ADM1021A
Low Cost Microprocessor
System Temperature
Monitor Microcomputer
The ADM1021A is a two−channel digital thermometer and
under/overtemperature alarm, intended for use in personal computers
and other systems requiring thermal monitoring and management. The
device can measure the temperature of a microprocessor using a
diode−connected PNP transistor, which can be provided on−chip with
the Pentium® III or similar processors, or can be a low cost discrete
NPN/PNP device, such as the 2N3904/2N3906. A novel measurement
technique cancels out the absolute value of the transistor’s base emitter
voltage so that no calibration is required. The second measurement
channel measures the output of an on−chip temperature sensor to
monitor the temperature of the device and its environment.
The ADM1021A communicates over a two−wire serial interface
compatible with SMBus standards. Under/overtemperature limits can
be programmed into the device over the serial bus, and an ALERT
output signals when the on−chip or remote temperature is out of range.
This output can be used as an interrupt or as an SMBus alert.
http://onsemi.com
QSOP−16
CASE 492
MARKING DIAGRAM
1
1021AA
RQZ
#YYWW
FEATURES
xxx
#
= Device Code
= Pb−Free Package
• Alternative to the ADM1021
• On−Chip and Remote Temperature Sensing
• No Calibration Necessary
YYWW = Date Code
• 1°C Accuracy for On−Chip Sensor
• 3°C Accuracy for Remote Sensor
• Programmable Over/Undertemperature Limits
• Programmable Conversion rate
• 2−Wire SMBus Serial Interface
• Supports System Management Bus (SMBus) Alert
• 200 mA Max Operating Current
• 1 mA Standby Current
PIN ASSIGNMENT
1
NC
NC
16
15
14
13
12
11
10
9
2
3
4
5
6
7
8
V
STBY
SCLK
DD
D+
D–
NC
NC
ADM1021A
TOP VIEW
SDATA
ALERT
ADD0
NC
ADD1
GND
GND
• 3.0 V to 5.5 V Supply
• Small 16−Lead QSOP Package
APPLICATIONS
• Desktop Computers
• Notebook Computers
• Smart Batteries
ORDERING INFORMATION
See detailed ordering and shipping information in the package
dimensions section on page 14 of this data sheet.
• Industrial Controllers
• Telecom Equipment
• Instrumentation
© Semiconductor Components Industries, LLC, 2010
1
Publication Order Number:
June, 2010 − Rev. 8
ADM1021A/D
ADM1021A
ADDRESS POINTER
REGISTER
ONE-SHOT
REGISTER
CONVERSION RATE
REGISTER
ON−CHIP
TEMPERATURE
SENSOR
LOCAL TEMPERATURE
LOW LIMIT REGISTER
LOCAL TEMPERATURE
VALUE REGISTER
LOCAL TEMPERATURE
LOW LIMIT COMPARATOR
LOCAL TEMPERATURE
HIGH LIMIT REGISTER
LOCAL TEMPERATURE
HIGH LIMIT COMPARATOR
D+
D-
3
4
A−TO−D
CONVERTER
ANALOG MUX
REMOTE TEMPERATURE
LOW LIMIT COMPARATOR
REMOTE TEMPERATURE
LOW LIMIT REGISTER
BUSY
RUN/STANDBY
REMOTE TEMPERATURE
VALUE REGISTER
REMOTE TEMPERATURE
HIGH LIMIT REGISTER
REMOTE TEMPERATURE
HIGH LIMIT COMPARATOR
CONFIGURATION
REGISTER
STBY
15
11
EXTERNAL DIODE OPEN−CIRCUIT
INTERRUPT
MASKING
ALERT
STATUS REGISTER
SMBUS INTERFACE
ADM1021A
1
2
5
7
8
9
13
16
12
14
10
6
NC
V
NC
GND GND NC
NC
NC
SDATA
SCLK
ADD0
ADD1
NC = NO CONNECT
DD
Figure 1. Functional Block Diagram
ABSOLUTE MAXIMUM RATINGS
Parameter
Positive Supply Voltage (V ) to GND
Rating
Unit
−0.3 to +6.0
V
V
DD
D+, ADD0, ADD1
D− to GND
−0.3 to V +0.3
DD
−0.3 to +0.6
SCLK, SDATA, ALERT, STBY
Input Current
−0.3 to +6.0
V
50
1
mA
mA
V
Input Current, D−
ESD Rating, All Pins (Human Body Model)
2000
Continuous Power Dissipation
Up to 70°C
Derating Above 70°C
650
6.7
mW
mW/°C
Operating Temperature Range
−55 to +125
150
°C
Maximum Junction Temperature (T max)
°C
J
Storage Temperature Range
−65 to +150
300
°C
Lead Temperature, Soldering (10 sec)
IR Reflow Peak Temperature
°C
220
°C
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
NOTE: This device is ESD sensitive. Use standard ESD precautions when handling.
THERMAL CHARACTERISTICS
Parameter
Rating
16−Lead QSOP Package
q
= 105°C/W
JA
http://onsemi.com
2
ADM1021A
PIN ASSIGNMENT
Pin No.
Mnemonic
Description
1
2
NC
No Connect.
Positive Supply, 3.0 V to 5.5 V.
V
DD
3
D+
D−
Positive Connection to Remote Temperature Sensor.
Negative Connection to Remote Temperature Sensor.
No Connect.
4
5
NC
6
ADD1
GND
GND
NC
Three−State Logic Input, Higher Bit of Device Address.
Supply 0 V Connection.
7
8
Supply 0 V Connection.
9
No Connect.
10
11
12
13
14
15
16
ADD0
ALERT
SDATA
NC
Three−State Logic Input, Lower Bit of Device Address.
Open−Drain Logic Output Used as Interrupt or SMBus ALERT.
Logic Input/Output, SMBus Serial Data. Open−drain output.
No Connect.
SCLK
STBY
NC
Logic Input, SMBus Serial Clock.
