Dual PWM Fan Controller and Temperature  
Monitor for High Availability Systems  
ADM1029*  
FEATURES  
Supports Hot Swapping of Fans  
Software Programmable and Automatic Fan Speed  
Control  
Cascadable Fault Output Allows Fault Signaling  
between Multiple ADM1029s  
Automatic Fan Speed Control Allows Control  
Independent of CPU Intervention after Initial Setup  
Control Loop Minimizes Acoustic Noise and Power  
Consumption  
Address Pin Allows Up to Eight ADM1029s in A System  
Small 24-Lead QSOP Package  
APPLICATIONS  
Network Servers and Personal Computers  
Microprocessor-Based Office Equipment  
High Availability Telecommunications Equipment  
Remote and Local Temperature Monitoring  
Dual Fan Speed Measurement  
Supports Backup and Redundant Fans  
FUNCTIONAL BLOCK DIAGRAM  
V
CC  
SCL  
SDA  
SERIAL BUS  
INTERFACE  
ADM1029  
ADDRESS POINTER  
REGISTER  
SLAVE ADDRESS  
REGISTER  
INTERRUPT MASK  
REGISTERS  
INT  
INTERRUPT  
MASKING  
PRESENT1  
FAULT1  
FAN 1 STATUS  
REGISTER  
INTERRUPT STATUS  
REGISTERS  
CFAULT  
FAN 1 MIN  
SPEED REGISTER  
PWM  
CONTROLLER  
FAN 1 ALARM  
SPEED REGISTER  
LIMIT COMPARATOR  
DRIVE1  
FAN 1 HOT-PLUG  
SPEED REGISTER  
RESET  
VALUE AND LIMIT  
REGISTERS  
GPIO2  
TACH1  
TACH2  
G.P. I/O REGISTER  
FAN SPEED  
COUNTER  
PRESENT2  
FAN 2 STATUS  
REGISTER  
AIN1/GPIO1  
AIN0/GPIO0  
D2+/GPIO6  
D2–/GPIO5  
FAULT2  
FAN 2 MIN  
SPEED REGISTER  
ADC  
REMOTE SENSOR  
SIGNAL  
CONDITIONING  
FAN 2 ALARM  
SPEED REGISTER  
ANALOG  
MUX  
PWM  
CONTROLLER  
DRIVE2  
D1+/GPIO4  
D1–/GPIO3  
BANDGAP  
REFERENCE  
FAN 2 HOT-PLUG  
SPEED REGISTER  
TMIN/INSTALL  
BANDGAP  
TEMP SENSOR  
ADD  
GND  
*Protected by U.S. Patent Numbers 6,255,973 and 6,188,189  
Publication Order Number:  
©2009 SCILLC. All rights reserved.  
ADM1029/D  
January 2009 - Rev. 1  
ADM1029–SPECIFICATIONS1, 2  
(TA = TMIN to TMAX, VCC = VMIN to VMAX, unless otherwise noted.)  
Parameter  
Min  
Typ  
Max  
Unit  
Test Conditions/Comments  
POWER SUPPLY  
Supply Voltage, VCC  
Supply Current, ICC  
3.0  
3.30  
1.7  
1.5  
10  
5.5  
3.0  
V
mA  
mA  
µA  
Interface Inactive, ADC Active  
ADC Inactive, DAC Active  
Shutdown Mode  
60  
TEMPERATURE-TO-DIGITAL CONVERTER  
Internal Sensor Accuracy  
Resolution  
1
1
3
5
°C  
°C  
°C  
°C  
µA  
µA  
External Diode Sensor Accuracy  
Resolution  
3
0°C TA 100°C  
1
Remote Sensor Source Current  
90  
5.5  
High Level  
Low Level  
ANALOG-TO-DIGITAL CONVERTER  
Total Unadjusted Error, TUE  
Differential Nonlinearity, DNL  
Power Supply Sensitivity  
1
1
%
Note 3  
LSB  
%/ V  
1
Conversion Time  
Analog Input or Internal Temperature  
External Temperature  
11.6  
ms  
ms  
185.6  
FAN RPM-TO-DIGITAL CONVERTER  
Accuracy  
6
%
60°C TA 100°C: VCC = 3.3 V  
Full-Scale Count  
FAN 1 and FAN 2 Nominal Input RPM4  
255  
8800  
4400  
2200  
1100  
60.0  
rpm  
rpm  
rpm  
rpm  
kHz  
Divisor = 1, Fan Count = 153  
Divisor = 2, Fan Count = 153  
Divisor = 4, Fan Count = 153  
Divisor = 8, Fan Count = 153  
Internal Clock Frequency  
56.4  
63.6  
OPEN-DRAIN DIGITAL OUTPUTS (INT, CFAULT)  
Output Low Voltage, VOL  
0.4  
1
V
IOUT = –6.0 mA, VCC = 3 V  
VOUT = VCC  
High Level Output Current, IOH  
0.1  
0.1  
µA  
OPEN-DRAIN SERIAL DATA BUS OUTPUT (SDA)  
Output Low Voltage, VOL  
0.4  
1
V
IOUT = –6.0 mA, VCC = 3 V  
VOUT = VCC  
High Level Output Leakage Current, IOH  
µA  
SERIAL BUS DIGITAL INPUTS (SCL, SDA)  
Input High Voltage, VIH  
Input Low Voltage, VIL  
2.1  
V
0.8  
V
Hysteresis  
500  
mV  
DIGITAL INPUT LOGIC LEVELS RESET,  
GPIO1-6, FAULT1/2, TACH1/2, PRESENT1/2  
Input High Voltage, VIH  
2.1  
–1  
V
V
Input Low Voltage, VIL  
0.8  
+1  
DIGITAL INPUT CURRENT  
Input High Current, IIH  
Input Low Current, IIL  
µA  
µA  
pF  
VIN = VCC  
VIN = 0  
Input Capacitance, CIN  
20  
50  
SERIAL BUS TIMING5  
Clock Frequency, fSCLK  
Glitch Immunity, tSW  
10  
100  
kHz  
ns  
µs  
See Figure 1  
See Figure 1  
See Figure 1  
See Figure 1  
See Figure 1  
See Figure 1  
Bus Free Time, tBUF  
4.7  
4.7  
4
Start Setup Time, tSU:STA  
Start Hold Time, tHD:STA  
Stop Condition Setup Time, tSU:STO  
µs  
µs  
4
µs  
Rev. 1 | Page 2 of 50 | www.onsemi.com  
ADM1029  
Parameter  
Min  
Typ  
Max  
Unit  
Test Conditions/Comments  
SERIAL BUS TIMING5 (continued)  
SCL Low Time, tLOW  
1.3  
4
µs  
µs  
ns  
ns  
ns  
ns  
See Figure 1  
See Figure 1  
See Figure 1  
See Figure 1  
See Figure 1  
See Figure 1  
SCL High Time, tHIGH  
50  
SCL, SDA Rise Time, tR  
SCL, SDA Fall Time, tF  
Data Setup Time, tSU:DAT  
Data Hold Time, tHD:DAT  
1000  
300  
250  
300  
NOTES  
1All voltages are measured with respect to GND, unless otherwise specified.  
2Typicals are at TA = 25°C and represent most likely parametric norm. Shutdown current typ is measured with VCC = 3.3 V.  
3TUE (Total Unadjusted Error) includes Offset, Gain, and Linearity errors of the ADC, multiplexer.  
4The total fan count is based on two pulses per revolution of the fan tachometer output.  
5Timing specifications are tested at logic levels of VIL = 0.8 V for a falling edge and VIH = 2.1 V for a rising edge.  
Specifications subject to change without notice.  
PIN CONFIGURATION  
ABSOLUTE MAXIMUM RATINGS*  
Positive Supply Voltage (VCC) . . . . . . . . . . . . . . . . . . . . . 6.5 V  
Voltage on Pins 13–18 . . . . . . . . . . . . –0.3 V to (VCC + 0.3 V)  
Voltage on Any Other Input or Output Pin . . . . –0.3 V to +6.5 V  
DRIVE1  
1
2
24 DRIVE2  
23  
FAULT1  
FAULT2  
Input Current at Any Pin . . . . . . . . . . . . . . . . . . . . . . .  
Package Input Current . . . . . . . . . . . . . . . . . . . . . . .  
5 mA  
20 mA  
3
22  
21  
20  
19  
18  
17  
16  
15  
14  
13  
TACH1  
TACH2  
Maximum Junction Temperature (TJ max) . . . . . . . . . . 150°C  
Storage Temperature Range . . . . . . . . . . . . –65°C to +150°C  
Lead Temperature  
4
PRESENT1  
SCL  
PRESENT2  
AIN1/GPIO1  
AIN0/GPIO0  
TMIN/INSTALL  
D2+/GPIO6  
D2/GPIO5  
ADD  
5
Vapor Phase (60 sec) . . . . . . . . . . . . . . . . . . . . . . . . . 215°C  
Infrared (15 sec) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200°C  
ESD Rating All Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . 2000 V  
6
SDA  
ADM1029  
TOP VIEW  
(Not To Scale)  
7
GND  
8
V
CC  
*Stresses above those listed under Absolute Maximum Ratings may cause perma-  
nent damage to the device. This is a stress rating only; functional operation of the  
device at these or any other conditions above those indicated in the operational  
section of this specification is not implied. Exposure to absolute maximum rating  
conditions for extended periods may affect device reliability.  
9
CFAULT  
INT  
10  
11  
12  
GPIO2  
D1+/GPIO4  
D2/GPIO3  
THERMAL CHARACTERISTICS  
RESET  
24-Lead QSOP Package:  
JA = 105°C/W, θJC = 39°C/W  
θ
tR  
tF  
tHD;STA  
tLOW  
SCL  
SDA  
tSU;STO  
tHIGH  
tSU;STA  
tHD;STA  
tHD;DAT  
tSU;DAT  
tBUF  
S
P
S
P
Figure 1. Diagram for Serial Bus Timing  
Rev. 1 | Page 3 of 50 | www.onsemi.com  
ADM1029  
PIN FUNCTION DESCRIPTIONS  
Description  
Pin No.  
Mnemonic  
1
DRIVE1  
Open Drain Digital Output. Pulsewidth Modulated (PWM) output to control the speed of  
Fan 1. Requires 10 ktypical pull-up resistor.  
2
3
4
FAULT1  
TACH1  
Open Drain Digital I/O. When used with a fan having a fault output, a Logic 0 input to this pin  
signals a fault on Fan 1. Also used as a fault output.  
Open Drain Digital Input. Digital fan tachometer input for Fan 1. Will accept logic signals up  
to 5 V even when VCC is lower than 5 V.  
PRESENT1  
Open Drain Digital Input. A shorting link in the fan connector holds this pin low when  
Fan 1 is connected.  
5
6
7
8
SCL  
SDA  
GND  
VCC  
Open Drain Digital Input. Serial Bus Clock. Requires 2.2 kpull-up typical.  
Digital I/O. Serial Bus bidirectional data. Open-drain output requires 2.2 kpull-up.  
System Ground  
Power (3.0 V to 5.5 V). Typically powered from 3.3 V power rail. Bypass with the parallel  
combination of 10 µF (electrolytic or tantalum) and 0.1 µF (ceramic) bypass capacitors.  
9
CFAULT  
INT  
Open Drain Digital I/O. Cascade fault input/output used for fault signaling between  
multiple ADM1029s.  
10  
Digital Output. Interrupt Request (Open Drain). The output is enabled when Bit 1 of the  
Configuration Register is set to 0. The default state is enabled.  
11  
12  
13  
GPIO2  
Open Drain Digital I/O. General-purpose logic I/O pin.  
Open Drain Digital Input. Active low reset input.  
RESET  
D1–/GPIO3  
Analog Input/Open Drain Digital I/O. Connected to cathode of external temperature-sensing  
diode, or may be reconfigured as a general-purpose logic input/output.  
14  
D1+/GPIO4  
Analog Input/Open Drain Digital I/O. Connected to anode of external temperature-sensing  
diode, or may be reconfigured as a general-purpose logic input/output.  
15  
16  
ADD  
Eight-Level Analog Input. Used to set the three LSBs of the serial bus address.  
D2–/GPIO5  
Analog Input/Open Drain Digital I/O. Connected to cathode of external temperature-sensing  
diode, or may be reconfigured as a general-purpose logic input/output.  
17  
18  
D2+/GPIO6  
Analog Input/Open Drain Digital I/O. Connected to anode of external temperature-sensing  
diode, or may be reconfigured as a general-purpose logic input/output.  
TMIN/INSTALL  
Eight-Level Analog Input. The voltage on this pin defines whether automatic fan speed control  
is enabled, the minimum temperature at which the fan(s) will turn on in automatic speed con-  
trol mode, and the number of fans that should be installed.  
19  
20  
21  
22  
23  
24  
AIN0/GPIO0  
AIN1/GPIO1  
PRESENT2  
TACH2  
Analog Input/Open Drain Digital I/O. May be configured as a 0 V to 2.5 V analog input or as a  
general-purpose digital I/O pin.  
Analog Input/Open Drain Digital I/O. May be configured as a 0 V to 2.5 V analog input or as a  
general-purpose digital I/O pin.  
Open Drain Digital Input. A shorting link in the fan connector holds this pin low when Fan 2  
is connected.  
Open Drain Digital Input. Digital fan tachometer input for Fan 2. Will accept logic signals up  
to 5 V even when VCC is lower than 5 V.  
FAULT2  
Open Drain Digital I/O. When used with a fan having a fault output, a Logic 0 input to this pin  
signals a fault on Fan 2. Also used as a fault output.  
DRIVE2  
Open Drain Digital Output. Pulsewidth Modulated (PWM) output to control the speed of  
Fan 2. Requires 10 ktypical pull-up resistor.  
Rev. 1 | Page 4 of 50 | www.onsemi.com  
Typical Performance Characteristics–ADM1029  
110  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
15  
10  
5
DXP TO GND  
0
DXP TO V (3.3V)  
CC  
5  
10  
15  
20  
0
10  
20  
30  
40  
50 60  
70  
80  
90 100 110  
0
3.3  
10  
30  
100  
LEAKAGE RESISTANCE M  
MEASURED TEMPERATURE  
TPC 1. Remote Temperature Error vs. PC Board Track  
Resistance  
TPC 4. Pentium® III Temperature Measurement vs.  
ADM1029 Reading  
1
0
4.5  
4.0  
1  
V
= 250mV p-p  
IN  
2  
3.5  
3.0  
2.5  
2.0  
1.5  
1.0  
0.5  
0
3  
4  
5  
6  
7  
8  
9  
10  
11  
12  
13  
14  
15  
16  
V
= 100mV p-p  
IN  
0.5  
1.0  
0
1
4
8
12 16 20 50 100 200 300  
500  
400 600  
1.0  
2.2  
3.3  
4.7  
10.0  
22.0  
47.0  
FREQUENCY MHz  
DXP DXN CAPACITANCE nF  
TPC 2. Remote Temperature Error vs. Power Supply  
Noise Frequency  
TPC 5. Remote Temperature Error vs. Capacitance  
Between D+ and D–  
10  
9
80  
70  
60  
50  
40  
30  
20  
10  
0
V
= 5V  
CC  
V
V
V
= 100mV p-p  
= 60mV p-p  
= 40mV p-p  
8
7
IN  
IN  
IN  
6
5
4
3
2
V
= 3.3V  
CC  
1
0
1  
0
1
5
10  
25  
50  
75 100 250 500 750 1000  
0
0.4 0.8 10 50 100 150 200 250 300 350 400 450 500 550 600  
FREQUENCY MHz  
SCLK FREQUENCY kHz  
TPC 3. Remote Temperature Error vs. Common-Mode  
Noise Frequency  
TPC 6. Standby Current vs. Clock Frequency  
TPC = Typical Performance Characteristics Figure  
Rev. 1 | Page 5 of 50 | www.onsemi.com  
ADM1029  
13  
12  
11  
10  
9
10  
9
8
V
= 40mV p-p  
V
= 250mV p-p  
IN  
IN  
7
8
6
V
= 30mV p-p  
IN  
V
= 100mV p-p  
IN  
7
V
= 20mV p-p  
5
IN  
6
4
5
4
3
3
2
2
1
1
0
0
1  
1  
0
1
4
8
12 16 20 50 100  
200  
300  
400  
500  
600  
0
1
4
8
12 16 20 50 100 200 300 400 500 600  
FREQUENCY MHz  
FREQUENCY MHz  
TPC 7. Remote Temperature Error vs. Differential-Mode  
Noise Frequency  
TPC 10. Local Sensor Temperature Error vs. Power Supply  
Noise Frequency  
120  
110  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
32  
30  
28  
26  
24  
22  
20  
18  
16  
14  
12  
10  
8
6
4
2
0
1.0  
0
1
2
3
4
5
6
7
8
9
10  
1.4  
1.8  
2.2  
2.6  
3.0  
3.4  
3.8  
4.2  
4.6  
TIME Seconds  
SUPPLY VOLTAGE V  
TPC 8. Standby Supply Current vs. Supply Voltage  
TPC 11. ADM1029 Response to Thermal Shock  
0.10  
0.00  
1.80  
1.75  
1.70  
1.65  
1.60  
1.55  
1.50  
1.45  
1.40  
1.35  
1.30  
1.25  
1.20  
1.15  
1.10  
1.05  
0.10  
0.20  
0.30  
0.40  
0.50  
0.60  
0.70  
0.80  
0.90  
1.00  
1.10  
1.20  
1.00  
0
20  
40  
60  
80  
85  
100  
105 120  
2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 4.0 4.2 4.4 4.6 4.8 5.0  
TEMPERATURE ؇C  
SUPPLY VOLTAGE V  
TPC 9. Supply Current vs. Supply Voltage  
TPC 12. Remote Temperature Error  
TPC = Typical Performance Characteristics Figure  
Rev. 1 | Page 6 of 50 | www.onsemi.com  
ADM1029  
0.05  
0.00  
FUNCTIONAL DESCRIPTION  
SERIAL BUS INTERFACE  
0.05  
0.10  
0.15  
0.20  
0.25  
0.30  
0.35  
0.40  
0.45  
0.50  
0.55  
Control of the ADM1029 is carried out via the serial bus. The  
ADM1029 is connected to this bus as a slave device, under the  
control of a master device.  
The ADM1029 has a 7-bit serial bus address. The four MSBs of  
the address are set to 0101. The three LSBs can be set by the  
user to give a total of eight different addresses, allowing up to  
eight ADM1029s to be connected to a single serial bus segment.  
To minimize device pin count and size, the three LSBs are set  
using a single pin (ADD, Pin 15). This is an 8-level input whose  
input voltage is set by a potential divider. The voltage on ADD  
is sampled immediately after power-up and digitized by the  
on-chip ADC to determine the value of the 3 LSBs. Since ADD  
is sampled only at power-up, any changes made while power is  
on will have no effect.  
0.60  
0
20  
40  
60  
80  
85  
100  
105  
120  
TEMPERATURE ؇C  
TPC 13. Local Temperature Error  
PRODUCT DESCRIPTION  
V
CC  
R1  
ADD  
The ADM1029 is a versatile fan controller and monitor for use  
in personal computers, servers, telecommunications equipment,  
or any high-availability system where reliable control and moni-  
toring of multiple cooling fans is required. Each ADM1029 can  
control the speed of one or two fans and can measure the speed  
of fans that have a tachometer output. The ADM1029 can also  
measure the temperature of one or two external sensing diodes  
or an internal temperature sensor, allowing fan speed to be  
adjusted to keep system temperature within acceptable limits. The  
ADM1029 has FAULT inputs for use with fans that can signal  
failure conditions, and inputs to detect whether or not fans are  
connected.  
ADM1029  
R2  
GND  
Figure 2. Setting the Serial Address  
Table I shows resistor values for setting the 3 LSBs of the serial  
bus address. The same principle is used to set the voltage on Pin  
18 (TMIN/INSTALL), which controls the automatic fan speed  
control function, and also tells the ADM1029 how many fans  
should be installed, as described later.  
If several ADM1029s are used in a system, their ADD inputs  
can tap off a single potential divider, as shown in Figure 3.  
The ADM1029 communicates with the host processor over an  
System Management (SMBus) serial bus. It supports eight  
different serial bus addresses, so that up to eight devices can  
be connected to a common bus, controlling up to sixteen fans.  
This makes software support and hardware design scalable.  
V
CC  
ADD  
ADDRESS XXXX111  
ADM1029 #1  
1.5k  
ADD  
ADDRESS XXXX110  
1k⍀  
ADM1029 #2  
ADM1029 #3  
ADM1029 #4  
ADM1029 #5  
ADM1029 #6  
ADM1029 #7  
ADD  
ADD  
The ADM1029 has an interrupt output (INT) that allows it  
to signal fault conditions to the host processor. It also has a  
separate, cascadable fault output (CFAULT) that allows the  
ADM1029 to signal a fault condition to other ADM1029s.  
ADDRESS XXXX101  
1k⍀  
ADDRESS XXXX100  
1k⍀  
ADDRESS XXXX011  
1k⍀  
ADD  
ADD  
ADD  
The ADM1029 has a number of useful features including an  
automatic fan speed control option implemented in hardware  
with no software requirement, automatic use of backup fans in  
the event of fan failure, and supports hot-swapping of failed fans.  
ADDRESS XXXX010  
1k⍀  
ADDRESS XXXX001  
1.5k⍀  
ADD  
ADDRESS XXXX000  
GND  
ADM1029 #8  
Figure 3. Setting Address of up to Eight ADM1029s  
Rev. 1 | Page 7 of 50 | www.onsemi.com  
ADM1029  
Table I. Resistor Ratios for Setting Serial Bus Address  
3 MSBs  
of ADC  
Ideal Ratio  
R2/(R1 + R2)  
R1  
(k)  
R2  
(k)  
Actual  
R2/(R1 + R2)  
Error  
%
Address  
111  
110  
101  
100  
011  
010  
001  
000  
N/A  
0
1
0
0101111  
0101110  
0101101  
0101100  
0101011  
0101010  
0101001  
0101000  
0.8125  
0.6875  
0.5625  
0.4375  
0.3125  
0.1875  
N/A  
18  
22  
12  
15  
47  
82  
82  
47  
15  
12  
22  
18  
0
0.82  
+0.75  
–0.63  
–0.69  
+0.69  
+0.63  
–0.75  
0
0.6812  
0.5556  
0.4444  
0.3188  
0.18  
0
The serial bus protocol operates as follows:  
occur during the low period of the clock signal and remain  
stable during the high period, as a low-to-high transition  
when the clock is high may be interpreted as a STOP signal.  
The number of data bytes that can be transmitted over the  
serial bus in a single READ or WRITE operation is limited  
only by what the master and slave devices can handle.  
1. The master initiates data transfer by establishing a START  
condition, defined as a high-to-low transition on the serial  
data line SDA, while the serial clock line SCL remains high.  
This indicates that an address/data stream will follow. All  
slave peripherals connected to the serial bus respond to the  
START condition, and shift in the next eight bits, consisting  
of a 7-bit address (MSB first) plus an R/W bit, which deter-  
mines the direction of the data transfer, i.e., whether data  
will be written to or read from the slave device.  
3. When all data bytes have been read or written, stop condi-  
tions are established. In WRITE mode, the master will pull  
the data line high during the tenth clock pulse to assert a  
STOP condition. In READ mode, the master device will  
override the acknowledge bit by pulling the data line high  
during the low period before the ninth clock pulse. This is  
known as No Acknowledge. The master will then take the  
data line low during the low period before the tenth clock  
pulse, high during the tenth clock pulse to assert a STOP  
condition.  
The peripheral whose address corresponds to the transmitted  
address responds by pulling the data line low during the low  
period before the ninth clock pulse, known as the Acknowl-  
edge Bit. All other devices on the bus now remain idle while  
the selected device waits for data to be read from or written  
to it. If the R/W bit is a 0, the master will write to the slave  
device. If the R/W bit is a 1 the master will read from the  
slave device.  
Any number of bytes of data may be transferred over the serial  
bus in one operation, but it is not possible to mix read and write  
in one operation, because the type of operation is determined at  
the beginning and cannot subsequently be changed without  
starting a new operation.  
2. Data is sent over the serial bus in sequences of nine clock  
pulses, eight bits of data followed by an acknowledge bit  
from the slave device. Transitions on the data line must  
Rev. 1 | Page 8 of 50 | www.onsemi.com  
ADM1029  
1
0
9
1
9
SCL  
D6  
1
0
A2  
A0  
D4  
D3  
D2  
D1  
SDA  
1
A1  
D7  
D5  
D0  
R/W  
START BY  
MASTER  
ACK. BY  
ADM1029  
ACK. BY  
ADM1029  
FRAME 2  
ADDRESS POINTER REGISTER BYTE  
FRAME 1  
SERIAL BUS ADDRESS BYTE  
1
9
SCL (CONTINUED)  
SDA (CONTINUED)  
D4  
D3  
D2  
D1  
D7  
D6  
D5  
D0  
ACK. BY  
ADM1029  
STOP BY  
MASTER  
FRAME 3  
DATA BYTE  
Figure 4a. Writing a Register Address to the Address Pointer Register, then Writing Data to the Selected Register  
1
9
1
9
SCL  
D6  
0
1
0
A2  
A0  
D7  
D4  
D3  
D2  
D1  
SDA  
1
A1  
D5  
D0  
R/W  
START BY  
MASTER  
ACK. BY  
ADM1029  
ACK. BY  
ADM1029  
STOP BY  
MASTER  
FRAME 1  
SERIAL BUS ADDRESS BYTE  
FRAME 2  
ADDRESS POINTER REGISTER BYTE  
Figure 4b. Writing to the Address Pointer Register Only  
1
0
9
1
9
SCL  
D6  
D5  
D0  
1
0
A2  
A0  
D7  
D4  
D3  
D2  
D1  
SDA  
1
A1  
R/W  
START BY  
MASTER  
ACK. BY  
ADM1029  
NO ACK. STOP BY  
BY MASTER MASTER  
FRAME 1  
SERIAL BUS ADDRESS BYTE  
FRAME 2  
DATA BYTE FROM ADM1029  
Figure 4c. Reading Data from a Previously Selected Register  
Rev. 1 | Page 9 of 50 | www.onsemi.com  
ADM1029  
After sending its slave address, the first device will then clear its  
INT output. The host can then check if the INT is still low and  
send the general call again if necessary until all devices asserting  
INT have responded.  
In the case of the ADM1029, write operations contain either  
one or two bytes, and read operations contain one byte, and  
perform the following functions:  
To write data to one of the device data registers or read data  
from it, the Address Pointer Register must be set so that the  
correct data register is addressed, data can be written into that  
