E4C-LS35 [OMRON]
Through Beam Photoelectric Sensor, 10mm Min, 35mm Max, Cylindrical;![E4C-LS35](http://pdffile.icpdf.com/pdf2/p00293/img/icpdf/E4C-TS50_1774824_icpdf.jpg)
型号: | E4C-LS35 |
厂家: | ![]() |
描述: | Through Beam Photoelectric Sensor, 10mm Min, 35mm Max, Cylindrical 传感器 换能器 |
文件: | 总10页 (文件大小:181K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
![](http://public.icpdf.com/style/img/ads.jpg)
R
Ultrasonic 18 mm Cylindrical
E4C
Compact Through-Beam and
Reflective Models
H Background suppression
H NPN/PNP output, switch selectable
H Mutual interference protection for
multiple units
H DIN-rail mountable remote amplifier
Ordering Information
Description
Part number
E4C-TS50
E4C-LS35
E4C-WH4T
E4C-WH4L
Through-beam sensor
Reflective sensor
50 cm sensing distance
10 to 35 cm sensing distance
12 to 24 VDC supply voltage
Amplifier for E4C-TS50
Amplifier for E4C-LS35
J ACCESSORIES
Description
Part number
E99-C
S82K-00312
S82K-00324
Connector between two amplifiers
Switching power supply
0.25 A, 12 VDC output, 100-240 VAC input
0.13 A, 24 VDC output, 100-240 VAC input
E4C
E4C
Specifications
J RATINGS/CHARACTERISTICS
Sensors
Part number
Sensing method
Sensing distance
E4C-TS50
Through-beam
50 cm (1.64 ft)
E4C-LS35
Reflective
10 to 35 cm (3.94 to 13.78 in); possible to limit
the sensing zone within a range between 2 and
25 cm (0.79 to 9.84 in.)
Standard sensing object
Ultrasonic oscillation frequency
Directional angle (See Note 1.)
Indicator
Ambient operating temperature
Relative operating humidity
Vibration resistance
Shock resistance
10 x 10 cm flat plate
Approx. 270 kHz
±8° max.
4 x 4 cm flat plate
SENSING indicator (red LED)
-- 1 0 °C to 55°C (14°F to 131°F) with no icing
35 to 95%
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z axes
2
500 m/s (approx. 50G) 3 times each in X, Y, and Z axes
Enclosure rating
IEC IP66
2 m
Cable length
Weight
Material
Approx. 300 g (with Emitter and Receiver)
Polyacetal resin
Approx. 150 g
Nut
Case
Heat-resistant ABS resin
Note: 1. Obtainable with a signal of -6 dB.
Amplifier Units
Part number
Compatible sensor
E4C-WH4T
E3C-TS50
E4C-WH4L
E3C-LS35
Supply voltage
(operating voltage range)
12 to 24 VDC ±10% with a max. ripple ±10% (p-p)
Current consumption
100 mA max. at 12 VDC
Differential travel
Switching frequency (See Note.)
Response time
—
50 Hz
20% max. of rated sensing distance
20 Hz
10 ms ON, 10 ms OFF
25 ms ON, 25 ms OFF
Control output (residual voltage)
Operation mode
100 mA max. (NPN and PNP open collector output at 40 VDC with a residual voltage of 2 V)
Normally open or normally closed (selectable with a slide switch)
Ultrasonic speed compensation
Indicator
Yes
SENSING indicator (red LED) and STABILITY indicator (green LED)
-- 1 0 °C to 55°C (14°F to 131°F) with no icing
35 to 95%
Ambient operating temperature
Relative operating humidity
Note: The response frequencies are values obtained with the E4C used for detecting the rotating propeller-shaped disc as shown below.
Space:blade = 1:1
(This table continues on the next page.)
2
E4C
E4C
Specifications Table -- continued from previous page
Part number
E4C-WH4T
E4C-WH4L
Temperature influence
±30% max. of sensing distance at 20°C (68°F)
in the temperature range of --10°C and 55°C
(14°F to 131°F)
±10% max. of sensing distance at 20°C (68°F)
in the temperature range of --10°C and 55°C
(14°F to 131°F)
Voltage influence
±10% max. of sensing distance at a voltage between 90% and 110% of the rated power supply
voltage
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Enclosure rating
20 MΩ min. (at 500 VDC) between current carry parts and case
1,000 VAC (50/60 Hz) for 1 min between current carry parts and case
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
2
500 m/s (approx. 50G) 3 times each in X, Y, and Z directions
IEC IP40
Approvals
Weight
UL, cUL
Recognized, File No. E41515 when used with Class 2 power service
Approx. 110 g
Operation
J OUTPUT CIRCUIT
J OPERATION SELECTOR (H1/H2)
Signal received-output ON (H1)
12 to 24 V
Incident
Interrupted
ON
Load
SENSING indicator (red)
OFF
PNP output
100 mA max.
