G3VM-61H1(TR) [OMRON]
Transistor Output SSR, 1-Channel, 1500V Isolation, ROHS COMPLIANT, SOP-6;型号: | G3VM-61H1(TR) |
厂家: | OMRON ELECTRONICS LLC |
描述: | Transistor Output SSR, 1-Channel, 1500V Isolation, ROHS COMPLIANT, SOP-6 输出元件 光电 |
文件: | 总3页 (文件大小:363K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
G3VM-61H1
MOS FET Relays
MOS FET Relays Designed for Switching
Minute Signals and Analog Signals.
• Continuous load current of 400 mA.
RoHS compliant
Note: The actual product is marked differently from the
image shown here.
■Application Examples
■ Terminal Arrangement/Internal Connections
6
5
4
• Semiconductor test equipment
• Test & Measurement equipment
• Communication equipment
• Data loggers
OMRON logo
Pin 1 mark
Model name
LOT.No.
932
1
2
3
Note: The actual product is marked differently from the image shown here.
■List of Models
Minimum package quantity
Model
Load voltage
(peak value) *
Package type Contact form
Terminals
Number per tube Number per tape and reel
G3VM-61H1
75
-
-
1a
SOP6
Surface-mounting Terminals
60 V
(SPST-NO)
G3VM-61H1 (TR)
2,500
* The AC peak and DC value are given for the load voltage.
■Absolute Maximum Ratings (Ta = 25°C)
Item
Symbol
IF
Rating
50
1
−0.5
5
125
60
400
400
800
−4.0
−4.0
−8.0
125
Unit
mA
A
Measurement conditions
Note: 1. The dielectric strength between the input and output was
checked by applying voltage between all pins as a group on
the LED side and all pins as a group on the light-receiving side.
LED forward current
Repetitive peak LED forward current
LED forward current reduction rate
LED reverse voltage
Connection temperature
Load voltage (AC peak/DC)
Connection A
IFP
100 µs pulses, 100 pps
∆IF/°C
VR
mA/°C Ta ≥ 25°C
Connection Diagram
V
°C
V
TJ
1
2
3
6
5
4
Load
AC
VOFF
Connection A
Connection B
Connection C
or
DC
Continuous
Connection B
Connection A: AC peak/DC
Connection B and C: DC
IO
mA
load current
Connection C
Connection A
1
2
3
6
5
4
Load
DC
ON current
reduction
rate
Connection B
Connection C
∆IO/°C
mA/°C Ta ≥ 25°C
°C
Connection temperature
Dielectric strength between
I/O (See note 1.)
Ambient operating temperature
Ambient storage temperature
Soldering temperature
TJ
VI-O
1500
Vrms
AC for 1 min
1
2
3
6
5
4
Load
DC
Ta
Tstg
-
−40 to +85
−55 to +125
260
°C
°C
°C
With no icing or condensation
With no icing or condensation
10 s
■Electrical Characteristics (Ta = 25°C)
Item
Symbol Minimum Typical Maximum Unit
Measurement conditions
IF = 10 mA
VR = 5 V
V = 0, f = 1 MHz
IO = 400 mA
IF = 5 mA, IO = 400 mA
IF = 5 mA, IO = 400 mA
IF = 5 mA, IO = 800 mA
VOFF = 60 V
V = 0, f = 1 MHz
f = 1 MHz, VS = 0 V
LED forward voltage
Reverse current
Capacity between terminals
Trigger LED forward current
VF
IR
1.0
-
-
-
1.15
-
30
1.6
1
1.3
10
-
3
2
V
µA
pF
mA
Ω
CT
IFT
Note: 2. Turn-ON and Turn-OFF Times
IF
1
6
RL
VDD
Connection A
Connection B
Connection C
-
Maximum
resistance
withoutputON
VOUT
2
4
RON
-
-
-
-
0.5
0.25
-
130
0.8
-
1
-
1.0
-
-
Ω
Ω
Current leakage when the relay is open
Capacity between terminals
Capacity between I/O terminals
Insulation resistance between I/O terminals
Turn-ON time
ILEAK
Coff
CI-O
RI-O
tON
µA
pF
pF
MΩ
ms
ms
IF
-
1000
-
-
-
VI-O = 500 VDC, ROH ≤ 60 %
90%
VOUT
0.8
0.1
2.0
0.5
10%
IF = 5 mA, RL = 200 Ω,
VDD = 20 V (See note 2.)