register or read from it. The first byte of a write operation always  
contains an address that is stored in the Address Pointer Regis-  
ter. If data is to be written to the device, the write operation  
contains a second data byte that is written to the register  
selected by the address pointer register.  
The ARA function can be disabled by setting Bit 2 of the Con-  
figuration Register (address 01h).  
TEMPERATURE MEASUREMENT SYSTEM  
LOCAL TEMPERATURE MEASUREMENT  
The ADM1029 contains an on-chip bandgap temperature sensor,  
whose output is digitized by the on-chip ADC. The temperature  
data is stored in the Local Temp Value Register (address A0h).  
As both positive and negative temperatures can be measured, the  
temperature data is stored in two’s complement format, as shown  
in Table II. Theoretically, the temperature sensor and ADC can  
measure temperatures from –128°C to +127°C with a resolution  
of 1°C, but temperatures outside the operating temperature  
range of the device cannot be measured by the internal sensor.  
This is illustrated in Figure 4a. The device address is sent over  
the bus followed by R/W set to 0. This is followed by two data  
bytes. The first data byte is the address of the internal data  
register to be written to, which is stored in the Address Pointer  
Register. The second data byte is the data to be written to the  
internal data register.  
When reading data from a register there are two possibilities:  
REMOTE TEMPERATURE MEASUREMENT  
1. If the ADM1029’s Address Pointer Register value is unknown  
or not the desired value, it is first necessary to set it to the  
correct value before data can be read from the desired data  
register. This is done by performing a write to the ADM1029  
as before, but only the data byte containing the register address  
is sent, as data is not to be written to the register. This is  
shown in Figure 4b.  
The ADM1029 can measure the temperature of one or two  
remote diode-connected transistors, connected to Pins 13 and  
14 and/or 16 and 17. The data from the temperature measure-  
ments is stored in the Remote 1 and Remote 2 Temp Value  
Registers (addresses A1h and A2h).  
If two remote temperature measurements are not required, Pins  
16 and 17 can be reconfigured as general-purpose logic I/O  
pins, as explained later.  
A read operation is then performed consisting of the serial  
bus address, R/W bit set to 1, followed by the data byte read  
from the data register. This is shown in Figure 4c.  
The forward voltage of a diode or diode-connected transistor,  
operated at a constant current, exhibits a negative temperature  
coefficient of about –2 mV/°C. The absolute value of VBE varies  
from device to device and individual calibration is required to  
null this out so, unfortunately, the technique is unsuitable for  
mass production.  
2. If the Address Pointer Register is known to be already at the  
desired address, data can be read from the corresponding  
data register without first writing to the Address Pointer  
Register, so Figure 4b can be omitted.  
Note: although it is possible to read a data byte from a data  
register without first writing to the Address Pointer Register,  
if the Address Pointer Register is already at the correct value,  
it is not possible to write data to a register without writing to  
the Address Pointer Register, because the first data byte of a  
write is always written to the Address Pointer Register.  
The technique used in the ADM1029 is to measure the change  
in VBE when the device is operated at two different currents.  
This is given by:  
VBE = KT/q × ln(N)  
where:  
ALERT RESPONSE ADDRESS  
K is Boltzmann’s constant  
q is charge on the carrier  
The ADM1029 has an interrupt (INT) output that is asserted  
low when a fault condition occurs. Several INT outputs can be  
wire OR’d to a common interrupt line. When the host processor  
receives an interrupt request, it would normally need to read the  
interrupt status register of each device to identify which device  
had made the interrupt request. However, the ADM1029 sup-  
ports the optional Alert Response Address function of the SMBus  
protocol. When the host processor receives an interrupt request  
it can send a general call address (0001100) over the bus. The  
device asserting INT will then send its own slave address back  
to the host processor, so the device asserting INT can be identi-  
fied immediately.  
T is absolute temperature in Kelvins  
N is ratio of the two currents  
Figure 5 shows the input signal conditioning used to measure  
the output of a remote temperature sensor. This figure shows  
the external sensor as a substrate transistor, provided for tem-  
perature monitoring on some microprocessors, but it could equally  
well be a discrete transistor.  
If a discrete transistor is used, the collector will not be grounded,  
and should be linked to the base. If a PNP transistor is used, the  
base is connected to the D– input and the emitter to the D+  
input. If an NPN transistor is used, the emitter is connected to  
the D– input and the base to the D+ input.  
If more than one device is asserting INT, all devices will try to  
respond with their slave address, but an arbitration process  
ensures that only the lowest address will be received by the host.  
Rev. 1 | Page 10 of 50 | www.onsemi.com  
ADM1029  
V
DD  
I
I
N 
؋
 I  
BIAS  
V
+
OUT  
D+  
TO ADC  
REMOTE  
SENSING  
D–  
TRANSISTOR  
V
OUT  
BIAS  
DIODE  
LOW-PASS FILTER  
fC = 65kHz  
Figure 5. Signal Conditioning for Remote Diode Temperature Sensors  
TEMPERATURE LIMITS  
To prevent ground noise interfering with the measurement, the  
more negative terminal of the sensor is not referenced to ground,  
but biased above ground by an internal diode at the D– input. If  
the sensor is used in a noisy environment, a capacitor of value  
up to 1000 pF may be placed between the D+/D– pins.  
The contents of the Local and Remote Temperature Value Regis-  
ters (addresses A0h to A2h) are compared to the contents of the  
High and Low Limit Registers at addresses 90h to 92h and 98h  
to 9Ah. How the ADM1029 responds to overtemperature/  
undertemperature conditions depends on the status of the Tem-  
perature Fault Action Registers (addresses 40h to 42h). The  
response of CFAULT, INT, and fan-speed-to-temperature events  
depends on the setting of these registers, as explained later.  
To measure VBE, the sensor is switched between operating currents  
of I and N × I. The resulting waveform is passed through a 65 kHz  
low-pass filter to remove noise, and to a chopper-stabilized amplifier  
that performs the functions of amplification and rectification of  
the waveform to produce a dc voltage proportional to VBE. This  
voltage is measured by the ADC to give a temperature output in  
8-bit two’s complement format. To further reduce the effects of  
noise, digital filtering is performed by averaging the results of 16  
measurement cycles. An external temperature measurement takes  
nominally 9.6 ms.  
Table II. Temperature Data Format  
Temperature  
Digital Output  
–128°C  
–125°C  
–100°C  
–75°C  
–50°C  
–25°C  
0°C  
1000 0000  
1000 0011  
1001 1100  
1011 0101  
1100 1110  
1110 0111  
0000 0000  
0000 1010  
0001 1001  
0011 0010  
0100 1011  
0110 0100  
0111 1101  
0111 1111  
The results of external temperature measurements are stored in  
8-bit, two’s complement format, as illustrated in Table II.  
OFFSET REGISTERS  
+10°C  
+25°C  
+50°C  
+75°C  
+100°C  
+125°C  
+127°C  
Digital noise and other error sources can cause offset errors in  
the temperature measurement, particularly on the remote sen-  
sors. The ADM1029 offers a way to minimize these effects. The  
offsets on the three temperature channels can be measured during  
system characterization and stored as two’s complement values  
in three offset registers at addresses 30h to 32h. The offset  
values are automatically added to, or subtracted from, the tem-  
perature values, depending on whether the two’s complement  
number corresponds to a positive or negative offset. Offset val-  
ues from –15°C to +15°C are allowed.  
The default value in the offset registers is zero, so if no offsets  
are programmed, the temperature measurements are unaltered.  
Rev. 1 | Page 11 of 50 | www.onsemi.com  
ADM1029  
LAYOUT CONSIDERATIONS  
Table III. Temperature-Specific Registers  
Digital boards can be electrically noisy environments, and care  
must be taken to protect the analog inputs from noise, particu-  
larly when measuring the very small voltages from a remote diode  
sensor. The following precautions should be taken:  
Address  
Description  
0x06  
0x30  
0x31  
0x32  
0x40  
0x41  
0x42  
0x48  
0x49  
0x4A  
0x80  
0x81  
0x82  
0x88  
0x89  
0x8A  
0x90  
0x91  
0x92  
0x98  
0x99  
0x9A  
0xA0  
0xA1  
0xA2  
Temp Devices Installed  
Local Temp Offset  
Remote 1 Temp Offset  
Remote 2 Temp Offset  
1. Place the ADM1029 as close as possible to the remote sens-  
ing diode. Provided that the worst noise sources such as  
clock generators, data/address buses, and CRTs are avoided,  
this distance can be 4 to 8 inches.  
Local Temp Fault Action  
Remote 1 Temp Fault Action  
Remote 2 Temp Fault Action  
Local Temp Cooling Action  
Remote 1 Temp Cooling Action  
Remote 2 Temp Cooling Action  
Local Temp TMIN  
2. Route the D+ and D– tracks close together, in parallel, with  
grounded guard tracks on each side. Provide a ground plane  
under the tracks if possible.  
3. Use wide tracks to minimize inductance and reduce noise  
pickup. Ten mil track minimum width and spacing is  
recommended.  
Remote 1 Temp TMIN  
Remote 2 Temp TMIN  
Local Temp TRANGE/THYST  
Remote 1 Temp TRANGE/THYST  
Remote 2 Temp TRANGE/THYST  
Local Temp High Limit  
Remote 1 Temp High Limit  
Remote 2 Temp High Limit  
Local Temp Low Limit  
GND  
D+  
10MIL  
10MIL  
10MIL  
10MIL  
10MIL  
10MIL  
10MIL  
D  
Remote 1 Temp Low Limit  
Remote 2 Temp Low Limit  
Local Temp Value  
GND  
Remote 1 Temp Value  
Remote 2 Temp Value  
Figure 6. Arrangement of Signal Tracks  
4. Try to minimize the number of copper/solder joints, which  
can cause thermocouple effects. Where copper/solder joints  
are used, make sure that they are in both the D+ and D–  
path and at the same temperature.  
The flowchart in Figure 7 shows how to configure the ADM1029  
to measure temperature. It also shows how to configure the  
ADM1029’s behavior for out-of-limit temperature measurements.  
FAN INTERFACING  
Thermocouple effects should not be a major problem as 1°C  
corresponds to about 240 µV, and thermocouple voltages are  
about 3 µV/oC of temperature difference. Unless there are two  
thermocouples with a big temperature differential between  
them, thermocouple voltages should be much less than 200 µV.  
The ADM1029 can be interfaced to many types of fan. It can be  
used to control the speed of a simple two-wire fan. It can mea-  
sure the speed of a fan with a tach output, and it can accept a  
logic input from fans with a FAULT output. By means of a  
shorting link in the fan connector it can also determine if a fan is  
present or not and if fans have been hot-swapped.  
5. Place 0.1 µF bypass and 1000 pF input filter capacitors close  
to the ADM1029.  
The ADM1029 can control or monitor one or two fans. Bits 0  
and 1 of the Fans Supported In System Register (03h) tell the  
ADM1029 how many fans it should be controlling/monitoring.  
6. If the distance to the remote sensor is more than 8 inches,  
the use of twisted pair cable is recommended. This will work  
up to about 6 to 12 feet.  
In the following descriptions “installed” means that the corre-  
sponding bit of register 03h is set and the ADM1029 expects to  
see a fan interfaced to it. It does not necessarily mean that the  
fan is actually, physically, connected.  
7. For really long distances (up to 100 feet), use shielded  
twisted pair such as Belden #8451 microphone cable. Con-  
nect the twisted pair to D+ and D– and the shield to GND  
close to the ADM1029. Leave the remote end of the shield  
unconnected to avoid ground loops.  
If a fan is installed, events such as a fault output and hot-swapping  
of the fan can cause INT and CFAULT to be asserted, unless  
they are masked for that particular event. If a fan is not installed,  
but is still physically connected to the ADM1029, these events will  
be ignored with respect to asserting INT or CFAULT, but will  
still be reflected in the corresponding Fan Status Register.  
Because the measurement technique uses switched current  
sources, excessive cable and/or filter capacitance can affect the  
measurement. When using long cables, the filter capacitor may  
be reduced or removed.  
Cable resistance can also introduce errors. 1 series resistance  
introduces about 0.5°C error.  
Setting Bit 0 indicates that Fan 1 is installed and is set to 1  
at power-up by default. Setting Bit 1 indicates that Fan 2 is  
installed and depends on the state of Pin 18 (TMIN/INSTALL)  
at power-up.  
TEMPERATURE-RELATED REGISTERS  
Table III is a list of registers on the ADM1029 that are specific  
to temperature measurement and control.  
Rev. 1 | Page 12 of 50 | www.onsemi.com  
ADM1029  
BIT 0 = 1  
BIT 1 = 1  
BIT 2 = 1  
BIT 3 = 0  
BIT 3 = 1  
BIT 4 = 1  
BIT 5 = 1  
BIT 6 = 1  
BIT 7  
ASSERT CFAULT ON OVER-TEMPERATURE  
RUN FAN(S) ALARM SPEED ON OVER-TEMPERATURE  
ASSERT INT ON OVER-TEMPERATURE  
CONFIGURE  
TEMPERATURE LOW  
LIMITS  
LOCAL (REG 0x98)  
REMOTE 1 (REG 0x99)  
REMOTE 2 (REG 0x9A)  
DEFAULTS  
LOCAL = 60؇C  
REMOTE 1 = 70؇C  
REMOTE 2 = 70؇C  
ALARM BELOW LOW TEMP LIMIT  
ALARM ABOVE LOW TEMP LIMIT  
ASSERT CFAULT WHEN LOW TEMP LIMIT CROSSED  
RUN FAN ALARM SPEED ON UNDER-TEMPERATURE  
ASSERT INT ON UNDER-TEMPERATURE  
LATCHES A TEMPERATURE OUT-OF-LIMIT EVENT  
7
6
5
4
3
2
1
0
CONFIGURE  
TEMPERATURE HIGH  
LIMITS  
DEFAULTS  
LOCAL = 80؇C  
LOCAL (REG 0x90)  
REMOTE 1 (REG 0x91)  
REMOTE 2 (REG 0x92)  
REMOTE 1 = 100؇C  
REMOTE 2 = 100؇C  
IS  
TEMPERATURE  
>
HIGH LIMIT?  
CONFIGURE  
TEMPERATURE FAULT  
ACTION  
LOCAL (REG 0x40)  
REMOTE 1 (REG 0x41)  
REMOTE 2 (REG 0x42)  
YES  
CFAULT  
IS  
TEMPERATURE  
>
HIGH LIMIT?  
YES  
FANS RUN  
ALARM SPEED  
CONFIGURE  
TEMPERATURE COOLING  
ACTION  
LOCAL (REG 0x48)  
REMOTE 1 (REG 0x49)  
REMOTE 2 (REG 0x4A)  
IS  
TEMPERATURE  
>
HIGH LIMIT?  
YES  
INT  
CONFIGURE  
TEMPERATURE OFFSETS  
LOCAL (REG 0x30)  
REMOTE 1 (REG 0x31)  
REMOTE 2 (REG 0x32)  
DEFAULTS  
LOCAL = 0؇C  
REMOTE 1 = 0؇C  
REMOTE 2 = 0؇C  
0 = ALARM BELOW TEMP LIMIT  
ALARM ABOVE OR  
BELOW LOW TEMP  
LIMIT?  
1 = ALARM ABOVE TEMP LIMIT  
CFAULT  
LOW TEMP LIMIT  
CROSSED?  
MEASURE  
TEMPERATURE  
YES  
LOCAL (REG 0xA0)  
REMOTE 1 (REG 0xA1)  
REMOTE 2 (REG 0xA2)  
LOW TEMP LIMIT  
CROSSED?  
YES  
FANS RUN ALARM SPEED  
LOW TEMP LIMIT  
CROSSED?  
YES  
INT  
AUTOMATIC FAN SPEED CONTROL (SEE TABLE X LATER)  
BIT 0 = 1  
BIT 1 = 1  
FAN 1 RUNS AT ALARM SPEED FOR OUT-OF-LIMIT TEMPERATURE EVENTS;  
OTHERWISE, FAN 1 RUNS AT SPEED DETERMINED BY AUTOMATIC FAN  
CONTROL.  
FAN 2 RUNS AT ALARM SPEED FOR OUT-OF-LIMIT TEMPERATURE EVENTS;  
OTHERWISE, FAN 2 RUNS AT SPEED DETERMINED BY AUTOMATIC FAN  
CONTROL.  
X
X
X
X
X
X
1
0
Figure 7. Temperature Sensing Flowchart  
Rev. 1 | Page 13 of 50 | www.onsemi.com  
ADM1029  
If two fans are installed, Bit 0 would be 1 by default and Pin  
18 would be tied high* to set Bit 1. If only one fan is installed, it  
would normally be Fan 1 and Pin 18 would be tied low* to  
clear Bit 1. However, both of these bits can be modified by  
writing to the register, so it is possible to have Fan 2 installed  
and not Fan 1, or even have no fans installed.  
After the speed of the first fan has been measured, the speed of  
the second fan (if installed) will be measured in the same way.  
The measurement cycle will repeat until monitoring is disabled.  
The fan speed measurements are stored in the Fan Tach Value  
registers at addresses 70h and 71h.  
If both fans are installed, Fan 1 will be measured first. If only  
one fan is installed, the ADM1029 will still try to measure  
both fans, starting with Fan 1, but the measurement on the  
noninstalled fan will time out when the Fan Tach Value count  
overranges.  
*Note that Pin 18 also sets TMIN for automatic fan speed control. If this function  
is used, Pin 18 would be set to some other level according to Table VIII.  
FAULT INPUTS/OUTPUTS  
The ADM1029 can be used with fans that have a fault output  
which indicates if the fan has stalled or failed. If one or both of  
the FAULT inputs (Pin 2 or Pin 23) goes low, both INT and  
CFAULT will be asserted.  
The fan speed count is given by:  
Count = f ϫ 4 ϫ 60/R/N  
where:  
Events on the fault inputs are also reflected in Bits 2 and 3 of the  
corresponding Fan Status Registers at addresses 10h and 11h.  
Bit 2 reflects the inverse state of the FAULT pin (0 if FAULT is  
high, 1 if FAULT is low), while Bit 3 is latched high if a FAULT  
input goes low. It must be cleared by writing a zero to it.  
f is oscillator frequency in Hz  
factor 4 is because 4 tach periods are counted  
factor 60 is to convert minutes to seconds  
R = fan speed in RPM  
N is number of tach pulses per revolution  
If the fan(s) being used do not have a FAULT output, the FAULT  
.
The frequency of the oscillator can be adjusted to suit the expected  
frequency range of the fan tach pulses, which depends on the  
fan speed and the number of tach pulses produced for each  
revolution of the fan, which is either 1, 2, or 4. The oscillator  
frequency is set by Bits 7 and 6 of the Fan Configuration Regis-  
ters (68h for Fan 1 and 69h for Fan 2).  
input(s) on the ADM1029 should be pulled high to VCC  
The FAULT pins can also be configured as open-drain outputs  
by setting Bit 5 of the corresponding Fan Fault Action Register  
(18h or 19h). If a FAULT pin is configured as an output, it will  
still function as an input. This means that when a fault input  
occurs it will be latched low by the fault output, even if the fault  
input is removed. The fault output can be used to drive a fan  
failure indicator such as an LED.  
Table III. Oscillator Frequencies  
Bit 7  
Bit 6  
Oscillator Frequency (Hz)  
If the FAULT pin is used as an output, any input to the FAULT  
pin should also be open-drain. This will avoid the fault input  
trying to source a high current into the FAULT pin if the fault  
input goes high while the fault output is low.  
0
0
1
1
0
1
0
1
Measurement Disabled  
470  
940  
1880  
FAN PRESENT INPUTS  
The fan PRESENT signal is implemented by a shorting link  
to ground in the fan connector. When the fan is plugged in,  
the corresponding PRESENT input (Pin 4 or Pin 21) on the  
ADM1029 is pulled low. If the fan is unplugged, the PRESENT  
input will be pulled high. INT and CFAULT will be asserted  
(unless masked) and the event will be reflected in Bits 0 and  
Bit 1 of the corresponding Fan Status Register.  
CLOCK  
CONFIG  
REG. BIT 4  
FAN 1  
TACH  
Appearance or disappearance of a PRESENT input signal dur-  
ing normal operation signals to the ADM1029 that a fan has  
been hot-plugged or unplugged. INT and CFAULT will be  
asserted (unless masked). When a fan is hot-plugged, Bit 7 of  
the corresponding Fan Status Register will be set and a Fan  
Free Wheel Test commences automatically.  
FAN 2  
TACH  
FAN 1  
MEASUREMENT  
PERIOD  
FAN 2  
MEASUREMENT  
PERIOD  
START OF  
MONITORING  
CYCLE  
Figure 8. Fan Speed Measurement  
FAN SPEED LIMITS  
FAN SPEED MEASUREMENT  
The fan counter does not count the fan tach output pulses  
directly, because at low fan speeds it would take several seconds  
to accumulate a reasonably large and accurate count. Instead,  
the period of the fan revolution is measured by gating an on-  
chip oscillator into the input of an 8-bit counter.  
Fans generally do not overspeed if run from the correct voltage,  
so the failure condition of interest is under-speed due to electri-  
cal or mechanical failure. For this reason only low-speed limits  
are programmed into the Tach Limit Registers for the fans.  
These registers are at address 78h for Fan 1 and 79h for Fan  
2. It should be noted that, since fan period rather than speed is  
being measured, the fan speed count will be larger the slower  
the fan speed. Therefore a fan failure fault will occur when the  
measurement exceeds the limit value.  
The fan speed measuring circuit is initialized on the first rising  
edge of a fan tach pulse after monitoring is enabled by setting  
Bit 4 of the Configuration Register. It then starts counting on  
the rising edge of the second tach pulse and counts for four fan  
tach periods, until the rising edge of the sixth tach pulse, or  
until the counter overranges if the fan tach period is too long.  
Rev. 1 | Page 14 of 50 | www.onsemi.com  
ADM1029  
V
For the most accurate fan failure indication, the oscillator  
frequency should be chosen to give as large a limit value as  
possible without the counter overranging. A count close to 3/4  
full-scale or 191 is the optimum value.  
12V  
CC  
PULL-UP  
4.7k  
TYP  
TACH  
TACH1  
OUTPUT OR TACH2  
FAN SPEED  
COUNTER  
For example, if a fan produces two tach pulses per revolution  
and the fan failure speed is to be 600 rpm, the oscillator fre-  
quency should be set to 940 Hz. This will give a count at the fail  
speed of:  
ZD1*  
ZENER  
*CHOOSE ZD1 VOLTAGE APPROX. 0.8 
