom view)
Mounting hole dimensions
7
.276
2-4.5 dia.
2-.177 dia.
2
1
2-4.5×6 2-.177×6
mounting holes
Max. 30
Max. 1.181
M3.5 .138
terminal screw
3.4
.134
4
3
68 0.3
2.677 .012
Max. 78.5
Max. 3.091
35.4
1.394
6
8
5
7
19 0.2
.748 .008
Max. 28.5
Max. 1.122
8
.315
General tolerance: 0.5 .020
HK screw terminal socket (Finger protect type)
External dimensions
Schematic (Bottom view)
Mounting hole dimensions
7
.276
Max. 33
2-4.5 dia.
2-.177 dia.
2
1
Max. 1.299
2-4.5×6 2-.177×6
M3.5 .138
terminal screw
30
1.181
mounting holes
3.4
.134
4
3
68 0.3
2.677 .012
Max. 78.5
Max. 3.091
35.4
1.394
6
8
5
7
19 0.2
.748 .008
8
.315
Max. 28.5
Max. 1.122
General tolerance: 0.5 .020
Note: Round type terminal is unable to attach.
4. Plug-in type sockets
HL1 socket External dimensions
Hold-down clip
Compatible with tab
terminal #187 series
receptacle.
Note: The external and mounting
dimensions are the same for
HL2 socket (HL2-SS-K).
Only the number of
25.5
1.004
terminals varies.
29.4
1.157
HL1 Socket (HL1-SS-K)
11.2
.441
18.7
.736
Hold-down clip is packaged with the socket.
General tolerance: 0.3 .012
HL2 Socket (HL2-SS-K)
Mounting hole diagram
Side-by-side installation
25.8
1.016
8.9
.350
Notes: 1. Applicable chassis board thickness is 1.0 to
2.0 mm.
25.8
1.016
2. Installation is easy by inserting the socket
from the top into the holes and by
depressing the two down arrows on the
retention fitting from the front.
5.9
.232
21.6
.850
21.6
.850
Tolerance: 0.1 .004
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
HK (AHK)
Hold-down clip
5. PC board type sockets
HL2 PC board type socket
External dimensions
21.2
.835
Note: The external and mounting
dimensions are the same for
HL1 PC board type socket
(HL1-PS-K). Only the
29.4
1.157
number of terminals varies.
HL1 PC board type socket
(HL1-PS-K)
2.0
.079
1.0
.039
11.2
.441
16.2
.638
Hold-down clip is packaged with the socket.
General tolerance: 0.3 .012
HL2 PC board type socket
(HL2-PS-K)
PC board pattern (Bottom view)
Side-by-side installation (For 2 Form C)
10
.394
13.2
.520
10
.394
1 Form C
2 Form C
2.4 dia. hole
.094 dia.
10
.394
4.7
.185
17.45
.687
17.45
.687
17.45
.687
12.75
.502
(6.6)
(.260)
6.75
.266
6.75
.266
17.25
.679
15.3
.602
10
.394
(5.3)
(.209)
15.3
.602
17.45
.687
Tolerance: 0.1 .004
15.3
.602
2.4 dia. hole
.094 dia.
7.9
.311
15.3
.602
Tolerance: 0.1 .004
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
HK (AHK)
NOTES
1. Coil operating power
1) When used for AC load-operating and
the operating phase is synchronous.
Rocking and fusing can easily occur due
to contact shifting.
2) High-frequency load operating
When high-frequency opening and
closing of the relay is performed with a
load that causes arcs at the contacts,
nitrogen and oxygen in the air is fused by
the arc energy and HNO3 is formed. This
can corrode metal materials.
Three countermeasures for these are
listed here.
(1) Incorporate an arc-extinguishing
circuit.
(2) Lower the operating frequency
(3) Lower the ambient humidity
4. Conditions for operation, transport and
storage
2) Condensation
1) DC coil
Condensation forms when there is a
sudden change in temperature under
high temperature and high humidity
conditions. Condensation will cause
deterioration of the relay insulation.
3) Freezing
To ensure proper operation, the voltage
applied to both terminals of the coil
should be 5% (at 20°C 68°F) the rated
operating voltage of the coil. Also, be
aware that the pick-up and dropout
voltages will fluctuate depending on the
ambient temperature and operating
conditions.
