G3J-T205BL [OMRON]

Soft-start/stop Function Starts and Stops Three-phase Motors Smoothly and Economically;
G3J-T205BL
型号: G3J-T205BL
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Soft-start/stop Function Starts and Stops Three-phase Motors Smoothly and Economically

文件: 总4页 (文件大小:317K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Soft-start/stop Solid State Contactors  
G3J-T  
CSM_G3J-T_DS_E_3_2  
Soft-start/stop Function Starts and Stops  
Three-phase Motors Smoothly and  
Economically  
• Function like an inverter by holding down the starting current.  
• Comply with UL, CSA, IEC (400-V models only), and JEM  
requirements.  
• Mount with screws or to DIN tracks.  
• Compact monoblock construction for the G3J-T217BL  
(W: 100 × H: 100 × D: 110 mm) with a heat sink.  
• Snubber circuit and varistor are built-in.  
• Operation indicator.  
For the most recent information on models that have been certified for  
safety standards, refer to your OMRON website.  
Refer to Safety Precautions for All Solid State  
Relays.  
Model Number Structure  
Model Number Legend  
G3J-@@@@@@  
1
2 3 4 5 6 7  
1. Basic Model Name  
5. Rated Load Current  
G3J:  
Solid State Contactor  
17:  
11:  
05:  
03:  
17.4 A (200-V models)  
11.1 A (200-V models)  
4.8 A (200-V models), 5.5 A (400-V models)  
2.4 A (400-V) models  
2. Load Power Supply  
Blank:  
3. Functions  
T:  
AC output  
Soft-start/stop function  
6. Terminal Type  
4. Rated Load Power Supply Voltage  
B:  
Screw terminals  
2:  
4:  
200 VAC  
400 VAC  
7. Zero Cross Function  
L:  
Not equipped with zero cross function  
Appearance  
Output terminals (power supply)  
Operation indicator  
Input terminals  
Initial torque setting adjuster (default setting: 200%)  
Ramp-up time setting adjuster (default setting: 1 s)  
Ramp-down time setting adjuster (default setting: 1 s)  
Output terminals (load)  
1
G3J-T  
Ordering Information  
List of Models  
Number of  
elements  
Insulation method  
Rated supply  
voltage  
Input method  
Applicable motor  
Model  
3
Phototriac  
12 to 24 VDC  
No-voltage input  
(open and short-  
circuit input)  
2.2 kW (5.5 A)  
380 to 400 VAC  
200 to 220 VAC  
G3J-T405BL  
0.75 kW (2.4 A)  
3.7 kW (17.4 A)  
2.2 kW (11.1 A)  
0.75 kW (4.8 A)  
G3J-T403BL  
G3J-T217BL  
G3J-T211BL  
G3J-T205BL  
Note: When ordering, specify the rated supply voltage.  
Specifications  
Ratings (at an Ambient Temperature of 25°C)  
Power Supply  
Rated supply voltage  
Operating voltage range  
Current consumption  
12 to 24 VDC  
10.2 to 26.4 VDC  
50 mA max. (at 12 to 24 VDC)  
Operation Circuit  
Input current  
10 mA max. (at 12 to 24 VDC)  
Input method  
Short-circuiting or opening terminals 1 and COM or 2 (+) and 1  
No-voltage input (short-circuiting and  
opening inputs) (See note.)  
SSR input turned ON:A maximum residual voltage of 2 V between short-circuited terminals  
SSR input turned OFF:A maximum leakage current of 0.15 mA  
Relay input: For minute signals  
Note: Refer to Safety Precautions for the G3J-T, G3J-S, and G3J.  
Main Circuit  
Item  
Rated load voltage  
G3J-T405BL  
G3J-T403BL  
G3J-T217BL  
G3J-T211BL  
G3J-T205BL  
200 to 400 VAC (50/60 Hz)  
180 to 440 VAC (50/60 Hz)  
200 to 240 VAC (50/60 Hz)  
180 to 264 VAC (50/60 Hz)  
Load voltage range  
Rated carry current (See note 1.)  
5.5 A  
(Ta = 40°C)  
2.4 A  
(Ta = 40°C)  
17.4 A  
(Ta = 40°C)  
11.1 A  
(Ta = 40°C)  
4.8 A  
(Ta = 40°C)  
Min. load current  
0.5 A  
Peak-value current resistivity  
220 A, 60 Hz,  
1 cycle  
96 A, 60 Hz,  
1 cycle  
500 A, 60 Hz,  
1 cycle  
350 A, 60 Hz,  
1 cycle  
150 A, 60 Hz,  
1 cycle  
Overload resistance  
Refer to Information Common to the G3J, G3J-T, and G3J-S.  
Closed current  
(effective value)  
AC3  
AC4  
AC3  
AC4  
55 A  
66 A  
44 A  
55 A  
24 A  
174 A  
111 A  
48 A  
28.8 A  
19.2 A  
24 A  
208.8 A  
139.2 A  
174 A  
133.2 A  
88.8 A  
111 A  
57.6 A  
38.4 A  
48 A  
Breaking cur-  
rent  
(effective value)  
Applicable load 3-phase inductive 380 to 400 VAC, 380 to 400 VAC, 200 to 220 VAC, 200 to 220 VAC, 200 to 220 VAC,  
motor (AC3 AC4  
AC53-a)  
2.2 kW, 5.5 A  
0.75 kW, 2.4 A  
3.7 kW, 17.4 A  
2.2 kW, 11.1 A  
0.75 kW, 4.8 A  
Motors passing the AC3-class, AC4-class, and AC53-a-class switching frequency test  
(Ta = 40°C) under conditions specified by OMRON. Refer to Information Common to the G3J,  
G3J-T, and G3J-S.  
Resistive load  
200 to 400 VAC, 200 to 400 VAC, 200 to 240 VAC, 200 to 240 VAC, 200 to 240 VAC,  
(AC1) (See note 2.) 5.5 A  
2.4 A  
17.4 A  
11.1 A  
4.8 A  
Note: 1. The rated carry current varies depending on the ambient temperature. Refer to Load Current vs. Ambient Temperature under Engineering  
Data in the Information Common to the G3J-T, G3J-S, and G3J for details.  
2. No single-phase load can be connected.  
2
G3J-T  
Characteristics  
Item  
G3J-T405BL  
G3J-T403BL  
G3J-T217BL  
G3J-T211BL  
G3J-T205BL  
Ramp-up time  
Set within a range from 1 to 25 s.  
Set within a range from 1 to 25 s.  
Set within a range from 200% to 450% In.  
1.8 VRMS max.  
Ramp-down time  
Starting torque  
Output ON-voltage drop  
Leakage current  
1.6 VRMS max.  
20 mA max. (at 400 VAC)  
10 mA max. (at 200 VAC)  
Insulation resistance  
Dielectric strength  
Vibration resistance  
Shock resistance  
Ambient temperature  
100 MΩ min. (at 500 VDC)  
2,500 VAC, 50/60 Hz for 1 min  
Destruction: 10 to 55 to 10 Hz, 0.75–mm single amplitude  
Destruction: 294 m/s2  
Operating: –20°C to 60°C (with no icing or condensation)  
Storage: –30°C to 70°C (with no icing or condensation)  
Ambient humidity  
Weight  
Operating: 45% to 85%  
730 g max.  
800 g max.  
730 g max.  
Standards  
UL508 File No. E64562  
CSA22.2 No. 14 File No. LR35535  
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.  
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.  
In the interest of product improvement, specifications are subject to change without notice.  
3
Read and Understand This Catalog  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or  
comments.  
Warranty and Limitations of Liability  
WARRANTY  
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)  
from date of sale by OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR  
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS  
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER  
WARRANTIES, EXPRESS OR IMPLIED.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS  
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT  
LIABILITY.  
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS  
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT  
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.  
Application Considerations  
SUITABILITY FOR USE  
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's  
application or use of the products.  
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the  
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,  
machine, system, or other application or use.  
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible  
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:  
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.  
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,  
safety equipment, and installations subject to separate industry or government regulations.  
Systems, machines, and equipment that could present a risk to life or property.  
Please know and observe all prohibitions of use applicable to the products.  
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE  
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND  
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
PROGRAMMABLE PRODUCTS  
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.  
Disclaimers  
CHANGE IN SPECIFICATIONS  
Product specifications and accessories may be changed at any time based on improvements and other reasons.  
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.  
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or  
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual  
specifications of purchased products.  
DIMENSIONS AND WEIGHTS  
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.  
PERFORMANCE DATA  
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the  
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON  
Warranty and Limitations of Liability.  
ERRORS AND OMISSIONS  
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,  
typographical, or proofreading errors, or omissions.  
2012.8  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2012 All Right Reserved.  