E4C
Load
Output transistor
(Both PNP and NPN outputs)
ON
main
circuit
OFF
NPN output
100 mA max.
0 V
Signal received-output OFF (H2)
J AMPLIFIER UNITS
Incident
Indicators
Interrupted
•
STABILITY Indicator (Green)
ON
SENSING indicator (red)
OFF
When this indicator is lit, the ultrasonic input into the Receiver is
sufficient, or its interruption small enough, to ensure the smooth
operation of the E4C. Do not operate the E4C when this indicator
is not lit.
Output transistor
ON
(Both PNP and NPN outputs)
OFF
•
SENSING Indicator (Red)
When this indicator is lit, the Receiver has ultrasonic input.
3
E4C
E4C
or
J ASYNCHRONOUS/SYNCHRONOUS
ly)
(See Note.)
(See Note.)
(MON/SYN) SWITCH
•
If more than one Sensor is used in one place, the Sensors
need to be in synchronous operation for the prevention of
mutual interference. A maximum of four Sensors can be in
synchronous operation.
•
•
•
Connect the DC power supply and Sensor to each Amplifier
as usual.
Use the E99-C (order separately) connector to connect the
Sensor to the Amplifier.
If the case of the connections shown in the following illustra-
tion, set the selector of only one Amplifier (No. 1 in the follow-
ing case) to MON. Set the selector of any other Amplifier to
SYN. In “MON” mode, the amplifier generates a pulse. In
“SYN” mode, the pulse is inhibited.
Sensors
Amplifiers
Note: The load in operation is connected to the output circuit of
the E4C.
Note: The E99-C Connector will be most effective if the E4C is a
reflective model although the E99-C Connector is required
by both the reflective and through-beam models. When
using through-beam models, however, be sure to maintain
enough space between adjacent Sensors to suppress
mutual interference. Refer to Sensitivity Adjuster Position
vs. Parallel Movement Characteristics in Engineering
Data.
Engineering Data
J SENSING RANGE
J PARALLEL MOVEMENT
J SENSITIVITY ADJUSTER
POSITION VS. PARALLEL
MOVEMENT
(TYPICAL)
CHARACTERISTICS
(TYPICAL)
CHARACTERISTICS
E4C-LS35
E4C-TS50
E4C-TS50+E4C-WH-4T
Obtain the point that turns Y and Y ON
Standard sensing object (4 x 4 cm flat plate)
1
2
Power supply voltage: 12 VDC
Sensitivity Adjuster: Max.
while changing the sensing distance (X).
Operating range
Sensitivity adjuster: Center
Operating range
Sensitivity adjuster: Max.
Obtain the point that turns Y and Y ON
1
2
while changing the sensing distance (X).
Sensing distance X (cm)
Setting distance X (cm)
Setting distance X (cm)
4
E4C
E4C
J OPERATING DISTANCE VS. SENSING
J OPERATING DISTANCE
VS. SENSING OBJECT
ANGLE (TYPICAL)
OBJECT SIZE (TYPICAL)
E4C-LS35
E4C-TS50
E4C-LS35
Distance adjuster:10
Zone adjuster: 25
Sensing adjuster: 10
Zone adjuster: 25
θ°
Operating range
Operating range
°
Operating range
Sensitivity adjuster: Max.
Emitter
Sensing object (dia. d mm)
Receiver
Sensing object:Column
Dia.: d (cm)
Operating distance X (cm)
Setting distance X (cm)
Object passing position X (cm)
J AMBIENT TEMPERATURE VS. VARIATION RATE OF SENSING DISTANCE (TYPICAL)
E4C-TS50+ E4C-WH4T
E4C-TS50+E4C-WH4T
E4C-TS50+E4C-WH4T
Sensor and Amplifier: Same temperature
Sensor:Constantroom temperature
Sensor: Temperature varied
variation
Amplifier: Temperature varied
Sensitivity adjuster: Max.
Amplifier: Constant room temperature
Sensitivity adjuster: Max.
Sensitivity adjuster: Max.
Ambient temperature (°C)
Ambient temperature (°C)
Ambient temperature (°C)
E4C-LS35+E4C-WH4L
E4C-LS35+E4C-WH4L
E4C-LS35+E4C-WH4L
Sensor and Amplifier: Same temperature
variation
Distance adjuster: 10
Zone adjuster: 25
Sensor: Temperature varied
Amplifier: Constant room temperature
Distance adjuster: 10
Sensor:Constantroom temperature
Amplifier: Temperature varied
Distance adjuster: 10
Zone adjuster: 25
Zone adjuster: 25
Ambient temperature (°C)
Ambient temperature (°C)
Ambient temperature (°C)
5
E4C
E4C
Dimensions
Unit: mm (inch)
J SENSORS
E4C-TS50
E4C-LS35
75 (2.95)
65
10
Mounting Holes
24
SENSITIVITY indicator
18.5 dia.