Condensation or other moisture may
freeze on the relay when the
temperatures is lower than 0°C 32°F. This
causes problems such as sticking of
movable parts or operational time lags.
4) Low temperature, low humidity
environments
The plastic becomes brittle if the relay is
exposed to a low temperature, low
humidity environment for long periods of
time.
2) AC Coil
To enable stable operation of the relay,
apply the nominal voltage. Ensure that
the fluctuation range of the power source
voltage remains, in principle, within +10%
to –15% of the value of the nominal
current. Moreover, the ideal waveform for
the voltage applied to the coil is a sine
curve. If commercially provided power
surce is used, the waveform should be
checked. If a stabilized AC power source
is used, the conditioning equipment may
distort the waveform, and abnormal
heating may result. With AC coils, hum
can be normally stopped by the use of a
shading coil. If the waveform is distorted,
however, the shading coil may be
ineffective.
5. Diode characteristics
1) Reverse breakdown voltage: 1,000 V
2) Forward current: 1 A
1) Ambient temperature, humidity, and
atmospheric pressure during usage,
transport, and storage of the relay:
(1) Temperature:
–50 to +70°C (without LED)
–50 to +60°C (with LED)
6. Diode and CR built-in type
Since the diode and CR inside the relay
coil are designed to absorb the counter
emf, the element may be damaged if a
large surge, etc., is applied to the diode
and CR.
If there is the possibility of a large surge
voltage from the outside, please
implement measures to absorb it
(2) Humidity: 5 to 85% RH (Avoid
freezing and condensation.)
The humidity range varies with the
temperature. Use within the range
indicated in the graph below.
Temperature and humidity range for
usage, transport, and storage
2. LED indications
The light of the light emitting diode is
what displays operation. If voltage
remains after relay might illuminate
briefly.
Humidity, %R.H.
3. Switching lifetime
The switching lifetime is defined under
the standard test condition specified in
the JIS C 5442(*2) standard (temperature
15 to 35°C 59 to 95°F, humidity 25 to
75% R.H.). Check this with the real
device as it is affected by coil driving
circuit, load type, activation frequency,
activation phase, ambient conditions and
other factors. Also, be especially careful
of loads such as those listed below.
85
Tolerance range
(Avoid freezing when
used at temperatures
lower than 0°C 32°F)
(Avoid
condensation when
used at temperatures
higher than 0°C 32°F)
5
–50
0
+70
–58
+32
+158
Temperature, °C °F
(3) Atmospheric pressure: 86 to 106kPa
For Cautions for Use, see Relay Technical Information.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
相关型号:
AHK11048
Power/Signal Relay, SPDT, Momentary, 1300mW (Coil), 15A (Contact), 125VDC (Contact), AC Input, AC/DC Output, Socket Mount, CADMIUM FREE AND ROHS COMPLIANT
PANASONIC
AHK110X0
Power/Signal Relay, SPDT, Momentary, 1300mW (Coil), 15A (Contact), 125VDC (Contact), AC Input, AC/DC Output, Socket Mount, CADMIUM FREE AND ROHS COMPLIANT
PANASONIC
AHK110Y0
Power/Signal Relay, SPDT, Momentary, 1300mW (Coil), 15A (Contact), 125VDC (Contact), AC Input, AC/DC Output, Socket Mount, CADMIUM FREE AND ROHS COMPLIANT
PANASONIC
AHK11112
Power/Signal Relay, SPDT, Momentary, 1300mW (Coil), 15A (Contact), 125VDC (Contact), AC Input, AC/DC Output, Socket Mount, CADMIUM FREE AND ROHS COMPLIANT
PANASONIC
AHK11124
Power/Signal Relay, SPDT, Momentary, 1300mW (Coil), 15A (Contact), 125VDC (Contact), AC Input, AC/DC Output, Socket Mount, CADMIUM FREE AND ROHS COMPLIANT
PANASONIC
AHK11148
Power/Signal Relay, SPDT, Momentary, 1300mW (Coil), 15A (Contact), 125VDC (Contact), AC Input, AC/DC Output, Socket Mount, CADMIUM FREE AND ROHS COMPLIANT
PANASONIC
©2020 ICPDF网 联系我们和版权申明