؋
 V  
CC  
940 ϫ 4 ϫ 60/600/2 = 188  
Figure 9b. Fan with Tach. Pull-Up to Voltage >6.5 V (e.g.,  
12 V) Clamped with Zener Diode  
If the oscillator frequency were only 470 Hz, the count would  
be 94, while an oscillator frequency of 1880 Hz cannot be used  
because the count would be 376 and the counter would overrange.  
If the fan has a strong pull-up (less than 1 k) to 12 V, or a  
totem-pole output, a series resistor can be added to limit the  
Zener current, as shown in Figure 9c. Alternatively, a resistive  
attenuator may be used, as shown in Figure 9d.  
FAN MONITORING CYCLE TIME  
Five complete tach periods are required to carry out a fan speed  
measurement Therefore, if the start of a fan measurement just  
misses a rising edge, the measurement can take almost six tach  
periods for each fan.  
R1 and R2 should be chosen such that:  
2 V < VPULLUP × R2/(RPULLUP + R1 + R2) < 5 V  
The fan inputs have an input resistance of nominally 160 kto  
ground, so this should be taken into account when calculating  
resistor values.  
The worst-case monitoring cycle time is when both fans are  
under speed and the fan speed counter counts up to its maxi-  
mum value. The actual count takes 256 oscillator pulses over  
four tach periods, plus a further two tach periods or 128 oscilla-  
tor pulses before the count starts. The total monitoring cycle  
time is therefore:  
With a pull-up voltage of 12 V and pull-up resistor less than  
1 k, suitable values for R1 and R2 would be 100 kand 47 k.  
This will give a high input voltage of 3.83 V.  
V
12V  
CC  
tMEAS = 384/fOSC(FAN 1) + 384/fOSC(FAN 2)  
In order to read a valid result from the Fan Tach Value Registers,  
the total monitoring time allowed after starting the monitoring  
cycle should be greater than this.  
TACH  
O/P  
TACH1  
OR TACH2  
FAN SPEED  
COUNTER  
PULL-UP  
TYP <1k  
R1  
ZD1  
10k⍀  
ZENER*  
OR TOTEM-POLE  
TACH SIGNAL CONDITIONING  
Signal conditioning in the ADM1029 accommodates the slow  
rise and fall times typical of fan tachometer outputs. The maxi-  
mum input signal range is 0 V to 5 V, even if VCC is less than  
5 V. In the event that these inputs are supplied from fan outputs  
that exceed 0 V to 5 V, either resistive attenuation of the fan  
signal or diode clamping must be included to keep inputs within  
an acceptable range.  
*CHOOSE ZD1 VOLTAGE APPROX. 0.8 
؋
 V  
CC  
Figure 9c. Fan with Strong Tach. Pull-Up to >VCC or  
Totem-Pole Output, Clamped with Zener and Resistor  
12V  
V
CC  
Figures 9a to 9d show circuits for most common fan tach outputs.  
<1k  
TACH1  
OR TACH2  
R1*  
FAN SPEED  
COUNTER  
If the fan tach output has a resistive pull-up to VCC, it can be  
connected directly to the fan input, as shown in Figure 9a.  
TACH  
OUTPUT  
R2*  
12V  
V
CC  
*SEE TEXT  
Figure 9d. Fan with Strong Tach. Pull-Up to >VCC or  
Totem-Pole Output, Attenuated with R1/R2  
PULL-UP  
4.7k  
TYP  
TACH1  
OR TACH2  
FAN SPEED  
COUNTER  
TACH  
OUTPUT  
FAN SPEED CONTROL  
Fan speed is controlled using pulsewidth modulation (PWM).  
The PWM outputs (Pins 1 and 24) give a pulse output with a  
programmable frequency (default 250 Hz) and a duty-cycle  
defined by the contents of the relevant fan speed register, or by  
the automatic fan speed control when this mode is enabled. The  
speed at which a fan runs is determined by fault conditions and  
the settings of various control and mask registers.  
Figure 9a. Fan with Tach Pull-Up to +VCC  
If the fan output has a resistive pull-up to 12 V (or other voltage  
greater than 6.5 V), the fan output can be clamped with a Zener  
diode, as shown in Figure 9b. The Zener voltage should be  
chosen so that it is greater than VIH but less than 6.5 V, allowing  
for the voltage tolerance of the Zener. A value of between 3 V  
and 5 V is suitable.  
A fan can only be driven if it is defined as being supported by  
the controller in register 02h. The ADM1029 supports up to  
two fans, so Bits 0 and 1 of this register are permanently set.  
This register is read-only.  
Rev. 1 | Page 15 of 50 | www.onsemi.com  
ADM1029  
A fan will only be driven if it is defined as being supported by  
the system in register 03h. If Bit 0 of this register is set, it indi-  
cates that Fan 1 is installed. This is the power-on default. If  
Bit 1 is set, it indicates that Fan 2 is installed. This bit is set by  
the state of Pin 18 at power-up. This register is read/write and  
the default/power-on setting can be overwritten. If a fan is not  
supported in register 03h it will not be driven, even if it is physi-  
cally installed.  
If Bit 1 of an AIN Behavior Register is set (50h—AIN0,  
51h—AIN1), all fans controlled by the ADM1029 will go to  
alarm speed if the corresponding AIN high limit is exceeded.  
If Bit 5 of an AIN Behavior Register is set, all fans controlled  
by the ADM1029 will go to alarm speed if an analog input  
crosses the corresponding AIN low limit, the direction depend-  
ing on the setting of Bit 3 of the AIN control register. (0 =  
alarm when input goes below low limit, 1 = alarm when input  
goes above low limit).  
The PWM outputs are open-drain outputs. They require pull-up  
resistors and must be amplified and buffered to drive the fans.  
If a thermal override occurs while the ADM1029 is in sleep  
mode, all fans controlled by the ADM1029 will run at  
alarm speed.  
Minimum Speed  
The normal operating fan speed is set by the four LSBs of the  
Fan 1 and Fan 2 Minimum/Alarm Speed Registers (addresses  
60h, 61h). These bits also set the minimum speed at which a fan  
will run in automatic control mode. These bits should be set to  
05h. This corresponds to 33% PWM duty-cycle, which is the  
lowest speed at which most fans will run reliably.  
Hot-Plug Speed  
Hot-plug speed is set by the four LSBs of the Fan 1 and Fan 2  
Configuration Registers (addresses 68h and 69h). The PWM  
frequency is set by Bits 4 and 5 of these registers, while Bits 6  
and 7 set the number of pulses per revolution for fan speed  
measurement.  
Fan(s) will run at minimum speed if there is no fault condition,  
automatic fan speed is disabled, and there are no other over-  
riding conditions.  
Fan(s) will run at hot-plug speed if any of the following condi-  
tions occur, assuming the condition has not been masked using  
the Fan Event Mask Registers:  
Alarm Speed  
Alarm speed is set by the four MSBs of the Fan 1 and Fan 2  
Minimum/Alarm Speed Registers (addresses 60h, 61h). Fan(s)  
will run at alarm speed if any of the following conditions occurs,  
assuming the condition has not been masked out using the Fan  
Event Mask Registers:  
If a fan is unplugged, the other fan (if any) controlled by the  
ADM1029 will run at hot-plug speed.  
Setting Bit 0 of register 08h forces Fan 1 to run at hot-plug  
speed (Set Fan x Hot-Plug Speed).  
Setting Bit 1 of register 08h forces Fan 2 to run at hot-plug  
speed (Set Fan x Hot-Plug Speed).  
Setting Bit 0 of register 07h forces Fan 1 to run at alarm speed  
(Set Fan x Alarm Speed Register).  
When a GPIO pin is configured as an input by setting Bit 0 of  
the corresponding GPIO Behavior Register, and Bit 5 of the  
GPIO Behavior Register is also set, all fans controlled by the  
ADM1029 will go to hot-plug speed when the logic input is  
asserted (high or low, depending on the polarity bit, Bit 1 of  
the corresponding GPIO Behavior Register).  
Setting Bit 1 of register 07h forces Fan 2 to run at alarm speed  
(Set Fan x Alarm Speed Register).  
If monitoring is disabled by clearing Bit 4 of the Con-  
figuration Register, all fans controlled by the ADM1029  
will run at alarm speed.  
When a GPIO pin is configured as an input by setting Bit 0 of  
the corresponding GPIO Behavior Register, and Bit 4 of the  
GPIO Behavior Register is also set, all fans controlled by the  
ADM1029 will go to alarm speed when the logic input is  
asserted (high or low, depending on the polarity bit, Bit 1 of  
the corresponding GPIO Behavior Register).  
If Bit 6 of a Fan Fault Action Register is set (18h for Fan 1,  
19h for Fan 2) the corresponding fan will go to hot-plug speed  
when CFAULT is pulled low by an external source.  
Note: If operating conditions and register settings are such that  
both alarm speed and hot-plug speed would be triggered, which  
one takes priority is determined by Bit 5 of the Fan 1 and Fan 2  
Status Registers (addresses 10h and 11h). If this bit is set, hot-plug  
speed takes priority. If it is cleared, alarm speed takes priority.  
If Bit 7 of a Fan Fault Action Register is set (18h—Fan 1, 19h  
—Fan 2) the corresponding fan will go to alarm speed when  
CFAULT is pulled low by an external source.  
Full Speed  
If a tach measurement exceeds the set limit, all fans controlled  
by the ADM1029 will run at alarm speed.  
Fans will run at full speed if the corresponding bits in the Set  
Fan x Full Speed Register (address 09h) are set: Bit 0 for Fan 1  
and Bit 1 for Fan 2.  
If a fan fault input pin is asserted (low), all fans controlled by  
the ADM1029 will run at alarm speed.  
Fan Mask Registers  
If Bit 1 of a Temp. Fault Action Register is set (40h—Local  
Sensor, 41h—Remote 1, 42h—Remote 2), all fans controlled  
by the ADM1029 will go to alarm speed if the corresponding  
temperature high limit is exceeded.  
The effect of various conditions on fan speed can be enabled or  
disabled by mask registers. In all these registers, setting Bit 0 of  
the register enables Fan 1 to go to alarm speed or hot-plug speed if  
the corresponding event occurs, while setting Bit 1 enables Fan  
2. Clearing these bits masks the effect of the corresponding  
event on fan speed.  
If Bit 5 of a Temp. Fault Action Register is set, all fans con-  
trolled by the ADM1029 will go to alarm speed if a temperature  
input crosses the corresponding temperature low limit, the  
direction depending on the setting of Bit 3 of the Temp. Con-  
trol register. (0 = alarm when input goes below low limit, 1 =  
alarm when input goes above low limit).  
Registers 20h and 21h are Fan Event Mask Registers. Bits 0 and  
1 of register 20h enable (bit set) or mask (bit clear) the effect of  
a Fan 1 fault (underspeed or fault input) on Fan 1 and Fan 2  
speed. Similarly, Bits 0 and 1 of register 21h enable (bit set)  
Rev. 1 | Page 16 of 50 | www.onsemi.com  
ADM1029  
or mask (bit clear) the effect of a Fan 2 Fault on Fan 1 and  
Fan 2 speed.  
duty cycle that most fans will run reliably at. Note that the PWM  
duty cycle values programmed in to these registers also define  
the PWM duty cycle that the fans will turn on at, in Automatic  
Fan Speed Control Mode. It is recommended that after power-  
up, the PWM duty cycle is set to 33% before enabling Automatic  
Fan Speed Control.  
Registers 38h to 3Eh are GPIO X Event Mask Registers. Bits 0  
and 1 of these registers enable or mask the effect of a GPIO  
assertion on Fan 1 and Fan 2 speed.  
Note: Registers 48h to 4Ah are Temp. Cooling Action Regis-  
ters. Bits 0 and 1 of these registers enable or mask the effect of  
Local, Remote 1, and Remote 2 temperature faults on Fan 1  
and Fan 2 speed. These registers also determine which tempera-  
ture channel controls each fan in automatic fan speed control  
mode, as described later.  
THERMAL TRIP MODE  
The ADM1029 can thermally trip the fan(s) for simple on/off  
fan control, or 2-speed fan control. For example, a fan can be  
programmed to run at 33% duty cycle. If the temperature exceeds  
the high temperature limit set for that temperature channel, the  
fan can automatically trip and run at Alarm Speed. The fan will  
continue to run at Alarm Speed even if the temperature error  
condition subsides, until the Latch Temp Fault bit (Bit 7 of the  
Temp x Fault Action Reg) is cleared in software by writing a 0  
to it. To configure Fan 1 normally, run at 33% but to thermally  
trip to Alarm Speed for a Remote 2 measured temperature of  
70°C, set up the following registers:  
Registers 58h and 59h are AIN Event Mask Registers. Bits 0  
and 1 of these registers enable or mask the effect of an AIN out-  
of-limit event on Fan 1 and Fan 2 speed.  
MODES OF OPERATION  
The ADM1029 has three different modes of operation. These  
modes determine the behavior of the system.  
1. Configure the normal PWM duty cycle for Fan 1 to 33%.  
Fan 1 Minimum/Alarm Speed Reg (0x60) = 0xF5  
2. Set the Remote 2 High Temperature Limit = 70°C.  
Remote 2 Temp High Limit Reg (0x92) = 0x46  
1. PWM Duty Cycle Select Mode (directly sets fan speed under  
software control).  
2. Thermal Trip Mode  
3. Automatic Fan Speed Control Mode  
3. Configure Alarm Speed on Overtemperature function for  
Remote 2 Temperature channel.  
PWM DUTY CYCLE SELECT MODE  
The ADM1029 may be operated under software control by  
clearing bits <1:0> of the three Temp Cooling Action Registers  
(Reg 0x48, 0x49, 0x4A). Once under Software Control, each  
fan speed may be controlled by programming values of PWM  
Duty Cycle in to the device. Values of PWM Duty Cycle between  
0% to 100% may be written to the four LSBs of the Fan 1 and  
Fan 2 Minimum/Alarm Speed Registers (addresses 60h, 61h).  
to control the speed of each fan. Table IV shows the relationship  
between hex values written to the Minimum/Alarm Speed Reg-  
isters and PWM duty cycle obtained.  
Set Bit 1 of Temp 2 Fault Action Reg (0x42)  
4. Enable Fan 1 to be controlled by Remote 2 Temperature.  
Set Bit 0 of Temp 2 Cooling Action Reg (0x4A)  
Once the fan thermally trips to Alarm Speed, it will continue to  
run at Alarm Speed until the temperature drops below the High  
Temperature Limit and the Latch Temp Fault bit (Bit 7 of the  
Temp 2 Fault Action Reg) is cleared to 0.  
EVENT LATCH BITS  
Table IV. PWM Duty Cycle Select Mode  
Certain events that occur will cause latch bits to be set in vari-  
ous registers on the ADM1029. Once a latch bit is set, it will  
need to be cleared by software for the system to return to nor-  
mal operation. To detect if a latch bit has been set, the INT pin  
can be used to signal a latch event to the system supervisor.  
Alternatively, the Status Registers can be polled periodically,  
and any latch bits that are set can be cleared. The events that  
cause latch bits to be set are:  
Hex Value  
PWM Duty Cycle  
00  
01  
02  
03  
04  
05  
06  
07  
08  
09  
0A  
0B  
0C  
0D  
0E  
0F  
0%  
7%  
14%  
20%  
27%  
33% Recommended  
1. Thermal Events. If the fan is run at Alarm Speed on Over-  
temperature or Undertemperature, this will set the Latch  
Temp Fault bit (Bit 7 of the Temp x Fault Action Registers  
0x40–0x42).  
40%  
47%  
53%  
60%  
2. Missing Fan. If a fan is missing, i.e., has been unplugged, the  
Missing Latch bit (Bit 1 of Fan x Status Registers) is set.  
67%  
73%  
80%  
87%  
3. Hotplugged Fan. If a new fan is inserted into the system, Bit  
7 (Hotplug Latch bit) of the Fan x Status Register is set.  
93%  
100% (Default)  
4. FAULT Asserted. If the fan becomes stuck and its FAULT  
output asserts low, Bit 2 (Fault Latch bit) of the Fan x  
Status register is set.  
It is recommended that the minimum PWM duty cycle be set to  
33% (0x05). This has been determined to be the lowest PWM  
5. TACH Failure. If the fan runs underspeed or becomes stuck,  
then Bit 6 (Tach Fault Latch Bit) of the Fan x Status Regis-  
ter is set.  
*Bits <3:0> set the Minimum PWM duty cycle, bits <7:4> set the Alarm Speed  
PWM duty cycle for each fan.  
Rev. 1 | Page 17 of 50 | www.onsemi.com  
ADM1029  
AUTOMATIC FAN SPEED CONTROL  
T
= 5؇C  
RANGE  
The ADM1029 has a local temperature channel and two remote  
temperature channels, which may be connected to an on-chip  
diode-connected transistor on a CPU or a general-purpose  
discrete transistor. These three temperature channels may be  
used as the basis for an automatic fan speed control loop to  
drive fans using Pulsewidth Modulation (PWM).  
100  
93  
87  
C
؇
=
E
10  
G
80  
73  
66  
N
A
R
T
HOW DOES THE CONTROL LOOP WORK?  
60  
53  
47  
40  
33  
The Automatic Fan Speed Control Loop is shown in Figure 10.  
SPIN UP FOR 2 SECONDS  
MAX  
0
5
10  
20  
40  
60  
80  
T
= T  
MIN  
+ T  
T
MAX  
RANGE  
MIN  
TEMPERATURE ؇C  
Figure 11. PWM Duty Cycle vs. Temperature Slopes  
(TRANGE  
)
MIN  
Figure 11 shows the different control slopes determined by the  
TRANGE value chosen, and programmed in to the ADM1029.  
TMIN was set to 0°C to start all slopes from the same point. It  
can be seen how changing the TRANGE value affects the PWM  
Duty Cycle vs. Temperature Slope.  
T
= T  
MIN  
+ T  
RANGE  
T
MAX  
MIN  
TEMPERATURE  
Figure 12 shows how for a given TRANGE, changing the TMIN  
value affects the loop. Increasing the TMIN value will increase  
the TMAX (temperature at which the fan runs full speed) value,  
since TMAX = TMIN + TRANGE. Note, however, that the PWM  
Duty Cycle versus Temperature slope remains exactly the same.  
Changing the TMIN value merely shifts the control slope.  
Figure 10. Automatic Fan Speed Control  
In order for the fan speed control loop to work, certain loop  
parameters need to be programmed in to the device:  
1. TMIN. This is the temperature at which a fan should switch  
on and run at minimum speed. The fan will only turn on  
once the temperature being measured rises above the TMIN  
value programmed. The fan will spin up for a predeter-  
mined time (default = 2 secs). See Fan Spin-Up section  
for more details.  
100  
93  
87  
80  
73  
2. TRANGE. This will be the temperature range over which the  
ADM1029 will automatically adjust fan speed. As the tempera-  
ture increases beyond TMIN, the PWM duty cycle will be  
increased accordingly. The TRANGE parameter actually defines  
the fan speed versus temperature slope of the control loop.  
66  
60  
53  
47  
40  
33  
3. TMAX. This is defined as the temperature at which a fan  
will be at its maximum speed. At this temperature, the PWM  
duty cycle driving the fan will be 100%. TMAX is given by  
TMIN + TRANGE. Since this parameter is the sum of the TMIN  
and TRANGE parameters, it does not need to be programmed  
into a register on-chip.  
0
T
20  
60  
T
80  
+ T  
40  
= T  
MIN  
MIN  
MAX  
RANGE  
TEMPERATURE ؇C  
4. Programmable hysteresis is included in the control loop to  
prevent the fans continuously switching on and off if the  
temperature is close to TMIN. The fans will continue to run  
Figure 12. Effect of Increasing TMIN Value on Control Loop  
FAN SPIN-UP  
until such time as the temperature drops below TMIN–THYST  
The four MSBs of the TRANGE/THYST registers (Registers  
0x88, 0x89, 0x8A) contain a temperature hysteresis value  
that can be programmed from 0001 to 1111. This allows a  
temperature hysteresis range from 1°C to 15°C for each  
temperature measurement channel.  
.
As previously mentioned, once the temperature being measured  
exceeds the TMIN value programmed, the fan will turn on at  
minimum speed (default = 33% duty cycle). However, the prob-  
lem with fans being driven by PWM is that 33% duty cycle is  
not enough to reliably start the fan spinning. The solution is to  
Rev. 1 | Page 18 of 50 | www.onsemi.com  
ADM1029  
spin the fan up for a predetermined time, and once the fan has  
spun up, its running speed may be reduced in line with the  
temperature being measured.  
100  
93  
87  
80  
73  
66  
60  
53  
47  
40  
33  
The ADM1029 allows fan spin-up times between 1/64 second  
and 16 seconds. The Fan Spin-Up Register (Register 0x0C)  
allows the spin-up time for the fans to be programmed. Bit 3  
of this register, when set, disables fan spin-up for both fans.  
C
؇
= 40  
E
G
N
A
Table V. Fan Spin-Up Times  
Spin-Up Times  
R
T
Bits 2:0  
(Fan Spin-Up Register)  
000  
001  
010  
011  
100  
101  
110  
111  
16 Seconds  
8 Seconds  
4 Seconds  
0
T
20  
40  
60  
T
= T + T  
MIN RANGE  
MIN  
MAX  
LOCAL TEMPERATURE ؇C  
2 Seconds (Default)  
1 Second  
a.  
1/4 Second  
1/16 Second  
1/64 Second  
100  
93  
87  
80  
73  
66  
60  
53  
47  
40  
33  
Once the Automatic Fan Speed Control Loop parameters have  
been chosen, the ADM1029 device may be programmed. The  
ADM1029 is placed into Automatic Fan Speed Control Mode  
by writing to the three Temperature Cooling Action Registers  
(Registers 0x48, 0x49, 0x4A). The device powers up in Auto-  
matic Fan Speed Control Mode by default, as long as the TMIN  
Install pin (Pin 18) does not have the disable option selected  
(TMIN/Install pin tied low or high). The default setting is that  
both fans will run at the fastest speed calculated by all three  
C
؇
= 80  
E
G
N
A
R
T
/
temperature channels. The control mode offers flexibility in that  
the user can decide which temperature channel/channels control  
each fan (five options).  
0
T
20  
40  
70  
= T  
80  
T
+ T  
RANGE  
MIN  
MAX  
MIN  
REMOTE TEMPERATURE ؇C  
b.  
Table VI. Automatic Mode Fan Behavior  
Figure 13. Max Speed Calculated by Local and Remote  
Temperature Control Loops Drives Fans  
Option  
Temperature Cooling Action  
The local temperature’s TMAX will thus be 60  
shows the control loop for the Remote 1 Temperature channel. Its  
TMIN value has been set to 0 C, while its TRANGE = 80 C. There-  
fore, the Remote 1 Temperature’s TMAX value will be 80 C.  
°C. Figure 13b  
1
Bit 0 Register 0x49 and/or Bit 1 Reg 0x4A =  
Remote Temp 1 Controls Fan 1, Remote Temp 2  
Controls Fan 2  
°
°
°
2
3
4
5
Bit 0 Register 0x48 and Bit 1 Register 0x48 = 1  
Local Temp Controls Fan 1 and/or Fan 2  
Bit 0 Register 0x49 and Bit 1 Register 0x49 =  
Remote Temp 1 Controls Fan 1 and/or Fan 2  
Bit 0 Register 0x4A and Bit 1 Register 0x4A =  
Remote Temp 2 Controls Fan 1 and/or Fan 2  
Bits 0, 1 Reg 0x48, 0x49, 0x4A = 1 Max Speed  
Calculated by Local and Remote Temperature  
Channels Controls Fans 1 and/or 2  
If both temperature channels measure 40°C, both control  
loops will calculate a PWM duty cycle of 66%. Therefore, the  
fans will be driven at 66% duty cycle.  
If both temperature channels measure 20°C, the local channel  
will calculate 33% PWM duty cycle, while the Remote 1  
channel will calculate 50% PWM duty cycle. Thus, the fans will  
be driven at 50% PWM duty cycle. Consider the local temperature  
measuring 60°C, while the Remote 1 temperature is measuring  
70 C. The PWM duty cycle calculated by the local temperature  
°
When Option 5 is chosen, this offers increased flexibility. The  
Local and Remote temperature channels can have independently  
programmed control loops with different control parameters.  
Whichever control loop calculates the fastest fan speed based on  
the temperature being measured, drives both fans.  
control loop will be 100% (since the temperature = TMAX). The  
PWM duty cycle calculated by the Remote 1 temperature  
control loop at 70°C will be approximately 90%. So the fans will  
run full speed (100% duty cycle). Remember that the fan speed  
will be based on the fastest speed calculated, and is not necessarily  
based on the highest temperature measured. Depending on the  
control loop parameters programmed, a lower temperature on one  
channel may actually calculate a faster speed than a higher  
temperature on another channel.  
Figure 13 shows how the fan’s PWM duty cycle is determined  
by two independent control loops. This is the type of Automode  
Fan Behavior seen when Bits 0 and 1 of all three Temperature  
Cooling Action Registers = 11. Figure 13a shows the control  
loop for the Local Temperature channel. Its TMIN value has  
been programmed to 20°C, and its TRANGE value is 40°C.  
Rev. 1 | Page 19 of 50 | www.onsemi.com  
ADM1029  
PROGRAMMING THE AUTOMATIC FAN SPEED  
CONTROL LOOP  
Table VII. Programming PWM Duty Cycle  
Decimal Value  
PWM Duty Cycle  
1. Program a value for TMIN  
2. Program a value for the slope TRANGE  
3. TMAX = TMIN + TRANGE  
.
00  
01  
0%  
7%  
.
.
02  
03  
14%  
20%  
4. Program a value for Fan Spin-up Time.  
04  
05  
27%  
33% Recommended  
5. Program the desired Automatic Fan Speed Control Mode  
Behavior, i.e., which temperature channel controls each fan.  
06  
07  
40%  
47%  
OTHER CONTROL LOOP PARAMETERS?  
Having programmed all the above loop parameters, are there  
any other parameters to worry about?  
08  
09  
53%  
60%  
10 (0x0A)  
11 (0x0B)  
12 (0x0C)  
13 (0x0D)  
14 (0x0E)  
15 (0x0F)  
67%  
73%  
TMIN was defined as being the temperature at which a fan  
switched on and ran at minimum speed. This minimum speed  
should be set to 33%. If the minimum PWM duty cycle is  
programmed to 33%, the fan control loops will operate as previ-  
ously described.  
80%  
87%  
93%  
100% (Default)  
It should be noted, however, that changing the minimum PWM  
duty cycle affects the control loop behavior.  
*Bits <3:0> set the Minimum PWM duty cycle for Automatic Mode. Bits <7:4>  
set the Alarm Speed PWM duty cycle.  
The temperature at which each fan will run full speed (100%  
duty cycle) is given by:  
100  
93  
TMAX = TMIN + (( Max DCMin DC) × TRANGE/10)  
87  
where,  
C
80  
؇
3
TMAX  
TMIN  
= Temperature at which fan runs full speed  
= Temperature at which fan will turn on  
= 40  
73  
E
G
N
A
R
T
2
66  
Max DC = Maximum Duty Cycle (100%) = 15 decimal  
Min DC = Duty Cycle at TMIN, programmed into Fan Speed  
Config Register (default = 33% = 5 decimal)  
60  
53  
47  
40  
33  
1
TRANGE  
= PWM Duty Cycle versus Temperature Slope  
Example 1  
TMIN  
=
=
0°C, TRANGE = 40°C  
53% = 8 decimal (Table VII)  
Min DC  
0
T
16  
28  
40  
60  
Calculate TMAX  
MIN  
TEMPERATURE ؇C  
TMAX = TMIN + (( Max DC–Min DC) × TRANGE/10)  
TMAX = 0 + ((100% DC – 53% DC) × 40/10)  
TMAX = 0 + ((15 – 8)× 4) = 28  
Figure 14. Effect of Changing Minimum Duty Cycle on  
Control Loop with Fixed TMIN and TRANGE Values  
TMAX = 28؇C. (As seen on Slope 2 of Figure 14)  
Slope 1 of Figure 14 shows TMIN set to 0°C and the TRANGE  
Example 2  
chosen is 40°C. In this case, the fan’s PWM duty cycle will vary  
over the range 33% to 100%. The fan will run full speed at  
40°C. If the minimum PWM duty cycle at which the fan runs at  
TMIN is changed, its effect can be seen on Slopes 2 and 3. Take  
Case 2, where the minimum PWM duty cycle is reprogrammed  
from 33% (default) to 53%. The fan will actually reach full speed  
at a much lower temperature, 28°C. Case 3 shows that when  
the minimum PWM duty cycle was increased to 73%, the tem-  
perature at which the fan ran full speed was 16°C. So the effect  
of increasing the minimum PWM duty cycle, with a fixed TMIN  
and fixed TRANGE, is that the fan will actually reach full speed  
(TMAX) at a lower temperature than TMIN + TRANGE. How can  
TMAX be calculated?  
TMIN = 0°C, TRANGE = 40°C  
Min DC = 73% = 11 decimal (Table VII)  
Calculate TMAX  
TMAX = TMIN + ((Max DC–Min DC) × TRANGE/10)  
TMAX = 0 + ((100% DC – 73% DC) × 40/10)  
TMAX = 0 + ((15 – 11) × 4) = 16  
TMAX = 16؇C. (As seen on Slope 3 of Figure 14)  
Example 3  
TMIN = 0°C, TRANGE = 40°C  
Min DC = 33% = 5 decimal from Table IV  
Calculate TMAX  
TMAX = TMIN + ((Max DC–Min DC) × TRANGE/10)  
TMAX = 0 + ((100% DC – 33% DC) × 40/10)  
TMAX = 0 + ((15 – 5) × 4) = 40  
In Automatic Fan Speed Control Mode, the registers holding  
the minimum PWM duty cycle at TMIN, are the Minimum/  
Alarm Speed Registers (addresses 60h, 61h). Table VII shows  
the relationship between the decimal values written to the Mini-  
mum/Alarm Speed Registers and PWM duty cycle obtained.  
TMAX = 40؇C. (As seen on Slope 1 of Figure 14)  
Rev. 1 | Page 20 of 50 | www.onsemi.com  
ADM1029  
TEMP COOLING ACTION (CONFIGURE REG 0x48 FOR LOCAL  
TEMP, REG 0x49 FOR REMOTE 1 TEMP AND REG 0x4A FOR  
REMOTE 2 TEMP)  
PROGRAM FAN  
MINIMUM DUTY CYCLE  
FAN 1 (REG 0x60)  
FAN 2 (REG 0x61)  
BIT 0 (REG 0x49) AND/OR BIT 1 (REG 0x4A) = 1  
REMOTE 1 TEMP CONTROLS FAN 1  
REMOTE 2 TEMP CONTROLS FAN 2  
OPTION 1  
BIT 0 (REG 0x48) AND BIT 1 (REG 0x48) = 1  
LOCAL TEMP CONTROLS FAN 1 AND/OR FAN 2  
OPTION 2  
OPTION 3  
OPTION 4  
CONFIGURE TEMP  
COOLING ACTION  
BIT 0 (REG 0x49) AND BIT 1 (REG 0x49) = 1  
REMOTE 1 TEMP CONTROLS FAN 1 AND/OR FAN 2  
LOCAL TEMP (REG 0x48)  
REMOTE 1 TEMP (REG 0x49)  
REMOTE 2 TEMP (REG 0x4A)  
BIT 0 (REG 0x4A) AND BIT 1 (REG 0x4A) = 1  
REMOTE 2 TEMP CONTROLS FAN 1 AND/OR FAN 2  
BIT 0, 1 (REG 0x48, 0x49, 0x4A) = 1  
FAN 1 AND/OR FAN 2 RUNS AT FASTEST SPEED  
CALCULATED BY ALL TEMPERATURE CHANNELS  
OPTION 5  
PROGRAM FAN START  
TEMPERATURE, T  
MIN  
FAN 1  
REMOTE 1  
TEMPERATURE  
FAN 1  
LOCAL TEMP (REG 0x80)  
REMOTE 1 TEMP (REG 0x81)  
REMOTE 2 TEMP (REG 0x82)  
PROGRAM TEMP-TO-FAN  
SPEED CONTROL SLOPE,  
ADM1029  
LOCAL TEMP  
ADM1029  
T
RANGE  
LOCAL TEMP (REG 0x88)  
REMOTE 1 TEMP (REG 0x89)  
REMOTE 2 TEMP (REG 0x8A)  
REMOTE 2  
TEMPERATURE  
OPTION 1  
OPTION 2  
FAN 2  
FAN 2  
CONFIGURE CONTROL  
LOOP HYSTERESIS  
LOCAL TEMP (REG 0x88)  
REMOTE 1 TEMP (REG 0x89)  
REMOTE 2 TEMP (REG 0x8A)  
REMOTE 1  
TEMPERATURE  
REMOTE 1  
TEMPERATURE  
FAN 1  
FAN 1  
CONFIGURE FAN  
SPIN-UP TIME  
(REGISTER 0x0C)  
ADM1029  
ADM1029  
CONFIGURE PWM DRIVE  
FREQUENCY  
FAN 1 (REG 0x68)  
FAN 2 (REG 0x69)  
REMOTE 2  
TEMPERATURE  
REMOTE 2  
TEMPERATURE  
OPTION 4  
OPTION 3  
FAN 2  
FAN 2  
CONFIGURE TACH  
OSCILLATOR FREQUENCY  
FAN 1  
REMOTE 1  
TEMPERATURE  
FAN 1 (REG 0x68)  
FAN 2 (REG 0x69)  
MEASURE  
FAN SPEED  
ADM1029  
LOCAL TEMP  
FAN 1 (REG 0x70)  
FAN 2 (REG 0x71)  
REMOTE 2  
TEMPERATURE  
OPTION 5  
FAN 2  
Figure 15. Configuring Automatic Fan Speed Control  
Rev. 1 | Page 21 of 50 | www.onsemi.com  
ADM1029  
Table VIII. Resistor Ratios for Setting TMIN and Number of Fans Installed Using TMIN/INSTALL Pin (Pin 18)  
3 MSBs  
of ADC  
Ideal Ratio R1  
R2/(R1 + R2) (k)  
R2  
(k)  
Actual Error  
R2/(R1 + R2) (%)  
Fans  
Installed  
TMIN  
111  
110  
101  
100  
011  
010  
001  
000  
N/A  
0
ϱ
1
0.82  
0
Disabled  
48°C  
40°C  
2
2
2
2
1
1
1
1
0.8125  
0.6875  
0.5625  
0.4375  
0.3125  
0.1875  
N/A  
18  
22  
12  
15  
47  
82  
ϱ
82  
47  
15  
12  
22  
18  
0
0.75  
–0.63  
–0.69  
0.69  
0.63  
–0.75  
0
0.6812  
0.5556  
0.4444  
0.3188  
0.18  
32°C  
32°C  
40°C  
48°C  
Disabled  
0
In this case, since the Minimum Duty Cycle is the default 33%,  
the equation for TMAX reduces to:  
FAN-RELATED REGISTERS  
Table IX is a list of registers on the ADM1029 that are specific  
to fan speed measurement and control:  
TMAX = TMIN + ((Max DC – Min DC) × TRANGE/10)  
TMAX = TMIN + ((15 – 5) × TRANGE/10)  
TMAX = TMIN + (10 × TRANGE/10)  
Table IX. Fan-Specific Registers  
TMAX = TMIN + TRANGE  
Address  
Description  
ENABLING AUTOMATIC FAN SPEED CONTROL USING  
TMIN/INSTALL PIN (PIN 18)  
0x02  
0x03  
0x07  
0x08  
0x09  
0x10  
0x11  
0x18  
0x19  
0x20  
0x21  
0x48  
0x49  
0x4A  
0x60  
0x61  
0x68  
0x69  
0x70  
0x71  
0x78  
0x79  
Fans Supported By Controller  
Fans Supported In System  
Set Fan x Alarm Speed  
Set Fan x Hot-Plug Speed  
Set Fan x Full Speed  
Fan 1 Status  
Automatic fan control can also be enabled in hardware by Pin  
18 (TMIN/INSTALL). This is an 8-level input with multiple  
functions, which is sampled only at power-up.  
If only one fan is installed, the voltage on Pin 18 should be kept  
at less than VCC/2, which clears Bit 1 of register 03h. Within this  
voltage range, four voltage levels define the minimum temperature  
at which the fan will operate in automatic speed control mode.  
Fan 2 Status  
Fan 1 Fault Action  
Fan 2 Fault Action  
Fan 1 Event Mask  
If two fans are installed, the voltage on Pin 18 should be between  
Fan 2 Event Mask  
V
CC/2 and VCC, which sets Bit 1 of register 03h. Within this  
Local Temp Cooling Action  
Remote 1 Cooling Action  
Remote 2 Cooling Action  
Fan 1 Minimum/Alarm Speed  
Fan 2 Minimum/Alarm Speed  
Fan 1 Configuration  
Fan 2 Configuration  
Fan 1 Tach Value  
voltage range, four voltage levels define the minimum temperature  
at which the fans will operate in automatic speed control mode.  
Resistor values for setting the voltage on Pin 18 are given in  
Table VIII. If automatic fan speed control is not used, Pin 18 can  
simply be strapped to ground (one fan) or VCC (two fans),  
depending on how many fans are installed. Under this condi-  
tion, the fans will run full speed until the device is written to by  
software to change fan speed.  
Fan 2 Tach Value  
When automatic fan speed control is enabled at power-up by  
the TMIN/INSTALL pin, Bit 4 of the Configuration register is  
set to enable monitoring, and Bits 0 and 1 of all Temp. Cooling  
Action Registers are set, so any temperature channel will auto-  
matically control all fans that are installed.  
Fan 1 Tach High Limit  
Fan 2 Tach High Limit  
FAN CONFIGURATION REGISTERS  
Registers 0x68 and 0x69 are the Fan 1 and Fan 2 Configuration  
Registers. These allow the PWM output frequencies to be selected  
for each fan. The default PWM drive frequency is 250 Hz. Bits  
<7:6> adjust the fan tach oscillator frequency for fan tach mea-  
surements. Bits <3:0> allow the Hot Plug PWM duty cycle value  
for each fan to be programmed.  
Note: if automatic fan speed control is enabled and an event  
occurs that would cause a fan to go to alarm or hot-plug speed  
(e.g., temperature fault), that event will override the automatic  
fan speed control. If the event affects only one fan, the other fan  
will remain under automatic control.  
Figures 16 and 17 show how to configure the fans to handle  
thermal or fault events.  
Rev. 1 | Page 22 of 50 | www.onsemi.com  
ADM1029  
FAN FAULT ACTION (CONFIGURE REG 0x18 FOR FAN 1, REG 0x19 FOR FAN 2)  
BIT 0 = 1  
BIT 1 = 1  
BIT 2 = 1  
ASSERT CFAULT ON FAN FAULT (TACH FAILURE OR FAULT ASSERTION)  
ASSERT INT ON FAN FAULT (TACH FAILURE OR FAULT ASSERTION)  
ASSERT CFAULT IF FAN HOT UNPLUGGED  
CONFIGURE FAN  
NORMAL SPEED  
SET FAN 1 = 33%  
SET FAN 2 = 33%  
BIT 3 = 1  
BIT 4 = 1  
BIT 5 = 1  
BIT 6 = 1  
ASSERT INT IF FAN HOT UNPLUGGED  
FAN 1 (REG 0x60)  
FAN 2 (REG 0x61)  
THERMAL OVERRIDE IF IN SLEEP MODE (FAN RUNS AT ALARM SPEED)  
DRIVE FAULT LOW IF A FAN FAULT IS DETECTED  
IF CFAULT PULLED LOW EXTERNALLY, RUN FAN AT HOT-PLUG SPEED  
BIT 7 = 1  
IF CFAULT PULLED LOW EXTERNALLY, RUN FAN AT ALARM SPEED  
CONFIGURE FAN  
ALARM SPEED  
7
6
5
4
3
2
1
0
DEFAULTS  
FAN 1 = 100%  
FAN 2 = 100%  
FAN 1 (REG 0x60)  
FAN 2 (REG 0x61)  
FAN TACH  
FAILURE OR  
FAULT PIN  
LOW?  
CFAULT  
YES  
CONFIGURE FAN  
HOT-PLUG SPEED  
DEFAULTS  
FAN 1 = 100%  
FAN 2 = 100%  
FAN TACH  
INT  
CFAULT  
INT  
FAILURE OR  
FAULT PIN  
LOW?  
FAN 1 (REG 0x68)  
FAN 2 (REG 0x69)  
YES  
HAS A FAN  
BEEN HOT  
UNPLUGGED?  
YES  
CONFIGURE FAN FAULT  
ACTION  
HAS A FAN  
BEEN HOT  
UNPLUGGED?  
FAN 1 (REG 0x18)  
FAN 2 (REG 0x19)  
YES  
OVER-  
FAN RUNS AT ALARM SPEED  
TEMPERATURE  
DETECTED IN  
SLEEP MODE?  
YES  
CONFIGURE FAN FAULT  
MASK REGISTERS  
FAN 1 (REG 0x20)  
FAN 2 (REG 0x21)  
FAN TACH  
FAILURE OR  
FAULT PIN  
LOW?  
YES  
FAN RUNS AT HOT-PLUG SPEED  
FAN RUNS AT ALARM SPEED  
HAS CFAULT BEEN  
PULLED LOW?  
YES  
HAS CFAULT BEEN  
PULLED LOW?  
YES  
FAN TACH  
FAN 1 RUNS ALARM SPEED  
YES  
FAILURE OR  
FAULT PIN  
LOW?  
BIT 0 = 1  
BIT 1 = 1  
RUN FAN 1 AT ALARM SPEED  
IF FAN FAULT IS DETECTED  
RUN FAN 2 AT ALARM SPEED IF  
FAN FAULT IS DETECTED  
BITS 2 7 DON'T CARE  
FAN TACH  
FAILURE OR  
FAULT PIN  
LOW?  
FAN 2 RUNS ALARM SPEED  
YES  
FAN FAULT MASK (CONFIGURE REG 0x20 FOR  
FAN 1, REG 0x21 FOR FAN 2)  
Figure 16. Fan Configuration Flowchart  
Rev. 1 | Page 23 of 50 | www.onsemi.com  
ADM1029  
GPIO EVENT MASK (CONFIGURE REG 0x38 FOR GPIO0,  
REG 0x39 FOR GPIO1.....REG 0x3E FOR GPIO6)  
BIT 0 = 1  
FAN 1 RUNS AT ALARM OR  
HOT-PLUG SPEED IF GPIO PIN  
IS ASSERTED  
IS GPIO  
PIN  
ASSERTED?  
YES  
BIT 1 = 1  
FAN 2 RUNS AT ALARM OR  
HOT-PLUG SPEED IF GPIO PIN  
IS ASSERTED  
FAN RUNS AT ALARM  
OR HOT-PLUG SPEED  
BITS 2 7 DON'T CARE  
CONFIGURE GPIO EVENT  
MASK REGISTERS  
(REG 0x38 0x3E)  
PROGRAM FAN START  
TEMPERATURE, T  
MIN  
LOCAL TEMP (REG 0x80)  
REMOTE 1 TEMP (REG 0x81)  
REMOTE 2 TEMP (REG 0x82)  
CONFIGURE TEMP  
COOLING ACTION  
LOCAL TEMP (REG 0x48)  
REMOTE 1 TEMP (REG 0x49)  
REMOTE 2 TEMP (REG 0x4A)  
PROGRAM TEMP-TO-FAN  
SPEED CONTROL  
AUTOMATIC FAN  
SPEED CONTROL  
CONFIGURATION  
SLOPE, T  
RANGE  
LOCAL TEMP (REG 0x88)  
REMOTE 1 TEMP (REG 0x89)  
REMOTE 2 TEMP (REG 0x8A)  
(REFER TO AUTOMATIC FAN SPEED  
CONTROL FLOWCHART)  
CONFIGURE AIN EVENT  
MASK REGISTERS  
AIN1 (REG 0x58)  
AIN2 (REG 0x59)  
CONFIGURE CONTROL  
LOOP HYSTERESIS  
LOCAL TEMP (REG 0x88)  
REMOTE 1 TEMP (REG 0x89)  
REMOTE 2 TEMP (REG 0x8A)  
CONFIGURE FAN  
SPIN-UP TIME  
REGISTER 0x0C  
CONFIGURE PWM DRIVE  
FREQUENCY  
AIN EVENT MASK (CONFIGURE REG 0x58 FOR  
AIN 0, REG 0x59 FOR AIN 1)  
FAN1 (REG 0x68)  
FAN2 (REG 0x69)  
BIT 0 = 1  
FAN 1 RUNS AT ALARM SPEED  
IF AIN OUT-OF-LIMIT EVENT  
OCCURS  
BIT 1 = 1  
FAN 2 RUNS AT ALARM SPEED  
IF AIN OUT-OF-LIMIT EVENT  
OCCURS  
CONFIGURE TACH  
OSCILLATOR FREQUENCY  
BITS 2 7 DON'T CARE  
IS AIN  
PIN  
ASSERTED?  
YES  
FAN RUNS AT  
ALARM SPEED  
FAN1 (REG 0x68)  
FAN2 (REG 0x69)  
MEASURE  
FAN SPEED  
FAN1 (REG 0x70)  
FAN2 (REG 0x71)  
Figure 17. Fan Configuration Flowchart (Continued)  
Rev. 1 | Page 24 of 50 | www.onsemi.com  
ADM1029  
RESET INPUT  
If Bit 6 of a Temp. Fault Action Register is set, INT will be  
asserted if a temperature input crosses the corresponding  
temperature low limit, the direction depending on the setting  
of Bit 3 of the Temp. Fault Action register. (0 = INT when  
temperature goes below low limit, 1 = INT when temperature  
goes above low limit).  
Pin 12 is an active-low system RESET input. Taking this pin  
low will generate a system reset, which will reset all registers to  
their default values.  
ANALOG INPUTS  
Pins 19 and 20 of the ADM1029 are dual-function pins. They  
may be configured as general-purpose logic I/O pins by setting  
Bits 0, 1 of the GPIO Present/AIN Register (address 05h) or  
as 0 V to 2.5 V analog inputs by clearing these bits.  
If Bit 1 of a Fan Fault Action Register (18h or 19h) is set,  
INT will be asserted when a tach measurement for the corre-  
sponding fan exceeds the set limit .  
If Bit 1 of a Fan Fault Action Register (18h or 19h) is set,  
INT will be asserted when the fan fault input pin for the cor-  
responding fan is asserted (low).  
In the analog input mode, Pins 19 and 20 have an input range  
of 0 V to 2.5 V. By suitable input scaling, the analog input may  
be configured to measure other voltage ranges such as system  
power supply voltages. If more than one ADM1029 is used in a  
system, several such voltages may be monitored.  
If Bit 2 of an AIN Behavior Register is set (50h—AIN0, 51h—  
AIN1), INT will be asserted if the corresponding AIN high  
limit is exceeded.  
The measured values of AIN0 and AIN 1 are stored in the  
AIN0 and AIN1 Value Registers (addresses B8h and B9h) and  
are compared to high and low limits stored in the AIN0 and  
AIN1 High and Low Limit Registers (addresses A8h, A9h and  
B0h, B1h).  
If Bit 6 of an AIN Behavior Register is set, INT will be asserted  
if the corresponding analog input crosses its AIN low limit,  
the direction depending on the setting of Bit 3 of the AIN  
Behavior register. (0 = INT when input goes below low limit,  
1 = INT when input goes above low limit).  
The response of the ADM1029 to an out-of-limit measurement  
on AIN0 or AIN1 depends on the status of the AIN0 and AIN1  
Behavior Registers (Registers 50h, 51h). The response of  
CFAULT, INT, and fan speed to temperature events depends  
on the setting of these registers, as detailed in the register tables  
later in this data sheet. Figure 18 shows how the AIN pins can  
be configured to respond to different events.  
FAN FREE-WHEELING TEST  
The Fan Free Wheeling Test is used to diagnose fans connected  
to the ADM1029 to ensure that they are operating correctly.  
Large fans tightly coupled in a duct can affect each other’s air-  
flow. If one fan has failed it may not be apparent, as the other  
fan moving can suck air through the faulty fan causing it to spin.  
The ADM1029 will spin each fan up separately with the other  
powered down and measure the fan speed of both. When it tries  
to spin the failed fan with the working fan off, the fan speed  
measurement will fail, and the faulty fan will be detected. The  
Fan Free-Wheel Test can be invoked at any time in software by  
setting Bit 3 of the Configuration Register (Reg. 0x01). The Fan  
Free-Wheel Test normally takes about 10 seconds. Once the  
Fan Free-Wheel test has completed, Bit 3 will automatically  
clear to 0.  
ANALOG MONITORING CYCLE  
The ADM1029 performs a sequential “round-robin,” monitor-  
ing cycle on all analog inputs and temperature inputs that are  
enabled. A conversion on AIN0 or AIN1 typically takes 11.6 ms,  
while an external temperature conversion takes 185.6 ms.  
INTERRUPT (INT) OUTPUT  
The INT output is an open-drain output with selectable polar-  
ity, intended to communicate fault conditions to the host  
processor. The polarity is set to active low by clearing Bit 7 of  
the Configuration Register (address 01h) or to active high by  
setting this bit.  
Automatic Fan Free-Wheel Test  
Whenever a fan is hot-plugged, the Fan Free-Wheel Test is  
automatically invoked. Bit 3 gets set high automatically and once  
the test has completed, self-clears to 0. If 2 fans are installed in  
the system, the Fan Free-Wheel Test is invoked by removing the  
suspect fan and hotplugging a new one. When the suspect fan  
(e.g., Fan 1) is removed, the Missing bit (Bit 0) and Missing  
Latch bit (Bit 1) of the Fan 1 Status Register are set. Fan 2 will  
then automatically run at HotPlug Speed. If the faulty fan is  
replaced, the HotPlug Latch bit (Bit 7) is set and the Missing  
bit (Bit 0) self-clears. (However, the Missing Latch bit remains  
set.) Fan 2 will return to its previous value automatically and  
the Fan Free-Wheel Test is invoked. Fan 1 is run at 100% while  
Fan 2 is turned off. Fan 2 is then run at 100% with Fan 1 turned  
off. Both fans are then spun-up for the Fan Spin-up time. Note  
that the Hotplug Latch bit and Missing Latch bit remains set  
(Bits 7 and 1). These need to be cleared to 0 before a subse-  
quent Fan Free-Wheel Test can occur. Otherwise, subsequent  
fan removals and insertions are ignored.  
INT can be asserted if any of the following conditions occur:  
A hot-plug event.  
Setting Bit 6 of the Configuration Register (address 01h)  
forces INT to be asserted.  
When a GPIO pin is configured as an input by setting Bit 0 of  
the corresponding GPIO Behavior Register and Bit 3 of the  
GPIO Behavior Register is also set, INT will be asserted when  
the logic input is asserted (high or low, depending on the polar-  
ity bit, Bit 1 of the corresponding GPIO Behavior Register).  
If Bit 2 of a Temp. Fault Action Register is set (40h—Local  
Sensor, 41h—Remote 1, 42h—Remote 2), INT will be asserted  
if the corresponding temperature high limit is exceeded.  
Rev. 1 | Page 25 of 50 | www.onsemi.com  
ADM1029  
AIN PINS ENABLE (REG 0x05)  
BIT 0 = 0  
BIT 1 = 0  
BIT 2 7  
PIN 19 CONFIGURED AS AIN0  
ENABLE PINS FOR AIN  
FUNCTION  
PIN 20 CONFIGURED AS AIN1  
(REGISTER 0x05)  
RESERVED FOR OTHER  
FUNCTIONS  
AIN PINS BEHAVIOR (REG 0x50 CONFIGURES AIN0, REG 0x51 CONFIGURES AIN1)  
BIT 0 = 1  
BIT 1 = 1  
BIT 2 = 1  
BIT 3 = 0  
BIT 3 = 1  
BIT 4 = 1  
CFAULT ASSERTED IF AIN VALUE EXCEEDS AIN HIGH LIMIT  
FANS RUN ALARM SPEED IF AIN VALUE EXCEEDS AIN HIGH LIMIT  
INT ASSERTED IF AIN VALUE EXCEEDS AIN HIGH LIMIT  
CONFIGURE AIN PINS  
BEHAVIOR  
AIN0 (REG 0x50)  
AIN1 (REG 0x51)  
ALARM GENERATED (INT, CFAULT, OR ALARM SPEED) WHEN AIN GOES BELOW AIN LOW LIMIT  
ALARM GENERATED (INT, CFAULT, OR ALARM SPEED) WHEN AIN GOES ABOVE AIN LOW LIMIT  
CFAULT ASSERTED IF AIN VALUE EXCEEDS AIN LOW LIMIT. BIT 3 DECIDES WHETHER CFAULT  
IS ASSERTED GOING ABOVE OR BELOW THE LOW LIMIT  
BIT 5 = 1  
BIT 6 = 1  
BIT 7 = 1  
FANS RUN ALARM SPEED IF AIN VALUE CROSSES THE AIN LOW LIMIT. BIT 3 DECIDE WHETHER  
ALARM SPEED IS TRIGGERED GOING ABOVE OR BELOW THE LOW LIMIT  
INT ASSERTED IF AIN VALUE CROSSES THE AIN LOW LIMIT. BIT 3 DECIDES WHETHER INT IS  
ASSERTED GOING ABOVE OR BELOW THE LOW LIMIT  
CONFIGURE AIN EVENT  
MASK  
THIS BIT LATCHES AN OUT-OF-LIMIT AIN EVENT. CLEARED BY WRITING A '0'  
AIN0 (REG 0x58)  
AIN1 (REG 0x59)  
7
6
5
4
3
2
1
0
AIN EVENT MASK  
(CONFIGURE REG 0x58 FOR  
AIN0, REG 0x59 FOR AIN1)  
IS AIN  
VALUE >  
AIN HIGH  
LIMIT?  
BIT 0 = 1  
BIT 1 = 1  
RUN FAN 1 AT ALARM SPEED IF AIN OUT-OF-  
LIMIT EVENT IS DETECTED  
RUN FAN 2 AT ALARM SPEED IF AIN OUT-OF-  
LIMIT EVENT IS DETECTED  
CFAULT  
IS AIN  
VALUE >  
AIN HIGH  
LIMIT?  
YES  
BITS 2 7 RESERVED READ BACK ZERO  
FANS RUN ALARM SPEED  
IS AIN  
VALUE >  
AIN HIGH  
LIMIT?  
YES  
CONFIGURE AIN  
HIGH LIMITS  
INT  
AIN0 (REG 0xA8)  
AIN1 (REG 0xA9)  
YES  
AIN ABOVE OR  
BELOW LOW AIN  
LIMIT?  
0 = ALARM BELOW AIN LOW LIMIT  
CONFIGURE AIN  
LOW LIMITS  
1 = ALARM ABOVE AIN LOW LIMIT  
HAS AIN VALUE  
EXCEEDED AIN  
LOW LIMIT?  
AIN0 (REG 0xB0)  
AIN1 (REG 0xB1)  
CFAULT  
FANS RUN ALARM SPEED  
INT  
YES  
HAS AIN VALUE  
EXCEEDED AIN  
LOW LIMIT?  
MEASURE AIN  
VOLTAGES  
AIN0 (REG 0xB8)  
AIN1 (REG 0xB9)  
YES  
HAS AIN VALUE  
EXCEEDED AIN  
LOW LIMIT?  
YES  
Figure 18. Configuring AIN0 and AIN1 Pins  
Rev. 1 | Page 26 of 50 | www.onsemi.com  
ADM1029  
GENERAL PURPOSE LOGIC INPUT/OUTPUTS  
The ADM1029 has six dual-function pins (see Pin Function  
Descriptions section) that may be configured as general-purpose  
Logic I/O pins by setting the appropriate bit(s) of the GPIO  
Present/AIN Register (address 05h) or as their alternate func-  
tions by clearing these bits.  
CFAULT OUTPUT  
The Cascade Fault output (CFAULT), is an open-drain, active  
low output, intended to communicate fault conditions to other  
ADM1029s in a system, without the intervention of the host pro-  
cessor. The other ADM1029’s may then adjust their fans’ speed  
to compensate, depending on the settings of various registers.  
When configured as GPIO pins, each GPIO pin has a Behavior  
Register associated with it (Registers 28h to 2Eh) that may be  
used to configure the operation of the pin.  
CFAULT is asserted if any of the following conditions occurs:  
A hot-plug event.  
Setting Bit 5 of the Configuration Register (address 01h)  
forces CFAULT to be asserted.  
The GPIO pins may be configured as inputs or outputs. When  
used as inputs, they may be configured to:  
When a GPIO pin is configured as an input by setting Bit 0 of  
the corresponding GPIO Behavior Register and Bit 2 of the  
GPIO Behavior Register is also set, CFAULT will be asserted  
when the logic input is asserted (high or low depending on the  
polarity bit, Bit 1 of the corresponding GPIO Behavior Register).  
Be active high or active low.  
Set/clear a bit in the Behavior Register when GP input is  
asserted/deasserted.  
Latch a bit in the Behavior Register when GP input is asserted  
(must be cleared by software).  
If Bit 0 of a Temp. Fault Action Register is set (40h—Local  
Sensor, 41h—Remote 1, 42h—Remote 2), CFAULT will be  
asserted if the corresponding temperature high limit is exceeded.  
Assert CFAULT when GP input asserted.  
Assert INT when GP input asserted.  
If Bit 4 of a Temp. Fault Action Register is set, CFAULT will  
be asserted if a temperature input crosses the corresponding  
temperature low limit, the direction depending on the setting  
of Bit 3 of the Temp. Fault Action Register. (0 = CFAULT  
when input goes below low limit, 1 = CFAULT when input  
goes above low limit).  
Set fan(s) to alarm speed when GP input asserted.  
Set fan(s) to hot-plug speed when GP input asserted.  
When used as outputs, they may be configured to:  
Be active high or low  
Be asserted if a High Temperature Limit is exceeded.  
If Bit 0 of a Fan Fault Action Register (18h or 19h) is set,  
CFAULT will be asserted when a tach measurement for the  
corresponding fan exceeds the set limit.  
Be asserted if a temperature measurement falls below a  
low limit.  
If Bit 0 of a Fan Fault Action Register (18h or 19h) is set,  
CFAULT will be asserted, when the fan fault input pin for  
the corresponding fan is asserted (low).  
Be asserted if a fan fault is detected.  
Be asserted if a fan tach limit is exceeded.  
Be asserted if an AIN high limit is exceeded.  
Be asserted if an analog input falls below a low limit.  
If Bit 0 of an AIN Behavior Register is set (50h—AIN0,  
51h—AIN1), CFAULT will be asserted if the corresponding  
AIN high limit is exceeded.  
Figure 19 shows how to configure the GPIO pins to handle  
different out-of-limit and fault events.  
If Bit 4 of an AIN Behavior Register is set, CFAULT will be  
asserted if an analog input crosses the corresponding AIN low  
limit, the direction depending on the setting of Bit 3 of the  
AIN Behavior Register. (0 = CFAULT when input goes  
below low limit, 1 = CFAULT when input goes above low limit).  
Rev. 1 | Page 27 of 50 | www.onsemi.com  
ADM1029  
GPIO PINS ENABLE (REG 0x05)  
BIT 0 = 1  
BIT 1 = 1  
BIT 2 = 1  
BIT 3 = 1  
BIT 4 = 1  
BIT 5 = 1  
BIT 6 = 1  
BIT 7  
PIN 19 CONFIGURED AS GPIO0  
ENABLE PINS FOR GPIO  
FUNCTION  
PIN 20 CONFIGURED AS GPIO1  
PIN 11 CONFIGURED AS GPIO2  
PIN 13 CONFIGURED AS GPIO3  
PIN 14 CONFIGURED AS GPIO4  
PIN 16 CONFIGURED AS GPIO5  
PIN 17 CONFIGURED AS GPIO6  
RESERVED  
(REGISTER 0x05)  
GPIO PINS BEHAVIOR (REG 0x28 CONFIGURES GPIO0, REG 0x29 CONFIGURES GPIO1, ETC.)  
CONFIGURE GPIO PINS  
BEHAVIOR  
BIT 0  
SETS THE DIRECTION FOR GPIO PIN. A '0' CONFIGURES THE PIN AS AN OUTPUT, A '1' SETS  
THE PIN UP AS AN INPUT  
GPIO0 (REG 0x28)  
|
GPIO6 (REG 0x2E)  
BIT 1  
SETS THE POLARITY FOR GPIO PIN. A '0' MAKES THE PIN ACTIVE LOW, A '1' MAKES THE PIN  
ACTIVE HIGH  
BIT 2 = 1  
IF GPIO PIN IS CONFIGURED AS AN INPUT, CFAULT IS ASSERTED WHEN GPIO IS ASSERTED.  
IF GPIO PIN IS CONFIGURED AS AN OUTPUT, GPIO PIN WILL BE ASSERTED IF A HIGH  
TEMPERATURE LIMIT IS EXCEEDED. THIS CAN BE USED TO SHUT DOWN THE SYSTEM IN AN  
OVER-TEMPERATURE SITUATION.  
BIT 3 = 1  
BIT 4 = 1  
BIT 5 = 1  
BIT 6 = 1  
BIT 7  
IF GPIO PIN IS CONFIGURED AS AN INPUT, INT IS ASSERTED WHEN GPIO IS ASSERTED. IF GPIO  
PIN IS AN OUTPUT, GPIO IS ASSERTED IF A TEMPERATURE LOW LIMIT IS EXCEEDED.  
IF GPIO PIN IS CONFIGURED AS AN INPUT, FANS GO TO ALARM SPEED IF GPIO IS ASSERTED. IF  
GPIO PIN IS AN OUTPUT, GPIO IS ASSERTED IF A FAN TACH LIMIT IS EXCEEDED.  
IF GPIO PIN IS CONFIGURED AS AN INPUT, FANS GO TO HOT-PLUG SPEED IF GPIO IS ASSERTED.  
IF GPIO PIN IS AN OUTPUT, GPIO IS ASSERTED IF A FAN FAULT IS DETECTED (FAULT PIN).  
IF GPIO PIN IS AN INPUT, THIS BIT REFLECTS THE STATE OF GPIO PIN. IF GPIO PIN IS AN  
OUTPUT, GPIO IS ASSERTED IF AN AIN HIGH LIMIT IS EXCEEDED.  
CONFIGURE GPIO EVENT  
MASK  
GPIO0 (REG 0x38)  
|
GPIO6 (REG 0x3E)  
IF GPIO PIN IS AN INPUT, THIS BIT LATCHES A GPIO ASSERTION EVENT. CLEARED BY  
WRITING A '0.' IF GPIO PIN IS AN INPUT, GPIO IS ASSERTED IF AN AIN LOW LIMIT IS EXCEEDED.  
FAN 1 RUNS AT HOT-PLUG  
OR ALARM SPEED  
IS GPIO  
PIN ASSERTED?  
BIT 0 = 1  
BIT 1 = 1  
RUN FAN 1 AT ALARM OR HOT-PLUG SPEED IF GPIO PIN IS ASSERTED  
RUN FAN 2 AT ALARM OR HOT-PLUG SPEED IF GPIO PIN IS ASSERTED  
YES  
BITS 2 7 RESERVED READ BACK ZERO  
FAN 2 RUNS AT HOT-PLUG  
OR ALARM SPEED  
GPIO EVENT MASK (CONFIGURE REG 0x38 FOR GPIO0, REG 0x39 FOR  
GPIO1.....REG 0x3E FOR GPIO6)  
IS GPIO  
PIN ASSERTED?  
YES  
Figure 19. Configuring GPIO Pins  
Rev. 1 | Page 28 of 50 | www.onsemi.com  
ADM1029  
Table X. Register Map  
Address  
Name  
Default Value  
Description  
00  
01  
02  
03  
Status Register  
00h  
Contains the status of various fault conditions.  
Configures the operation of the device.  
Config Register  
0000 0000  
03h  
Fan Supported By Controller  
Fans Supported In System  
Contains the number of fans the device can support.  
0000 00?1  
Contains the number of fans actually supported by the device  
in the application.  
04  
05  
GPIOs Supported By Controller  
GPIO Present/AIN  
7Fh  
Contains the number of GPIO pins the device can support.  
0????111  
Used to configure GPIO pins as GPIO or as their alternate  
analog input function.  
06  
07  
08  
09  
0B  
0C  
0D  
0E  
Temp Devices Installed  
Set Fan x Alarm Speed  
Set Fan x Hot-Plug Speed  
Set Fan x Full Speed  
S/W RESET  
0000 0??1  
00h  
Contains number of temperature sensors installed.  
Writing to appropriate bit(s) makes fan(s) run at alarm speed.  
Writing to appropriate bit(s) makes fan(s) run at hot-plug speed.  
Writing to appropriate bit(s) makes fan(s) run at full speed.  
Writing A6h to this register causes a software reset.  
Configures fan spin-up time.  
00h  
00h  
00h  
Fan Spin-Up  
03h  
Manufacturer’s ID  
Major/Minor Revision  
41h  
This register contains the manufacturer’s ID code for the device.  
00h  
Contains the manufacturer’s code for major and minor revi-  
sions to the device in two nibbles.  
0F  
Manufacturer’s Test Register  
00h  
This register is used by the manufacturer for test purposes. It  
should not be read from or written to in normal operation.  
10  
11  
18  
19  
20  
Fan 1 Status  
0000 0?0?  
0000 0?0?  
BFh  
Contains status information for FAN 1.  
Fan 2 Status  
Contains status information for FAN 2.  
Fan 1 Fault Action  
Fan 2 Fault Action  
Fan 1 Event Mask  
Sets operation of INT, CFAULT, etc., for FAN 1 fault.  
Sets operation of INT, CFAULT, etc., for FAN 2 fault.  
BFh  
FFh  
Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed  
in response to a fault or hot-plug event on FAN 1.  
21  
Fan 2 Event Mask  
FFh  
Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed  
in response to a fault or hot-plug event on FAN 2.  
28  
GPIO0 Behavior  
GPIO1 Behavior  
GPIO2 Behavior  
GPIO3 Behavior  
GPIO4 Behavior  
GPIO5 Behavior  
GPIO6 Behavior  
Local Temperature Offset  
00h  
00h  
00h  
00h  
00h  
00h  
00h  
00h  
Configures the operation of GPIO0.  
Configures the operation of GPIO1.  
Configures the operation of GPIO2.  
Configures the operation of GPIO3.  
Configures the operation of GPIO4.  
Configures the operation of GPIO5.  
Configures the operation of GPIO6.  
29  
2A  
2B  
2C  
2D  
2E  
30  
Offset register for local temperature measurement. The value  
in this register is added to the local temperature value to reduce  
system offset effects.  
31  
32  
Remote 1 Temperature Offset  
Remote 2 Temperature Offset  
00h  
00h  
Offset register for first remote temperature channel (D1). The  
value in this register is added to the temperature value to reduce  
system offset effects.  
Offset register for second remote temperature channel (D2).  
The value in this register is added to the temperature value to  
reduce system offset effects.  
38  
39  
3A  
3B  
GPIO0 Event Mask  
GPIO1 Event Mask  
GPIO2 Event Mask  
GPIO3 Event Mask  
00h  
00h  
00h  
00h  
Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed  
in response to GPIO0 being asserted.  
Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed  
in response to GPIO1 being asserted.  
Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed  
in response to GPIO2 being asserted.  
Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed  
in response to GPIO3 being asserted.  
Rev. 1 | Page 29 of 50 | www.onsemi.com  
ADM1029  
Table X. Register Map (Continued)  
Address  
Name  
Default Value  
Description  
3C  
GPIO4 Event Mask  
00h  
Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed  
in response to GPIO4 being asserted.  
3D  
3E  
40  
41  
42  
48  
49  
4A  
50  
51  
58  
59  
GPIO5 Event Mask  
00h  
00h  
08h  
08h  
08h  
00h  
00h  
00h  
00h  
00h  
00h  
00h  
Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed  
in response to GPIO5 being asserted.  
GPIO6 Event Mask  
Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed  
in response to GPIO6 being asserted.  
Local Temp Fault Action  
Remote 1 Temp Fault Action  
Remote 2 Temp Fault Action  
Local Temp Cooling Action  
Remote 1 Temp Cooling Action  
Remote 2 Temp Cooling Action  
AIN0 Behavior  
Configures the operation of INT, CFAULT, etc. for a Local  
Temp fault (internal temperature sensor).  
Configures the operation of INT, CFAULT, etc. for a Remote  
1 Temp fault (D1 Temperature Sensor).  
Configures the operation of INT, CFAULT, etc. for a Remote  
2 Temp fault (D2 Temperature Sensor).  
Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed  
in response to a Local Temp event (internal temperature sensor).  
Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed  
in response to a Remote 1 Temp event (D1 temperature sensor).  
Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed  
in response to a Remote 2 Temp event (D2 temperature sensor).  
Configures the operation of INT, CFAULT, etc. for a fault on  
Analog Channel 0.  
AIN1 Behavior  
Configures the operation of INT, CFAULT, etc. for a fault on  
Analog Channel 1.  
AIN0 Event Mask  
Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed  
in response to a fault on Channel 0.  
AIN1 Event Mask  
Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed  
in response to a fault on Channel 1.  
60  
61  
68  
69  
70  
71  
78  
79  
80  
Fan 1 Minimum/Alarm Speed  
Fan 2 Minimum/Alarm Speed  
Fan 1 Configuration  
Fan 2 Configuration  
Fan 1 Tach Value  
FFh  
FFh  
2Fh  
2Fh  
00h  
00h  
FFh  
FFh  
??h  
Contains the Minimum/Alarm speeds for Fan 1.  
Contains the Minimum/Alarm speeds for Fan 2.  
Configures hot-plug speed, PWM and tach frequency.  
Configures hot-plug speed, PWM and tach frequency.  
Contains the measured value from the FAN 1 tachometer output.  
Contains the measured value from the FAN 2 tachometer output.  
Contains the high limit for FAN 1 tachometer measurement.  
Contains the high limit for FAN 2 tachometer measurement.  
Fan 2 Tach Value  
Fan 1 Tach High Limit  
Fan 2 Tach High Limit  
Local Temp TMIN  
Defines the starting temperature for the fan when controlled  
by the local temperature channel, under Automatic Fan  
Speed Control.  
81  
82  
88  
89  
Remote 1 Temp TMIN  
??h  
Defines the starting temperature for the fan when controlled  
by the Remote 1 temperature channel, under Automatic Fan  
Speed Control. (D1 Temp Sensor).  
Remote 2 Temp TMIN  
??h  
Defines the starting temperature for the fan when controlled  
by the Remote 2 temperature channel, under Automatic Fan  
Speed Control. (D2 Temp Sensor).  
Local Temp TRANGE/THYST  
Remote 1 Temp TRANGE/THYST  
51h  
51h  
This register programs the control range for the local tempera-  
ture control loop. It also defines the amount of temperature  
hysteresis applied to the loop.  
This register programs the control range for the Remote 1  
temperature control loop. It also defines the amount of tem-  
perature hysteresis applied to the loop.  
Rev. 1 | Page 30 of 50 | www.onsemi.com  
ADM1029  
Table X. Register Map (Continued)  
Address  
Name  
Default Value  
Description  
8A  
Remote 2 Temp TRANGE/THYST  
51h  
This register programs the control range for the Remote 2  
temperature control loop. It also defines the amount of tem-  
perature hysteresis applied to the loop.  
90  
91  
92  
98  
99  
9A  
A0  
A1  
A2  
A8  
A9  
B0  
B1  
B8  
B9  
Local Temp High Limit  
Remote 1 Temp High Limit  
Remote 2 Temp High Limit  
Local Temp Low Limit  
Remote 1 Temp Low Limit  
Remote 2 Temp Low Limit  
Local Temp Value  
50h (80°C)  
64h (100°C)  
64h (100°C)  
3Ch (60°C)  
46h (70°C)  
46h (70°C)  
00h  
High limit for Local measurement (internal sensor).  
High limit for Remote 1 measurement (D1 Sensor).  
High limit for Remote 2 measurement (D2 Sensor).  
Low limit for Local Temp measurement (internal sensor).  
Low limit for Remote 1 measurement (D1 Sensor).  
Low limit for Remote 2 measurement (D2 Sensor).  
Measured value from local temp sensor.  
Remote 1 Temp Value  
Remote 2 Temp Value  
AIN0 High Limit  
00h  
Measured value from D1 Remote Sensor.  
00h  
Measured value from D2 Remote Sensor.  
FFh  
High limit for measurement on analog Channel 0.  
High limit for measurement on analog Channel 1.  
Low limit for measurement on analog Channel 0.  
Low limit for measurement on analog Channel 1.  
Measured value of analog Channel 0.  
AIN1 High Limit  
FFh  
AIN0 Low Limit  
00h  
AIN1 Low Limit  
00h  
AIN0 Measured Value  
AIN1 Measured Value  
00h  
00h  
Measured value of analog Channel 1.  
NOTE  
Question marks on this and following pages indicate bit settings that depend on the state of certain pins on power-up.  
Rev. 1 | Page 31 of 50 | www.onsemi.com  
ADM1029  
CONFIGURATION REGISTERS  
Register 01h — Config Register (Power-On Default 000? 000?)  
Bit  
Name  
R/W  
Description  
0
1
2
3
Install = ?  
R/W  
R/W  
R/W  
R/W  
This bit reflects Bit 1 of Register 0x03 (Fans Supported In System).  
Setting this bit to 1 will disable the INT output for all interrupt sources.  
Setting this bit to 1 will disable the SMBus Alert Response Address feature.  
Global INT mask = 0  
ARA Disable = 0  
Perform Free-Wheel  
Test = 0  
Setting this bit to 1 will initiate the Fan Free-Wheeling Test. While this test  
is being performed normal monitoring of fan speeds, temperature and volt-  
ages will be temporarily halted. This bit will automatically reset to 0 once the  
test is complete which will take about 10 seconds.  
4
Start Monitoring = 0  
R/W  
Set to 1 to start round robin monitoring cycle of voltage temperature and fan  
speeds, fault detection, etc. While this bit is 0, all fans will run at Alarm  
Speed. This bit is set at power-up; otherwise, if automatic fan speed control  
is enabled by Pin 18.  
5
6
7
Force CFAULT = 0  
Force INT = 0  
R/W  
R/W  
R/W  
Setting this bit to 1 forces CFAULT to be asserted (Low).  
Setting this bit to 1 forces INT to be asserted (Polarity depends on Bit 7).  
Polarity of INT when asserted. 1 means High and 0 means Low.  
INT Polarity = 0  
NOTE  
Question marks on this and following pages indicate bit settings that depend on the state of certain pins on power-up.  
Register 05h – GPIO Present / AIN (Power-On Default 0????111)  
Bit  
Name  
R/W  
Description  
0
GPIO 0 = 1  
R/W  
Indicates that GPIO0 is being used. Set to 1 on power-up, but can be over-  
written by software. Setting this bit to 0 means AIN0 is being used.  
1
2
3
GPIO 1 = 1  
GPIO 2 = 1  
GPIO 3 = ?  
R/W  
R/W  
R/W  
Indicates that GPIO1 is being used. Set to 1 on power-up, but can be over-  
written by software. Setting this bit to 0 means AIN1 is being used.  
Indicates that GPIO2 is being used. Set to 1 on power-up, but can be over-  
written by software.  
Indicates that GPIO3 is being used. Setting this bit to 0 means TDM1 is  
being used. The ADM1029 can detect on power-up if TDM1 is connected.  
If so, this bit is set to 0, otherwise it is set to 1. The default setting can be  
overwritten by software.  
4
5
6
GPIO 4 = ?  
GPIO 5 = ?  
GPIO 6 = ?  
Reserved  
R/W  
R/W  
R/W  
R
Indicates that GPIO4 is being used. Setting this bit to 0 means TDM1 is  
being used. The ADM1029 can detect on power-up if TDM1 is connected.  
If so, this bit is set to 0, otherwise it is set to 1. The default setting can be  
overwritten by software.  
Indicates that GPIO5 is being used. Setting this bit to 0 means TDM2 is  
being used. The ADM1029 can detect on power-up if TDM2 is connected.  
If so, this bit is set to 0, otherwise it is set to 1. The default setting can be  
overwritten by software.  
Indicates that GPIO6 is being used. Setting this bit to 0 means TDM2 is  
being used. The ADM1029 can detect on power-up if TDM2 is connected.  
If so, this bit is set to 0, otherwise it is set to 1. The default setting can be  
overwritten by software.  
7
Unused. Will read back 0.  
NOTE  
Question marks on this and following pages indicate bit settings that depend on the state of certain pins on power-up.  
Rev. 1 | Page 32 of 50 | www.onsemi.com  
ADM1029  
Register 07h – Set Fan x* Alarm Speed (Power-On Default 00h)  
Bit  
Name  
R/W  
Description  
0
1
2
3
4
5
6
7
Fan 1 Alarm Speed = 0  
Fan 2 Alarm Speed = 0  
Reserved  
R/W  
R/W  
R
When set to 1, Fan 1 will run at Alarm Speed.  
When set to 1, Fan 2 will run at Alarm Speed.  
Unused. Will read back 0.  
Reserved  
R
Unused. Will read back 0.  
Reserved  
R
Unused. Will read back 0.  
Reserved  
R
Unused. Will read back 0.  
Reserved  
R
Unused. Will read back 0.  
Reserved  
R
Unused. Will read back 0.  
NOTES  
*“x” denotes the fan number.  