(0.73)
47
1
11 dia.
8 dia.
9 dia.
M18X1
4
(See Note.)
Note: E4C-TS50R or E4C-LS35: 3-conductor, shielded cable (6 dia., UL2791) with 7/0.25 dia. (standard length: 2 m)
E4C-TS50S: 2-conductor, shielded cable (6 dia., UL20276) with 7/0.25 dia. (standard length: 2 m)
J AMPLIFIER UNITS
E4C-WH4T and E4C-WH4L
75
mounting holes
4.5
Mounting Holes
Two, 4.5 dia.
50
75
26.5
(2.95)
62.5 66
(See N
64
(2.52)
65
73
80
(3.15)
22.5
12.5
13
12.7
Note: DIN rail mounting side
(0.05)
Nomenclature
E4C-WH4T
E4C-WH4L
Asynchronous/Syn-
chronous (MON/SYN)
operation selector
Asynchronous/Syn-
chronous (MON/SYN)
operation selector
Mode (H1/H2) selector
Mode (H1/H2) selector
Zone adjuster
SENSING indicator
STABILITY indicator
SENSING indicator
STABILITY indicator
Distance (sensing
distance) adjuster
Sensitivity adjuster
6
E4C
E4C
Installation
J CONNECTIONS
E4C-WH4T
E4C-WH4L
12 to 24 VDC
12 to 24 VDC
Output 1 (NPN)
100 mA max.,
40 VDC max.
Output 2 (PNP)
100 mA max.,
40 VDC max.
Output 2 (PNP)
100 mA max.,
40 VDC max.
Output 1 (NPN)
100 mA max.,
40 VDC max.
(Brown)
(Blue) Black
(Black)White
Red
(Brown)
(Blue) Black
Red
Shield
(Black) White
Shield
E4C-LS35
E4C-TS50
Pass the target object through the sensing range and adjust the
sensitivity so that the SENSING indicator turns ON and OFF
according the presence or absence of the object while the
STABILITY indicator is lit continuously.
J SENSITIVITY/ZONE ADJUSTMENTS
E4C-TS50 and E4C-WH4T Through-beam Models
Set the SENSITIVITY adjuster of the Receiver to maximum.
If the STABILITY indicator is not lit while the Sensor is in
operation, this may indicate a possible operational error. Check
or readjust the sensitivity.
Move the Emitter and Receiver vertically and horizontally until the
SENSING indicator of the Receiver is lit and secure the Emitter
and Receiver at the midpoint of the range within which the
STABILITY indicator is lit.
If the Emitter and Receiver are set at a distance shorter than the
rated sensing distance, reduce the sensitivity to within the range
in which the STABILITY indicator is lit. This will increase the
immunity of the Sensor against noise.
Range in which the STABILITY indicator (green) lit
Optimum lin
Range in which the SENSING indicator (red) lit
7
E4C
E4C
J E4C-LS35 AND E4C-WH4L CONVERGENT REFLECTIVE MODEL
Locate the Sensor so that both the STABILITY and SENSING indicators will be lit when the sensing object is placed at the sensing posi-
tion, and the STABILITY indicator will be lit and the SENSING indicator will turn OFF when the sensing object is removed.
Step
1
2
3
4
35 cm
Sensing
Distance adjuster
Zone adjuster
---
---
Adjustment
procedure
Place the sensing object
Move the Emitter and
Remove the sensing
The sensing zone can be
set within a range of 2 to
at the sensing position and Receiver vertically and
object and check that the
turn the distance adjuster
clockwise gradually until
both the SENSING and
STABILITY indicators are
lit. (See note 2)
horizontally and secure
the Emitter and Receiver
at the midpoint of the
SENSING indicator is OFF 25 cm with the zone
and the STABILITY
adjuster.
indicator is continuously lit.
range within which the
STABILITY indicator is lit.
Note: 1. If the STABILITY indicator is not lit while the Sensor is in operation, this indicates a possible operational error. Check or readjust
the sensitivity.
2. The sensing distance is adjustable within a range of 10 to 35 cm with the distance adjuster.
3. Adjust the sensing zone within the sensing distance adjustable range (i.e., 10 to 35 cm).
J SENSING ZONE SETTING EXAMPLE
J SENSING ZONE CHART
Example:
Sensing zone
Sensing distance set to 15 cm and zone set to 10 cm
Sensing distance Sensing zone
adjustment
adjustment
Signal
Received
Sensing distance Sensing zone
Signal Not
Received
adjustment
adjustment
Note: Make the settings as shown above to set a sensing zone
of 10 cm with a sensing distance adjustment of 15 cm.