Logic Input Selecting Normal Operation (High) or Standby Mode (Low).
No Connect.
ELECTRICAL CHARACTERISTICS (T = T
to T , V = 3.0 V to 3.6 V, unless otherwise noted. (Note 1)
MAX DD
A
MIN
Parameter
Test Conditions / Comments
Min
Typ
Max
Unit
Power Supply and ADC
Temperature Resolution
Guaranteed no missed codes
1.0
°C
°C
°C
Temperature Error, Local Sensor
Temperature Error, Remote Sensor
−3.0
1.0
+3.0
T = 60°C to 100°C
A
−3.0
−5.0
+3.0
+5.0
Supply Voltage Range (Note 2)
Undervoltage Lockout Threshold
Undervoltage Lockout Hysteresis
Power−On Reset Threshold
POR Threshold Hysteresis
Standby Supply Current
3.0
2.5
3.6
V
V
V
V
V
input, disables ADC, rising edge
, falling edge (Note 3)
2.7
25
2.95
DD
DD
DD
mV
V
0.9
1.7
50
2.2
5.0
mV
mA
= 3.3 V, no SMBus activity
1.0
4.0
SCLK at 10 kHz
Average Operating Supply Current
0.25 conversions/sec rate
2 conversions/sec rate
130
225
200
370
mA
mA
Auto−convert Mode, Averaged Over 4
Sec
Conversion Time
From stop bit to conversion complete
(both channels) D+ forced to D− + 0.65 V
65
115
170
ms
Remote Sensor Source Current
120
7.0
205
12
300
16
mA
High level (Note 3)
Low level (Note 3)
D− Source Voltage
0.7
50
V
Address Pin Bias Current (ADD0, ADD1)
Momentary at power−on reset
mA
http://onsemi.com
3
ADM1021A
ELECTRICAL CHARACTERISTICS (T = T
to T
, V = 3.0 V to 3.6 V, unless otherwise noted. (Note 1)
DD
A
MIN
MAX
Parameter
Test Conditions / Comments
Min
Typ
Max
Unit
SMBus Interface (See Figure 2)
Logic Input High Voltage, V
STBY, SCLK, SDATA
V
V
= 3.0 V to 5.5 V
2.2
V
V
IH
DD
Logic Input Low Voltage, V
STBY, SCLK, SDATA
= 3.0 V to 5.5 V
0.8
IL
DD
SMBus Output Low Sink Current
ALERT Output Low Sink Current
SDATA forced to 0.6 V
ALERT forced to 0.4 V
6.0
1.0
mA
mA
Logic Input Current, I , I
−1.0
+1.0
100
mA
pF
kHz
ms
IH IL
SMBus Input Capacitance, SCLK, SDATA
SMBus Clock Frequency
5.0
SMBus Clock Low Time, t
t
t
between 10% points
between 90% points
4.7
4.0
4.7
LOW
LOW
SMBus Clock High Time, t
ms
HIGH
HIGH
SMBus Start Condition Setup Time,
ms
t
SU:STA
SMBus Repeat Start Condition
Setup Time, t
250
250
4.0
4.0
250
250
0
ns
ns
ms
ms
ns
ns
ms
ms
ms
ms
Between 90% and 90% points
SU:STA
SMBus Start Condition Hold Time, t
Time from 10% of SDATA to 90% of SCLK
Time from 90% of SCLK to 10% of SDATA
Time for 10% or 90% of SDATA to 10% of SCLK
Time for 10% or 90% of SDATA to 10% of SCLK
HD:STA
SMBus Stop Condition Setup Time, t
SMBus Data Valid to SCLK
SU:STO
Rising Edge Time, t
SU:DAT
SMBus Data Hold Time, t
BUF:DAT
BUF
SMBus Bus Free Time, t
Between start/stop condition
Master clocking in data
4.7
SCLK Falling Edge to SDATA
Valid Time, t
1
1
VD:DAT
1. T
= 100°C, T
= 0°C
MAX
MIN
2. Operation at V = 5.0 V guaranteed by design; not production tested.
DD
3. Guaranteed by design; not production tested.
tHD;STA
tR
t
tF
LOW
SCL
SDA
tSU;STA
tSU;STO
t
tHIGH
tHD;DAT
tSU;DAT
HD;STA
t
BUF
S
P
P
S
Figure 2. Diagram for Serial Bus Timing
http://onsemi.com
4
ADM1021A
TYPICAL PERFORMANCE CHARACTERISTICS
20
15
10
5
5
D+ TO GND
4
250mV p−p REMOTE
0
3
2
–5
–10
–15
D+ TO V
DD
100mV p−p REMOTE
–20
–25
–30
1
0
1
10
LEAKAGE RESISTANCE (M
100
100
1k
10k
100k
1M
10M
100M
W)
FREQUENCY (Hz)
Figure 3. Temperature Error vs. PC Board Track
Resistance
Figure 4. Temperature Error vs. Power Supply
Noise Frequency
9
3
2
100mV p−p
8
7
6
UPPER SPEC LEVEL
1
5
4
DEV10
0
3
–1
50mV p−p
LOWER SPEC LEVEL
2
1
–2
–3
25mV p−p
1M
0
1
10
100
1k
10k
100k
10M
100M
60
70
90
100
50
80
110
120
FREQUENCY (Hz)
TEMPERATURE (5C)
Figure 5. Temperature Error vs. Common−Mode
Noise Frequency
Figure 6. Temperature Error vs. Pentium III
Temperature
14
12
10
8
70
60
50
40
6
V
= 3.3V
DD
30
20
4
2
0
10
0
V
= 5V
DD
–2
2
4
6
8
10
12
14
16
18
20
22
24
1
51
02
55
07
5
100 250 500 750 1000
CAPACITANCE (nF)
SCLK FREQUENCY (kHz)
Figure 7. Temperature Error vs. Capacitance
Between D+ and D−
Figure 8. Standby Supply Current vs. Clock
Frequency
http://onsemi.com
5
ADM1021A
TYPICAL PERFORMANCE CHARACTERISTICS
4
3
2
1
0
550
500
450
400
10mV p−p
350
300
250
200
150
100
3.3V
5V
50
0.0625
0.125
0.25
0.5
1
2
4
8
100k
1M
10M
FREQUENCY (Hz)
100M
1G
CONVERSION RATE (Hz)
Figure 9. Temperature Error vs. Differential−Mode
Noise Frequency
Figure 10. Operating Supply Current vs.
Conversion Rate
125
100
80
60
40
20
0
REMOTE
TEMPERATURE
100
75
50
25
0
INT
TEMPERATURE
–20
0
1
2
3
4
5
6
7
8
9
10
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
SUPPLY VOLTAGE (V)
TIME (Seconds)
Figure 11. Standby Supply Current vs. Supply
Voltage
Figure 12. Response to Thermal Shock
http://onsemi.com
6
ADM1021A
Functional Description
On initial powerup, the remote and local temperature
values default to –128°C. Since the device normally powers
up converting, a measurement of local and remote
temperature is made, and these values are then stored before
a comparison with the stored limits is made. However, if the
part is powered up in standby mode (STBY pin pulled low),
no new values are written to the register before a comparison
is made. As a result, both RLOW and LLOW are tripped in
the status register, thus generating an ALERT output. This
can be cleared in one of two ways.
The ADM1021A contains a two−channel A−to−D
converter with special input−signal conditioning to enable
operation with remote and on−chip diode temperature
sensors. When the ADM1021A is operating normally, the
A−to−D converter operates in free−running mode. The
analog input multiplexer alternately selects either the
on−chip temperature sensor to measure its local temperature
or the remote temperature sensor. These signals are digitized
by the ADC and the results stored in the local and remote
temperature value registers as 8−bit, twos complement
words.
The measurement results are compared with local and
remote, high and low temperature limits, stored in four
on−chip registers. Out−of−limit comparisons generate flags
that are stored in the status register, and one or more
out−of−limit results will cause the ALERT output to pull low.
The limit registers can be programmed and the device
controlled and configured via the serial System
Management Bus (SMBus). The contents of any register can
also be read back via the SMBus.
1. Change both the local and remote lower limits to
–128°C and read the status register (which in turn
clears the ALERT output).
2. Take the part out of standby and read the status
register (which in turn clears the ALERT output).
This works only if the measured values are within
the limit values.
Measurement Method
A simple method of measuring temperature is to exploit
the negative temperature coefficient of a diode, or the
base−emitter voltage of a transistor, operated at constant
current. Unfortunately, this technique requires calibration to
Control and configuration functions consist of:
• Switching the device between normal operation and
standby mode.
null the effect of the absolute value of V
from device to device.
which varies
BE,
• Masking or enabling the ALERT output.
• Selecting the conversion rate.
V
DD
I
I
N y 1
BIAS
V
D+
C1*
D–
OUT+
TO ADC
REMOTE
SENSING
TRANSISTOR
V
OUT–
BIAS
DIODE
LOW−PASS FILTER
= 65kHz
f
C
* CAPACITOR C1 IS OPTIONAL. IT IS ONLY NECESSARY IN NOISY ENVIRONMENTS.
C1 = 2.2nF TYP, 3nF MAX.
Figure 13. Input Signal Conditioning
The technique used in the ADM1021A is to measure the
This figure shows the external sensor as a substrate
transistor provided for temperature monitoring on some
microprocessors, but it could be a discrete transistor. If a
discrete transistor is used, the collector will not be grounded
and should be linked to the base. To prevent ground noise
interfering with the measurement, the more negative
terminal of the sensor is not referenced to ground, but is
biased above ground by an internal diode at the D– input. If
the sensor is operating in a noisy environment, one can
optionally be added as a noise filter. Its value is typically
2200 pF, but it should be no more than 3000 pF. See the
Layout Considerations section for more information.
change in V when the device is operated at two different
BE
currents. This is given by:
( )
DVBE + KTńq 1n N
(eq. 1)
where:
K is Boltzmann’s constant.
q is the charge on the electron (1.6 × 10 Coulombs).
T is the absolute temperature in Kelvins.
N is the ratio of the two currents.
–19
Figure 13 shows the input signal conditioning used to
measure the output of an external temperature sensor.
http://onsemi.com
7
ADM1021A
Temperature Data Format
To measure DV , the sensor is switched between
BE
One LSB of the ADC corresponds to 1°C so the ADC can
theoretically measure from −128°C to +127°C, although the
device does not measure temperatures below 0°C; therefore,
the actual range is 0°C to 127°C. The temperature data
format is shown in Table 1.
operating currents of I and N × I. The resulting waveform is
passed through a 65 kHz low−pass filter to remove noise,
and then to a chopper−stabilized amplifier that performs the
functions of amplification and rectification of the waveform
to produce a dc voltage proportional to DV . This voltage
BE
The results of the local and remote temperature
measurements are stored in the local and remote temperature
value registers and are compared with limits programmed
into the local and remote high and low limit registers.
is measured by the ADC to give a temperature output in
8−bit, twos complement format. To reduce the effects of
noise further, digital filtering is performed by averaging the
results of 16 measurement cycles.
Signal conditioning and measurement of the internal
temperature sensor is performed in a similar manner.
Table 1. Temperature Data Format
Temperature (5C)
Digital Output
Differences Between the ADM1021 and the ADM1021A
Although the ADM1021A is pin−for−pin compatible with
the ADM1021, there are some differences between the two
devices. Below is a summary of these differences and
reasons for the changes.
0
0 000 0000
0 000 0001
0 000 1010
0 001 1001
0 011 0010
0 100 1011
0 110 0100
0 111 1101
0 111 1111
1
10
25
50
1. The ADM1021A forces a larger current through
the remote temperature sensing diode, typically
205 mA vs. 90 mA for the ADM1021. The primary
reason for this is to improve the noise immunity of
the part.
75
100
125
127
2. As a result of the greater remote sensor source
current, the operating current of the ADM1021A is
higher than that of the ADM1021, typically
205 mA vs. 160 mA.
3. The temperature measurement range of the
ADM1021A is 0°C to 127°C, compared with
−128°C to +127°C for the ADM1021. As a result,
the ADM1021 should be used if negative
Registers
The ADM1021A contains nine registers that are used to
store the results of remote and local temperature
measurements, and high and low temperature limits, and to
configure and control the device. A description of these
registers follows, and further details are given in Table 2 to
Table 4. It should be noted that the ADM1021A’s registers
are dual port and have different addresses for read and write
operations. Attempting to write to a read address, or to read
from a write address, produces an invalid result. Register
addresses above 0x0F are reserved for future use or used for
factory test purposes and should not be written to.
temperature measurement is required.
4. The power−on reset values of the remote and local
temperature values are −128°C in the ADM1021A
as compared to 0°C in the ADM1021. As the part
is powered up converting (except when the part is
in standby mode, that is, Pin 15 is pulled low), the
part measures the actual values of remote and local
temperature and writes these to the registers.
5. The four MSBs of the revision register can be used
to identify the part. The ADM1021 revision register
reads 0x0x, and the ADM1021A reads 0x3x.
6. The power−on default value of the address pointer
register is undefined in the ADM1021A and is
equal to 0x00 in the ADM1021. As a result, a
value must be written to the address pointer
register before a read is performed in the
ADM1021A. The ADM1021 is capable of reading
back local temperature without writing to the
address pointer register, as it defaulted to the local
temperature measurement register at powerup.
7. Setting the mask bit (Bit 7 Config Reg) on the
ADM1021A masks current and future ALERTs.
On the ADM1021, the mask bit, masks only
ALERTs. Any current ALERT has to be cleared
using an ARA.
Address Pointer Register
The address pointer register does not have and does not
require an address, because it is the register to which the first
data byte of every write operation is written automatically.
This data byte is an address pointer that sets up one of the
other registers for the second byte of the write operation or
for a subsequent read operation.
Value Registers
The ADM1021A has two registers to store the results of
local and remote temperature measurements. These registers
are written to by the ADC and can only be read over the
SMBus.
Status Register
Bit 7 of the status register indicates when it is high that the
ADC is busy converting. Bit 5 to Bit 3 are flags that indicate
the results of the limit comparisons.
If the local and/or remote temperature measurement is
above the corresponding high temperature limit or below the
http://onsemi.com
8
ADM1021A
corresponding low temperature limit, then one or more of
Table 2. Status Register Bit Assignments
these flags are set. Bit 2 is a flag that is set if the remote
temperature sensor is open−circuit. These five flags are
NOR’d together so that if any of them are high, the ALERT
interrupt latch is set and the ALERT output goes low. Reading
the status register clears the five flag bits, provided the error
conditions that caused the flags to be set have gone away.
While a limit comparator is tripped due to a value register
containing an out−of−limit measurement, or the sensor is
open−circuit, the corresponding flag bit cannot be reset. A
flag bit can only be reset if the corresponding value register
contains an in−limit measurement, or the sensor is good.
Bit
Name
Function
7
BUSY
LHIGH*
LLOW*
RHIGH*
RLOW*
OPEN*
1 when ADC converting
6
1 when local high temp limit tripped
1 when local low temp limit tripped
1 when remote high temp limit tripped
1 when remote low temp limit tripped
1 when remote sensor open−circuit
Reserved
5
4
3
2
1 to 0
*These flags stay high until the status register is read or they are
reset by POR.
Table 3. List of ADM1021A Registers
Read Address (Hex)
Write Address (Hex)
Name
Power−On Default
Undefined
Not applicable
Not applicable
Address pointer
Local temperature value
Remote temperature value
Status
00
Not applicable
1000 0000 (0x80) (−128°C)
1000 0000 (0x80) (−128°C)
Undefined
01
Not applicable
02
Not applicable
03
09
Configuration
0000 0000 (0x00)
04
0A
Conversion rate
Local temperature high limit
Local temperature low limit
Remote temperature high limit
Remote temperature low limit
One−shot
0000 0010 (0x02)
05
0B
0111 1111 (0x7F) (+127°C)
1100 1001 (0xC9) (−55°C)
0111 1111 (0x7F) (+127°C)
1100 1001 (0xC9) (−55°C)
06
0C
07
0D
08
0E
Not applicable
0F (Note 1)
10
11
12
13
14
15
17
19
20
FE
FF
Not applicable
Reserved
Reserved for future versions
0000 0000 (0°C)
11
Remote temperature offset
Reserved
12
Reserved for future versions
Reserved for future versions
Reserved for future versions
Reserved for future versions
Reserved for future versions
Reserved for future versions
Reserved for future versions
0100 0001 (0x41)
13
Reserved
14
16
Reserved
Reserved
18
Reserved
Not applicable
21
Reserved
Reserved
Not applicable
Not applicable
Manufacturer device ID
Die revision code
0011 xxxx (0x3x)
1. Writing to Address 0F causes the ADM1021A to perform a single measurement. It is not a data register and data written to it is irrelevant.
The ALERT interrupt latch is not reset by reading the
status register, but is reset when the ALERT output is
serviced by the master reading the device address, provided
the error condition has gone away and the status register flag
bits have been reset.
is in standby mode and the ADC does not convert. Standby
mode can also be selected by taking the STBY pin low. In
standby mode, the values stored in the remote and local
temperature registers remain at the values they were when
the part was placed in standby.
Bit 7 of the configuration register is used to mask the
ALERT output. If Bit 7 is 0, which is the power−on default,
the ALERT output is enabled. If Bit 7 is set to 1, the ALERT
output is disabled.
Configuration Register
Two bits of the configuration register are used. If Bit 6 is 0,
which is the power−on default, the device is in operating
mode with the ADC converting. If Bit 6 is set to 1, the device
http://onsemi.com
9
ADM1021A
Table 4. Configuration Register Bit Assignments
Table 6. Offset Values
Power−On
Default
Offset Register
Remote Temperature
(Without
Bit
Name
Function
Offset
Value
(0x11)
(With Offset)
Offset)
7
MASK1
0 = ALERT Enabled
1 = ALERT Masked
0
0
0
1111 1100
1111 1111
0000 0000
0000 0001
0000 0100
−4°C
−1°C
0°C
14°C
17°C
18°C
19°C
22°C
18°C
18°C
18°C
18°C
18°C
6
RUN/STOP
0 = Run
1 = Standby
5 to 0
Reserved
+1°C
+4°C
Conversion Rate Register
The lowest three bits of this register are used to program
the conversion rate by dividing the ADC clock by 1, 2, 4, 8,
16, 32, 64, or 128 to give conversion times from 125 ms
(Code 0x07) to 16 seconds (Code 0x00). This register can be
written to and read back over the SMBus. The higher five
bits of this register are unused and must be set to 0. Use of
slower conversion times greatly reduces the device power
consumption, as shown in Table 5.
One−Shot Register
The one−shot register is used to initiate a single
conversion and comparison cycle when the ADM1021A is
in standby mode, after which the device returns to standby.
This is not a data register as such, and it is the write operation
that causes the one−shot conversion. The data written to this
address is irrelevant and is not stored.
Table 5. Conversion Rate Register Code
Serial Bus Interface
Control of the ADM1021A is carried out via the serial bus.
The ADM1021A is connected to this bus as a slave device,
under the control of a master device. Note that the SMBus
and SCL pins are three−stated when the ADM1021A is
powered down and will not pull down the SMBus.
Conversion/
Sec
Average Supply Current
Data
mA Typ at V = 3.3 V
CC
0x00
0x01
0.0625
150
150
150
150
150
150
160
180
0.125
0x02
0.25
Address Pins
0x03
0.5
In general, every SMBus device has a 7−bit device address
(except for some devices that have extended 10−bit
addresses). When the master device sends a device address
over the bus, the slave device with that address responds.
The ADM1021A has two address pins, ADD0 and ADD1,
to allow selection of the device address so that several
ADM1021A’s can be used on the same bus, and/or to avoid
conflict with other devices. Although only two address pins
are provided, these are three−state and can be grounded, left
0x04
1
0x05
2
0x06
4
8
0x07
0x08 to 0xFF
Reserved
Limit Registers
The ADM1021A has four limit registers to store local and
remote and high and low temperature limits. These registers
can be written to and read back over the SMBus. The high
limit registers perform a > comparison, while the low limit
registers perform a < comparison. For example, if the high
limit register is programmed as a limit of 80°C, measuring
81°C results in an alarm condition. Even though the
temperature measurement range is from 0° to 127°C, it is
possible to program the limit register with negative values.
This is for backwards compatibility with the ADM1021.
unconnected, or tied to V so that a total of nine different
DD
addresses are possible, as shown in Table 7.
It should be noted that the state of the address pins is only
sampled at powerup, so changing them after powerup has no
effect.
Table 7. Device Addresses (Note 1)
ADD0
ADD1
Device Address
0
0
0
NC
1
0011 000
0011 001
0011 010
0101 001
0101 010
0101 011
1001 100
1001 101
1001 110
Offset Register
An offset register is provided at Address 0x11. This allows
the user to remove errors from the measured remote
temperature. These errors can be introduced by clock noise
and PCB track resistance. See Table 6 for an example of
offset values.
The offset value is stored as an 8−bit, twos complement
value. The value of the offset is negative if the MSB of
Register 0x11 is 1, and is positive if the MSB of Register
0x11 is 0. This value is added to the remote temperature. The
offset register defaults to 0 at powerup. The offset register
range is −128°C to +127°C.
0
NC
NC
NC
1
0
NC
1
0
1
NC
1
1
1. ADD0 and ADD1 are sampled at powerup only.
http://onsemi.com
10
ADM1021A
The serial bus protocol operates as follows:
3. When all data bytes have been read or written,
stop conditions are established. In write mode, the
master pulls the data line high during the 10th
1. The master initiates data transfer by establishing a
start condition, defined as a high−to−low transition
on the serial data line SDATA, while the serial
clock line SCLK remains high. This indicates that
an address/data stream will follow. All slave
peripherals connected to the serial bus respond to
the START condition and shift in the next eight
bits, consisting of a 7−bit address (MSB first) plus
an R/W bit, which determines the direction of the
data transfer, that is, whether data will be written
to or read from the slave device.
clock pulse to assert a stop condition. In read
mode, the master device overrides the
acknowledge bit by pulling the data line high
during the low period before the ninth clock pulse.
This is known as No Acknowledge. The master
then takes the data line low during the low period
before the 10th clock pulse, then high during the
10th clock pulse to assert a stop condition.
Any number of bytes of data can be transferred over the
serial bus in one operation, but it is not possible to mix read
and write in one operation, because the type of operation is
determined at the beginning and cannot subsequently be
changed without starting a new operation.
The peripheral whose address corresponds to the
transmitted address responds by pulling the data
line low during the low period before the ninth
clock pulse, known as the Acknowledge Bit. All
other devices on the bus now remain idle while the
selected device waits for data to be read from or
written to it. If the R/W bit is a 0, the master writes
to the slave device. If the R/W bit is a 1, the
master reads from the slave device.
For the ADM1021A, write operations contain either one
or two bytes, while read operations contain one byte.
To write data to one of the device data registers or read
data from it, the address pointer register must be set so that
the correct data register is addressed, data can then be written
into that register or read from it. The first byte of a write
operation always contains a valid address that is stored in the
address pointer register. If data is to be written to the device,
the write operation contains a second data byte that is written
to the register selected by the address pointer register.
This is illustrated in Figure 14. The device address is sent
over the bus followed by R/W set to 0. This is followed by
two data bytes. The first data byte is the address of the
internal data register to be written to, which is stored in the
address pointer register. The second data byte is the data to
be written to the internal data register.
2. Data is sent over the serial bus in sequences of
nine clock pulses, eight bits of data followed by an
Acknowledge Bit from the slave device.
Transitions on the data line must occur during the
low period of the clock signal and remain stable
during the high period, because a low−to−high
transition when the clock is high can be interpreted
as a stop signal. The number of data bytes that can
be transmitted over the serial bus in a single read
or write operation is limited only by what the
master and slave devices can handle.
1
9
9
1
SCLK
D6
A6
A5
A4
A3
A2
A1
A0
D7
D5
D4
D3
D2
D1
SDATA
D0
R/W
ACK. BY
ADM1021A
START BY
MASTER
ACK. BY
ADM1021A
FRAME 2
FRAME 1
SERIAL BUS ADDRESS BYTE
ADDRESS POINTER REGISTER BYTE
1
9
SCL (CONTINUED)
SDA (CONTINUED)
D5
D4
D3
D2
D1
D7
D 6
D0
ACK. BY
ADM1021A
STOP BY
MASTER
FRAME 3
DATA BYTE
Figure 14. Writing a Register Address to the Address Pointer Register, then Writing Data to the Selected Register
http://onsemi.com
11
ADM1021A
1
9
1
9
SCLK
A1
A0
A3
A2
A6
D7
D6
D4
D2
SDATA
A5
A4
D5
D3
D1
D0
R/W
START BY
MASTER
ACK. BY
ADM1021A
ACK. BY
ADM1021A MASTER
STOP BY
FRAME 1
SERIAL BUS ADDRESS BYTE
FRAME 2
ADDRESS POINTER REGISTER BYTE
Figure 15. Writing to the Address Pointer Register Only
1
9
1
9
SCLK
A1
A0
A3
A2
A6
D7
D6
D4
D2
SDATA
A5
A4
D5
D3
D1
D0
R/W
STOP BY
MASTER
START BY
MASTER
ACK. BY
ADM1021A
NO ACK.
BY MASTER
FRAME 1
SERIAL BUS ADDRESS BYTE
FRAME 2 DATA BYTE FROM ADM1021A
Figure 16. Reading Data from a Previously Selected Register
ALERT Output
When reading data from a register there are two
possibilities:
The ALERT output goes low whenever an out−of−limit
measurement is detected, or if the remote temperature sensor
is open−circuit. It is an open drain and requires a 10 kW
1. If the ADM1021A’s address pointer register value
is unknown or not the desired value, it is first
necessary to set it to the correct value before data
can be read from the desired data register. This is
done by performing a write to the ADM1021A as
before, but only the data byte containing the
register read address is sent, because data is not to
be written to the register. This is shown in
Figure 15.
pullup to V . Several ALERT outputs can be wire−ANDed
DD
together so the common line goes low if one or more of the
ALERT outputs goes low.
The ALERT output can be used as an interrupt signal to a
processor, or it can be used as an SMBALERT. Slave devices
on the SMBus cannot normally signal to the master that they
want to talk, but the SMBALERT function allows them to do
so.
One or more ALERT outputs are connected to a common
SMBALERT line connected to the master. When the
SMBALERT line is pulled low by one of the devices, the
following procedure occurs, as shown in Figure 17.
A read operation is then performed consisting of
the serial bus address, R/W bit set to 1, followed
by the data byte read from the data register. This is
shown in Figure 16.
2. If the address pointer register is known to be
already at the desired address, data can be read
from the corresponding data register without first
writing to the address pointer register, so Figure 15
can be omitted.
MASTER
RECEIVES
SMBALERT
DEVICE NO
ADDRESS ACK
START ALERT RESPONSE ADDRESS RD ACK
STOP
MASTER SENDS
NOTES:
DEVICE SENDS
ITS ADDRESS
ARA AND READ
COMMAND
1. Although it is possible to read a data byte from a
data register without first writing to the address
pointer register, if the address pointer register is
already at the correct value, it is not possible to
write data to a register without writing to the
address pointer register; this is because the first
data byte of a write is always written to the
address pointer register.
2. Remember that the ADM1021A registers have
different addresses for read and write operations.
The write address of a register must be written to
the address pointer if data is to be written to that
register, but it is not possible to read data from that
address. The read address of a register must be
written to the address pointer before data can be
read from that register.
Figure 17. Use of SMBALERT
1. SMBALERT is pulled low.
2. Master initiates a read operation and sends the
alert response address (ARA = 0001 100). This is
a general call address that must not be used as a
specific device address.
3. The device whose ALERT output is low responds
to the alert response address and the master reads
its device address. The address of the device is
now known and it can be interrogated in the usual
way.
4. If more than one device’s ALERT output is low,
the one with the lowest device address has priority,
in accordance with normal SMBus arbitration.
http://onsemi.com
12
ADM1021A
5. Once the ADM1021A has responded to the alert
base are connected to D+ and the emitter to D−. If a PNP
transistor is used, the collector and base are connected to D−
and the emitter to D+.
The user has no choice in the case of substrate transistors,
but if a discrete transistor is used, the best accuracy is
obtained by choosing devices according to the following
criteria:
response address, it resets its ALERT output,
provided that the error condition that caused the
ALERT no longer exists. If the SMBALERT line
remains low, the master sends the ARA again, and
so on until all devices whose ALERT outputs were
low have responded.
1. Base−emitter voltage greater than 0.25 V at 6 mA,
at the highest operating temperature.
2. Base−emitter voltage less than 0.95 V at 100 mA,
at the lowest operating temperature.
Low Power Standby Modes
The ADM1021A can be put into a low power standby
mode using hardware or software, that is, by taking the
STBY input low, or by setting Bit 6 of the configuration
register. When STBY is high or Bit 6 is low, the ADM1021A
operates normally. When STBY is pulled low or Bit 6 is
high, the ADC is inhibited, so any conversion in progress is
terminated without writing the result to the corresponding
value register.
