Ultrasonic 18 mm Cylindrical  
E4C  
Compact Through-Beam and  
Reflective Models  
H Background suppression  
H NPN/PNP output, switch selectable  
H Mutual interference protection for  
multiple units  
H DIN-rail mountable remote amplifier  
Ordering Information  
Description  
Part number  
E4C-TS50  
E4C-LS35  
E4C-WH4T  
E4C-WH4L  
Through-beam sensor  
Reflective sensor  
50 cm sensing distance  
10 to 35 cm sensing distance  
12 to 24 VDC supply voltage  
Amplifier for E4C-TS50  
Amplifier for E4C-LS35  
J ACCESSORIES  
Description  
Part number  
E99-C  
S82K-00312  
S82K-00324  
Connector between two amplifiers  
Switching power supply  
0.25 A, 12 VDC output, 100-240 VAC input  
0.13 A, 24 VDC output, 100-240 VAC input  
E4C  
E4C  
Specifications  
J RATINGS/CHARACTERISTICS  
Sensors  
Part number  
Sensing method  
Sensing distance  
E4C-TS50  
Through-beam  
50 cm (1.64 ft)  
E4C-LS35  
Reflective  
10 to 35 cm (3.94 to 13.78 in); possible to limit  
the sensing zone within a range between 2 and  
25 cm (0.79 to 9.84 in.)  
Standard sensing object  
Ultrasonic oscillation frequency  
Directional angle (See Note 1.)  
Indicator  
Ambient operating temperature  
Relative operating humidity  
Vibration resistance  
Shock resistance  
10 x 10 cm flat plate  
Approx. 270 kHz  
±8° max.  
4 x 4 cm flat plate  
SENSING indicator (red LED)  
-- 1 0 °C to 55°C (14°F to 131°F) with no icing  
35 to 95%  
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z axes  
2
500 m/s (approx. 50G) 3 times each in X, Y, and Z axes  
Enclosure rating  
IEC IP66  
2 m  
Cable length  
Weight  
Material  
Approx. 300 g (with Emitter and Receiver)  
Polyacetal resin  
Approx. 150 g  
Nut  
Case  
Heat-resistant ABS resin  
Note: 1. Obtainable with a signal of -6 dB.  
Amplifier Units  
Part number  
Compatible sensor  
E4C-WH4T  
E3C-TS50  
E4C-WH4L  
E3C-LS35  
Supply voltage  
(operating voltage range)  
12 to 24 VDC ±10% with a max. ripple ±10% (p-p)  
Current consumption  
100 mA max. at 12 VDC  
Differential travel  
Switching frequency (See Note.)  
Response time  
50 Hz  
20% max. of rated sensing distance  
20 Hz  
10 ms ON, 10 ms OFF  
25 ms ON, 25 ms OFF  
Control output (residual voltage)  
Operation mode  
100 mA max. (NPN and PNP open collector output at 40 VDC with a residual voltage of 2 V)  
Normally open or normally closed (selectable with a slide switch)  
Ultrasonic speed compensation  
Indicator  
Yes  
SENSING indicator (red LED) and STABILITY indicator (green LED)  
-- 1 0 °C to 55°C (14°F to 131°F) with no icing  
35 to 95%  
Ambient operating temperature  
Relative operating humidity  
Note: The response frequencies are values obtained with the E4C used for detecting the rotating propeller-shaped disc as shown below.  
Space:blade = 1:1  
(This table continues on the next page.)  
2
E4C  
E4C  
Specifications Table -- continued from previous page  
Part number  
E4C-WH4T  
E4C-WH4L  
Temperature influence  
±30% max. of sensing distance at 20°C (68°F)  
in the temperature range of --10°C and 55°C  
(14°F to 131°F)  
±10% max. of sensing distance at 20°C (68°F)  
in the temperature range of --10°C and 55°C  
(14°F to 131°F)  
Voltage influence  
±10% max. of sensing distance at a voltage between 90% and 110% of the rated power supply  
voltage  
Insulation resistance  
Dielectric strength  
Vibration resistance  
Shock resistance  
Enclosure rating  
20 Mmin. (at 500 VDC) between current carry parts and case  
1,000 VAC (50/60 Hz) for 1 min between current carry parts and case  