相关型号:

G3J-T205BL-C

Solid State Contactor for 3-phase Motors with Built-in Soft Start/Stop and Monitor Output
OMRON

G3J-T211BL

Soft-start/stop Function Starts and Stops Three-phase Motors Smoothly and Economically
OMRON

G3J-T211BL-C

Solid State Contactor for 3-phase Motors with Built-in Soft Start/Stop and Monitor Output
OMRON

G3J-T217BL

Soft-start/stop Function Starts and Stops Three-phase Motors Smoothly and Economically
OMRON

G3J-T217BL-C

Solid State Contactor for 3-phase Motors with Built-in Soft Start/Stop and Monitor Output
OMRON

G3J-T403BL

Soft-start/stop Function Starts and Stops Three-phase Motors Smoothly and Economically
OMRON

G3J-T405BL

Soft-start/stop Function Starts and Stops Three-phase Motors Smoothly and Economically
OMRON

G3J14

P-CHANNEL ENHANCEMENT MODE POWER MOSFET
GTM

G3JS403BLDC1224

Soft-start Solid State Contactors
OMRON

G3K

GLASS PASSIVATED JUNCTION RECTIFIER
VISHAY

G3K

SINTERED GLASS JUNCTION RECTIFIER VOLTAGE: 100V to 800V CURRENT: 3.0A
GULFSEMI

G3K-2R2P-1

Analog Circuit
OMRON