Question marks on this and following pages indicate bit settings that depend on the state of certain pins on power-up.  
Register 08h – Set Fan x* Hot-Plug Speed (Power-On Default 00h)  
Bit  
Name  
R/W  
Description  
0
1
2
3
4
5
6
7
Fan 1 Hot-Plug Speed = 0  
R/W  
R/W  
R
When set to 1, Fan 1 will run at Hot-Plug Speed.  
When set to 1, Fan 2 will run at Hot-Plug Speed.  
Unused. Will read back 0.  
Fan 2 Hot-Plug Speed = 0  
0
0
0
0
0
0
R
Unused. Will read back 0.  
R
Unused. Will read back 0.  
R
Unused. Will read back 0.  
R
Unused. Will read back 0.  
R
Unused. Will read back 0.  
NOTES  
*“x” denotes the fan number.  
Question marks on this and following pages indicate bit settings that depend on the state of certain pins on power-up.  
Register 09h – Set Fan x* Full Speed (Power-On Default 00h)  
Bit  
Name  
R/W  
Description  
0
1
2
3
4
5
6
7
Fan 1 Full Speed = 0  
Fan 2 Full Speed = 0  
Reserved  
R/W  
R/W  
R
When set to 1 Fan 1 will run at Full Speed.  
When set to 1 Fan 2 will run at Full Speed.  
Unused. Will read back 0.  
Reserved  
R
Unused. Will read back 0.  
Reserved  
R
Unused. Will read back 0.  
Reserved  
R
Unused. Will read back 0.  
Reserved  
R
Unused. Will read back 0.  
Reserved  
R
Unused. Will read back 0.  
NOTES  
*“x” denotes the fan number.  
Question marks on this and following pages indicate bit settings that depend on the state of certain pins on power-up.  
Rev. 1 | Page 33 of 50 | www.onsemi.com  
ADM1029  
STATUS REGISTERS  
Register 00h – Status Register (Power-On Default 00h)  
Bit  
Name  
R/W  
Description  
0
INT  
R
This bit is set to 1 when the device is asserting INT low. This bit is the logical  
OR of several bits in other registers and is cleared when these bits are cleared.  
1
2
CFAULT_in  
R
R
This bit is set to 1 when the device is receiving CFAULT low from another device.  
CFAULT_out  
This bit is set to 1 when the device is asserting CFAULT low. This bit is  
the logical OR of several bits in other registers and is cleared when these  
bits are cleared.  
3
4
5
In Alarm_speed  
R
R
R
This bit is set to 1 when either fan is running at Alarm Speed. This bit is the  
logical OR of several bits in other registers and is cleared when these bits are  
cleared.  
In Hot-Plug Speed  
GPIO/AIN Event  
This bit is set to 1 when either fan is running at Hot-Plug Speed. This bit is  
the logical OR of several bits in other registers and is cleared when these bits  
are cleared.  
This bit is a logical OR of Bits 1, 3, 6, and 7 in the GPIO Behavior Registers  
at 28h to 2Eh while they are configured as inputs, and Bit 7 in the AIN  
Behavior Registers at 50h and 51h. It will be set when any of these bits are set  
and cleared when all of these bits are cleared.  
6
7
Hot Plug/Fan Fault  
Thermal Event  
R
R
This bit is a logical OR of Bits 1, 3, 6, and 7 in the Fan Status Registers at  
10h and 11h. It will be set when any of these bits are set and cleared when all  
of these bits are cleared.  
This bit is a logical OR of Bit 7 in the Temp Fault Action Registers at 40h,  
41h, and 42h. It will be set when any of these bits are set and cleared when all  
of these bits are cleared.  
Register 02h – Fan Supported By Controller (Power-On Default 03h)  
Bit  
Name  
R/W  
Description  
0
1
2
3
4
5
6
7
Fan 1 = 1  
Fan 2 = 1  
Reserved  
Reserved  
Reserved  
Reserved  
Reserved  
Reserved  
R
R
R
R
R
R
R
R
This bit set to 1 means the ADM1029 can support Fan 1.  
This bit set to 1 means the ADM1029 can support Fan 2.  
Unused. Will read back 0.  
Unused. Will read back 0.  
Unused. Will read back 0.  
Unused. Will read back 0.  
Unused. Will read back 0.  
Unused. Will read back 0.  
Register 03h – Fans Supported In System (Power-On Default 0000 00?1)  
Bit  
Name  
R/W  
Description  
0
Fan 1 = 1  
R/W  
Indicates that Fan 1 is being used. Set to 1 on Power-up, but can be over-  
written by software.  
1
Fan 2 = ?  
R/W  
Indicates that Fan 2 is being used. Set by Pin 18 (TMIN/INSTALL) on  
Power-up, but can be overwritten by software.  
2
3
4
5
6
7
Reserved  
Reserved  
Reserved  
Reserved  
Reserved  
Reserved  
R
R
R
R
R
R
Unused. Will read back 0.  
Unused. Will read back 0.  
Unused. Will read back 0.  
Unused. Will read back 0.  
Unused. Will read back 0.  
Unused. Will read back 0.  
NOTE  
Question marks on this and following pages indicate bit settings that depend on the state of certain pins on power-up.  
Rev. 1 | Page 34 of 50 | www.onsemi.com  
ADM1029  
Register 04h – GPIOs Supported By Controller (Power-On Default 7Fh)  
Bit  
Name  
R/W  
Description  
0
GPIO 0 = 1 (Pin 19)  
R
This bit set to 1 means the ADM1029 can support GPIO0, available on  
Pin 19.  
1
2
3
4
5
6
7
GPIO 1 = 1 (Pin 20)  
GPIO 2 = 1 (Pin 11)  
GPIO 3 = 1 (Pin 13)  
GPIO 4 = 1 (Pin 14)  
GPIO 5 = 1 (Pin 16)  
GPIO 6 = 1 (Pin 17)  
Reserved  
R
R
R
R
R
R
R
This bit set to 1 means the ADM1029 can support GPIO1, available on  
Pin 20.  
This bit set to 1 means the ADM1029 can support GPIO2, available on  
Pin 11.  
This bit set to 1 means the ADM1029 can support GPIO3, available on  
Pin 13.  
This bit set to 1 means the ADM1029 can support GPIO4, available on  
Pin 14.  
This bit set to 1 means the ADM1029 can support GPIO5, available on  
Pin 16.  
This bit set to 1 means the ADM1029 can support GPIO6, available on  
Pin 17.  
Unused. Will read back 0.  
Register 06h – Temp Devices Installed (Power-On Default 0000 0??1)  
Bit  
Name  
R/W  
Description  
0
Local Temp = 1  
R
This bit is permanently set to 1 since the local temperature sensor is  
always available.  
1
2
Remote 1 Temp = ?  
Remote 2 Temp = ?  
R
R
This bit is set to 1 if the Remote 1 temperature sensor (TDM1) is installed.  
(Automatically detected on power-up.)  
This bit is set to 1 if the Remote 2 temperature sensor (TDM2) is installed.  
(Automatically detected on power-up.)  
3
4
5
6
7
Reserved  
Reserved  
Reserved  
Reserved  
Reserved  
R
R
R
R
R
Unused. Will read back 0.  
Unused. Will read back 0.  
Unused. Will read back 0.  
Unused. Will read back 0.  
Unused. Will read back 0.  
NOTE  
Question marks on this and following pages indicate bit settings that depend on the state of certain pins on power-up.  
Rev. 1 | Page 35 of 50 | www.onsemi.com  
ADM1029  
Register 10h, 11h – Fan x* Status (Power-On Default 0000 0?0?)  
Bit  
Name  
R/W  
Description  
0
Missing = x  
R
Reflects the state of Pins 4/21. Low means Fan x* is installed, High  
means it is missing. This bit will automatically return Low if a missing  
fan is replaced.  
1
2
Missing _L = 0  
Fault_ = x  
R/W  
R
This bit is edge-triggered and latches a Fan x* missing event on removal  
of Fan x. This bit is cleared by writing a 0 to it.  
Inverse of Pin 2/23. Low on pin means Fan x* has a fault (Pins 2/23  
Low), High on pin means it is OK. This bit will automatically return  
Low if Pins 2/23 goes high.  
3
4
Fault_L_ = 0  
Sleep = 0  
R/W  
R/W  
This bit is edge-triggered and latches a Fan x* fault event on Pins 2/23.  
This bit is cleared by writing a 0 to it. If the PRESENT pin for a fan  
input is high (fan not installed) this bit will be cleared automatically.  
When this bit is set, Fan x* will be stopped and no Fan x* faults will be  
monitored. If Bit 4 in Fan x* Fault Action Register is set, Fan x* will go  
to Alarm Speed if an overtemperature event is detected as per settings in  
the Temp Fault Action Registers.  
5
6
Hot Plug Priority  
Tach_Fault_L  
R/W  
R/W  
This bit indicates whether Fan x runs at Hot-Plug Speed (bit set to 1) or  
Alarm Speed (bit set to 0) if both modes are triggered.  
Latches a Fan x Tach Fault. This bit is cleared by writing a 0 to it. If the  
PRESENT pin for a fan input is high (fan not installed), this bit will be  
cleared automatically.  
7
Hot_Plug_L  
R/W  
This bit is edge-triggered and latches a Fan x Hot-plug event which is the  
insertion of Fan x. (Note difference to Bit 1.) This bit is cleared by writ-  
ing a 0 to it. If a fan is Hot-Plug installed, it will run at Normal Speed.  
NOTES  
*“x” denotes the fan number. Register 10h is for Fan 1 and Register 11h is for Fan 2.  
Question marks on this and following pages indicate bit settings that depend on the state of certain pins on power-up.  
Rev. 1 | Page 36 of 50 | www.onsemi.com  
ADM1029  
TEMPERATURE REGISTERS  
Register 06h – Temp Devices Installed (Power-On Default 0000 0??1)  
Bit  
Name  
R/W  
Description  
0
Local Temp = 1  
R
This bit is permanently set to 1 since the local temperature sensor is always  
available.  
1
2
Remote 1 Temp = ?  
Remote 2 Temp = ?  
R
R
This bit is set to 1 if the Remote 1 temperature sensor (TDM1) is installed.  
(Automatically detected on power-up.)  
This bit is set to 1 if the Remote 2 temperature sensor (TDM2) is installed.  
(Automatically detected on power-up.)  
3
4
5
6
7
Reserved  
Reserved  
Reserved  
Reserved  
Reserved  
R
R
R
R
R
Unused. Will read back 0.  
Unused. Will read back 0.  
Unused. Will read back 0.  
Unused. Will read back 0.  
Unused. Will read back 0.  
NOTE  
Question marks on this and following pages indicate bit settings that depend on the state of certain pins on power-up.  
Register 30h, 31h, 32h – Temp x* Offset Registers (Power-On Default 00h)  
Bit  
Name  
R/W  
Description  
<7:0>  
Offset  
R/W  
This register contains an offset value that is automatically added to the tem-  
perature value to reduce the effects of systemic offset errors.  
*“x” denotes the number of the temperature channel. Register 30h is for Local temperature channel, 31h is for Remote 1 Temp (D1), 32h is for Remote 2 Temp (D2).  
Register 40h, 41h, 42h – Temp x* Fault Action (Power-On Default 08h)  
Bit  
Name  
R/W  
Description  
0
Assert CFAULT on  
OT = 0  
R/W  
When this bit is set, CFAULT will be asserted when the Temp x* tempera-  
ture exceeds the Temp x* Temperature High Limit, not otherwise.  
1
2
3
Alarm speed on OT = 0  
INT on OT = 0  
R/W  
R/W  
R/W  
When this bit is set, the fans(s) will go to alarm speed when the Temp x*  
temperature exceeds the Temp x* Temperature High limit, not otherwise.  
When this bit is set, INT will be asserted when the Temp x* temperature  
exceeds the Temp x* Temperature High Limit, not otherwise.  
Alarm below low = 0  
This bit indicates whether an alarm (INT, CFAULT, or Alarm Speed) is  
asserted when temperature goes above or below the Low Limit. 1 = above,  
0 = below. This bit is set to 1 at power-up if automatic fan speed control is  
enabled by Pin 18, cleared otherwise.  
4
Assert CFAULT on  
UT = 0  
R/W  
When this bit is set, CFAULT will be asserted when the Temp x* temperature  
crosses the Temp x* Temperature Low Limit, not otherwise. Bit 3 decides  
whether CFAULT is asserted for going above or below the Low Limit. This bit is  
set to 1 if Automatic Fan Speed Control is enabled on power-up.  
5
6
7
Alarm speed on UT = 0  
INT on UT = 0  
R/W  
R/W  
R/W  
When this bit is set, the fans(s) will go to alarm speed when the Temp x*  
temperature crosses the Temp x* Temperature Low Limit, not otherwise. Bit  
3 decides whether Alarm Speed is asserted for going above or below the Low Limit.  
When this bit is set, INT will be asserted when the Temp x* temperature  
crosses the Temp x* Temperature Low Limit, not otherwise. Bit 3 decides  
whether INT is asserted for going above or below the Low Limit.  
Latch Temp Fault = 0  
This bit latches a temperature out-of-limit event (i.e., when the temperature  
goes above the high limit or crosses the low limit) on the Temp x* channel.  
This bit is cleared by writing a 0 to it.  
*“x” denotes the number of the temperature channel. Register 40h is for the Local temperature channel, 41h is for Remote 1 Temp (D1), 42h is for Remote 2  
Temp (D2).  
Rev. 1 | Page 37 of 50 | www.onsemi.com  
ADM1029  
Register 48h, 49h, 4Ah – Temp x* Cooling Action (Power-On Default 00h)  
Bit  
Name  
R/W  
Description  
0
Fan 1 = 0  
R/W  
If a Temp x* out-of-limit event is generated such that fans should be driven at  
Alarm Speed, Fan 1 will be set to this speed when this bit is set. If no Temp x*  
out-of-limit event is present, Fan 1 will be set to the speed determined by the  
automatic fan speed control circuit as a result of temperature measurements on  
the Temp x* channel when this bit is set. If this bit is not set, Temp x* tem-  
perature measurements will have no effect on the speed of Fan 1.  
1
Fan 2 = 0  
R/W  
If a Temp x* out-of-limit event is generated such that fans should be driven  
at Alarm Speed, Fan 2 will be set to this speed when this bit is set. If no Temp  
x* out-of-limit event is present, Fan 2 will be set to the speed determined by  
the automatic fan speed control circuit as a result of temperature measure-  
ments on the Temp x* channel when this bit is set. If this bit is not set,  
Temp x temperature measurements have no effect on the speed of Fan 2.  
While in theory it is possible, through setting of Bits 0 and 1 in registers 48h  
to 4Ah, to have any temperature channel controlling any fan, in practice this  
is not feasible. A subset of possibilities only are supported as follows:  
Case 1:  
TDM1 controlling Fan 1  
(Bit 0 in 49h set and/or  
TDM2 controlling Fan 2  
Bit 1 in 4Ah set, only)  
Case 2:  
Case 3:  
Case 4:  
Case 5:  
Local controlling Fan 1 and/or Fan 2 (Bits 0, 1 in 48h only set)  
TDM1 controlling Fan 1 and/or Fan 2 (Bits 0, 1 in 49h only set)  
TDM2 controlling Fan 1 and/or Fan 2 (Bits 0, 1 in 4Ah only set)  
Fan 1 and/or Fan 2 set to max speed (Bits 0, 1 in 48h, 49h,  
(Default) determined by temperature  
measurements on all three channels.  
4Ah all set)  
Other:  
If Bits 0,1 in registers 48h, 49h, 4Ah are  
set inconsistent with these cases, fans  
will run at the speeds determined by  
the normal speed registers.  
2
3
4
5
6
7
Reserved  
Reserved  
Reserved  
Reserved  
Reserved  
Reserved  
R
R
R
R
R
R
Unused. Will read back 0.  
Unused. Will read back 0.  
Unused. Will read back 0.  
Unused. Will read back 0.  
Unused. Will read back 0.  
Unused. Will read back 0.  
*“x” denotes the number of the temperature channel. Register 48h is for the Local temperature channel. 49h is for Remote 1 Temp (D1), 4Ah is for Remote 2  
Temp (D2).  
Rev. 1 | Page 38 of 50 | www.onsemi.com  
ADM1029  
Register 80h, 81h, 82h – Temp x* TMIN (Power-On Default 001??000)  
Bit  
Name  
R/W  
Description  
<7:0>  
Temp x* TMIN  
R/W  
This register contains the minimum temperature value for automatic fan speed  
control based on the Temp x* temperature. On power-up Pin 18 is sampled  
by the ADC to determine the default value for Temp x* TMIN. If Pin 18 is  
strapped to GND or VCC, this register defaults to 32°C, but Automatic Fan  
Speed Control is disabled. There are eight strappable options on Pin 18.  
These options are used to set Temp x* TMIN and the Install bit in the Config  
Register (Reg 01h, Bit 0). The options are as follows:  
ADC MSBs R1  
R2  
Install  
Temp x* TMIN  
111  
101  
110  
100  
011  
010  
001  
000  
0
1
1
1
1
0
0
0
0
Disabled  
48°C  
40°C  
18 k82 kΩ  
22 k47 kΩ  
12 k15 kΩ  
15 k12 kΩ  
47 k22 kΩ  
82 k18 kΩ  
32°C  
32°C  
40°C  
48°C  
Disabled  
0
*“x” denotes the number of the temperature channel. Register 80h is for the Local temperature channel, 81h is for Remote 1 Temp (D1), 82h is for Remote 2  
Temp (D2).  
Register 88h, 89h, 8Ah Temp x* TRANGE/THYST (Power-On Default 51h)  
Bit  
Name  
R/W  
Description  
<3:0>  
Temp x* TRANGE  
R/W  
This nibble contains the temperature range over which automatic fan speed  
control operates based on the Temp x* measured temperature. Only a limited  
number of temperature ranges are supported as follows:  
Bits <3:0>  
TRANGE  
0000  
0001  
0010  
0011  
0100  
5°C  
10°C  
20°C  
40°C  
80°C  
<7:4>  
Temp x* THYST  
R/W  
This nibble allows programmability of the Hysteresis level around the temperature  
at which the fan being controlled by Temp x* will switch on in automatic fan  
speed control mode. Values from 0°C to 15°C are possible. If a value other than  
0°C is programmed as a Hysteresis value, the fan will switch on when Temp x*  
goes above TMIN, but will remain on until Temp x* falls below TMIN–THYST.  
Between TMIN–THYST and TMIN the fan will run at the programmed minimum  
pulsewidth in the Fan x* Speed 1 register.  
*“x” denotes the number of the temperature channel. Register 88h is for the Local temperature channel, 89h is for Remote 1 Temp (D1), 8Ah is for Remote 2 Temp (D2).  
Rev. 1 | Page 39 of 50 | www.onsemi.com  
ADM1029  
Register 90h, 91h, 92h – Temp x* High Limit (Power-On Default 80؇C for Local Sensor, 100؇C for Remote Sensors)  
Bit  
Name  
R/W  
Description  
This register contains the high limit value for the Temp x* measurement.  
<7:0>  
Temp x* High Limit  
R/W  
*“x” denotes the number of the temperature channel. Register 90h is for the Local temperature channel. 91h is for Remote 1 Temp (D1), 92h is for Remote 2  
Temp (D2).  
Register 98h, 99h, 9Ah – Temp x* Low Limit (Power-On Default 60؇C for Local Sensor, 70؇C for Remote Sensors)  
Bit  
Name  
R/W  
Description  
<7:0>  
Temp x* Low Limit  
R/W  
This register contains the low limit value for the Temp x* measurement.  
*“x” denotes the number of the temperature channel. Register 98h is for the Local temperature channel. 99h is for Remote 1 Temp (D1), 9Ah is for Remote 2  
Temp (D2).  
Register A0h, A1h, A2h – Temp x* Measured Value (Power-On Default 00h)  
Bit  
Name  
R/W  
Description  
<7:0>  
Temp x* Value  
R
This register contains the actual Temp x* measured value.  
*“x” denotes the number of the temperature channel. Register A0h is for the Local temperature channel. A1h is for Remote 1 Temp (D1), A2h is for Remote 2  
Temp (D2).  
Rev. 1 | Page 40 of 50 | www.onsemi.com  
ADM1029  
FAN REGISTERS  
Register 02h – Fan Supported By Controller (Power-On Default 03h)  
Bit  
Name  
R/W  
Description  
0
1
2
3
4
5
6
7
Fan 1 = 1  
Fan 2 = 1  
Reserved  
Reserved  
Reserved  
Reserved  
Reserved  
Reserved  
R
R
R
R
R
R
R
R
This bit set to 1 means the ADM1029 can support Fan 1.  
This bit set to 1 means the ADM1029 can support Fan 2.  
Unused. Will read back 0.  
Unused. Will read back 0.  
Unused. Will read back 0.  
Unused. Will read back 0.  
Unused. Will read back 0.  
Unused. Will read back 0.  
Register 03h – Fans Supported In System (Power-On Default 0000 00?1)  
Bit  
Name  
R/W  
Description  
0
Fan 1 = 1  
R/W  
Indicates that Fan 1 is being used. Set to 1 on power-up, but can be overwrit-  
ten by software.  
1
Fan 2 = ?  
R/W  
Indicates that Fan 2 is being used. Set by Pin 18 (TMIN/INSTALL) on  
power-up, but can be overwritten by software.  
2
3
4
5
6
7
Reserved  
Reserved  
Reserved  
Reserved  
Reserved  
Reserved  
R
R
R
R
R
R
Unused. Will read back 0.  
Unused. Will read back 0.  
Unused. Will read back 0.  
Unused. Will read back 0.  
Unused. Will read back 0.  
Unused. Will read back 0.  
NOTE  
Question marks on this and following pages indicate bit settings that depend on the state of certain pins on power-up.  
Register 07h – Set Fan x Alarm Speed (Power-On Default 00h)  
Bit  
Name  
R/W  
Description  
0
1
2
3
4
5
6
7
Fan 1 Alarm Speed = 0  
Fan 2 Alarm Speed = 0  
Reserved  
R/W  
R/W  
R
When set to 1, Fan 1 will run at Alarm Speed.  
When set to 1, Fan 2 will run at Alarm Speed.  
Unused. Will read back 0.  
Reserved  
R
Unused. Will read back 0.  
Reserved  
R
Unused. Will read back 0.  
Reserved  
R
Unused. Will read back 0.  
Reserved  
R
Unused. Will read back 0.  
Reserved  
R
Unused. Will read back 0.  
Register 08h – Set Fan x Hot-Plug Speed (Power-On Default 00h)  
Bit  
Name  
R/W  
Description  
0
1
2
3
4
5
6
7
Fan 1 Hot-Plug Speed = 0  
R/W  
R/W  
R
When set to 1, Fan 1 will run at Hot-Plug Speed.  
When set to 1, Fan 2 will run at Hot-Plug Speed.  
Unused. Will read back 0.  
Fan 2 Hot-Plug Speed = 0  
0
0
0
0
0
0
R
Unused. Will read back 0.  
R
Unused. Will read back 0.  
R
Unused. Will read back 0.  
R
Unused. Will read back 0.  
R
Unused. Will read back 0.  
Rev. 1 | Page 41 of 50 | www.onsemi.com  
ADM1029  
Register 09h – Set Fan x Full Speed (Power-On Default 00h)  
Bit  
Name  
R/W  
Description  
0
1
2
3
4
5
6
7
Fan 1 Full Speed = 0  
Fan 2 Full Speed = 0  
Reserved  
R/W  
R/W  
R
When set to 1 Fan 1 will run at Full Speed.  
When set to 1 Fan 2 will run at Full Speed.  
Unused. Will read back 0.  
Reserved  
R
Unused. Will read back 0.  
Reserved  
R
Unused. Will read back 0.  
Reserved  
R
Unused. Will read back 0.  
Reserved  
R
Unused. Will read back 0.  
Reserved  
R
Unused. Will read back 0.  
Register 0Ch – Fan Spin-Up Register (Power-On Default 03h)  
Bit  
Name  
R/W  
Description  
<7:4>  
3
Reserved  
R
Unused  
Spin-up Disable  
Fan Spin-up Time  
R/W  
R/W  
When this bit is set to 1, fan spin-up to full speed will be disabled.  
<2:0>  
These bits select the spin-up time for the fans  
000 = 16 seconds  
001 = 8 seconds  
010 = 4 seconds  
011 = 2 seconds (default)  
100 = 1 second  
101 = 0.25 seconds  
110 = 1/16 second  
111 = 1/64 second  
Register 10h, 11h – Fan x* Status (Power-On Default 0000 0?0?)  
Bit  
Name  
R/W  
Description  
0
Missing = x  
R
Reflects the state of Pins 4/21. Low means Fan x* is installed, High means it  
is missing. This bit will automatically return Low if a missing fan is replaced.  
1
2
Missing _L = 0  
Fault_ = x  
R/W  
R
This bit is edge-triggered and latches a Fan x* missing event on removal of  
Fan x*. This bit is cleared by writing a 0 to it.  
Inverse of Pin 2/23. Low on pin means Fan x* has a fault (Pins 2/23 Low),  
High on pin means it is OK. This bit will automatically return Low if Pin 2/23  
goes high.  
3
4
Fault_L_ = 0  
Sleep = 0  
R/W  
R/W  
This bit is edge-triggered and latches a Fan x* fault event on Pin 2/23. This bit  
is cleared by writing a 0 to it. If the PRESENT pin for a fan input is high (fan  
not installed) this bit will be cleared automatically.  
When this bit is set, Fan x* will be stopped and no Fan x* faults will be  
monitored. If Bit 4 in Fan x* Fault Action Register is set then Fan x* will go  
to Alarm Speed if an overtemperature event is detected as per settings in the  
Temp Fault Action Registers.  
5
6
Hot Plug Priority  
Tach_Fault_L  
R/W  
R/W  
This bit indicates whether Fan x* runs at Hot-Plug Speed (bit set to 1) or  
Alarm Speed (bit set to 0) if both modes are triggered.  
Latches a Fan x* Tach fault. This bit is cleared by writing a 0 to it. If the  
PRESENT pin for a fan input is high (fan not installed) this bit will be  
cleared automatically.  
7
Hot_Plug_L  
R/W  
This bit is edge-triggered and latches a Fan x* Hot-Plug event which is the  
insertion of Fan x*. (Note difference to Bit 1) This bit is cleared by writing a 0  
to it. If a fan is Hot-Plug installed, it will run at Normal Speed.  
NOTES  
*“x” denotes the fan number. Register 10h is for Fan 1 and Register 11h is for Fan 2.  
Question marks on this and following pages indicate bit settings that depend on the state of certain pins on power-up.  
Rev. 1 | Page 42 of 50 | www.onsemi.com  
ADM1029  
Register 18h, 19h – Fan x* Fault Action (Power-On Default BFh)  
Bit  
Name  
R/W  
Description  
0
Assert CFAULT on  
Fault = 1  
R/W  
If this bit is set, CFAULT will be asserted when there is a fault (Tach or  
Pins 2/23) on Fan x*.  
1
2
3
4
Assert INT on Fault = 1  
R/W  
R/W  
R/W  
R/W  
If this bit is set, INT will be asserted when there is a fault (Tach or Pins 2  
23) on Fan x*.  
Assert CFAULT on  
Hot Unplug = 1  
If this bit is set, CFAULT will be asserted when there is a hot unplug event  
on Fan x*.  
Assert INT on  
Hot Unplug = 1  
If this bit is set, INT will be asserted when there is a hot unplug event  
on Fan x*.  
Thermal Override in  
Sleep = 1  
If Bit 4 in Fan x* Status Register is set then Fan x* will go to Alarm Speed if  
an overtemperature event is detected as per settings in Temp x* Fault Action  
Registers, while this bit is set.  
5
6
7
Drive Fault_ on  
Fault_L = 1  
R/W  
R/W  
R/W  
If Bit 3 or Bit 6 of Reg 10 is set, drive Pins 2, 23 low if a fault is generated.  
Hot-Plug Speed on  
CFAULT in = 0  
When this bit is set, Fan x* will go to Hot-Plug Speed when CFAULT is  
pulled low externally.  
Alarm on CFAULT = 1  
When this bit is set, Fan x* will go to Alarm Speed when CFAULT is pulled  
low externally.  
*“x” denotes the fan number. Register 18h is for Fan 1 and Register 19h is for Fan 2.  
Register 20h, 21h – Fan x* Event Mask (Power-On Default FFh)  
Bit  
Name  
R/W  
Description  
0
Fan 1 = 1  
R/W  
If a fault (Tach or Pins 2/23) is detected on Fan x*, Fan 1 will be driven to  
Alarm Speed when this bit is set.  
1
Fan 2 = 1  
R/W  
If a fault (Tach or Pins 2/23) is detected on Fan x*, Fan 2 will be driven to  
Alarm Speed when this bit is set.  
2
3
4
5
6
7
Reserved  
Reserved  
Reserved  
Reserved  
Reserved  
Reserved  
R
R
R
R
R
R
Unused. Will read back 1.  
Unused. Will read back 1.  
Unused. Will read back 1.  
Unused. Will read back 1.  
Unused. Will read back 1.  
Unused. Will read back 1.  
*“x” denotes the fan number. Register 20h is for Fan 1 and Register 21h is for Fan 2.  
Register 60h, 61h – Fan x* Minimum/Alarm Speed (Power-On Default FFh)  
Bit  
Name  
R/W  
Description  
3–0  
Fan x Minimum Speed  
R/W  
This nibble contains the Normal speed value for Fan x*. When in automatic  
fan this nibble will contain the minimum speed at which Fan x* will run. The  
power-up default for the Min Speed should be 5hex which corresponds to  
33% PWM duty cycle.  
7–4  
Fan x Alarm Speed  
R/W  
This nibble contains the Alarm speed value for Fan x*.  
*“x” denotes the fan number. Register 60h is for FAN 1 and 61h is for FAN 2.  
Rev. 1 | Page 43 of 50 | www.onsemi.com  
ADM1029  
Register 68h, 69h – Fan x* Configuration (Power-On Default 2Fh)  
Bit  
Name  
R/W  
Description  
<3:0>  
Fan x* Hot-Plug Speed  
R/W  
This nibble contains the Hot-Plug speed value for Fan x*. This is the speed  
the other fan(s) runs at if Fan x* is Hot-Plug removed. If a fan is Hot-Plug  
installed, it will run at Normal Speed.  
<5:4>  
PWM Frequency  
R/W  
These bits allow programmability of the Nominal PWM Frequency for  
Fan x*. The following options are supported:  
Bits 5–4  
00  
01  
PWM Freq  
15.625 Hz  
62.5 Hz  
10  
11  
250 Hz – Default  
1000 Hz  
<7:6>  
Oscillator Frequency  
R/W  
These bits contain the oscillator frequency for the Fan x* tach measurement.  
If set to 00, tach measurement is disabled for Fan x*.  
Bit 7  
Bit 6 Oscillator Frequency (Hz)  
0
0
1
1
0
1
0
1
Measurement disabled  
470  
940  
1880  
*“x” denotes the fan number. Register 68h is for FAN 1 and 69h is for FAN 2.  
Register 70h, 71h – Fan x* Tach Value (Power-On Default 00h)  
Bit  
Name  
R/W  
Description  
This register contains the value of the Fan x* tachometer measurement.  
<7:0>  
Fan x* Tach Value  
R
*“x” denotes the fan number. Register 70h is for FAN 1 and 71h is for FAN 2.  
Register 78h, 79h – Fan x* Tach High Limit (Power-On Default FFh)  
Bit  
Name  
R/W  
Description  
<7:0>  
Fan x* Tach High Limit  
R/W  
This register contains the limit value for the Fan x* tachometer measure-  
ment. Since the tachometer circuit counts between tach pulses, a slow fan will  
result in a larger measured value, so exceeding the limit is the way to detect a  
slow or stopped fan.  
*“x” denotes the fan number. Register 78h is for FAN 1 and 79h is for FAN 2.  
Rev. 1 | Page 44 of 50 | www.onsemi.com  
ADM1029  
GPIO REGISTERS  
Register 04h–GPIOs Supported by Controller (Power-On Default 7Fh)  
Bit  
Name  
R/W  
Description  
0
1
2
3
4
5
6
7
GPIO 0 = 1 (Pin 19)  
GPIO 1 = 1 (Pin 20)  
GPIO 2 = 1 (Pin 11)  
GPIO 3 = 1 (Pin 13)  
GPIO 4 = 1 (Pin 14)  
GPIO 5 = 1 (Pin 16)  
GPIO 6 = 1 (Pin 17)  
Reserved  
R
R
R
R
R
R
R
R
This bit set to 1 means the ADM1029 can support GPIO0, available on Pin 19.  
This bit set to 1 means the ADM1029 can support GPIO1, available on Pin 20.  
This bit set to 1 means the ADM1029 can support GPIO2, available on Pin 11.  
This bit set to 1 means the ADM1029 can support GPIO3, available on Pin 13.  
This bit set to 1 means the ADM1029 can support GPIO4, available on Pin 14.  
This bit set to 1 means the ADM1029 can support GPIO5, available on Pin 16.  
This bit set to 1 means the ADM1029 can support GPIO6, available on Pin 17.  
Unused. Will read back 0.  
Register 05h–GPIO Present/AIN (Power-On Default 0????111)  
Bit  
Name  
R/W  
Description  
0
GPIO 0 = 1  
R/W  
Indicates that GPIO0 is being used. Set to 1 on power-up, but can be over-  
written by software. Setting this bit to 0 means AIN0 is being used.  
1
2
3
GPIO 1 = 1  
GPIO 2 = 1  
GPIO 3 = ?  
R/W  
R/W  
R/W  
Indicates that GPIO1 is being used. Set to 1 on power-up, but can be over-  
written by software. Setting this bit to 0 means AIN1 is being used.  
Indicates that GPIO2 is being used. Set to 1 on power-up, but can be over-  
written by software.  
Indicates that GPIO3 is being used. Setting this bit to 0 means TDM1 is  
being used. The ADM1029 can detect on power-up if TDM1 is connected. If  
so then this bit is set to 0, otherwise it is set to 1. The default setting can be  
overwritten by software.  
4
5
6
GPIO 4 = ?  
GPIO 5 = ?  
R/W  
R/W  
Indicates that GPIO4 is being used. Setting this bit to 0 means TDM1 is  
being used. The ADM1029 can detect on power-up if TDM1 is connected. If  
so then this bit is set to 0, otherwise it is set to 1. The default setting can be  
overwritten by software.  
Indicates that GPIO5 is being used. Setting this bit to 0 means TDM2 is  
being used. The ADM1029 can detect on power-up if TDM2 is connected. If  
so then this bit is set to 0, otherwise it is set to 1. The default setting can be  
overwritten by software.  
GPIO 6 = ?  
Reserved  
R/W  
R
Indicates that GPIO6 is being used. Setting this bit to 0 means TDM2 is  
being used. The ADM1029 can detect on power-up if TDM2 is connected. If  
so then it is set to 1. The default setting can be overwritten by software.  
7
Unused. Will read back 0.  
NOTE  
Question marks on this and following pages indicate bit settings that depend on the state of certain pins on power-up.  
Rev. 1 | Page 45 of 50 | www.onsemi.com  
ADM1029  
Register 28h, 29h, 2Ah, 2Bh, 2Ch, 2Dh, 2Eh – GPIOx* Behavior (Power-On Default 00h)  
Bit  
Name  
R/W  
Description  
0
Direction = 0  
R/W  
This bit indicates the direction for GPIOx* pin. When set to 1 GPIOx* will  
function as an input, when 0 GPIOx* will function as an output.  
1
2
Polarity = 0  
Bit 2 = 0  
R/W  
R/W  
This bit indicates the polarity of the GPIOx* pin. When set to 1 GPIOx* will  
be active high, when 0 GPIOx* will be active low.  
If GPIOx* is configured as an input, CFAULT will be asserted if GPIOx*  
pin is asserted while this bit is set. If GPIO2 is configured as an output, GPIO2  
will be asserted if a temperature High limit is exceeded while this bit is set. If  
automatic fan speed control is enabled, this bit will be set by default. This can  
be used as a SHUTDOWN signal for a catastrophic overtemperature event.  
3
4
5
Bit 3 = 0  
Bit 4 = 0  
Bit 5 = 0  
R/W  
R/W  
R/W  
If GPIOx* is configured as an input, INT will be asserted if GPIOx* pin is  
asserted while this bit is set. If GPIOx* is configured as an output, GPIOx*  
will be asserted if a temperature Low limit is exceeded while this bit is set.  
If GPIOx* is configured as an input, Fans will go to Alarm Speed if GPIOx*  
pin is asserted while this bit is set. If GPIOx* is configured as an output,  
GPIOx* will be asserted if a Fan Tach limit is exceeded while this bit is set.  
If GPIOx* is configured as an input, Fans will go to Hot-Plug Speed if  
GPIOx* pin is asserted while this bit is set. If GPIOx* is configured as an  
output, GPIOx* will be asserted if a Fan Fault (Pins 2/23) is detected  
while this bit is set.  
6
7
Bit 6 = 0  
Bit 7 = 0  
R
R/W  
If GPIOx* is configured as an input, this bit will reflect state of GPIOx* pin.  
If GPIOx* is configured as an output, GPIOx will be asserted if an AIN high  
limit is exceeded while this bit is set.  
R/W  
If GPIOx* is configured as an input, this bit will latch a GPIOx* assertion  
event. This bit is cleared by writing a 0 to it. If GPIOx* is configured as an  
output, GPIOx* will be asserted if an AIN Low limit is exceeded while this  
bit is set.  
*“x” denotes the number of the GPIO pin. Register 28h controls GPIO0, 29h controls GPIO1, etc.  
Register 38h, 39h, 3Ah, 3Bh, 3Ch, 3Dh, 3Eh – GPIOx* Event Mask (Power-On Default 00h)  
Bit  
Name  
R/W  
Description  
0
Fan 1 = 0  
R/W  
If GPIOx* is asserted such that fans should be driven at Alarm or Hot-Plug  
Speed, Fan 1 will be set to this speed when this bit is set.  
1
Fan 2 = 0  
R/W  
If GPIOx* is asserted such that fans should be driven at Alarm or Hot-Plug  
Speed, Fan 2 will be set to this speed when this bit is set.  
2
3
4
5
6
7
Reserved  
Reserved  
Reserved  
Reserved  
Reserved  
Reserved  
R
R
R
R
R
R
Unused. Will read back 0.  
Unused. Will read back 0.  
Unused. Will read back 0.  
Unused. Will read back 0.  
Unused. Will read back 0.  
Unused. Will read back 0.  
*“x” denotes the number of the GPIO pin. Register 38h is for GPIO0, 39h is for GPIO1 etc.  
Rev. 1 | Page 46 of 50 | www.onsemi.com  
ADM1029  
AIN REGISTERS  
Register 05h – GPIO Present/AIN (Power-On Default 0????111)  
Bit  
Name  
R/W  
Description  
0
GPIO 0 = 1  
R/W  
Indicates that GPIO0 is being used. Set to 1 on power-up, but can be over-  
written by software. Setting this bit to 0 means AIN0 is being used.  
1
2
3
GPIO 1 = 1  
GPIO 2 = 1  
GPIO 3 = ?  
R/W  
R/W  
R/W  
Indicates that GPIO1 is being used. Set to 1 on Power-up, but can be over-  
written by software. Setting this bit to 0 means AIN1 is being used.  
Indicates that GPIO2 is being used. Set to 1 on power-up, but can be over-  
written by software.  
Indicates that GPIO3 is being used. Setting this bit to 0 means TDM1 is being  
used. The ADM1029 can detect on power-up if TDM1 is connected. If so,  
this bit is set to 0; otherwise it is set to 1. The default setting can be overwrit-  
ten by software.  
4
5
6
GPIO 4 = ?  
GPIO 5 = ?  
GPIO 6 = ?  
Reserved  
R/W  
R/W  
R/W  
R
Indicates that GPIO4 is being used. Setting this bit to 0 means TDM1 is being  
used. The ADM1029 can detect on power-up if TDM1 is connected. If so,  
this bit is set to 0; otherwise it is set to 1. The default setting can be overwrit-  
ten by software.  
Indicates that GPIO5 is being used. Setting this bit to 0 means TDM2 is being  
used. The ADM1029 can detect on power-up if TDM2 is connected. If so,  
this bit is set to 0; otherwise it is set to 1. The default setting can be overwrit-  
ten by software.  
Indicates that GPIO6 is being used. Setting this bit to 0 means TDM2 is being  
used. The ADM1029 can detect on power-up if TDM2 is connected. If so,  
this bit is set to 0; otherwise it is set to 1. The default setting can be overwrit-  
ten by software.  
7
Unused. Will read back 0.  
NOTE  
Question marks on this and following pages indicate bit settings that depend on the state of certain pins on power-up.  
Register 50h, 51h – AINx* Behavior (Power-On Default 00h)  
Bit  
Name  
R/W  
Description  
0
Assert CFAULT on  
HI_LIM = 0  
R/W  
When this bit is set, CFAULT is asserted when AINx* exceeds the AINx*  
high limit.  
1
Alarm speed on  
HI_LIM = 0  
R/W  
When this bit is set, the fans go to alarm speed when AINx* exceeds the  
AINx* high limit.  
2
3
INT on HI_LIM = 0  
R/W  
R/W  
When this bit is set, INT is asserted when AINx* exceeds the AINx* high limit.  
Alarm below low = 0  
This bit indicates whether an alarm (INT, CFAULT or Alarm Speed) is  
asserted when AINx* goes above or below the Low Limit. 1 = above. 0 = below.  
4
5
Assert CFAULT on  
LO_LIM = 0  
R/W  
R/W  
When this bit is set, CFAULT is asserted when AINx* crosses the AINx*  
low limit. Bit 3 decides whether CFAULT is asserted for going above or below  
the Low Limit.  
Alarm speed on  
LO_LIM = 0  
When this bit is set, the fans go to alarm speed when AINx* crosses the AINx*  
low limit. Bit 3 decides whether Alarm Speed is asserted for going above or  
below the Low Limit.  
6
7
INT on LO_LIM = 0  
R/W  
R/W  
When this bit is set, INT is asserted when AINx* crosses the AINx* low limit. Bit  
3 decides whether INT is asserted for going above or below the Low Limit.  
Latch AIN Fault = 0  
This bit latches an out-of-limit event (i.e., when AINx* goes above the high  
limit or crosses the low limit) on the AINx* channel. This bit is cleared by  
writing a 0 to it.  
*“x” denotes the number of the AIN channel. Register 50h controls AIN0 and 51h controls AIN1.  
Rev. 1 | Page 47 of 50 | www.onsemi.com  
ADM1029  
Register 58h, 59h – AINx* Event Mask (Power-On Default 00h)  
Bit  
Name  
R/W  
Description  
0
Fan 1 = 0  
R/W  
If an AINx* out-of-limit event is generated such that fans should be driven at  
Alarm Speed, Fan 1 will be set to this speed when this bit is set.  
1
Fan 2 = 0  
R/W  
If an AINx* out-of-limit event is generated such that fans should be driven at  
Alarm Speed, Fan 2 will be set to this speed when this bit is set.  
2
3
4
5
6
7
Reserved  
Reserved  
Reserved  
Reserved  
Reserved  
Reserved  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
Undefined  
Undefined  
Undefined  
Undefined  
Undefined  
Undefined  
*“x” denotes the number of the AIN channel. Register 58h is for AIN0 and 59h is for AIN1.  
Register A8h, A9h – AINx* High Limit (Power-On Default FFh)  
Bit  
Name  
R/W  
Description  
<7:0>  
AINx* High Limit  
R/W  
This register contains the high limit value for the AINx* analog input channel.  
*“x” denotes the number of the AIN channel. Register A8h is for AIN0 and A9h is for AIN1.  
Register B0h, B1h – AINx* Low Limit (Power-On Default 00h)  
Bit  
Name  
R/W  
Description  
<7:0>  
AINx* Low Limit  
R/W  
This register contains the low limit value for the AINx* analog input channel.  
*“x” denotes the number of the AIN channel. Register B0h is for AIN0 and B1h is for AIN1.  
Register B8h, B9h – AINx* Measured Value (Power-On Default 00h)  
Bit  
Name  
R/W  
Description  
<7:0>  
AINx* value  
R
This register contains the measured value of the AINx* analog input channel.  
*“x” denotes the number of the AIN channel. Register B8h is for AIN0 and B9h is for AIN1.  
Rev. 1 | Page 48 of 50 | www.onsemi.com  
ADM1029  
MISCELLANEOUS REGISTERS  
Register 0Bh – S/W RESET (Power-On Default 00h)  
Bit  
Name  
R/W  
Description  
<7:0>  
S/W Reset  
R/W  
Writing A6 hex to this register location causes a software reset identical to a  
power-on reset. This register is self-clearing so reading from it after the soft-  
ware reset has completed will result in 00 hex being read.  
Register 0Dh – Manufacturer’s ID (Power-On Default 41h)  
Bit  
Name  
R/W  
Description  
<7:0>  
Manufacturer’s ID Code  
R
This register contains the manufacturer’s ID code for the device.  
Register 0Eh – Revision (Power-On Default 00h)  
Bit  
Name  
R/W  
Description  
<3:0>  
<7:4>  
Minor Revision Code  
Major Revision Code  
R
R
This nibble contains the manufacturer’s code for minor revisions to the device.  
This nibble contains the manufacturer’s code for major revisions to the device  
which would likely require a S/W revision.  
Register 0Fh – Manufacturer’s Test Register (Power-On Default 00h)  
Bit  
Name  
R/W  
Description  
<7:0>  
Manufacturer’s Test  
R/W  
This register is used by the manufacturer for test purposes. It should not be  
read from or written to in normal operation.  
ORDERING GUIDE  
Model  
Temperature Range  
0°C to 100°C  
Package Description  
Package Option  
RQ-24  
ADM1029ARQZ1  
Shrink Small Outline Package (QSOP)  
Shrink Small Outline Package (QSOP)  
ADM1029ARQZ-R71  
0°C to 100°C  
RQ-24  
1Z = Pb-Free part  
Rev. 1 | Page 49 of 50 | www.onsemi.com  
ADM1029  
QSOP24 NB  
CASE 492B'01  
ISSUE A  
2X  
NOTES:  
1. DIMENSIONING AND TOLERANCING PER ASME  
Y14.5M, 1994.  
SCALE 2:1  
0.20 C  
D
D
2. CONTROLLING DIMENSION: MILLIMETERS.  
3. DIMENSION b DOES NOT INCLUDE DAMBAR  
PROTRUSION.  
D
GAUGE  
PLANE  
A
C
24  
13  
4. DIMENSION D DOES NOT INCLUDE MOLD FLASH,  
PROTRUSIONS, OR GATE BURRS. MOLD FLASH,  
PROTRUSIONS, OR GATE BURRS SHALL NOT  
EXCEED 0.15 PER SIDE. DIMENSION E1 DOES NOT  
INCLUDE INTERLEAD FLASH OR PROTRUSION.  
INTERLEAD FLASH OR PROTRUSION SHALL NOT  
EXCEED 0.15 PER SIDE. D AND E1 ARE  
DETERMINED AT DATUM H.  
L2  
E
E1  
C
L
DETAIL A  
2X  
5. DATUMS A AND B ARE DETERMINED AT DATUM H.  
2X 12 TIPS  
0.20 C  
D
MILLIMETERS  
1
12  
24X b  
DIM  
A
MIN  
1.35  
0.10  
0.20  
0.19  
MAX  
1.75  
0.25  
0.30  
0.25  
0.25 C D  
A1  
b
e
M
0.25  
C A-B D  
B
h x 45  
_
C
D
8.65 BSC  
A
H
0.10  
0.10  
C
E
6.00 BSC  
3.90 BSC  
0.635 BSC  
E1  
e
h
0.22  
0.40  
0.50  
C
L
1.27  
8
A1  
L2  
M
0.25 BSC  
SEATING  
PLANE  
24X  
M
C
0
DETAIL A  
_
_
SOLDERING FOOTPRINT  
24X  
0.42  
24X  
1.12  
24  
13  
6.40  
1
12  
0.635  
PITCH  
DIMENSIONS: MILLIMETERS  
ON Semiconductor and the ON logo are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no  
warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does SCILLC assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any  
and all liability, including without limitation special, consequential or incidental damages. “Typical” parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications and actual  
performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. SCILLC does not convey any license under its patent rights nor the rights  
of others. SCILLC products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or other applications intended to support or sustain life, or for any other application in  
which the failure of the SCILLC product could create a situation where personal injury or death may occur. Should Buyer purchase or use SCILLC products for any such unintended or unauthorized application, Buyer shall indemnify and  
hold SCILLC and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury  
or death associated with such unintended or unauthorized use, even if such claim alleges that SCILLC was negligent regarding the design or manufacture of the part. SCILLC is an Equal Opportunity/Affirmative Action Employer. This  
literature is subject to all applicable copyright laws and is not for resale in any manner.  
PUBLICATION ORDERING INFORMATION  
LITERATURE FULFILLMENT:  
N. American Technical Support: 800-282-9855 Toll Free  
USA/Canada.  
Europe, Middle East and Africa Technical Support:  
Phone: 421 33 790 2910  
Japan Customer Focus Center  
Phone: 81-3-5773-3850  
ON Semiconductor Website: www.onsemi.com  
Literature Distribution Center for ON Semiconductor  
P.O. Box 5163, Denver, Colorado 80217 USA  
Phone: 303-675-2175 or 800-344-3860 Toll Free USA/Canada  
Fax: 303-675-2176 or 800-344-3867 Toll Free USA/Canada  
Email: orderlit@onsemi.com  
Order Literature: http://www.onsemi.com/orderlit  
For additional information, please contact your local  
Sales Representative  
Rev. 1 | Page 50 of 50 | www.onsemi.com  

相关型号:

ADM1029ARQZ-REEL7

IC SPECIALTY ANALOG CIRCUIT, PDSO24, MO-137AE, QSOP-24, Analog IC:Other
ADI

ADM1030

Intelligent Temperature Monitor and PWM Fan Controller
ADI

ADM1030

Intelligent Temperature Monitor and PWM Fan Controller
ONSEMI

ADM1030ARQ

Intelligent Temperature Monitor and PWM Fan Controller
ADI

ADM1030ARQ

Intelligent Temperature Monitor and PWM Fan Controller
ONSEMI

ADM1030ARQ

DIGITAL TEMP SENSOR-SERIAL, 8BIT(s), 1Cel, RECTANGULAR, SURFACE MOUNT, MO-137AB, QSOP-16
ROCHESTER

ADM1030ARQ-REEL

Intelligent Temperature Monitor and PWM Fan Controller
ONSEMI

ADM1030ARQ-REEL

DIGITAL TEMP SENSOR-SERIAL, 8BIT(s), 1Cel, RECTANGULAR, SURFACE MOUNT, MO-137AB, QSOP-16
ROCHESTER

ADM1030ARQ-REEL7

Intelligent Temperature Monitor and PWM Fan Controller
ONSEMI

ADM1030ARQ-REEL7

DIGITAL TEMP SENSOR-SERIAL, 8BIT(s), 1Cel, RECTANGULAR, SURFACE MOUNT, MO-137AB, QSOP-16
ROCHESTER

ADM1030ARQZ

Intelligent Temperature Monitor and PWM Fan Controller
ONSEMI

ADM1030ARQZ

DIGITAL TEMP SENSOR-SERIAL, 8BIT(s), 1Cel, RECTANGULAR, SURFACE MOUNT, MO-137AB, QSOP-16
ROCHESTER