AHK11048 [PANASONIC]

Power/Signal Relay, SPDT, Momentary, 1300mW (Coil), 15A (Contact), 125VDC (Contact), AC Input, AC/DC Output, Socket Mount, CADMIUM FREE AND ROHS COMPLIANT;
AHK11048
型号: AHK11048
厂家: PANASONIC    PANASONIC
描述:

Power/Signal Relay, SPDT, Momentary, 1300mW (Coil), 15A (Contact), 125VDC (Contact), AC Input, AC/DC Output, Socket Mount, CADMIUM FREE AND ROHS COMPLIANT

光电二极管 继电器
文件: 总8页 (文件大小:167K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
COMPACT AND  
HIGH CAPACITY  
GENERAL PURPOSE  
POWER RELAYS  
HK RELAYS (AHK)  
FEATURES  
TYPICAL APPLICATIONS  
1. Economical prices achieved  
To assist rationalization, prices reduced  
to about half the price of previous  
products.  
Control panels  
Power supply units  
Molding machines  
Machine tools  
2. Compact with high-capacity  
Enables high-capacity control:  
Welding equipment  
Agricultural equipment  
Office equipment  
Vending machines  
Communications equipment  
Amusement machines, etc.  
15 A for 1 Form C, 10 A for 2 Form C  
3.Types for wide range of applications  
Range includes relays with operation  
indicators, built-in diodes to absorb relay  
coil surge, and built-in CR circuits.  
4. Cadmium-free contacts  
5. UL/C-UL and TÜV approved parts  
available. Compliance with Japanese  
Electrical Appliance and Material  
Control Law is standard.  
Compliance with RoHS Directive  
ORDERING INFORMATION  
AHK  
HK relays  
Contact arrangement  
1: 1 Form C  
2: 2 Form C  
Terminal arrangement  
1: AC plug-in type  
2: DC plug-in type  
Type classification  
0: Standard  
1: With LED indication  
2: With diode  
3: With LED indication, diode  
4: With CR circuit  
5: With LED indication, CR circuit  
Coil voltage  
06: 6, 12: 12, 24: 24, 48: 48 V  
X0: 100/110 V AC, 100/110 V DC  
X1: 110/120 V AC  
Y0: 200/220 V AC, Y2: 220/240 V AC  
Note: Products conform to UL/C-UL and TÜV, as standard.  
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.  
HK (AHK)  
TYPES  
1. Plug-in type  
2. Plug-in type (with LED indication)  
1 Form C  
Part No.  
2 Form C  
Part No.  
1 Form C  
2 Form C  
Part No.  
Coil voltage  
Coil voltage  
Part No.  
6V DC  
12V DC  
AHK12006  
AHK12012  
AHK12024  
AHK12048  
AHK120X0  
AHK11012  
AHK11024  
AHK11048  
AHK110X0  
AHK110X1  
AHK110Y0  
AHK110Y2  
AHK22006  
AHK22012  
AHK22024  
AHK22048  
AHK220X0  
AHK21012  
AHK21024  
AHK21048  
AHK210X0  
AHK210X1  
AHK210Y0  
AHK210Y2  
6V DC  
12V DC  
AHK12106  
AHK12112  
AHK12124  
AHK12148  
AHK121X0  
AHK11112  
AHK11124  
AHK11148  
AHK111X0  
AHK111X1  
AHK111Y0  
AHK111Y2  
AHK22106  
AHK22112  
AHK22124  
AHK22148  
AHK221X0  
AHK21112  
AHK21124  
AHK21148  
AHK211X0  
AHK211X1  
AHK211Y0  
AHK211Y2  
24V DC  
24V DC  
48V DC  
48V DC  
100/110V DC  
12V AC  
100/110V DC  
12V AC  
24V AC  
24V AC  
48V AC  
48V AC  
100/110V AC  
110/120V AC  
200/220V AC  
220/240V AC  
100/110V AC  
110/120V AC  
200/220V AC  
220/240V AC  
Standard packing: Carton: 20 pcs.; Case: 200 pcs.  
Standard packing: Carton: 20 pcs.; Case: 200 pcs.  
3. Plug-in type (with diode)  
4. Plug-in type (with diode and LED indication)  
1 Form C  
2 Form C  
Part No.  
1 Form C  
2 Form C  
Coil voltage  
Part No.  
Coil voltage  
Part No.  
Part No.  
6V DC  
12V DC  
AHK12206  
AHK12212  
AHK12224  
AHK12248  
AHK122X0  
AHK22206  
AHK22212  
AHK22224  
AHK22248  
AHK222X0  
6V DC  
12V DC  
AHK12306  
AHK12312  
AHK12324  
AHK12348  
AHK123X0  
AHK22306  
AHK22312  
AHK22324  
AHK22348  
AHK223X0  
24V DC  
24V DC  
48V DC  
48V DC  
100/110V DC  
100/110V DC  
Standard packing: Carton: 20 pcs.; Case: 200 pcs.  
Standard packing: Carton: 20 pcs.; Case: 200 pcs.  
5. Plug-in type (with CR)  
6. Plug-in type (with CR and LED indication)  
1 Form C  
2 Form C  
Part No.  
1 Form C  
2 Form C  
Part No.  
Coil voltage  
Part No.  
Coil voltage  
Part No.  
100/110V AC  
110/120V AC  
200/220V AC  
220/240V AC  
AHK114X0  
AHK114X1  
AHK114Y0  
AHK114Y2  
AHK214X0  
AHK214X1  
AHK214Y0  
AHK214Y2  
100/110V AC  
110/120V AC  
200/220V AC  
220/240V AC  