Stable sensingzone
(adjustable)
Unstable
Non-sensing
zone
sensing zone
(Outside the ratings)
(Outside the ratings)
Note: Set the zone within a distance of 10 to 35 cm from the
Sensor. Therefore, if the distance adjuster is set to 30 cm
and zone adjuster is set to 20 cm, the sensing zone will
be 5 cm from a point 30 cm away from the Sensor.
Step
1
2
Distance
adjuster and
zone adjuster
Adjustment
procedure
Set the distance
adjuster to 15 cm
Set the zone adjuster
to 10 cm.
8
E4C
E4C
Precautions
J SENSOR MOUNTING ANGLE
If the E4C is in level control or distance control of sensing
objects, the stability of signal detection will depend on the
sensing surface condition of the objects. Considering the repose
angle of the objects, mount the E4C so that the ultrasonic beam
and the sensing surface of each object meet at right angles to
each other.
The jetting sound of air nozzles includes noise of a wide
frequency range, which will affect the operation of the E4C. Do
not use an air nozzle near the E4C.
The sensing distance of the E4C will decrease if there is any
water drops on the surface of the emitter or receiver.
The reflective model may not detect any objects if there is any
object absorbing sound, such as powder and cotton, on the
surface of the emitter or receiver.
J SURROUNDING OBJECTS
J MUTUAL INTERFERENCE
Make sure that the Sensor is free from surrounding objects that
reflect the ultrasonic beam diffusion, or the Sensor may
malfunction. In particular, pay the utmost attention so that no side
lobe of the ultrasonic beam will be reflected by such objects.
If more than one Unit is closely mounted together or used in a
narrow space, the mutual interference of the Sensors will result.
To prevent this, set the MON/SYN selector to SYN and check
that no mutual interference results.
J MOUNTING
J CONNECTIONS
Securely mount the E4C by using the nuts provided with the E4C
or the mounting holes of the E4C. Refer to Dimensions for
details.
The cord length between the Sensor and Amplifier can be a
maximum of 20 m provided that the cord is a three-conductor,
shielded cord (6 dia., UL2791) with 7/0.25 dia. If the Emitter is the
E4C-TS50S, however, use a two-conductor, non-shielded cord
(6 dia. UL20276) with 7/0.25 dia.
Do not strike the Sensor with any hammer or other object,
otherwise the E4C will no longer be water-resistant.
Do not wire the lines of the E4C along with high-tension or power
lines in the same conduit or close together, otherwise the E4C
may malfunction due to inductive noise.
If the E4C is not mounted securely, the E4C may be damaged by
vibration or may not detect sensing objects accurately due to a
possible change in the mounting position.
The power supply lines of the Amplifier can be extended up to
100 m provided that the size of the cord is 0.3 dia. or more.
J ENVIRONMENTAL CONDITIONS
Do not use the E4C at a temperature exceeding the rated range
or outdoors, otherwise the reliability and life of the E4C will
decrease.
J ADDITIONAL PRECAUTIONS
Be sure not to turn the sensitivity adjuster excessively. If the
sensitivity adjuster is turned exceeding the permissible range, no
sensitivity adjustment will be possible again.
The Ultrasonic Reflective Sensor utilizes the air as a beam
transmission media. Do not use the E4C in places with radical
convection or extreme local temperature changes. For example,
if there is a hot air curtain that causes turbulence within the
sensing area, the E4C may malfunction.
Take the measures shown in the following illustrations if multiple
reflection results.
Air curtain
Turbulence
5-dia. slit
Emitter
Wall
Wall
Urethane rubber or sponge
The sensing distance will be, however, reduced to half (i.e., 10 to
17 cm) if the slit is used.
Receiver
If the sensing zone is set to a small value (i.e., a few centimeters)
on the E4C reflective model, the E4C may require a warming-up
time of 3 minutes or more after the E4C is turned ON.
9
E4C
E4C
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
R
OMRON ON--LINE
OMRON ELECTRONICS LLC
One East Commerce Drive
Schaumburg, IL 60173
OMRON CANADA, INC.
885 Milner Avenue
Global -- http://www.omron.com
USA -- http://www.omron.com/oei
Canada -- http://www.omron.com/oci
Scarborough, Ontario M1B 5V8
1-800-55-OMRON
416-286-6465
Cat. No. CEDSAX4
11/01
Specifications subject to change without notice.
Printed in U.S.A.
相关型号: