Solid State Contactor for 3-phase Motors with Built-in Soft Start/Stop and Monitor Output  
G3J-T-C  
CSM_G3J-T-C_DS_E_2_1  
New Models with AC Power Supply Input and  
Monitor Output Equivalent to Non-contact  
SPST-NO Join the G3J-T Series  
• Limiting the starting current saves energy.  
• Certified for UL and CSA.  
• Mounts with screws or to DIN Track.  
• Compact design with heat sinks (3.7-kW models: 100 × 100 ×  
130 mm (W × H × D)).  
• Built-in snubber circuit and thyristor.  
• Built-in operation indicator.  
Refer to Safety Precautions for All Solid State  
Relays.  
Appearance  
Output terminals (power supply side)  
Input terminals  
Monitor output terminals  
Starting torque adjuster (default setting: 200%)  
Ramp-up time adjuster (default setting: 1 s)  
Ramp-down time adjuster (default setting: 1 s)  
Operation indicator  
Output terminals (load side)  
Ordering Information  
List of Models  
Number of  
elements  
Isolation  
method  
Rated power  
supply voltage  
Input method  
Applicable monitor capacity  
(AC3)  
Monitor  
output  
Model  
3
Phototriac  
coupler  
100 to 240 VAC No-voltage input 3.7 kW (17.4 A) 200 to 220 VAC AC  
G3J-T217BL-C AC100-240  
G3J-T211BL-C AC100-240  
G3J-T205BL-C AC100-240  
G3J-T217BL-C DC12-24  
G3J-T211BL-C DC12-24  
G3J-T205BL-C DC12-24  
switching  
output  
(open and short-  
circuited input)  
2.2 kW (11.1 A)  
0.75 kW (4.8 A)  
3.7 kW (17.4 A)  
2.2 kW (11.1 A)  
0.75 kW (4.8 A)  
12 to 24 VDC  
DC  
switching  
output  
Accessories (Order Separately)  
Mounting Bracket  
Model  
R99-14 FOR G3J (See note.)  
Note: Use this Bracket when mounting Thermal Relay to a G3J-series SSR.  
1
G3J-T-C  
Specifications  
Certified Standards  
UL 508, CSA 22.2 No. 14  
Ratings (at an Ambient Temperature of 25°C)  
Power Supply  
Item  
Operating input power  
supply specifications  
AC Model  
DC Model  
Rated power supply voltage  
Operating voltage range  
Current consumption  
100 to 240 VAC  
85 to 264 VAC  
40 mA max. (at 100 to 240 VAC) 70 mA max. (at 12 to 24 VDC)  
12 to 24 VDC  
10.2 to 26.4 VDC  
Operating (Input) Circuit  
AC Model  
DC Model  
Input  
method voltage terminals 3 and 2  
input  
No-  
Short-circuiting/opening terminals 3 and 1 or  
Input current  
10 mA max. (at 12 to 24 VDC)  
Short-circuiting/opening terminals 3 and 1 or  
method voltage terminals 3 and 2  
Input  
No-  
SSR input short-circuited: Maximum  
impedance of 1 k,  
Maximum residual  
voltage of 1 V  
input  
SSR input turned ON: Maximum residual  
voltage of 2 V between  
short-circuited  
SSR input open:  
Relay input:  
Minimum  
impedance of  
100 kΩ  
terminals  
SSR input turned OFF:Maximum leakage  
current of 0.15 mA  
For minute signals  
Relay input:  
For minute signals  
Main Circuit (for Both AC and DC Models)  
Item  
Model  
G3J-T217BL-C  
200 to 240 VAC  
G3J-T211BL-C  
G3J-T205BL-C  
Rated load voltage  
Rated voltage range  
180 to 264 VAC  
17.4 A (at 40°C)  
0.5 A  
Rated carry current (See note 1.)  
Minimum load current  
Inrush current resistance (peak value)  
Overload resistance  
11.1 A (at 40°C)  
350 A (60 Hz, 1 cycle)  
4.8 A (at 40°C)  
500 A (60 Hz, 1 cycle)  
150 A (60 Hz, 1 cycle)  
Refer to Engineering Data on page 5  
Closed current (effective value)  
AC3  
AC4  
174 A  
111 A  
48 A  
208.8 A  
139.2 A  
174 A  
133.2 A  
57.6 A  
Breaking current (effective value) AC3  
AC4  
88.8 A  
38.4 A  
111 A  
48 A  
Applicable 3-phase inductive motor (See note 2.) 200 to 220 VAC  
200 to 220 VAC  
2.2 kW (11.1 A)  
200 to 240 VAC  
11.1 A  
200 to 220 VAC  
0.75 kW (4.8 A)  
200 to 240 VAC  
4.8 A  
load  
(AC3, AC4, AC53-a)  
3.7 kW (17.4 A)  
200 to 240 VAC  
17.4 A  
Resistive load (AC1) (See note 3.)  
Note: 1. The rated carry load depends on the ambient temperature. For details, refer to the Load Current vs. Ambient Temperature graph in  
Engineering Data.  
2. Satisfies switching test conditions of AC3, AC4, and AC53-a. (Refer to Engineering Data on page 5 for the test conditions.)  
3. Single-phase loads cannot be used.  
Monitor Output  
Note: Internal wiring  
Item  
Operating input power AC model (See note.)  
supply specifications  
DC model (See note.)  
5
5 (+)  
Rated power supply voltage  
Operating voltage range  
Rated carry current  
100 to 240 VAC  
85 to 264 VAC  
50 mA  
12 to 24 VDC  
10.2 to 26.4 VDC  
0.2 A  
6
6 ()  
AC model  
DC model  
Minimum load current  
3 mA  
3 mA  
2
G3J-T-C  
Characteristics (for Both AC and DC Models)  
Item  
Model  
G3J-T217BL-C  
G3J-T211BL-C  
G3J-T205BL-C  
Ramp-up time  
Set within a range of approx. 1 to 25 s.  
Set within a range of approx. 1 to 25 s.  
Set within a range of 200% to 450% In.  
Ramp-down time  
Starting torque (See note 1.)  
Monitor output operate time (See note 2.) After control signal input: AC model: 300 ms max. (TYP 50 ms), DC model: 50 ms max.  
Monitor output release time (See note 2.) After ramp-down time completion (after main circuit current turns OFF): 60 ms max.  
Output ON voltage drop (main circuit)  
1.6 V (RMS) max.  
Output ON voltage drop (monitor output) AC model: 3.5 VAC max., DC model: 2.0 VDC max.  
Leakage current (main circuit)  
Leakage current (monitor output)  
Insulation resistance  
Dielectric strength  
10 mA max. (at 200 VAC)  
AC model: 1.5 mA max. (at 200 VAC), DC model: 0.15 mA max. (at 24 VDC)  
100 Mmin. (at 500 VDC)  
2,500 VAC, 60 Hz for 1 min  
Vibration resistance  
10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)  
294 m/s2  
Shock resistance  
Storage temperature  
30 to 70°C (with no icing or condensation)  
20 to 60°C (with no icing or condensation)  
45 to 85 %  
Ambient operating temperature  
Ambient operating humidity  
Weight  
Approx. 890 g  
Approx. 760 g  
Approx. 760 g  
Note: 1. Provided that the starting torque is 600% In when the motor is started at full voltage.  
2. The monitor output will be ON while load current is flowing to the main circuit.  
Connections  
Connection Examples  
AC Model G3J-T@BL-C  
DC Model G3J-T@BL-C  
(NPN transistor input)  
(PNP transistor input)  
Three-phase, 200 to 220 V  
Three-phase, 200 to 220 V  
Three-phase, 200 to 220 V  
L1/R  
L2/S  
L3/T  
L1/R  
L2/S  
L3/T  
L1/R  
L2/S  
L3/T  
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
100 to  
240 VAC  
12 to  
24 VDC  
12 to  
24 VDC  
NPN Tr  
Ry  
PNP Tr  
Ry  
G3J  
G3J  
G3J  
Ry  
12 to  
24 VDC  
12 to  
24 VDC  
100 to  
240 VAC  
T1/U  
T2/V  
T3/W  
T1/U  
T2/V  
T3/W  
T1/U  
T2/V  
T3/W  
Thermal Relay  
Thermal Relay  
Thermal Relay  
M
M
M
Motor  
Motor  
Motor  
Note: Harmonized protection for motor overload is ensured by using a thermal relay. Be sure, however, to install protective devices on the power  
supply side, such as fuses and non-fuse breakers, as protection against accidents due to short-circuiting.  
3
G3J-T-C  
Example of Forward/Reverse Rotation  
Using Monitor Output  
Monitor Output Usage Example (Motor  
Stop Hold)  
G3J-T-C  
DC Model G3J-T@BL-C  
Three-phase, 200 to 220 V  
Three-phase, 200 to 220 V  
Fuse or non-fuse breaker  
Reverse  
Forward  
rotation  
rotation  
Reversible  
contactor  
L1/R  
L2/S  
L3/T  
1
2
3
4
5
6
7
8
A1  
21  
A1  
21  
22  
1
2
3
4
5
1
2
3
5
6
12 to  
24 VDC  
PLC/relay-  
sequential  
timer circuit  
NPN Tr  
Ry  
G3J  
A2  
22  
A2  
6
4
T1/U  
T2/V  
T3/W  
Thermal Relay  
M
Motor  
Brake  
(non-energized)  
L1/R  
L2/S  
L3/T  
Output from  
PLC/relay  
sequence  
1
2
3
4
5
6
7
8
Monitor Output Applications  
The monitor output will be ON while current is flowing to the main  
circuit. Use the monitor output, e.g., to switch the operation  
indicator, or to switch control signals during forward/reverse rotation  
or when a mechanical brake is used.  
G3J-T-C  
Output to  
PLC/relay  
sequence  
T1/U  
T2/V  
T3/W  
Be sure to use a surge absorber when connecting an inductive load  
to the monitor output.  
Thermal Relay  
M
Motor  
Note: Be sure to use a fuse or non-fuse breaker to protect the G3J.  
Time Chart Example  
Reversible contactor  
Forward rotation signal input  
(output form PLC)  
Reversible contactor  
Reverse rotation signal input  
(output from PLC)  
G3J-T-C  
Input signal  
(output from PLC)  
G3J-T-C  
Monitor output signal  
(input to PLC)  
Ramp-down  
time  
Ramp-down  
time  
(See note.)  
Do not use two G3J-T or G3J-C Contactors together  
for reversible operation.  
Note: Switch between forward and reverse rotation only after the  
motor rotation has come to a complete stop.  
4
G3J-T-C  
Engineering Data  
Load Current vs. Ambient Temperature  
Overload Resistance  
60 Hz, Ta of 25°C, non-repetitive (1/2 max. for repetitive application)  
(at Continuous Power)  
10,000  
20  
1,000  
G3J-T217BL-C  
Harmonized protection with thermal  
overload relays has been provided  
conforming to EN 60947-4-1 (Class  
10A/10) in this area (dotted line:  
for hot start).  
16  
100  
10  
G3J-T211BL-C  
12  
G3J-T217BL-C  
1
0.1  
8
G3J-T205BL-C  
4
0.01  
G3J-  
G3J-  
T205BL-C  
T211BL-C  
0
20  
0
100  
200  
300  
400  
0
20  
40  
60  
80  
100  
Overload current (Arms)  
Ambient temperature Ta (°C)  
Switching Frequency Conditions (AC3/AC4/AC53-a)  
AC3 Class (Immediate Start)  
AC4 Class (Inching)  
AC53-2: 6-6: 25-15,  
Actual Load Service Life Test  
6 s  
0.45 s  
0.3 s  
6Ie  
6Ie  
(Ue, cos θ = 0.35)  
(Ue, cos θ = 0.35)  
(Ue, cos θ = 0.35)  
Ie  
Ie  
6Ie  
(Ue, cos θ = 0.35)  
(Ue, cos θ = 0.35)  
1 min.  
4 min.  
0.75 s  
10 s  
10 s  
Ie: Rated carry current  
Ie: Rated carry current  
Ue: Rated load voltage (200/400 V)  
Testing for the soft-start model was performed at  
the following conditions:  
Ie: Rated carry current  
Ue: Rated load voltage (200/400 V)  
Testing for the soft-start model was performed at  
the following conditions:  
Ue: Rated load voltage (200/400 V)  
Testing for the soft-start model was performed at  
the following conditions:  
Ramp-up time = 1 s  
Starting torque = 450% In  
Ramp-up time = 1 s  
Starting torque = 450% In  
Ramp-up time = 1 s  
Starting torque = 450% In  
Testing for the soft start/stop model was  
performed at the following conditions:  
Ramp-up time = 1 s  
Testing for the soft start/stop model was  
performed at the following conditions:  
Ramp-up time = 1 s  
Testing for the soft start/stop model was  
performed at the following conditions:  
Ramp-up time = 1 s  
Ramp-down time = 1 s  
Ramp-down time = 1 s  
Ramp-down time = 1 s  
Starting torque = 450% In  
Starting torque = 450% In  
Starting torque = 450% In  
5
G3J-T-C  
Time Chart  
Power supply for  
internal drive  
Control input signal  
Monitor output operate time  
Operation indicator lit  
Monitor output  
Ramp-up time  
Ramp-down time  
Monitor output release time  
Load current  
Rated current  
Note: 1. The soft-start time and soft-stop time depend on the load characteristics (e.g., inertia and friction factor) in addition to the starting torque,  
ramp-up time, and ramp-down time. Therefore, the soft-start time or soft-stop time will not increase beyond a certain point if the ramp-up  
time and ramp-down time are increased.  
2. Due to the soft-stop control characteristics, the load current continues flowing even after the motor stops. Set to the optimum value  
according to the application.  
3. The operation indicator will light synchronized with the monitor output.  
Dimensions  
Note: All units are in millimeters unless otherwise indicated.  
15.85  
G3J-T205BL-C  
G3J-T211BL-C  
34.9  
72  
54.5  
37.1  
107.9  
Input terminals  
Three, M3 × 8  
Mounting Hole  
Dimensions  
4.6 dia.  
50 max.  
Stating torque adjuster  
Ramp-up time adjuster  
Two, 4.5-dia. or  
M4 holes  
0.2  
100 max. 90 89  
90  
Monitor  
output  
Two, M3 × 8  
Output  
terminals  
Six, M4 × 8  
0.2  
50  
Operation  
indicator  
5.5  
120 max.  
4.6 × 5.6  
Oval hole  
7.6  
13.2 13.2  
80 max.  
Ramp-down time adjuster  
6
G3J-T-C  
15.85  
G3J-T217BL-C  
44.9  
37.1  
82  
54.5  
117.8  
Monitor output  
Two, M3 × 8  
Input terminals  
Three, M3 × 8  
4.6 dia.  
Mounting Hole  
Dimensions  
50  
Stating torque adjuster  
Ramp-up time adjuster  
Two, 4.5-dia. or  
M4 holes  
0.2  
90  
100 max. 90 89  
Output  
0.2  
50  
terminals  
Six, M4 × 8  
7.6  
130 max.  
5.5  
4.6 × 5.6  
Oval hole  
Operation  
indicator  
13.2 13.2  
100 max.  
Ramp-down time adjuster  
Safety Precautions  
Refer to Safety Precautions for All Solid State Relays.  
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.  
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.  
In the interest of product improvement, specifications are subject to change without notice.  
7
Read and Understand This Catalog  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or  
comments.  
Warranty and Limitations of Liability  
WARRANTY  
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)  
from date of sale by OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR  
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS  
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER  
WARRANTIES, EXPRESS OR IMPLIED.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS  
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT  
LIABILITY.  
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS  
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT  
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.  
Application Considerations  
SUITABILITY FOR USE  
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's  
application or use of the products.  
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the  
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,  
machine, system, or other application or use.  
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible  
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:  
·
·
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.  
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,  
safety equipment, and installations subject to separate industry or government regulations.  
·
Systems, machines, and equipment that could present a risk to life or property.  
Please know and observe all prohibitions of use applicable to the products.  
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE  
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND  
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
PROGRAMMABLE PRODUCTS  
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.  
Disclaimers  
CHANGE IN SPECIFICATIONS  
Product specifications and accessories may be changed at any time based on improvements and other reasons.  
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.  
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or  
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual  
specifications of purchased products.  
DIMENSIONS AND WEIGHTS  
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.  
PERFORMANCE DATA  
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the  
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON  
Warranty and Limitations of Liability.  
ERRORS AND OMISSIONS  
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,  
typographical, or proofreading errors, or omissions.  
2008.11  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2008 All Right Reserved.  

相关型号:

G3J-T205BL

Soft-start/stop Function Starts and Stops Three-phase Motors Smoothly and Economically
OMRON

G3J-T205BL-C

Solid State Contactor for 3-phase Motors with Built-in Soft Start/Stop and Monitor Output
OMRON

G3J-T211BL

Soft-start/stop Function Starts and Stops Three-phase Motors Smoothly and Economically
OMRON

G3J-T211BL-C

Solid State Contactor for 3-phase Motors with Built-in Soft Start/Stop and Monitor Output
OMRON

G3J-T217BL

Soft-start/stop Function Starts and Stops Three-phase Motors Smoothly and Economically
OMRON

G3J-T217BL-C

Solid State Contactor for 3-phase Motors with Built-in Soft Start/Stop and Monitor Output
OMRON

G3J-T403BL

Soft-start/stop Function Starts and Stops Three-phase Motors Smoothly and Economically
OMRON

G3J-T405BL

Soft-start/stop Function Starts and Stops Three-phase Motors Smoothly and Economically
OMRON

G3J14

P-CHANNEL ENHANCEMENT MODE POWER MOSFET
GTM

G3JS403BLDC1224

Soft-start Solid State Contactors
OMRON

G3K

GLASS PASSIVATED JUNCTION RECTIFIER
VISHAY

G3K

SINTERED GLASS JUNCTION RECTIFIER VOLTAGE: 100V to 800V CURRENT: 3.0A
GULFSEMI