E32-T84S [OMRON]
Optical Fiber Photoelectric Sensor; 光纤光电传感器型号: | E32-T84S |
厂家: | OMRON ELECTRONICS LLC |
描述: | Optical Fiber Photoelectric Sensor |
文件: | 总64页 (文件大小:1102K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Sensing distance
Supply voltage
Output
12 to 24 VDC
100 mA
(Optical fiber series)
Optical Fiber Photoelectric Sensor
E3X
Leading-edge Features and
Long-distance Sensing in an Optical
Fiber Photoelectric Sensor
E3X-Tjj with Auto-tuning Function
Automatic Sensitivity Adjustment
E3X-H11 High-sensitivity Model
Senses Distances Twice as Far as those of
E3X-Ajj and Performs Detailed Sensing
Operations Using the Variable Hysteresis
Function
E3X-Ajj Standard Model
A High-speed Response of 200 µs
E3X-Fjj High-speed Model
Pulse Lighting Mechanism Enables a
High-speed Response of 20 µs
E3X-VGjj Mark Sensor Model
Green Light Source Accurately Senses Subtle
Differences in Color at a Speed of 200 ms
Ordering Information
Model Number Legend:
E3X -
1
2 3 4
1. Classification
3. Outputs
1: NPN (without self-diagnosis)
T: Auto-tuning
H: High-sensitivity
2: NPN (with self-diagnosis)
4: PNP (without self-diagnosis)
5: PNP (with self-diagnosis)
A: General-purpose
F: Shorter response time
V: For mark sensor
4. Output Form
2. Light Source
1: Cable
None: Red (standard)
G:
Green
Accessories (Order Separately)
(Cannot be used with the E3X-Tjj.)
1
E3X
E3X
Item
Manual Sensitivity Adjustment Knob
Protective Cover
Replacement part for cover supplied with
Application
Makes adjustment possible without
screwdriver. Water-resistance lost when used Amplifier Unit.
(enclosure rating reduced to IP50).
Model
E39-G3
E39-G4
Appearance
Amplifier Units
Item
Auto-tuning
E3X-T21
High-sensitivity
E3X-H11
Model
E3X-T11
Appearance
32
12
59
Light source
Red LED (660 nm)
Power supply voltage
12 to 24 VDC
+
10%, ripple (p-p) 10% max.
10 to 30 VDC +10%, ripple
(p-p) 10% max.
Current consumption
Response time
50 mA max.
35 mA max.
500 ms max.
1 m sec max.
Control output
100 mA max. at 30 VDC, NPN open collector
T
imer function
---
---
OFF-delay timer (fixed to 40 ms), switch selectable
Self-diagnosis alarm output
50 mA max. at 30 VDC, open ---
collector
Variable hysteresis function
---
0% to 20%
T
uning monitor function
Indicator (red/green LED) and buzzer
---
---
Remote tuning function/
Remote bank function
---
When ON, short-circuit the
blue and pink wires.
(Short-circuit the blue and
purple wires for remote bank
selection.):
Short-circuit voltage 3 V
max., short-circuit current
5 mA min.
When OFF, open the blue
and pink wires: 9 V min.
(input voltage: 24 V max.),
response time 100 ms max.
when OFF
.
Output method
Light ON and Dark ON selector
2
E3X
E3X
Item
General-purpose
Shorter response
time
For mark sensing
Model
NPN
PNP
E3X-A11
E3X-A21
E3X-A51
E3X-F21
E3X-F51
E3X-VG11
---
E3X-VG21
---
E3X-A41
Appearance
Light source
Red (660 nm)
Green (565 nm)
Power supply voltage
10 to 30 VDC ripple (p-p)
10% max.
12 to 24 VDC +10% 10 to 30 VDC ripple (p-p) 10% max.
ripple (p-p)
10% max.
Current consumption
Response time
35 mA max.
40 mA max.
200 ms max.
ON: 20 ms max.
OFF: 30 ms max.
200 ms max.
Control output
100 mA, 30 VDC max., Open collector
T
imer function
---
---
---
OFF-delay timer (0.01 to 0.1 s;
adjustable), Switch selectable
---
OFF-delay timer
(0.01 to 0.1 s;
adjustable),
Switch selectable
Self-diagnosis alarm output
50 mA, 30 VDC max.
Residual voltage: 1 VDC max.
---
---
50 mA, 30 VDC
max.
Residual voltage: 1
VDC max.
External
diagnosis input
Input voltage
Light OFF:
NPN: 1.5 V max; short current: 0.2 mA
Light OFF: 1.5 V
max;
max.
short current: 0.2 mA
max.
Light ON: Open;
3.5 V min. (max.
input: 5 V)
PNP: ±1.5 V max.; short current:
0.2 mA max.
Light ON:
NPN: Open; Light OFF: 3.5 V min.
(max. input: 5 V)
PNP: Open; ±3.5 VDC max.
(max. input: 5 V)
Response delay
400 ms
200 ms
400 ms
3
E3X
E3X
Fiber Unit
Through-beam (Separate) Sensors
Model
Appearance
Sensing distance (standard object)*
(T: E3X-Tjj H: E3X-H11; A: E3X-Ajj;
F: E3X-Fjj; V: E3X-VGjj)
Min. sensing object
(opaque objects)
Features
;
E32-T11L
T: 500 mm (1,200 mm**) (1.4-mm dia. min.) T: 0.2-mm dia.
H: 700 mm (2,000 mm**) (1.4-mm dia. min.) H: 0.5-mm dia.
A: 350 mm (1,000 mm**) (1.4-mm dia. min.) A: 0.5-mm dia.
Long distance
Long distance
M4 screw
F: 150 mm (1.4-mm dia. min.)
V: 40 mm (120 mm**) (1.4-mm dia. min.)
F: 0.5-mm dia.
V: 0.5-mm dia.
E32-T12L
E32-T21L
E32-T22L
E32-TC200
T: 500 mm (1.4-mm dia. min.)
H: 700 mm (1.4-mm dia. min.)
A: 350 mm (1.4-mm dia. min.)
F: 150 mm (1.4-mm dia. min.)
V: 40 mm (1.4-mm dia. min.)
T: 0.2-mm dia.
H: 0.5-mm dia.
A: 0.5-mm dia.
F: 0.5-mm dia.
V: 0.5-mm dia.
3-mm dia.
M3 screw
T: 150 mm (0.9-mm dia. min.)
H: 200 mm (0.9-mm dia. min.)
A: 100 mm (0.9-mm dia. min.)
F: 50 mm (0.9-mm dia. min.)
V: 10 mm (0.9-mm dia. min.)
0.2-mm dia.
0.2-mm dia.
0.2-mm dia.
0.2-mm dia.
0.2-mm dia.
0.2-mm dia.
0.2-mm dia.
Long distance with
thin fiber
T: 150 mm (0.9-mm dia. min.)
H: 200 mm (0.9-mm dia. min.)
A: 100 mm (0.9-mm dia. min.)
F: 50 mm (0.9-mm dia. min.)
V: 10 mm (0.9-mm dia. min.)
Long distance with
thin fiber
2-mm dia.
M4 screw
T: 270 mm (2,000 mm**) (1-mm dia. min.)
H: 400 mm (3,000 mm**) (1-mm dia. min.)
A: 200 mm (1,500 mm**) (1-mm dia. min.)
F: 80 mm (1-mm dia. min.)
General-purpose
General-purpose
General-purpose
General-purpose
General-purpose
General-purpose
V: 28 mm (190 mm**) (1-mm dia. min.)
E32-TC200B
E32-TC200B4
T: 270 mm (1-mm dia. min.)
H: 400 mm (1-mm dia. min.)
A: 180 mm (1-mm dia. min.)
F: 80 mm (1-mm dia. min.)
V: 28 mm (1-mm dia. min.)
M4 screw
E32-T22
T: 70 mm (0.5-mm dia. min.)
H: 100 mm (0.5-mm dia. min.)
A: 50 mm (0.5-mm dia. min.)
F: 26 mm (0.5-mm dia. min.)
V: 7 mm (0.5-mm dia. min.)
2-mm dia.
M3 screw
E32-TC200E
T: 70 mm (0.5-mm dia. min.)
H: 100 mm (0.5-mm dia. min.)
A: 50 mm (0.5-mm dia. min.)
F: 26 mm (0.5-mm dia. min.)
V: 8 mm (0.5-mm dia. min.)
E32-TC200F
E32-TC200F4
T: 70 mm (0.5-mm dia. min.)
H: 100 mm (0.5-mm dia. min.)
A: 50 mm (0.5-mm dia. min.)
F: 26 mm (0.5-mm dia. min.)
V: 8 mm (0.5-mm dia. min.)
M3 screw
E32-TC200A
E32-T11
T: 250 mm (1-mm dia. min.)
H: 360 mm (1-mm dia. min.)
A: 180 mm (1-mm dia. min.)
F: 80 mm (1-mm dia. min.)
V: 28 mm (1-mm dia. min.)
T: 0.2-mm dia.
H: 0.3-mm dia.
A: 0.2-mm dia.
F: 0.2-mm dia.
V: 0.2-mm dia.
M3 screw
M4 screw
T: 240 mm (1,300 mm**) (1-mm dia. min.)
H: 360 mm (1-mm dia. min.)
A: 180 mm (1,000 mm**) (1-mm dia. min.)
F: 80 mm (1-mm dia. min.)
V: 10 mm (120 mm**) (1-mm dia. min.)
T: 0.2-mm dia.
H: 0.3-mm dia.
A: 0.2-mm dia.
F: 0.2-mm dia.
V: 0.2-mm dia.
Flexible (resists
breaking)
E32-T21
T: 65 mm (0.5-mm dia. min.)
H: 100 mm (0.5-mm dia. min.)
A: 50 mm (0.5-mm dia. min.)
F: 26 mm (0.5-mm dia. min.)
V: 6 mm (0.5-mm dia. min.)
0.2-mm dia.
Flexible (resists
breaking)
M3 screw
*Standard object: opaque; **For the E39-F1; ***Not trimmable
4
E3X
E3X
Model
Appearance
Sensing distance (standard object)*
(T: E3X-Tjj H: E3X-H11; A: E3X-Ajj;
Min. sensing object
(opaque objects)
Features
;
F: E3X-Fjj; V: E3X-VGjj)
E32-TC200C
T: 200 mm (800 mm**) (1-mm dia. min.)
H: 300 mm (1,600 mm**) (1-mm dia. min.)
A: 150 mm (800 mm**) (1-mm dia. min.)
F: 60 mm (1-mm dia. min.)
0.2-mm dia.
Flexible spiral cord
Flexible spiral cord
M4 screw
****
V: 18 mm (100 mm) (1-mm dia. min.)
E32-TC200D
E32-TC200D4
T: 200 mm (1-mm dia. min.)
H: 300 mm (1-mm dia. min.)
A: 150 mm (1-mm dia. min.)
F: 60 mm (1-mm dia. min.)
V: 18 mm (1-mm dia. min.)
0.2-mm dia.
M4 screw
3-mm dia.
****
E32-T14L
E32-T24
E32-T14
E32-T17L
E32-T12F
E32-M21
E32-T51
E32-T61
T: 130 mm (1-mm dia. min.)
H: 240 mm (1-mm dia. min.)
A: 120 mm (1-mm dia. min.)
F: 30 mm (1-mm dia. min.)
V: 10 mm (1-mm dia. min.)
T: 0.3-mm dia.
H: 0.2-mm dia.
A: 0.1-mm dia.
F: 0.2-mm dia.
V: 0.1-mm dia.
Side-view;
long distance
T: 45 mm (0.5-mm dia. min.)
H: 90 mm (0.5-mm dia. min.)
A: 45 mm (0.5-mm dia. min.)
F: 15 mm (0.5-mm dia. min.)
V: 2 mm (0.5-mm dia. min.)
T: 0.2-mm dia.
H: 0.1-mm dia.
A: 0.1-mm dia.
F: 0.3-mm dia.
V: 0.2-mm dia.
Side-view;
save space
1-mm dia.
T: 1,000 mm (4-mm dia. min.)
H: 1,800 mm (4-mm dia. min.)
A: 900 mm (4-mm dia. min.)
F: 380 mm (4-mm dia. min.)
V: 80 mm (4-mm dia. min.)
T: 0.2-mm dia.
H: 1-mm dia.
A: 1-mm dia.
F: 0.2-mm dia.
V: 2-mm dia.
Side-view
T: 7,000 mm (10-mm dia. min.)
H: 14,000 mm (10-mm dia. min.)
A: 7,000 mm (10-mm dia. min.)
F: 3,000 mm (10-mm dia. min.)
V: 800 mm (10-mm dia. min.)
T: 0.7-mm dia.
H: 2.1-mm dia.
A: 0.8-mm dia.
F: 1.5-mm dia.
V: 2.1-mm dia.
Long distance
M4 screw
T: 1,000 mm (4-mm dia. min.)
H: 1,600 mm (4-mm dia. min.)
A: 800 mm (4-mm dia. min.)
F: 300 mm (4-mm dia. min.)
V: 70 mm (4-mm dia. min.)
T: 0.3-mm dia.
H: 0.7-mm dia.
A: 0.9-mm dia.
F: 0.7-mm dia.
V: 0.6-mm dia.
Teflon-covered*****;
withstands
chemicals and harsh
environments
5-mm dia.
T: 200 mm (2-mm dia. min.)
H: 300 mm (2-mm dia. min.)
A: 150 mm (2-mm dia. min.)
F: 65 mm (2-mm dia. min.)
V: 20 mm (2-mm dia. min.)
T: 0.2-mm dia.
H: 0.4-mm dia.
A: 0.3-mm dia.
F: 0.3-mm dia.
V: 0.3-mm dia.
4-head;
4-point sensing
M3 screw
****
T: 300 mm (1.5-mm dia. min.)
H: 400 mm (1.5-mm dia. min.)
A: 200 mm (1.5-mm dia. min.)
F: 80 mm (1.5-mm dia. min.)
V: 20 mm (1.5-mm dia. min.)
T: 0.4-mm dia.
H: 1.0-mm dia.
A: 1.0-mm dia.
F: 1.0-mm dia.
V: 1.0-mm dia.
Heat-resistant;
resists 150°C
M4 screw
T: 180 mm (2,000 mm**) (1.0-mm dia. min.) T: 0.2-mm dia.
H: 300 mm (3,000 mm**) (1.0-mm dia. min.) H: 0.3-mm dia.
A: 150 mm (1,500 mm**) (1.0-mm dia. min.) A: 0.2-mm dia.
Heat-resistant;
resists 300°C
M4 screw
****
F: 60 mm (450 mm) (1.0-mm dia. min.)
V: 18 mm (130 mm**) (1.0-mm dia. min.)
F: 0.5-mm dia.
V: 0.5-mm dia.
*Standard object: opaque; **For the E39-F1.; ***Sensing distances for slit applications are in the following table.
****Not trimmable
*****Teflon is a registered trademark of the Dupont Company and the Mitsui Dupont Chemical Company for their fluoride resin.
5
E3X
E3X
E32-T16 with Slits
Slit width
0.5-mm
1.0-mm
Sensing method
With
Sensing distance
450 mm
800 mm
Sensing object
E3X-Tjj
With
Min. sensing object
Sensing distance
Min. sensing object
Sensing distance
Min. sensing object
Sensing distance
Min. sensing object
Sensing distance
0.2-mm dia.
900 mm
0.3-mm dia.
1,200 mm
0.4-mm dia.
600 mm
E3X-H11
With
0.2-mm dia.
450 mm
Slit
E3X-Ajj
With
0.25-mm dia.
120 mm
0.35-mm dia.
250 mm
E3X-Fjj
With
0.25-mm dia.
20 mm
0.35-mm dia.
60 mm
E3X-VGjj Min. sensing object
0.25-mm dia.
0.35-mm dia.
Reflective Sensors
Model
Appearance
Sensing distance (standard object)
(T: E3X-Tjj H: E3X-H11; A: E3X-Ajj;
F: E3X-Fjj; V: E3X-VGjj)
Min. sensing object
Features
;
(copper wire)
White paper Black paper
E32-D11L
T: 150 mm (20 x 20 cm) T: 40 mm (20 x 20 cm)
H: 200 mm (20 x 20 cm) H: 60 mm (20 x 20 cm)
A: 100 mm (10 x 10 cm) A: 30 mm (10 x 10 cm)
T: 0.015-mm dia.
H: 0.015-mm dia.
A: 0.015-mm dia.
F: 0.2-mm dia.
V: 3.0-mm dia.
Long distance
M6 screw
F: 45 mm (5 x 5 cm)
F: 8 mm (5 x 5 cm)
V: 10 mm (2.5 x 2.5 cm) V: ---
E32-D12
T: 80 mm (10 x 10 cm)
H: 120 mm (20 x 20 cm) H: 32 mm (20 x 20 cm)
A: 60 mm (10 x 10 cm)
F: 15 mm (2.5 x 2.5 cm) F: 3 mm (2.5 x 2.5 cm)
T: 20 mm (10 x 10 cm)
T: 0.015-mm dia.
H: 0.015-mm dia.
A: 0.04-mm dia.
F: 2.4-mm dia.
V: 1.6-mm dia.
Long distance
3 mm dia.
A: 16 mm (10 x 10 cm)
V: 2 mm (2.5 x 2.5 cm)
V: ---
E32-D21L
E32-D22L
E32-DC200
T: 35 mm (5 x 5 cm)
H: 50 mm (5 x 5 cm)
A: 25 mm (2.5 x 2.5 cm) A: 7 mm (2.5 x 2.5 cm)
F: 11 mm (2.5 x 2.5 cm) F: 2 mm (2.5 x 2.5 cm)
V: 1 mm (2.5 x 2.5 cm)
T: 9 mm (5 x 5 cm)
H: 14 mm (5 x 5 cm)
T: 0.015-mm dia.
H: 0.015-mm dia.
A: 0.03-mm dia.
F: 0.26-mm dia.
V: 1.0-mm dia.
Long distance
M4 screw
V: ---
T: 35 mm (5 x 5 cm)
H: 50 mm (5 x 5 cm)
A: 25 mm (2.5 x 2.5 cm) A: 7 mm (2.5 x 2.5 cm)
F: 11 mm (2.5 x 2.5 cm) F: 2 mm (2.5 x 2.5 cm)
V: 1 mm (2.5 x 2.5 cm)
T: 9 mm (5 x 5 cm)
H: 14 mm (5 x 5 cm)
T: 0.015-mm dia.
H: 0.015-mm dia.
A: 0.03-mm dia.
F: 0.26-mm dia.
V: 1.0-mm dia.
Long distance
3 mm dia.
V: ---
T: 100 mm (10 x 10 cm) T: 20 mm (10 x 10 cm)
H: 150 mm (20 x 20 cm) H: 30 mm (20 x 20 cm)
A: 75 mm (10 x 10 cm)
F: 33 mm (5 x 5 cm)
V: 10 mm (2.5 x 2.5 cm) V: ---
T: 0.015-mm dia.
H: 0.015-mm dia.
A: 0.015-mm dia.
F: 0.015-mm dia.
V: 0.2-mm dia.
General-purpose
General-purpose
General-purpose
General-purpose
M6 screw
M6 screw
M3 screw
A: 15 mm (10 x 10 cm)
F: 5 mm (5 x 5 cm)
E32-DC200B
E32-DC200B4
T: 100 mm (10 x 10 cm) T: 20 mm (10 x 10 cm)
H: 150 mm (20 x 20 cm) H: 30 mm (20 x 20 cm)
A: 75 mm (10 x 10 cm)
F: 33 mm (5 x 5 cm)
V: 10 mm (2.5 x 2.5 cm) V: ---
T: 0.015-mm dia.
H: 0.015-mm dia.
A: 0.03-mm dia.
F: 0.03-mm dia.
V: 1.0-mm dia.
A: 15 mm (10 x 10 cm)
F: 5 mm (5 x 5 cm)
E32-DC200E
T: 20 mm (2.5 x 2.5 cm) T: 4.8 mm (2.5 x 2.5 cm) T: 0.015-mm dia.
H: 36 mm (5 x 5 cm) H: 7.2 mm (5 x 5 cm) H: 0.015-mm dia.
A: 18 mm (2.5 x 2.5 cm) A: 3.6 mm (2.5 x 2.5 cm) A: 0.03-mm dia.
F: 8 mm (2.5 x 2.5 cm)
V: 2 mm (2.5 x 2.5 cm)
F: 1.5 mm (2.5 x 2.5 cm) F: 0.03-mm dia.
V: --- V: 1.0-mm dia.
E32-DC200F
E32-DC200F4
T: 20 mm (2.5 x 2.5 cm) T: 4.8 mm (2.5 x 2.5 cm) T: 0.015-mm dia.
H: 36 mm (5 x 5 cm) H: 7.2 mm (5 x 5 cm) H: 0.015-mm dia.
A: 18 mm (2.5 x 2.5 cm) A: 3.6 mm (2.5 x 2.5 cm) A: 0.03-mm dia.
F: 8 mm (2.5 x 2.5 cm)
V: 2 mm (2.5 x 2.5 cm)
M3 screw
M6 screw
F: 1.5 mm (2.5 x 2.5 cm) F: 0.03-mm dia.
V: ---
V: 1.0-mm dia.
E32-D11
T: 60 mm (10 x 10 cm)
H: 90 mm (10 x 10 cm)
A: 45 mm (5 x 5 cm)
T: 13 mm (10 x 10 cm)
H: 20 mm (10 x 10 cm)
A: 10 mm (5 x 5 cm)
F: 5 mm (2.5 x 2.5 cm)
V: ---
T: 0.015-mm dia.
H: 0.015-mm dia.
A: 0.03-mm dia.
F: 0.03-mm dia.
V: 0.5-mm dia.
Flexible (resists
breaking)
F
20 mm (2.5 x 2.5 cm)
V: 7 mm (2.5 x 2.5 cm)
6
E3X
E3X
Model
Appearance
Sensing distance (standard object)
(T: E3X-Tjj H: E3X-H11; A: E3X-Ajj;
F: E3X-Fjj; V: E3X-VGjj)
Min. sensing object
(copper wire)
Features
;
White paper
Black paper
T: 1.6 mm (2.5 x 2.5 cm) T: 0.015-mm dia.
H: 0.015-mm dia.
A: 1.5 mm (2.5 x 2.5 cm) A: 0.03-mm dia.
E32-D21
T: 8 mm (2.5 x 2.5 cm)
H: 14 mm (2.5 x 2.5 cm) H: 3 mm (2.5 x 2.5 cm)
A: 7 mm (2.5 x 2.5 cm)
F: 3 mm (2.5 x 2.5 cm)
V: 1 mm (2.5 x 2.5 cm)
Flexible (resists
breaking)
M3 screw
F: ---
V: ---
F: 0.03-mm dia.
V: 1.0-mm dia.
E32-DC200C
T: 30 mm (5 x 5 cm)
H: 44 mm (5 x 5 cm)
A: 22 mm (2.5 x 2.5 cm) A: 4.5 mm (2.5 x 2.5 cm) A: 0.03-mm dia.
F: 10 mm (2.5 x 2.5 cm) F: ---
V: 2.5 mm (2.5 x 2.5 cm) V: ---
T: 6 mm (5 x 5 cm)
H: 10 mm (5 x 5 cm)
T: 0.015-mm dia.
H: 0.015-mm dia.
Flexible spiral
cord
**
M6 screw
F: 0.03-mm dia.
V: 1.0-mm dia.
E32-DC200D
E32-DC200D4
T: 30 mm (5 x 5 cm)
H: 44 mm (5 x 5 cm)
A: 22 mm (2.5 x 2.5 cm) A: 4.5 mm (2.5 x 2.5 cm) A: 0.03-mm dia.
T: 6 mm (5 x 5 cm)
H: 10 mm (5 x 5 cm)
T: 0.015-mm dia.
H: 0.015-mm dia.
Flexible spiral
cord
**
M6 screw
F: 10 mm (2.5 x 2.5 cm) F: ---
V: 2.5 mm (2.5 x 2.5 cm) V: ---
F: 0.03-mm dia.
V: 1.0-mm dia.
E32-DC9G
E32-DC9G4
T: 35 mm (5 x 5 cm)
H: 60 mm (10 x 10 cm)
A: 30 mm (5 x 5 cm)
F: 9 mm (2.5 x 2.5 cm)
V: 2.5 mm (2.5 x 2.5 cm) V: ---
T: 6 mm (2.5 x 2.5 cm) T: 1.3 mm (2.5 x 2.5 cm) T: 0.015-mm dia.
H: 10 mm (2.5 x 2.5 cm) H: 2 mm (2.5 x 2.5 cm)
A: 5 mm (2.5 x 2.5 cm) A: ---
F: 1.8 mm (2.5 x 2.5 cm) F: ---
V: --- V: ---
T: 7 mm (5 x 5 cm)
H: 12 mm (10 x 10 cm)
A: 6 mm (5 x 5 cm)
F: 1.5 mm (2.5 x 2.5 cm) F: 0.03-mm dia.
V: 1.0-mm dia.
T: 0.015-mm dia.
H: 0.015-mm dia.
A: 0.03-mm dia.
Stainless steel
sleeve
1.2-mm dia.
**
E32-D33
Super-thin; detail
sensing
H: 0.015-mm dia.
A: 0.015-mm dia.
F: 0.03-mm dia.
V: ---
3-mm dia.
0.8-mm dia.
E32-CC200
E32-D32
T: 100 mm (10 x 10 cm) T: 20 mm (10 x 10 cm)
H: 150 mm (20 x 20 cm) H: 30 mm (20 x 20 cm)
T: 0.015-mm dia.
H: 0.015-mm dia.
A: 0.03-mm dia.
F: 0.03-mm dia.
V: 0.5-mm dia.
Coaxial;
positioning
accuracy
M6 screw
A: 75 mm (10 x 10 cm)
F: 33 mm (5 x 5 cm)
A: 15 mm (10 x 10 cm)
F: 6 mm (5 x 5 cm)
V: 10 mm (2.5 x 2.5 cm) V: 2 mm (2.5 x 2.5 cm)
T: 30 mm (2.5 x 2.5 cm) T: 5.3 mm (2.5 x 2.5 cm) T: 0.015-mm dia.
General-purpose
General-purpose
H: 40 mm (5 x 5 cm)
A: 20 mm (2.5 x 2.5 cm) A: 4 mm (2.5 x 2.5 cm)
F: 9 mm (2.5 x 2.5 cm)
V: 2.5 mm (2.5 x 2.5 cm) V: ---
H: 8 mm (5 x 5 cm)
H: 0.015-mm dia.
A: 0.03-mm dia.
2-mm dia.
3-mm dia.
F: 1.5 mm (2.5 x 2.5 cm) F: 0.03-mm dia.
V: 0.5-mm dia.
E32-D32L
E32-D14L
E32-D24
T: 60 mm (10 x 10 cm)
H: 80 mm (10 x 10 cm)
A: 40 mm (5 x 5 cm)
T: 10 mm (10 x 10 cm)
H: 16 mm (10 x 10 cm)
A: 8 mm (5 x 5 cm)
T: 0.015-mm dia.
H: 0.015-mm dia.
A: 0.04-mm dia.
F: 1.1-mm dia.
V: 1-mm dia.
F: 11 mm (2.5 x 2.5 cm) F: 4 mm (2.5 x 2.5 cm)
V: 4 mm (2.5 x 2.5 cm)
V: ---
T: 40 mm (5 x 5 cm)
H: 40 mm (5 x 5 cm)
A: 40 mm (5 x 5 cm)
F: 12 mm (2.5 x 2.5 cm)
T: 8 mm (5 x 5 cm)
H: 8 mm (5 x 5 cm)
A: 8 mm (5 x 5 cm)
F: 2 mm (2.5 x 2.5 cm)
T: 0.03-mm dia.
H: 0.03-mm dia.
A: 0.03-mm dia.
F: 0.5-mm dia.
V: 1.0-mm dia.
Side-view;
long distance
6-mm dia.
V: 1.5 mm (2.5 x 2.5 cm) V: ---
T: 15 mm (2.5 x 2.5 cm) T: 2.5 mm (2.5 x 2.5 cm) T: 0.03-mm dia.
H: 15 mm (2.5 x 2.5 cm) H: 2.5 mm (2.5 x 2.5 cm) H: 0.03-mm dia.
A: 15 mm (2.5 x 2.5 cm) A: 2.5 mm (2.5 x 2.5 cm) A: 0.03-mm dia.
Side-view;
save space
2-mm dia.
F: 4 mm (2.5 x 2.5 cm)
V: 1.6 mm (2.5 x 2.5 cm) V: ---
F: ---
F: 0.03-mm dia.
V: 1.0-mm dia.
E32-D12F
T: 50 mm (5 x 5 cm)
H: 50 mm (5 x 5 cm)
A: 50 mm (5 x 5 cm)
F: 20 mm (2.5 x 2.5 cm)
V: 4 mm (2.5 x 2.5 cm)
T: 15 mm (5 x 5 cm)
T: 0.03-mm dia.
H: 0.03-mm dia.
A: 0.03-mm dia.
F: 0.5-mm dia.
V: 0.5-mm dia.
Teflon-cov-
ered***; with
stands chemi
cals and harsh
environments
H: 15 mm (5 x 5 cm)
A: 15 mm (5 x 5 cm)
F: 6 mm (2.5 x 2.5 cm)
V: ---
-
6-mm dia.
-
*Standard object: opaque
**Not trimmable
***Teflon is a registered trademark of the Dupont Company and the Mitsui Dupont Chemical Company for their fluoride resin.
7
E3X
E3X
Model
Appearance
Sensing distance (standard object)
(T: E3X-Tjj H: E3X-H11; A: E3X-Ajj;
F: E3X-Fjj; V: E3X-VGjj)
Min. sensing object
(copper wire)
Features
;
White paper
T: 60 mm (10 x 10 cm)
H: 120 mm (20 x 20 cm) H: 24 mm (20 x 20 cm)
A: 60 mm (10 x 10 cm)
F: 26 mm (5 x 5 cm)
V: 5 mm (2.5 x 2.5 cm)
Black paper
E32-D51
E32-D61
E32-D73
T: 12 mm (10 x 10 cm)
T: 0.03-mm dia.
H: 0.03-mm dia.
A: 0.03-mm dia.
F: 0.03-mm dia.
V: 1.0-mm dia.
Heat-resistive;
resists 150°C
M6 screw
A: 12 mm (10 x 10 cm)
F: 5 mm (5 x 5 cm)
V: ---
T: 45 mm (5 x 5 cm)
H: 45 mm (5 x 5 cm)
A: 45 mm (5 x 5 cm)
F: 20 mm (2.5 x 2.5 cm)
V: 5 mm (2.5 x 2.5 cm)
T: 9 mm (5 x 5 cm)
H: 9 mm (5 x 5 cm)
A: 9 mm (5 x 5 cm)
F: 4 mm (2.5 x 2.5 cm)
V: ---
T: 0.03-mm dia.
H: 0.03-mm dia.
A: 0.03-mm dia.
F: 0.03-mm dia.
V: 1.0-mm dia.
Heat-resistive;
resists 300°C
**
M6 screw
T: 30 mm (5 x 5 cm)
H: 30 mm (5 x 5 cm)
A: 30 mm (5 x 5 cm)
F: 17 mm (2.5 x 2.5 cm)
V: 3 mm (2.5 x 2.5 cm)
T: 6 mm (5 x 5 cm)
H: 6 mm (5 x 5 cm)
A: 6 mm (5 x 5 cm)
F: 3 mm (2.5 x 2.5 cm)
V: ---
T: 0.03-mm dia.
H: 0.03-mm dia.
A: 0.03-mm dia.
F: 0.2-mm dia.
V: 1.0-mm dia.
Heat-resistive;
resists 400°C
**
M4 screw 1.25-mm dia.
E32-R21
/E39-R3
T: 25 to 250 mm
(35-mm dia. min.)
H: 10 to 250 mm
(35-mm dia. min.)
A: 10 to 250 mm
(35-mm dia. min.)
F: 20 to 230 mm
(35-mm dia. min.)
V: ---
---
T: 0.6-mm dia.
H: 0.3-mm dia.
A: 0.3-mm dia.
F: 0.5-mm dia.
V: ---
Transparent
objects sensing
Reflector
E39-R3
M6 screw
E32-R16
/E39-R1
T: 150 to 1,500 mm
(35-mm dia. min.)
H: 150 to 1,500 mm
(35-mm dia. min.)
A: 150 to 1,500 mm
(35-mm dia. min.)
F: 50 to 700 mm
(35-mm dia. min.)
V: ---
---
T: 1.9-mm dia.
H: 0.6-mm dia.
A: 0.6-mm dia.
F: 0.6-mm dia.
V: ---
Transparent
objects sensing
Reflector
E39-R1
E32-L25
T: 3.3 mm (2.5 x 2.5 cm) ---
H: 3.3 mm (2.5 x 2.5 cm)
A: 3.3 mm (2.5 x 2.5 cm)
F: 3.3 mm (2.5 x 2.5 cm)
V: ---
T: 0.015-mm dia.
H: 0.015-mm dia.
A: 0.03-mm dia.
F: 0.5-mm dia.
V: ---
Limited
reflective;
senses wafers
and small
difference in
height
E32-L25A
E32-L25L
E32-L24L
T: 3.3 mm (2.5 x 2.5 cm) ---
H: 3.3 mm (2.5 x 2.5 cm)
A: 3.3 mm (2.5 x 2.5 cm)
F: 3.3 mm (2.5 x 2.5 cm)
V: ---
T: 0.015-mm dia.
H: 0.015-mm dia.
A: 0.03-mm dia.
F: 0.5-mm dia.
V: ---
Limited
reflective;
senses wafers
and small
difference in
height
H: 7.2±1.8 mm
(2.5 x 2.5 cm)
A: 7.2±1.8 mm
(2.5 x 2.5 cm)
F: 7.2±1.0 mm
(2.5 x 2.5 cm)
---
H: 0.015-mm dia.
A: 0.015-mm dia.
F: 0.015-mm dia.
Limited
reflective, long
distance; senses
wafers and small
difference in
height
H: 4±2 mm
---
H: 0.015-mm dia.
A: 0.015-mm dia.
F: 0.015-mm dia.
Limited
reflective, long
distance,
(2.5 x 2.5 cm)
A: 4±2 mm
side-view;
senses wafers
and small
difference in
height
(2.5 x 2.5 cm)
F: 4±2 mm
(2.5 x 2.5 cm)
*Standard object: opaque
**Not trimmable
8
E3X
E3X
Fine Through-beam
Model
Appearance
Sensing distance (standard object)*
Min. sensing object
(opaque objects)
Features
E32-T22S
H: 1,000 mm (1.7-mm dia. min.)
T: 650 mm (1.7-mm dia. min.)
H: 0.5-mm dia.
T: 0.4-mm dia.
General purpose
Side-view
1.7 mm dia.
E32-T24S
E32-T84S
H: 700 mm (1.7-mm dia. min.)
T: 450 mm (1.7-mm dia. min.)
H: 0.5-mm dia.
T: 0.4-mm dia.
3.5 x 3 mm dia.
H: 700 mm (1.7-mm dia. min.)
H: 0.4-mm dia.
Sensing the wafers
in cassettes (Fine,
long beam sensor
resisting 200°C)
*Use the E32-T22S and E32-T24S in combination with the E3X-H11, E3X-T11, or E3X-T21 Amplifier for stable wafer sensing.
Slot Sensors
Model
Appearance
Sensing distance (standard object)*
Min. sensing object
(opaque objects)
Features
E32-G14
10 mm (slot width) (4-mm dia. min.)
T: 0.7-mm dia.
H: 1.0-mm dia.
A: 0.5-mm dia.
F: 0.6-mm dia.
V: 0.6-mm dia.
Slot through-beam;
no optical axis
adjustment required
*Standard object: opaque
Liquid Level Fiber Unit
Liquid Contact Model
Model
Appearance
Standard
sensing object
Sensing object
angle range
Repeat
frequency
Applicable
Amplifier Unit
(see note)
Pure water at a
temperature of
25°C.
E3X-NT/NM
E3X-NV
E3X-H
E32-D82F1
E32-D82F2
±10° max.
0.5 mm max.
Note: When using the E32-D82F1 or E82-D82F2 with the E3X-A, cut the plastic fiber part to 0.5 m, otherwise the energy of the light received
by the E3X-A will be insufficient.
Pipe Mounting Model
Model
Appearance
Standard sensing object
Repeat frequency
1 mm max.
Applicable Amplifier Unit
E32-L25T
Liquid (Non-transparent liquids
may not be sensed)
E3X-NT/NM
E3X-A/H
9
E3X
E3X
High-precision Screen Sensors
Model
Appearance
Slit width
Sensing distance
(H: E3X-H11; A: E3X-Ajj;
F: E3X-Fjj; V: E3X-VGjj)
Min. sensing object*
(horizontal beam)
E32-T16P
Not used
H: 600 mm
A: 300 mm
H: 1.3-mm dia. (1.1-mm dia.)
A: 2.0-mm dia. (0.9-mm dia.)
0.5 mm wide H: 100 mm
A: 50 mm
H: 1.3-mm dia. (0.4-mm dia.)
A: 2.0-mm dia. (0.7-mm dia.)
1.0 mm wide H: 200 mm
A: 100 mm
H: 1.3-mm dia. (0.6-mm dia.)
A: 2.0-mm dia. (0.8-mm dia.)
E32-T16
Not used
H: 1,500 mm
A: 750 mm
F: 330 mm
V: 150 mm
H: 6.0-mm dia.
A: 6.0-mm dia.
F: 7.0-mm dia.
V: 7.0 mm dia.
0.5 mm wide H: 900 mm
A: 450 mm
H: 5.0-mm dia.
A: 5.0-mm dia.
F: 7.0-mm dia.
V: 7.0-mm dia.
F: 120 mm
V: 20 mm
1.0 mm wide H: 1,200 mm
A: 600 mm
H: 6.0-mm dia.
A: 6.0-mm dia.
F: 7.0-mm dia.
V: 7.0-mm dia.
F: 250 mm
V: 60 mm
*
Values not in parentheses represent sensing objects within the 11-mm sensing area and values in parentheses represent sensing objects in
the center of the E32-T16P sensing area. The diameters of sensing objects in the above table represent sensing object sizes, on condition
that the objects are not moving.
Sensing Direction
Sensing
object
Specifications
Amplifier Units
Indicator
Light indicator (red), Stability indicator (green)
8 turns with indicator (except E3X-Tjj)
Reverse polarity, Output short-circuit
Sensitivity adjuster
Circuit protection
Ambient temperature
Operating:–25°C to 55°C (with no icing)
Storage: –40°C to 70°C
Ambient humidity
Ambient illumination
Insulation resistance
Dielectric strength
Enclosure rating
Material
35% to 85% (with no condensation)
Sunlight: 10,000
ȏ
x max.; Incandescent lamp: 3,000 ȏx max.
20 M min. (at 500 VDC)
W
1,000 VAC, 50/60 Hz for 1 min
IEC IP66 (with protective cover in place) (see note)
Case: Heat-resistive ABS; Cover: Polycarbonate
Cord-drawing method
Connection method
Weight (with 2-m cord)
Approx. 100 g
Note: The enclosure rating is IP50 without the protection cover
.
10
E3X
E3X
Fiber Unit
Through-beam (Separate) Sensors
Model
Ambient temperature
Ambient humidity
Permissible
bending radius
Material
Enclosure rating
Operating: –40
(with no icing)
°
C to 70°C Operating: 35% to
E32-T11L
E32-T12L
E32-T21L
E32-T22L
E32-TC200
25 mm min.
Black polyethylene IEC IP67
85%
E32-TC200B
E32-TC200B4
E32-T22
E32-TC200E
E32-TC200F
E32-TC200F4
E32-TC200A
E32-T11
4 mm min.
Vinyl chloride
E32-T21
E32-TC200C
25 mm min.
Black polyethylene
E32-TC200D
E32-TC200D4
E32-T14L
E32-T24
E32-T14
E32-T17L
E32-T12F
Operating: –30
(with no icing)
°
°
°
C to 70°C
C to 70°C
C to
40 mm min.
25 mm min.
35 mm min.
25 mm min.
Teflon-covered
black polyethylene
E32-M21
E32-T51
E32-T61
Operating: –40
(with no icing)
Black polyethylene
Fluoride resin
SUS
Operating: –40
150°C* (with no icing)
Operating: –40 C to
300°C (with no icing)
*When used continuously between –40 C and 130°C.
°
°
11
E3X
E3X
Reflective Sensors
Model
Differential travel
Ambient
temperature
Ambient
humidity
Permissible
bending radius
Material
Enclosure rating
20% of max. of
sensing distance
(Adjustable in a
range of 0% to
20% when the
Operating: –40°C
Operating:
35% to 85%
Black
polyethylene
E32-D11L
E32-D12
25 mm min.
IEC IP67
to 70°C (with no
icing)
E32-D21L
E32-D22L
E32-DC200
E3X-H11 is used.)
E32-DC200B
E32-DC200B4
E32-DC200E
E32-DC200F
E32-DC200F4
E32-D11
4 mm min.
Vinyl chloride
E32-D21
Black
E32-DC200C
25 mm min.
polyethylene
E32-DC200D
E32-DC200D4
E32-DC9G
E32-DC9G4
E32-D33
E32-CC200
E32-D32
E32-D32L
E32-D14L
E32-D24
E32-D12F
Operating: –30°C
to 70 C (with no
icing)
40 mm min.
35 mm min.
25 mm min.
Teflon-covered
black
polyethylene*
°
E32-D51
E32-D61
E32-D73
Operating: –40°C
to 150 C (with no
icing)**
Fluoride resin
°
Operating: –40°C
SUS
to 300°C (with no
icing)
Operating: –40°C
to 400°C (with no
icing)
E32-R21
E39-R3
Operating: –40°C
to 70 C (with no
icing)
Black
polyethylene
°
E32-R16
E39-R1
Operating: –25°C
to 55 C (with no
icing)
IEC IP66
IEC IP50
°
Operating: –40°C
to 70 C (with no
icing)
E32-L25
°
E32-L25A
E32-L25L***
Operating: –40°C
10 mm min.
(average at 10%
decrease of
sensing
Reinforced
polyethylene
to 105°C (with no
icing)
E32-L24L***
distance)
*Teflon is a registered trademark of the Dupont Company and the Mitsui Dupont Chemical Company for their fluoride resin.
**When used continuously between –40
***Beam size: 2 mm dia.
°C and 130°C.
12
E3X
E3X
Fine Through-beam Sensors
Model
Beam size
Differencial Horizontal
Ambient
temperature
Ambient
humidity
Permissible
bending
radius*
Material
Enclosure
rating
travel
positioning
accuracy
13 mm dia. (at
a distance of
200 mm)
Operating:
–40°C to 70°C 35% to 85%
(with no icing)
Operating:
Reinforced
laminated
vinyl chloride
E32-T22S
E32-T24S
E32-T84S
---
---
10 mm min.
IEC IP67
Operating:
–40°C to
25 mm min.
SUS
200°C (with no
icing)
*Average at 30% of sensing distance
Slot Sensors
Model
E32-G14
Ambient temperature
Ambient humidity
Permissible
bending radius
Material
Enclosure rating
Operating: –40°C to 70°C Operating: 35% to
25 mm min.
Black polyethylene IEC IP67
(with no icing)
85%
Liquid Contact Model
Model Differencial
Ambient
temperature
Ambient
humidity
Ambient
pressure
Permissible
bending radius*
Material
Enclosure
rating
travel
(average at 10%
of sensing
distance)
Teflon part within
1.5 m of fiber tip:
–40°C to 200°C
(with no icing)
40 mm min. (plastic
fiber: 25 mm min.)
Sensing head:
–50 kpa
(–0.49 kgf/cm
to 500 kpa
(4.9 kgf/cm
E32-D82F1 3.0 mm max.
Operating:
35% to 85%
IEC IP68**
2
Teflon* (PFA)
)
Bending-prohibited
part:
E32-D82F1:
Within 150 mm of
fiber tip
E32-D82F2:
Within 350 mm of
fiber tip
Fiber sheath:
Black
polyethylene
2
)
Parts other than
above:
–40°C to 85°C
Connector:
Nickel-coated
brass
E32-D82F2
(with no icing)
*The teflon part located 10 cm underwater must not generate air bubbles when air is injected into the teflon part with a pressure of 98 kpa
2
(1 kgf/cm ).
**Teflon is a registered trademark of the Dupont Company and the Mitsui Dupont Chemical Company for their fluoride resin.
Pipe Mounting Model
Model
Suitable pipe
Pipe material
Ambient
temperature
Ambient
humidity
Permissible
bending
radius
Material
Enclosure
rating
Transparent pipes
with an outer
diameter of 8 to
10 mm and an
inner diameter of
6 to 8 mm
E32-L25T
FEP
Operating:
–40°C to 70°C 35% to 85%
(with no icing)
Operating:
10 mm min.
Sensing head:
Polycarbonate
IEC IP50
transparent
pipes or
equivalent
Fiber:
Polyethylene-
covered plastic
High-precision Screen Sensors
Model
Ambient temperature
Ambient humidity
Permissible
bending radius
Material
Enclosure rating
Operating: –40
(with no icing)
°C to 70°C Operating: 35% to
85%
E32-T16P
R10 mm min.
Sensing head:
Heat-resistive ABS
Fiber sheath:
IEC IP50
Vinyl chloride
E32-T16
25 mm min.
Sensing head:
Heat-resistive ABS
Sensing surface:
PMMA
IEC IP67
Fiber sheath:
Black polyethylene
13
E3X
E3X
Attachments
Name
Small Spot Lens Unit
Long Distance Lens Unit
Applications
Sensing over
0.5-mm-dia. spots
Increasing sensing distance
Model
E39-F3A
E39-F1
Reflective
Appearance
Through-beam
(separate)
Applicable fibers
E32-D32
20 mm
E32-T11L
1,200 mm
E32-TC200
E32-T61
E32-T11
E32-TC200C
With
Sensing distance
2,000 mm
1,300 mm
800 mm
1,600 mm
800 mm
350 mm
100 mm
E3X-Tjj
With
Standard object
Sensing distance
Standard object
Sensing distance
Standard object
Sensing distance
Standard object
Sensing distance
White paper 2.5 x 2.5 cm Opaque objects: 4-mm dia. min.
20 mm 2,000 mm 3,000 mm
White paper 2.5 x 2.5 cm Opaque objects: 4-mm dia. min.
20 mm 1,000 mm 1,500 mm
White paper 2.5 x 2.5 cm Opaque objects: 4-mm dia. min.
16 mm 550 mm 670 mm*
White paper 2.5 x 2.5 cm Opaque objects: 4-mm dia. min.
2,000 mm
1,000 mm
400 mm
E3X-H11
With
E3X-Ajj
With
E3X-Fjj
With
---
---
---
120 mm
Opaque objects: 4-mm dia. min.
5° to 40
190 mm**
120 mm
E3X-VGjj Standard object
Directivity
°
Differential travel
20% of sensing distance ---
Ambient temperature
Operating: –40°C to
Operating: –40°C to 200°C (Do not exceed the operating
70°C
temperature of the fiber.)
Material
Shaft
Aluminum
Brass
Lens
Optical glass
Base
---
---
Reflector
*E32-T6: 450 mm.
**E32-T6: 130 mm.
Name
Side-view Unit
Applications
Model
Changing the sensing direction at °90
E39-F2
Appearance
Through-beam
(separate)
Applicable fibers
E32-T11L
250 mm
E32-TC200
250 mm
E32-T61/11
200 mm
E32-TC200C
100 mm
With
Sensing distance
E3X-Tjj
With
Standard object
Sensing distance
Standard object
Sensing distance
Standard object
Sensing distance
Standard object
Sensing distance
Opaque objects: 3-mm dia. min.
400 mm 500 mm
Opaque objects: 3-mm dia. min.
200 mm 250 mm
Opaque objects: 3-mm dia. min.
60 mm 100 mm
Opaque objects: 3-mm dia. min.
400 mm
200 mm
60 mm
10 mm
200 mm
100 mm
30 mm
6 mm
E3X-H11
With
E3X-Ajj
With
E3X-Fjj
With
10 mm
19 mm
E3X-VGjj Standard object
Opaque objects:
4-mm dia. min.
Opaque objects: 3-mm dia. min.
Directivity
20° to 60°
Differential travel
Ambient temperature
---
Operating: –40°C to 200°C (Do not exceed the operating temperature of the fiber.)
Material
Shaft
Brass
Lens
Optical glass
Base
---
---
Reflector
14
E3X
E3X
Name
Lens-equipped Reflective Unit
Applications
Model
Converting through-beam sensors to reflective sensors
E39-F3
Appearance
Reflective
Applicable fibers
E32-T11L
E32-TC200
E32-T61
With
Sensing distance
White paper 55 to 150* mm (20 x 20 cm) 85 to 100 mm (20 x 20* cm)
E3X-Tjj
(standard object)
Black paper ---
15 to 17*mm (20 x 20 cm)
16 to 18*mm (20 x
20 cm)
With
Sensing distance
(standard object)
White paper 10 to 300 mm (20 x 20 cm)
Black paper ---
35 to 180 mm (20 x 20 cm)
5 to 120 mm (20 x 20 cm)
E3X-H11
5 to 80 mm (20 x
20 cm)
With
Sensing distance
(standard object)
White paper 10 to 150 mm (20 x 20 cm)
Black paper ---
35 to 90 mm (10 x 10 cm)
5 to 60 mm (10 x 10 cm)
E3X-Ajj
5 to 40 mm (10 x
10 cm)
With
Sensing distance
(standard object)
Sensing distance
White paper 10 to 65 mm (10 x 10 cm)
Black paper ---
20 to 40 mm (5 x 5 cm)
10 to 20 mm (5 x 5 cm)
20 to 35 mm (5 x 5 cm)
---
E3X-Fjj
With
White paper ---
10 to 15 mm (2.5 x 2.5 cm) ---
E3X-VGjj (standard object)
Directivity
Black paper ---
---
Differential travel
20% of sensing distance
Ambient temperature
Operating: –40°C to 200°C (Do not exceed the operating temperature of the fiber.)
Material
Shaft
Brass
Lens
Optical glass
Aluminum
---
Base
Reflector
*These values are possible when the angle of the E39-F3 is smallest (parallel).
15
E3X
E3X
Name
Lens-equipped Reflective Unit
Side-view Reflective
Unit
Applications
Converting through-beam sensors to reflective
sensors
Converting
through-beam to
reflective sensor
Model
E39-F3
E39-F5
Appearance
Reflective
Reflective
Applicable fibers
E32-T11
E32-TC200C
E32-TC200A
With
Sensing distance
(standard object)
White paper 90 to 100* mm (20 x
85 to 100* mm (20 x
20 cm)
5 to 30* mm (10 x 10 cm)
20 cm)
E3X-Tjj
With
Black paper ---
6 to 9* mm (10 x 10 cm)
60 mm (10 x 10 cm)
Sensing distance
(standard object)
Sensing distance
(standard object)
Sensing distance
(standard object)
Sensing distance
White paper 35 to 180 mm (20 x 20 cm)
Black paper 5 to 70 mm (20 x 20 cm)
White paper 35 to 90 mm (10 x 10 cm)
Black paper 5 to 35 mm (10 x 10 cm)
White paper 20 to 40 mm (5 x 5 cm)
Black paper ---
E3X-H11
With
10 to 60 mm (20 x 20 cm) 5 to 20 mm (10 x 10 cm)
30 mm (5 x 5 cm)
E3X-Ajj
With
10 to 30 mm (10 x 10 cm) 5 to 10 mm (5 x 5 cm)
20 to 35 mm (5 x 5 cm)
13 mm (2.5 x 2.5 cm)
E3X-Fjj
With
---
---
White paper ---
E3X-VGjj (standard object)
Directivity
Black paper ---
---
Differential travel
20% of sensing distance
Ambient temperature
Operating: –40°C to 200°C (Do not exceed the
Operating: –40°C to
operating temperature of the fiber.)
70°C
Material
Shaft
Brass
---
Lens
Optical glass
Aluminum
---
---
Base
Brass
Stainless
Reflector
*These values are possible when the angle of the E39-F3 is smallest (parallel).
Beam Spot Characteristics
E39-F3A
O: Spot diameter
(mm)
d
ȏ
Fiber
E32-D32
1.5
1.0
0.8
0.5
Insertion distance
ȏ
(mm)
16
E3X
E3X
Spiral Tubes
Model
E39-F32A5 E39-F32A E39-F32B5 E39-F32B E39-F32C5 E39-F32C E39-F32D5 E39-F32D
L
Appearance
End cap
Tube
Head connector
Length (L)
500 mm
1,000 mm
500 mm
E32-TC200E
1,000 mm
500 mm
E32-TC200
1,000 mm
500 mm
1,000 mm
Applicable fiber
E32-DC200E
E32-DC200
E32-DC200F(4)
E32-D21
E32-TC200F(4)
E32-T21
E32-T21L
E32-TC200B(4)
E32-T11
E32-T51
E32-DC200B(4)
E32-CC200
E32-D11
E32-T11L
E32-D51
E32-D11L
Ambient temperature
Ambient humidity
Operating: –40°C to 150°C (Do not exceed the operating temperature of the fiber)
Operating: 35% to 85%
R: 30 mm min.
Permissible bending
radius
Tensile strength
Between head connector and end cap with tube: 15 kgf
ube: 20 kgf cm max. (2 N m)
$ cm max. (1.5 N $ m)
T
$
$
Compression load
Tube: 3 kg max. (29.4 N)
Accessories
Name
Fiber Cutter
E39-F4
Fine-fiber Attachment
E39-F9
Fiber Connector
E39-F10
Sleeve Bender
Model
E39-F11
Appearance
Features
Used to cut fibers to
desired lengths
Used when inserting fine Used to connect fibers
Used to bend fiber
sleeves
fibers into the amp
when broken
Applicable fiber
All models equipped with E32-DC200E, -TC200E
E32-DC200, -TC200
E32-DC200B(4),
-TC200B(4)
E32-TC200B(4)
E32-TC200D(4)
E32-DC200F(4),
-TC200F(4)
trimmable fibers
E32-DC200F(4),
-TC200F(4)
E32-D21, -D21L, -D22L
E32-T21, -T21L, -T22L
E32-D32, -T22
E32-D24. -T24
E32-D33
E32-TC200A
E32-T14, -G14
E32-D11L, -T11L, -T12L
E32-D14L, -T14L
E32-T17L
E32-DC9G(4)
E32-R21
17
E3X
E3X
Engineering Data
Excess Gain Ratio
E3X-Tjj
E32-TC200
E32-T11L
E32-T11L + E39-F1
Sensing distance
Sensing distance
Sensing distance
Sensing distance (mm)
Sensing distance (mm)
Sensing distance (m)
E32-T11L + E39-F2
E32-T11L + E39-F3
E32-T21L
(When the angle of the E39-F3 is at
its minimum (parallel).)
Sensing
object
Sensing distance
Sensing distance
Sensing
distance
Sensing distance (mm)
Sensing distance (mm)
Sensing distance (mm)
E32-T14L
E32-T17L
E32-T16
Sensing distance
Sensing distance
Sensing distance
Sensing distance (mm)
Sensing distance (m)
Sensing distance (m)
18
E3X
E3X
E32-DC200
E32-D11L
E32-D21L
Sensing distance
Sensing distance
Sensing distance
Sensing
object
Sensing
object
Sensing
object
Sensing distance (mm)
Sensing distance (mm)
Sensing distance (mm)
E3X-H11
E32-TC200
E32-TC200 + E39-F1
E32-T11L
Sensing distance
Sensing distance
Sensing distance
Sensing distance (mm)
Sensing distance (m)
Sensing distance (mm)
E32-T11L + E39-F1
E32-T11L + E39-F2
E32-T11L + E39-F3
Sensing distance
Sensing
object
Sensing distance
Sensing distance
Sensing distance (m)
Sensing distance (mm)
Sensing distance (mm)
19
E3X
E3X
E32-T21L
E32-T14L
E32-T17L
Sensing distance
Sensing distance
Sensing distance
Sensing distance (mm)
Sensing distance (mm)
Sensing distance (m)
E32-T16
E32-T22S
E32-T24S
Sensing distance
Sensing distance
Sensing distance
Sensing distance (m)
Sensing distance (mm)
Sensing distance (mm)
E32-DC200
E32-D11L
E32-D21L
Sensing distance
Sensing distance
Sensing distance
Sensing
object
Sensing
object
Sensing distance (mm)
Sensing distance (mm)
Sensing distance (mm)
20
E3X
E3X
E32-T84S
Sensing distance
Sensing distance (mm)
E3X-Ajj/-Fjj/-VGjj
E32-T11L, E32-T12L
E32-T11L + E39-F1
E32-T11L + E39-F2
Sensing distance
Sensing distance
Sensing distance
E3X-Aj
E3X-Aj
E3X-Aj
E3X-Fj
E3X-Fj
E3X-Fj
Operating
level
E3X-VGj
Operating level
Operating level
E3X-VGj
E3X-VGj
Sensing distance (mm)
Sensing distance (cm)
Sensing distance (mm)
E32-T11L + E39-F3
E32-T21L, E32-T22L
E32-T14L
Sensing distance
Sensing distance
Sensing object
Sensing distance
E3X-Aj
E3X-Aj
E3X-Aj
E3X-Fj
E3X-Fj
E3X-Fj
Operating level
Operating level
Operating level
E3X-VGj
E3X-VGj
Sensing distance (mm)
Sensing distance (mm)
Sensing distance (mm)
21
E3X
E3X
E32-T17L
E32-T12F
E32-D11L
Sensing distance
Sensing distance
Sensing distance
Sensing object
E3X-Aj
E3X-Aj
E3X-Aj
E3X-Fj
E3X-Fj
E3X-Fj
Operating level
Operating level
Operating level
E3X-VGj
E3X-VGj
E3X-VGj
Sensing distance (m)
Sensing distance (cm)
Sensing distance (mm)
E32-D21L, E32-D22L
E32-D14L
E32-D12F
Sensing distance
Sensing object
Sensing distance
Sensing distance
Sensing object
Sensing
object
E3X-Aj
E3X-Aj
E3X-Aj
E3X-Fj
E3X-Fj
E3X-Fj
Operating level
Operating level
Operating level
E3X-VGj
E3X-VGj
E3X-VGj
Sensing distance (mm)
Sensing distance (mm)
Sensing distance (mm)
Operating Range
E3X-Tjj
E32-DC200
E32-D11L
X
X
Y
Y
Set distance
X (mm)
Set distance
X (mm)
E32-D21L
X
Y
Set distance
X (mm)
22
E3X
E3X
E3X-H11
E32-T11L + E39-F3
E32-DC200
E32-D11L
Set distance
X (mm)
Set distance
X (mm)
Set distance
X (mm)
Sensing object
Sensing object
Sensing object
E32-D12
E32-D21L
E32-DC200E
Set distance
X (mm)
Set distance
X (mm)
Set distance
X (mm)
Sensing object
Sensing object
Sensing object
E32-D21
E32-D11
E32-CC200
Set distance
X (mm)
Set distance
X (mm)
Set distance
X (mm)
Sensing object
Sensing object
Sensing object
E32-D32
E32-D32L
E32-D33
Set distance X (mm)
Set distance
X (mm)
Set distance
X (mm)
E32-D51
E32-L25L
E32-T84S
Set distance
X (mm)
Set distance
X (mm)
Set distance
X (mm)
Operating
position Y
Sensing object
Sensing object Set distance X
Sensing
object
Set distance X
23
E3X
E3X
E3X-Ajj/-Fjj/-VGjj
E32-T11L + E39-F3
E32-DC200
E32-D11L
E3X-VGj
E3X-Fj
E3X-Aj
E3X-Aj
E3X-Aj
E3X-Fj
E3X-Fj
Set distance
X (mm)
Set distance
X (mm)
Set distance
X (mm)
Sensing object
Sensing object
Sensing object
Note: With E3X-A: Adjust the angle of
E39-F3 so that the sensor can
sense an object at a distance of
90 mm. (For E3X-F: 50 mm)
E32-D12
E32-D21L + E32-D22L
E32-DC200E
E3X-Aj
Amplifier
E3X-VGj Amplifier
E3X-Aj
E3X-Fj
E3X-Aj
E3X-Fj Amplifier
Set distance
X (mm)
Set distance
X (mm)
Set distance
X (mm)
Sensing object
Sensing object
Sensing object
E32-D21
E32-D11
E32-D33
E3X-VGj
E3X-Aj
E3X-Aj
E3X-Fj
E3X-Aj
Set distance
X (mm)
Set distance
X (mm)
Set distance
X (mm)
Sensing object
Sensing object
E32-CC200
E32-D32L
E32-D14L
E3X-VGj
E3X-VGj Amplifier
E3X-Aj
E3X-Fj
E3X-Aj
E3X-Fj
Amplifier
E3X-Aj Amplifier
E3X-Fj
Set distance
X (mm)
Set distance
X (mm)
Set distance
X (mm)
Sensing object
24
E3X
E3X
E32-D24
E32-D12F
E32-D51
E3X-Aj
E3X-VGj
E3X-Fj
E3X-Fj
E3X-Aj
E3X-Aj
E3X-Fj
Set distance
X (mm)
Set distance
X (mm)
Set
distance X
(mm)
Sensing object
Sensing object
E32-D61
E32-D73
E32-R16
E3X-Aj
E3X-Fj
E3X-Aj
E3X-Aj
E3X-Fj
Set distance
X (mm)
Set distance
X (mm)
Set distance X (mm)
Sensing
object
Sensing object
Sensing object
E32-L25L
Set distance
X (mm)
Operating
position Y
Sensing object
Sensing object Set distance X
Set distance X
25
E3X
E3X
Parallel Operating Range (Typical)
E3X-Tjj
E32-TC200
E32-T11L
X
X
Y
Y
Set distance
X (mm)
Set distance
X (mm)
E32-T11L +E39-F1
E32-T11L + E39-F2
X
Y
X
Y
Set distance X (m)
Set
distance
X (mm)
E32-T21L
E32-T14L
X
Y
X
Y
Set
distance
X (mm)
Set distance
X (mm)
E32-T17L
E32-T12F
X
Y
X
Y
Set distance
X (m)
Set
distance
X (m)
26
E3X
E3X
E3X-H11
E32-TC200
E32-TC200 + E39-F2
E32-T11L
Set distance
X (mm)
Set distance
X (mm)
Set distance
X (mm)
E32-T11L + E39-F1
E32-T11L + E39-F2
E32-T21L
Set distance
X (mm)
Set distance
X (mm)
Set distance
X (mm)
E32-T21L
E32-T21
E32-T14
E32-T22
E32-T11
E32-T24
E32-T12F
Set distance
X (mm)
Set distance
X (mm)
Set
distance
X (mm)
E32-T14L
Set distance
X (mm)
Set distance
X (mm)
Set distance
X (mm)
E32-T17L
Set distance
X (mm)
Set distance
X (mm)
Set distance
X (mm)
27
E3X
E3X
E32-M21
E32-T51
E32-T61
Set distance
X (mm)
Set
distance X
(mm)
Set distance
X (mm)
E32-T22S
E32-T24S
Set distance
X (mm)
Set distance
X (mm)
E3X-Ajj/-Fjj/-VGjj
E32-TC200
E32-TC200 + E39-F2
E32-T11L/-T12L
E3X-Aj
E3X-Aj
E3X-VGj
E3X-VGj
E3X-Aj
E3X-Fj
E3X-Fj
Set distance
X (mm)
Set distance
X (mm)
Set distance
X (mm)
E32-T11L + E39-F1
E32-T11L + E39-F2
E32-T21L/-T22L
E3X-Aj
E3X-Aj
E3X-VGj
E3X-Fj
E3X-Aj
E3X-VGj
E3X-VGj
E3X-Fj
E3X-Fj
Set distance
X (mm)
Set
Set distance
X (mm)
distance
X
(mm)
28
E3X
E3X
E32-TC200E
E32-T11
E32-T21
E32-T14
E32-M21
E3X-VGj
E3X-Aj
E3X-Aj
E3X-VGj
E3X-Aj
E3X-Fj
E3X-Fj
E3X-Fj
Set distance
X (mm)
Set distance
X (mm)
Set
distance X
(mm)
E32-T14L
E32-T24
E3X-VGj
E3X-Aj
E3X-Aj
E3X-Fj
E3X-VGj
E3X-Fj
E3X-Aj
Set distance
X (mm)
Set distance
X (mm)
Set distance
X (mm)
E32-T17L
E32-T12F
E3X-Aj
E3X-Aj
E3X-Aj
E3X-F21
E3X-VGj
E3X-Fj
E3X-VGj
E3X-Fj
Set distance
X (mm)
Set distance
X (mm)
Set
distance
X
(mm)
E32-T51
E32-T61
E32-T61 + E39-F1
E3X-Aj
E3X-Aj
E3X-Aj
E3X-Fj
Set distance
X (mm)
Set distance
X (mm)
Set distance
X (mm)
E32-T22S
E32-T24S
E3X-Aj
E3X-Aj
E3X-VGj
E3X-VGj
E3X-Fj
E3X-Fj
Set distance X (mm)
Set distance X (mm)
29
E3X
E3X
Number of Turns of Sensitivity
Adjuster and Sensing Distance (Typical)
E3X-H/E32-D11L
E3X-A, -F/E32-D11L
Sensing Object: White Paper of 10 x 10 cm
with E3X-A and 5 x 5 cm with E3X-F
Sensing Object: White Paper of 5 x 5 cm
E3X-Aj
E3X-Fj
Sensitivity adjuster
Sensitivity adjuster
Color Sensing (Typical)
Green Light Source E3X-VGj /E32-D11L
The following graph shows the relationship between colors and the
number of turns of the sensitivity adjustor when the E32-D11L is in
operation with the sensing distance adjusted to 5 mm.
Munsell chroma (MC)
White CM484
Yellow CM124
5 mm
Amber CM 78
10°
Yellow green CM157
Orange CM 85
Aqua CM263
Red CM 6
Purple CM379
Magenta CM431
Blue CM336
Green CM241
Black CM489
Number of turns
30
E3X
E3X
Nomenclature
E3X-Tjj
E3X-H11
Stable Operation
Indicator (Green Indicator)
Light Reception
Indicator (Red
Indicator)
Stable Operation
Indicator (Green Indicator)
Light Reception
Indicator (Red
Indicator)
Tuning Indicator (Two
Sensitivity Indicator
The position of the indicator
can be checked.
Colors: red/green indicator)
Tuning Button
8-turn Sensitivity Adjuster
Mode Setting Selector
Hysteresis Adjuster
T
imer Switch
ON: imer function
is ON.
T
imer Switch
ON: imer function
is ON.
T
T
Mode Selector
SET: The light source
flashes. Set to this
Operation Mode Selector
L-ON: Output transistor is ON
when light is received.
D-ON: Output transistor is ON
when light is not received.
OFF: Timer function
is OFF.
OFF: Timer function
is OFF.
mode to adjust the
light axis.
L-ON: Output transistor is ON
when light is received.
D-ON: Output transistor is ON
Light Reception
Monitoring Terminal
(see note)
Light Reception
Monitoring Terminal
Monitoring is used
with the E39-VX Beam
Checker
Monitoring is used
with the E39-VX
Beam Checker
when light is not re
ceived.
-
Note: The light reception monitoring terminal is not available with the E3X-T11.
E3X-A11/-A41
E3X-VG11
E3X-A21/-A51
E3X-F21/-F51
E3X-VG21
Light Reception
Stable Operation
Light Reception
Indicator (Red
Indicator)
Stable Operation
Indicator (Green
Indicator)
Indicator (Red In
-
Indicator (Green Indicator)
dicator)
Sensitivity Indicator
Sensitivity Indicator
Sensitivity adjustment
can be checked visually.
8-turn Sensitivity
Adjuster
8-turn Sensitivity
Adjuster
Timer Adjuster
T
imer Switch
ON: imer function
is ON.
T
OFF: Timer function
is OFF.
Mode Selector
SET: The light source
flashes. Set to this
mode to adjust the
light axis.
L-ON: Output transistor is ON
when light is received.
D-ON: Output transistor is ON
Light Reception
Monitoring Terminal
Monitoring is used
with the E39-VX Beam
Checker
Light Reception
Monitoring Terminal
Monitoring is used
with the E39-VX
Beam Checker
Mode Selector
SET: The light source
flashes. Set to this
mode to adjust the
light axis.
L-ON: Output transistor is ON
when light is received.
D-ON: Output transistor is ON
when light is not re
ceived.
Note: Set the mode selector to L-ON or D-ON after the
-
when light is not re
ceived.
-
light axis is adjusted.
31
E3X
E3X
Operation
Output Circuits
Type
Model
Mode
switch
Output
transistor
Output circuit
NPN
E3X-T21
Light ON
Dark ON
Light ON
ON when light
is received.
Light
(red)
Tuning (red/
green)
Stability
(green)
Brown
Load
Black
Load
Orange
Control output
Main
circuit
Z
D
Self-diagnostis
output
Z
D
ON when light
is not received.
Blue
Remote tuning
input
Pink
Remote bank
selection input
Purple
Z
: V = 39 V
Z
D
Brown
Black
E3X-T11
E3x-H11
E3X-A11
E3X-VG11
ON when light
is received.
Light
(red)
Stability
(green)
Load
Main
circuit
100 mA max.
Z
D
Dark ON
Light ON
ON when light
is not received.
Blue
Z
: V = 39 V
Z
D
E3X-A21
E3X-VG21
E3X-F21
ON when light
is received.
Light
(red)
Stability
(green)
Brown
Load
(Relay)
Load
(Relay)
Black
D
Main
circuit
Control
output
Z
Self-diagno-
sis output
Orange
Z
Dark ON
ON when light
is not received.
D
External-
check input
Pink
Blue
10 K
Z
: V = 39 V
Z
D
PNP
E3X-A41
Light ON
Dark ON
Light ON
ON when light
is received.
Brown
Light
(red)
Stability
(green)
Z
D
Black
Main
circuit
100 mA max.
ON when light
is not received.
Load
Blue
Z
: V = 39 V
Z
D
E3X-A51
E3X-F51
ON when light
is received.
Brown
10 K
External-check
input
Self-diagno-
sis output
Light
(red)
Stability
(green)
Z
Pink
D
Orange
Control
output
Z
D
Main
circuit
Dark ON
ON when light
is not received.
Load
(Relay)
Black
Load
(Relay)
Blue
V = 39 V
Z
Z
D :
32
E3X
E3X
Timing Charts
Type
Model
Mode
switch
Output
transistor
Timing chart
Light received
Light not received
NPN
E3X-T21
Light ON
Dark ON
Light ON
Dark ON
Light ON
Dark ON
ON when light
is received.
T
ON
OFF
Light indicator
(Red)
Output
transistor
ON
OFF
Load
(relay)
Operate
Release
(Between brown and black)
Light received
Light not received
ON when light
is not received.
ON
OFF
Light indicator
(Red)
T
Output
transistor
ON
OFF
Load
(relay)
Operate
Release
(Between brown and black)
Light received
Light not received
E3X-T11
E3X-H11
E3X-A11
E3X-VG11
ON when light
is received.
ON
OFF
Light indicator
(Red)
Output
transistor
ON
OFF
Load
(relay)
Operate
Release
(Between brown and black)
Light received
Light not received
ON when light
is not received.
ON
OFF
Light indicator
(Red)
Output
transistor
ON
OFF
Load
(relay)
Operate
Release
(Between brown and black)
Light received
Light not received
E3X-A21
E3X-VG21
E3X-F21
ON when light
is received.
T
ON
OFF
Light indicator
(Red)
Output
transistor
ON
OFF
Load
(relay)
Operate
Release
(Between brown and black)
Light received
Light not received
ON when light
is not received.
ON
OFF
Light indicator
(Red)
T
Output
ON
transistor
OFF
Load
(relay)
Operate
Release
(Between brown and black)
33
E3X
E3X
Type
PNP
Model
E3X-A41
Mode
switch
Output
transistor
Timing chart
Light received
Light not received
Light ON
Dark ON
Light ON
Dark ON
ON when light
is received.
ON
OFF
Light indicator
(Red)
Output
transistor
ON
OFF
Load
(relay)
Operate
Release
(Between blue and black)
Light received
Light not received
ON when light
is not received.
ON
OFF
Light indicator
(Red)
Output
transistor
ON
OFF
Load
(relay)
Operate
Release
(Between blue and black)
Light received
Light not received
E3X-A51
E3X-F51
ON when light
is received.
T
ON
OFF
Light indicator
(Red)
Output
transistor
ON
OFF
Load
(relay)
Operate
Release
(Between blue and black)
Light received
Light not received
ON when light
is not received.
ON
OFF
Light indicator
(Red)
T
Output
ON
transistor
OFF
Load
(relay)
Operate
Release
(Between blue and black)
34
E3X
E3X
Sensitivity Adjustment
E3X-Tjj
1. Locate the sensor head in the sensing range of the E3X.
2. Set the mode selector to TUNING.
3. Locate the object at the sensing position and press the tuning
button.
Through-beam Model
Reflective Model
Reflective Model
Mark
Light is not
received.
Base
The tuning indicator (red) is lit.
The built-in buzzer beeps once.
4. Move the object and press the tuning button.
Through-beam Model
Reflective Model
Reflective Model
Mark
Light is received..
Base
If tuning is OK:
If tuning is NG:
The tuning indicator turns green.
The built-in buzzer beeps once.
The tuning indicator (red) is still lit.
The built-in buzzer beeps 3 times.
Change the position of the object and the sensing distance that have
been set and repeat from the beginning.
5. Set the mode setting selector to RUN to complete the
sensitivity setting on the E3X.
The tuning indicator (green) is OFF
.
6. Select the logical output required with the operation mode
selector.
Maximum Sensitivity Setting
1. Set the mode setting selector to TUNING.
2. Press the tuning button, at which time the object may or may
not be located at the sensing position.
The tuning indicator (red) is lit.
The built-in buzzer beeps once.
3. Set the mode setting selector to RUN to complete the
maximum sensitivity setting on the E3X. It will take
approximately three seconds for the stable operation
indicator or light reception indicator to be lit. After the
maximum sensitivity setting is completed, the tuning indicator
will turn green and then it will be automatically turned OFF in
approximately three seconds. The maximum sensitivity of the
E3X can be automatically set regardless of the set distance or
light reception.
Note: The sensitivity of the E3X-T11 and E3X-T21 are set to max
-
imum before shipping.
35
E3X
E3X
E3X-H11/-Ajj/-Fjj/-VGjj
Using a sensing object, adjust Sensitivity Adjustor so that the indicators operate as described in the following table:
Sensing method
Through-beam
Sensing
Light
Indicators
Interrupted
Green: Light ON
Red: Light OFF
With sensing object
Incident
Incident
Interrupted
Incident
Without sensing object
Green: Light ON
Red: Light ON
Reflective
Sensing
With sensing object
Green: Light ON
Red: Light ON
Without sensing object
Green: Light ON
Red: Light OFF
Sensing of the
difference in color or
shade
Green: Light ON
Red: Light ON
Color that has a
high reflection ratio
Interrupted
Interrupted
Color that has a
low reflection ratio
Green: Light ON
Red: Light OFF
Retroreflective
Green: Light ON
Red: Light OFF
With sensing
object
Reflector
Incident
Green: Light ON
Red: Light ON
Without sensing
object
Reflector
Note: 1. If the indicators operate as described in the table, the E3X can operate in stable condition within the rated temperature range.
2. Even when the green indicator is OFF, the E3X will operate stably if the operating temperature change since the initial settings is
within +10°C.
36
Light Axis Adjustment with Flashing Function
E3X-Tjj
This function enables the user to adjust with ease the light axis of the through-beam fiber with the light source flashing. All E3X models have this
function.
1. Set the mode setting selector to FLASH.
2. If the axis of the light emission fiber head and that of the
light reception fiber head do not agree with each other
and the amount of light reception becomes 90% of the
peak value or less, the flashing function of the E3X will
work. The E3X retains the peak value when the mode
setting selector is set to FLASH and the axes of the
Mode Setting Selector
fiber heads are adjusted to agree with each other
.
θ
Fiber for light emission
Fiber for light reception
Optical input
The peak of light reception
90% of the peak value
Lit in this range.
Angle of the head (θ)
Flashing
Lit
Flashing
E3X-Ajj/-Fjj/-VGjj
1. Set the mode selector to SET
.
2. Adjust the light axis by moving the fiber with the light
flashing.
Improper Light Axis
Proper Light Axis
Light ON with
no flushing
Flashing
Light axis
adjusted
Mode Selector
3. Set the mode selector to L-ON or D-ON after the light axis
is adjusted.
E3X
E3X
Self-diagnostic Function
With this function, the E3X checks changes in environmental condi
-
Displays
tions (especially a change in the ambient temperature) and
self-diagnoses the resistance against the changes. The result is
shown by the indicators or an output signal.
•
Stable Operation Indicator: Changes in environmental
conditions (changes in the ambient temperature, the operating
voltage, or the volume of dust) are checked and the resistance
against them are self-diagnosed. The result is shown via the
indicator.
Stable Operation Indicator
(Green Indicator)
Light Reception Indicator
(Red Indicator)
•
Light Reception Indicator: The amount of light received is
indicated by this indicator
.
Output
•
The resistance against changes in environmental conditions is
indicated by the indicator and the result is output.
Amount of
light
Operating level x 1.2
1.2
Operating level
1
Operating level x 0.8
0.8
ON
Control output
OFF
(L-ON)
0.3 s min.
0.3 s min.
ON
Self-diagnostic
output*
OFF
Red
Indicator Green
Green
Green
Tip of the fiber connected
to the light source side in
the SET mode
Flashing
light ON
Flashing
*If the self-diagnostic output is ON when the sensing object is
moving at low speed, use the E3X with an ON-delay timer circuit.
Remote Tuning/Remote Bank Function (E3X-T21)
Remote Tuning Function
Basically, the method of remote tuning is same as that of sensitivity adjustment. When the remote tuning function of the E3X is used, the E3X is
tuned with the remote tuning input signal instead of the tuning button which has to be pressed.
1. Set the mode selector to RUN.
2. The following signal conditions must be given as remote
tuning input conditions.
Brown
+V
Black; control output
Orange; self-diagnostis
output
Purple; remote
bank selection
Pink
Blue 0 V
If no remote tuning is done, cut off the purple wire at its
source or connect the pink wire to the positive terminal
of the power supply
.
E3X
E3X
Power supply
ON
OFF
T
T
T
1
Remote tuning input
Sensitivity setting
1
2
H
L
T : 0.5 to 3 s
1
T : 0.5 to 1 s min.
2
Maximum sensitivity
T
2
H
L
T : 5 s min.
2
Remote Bank Function
The remote bank input signal allows the setting of two kinds of sensitivity adjustment values.
Brown
+V
Black; control output
Orange; self-diagnosis
input
Pink
Bank 1: SW = OFF
Bank 2: SW = ON
Purple
Blue 0 V
To set two kinds of sensitivity adjustment values, the
purple and blue wires must be connected with each oth
er and select bank 2 to tune the E3X.