tON
tOFF
Turn-OFF time
tOFF
1
G3VM-61H1
■Recommended Operating Conditions
MOS FET Relays
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Symbol
Minimum
Typical
Maximum
Unit
V
Load voltage (AC peak/DC)
Operating LED forward current
Continuous load current (AC peak/DC)
Ambient operating temperature
VDD
IF
-
5
-
7.5
-
48
25
mA
mA
°C
IO
-
400
65
Ta
−20
-
■Engineering Data
LED forward current vs. Ambient
temperature
Continuous load current vs. Ambient LED forward current vs. LED forward
temperature
voltage
IF
- Ta
IO
- Ta
IF
- VF
100
80
60
40
20
0
1200
1000
100
Ta = 25°C
30
10
Connection C
800
600
3
1
Connection A and B
400
200
0
0.3
0.1
0.6
0.8
1
1.2
1.4
1.6
1.8
-20
0
20
40
60
80
100
120
-20
0
20
40
60
80
100
120
Ambient temperature Ta (°C)
Ambient temperature Ta (°C)
LED forward voltage V
F
(V)
Continuous load current vs. On-state On-state resistance vs. Ambient
Trigger LED forward current vs.
Ambient temperature
voltage
temperature
IO
- VON
RON - Ta
IFT - Ta
600
5
5
4
3
2
1
0
IO = 400 mA
Ta = 25°C
I
O
F
= 400 mA
= 5 mA
t < 1s
Connection A
IF = 5 mA
I
Connection A
400
4
3
2
1
0
Connection A
200
0
-200
-400
-600
-0.6
-0.4
-0.2
0
0.2
0.4
0.6
-20
0
20
40
60
80
100
-20
0
20
40
60
80
100
On-state voltage VON (V)
Ambient temperature Ta (°C)
Ambient temperature Ta (°C)
Turn ON, Turn OFF time vs. LED
forward current
Turn ON, Turn OFF time vs. Ambient
temperature
Current leakage vs. Ambient
temperature
tON, tOFF - I
F
tON, tOFF - Ta
ILEAK - Ta
5000
3000
3000
30
10
3
Ta = 25°C
VDD = 20 V
RL = 200 Ω
VOFF = 60 V
tON
1000
1000
300
500
300
tOFF
100
1
tOFF
100
30
10
0.3
0.1
VDD = 20 V
RL = 200 Ω
IF = 5 mA
50
30
tON
1
3
5
10
30 50
100
300
-20
0
20
40
60
80
100
-20
0
20
40
60
80
100
LED forward current I
F
(mA)
Ambient temperature Ta (°C)
Ambient temperature Ta (°C)
■Safety Precautions
• Refer to "Common Precautions" for all G3VM models.
2
Appearance/Dimensions
SOP6 type
■Appearance
SOP (Small Outline Packkaage)
SOP6
OMRON logo
Model name
932
Pin 1 mark
LOT.No.
Note: The actual product is marked differently from the image shown here.
■Dimensions
(Unit: mm)
Surface-mounting Terminals
Actual Mounting Pad
Dimensions
Weight: 0.13 g
0.25
4.4
(Recommended Value, TOP VIEW)
2.1 max.
0.15
0.25
6.3
6 to 6.3
1.2
0.8
0.3
0.6
0.1
0.1
0.4
0.25
2.54
2.54 2.54
0.1
0.4
7.0
Note: The actual product is marked differently from the image shown here.
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY
Contact: www.omron.com/ecb
Cat. No. K156-E1-01
0412(0412)(O)
相关型号:
G3VM-61PR1
Smallest Class in market, USOP Package MOS FET Relays with Low Output Capacitance and ON Resistance (CxR=7pF·Ω)
OMRON
G3VM-61QR
Worldâs smallest class* New S-VSON Package with Low Output Capacitance and Low ON Resistance
OMRON
©2020 ICPDF网 联系我们和版权申明