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions  
2
500 m/s (approx. 50G) 3 times each in X, Y, and Z directions  
IEC IP40  
Approvals  
Weight  
UL, cUL  
Recognized, File No. E41515 when used with Class 2 power service  
Approx. 110 g  
Operation  
J OUTPUT CIRCUIT  
J OPERATION SELECTOR (H1/H2)  
Signal received-output ON (H1)  
12 to 24 V  
Incident  
Interrupted  
ON  
Load  
SENSING indicator (red)  
OFF  
PNP output  
100 mA max.  
E4C  
Load  
Output transistor  
(Both PNP and NPN outputs)  
ON  
main  
circuit  
OFF  
NPN output  
100 mA max.  
0 V  
Signal received-output OFF (H2)  
J AMPLIFIER UNITS  
Incident  
Indicators  
Interrupted  
STABILITY Indicator (Green)  
ON  
SENSING indicator (red)  
OFF  
When this indicator is lit, the ultrasonic input into the Receiver is  
sufficient, or its interruption small enough, to ensure the smooth  
operation of the E4C. Do not operate the E4C when this indicator  
is not lit.  
Output transistor  
ON  
(Both PNP and NPN outputs)  
OFF  
SENSING Indicator (Red)  
When this indicator is lit, the Receiver has ultrasonic input.  
3
E4C  
E4C  
or  
J ASYNCHRONOUS/SYNCHRONOUS  
ly)  
(See Note.)  
(See Note.)  
(MON/SYN) SWITCH  
If more than one Sensor is used in one place, the Sensors  
need to be in synchronous operation for the prevention of  
mutual interference. A maximum of four Sensors can be in  
synchronous operation.  
Connect the DC power supply and Sensor to each Amplifier  
as usual.  
Use the E99-C (order separately) connector to connect the  
Sensor to the Amplifier.  
If the case of the connections shown in the following illustra-  
tion, set the selector of only one Amplifier (No. 1 in the follow-  
ing case) to MON. Set the selector of any other Amplifier to  
SYN. In “MON” mode, the amplifier generates a pulse. In  
“SYN” mode, the pulse is inhibited.  
Sensors  
Amplifiers  
Note: The load in operation is connected to the output circuit of  
the E4C.  
Note: The E99-C Connector will be most effective if the E4C is a  
reflective model although the E99-C Connector is required  
by both the reflective and through-beam models. When  
using through-beam models, however, be sure to maintain  
enough space between adjacent Sensors to suppress  
mutual interference. Refer to Sensitivity Adjuster Position  
vs. Parallel Movement Characteristics in Engineering  
Data.  
Engineering Data  
J SENSING RANGE  
J PARALLEL MOVEMENT  
J SENSITIVITY ADJUSTER  
POSITION VS. PARALLEL  
MOVEMENT  
(TYPICAL)  
CHARACTERISTICS  
(TYPICAL)  
CHARACTERISTICS  
E4C-LS35  
E4C-TS50  
E4C-TS50+E4C-WH-4T  
Obtain the point that turns Y and Y ON  
Standard sensing object (4 x 4 cm flat plate)  
1
2
Power supply voltage: 12 VDC  
Sensitivity Adjuster: Max.  
while changing the sensing distance (X).  
Operating range  
Sensitivity adjuster: Center  
Operating range  
Sensitivity adjuster: Max.  
Obtain the point that turns Y and Y ON  
1
2
while changing the sensing distance (X).  
Sensing distance X (cm)  
Setting distance X (cm)  
Setting distance X (cm)  
4
E4C  
E4C  
J OPERATING DISTANCE VS. SENSING  
J OPERATING DISTANCE  
VS. SENSING OBJECT  
ANGLE (TYPICAL)  
OBJECT SIZE (TYPICAL)  
E4C-LS35  
E4C-TS50  
E4C-LS35  
Distance adjuster:10  
Zone adjuster: 25  
Sensing adjuster: 10  
Zone adjuster: 25  
θ°  
Operating range  
Operating range  
°
Operating range  
Sensitivity adjuster: Max.  
Emitter  
Sensing object (dia. d mm)  
Receiver  
Sensing object:Column  
Dia.: d (cm)  