3. Base resistance less than 100 W.
4. Small variation in h (such as 50 to 150), which
FE
indicates tight control of V characteristics.
BE
Transistors, such as 2N3904, 2N3906, or equivalents, in
SOT−23 package are suitable devices to use.
The SMBus is still enabled. Power consumption in the
standby mode is reduced to less than 10 mA if there is no
SMBus activity or 100 mA if there are clock and data signals
on the bus.
These two modes are similar but not identical. When
STBY is low, conversions are completely inhibited. When
Bit 6 is set but STBY is high, a one−shot conversion of both
channels can be initiated by writing 0xXX to the one−shot
register (Address 0x0F).
Thermal Inertia and Self−Heating
Accuracy depends on the temperature of the
remote−sensing diode and/or the internal temperature sensor
being at the same temperature as that being measured, and a
number of factors can affect this. Ideally, the sensor should be
in good thermal contact with the part of the system being
measured, for example the processor. If it is not, the thermal
inertia caused by the mass of the sensor causes a lag in the
response of the sensor to a temperature change. For the
remote sensor, this should not be a problem, because it is
either a substrate transistor in the processor or a small package
device, such as SOT−23, placed in close proximity to it.
The on−chip sensor is, however, often remote from the
processor and only monitors the general ambient
temperature around the package. The thermal time constant
of the QSOP−16 package is approximately 10 seconds.
In practice, the package will have an electrical, and hence
a thermal, connection to the printed circuit board, so the
temperature rise due to self−heating is negligible.
Sensor Fault Detection
The ADM1021A has a fault detector at the D+ input that
detects if the external sensor diode is open−circuit. This is a
simple voltage comparator that trips if the voltage at D+
exceeds V – 1.0 V (typical). The output of this comparator
CC
is checked when a conversion is initiated and sets Bit 2 of the
status register if a fault is detected.
If the remote sensor voltage falls below the normal
measuring range, for example due to the diode being
short−circuited, the ADC outputs −128°C (1000 0000).
Since the normal operating temperature range of the device
only extends down to 0°C, this output code is never seen in
normal operation; therefore, it can be interpreted as a fault
condition.
In this respect, the ADM1021A differs from and improves
upon competitive devices that output 0 if the external sensor
goes short−circuit. These devices can misinterpret a genuine
0°C measurement as a fault condition.
Layout Considerations
Digital boards can be electrically noisy environments, and
because the ADM1021A is measuring very small voltages
from the remote sensor, care must be taken to minimize
noise induced at the sensor inputs. The following
precautions should be taken:
1. Place the ADM1021A as close as possible to the
remote sensing diode. Provided that the worst
noise sources, such as clock generators,
If the external diode channel is not being used and is
shorted out, the resulting ALERT can be cleared by writing
0x80 (−128°C) to the low limit register.
data/address buses, and CRTs, are avoided, this
distance can be four to eight inches.
2. Route the D+ and D− tracks close together, in
parallel, with grounded guard tracks on each side.
Provide a ground plane under the tracks, if
possible.
3. Use wide tracks to minimize inductance and
reduce noise pickup. 10 mil track minimum width
and spacing is recommended.
Factors Affecting Accuracy
Remote Sensing Diode
The ADM1021A is designed to work with substrate
transistors built into processors, or with discrete transistors.
Substrate transistors are generally PNP types with the
collector connected to the substrate. Discrete types can be
either PNP or NPN, connected as a diode (base shorted to
collector). If an NPN transistor is used, the collector and
4. Try to minimize the number of copper/solder
joints, which can cause thermocouple effects.
http://onsemi.com
13
ADM1021A
Application Circuits
Where copper/solder joints are used, ensure they
are in both the D+ and D− paths and at the same
temperature.
Thermocouple effects should not be a major
problem as 1°C corresponds to about 240 mV, and
thermocouple voltages are about 3 mV/°C of
temperature difference. Unless there are two
thermocouples with a big temperature differential
between them, thermocouple voltages should be
much less than 240 mV.
Figure 19 shows a typical application circuit for the
ADM1021A, using a discrete sensor transistor connected
via a shielded, twisted pair cable. The pullups on SCLK,
SDATA, and ALERT are required only if they are not
already provided elsewhere in the system.
The SCLK and SDATA pins of the ADM1021A can be
interfaced directly to the SMBus of an I/O chip. Figure 20
shows how the ADM1021A might be integrated into a
system using this type of I/O controller.
5. Place a 0.1 mF bypass capacitor close to the V
DD
ADM1021A
pin, and 2200 pF input filter capacitors across D+,
D− close to the ADM1021A.
V
3.3 V
ALL 10kꢁ
DD
0.1ꢀ F
STBY
6. If the distance to the remote sensor is more than
eight inches, the use of twisted pair cable is
recommended. This works up to about 6 to 12 feet.
7. For very long distances (up to 100 feet), use
shielded twisted pair, such as Belden #8451
microphone cable. Connect the twisted pair to D+
and D− and the shield to GND close to the
ADM1021A. Leave the remote end of the shield
unconnected to avoid ground loops.
D+
D–
IN
I/O
SCLK
SDATA
ALERT
TO CONTROL
CHIP
C1*
OUT
2N3904
SHIELD
ADD0
ADD1
SET TO REQUIRED
ADDRESS
* C1 IS OPTIONAL
GND
Figure 19. Typical Application Circuit
10MIL
GND
PROCESSOR
10MIL
10MIL
D–
D+
D+
ADM1021A
10MIL
SYSTEM BUS
SDATA
SCLK
ALERT
D–
10MIL
10MIL
SYSTEM
MEMORY
DISPLAY
GMCH
GND
10MIL
DISPLAY
CACHE
PCI SLOTS
Figure 18. Arrangement of Signal Tracks
HARD
CD−ROM DISK
PCI BUS
ICH
I/O CONTROLLER
HUB
Because the measurement technique uses switched
current sources, excessive cable and/or filter capacitance
can affect the measurement. When using long cables, the
filter capacitor can be reduced or removed.
