G3VM-61G2_10 [OMRON]
MOS FET Relays; MOS FET继电器型号: | G3VM-61G2_10 |
厂家: | OMRON ELECTRONICS LLC |
描述: | MOS FET Relays |
文件: | 总4页 (文件大小:246K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MOS FET Relays
G3VM-61G2
Ultrasensitive MOS FET Relays in 60 V Load
series for power savings, SOP Package.
• Trigger LED forward current of 1 mA (maximum)
facilitates power saving designs and prolonged battery life.
• Continuous load current of 400 mA.
• RoHS Compliant
■ Application Examples
• Broadband systems and Measurement devices
• Security systems
• Industrial equipment
Note: The actual product is marked differently from the image shown
here.
• Battery powered equipment and Amusement machines
■ List of Models
Load voltage (peak value)
Contact form
Terminals
Model
Number per stick
100
Number per tape
(See the note.)
SPST-NO
Surface-mounting
terminals
60 V
G3VM-61G2
---
2,500
G3VM-61G2(TR) ---
Note: The AC peak and DC value are given for the load voltage.
■ Dimensions
Note: All units are in millimeters unless otherwise indicated.
G3VM-61G2
0.25
4.4
0.25
3.9
2.1 max.
0.15
0.1
0.3
0.6
0.4
0.1
Note: The actual product is marked differently
0.1
Weight: 0.1 g
0.4
from the image shown here.
7.0
0.25
2.54
■ Terminal Arrangement/Internal Connections (Top View)
G3VM-61G2
4
3
4
3
Mold pin mark
OMRON logo
Pin 1 mark
Model name
LOT No.
Note: The actual product is marked differently
1
2
1
2
from the image shown here.
■ Actual Mounting Pad Dimensions (Recommended Value, Top View)
G3VM-61G2
6 to 6.3
1.2
0.8
2.54
MOS FET Relays G3VM-61G2
125
■ Absolute Maximum Ratings (Ta = 25°C)
Item
Symbol
Rating
Unit
Measurement Conditions
Input
LED forward current
IF
50
1
mA
Note:
1. The dielectric strength between the input and
output was checked by applying voltage be-
tween all pins as a group on the LED side and
all pins as a group on the light-receiving side.
Repetitive peak LED
forward current
IFP
A
100 μs pulses, 100 pps
LED forward current
reduction rate
Δ IF/°C −0.5
mA/°C Ta ≥ 25°C
LED reverse voltage
VR
Tj
5
V
Connection temperature
125
60
°C
V
Output Load voltage (AC peak/DC) VOFF
Continuous load current
(AC peak/DC)
IO
400
mA
ON current reduction rate
Connection temperature
Δ IO/°C −4.0
mA/°C Ta ≥ 25°C
°C
Tj
125
Dielectric strength between input and VI-O
output (See note 1.)
1,500
Vrms
AC for 1 min
Operating temperature
Storage temperature
Ta
−40 to +85 °C
−55 to +125 °C
With no icing or condensation
With no icing or condensation
10 s
Tstg
---
Soldering temperature (10 s)
260
°C
■ Electrical Characteristics (Ta = 25°C)
Mini-
mum
Maxi-
mum
Measurement
conditions
Item
Symbol
Typical
Unit
Input
LED forward voltage
VF
IR
1.0
1.15
---
1.3
V
IF = 10 mA
Note:
2. Turn-ON and Turn-OFF
Times
Reverse current
---
---
---
---
10
---
1
μA
pF
mA
Ω
VR = 5 V
IF
1
4
3
RL
VDD
VOUT
Capacity between terminals
Trigger LED forward current
CT
IFT
RON
30
0.4
1
V = 0, f = 1 MHz
IO = 400 mA
2
Output Maximum resistance with output ON
2
IF = 2 mA,
IO = 400 mA
IF
Current leakage when the relay is open ILEAK
---
1
1000
---
nA
pF
VOFF = 60 V
Capacity between terminals
Capacity between I/O terminals
Insulation resistance
COFF
CI-O
RI-O
---
130
0.8
---
V = 0, f = 1MHz
f = 1 MHz, Vs = 0 V
90%
VOUT
10%
tON
tOFF
---
---
pF
1,000
---
MΩ
VI-O = 500 VDC,
RoH ≤ 60%
Turn-ON time
Turn-OFF time
tON
---
---
3
1
8
3
ms
ms
IF = 2 mA, RL = 200 Ω,
V
DD = 20 V (See note 2.)
tOFF
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Symbol
VDD
IF
Minimum
---
Typical
Maximum
48
Unit
Load voltage (AC peak/DC)
Operating LED forward current
---
2
V
---
25
mA
mA
°C
Continuous load current (AC peak/DC) IO
Operating temperature Ta
---
---
---
320
65
− 20
126
MOS FET Relays G3VM-61G2
■ Engineering Data
LED forward current vs.
Continuous load current vs.
Ambient temperature
LED forward current vs.
LED forward voltage
Ambient temperature
- Ta
I
F
I
O
- Ta
IF - VF
60
50
40
30
20
10
0
500
400
300
200
100
0
100
10
1
Ta
=25ഒ
0.1
-40
-20
0
20
40
60
80
100
-40 -20
0
20
40
60
80
100
100
100
0.8
0.9
1.0
1.1
1.2
1.3
1.4
Ambient temperature Ta (ഒ)
Ambient temperature Taꢀꢁഒꢂ
LED forward voltage VF (V)
Continuous load current vs.
On-state voltage
On-state resistance vs.
Ambient temperature
Trigger LED forward current vs.
Ambient temperature
I
O
- VON
R
ON - Ta
IFT - Ta
500
1.2
1.0
0.8
0.6
0.4
0.8
0.7
400
300
200
100
0
Ta = 25 ഒ
IF = 2mA
0.6
0.5
0.4
0.3
0.2
0.1
0.0
-100
-200
-300
0.2
0.0
IO = 400mA
IF = 2mA
t < 1s
IO = 400mA
t < 1s
-400
-500
-0.4
-0.2
0
0.2
0.4
-40
-20
0
20
40
60
80
-40
-20
0
20
40
60
80
100
On-state voltage VON (V
)
Ambient temperature Ta (ഒ)
Ambient temperature Ta (ഒ)
Turn ON, Turn OFF time vs.
LED forward current
Turn ON, Turn OFF time vs.
Ambient temperature
Current leakage vs.
Ambient temperature
t
ON, tOFF - I
F
t
ON, tOFF - Ta
I LEAK - Ta
100
10
10
1
100
VDD = 20V
tON
VOFF = 60V
RL = 200 Ω
10
1
IF = 2mA
tOFF
1
0.1
tOFF
0.1
0.01
tON
VDD = 20V
RL = 200 Ω
Ta = 25 ഒ
0.1
0.001
0.01
0.1
1
10
100
-40 -20
0
20
40
60
80
100
-40 -20
0
20
40
60
80
LED forward current I
F
(mA)
Ambient temperature Ta (ഒꢂ
Ambient temperature Ta (ഒ)
MOS FET Relays G3VM-61G2
127
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.components.omron.com
OMRON ELECTRONIC
COMPONENTS LLC
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
12/10
Specifications subject to change without notice
Printed in USA
Cat. No. X302-E-1
MOS FET Relays G3VM-61G2