AHK115X0  
AHK115X1  
AHK115Y0  
AHK115Y2  
AHK215X0  
AHK215X1  
AHK215Y0  
AHK215Y2  
Standard packing: Carton: 20 pcs.; Case: 200 pcs.  
Standard packing: Carton: 20 pcs.; Case: 200 pcs.  
7. Accessories  
Type  
No. of poles  
1/2 poles (common)  
Item  
HK screw terminal socket  
HK screw terminal socket (Finger protect type)  
Part No.  
AHKA21  
Terminal socket  
AHKA21P  
Standard packing: Carton: 10 pcs.; Case: 100 pcs.  
Notes: 1. Use the retainer that is shipped with the terminal socket.  
2. Products conform to UL, C-UL and TÜV, as standard.  
3. In order to prevent breakage and disfiguring, the screw tightening torque for the terminal socket should be within the range of 0.784 to 0.98 N·m.  
4. When attaching directly to a chassis, please use an M4 × 12 metric coarse screw thread, a spring washer, and a hexagonal nut.  
Type  
No. of poles  
1-pole  
Item  
HL1 socket  
Part No.  
HL1-SS-K  
HL2-SS-K  
HL1-PS-K  
HL2-PS-K  
Plug-in socket  
2-pole  
HL2 socket  
1-pole  
HL1 PC board socket  
HL2 PC board socket  
PC board socket  
2-pole  
Standard packing: Carton: 20 pcs.; Case: 200 pcs.  
Notes: 1. Use the retainer that is shipped with the terminal socket.  
2. Products conform to UL/CSA as standard (TÜV is unacquired.)  
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.  
HK (AHK)  
RATING  
1. Coil data  
1) AC coils  
Nominal coil current,  
mA  
Nominal operating power,  
V A  
Inductance, H  
Pick-up voltage  
(at 20°C 68°F)  
Drop-out voltage  
(at 20°C 68°F)  
Max. allowable  
voltage  
Coil voltage  
When  
When  
operating  
50Hz  
60Hz  
50Hz  
60Hz  
drop-out  
0.312  
1.243  
4.974  
23.75  
27.19  
85.98  
12V AC  
24V AC  
111  
56  
100  
50  
1.3  
1.3  
1.3  
1.3  
1.3  
1.3  
1.2  
1.2  
1.2  
1.2  
1.2  
1.2  
0.295  
1.181  
4.145  
20.63  
25.57  
81.76  
80%V or less of  
nominal voltage  
(Initial)  
30%V or more of  
nominal voltage  
(Initial)  
48V AC  
28  
25  
110%V of  
nominal voltage  
100/110V AC  
110/120V AC  
200/220V AC  
13.4/14.7  
12.2/13.5  
6.7/7.4  
12/13.2  
10.9/11.9  
6/6.6  
Notes: 1. The relay operates in a range of 80% to 110 % V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the  
rated voltage. In particular, for AC operation, if the impressed voltage drops to 80% V or more below the rated voltage, humming will occur and a large current will  
flow leading possibly to coil burnout.  
2. The maximum allowable voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.  
(This value differs depending on the ambient temperature. Please contact us for details.)  
2) DC coils (at 20°C 68°F)  
Nominal coil current,  
mA  
Nominal operating  
power, W  
Coil resistance,  
Pick-up voltage  
(at 20°C 68°F)  
Drop-out voltage  
(at 20°C 68°F)  
Max. allowable voltage  
Coil voltage  
(at 70°C 158°F)  
6V DC  
12V DC  
150  
75  
0.9  
0.9  
0.9  
0.9  
1.0  
40  
160  
80%V or less of  
nominal voltage  
(Initial)  
10%V or more of  
nominal voltage  
(Initial)  
110%V of  
nominal voltage  
24V DC  
37  
650  
48V DC  
18.5  
10  
2,600  
10,000  
100/110V DC  
Notes) 1. The rated excitation current is 10% (20°C 68°F).  
2. The coil resistance for DC operation is the value measured when the coil temperature is 20°C 68°F. Compensate 0.4% for every 1°C change in temperature.  
3. The relay operates in a range of 80% to 110 % V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the  
rated voltage.  
4. For use with 200 V DC, connect a 10 K(5W) resistor, in series, to the 100 V DC relay.  
5. The maximum allowable voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.  
(This value differs depending on the ambient temperature. Please contact us for details.)  
2. Specifications  
Characteristics  
Item  
Initial contact resistance, max  
Contact material  
Specifications  
Max. 50 m(By voltage drop 6 V DC 1A)  
AgSnO2 type  
Contact  
Nominal switching capacity  
Max. switching voltage  
1 Form C: 15A 125V AC 2 Form C: 10A 125V AC  
250V AC, 125V DC  
Rating  
Max. switching current  
Min. switching capacity (Reference value)*1  