Operating distance X (cm)  
Setting distance X (cm)  
Object passing position X (cm)  
J AMBIENT TEMPERATURE VS. VARIATION RATE OF SENSING DISTANCE (TYPICAL)  
E4C-TS50+ E4C-WH4T  
E4C-TS50+E4C-WH4T  
E4C-TS50+E4C-WH4T  
Sensor and Amplifier: Same temperature  
Sensor:Constantroom temperature  
Sensor: Temperature varied  
variation  
Amplifier: Temperature varied  
Sensitivity adjuster: Max.  
Amplifier: Constant room temperature  
Sensitivity adjuster: Max.  
Sensitivity adjuster: Max.  
Ambient temperature (°C)  
Ambient temperature (°C)  
Ambient temperature (°C)  
E4C-LS35+E4C-WH4L  
E4C-LS35+E4C-WH4L  
E4C-LS35+E4C-WH4L  
Sensor and Amplifier: Same temperature  
variation  
Distance adjuster: 10  
Zone adjuster: 25  
Sensor: Temperature varied  
Amplifier: Constant room temperature  
Distance adjuster: 10  
Sensor:Constantroom temperature  
Amplifier: Temperature varied  
Distance adjuster: 10  
Zone adjuster: 25  
Zone adjuster: 25  
Ambient temperature (°C)  
Ambient temperature (°C)  
Ambient temperature (°C)  
5
E4C  
E4C  
Dimensions  
Unit: mm (inch)  
J SENSORS  
E4C-TS50  
E4C-LS35  
75 (2.95)  
65  
10  
Mounting Holes  
24  
SENSITIVITY indicator  
18.5 dia.  
(0.73)  
47  
1
11 dia.  
8 dia.  
9 dia.  
M18X1  
4
(See Note.)  
Note: E4C-TS50R or E4C-LS35: 3-conductor, shielded cable (6 dia., UL2791) with 7/0.25 dia. (standard length: 2 m)  
E4C-TS50S: 2-conductor, shielded cable (6 dia., UL20276) with 7/0.25 dia. (standard length: 2 m)  
J AMPLIFIER UNITS  
E4C-WH4T and E4C-WH4L  
75  
mounting holes  
4.5  
Mounting Holes  
Two, 4.5 dia.  
50  
75  
26.5  
(2.95)  
62.5 66  
(See N
64  
(2.52)  
65  
73  
80  
(3.15)  
22.5  
12.5  
13  
12.7  
Note: DIN rail mounting side  
(0.05)  
Nomenclature  
E4C-WH4T  
E4C-WH4L  
Asynchronous/Syn-  
chronous (MON/SYN)  
operation selector  
Asynchronous/Syn-  
chronous (MON/SYN)  
operation selector  
Mode (H1/H2) selector  
Mode (H1/H2) selector  
Zone adjuster  
SENSING indicator  
STABILITY indicator  
SENSING indicator  
STABILITY indicator  
Distance (sensing  
distance) adjuster  
Sensitivity adjuster  
6
E4C  
E4C  
Installation  
J CONNECTIONS  
E4C-WH4T  
E4C-WH4L  
12 to 24 VDC  
12 to 24 VDC  
Output 1 (NPN)  
100 mA max.,  
40 VDC max.  
Output 2 (PNP)  
100 mA max.,  
40 VDC max.  
Output 2 (PNP)  
100 mA max.,  
40 VDC max.  
Output 1 (NPN)  
100 mA max.,  
40 VDC max.  
(Brown)  
(Blue) Black  
(Black)White  
Red  
(Brown)  
(Blue) Black  
Red  
Shield  
(Black) White  
Shield  
E4C-LS35  
E4C-TS50  
Pass the target object through the sensing range and adjust the  
sensitivity so that the SENSING indicator turns ON and OFF  
according the presence or absence of the object while the  
STABILITY indicator is lit continuously.  
J SENSITIVITY/ZONE ADJUSTMENTS  
E4C-TS50 and E4C-WH4T Through-beam Models  
Set the SENSITIVITY adjuster of the Receiver to maximum.  
If the STABILITY indicator is not lit while the Sensor is in  
operation, this may indicate a possible operational error. Check  
or readjust the sensitivity.  
Move the Emitter and Receiver vertically and horizontally until the  
SENSING indicator of the Receiver is lit and secure the Emitter  
and Receiver at the midpoint of the range within which the  
STABILITY indicator is lit.  
If the Emitter and Receiver are set at a distance shorter than the  
rated sensing distance, reduce the sensitivity to within the range  
in which the STABILITY indicator is lit. This will increase the  
immunity of the Sensor against noise.  