Cable resistance can also introduce errors. A series
resistance of 1 W introduces about 1°C error.
2 IDE PORTS
SMBus
SUPER
I/O
USB USB
2 USB PORTS
FWH
(FIRMWARE HUB)
Figure 20. Typical System Using ADM1021A
ORDERING INFORMATION
†
Device Number
ADM1021AARQZ
Temperature Range
0°C to +100°C
Package Type
16−Lead QSOP
16−Lead QSOP
16−Lead QSOP
Package Option
RQ−16
Shipping
98 Tube
ADM1021AARQZ−R
ADM1021AARQZ−R7
0°C to +100°C
RQ−16
2500 Tape & Reel
1000 Tape & Reel
0°C to +100°C
RQ−16
†For information on tape and reel specifications, including part orientation and tape sizes, please refer to our Tape and Reel Packaging
Specifications Brochure, BRD8011/D.
*The “Z’’ suffix indicates Pb−Free part.
http://onsemi.com
14
ADM1021A
PACKAGE DIMENSIONS
QSOP16
CASE 492−01
ISSUE O
−A−
Q
NOTES:
1. DIMENSIONING AND TOLERANCING PER ANSI
Y14.5M, 1982.
R
2. CONTROLLING DIMENSION: INCH.
3. THE BOTTOM PACKAGE SHALL BE BIGGER THAN
THE TOP PACKAGE BY 4 MILS (NOTE: LEAD SIDE
ONLY). BOTTOM PACKAGE DIMENSION SHALL
FOLLOW THE DIMENSION STATED IN THIS
DRAWING.
4. PLASTIC DIMENSIONS DOES NOT INCLUDE MOLD
FLASH OR PROTRUSIONS. MOLD FLASH OR
PROTRUSIONS SHALL NOT EXCEED 6 MILS PER
SIDE.
H x 45
_
U
RAD.
0.013 X 0.005
DP. MAX
−B−
5. BOTTOM EJECTOR PIN WILL INCLUDE THE
COUNTRY OF ORIGIN (COO) AND MOLD CAVITY I.D.
MOLD PIN
MARK
INCHES
MIN
MILLIMETERS
DIM
A
B
C
D
F
MAX
0.196
0.157
0.068
0.012
0.035
MIN
4.80
3.81
1.55
0.20
0.41
MAX
4.98
3.99
1.73
0.31
0.89
0.189
0.150
0.061
0.008
0.016
RAD.
0.005−0.010
TYP
G
G
H
J
0.025 BSC
0.64 BSC
L
0.008 0.018
0.0098 0.0075
0.20
0.249
0.10
5.84
0
0.46
0.191
0.25
6.20
8
P
DETAIL E
M
0.25 (0.010)
T
K
L
0.004
0.230
0
0.010
0.244
8
M
N
P
_
_
_
_
0
0.007
7
0.011
0
0.18
7
0.28
_
_
_
_
Q
R
U
V
0.020 DIA
0.51 DIA
V
K
0.025
0.025
0
0.035
0.035
8
0.64
0.64
0
0.89
0.89
8
C
N 8 PL
_
_
_
_
−T−
D16 PL
0.25 (0.010)
SEATING
PLANE
M
S
S
A
T
B
J
M
F
DETAIL E
Protected by U.S. Patents 5,195,827; 5,867,012; 5,982,221; 6,097,239; 6,133,753; 6,169,442; other patents pending.
Pentium is a registered trademark of Intel Corporation.
ON Semiconductor and
are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC reserves the right to make changes without further notice
to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does SCILLC assume any liability
arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential or incidental damages.
“Typical” parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All
operating parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. SCILLC does not convey any license under its patent rights
nor the rights of others. SCILLC products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or other applications
intended to support or sustain life, or for any other application in which the failure of the SCILLC product could create a situation where personal injury or death may occur. Should
Buyer purchase or use SCILLC products for any such unintended or unauthorized application, Buyer shall indemnify and hold SCILLC and its officers, employees, subsidiaries, affiliates,
and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death
associated with such unintended or unauthorized use, even if such claim alleges that SCILLC was negligent regarding the design or manufacture of the part. SCILLC is an Equal
Opportunity/Affirmative Action Employer. This literature is subject to all applicable copyright laws and is not for resale in any manner.
PUBLICATION ORDERING INFORMATION
LITERATURE FULFILLMENT:
N. American Technical Support: 800−282−9855 Toll Free
USA/Canada
Europe, Middle East and Africa Technical Support:
Phone: 421 33 790 2910
Japan Customer Focus Center
Phone: 81−3−5773−3850
ON Semiconductor Website: www.onsemi.com
Order Literature: http://www.onsemi.com/orderlit
Literature Distribution Center for ON Semiconductor
P.O. Box 5163, Denver, Colorado 80217 USA
Phone: 303−675−2175 or 800−344−3860 Toll Free USA/Canada
Fax: 303−675−2176 or 800−344−3867 Toll Free USA/Canada
Email: orderlit@onsemi.com
For additional information, please contact your local
Sales Representative
ADM1021A/D
相关型号:
ADM1022ARQ-REEL7
IC 2-CHANNEL POWER SUPPLY SUPPORT CKT, PDSO16, MO-137AB, QSOP-16, Power Management Circuit
ADI
ADM1022ARQZ
IC 2-CHANNEL POWER SUPPLY SUPPORT CKT, PDSO16, MO-137AB, QSOP-16, Power Management Circuit
ADI
ADM1022ARQZ-REEL7
IC 2-CHANNEL POWER SUPPLY SUPPORT CKT, PDSO16, MO-137AB, QSOP-16, Power Management Circuit
ADI
©2020 ICPDF网 联系我们和版权申明