15A (1 Form C), 10A (2 Form C)  
100mA 5V DC  
Min. 100M(at 500V DC)  
Measurement at same location as “Initial breakdown voltage” section.  
Insulation resistance (Initial)  
Between open contacts  
1,000 Vrms for 1min. (Detection current: 10mA.)  
Breakdown voltage  
Between contact sets  
(Initial)  
2,000 Vrms for 1min. (Detection current: 10mA.)  
Electrical  
characteristics  
Between contact and coil  
2,000 Vrms for 1min. (Detection current: 10mA.)  
Temperature rise  
Max. 80°C (By resistive method, nominal voltage)  
Operate time (at 20°C 68°F)*2  
Max. 25ms (Nominal voltage applied to the coil, excluding contact bounce time.)  
Max. 25ms (Nominal voltage applied to the coil, excluding contact bounce time.)  
(without diode)  
Release time (at 20°C 68°F)*2  
Functional  
Shock resistance  
Min. 196 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)  
Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)  
Destructive  
Mechanical  
characteristics  
Functional  
Vibration resistance  
Destructive  
10 to 55 Hz at double amplitude of 1 mm (Detection time: 10µs.)  
10 to 55 Hz at double amplitude of 2 mm  
Mechanical  
AC type: 5×107 (at 180 cpm), DC type: 108 (at 180 cpm)  
1 Form C: 15A 125V AC (cosϕ=1), Min. 2×105  
Expected life  
Electrical  
AC load  
2 Form C: 10A 125V AC (cosϕ=1), Min. 5×105  
Ambient temperature:  
–50°C to +70°C –58°F to +158°F (Without LED indication);  
–50°C to +60°C –58°F to +140°F (With LED indication)  
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)  
Conditions for operation, transport and storage*3  
Max. Operating speed  
Conditions  
Unit weight  
20 cpm (at max. rating)  
Approx. 35g 1.23 oz  
Notes: If integrating into electrical appliances that will be subject to compliance to the Electrical Appliance and Material Safety Law, please use in an ambient temperature  
between –50°C to +40°C –58°F to +104°F (AC type).  
*1 This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the  
actual load.  
*2 For the AC coil types, the operate/release time will differ depending on the phase.  
*3 The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value.Refer to 4. Conditions for operation,  
transport and storage mentioned in AMBIENT ENVIRONMENT.  
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.  
HK (AHK)  
REFERENCE DATA  
1-(1). Max. switching capacity (1 Form C type)  
1-(2). Max. switching capacity (2 Form C type)  
2-(1). Coil temperature rise (1 Form C/AC type)  
Measured portion: Inside the coil  
Ambient temperature: 70°C 158°F  
90  
15  
15A  
AC resistive load  
10  
AC resistive load  
10  
80  
70  
5
5
0A  
60  
50  
40  
30  
20  
10  
0
1
1
100  
250 500  
80  
100  
120  
100  
250 500  
Contact voltage, V  
Coil applied voltage, %V  
Contact voltage, V  
2-(2). Coil temperature rise (1 Form C/DC type)  
2-(3). Coil temperature rise (2 Form C/AC type)  
2-(4). Coil temperature rise (2 Form C/DC type)  
Measured portion: Inside the coil  
Ambient temperature: 70°C 158°F  
Measured portion: Inside the coil  
Ambient temperature: 70°C 158°F  
Measured portion: Inside the coil  
Ambient temperature: 70°C 158°F  
90  
80  
70  
90  
90  
80  
70  
10A  
0A  
80  
70  
60  
50  
40  
30  
20  
10  
0
15A  
10A  
60  
60  
50  
50  
0A  
0A  
40  
40  
30  
20  
10  
0
30  
20  
10  
0
80  
100  
120  
80  
100  
120  
80  
100  
120  
Coil applied voltage, %V  
Coil applied voltage, %V  
Coil applied voltage, %V  
3-(1). AC coil surge voltage waveform  
(With CR)  
3-(2). AC coil surge voltage waveform  
(Without CR)  
4-(1). DC coil surge voltage waveform  
(Without diode)  
ON  
OFF  
282V  
282V  
80V  
Approx.  
260V  
Approx.  
630V  
To digital  
memory  
To digital  
memory  
To digital  
memory  
AC200V  
DC12V  
AC200V  
4-(2). DC coil surge voltage waveform  
(With diode)  
Diode characteristics:  
Reverse breakdown voltage: 1,000 V  
Forward current: 1 A  
ON  
OFF  
To digital  
memory  
DC12V  
Reverse breakdown voltage: 1,000 V  
Forward current: 1 A  
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.  
HK (AHK)  
DIMENSIONS (Unit: mm inch)  
1. Plug-in type (1 Form C) including diode/CR  
External dimensions  
Schematic (Bottom view)  
Standard type  
20.8  
.819  
27.2  
1.071  
2
3
7
6
8
LED AC type  
Diode DC type  
CR AC type  
LED DC type  
2
2
35.4  
1.394  
3
7
3
6
8
6
8
7
Diode/LED DC type  
6.35  
.250  
2
2
3
7
3
10  
.394  
Compatible with tab terminal  
#187 series receptacle.  
6
8
6
7
8
3.95  
2
6
.156  
4.6  
3
.181  
CR/LED AC type  
6
.236  
2
2
7.15  
.281  
3
7
3
7
6
8
6
8
7
8
14.2  
.559  
General tolerance: 0.3 .012  
2. Plug-in type (2 Form C) including diode/CR  
External dimensions  
Schematic (Bottom view)  
Standard type  
20.8  
.819  
27.2  
1.071  
1
3
5
2
4
6
7
8
LED AC type  
LED DC type  
1
3
5
2
4
6
1
3
5
2
4
6
35.4  
1.394  
7
8
7
8
Diode DC type  
CR AC type  
Diode/LED DC type  
6.35  
.250  
1
3
5
2
4
6
1
3
5
2
4
6
Compatible with tab terminal  
#187 series receptacle.  
10  
.394  
7
8
7
8
3.7  
1
3
2
4
.146  
4.7  
.185  
CR/LED AC type  
6
.236  
5
6
1
3
5
2
4
6
1
3
5
2
4
6
7.3  
.287  
7
8
7
8
7
8
14.2  
.559  
General tolerance: 0.3 .012  
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.  
HK (AHK)  
3. Screw terminal socket  
HK screw terminal socket  
External dimensions  
Schematic (Bottom view)  
Mounting hole dimensions  
7
.276  
2-4.5 dia.  
2-.177 dia.  
2
1
2-4.5×6 2-.177×6  
mounting holes  
Max. 30  
Max. 1.181  
M3.5 .138  
terminal screw  
3.4  
.134  
4
3
68 0.3  
2.677 .012  
Max. 78.5  
Max. 3.091  
35.4  
1.394  
6
8
5
7
19 0.2  
.748 .008  
Max. 28.5  
Max. 1.122  
8
.315  
General tolerance: 0.5 .020  
HK screw terminal socket (Finger protect type)  
External dimensions  
Schematic (Bottom view)  
Mounting hole dimensions  
7
.276  
Max. 33  
2-4.5 dia.  
2-.177 dia.  
2
1
Max. 1.299  
2-4.5×6 2-.177×6  
M3.5 .138  
terminal screw  
30  
1.181  
mounting holes  
3.4  
.134  
4
3
68 0.3  
2.677 .012  
Max. 78.5  
Max. 3.091  
35.4  
1.394  
6
8
5
7
19 0.2  
.748 .008  
8
.315  
Max. 28.5  
Max. 1.122  
General tolerance: 0.5 .020  
Note: Round type terminal is unable to attach.  
4. Plug-in type sockets  
HL1 socket External dimensions  
Hold-down clip  
Compatible with tab  
terminal #187 series  
receptacle.  
Note: The external and mounting  
dimensions are the same for  
HL2 socket (HL2-SS-K).  
Only the number of  
25.5  
1.004  
terminals varies.  
29.4  
1.157  
HL1 Socket (HL1-SS-K)  
11.2  
.441  
18.7  
.736  
Hold-down clip is packaged with the socket.  
General tolerance: 0.3 .012  
HL2 Socket (HL2-SS-K)  
Mounting hole diagram  
Side-by-side installation  
25.8  
1.016  
8.9  
.350  
Notes: 1. Applicable chassis board thickness is 1.0 to  
2.0 mm.  
25.8  
1.016  
2. Installation is easy by inserting the socket  
from the top into the holes and by  
depressing the two down arrows on the  
retention fitting from the front.  
5.9  
.232  
21.6  
.850  
21.6  
.850  
Tolerance: 0.1 .004  
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.  
HK (AHK)  
Hold-down clip  
5. PC board type sockets  
HL2 PC board type socket  
External dimensions  
21.2  
.835  
Note: The external and mounting  
dimensions are the same for  
HL1 PC board type socket  
(HL1-PS-K). Only the  
29.4  
1.157  
number of terminals varies.  
HL1 PC board type socket  
(HL1-PS-K)  
2.0  
.079  
1.0  
.039  
11.2  
.441  
16.2  
.638  
Hold-down clip is packaged with the socket.  
General tolerance: 0.3 .012  
HL2 PC board type socket  
(HL2-PS-K)  
PC board pattern (Bottom view)  
Side-by-side installation (For 2 Form C)  
10  
.394  
13.2  
.520  
10  
.394  
1 Form C  
2 Form C  
2.4 dia. hole  
.094 dia.  
10  
.394  
4.7  
.185  
17.45  
.687  
17.45  
.687  
17.45  
.687  
12.75  
.502  
(6.6)  
(.260)  
6.75  
.266  
6.75  
.266  
17.25  
.679  
15.3  
.602  
10  
.394  
(5.3)  
(.209)  
15.3  
.602  
17.45  
.687  
Tolerance: 0.1 .004  
15.3  
.602  
2.4 dia. hole  
.094 dia.  
7.9  
.311  
15.3  
.602  
Tolerance: 0.1 .004  
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.  
HK (AHK)  
NOTES  
1. Coil operating power  
1) When used for AC load-operating and  
the operating phase is synchronous.  
Rocking and fusing can easily occur due  
to contact shifting.  
2) High-frequency load operating  
When high-frequency opening and  
closing of the relay is performed with a  
load that causes arcs at the contacts,  
nitrogen and oxygen in the air is fused by  
the arc energy and HNO3 is formed. This  
can corrode metal materials.  
Three countermeasures for these are  
listed here.  
(1) Incorporate an arc-extinguishing  
circuit.  
(2) Lower the operating frequency  
(3) Lower the ambient humidity  
4. Conditions for operation, transport and  
storage  
2) Condensation  
1) DC coil  
Condensation forms when there is a  
sudden change in temperature under  
high temperature and high humidity  
conditions. Condensation will cause  
deterioration of the relay insulation.  
3) Freezing  
To ensure proper operation, the voltage  
applied to both terminals of the coil  
should be 5% (at 20°C 68°F) the rated  
operating voltage of the coil. Also, be  
aware that the pick-up and dropout  
voltages will fluctuate depending on the  
ambient temperature and operating  
conditions.  
Condensation or other moisture may  
freeze on the relay when the  
temperatures is lower than 0°C 32°F. This  
causes problems such as sticking of  
movable parts or operational time lags.  
4) Low temperature, low humidity  
environments  
The plastic becomes brittle if the relay is  
exposed to a low temperature, low  
humidity environment for long periods of  
time.  
2) AC Coil  
To enable stable operation of the relay,  
apply the nominal voltage. Ensure that  
the fluctuation range of the power source  
voltage remains, in principle, within +10%  
to –15% of the value of the nominal  
current. Moreover, the ideal waveform for  
the voltage applied to the coil is a sine  
curve. If commercially provided power  
surce is used, the waveform should be  
checked. If a stabilized AC power source  
is used, the conditioning equipment may  
distort the waveform, and abnormal  
heating may result. With AC coils, hum  
can be normally stopped by the use of a  
shading coil. If the waveform is distorted,  
however, the shading coil may be  
ineffective.  
5. Diode characteristics  
1) Reverse breakdown voltage: 1,000 V  
2) Forward current: 1 A  
1) Ambient temperature, humidity, and  
atmospheric pressure during usage,  
transport, and storage of the relay:  
(1) Temperature:  
–50 to +70°C (without LED)  
–50 to +60°C (with LED)  
6. Diode and CR built-in type  
Since the diode and CR inside the relay  
coil are designed to absorb the counter  
emf, the element may be damaged if a  
large surge, etc., is applied to the diode  
and CR.  
If there is the possibility of a large surge  
voltage from the outside, please  
implement measures to absorb it  
(2) Humidity: 5 to 85% RH (Avoid  
freezing and condensation.)  
The humidity range varies with the  
temperature. Use within the range  
indicated in the graph below.  
Temperature and humidity range for  
usage, transport, and storage  
2. LED indications  
The light of the light emitting diode is  
what displays operation. If voltage  
remains after relay might illuminate  
briefly.  
Humidity, %R.H.  
3. Switching lifetime  
The switching lifetime is defined under  
the standard test condition specified in  
the JIS C 5442(*2) standard (temperature  
15 to 35°C 59 to 95°F, humidity 25 to  
75% R.H.). Check this with the real  
device as it is affected by coil driving  
circuit, load type, activation frequency,  
activation phase, ambient conditions and  
other factors. Also, be especially careful  
of loads such as those listed below.  
85  
Tolerance range  
(Avoid freezing when  
used at temperatures  
lower than 0°C 32°F)  
(Avoid  
condensation when  
used at temperatures  
higher than 0°C 32°F)  
5
–50  
0
+70  
–58  
+32  
+158  
Temperature, °C °F  
(3) Atmospheric pressure: 86 to 106kPa  
For Cautions for Use, see Relay Technical Information.  
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.  

相关型号:

AHK110X0

Power/Signal Relay, SPDT, Momentary, 1300mW (Coil), 15A (Contact), 125VDC (Contact), AC Input, AC/DC Output, Socket Mount, CADMIUM FREE AND ROHS COMPLIANT
PANASONIC

AHK110Y0

Power/Signal Relay, SPDT, Momentary, 1300mW (Coil), 15A (Contact), 125VDC (Contact), AC Input, AC/DC Output, Socket Mount, CADMIUM FREE AND ROHS COMPLIANT
PANASONIC

AHK11112

Power/Signal Relay, SPDT, Momentary, 1300mW (Coil), 15A (Contact), 125VDC (Contact), AC Input, AC/DC Output, Socket Mount, CADMIUM FREE AND ROHS COMPLIANT
PANASONIC

AHK11124

Power/Signal Relay, SPDT, Momentary, 1300mW (Coil), 15A (Contact), 125VDC (Contact), AC Input, AC/DC Output, Socket Mount, CADMIUM FREE AND ROHS COMPLIANT
PANASONIC

AHK11148

Power/Signal Relay, SPDT, Momentary, 1300mW (Coil), 15A (Contact), 125VDC (Contact), AC Input, AC/DC Output, Socket Mount, CADMIUM FREE AND ROHS COMPLIANT
PANASONIC

AHK1117

1 Amp Linear Regulator
ANALOGICTECH

AHK1117XMY-33-B1

1 Amp Linear Regulator
ANALOGICTECH

AHK1117XMY-33-T1

1 Amp Linear Regulator
ANALOGICTECH

AHK1117XMY-ADJ-B1

1 Amp Linear Regulator
ANALOGICTECH

AHK1117XMY-ADJ-T1

1 Amp Linear Regulator
ANALOGICTECH

AHK1117XNY-33-T1

1 Amp Linear Regulator
ANALOGICTECH

AHK1117XNY-ADJ-T1

1 Amp Linear Regulator
ANALOGICTECH