Range in which the STABILITY indicator (green) lit  
Optimum lin
Range in which the SENSING indicator (red) lit  
7
E4C  
E4C  
J E4C-LS35 AND E4C-WH4L CONVERGENT REFLECTIVE MODEL  
Locate the Sensor so that both the STABILITY and SENSING indicators will be lit when the sensing object is placed at the sensing posi-  
tion, and the STABILITY indicator will be lit and the SENSING indicator will turn OFF when the sensing object is removed.  
Step  
1
2
3
4
35 cm  
Sensing  
Distance adjuster  
Zone adjuster  
---  
---  
Adjustment  
procedure  
Place the sensing object  
Move the Emitter and  
Remove the sensing  
The sensing zone can be  
set within a range of 2 to  
at the sensing position and Receiver vertically and  
object and check that the  
turn the distance adjuster  
clockwise gradually until  
both the SENSING and  
STABILITY indicators are  
lit. (See note 2)  
horizontally and secure  
the Emitter and Receiver  
at the midpoint of the  
SENSING indicator is OFF 25 cm with the zone  
and the STABILITY  
adjuster.  
indicator is continuously lit.  
range within which the  
STABILITY indicator is lit.  
Note: 1. If the STABILITY indicator is not lit while the Sensor is in operation, this indicates a possible operational error. Check or readjust  
the sensitivity.  
2. The sensing distance is adjustable within a range of 10 to 35 cm with the distance adjuster.  
3. Adjust the sensing zone within the sensing distance adjustable range (i.e., 10 to 35 cm).  
J SENSING ZONE SETTING EXAMPLE  
J SENSING ZONE CHART  
Example:  
Sensing zone  
Sensing distance set to 15 cm and zone set to 10 cm  
Sensing distance Sensing zone  
adjustment  
adjustment  
Signal  
Received  
Sensing distance Sensing zone  
Signal Not  
Received  
adjustment  
adjustment  
Note: Make the settings as shown above to set a sensing zone  
of 10 cm with a sensing distance adjustment of 15 cm.  
Stable sensingzone  
(adjustable)  
Unstable  
Non-sensing  
zone  
sensing zone  
(Outside the ratings)  
(Outside the ratings)  
Note: Set the zone within a distance of 10 to 35 cm from the  
Sensor. Therefore, if the distance adjuster is set to 30 cm  
and zone adjuster is set to 20 cm, the sensing zone will  
be 5 cm from a point 30 cm away from the Sensor.  
Step  
1
2
Distance  
adjuster and  
zone adjuster  
Adjustment  
procedure  
Set the distance  
adjuster to 15 cm  
Set the zone adjuster  
to 10 cm.  
8
E4C  
E4C  
Precautions  
J SENSOR MOUNTING ANGLE  
If the E4C is in level control or distance control of sensing  
objects, the stability of signal detection will depend on the  
sensing surface condition of the objects. Considering the repose  
angle of the objects, mount the E4C so that the ultrasonic beam  
and the sensing surface of each object meet at right angles to  
each other.  
The jetting sound of air nozzles includes noise of a wide  
frequency range, which will affect the operation of the E4C. Do  
not use an air nozzle near the E4C.  
The sensing distance of the E4C will decrease if there is any  
water drops on the surface of the emitter or receiver.  
The reflective model may not detect any objects if there is any  
object absorbing sound, such as powder and cotton, on the  
surface of the emitter or receiver.  
J SURROUNDING OBJECTS  
J MUTUAL INTERFERENCE  
Make sure that the Sensor is free from surrounding objects that  
reflect the ultrasonic beam diffusion, or the Sensor may  
malfunction. In particular, pay the utmost attention so that no side  
lobe of the ultrasonic beam will be reflected by such objects.  
If more than one Unit is closely mounted together or used in a  
narrow space, the mutual interference of the Sensors will result.  
To prevent this, set the MON/SYN selector to SYN and check  
that no mutual interference results.  
J MOUNTING  
J CONNECTIONS  
Securely mount the E4C by using the nuts provided with the E4C  
or the mounting holes of the E4C. Refer to Dimensions for  
details.  
The cord length between the Sensor and Amplifier can be a  
maximum of 20 m provided that the cord is a three-conductor,  
shielded cord (6 dia., UL2791) with 7/0.25 dia. If the Emitter is the  
E4C-TS50S, however, use a two-conductor, non-shielded cord  
(6 dia. UL20276) with 7/0.25 dia.  
Do not strike the Sensor with any hammer or other object,  
otherwise the E4C will no longer be water-resistant.  
Do not wire the lines of the E4C along with high-tension or power  
lines in the same conduit or close together, otherwise the E4C  
may malfunction due to inductive noise.  
If the E4C is not mounted securely, the E4C may be damaged by  
vibration or may not detect sensing objects accurately due to a  
possible change in the mounting position.  
The power supply lines of the Amplifier can be extended up to  
100 m provided that the size of the cord is 0.3 dia. or more.  
J ENVIRONMENTAL CONDITIONS  
Do not use the E4C at a temperature exceeding the rated range  
or outdoors, otherwise the reliability and life of the E4C will  
decrease.  
J ADDITIONAL PRECAUTIONS  
Be sure not to turn the sensitivity adjuster excessively. If the  
sensitivity adjuster is turned exceeding the permissible range, no  
sensitivity adjustment will be possible again.  
The Ultrasonic Reflective Sensor utilizes the air as a beam  
transmission media. Do not use the E4C in places with radical  
convection or extreme local temperature changes. For example,  
if there is a hot air curtain that causes turbulence within the  
sensing area, the E4C may malfunction.  
Take the measures shown in the following illustrations if multiple  
reflection results.  
Air curtain  
Turbulence  
5-dia. slit  
Emitter  
Wall  
Wall  
Urethane rubber or sponge  
The sensing distance will be, however, reduced to half (i.e., 10 to  
17 cm) if the slit is used.  
Receiver  
If the sensing zone is set to a small value (i.e., a few centimeters)  
on the E4C reflective model, the E4C may require a warming-up  
time of 3 minutes or more after the E4C is turned ON.  
9
E4C  
E4C  
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.  
R
OMRON ON--LINE  
OMRON ELECTRONICS LLC  
One East Commerce Drive  
Schaumburg, IL 60173  
OMRON CANADA, INC.  
885 Milner Avenue  
Global -- http://www.omron.com  
USA -- http://www.omron.com/oei  
Canada -- http://www.omron.com/oci  
Scarborough, Ontario M1B 5V8  
1-800-55-OMRON  
416-286-6465  
Cat. No. CEDSAX4  
11/01  
Specifications subject to change without notice.  
Printed in U.S.A.  

相关型号:

E4C0117N

2 13/16 DIAMETER 11.0 AMPS 28 VDC
ETC

E4C0117S

2 13/16 DIAMETER 11.0 AMPS 28 VDC
ETC

E4C0208N

2 13/16 DIAMETER 11.0 AMPS 28 VDC
ETC

E4C0208S

2 13/16 DIAMETER 11.0 AMPS 28 VDC
ETC

E4C0217N

2 13/16 DIAMETER 11.0 AMPS 28 VDC
ETC

E4C0217S

2 13/16 DIAMETER 11.0 AMPS 28 VDC
ETC

E4C0305N

2 13/16 DIAMETER 11.0 AMPS 28 VDC
ETC

E4C0305S

2 13/16 DIAMETER 11.0 AMPS 28 VDC
ETC

E4C0317N

2 13/16 DIAMETER 11.0 AMPS 28 VDC
ETC

E4C0317S

2 13/16 DIAMETER 11.0 AMPS 28 VDC
ETC

E4C0408N

2 13/16 DIAMETER 11.0 AMPS 28 VDC
ETC

E4C0408S

2 13/16 DIAMETER 11.0 AMPS 28 VDC
ETC