-
Variable Hysteresis Function (E3X-H11)
Sensing of Plate Level Differences
Refer to the following when using the hysteresis adjuster
.
(If sensing is impossible with the hysteresis value set to maximum)
Reflection
of light
Reflection
of light
Reflection
of light
ON
ON
Large hysteresis
differential
ON
Small hysteresis differential
OFF
OFF
OFF
A
B
A
B
A
B
ON
Unstable
Unstable OFF
ON
OFF
Sensing operation is not stable be-
Reduce the sensitivity of the E3X with
the sensitivity adjuster and turn off
zone B.
Reduce the hysteresis value with the
hysteresis adjuster so that zone A will
be ON.
cause zone B is within the hystere
-
sis differential range.
E3X
E3X
Set both the sensitivity
1
2
min max
Hysteresis
adjuster and hysteresis
adjuster to maximum.
SENS
differential
adjuster
min max
Sensitivity
adjuster
Decide the position of
the fiber head and that
of the sensing object in
zone A.
(E)
Locate the head in zone
A and turn the sensitivity
adjuster counterclock-
wise slowly until the
1
2
SENS
min max
stable operation indicator
and light reception indi-
cator are OFF (i.e., posi-
tion E as shown in the il-
lustration).
min max
NO
Locate the head
When the
head is located in zone B,
light reception indicator
is lit.
NO
in zone B and turn the
hysteresis adjuster counterclockwise slowly
and make sure
Set the hysteresis adjust-
er to maximum.
min max
that the light reception
indicator
S
L
S
L
is lit.
YES
YES
(F)
(G)
Locate the head in zone A
and turn the sensitivity ad-
juster clockwise until the
stable operation indicator
and light reception indica-
tor are OFF (i.e., position
F as shown in the illustra-
tion).
S
L
S
L
1
2
SENS
(H)
Set the hysteresis adjust-
er to the point where the
light reception indicator is
lit (i.e., position E as
min max
min max
shown in the illustration).
(E)
Locate the head in zone
A and turn the sensitivity
adjuster counterclock-
wise until the light recep-
tion indicator and stable
operation indicator are
OFF (i.e., position O as
shown in the illustration).
(G)
1
2
SENS
The light reception indicator
min max
NO
is lit when the head is located in zone B and
the light reception indicator is OFF when the
head is located in zone A.
S
L
YES
Sensing is possible.
S
L
B
A
E3X
E3X
External Diagnostic Input Function
With this function, light projection can be stopped when desired.
The operation of the sensor can be checked with this function before
the E3X is placed into actual operation.
E3X-Fjj/-VGjj
No light is emitted from the projection fiber head when self-diagnos
tic input is ON.
-
E3X-Ajj
Light is emitted from the projection fiber head when the self-diag-
nostic input is ON. The sensor, however, will not operate.
NPN Type
Brown (+V)
Pink
(external-
check
Input)
External-diagnostic input Short
(between blue and pink)
Open
Light projection
stops
ON
OFF
LED for light projection
ON
Indicator
ON
OFF
Blue (0 V)
Brown (+V)
Pink
(external-
check
Input)
By short-circuiting the pink and blue cords, light projection can
be stopped (with a short-circuit current of 0.2 mA max.).
Light
OFF
Blue (0 V)
PNP Type
Brown (+V)
ON
External-diagnostic input Short
(between brown and pink) Open
Light projection
stops
ON
OFF
Pink
LED for light projection
Indicator
(external-
check
Input)
ON
OFF
Blue (0 V)
Brown (+V)
By short-circuiting the brown and pink cords, light projection can
be stopped (with a short-circuit current of 0.2 mA max.).
OFF
Light
Pink
(external-
check
Input)
Blue (0 V)
Special Fiber Units
The following special accessories are available (order separately).
Contact your OMRON representative for the details.
Appearance
L
Fiber Units with Special Length of Stainless
Steel Tube
Fiber with different lengths of stainless steel tubes are available.
The length can be ordered in increments of 10 mm between
10 mm min. and 120 mm max.
Applicable Models
E32-TC200F (tube with 0.9 dia.)
E32-TC200B/DC200F (tube with 1.2 dia.)
E32-DC200B (tube with 2.5 dia.)
Tolerance: +1.0 mm if L is 40 mm or less. and +2.0 if L is more
than 40 mm. (Note that standard Fiber Units have a 90-mm or
40-mm long stainless steel tube.)
E3X
E3X
Stainless Steel Tube with a 90° Bend at the Base
Fiber Units with 90° Bend in Stainless Steel
Tube
Length
Applicable Models
E32-TC200B/TC200F/DC200F
ȏ
R
2
Appearance
Stainless Steel Tube with a 90° Bend at the Tip
Length
Bending radius
ȏ
(+1)
1
ȏ
R
1
R 5.0
5.0 mm
7.5 mm
10.0 mm
12.5 mm
10.0 mm
R 7.5
17.5 mm
20.0 mm
22.5 mm
R 10.0
R 12.5
Bending radius
R 5.0
ȏ
(+1)
1
10.0 mm
12.5 mm
15.0 mm
17.5 mm
15.0 mm
The length overall is 120 mm max.
Note: If larger is required, use the E39-F11 Sleeve Bender
R 7.5
17.5 mm
20.0 mm
22.5 mm
ȏ
.
2
R 10.0
R 12.5
The length overall is 120 mm max.
Note: If larger is required, use the E39-F11 Sleeve Bender
ȏ
.
1
Sensing Distance for Tubes with 90
°
Bends
Model
Amplifier
Bending radius
R5.0 R7.5
Standard
R10.0
R12.5
E32-TC200B
E32-TC200F
E32-DC200F
E3X-Tjj
E3X-H11
270 mm
400 mm
180 mm
65 mm
100 mm
50 mm
20 mm
36 mm
18 mm
170 mm 220 mm 240 mm 270 mm
260 mm 330 mm 360 mm 400 mm
E3X-Ajj
E3X-Tjj
E3X-H11
1
10 mm
140 mm 160 mm 180 mm
65 mm 65 mm 65 mm
100 mm 100 mm 100 mm
30 mm
55 mm
30 mm
15 mm
30 mm
10 mm
E3X-Ajj
E3X-Tjj
E3X-H11
50 mm
20 mm
36 mm
18 mm
50 mm
20 mm
36 mm
18 mm
50 mm
20 mm
36 mm
18 mm
E3X-Ajj
Fiber Unit with Longer Fiber
Applicable Models
Appearance
E32-TC200/-DC200
E32-TC200B/-DC200B
E32-TC200E/-DC200E
E32-TC200F/-DC200F
E32-TC200A
ȏ
The length can be ordered in increments of 1 m between
6 m min. and 20 m max.. (2-m and 5-m fiber length types are
standard for E32-TC200, E32-DC200.)
E3X
E3X
Fiber Length vs. Sensing Distance
Through-beam Fiber Unit
Reflective Fiber Unit
(Based on the sensing distance using a fiber length
of 2 m as 100%)
(Based on the sensing distance using a fiber length
of 2 m as 100%)
Fiber length (m)
Fiber length (m)
E3X-Ajj, E32-TC200 (Typical)
E3X-Ajj, E32-DC200 (Typical)
Fiber length (m)
Fiber length (m)
E3X
E3X
Dimensions
Fiber Units
Through-beam
(Sold in Pairs)
E32-T11L
E32-T12L
Two hexagon clamping nuts (T = 2.4)
M2.6 x
0.45
Two toothed washers (for M4)
1.4 dia.
Optical fiber, 2.2 dia.
Sensing head (nickel-
plated brass) M4x0.7
1.4 dia.
2.4 dia. Sensing head (nickel-plated brass) 3 dia. Optical fiber, 2.2 dia.
3
3
11
11
3.2
7
(14)
2,000
(14)
2,000
E32-T21L
E32-T22L
Two hexagon clamping nuts
Two toothed washers
Fiber attachment
(E39-F9)
Fiber attachment
(E39-F9)
25
10
Sensing head, 2 dia. (stainless)
Heat-shrinkable tubing
Sensing head M3 x 0.5
(nickel-plated brass)
Optical fiber, 1 dia.
25
0.9 dia.
1.8 dia.
0.9 dia.
Optical fiber, 1 dia.
10
(2)
17
22
12
2.5
(1.7)
1.8
2,000
11
2,000
5.5
E32-TC200
E32-TC200B
E32-TC200B4
Two hexagon clamping nuts
Two toothed washers
Stainless
tube
(SUS304)
Two hexagon clamping nuts
Two toothed washers
1.0 dia.
1.0 dia.
1.2
M2.6 x 0.45
Sensing head M4 x 0.7 (nickel-plated brass)
Sensing head M4 x 0.7 (nickel-plated brass)
dia
max.
Optical fiber, 2.2 dia.
2.4
Optical fiber, 2.2 dia.
2.4
3.2
7
3
11
90 (40) (see note)
2,000
3.2
7
14
2,000
Note: The value in the parentheses is
for the E32-TC200B4.
Two hexagon clamping nuts
E32-T22
E32-TC200E
Two toothed washers
Fiber attachment
(E39-F9)
25
Sensing head M3 x 0.5
(nickel-plated brass)
Optical fiber, 1 dia.
Heat-shrinkable tubing
Fiber attachment (E39-F9)
25
10
0.5 dia.
Sensing head
SUS303
Optical fiber,
1 dia.
10
0.5 dia.
1.4 dia.
2.5
5.5
1.8
17
22
12
2 dia.
11
2,000
2,000
E32-TC200F
E32-TC200F4
Two hexagon clamping nuts
Two toothed washers
Fiber attachment (E39-F9)
25
Stainless tube
(SUS304)
Sensing head M3 x 0.5
(nickel-plated brass)
Optical fiber, 1 dia.
0.5 dia.
10
0.9 dia. min.
Note: The value in the parentheses is
2.5
for the E32-TC200F4.
1.8
90
(40)
11
2,000
5.5
(see note)
E32-TC200A
E32-T11
Sensing
head (nickel-
plated brass)
M4 x 0.7
Two hexagon clamping nuts
Two toothed washers
Two hexagon clamping nuts
Sixteen,
0.265 dia.
Two toothed washers
Sensing head M3 x 0.5 (nickel-plated brass)
1.0 dia.
2.6 dia.
Protective tube
Optical fiber, 2.2 dia.
M2.6 x
0.45
1.8
3 dia.
Optical fiber, 2.2 dia.
2,000
15
3.3
5.5
(1.5)
2.4
(14)
3.2
7
7
2,000
1 4
E3X
E3X
E32-T21
Sensing head (nickel-plated brass) M3 x 0.5
Two hexagon clamping nuts
Fiber attachment (E39-F9)
25
Four, 0.25 dia.
Two toothed washers
Protective tube
10
Optical fiber, 1 dia.
15
2.5
1.8
11
2,000
(75)
5.5
E32-TC200C
Two hexagon clamping nuts
Two toothed washers
M4x0.7 (nickel-
plated brass)
Sensing head
M2.6 x 0.45
1.0 dia.
22 dia.
Optical fiber,
2.2 dia.
7
2.4
11
90
400
2,000 (when straight)
3
E32-TC200D
E32-TC200D4
Two hexagon clamping nuts
(75)
Stainless
tube
Two toothed washers
Sensing head M4 x
0.7 (nickel-plated
brass)
1.0 dia.
(SUS304)
1.2
dia.
max.
22 dia.
Note: The value in the
parentheses is for
the E32-TC200D4.
Optical fiber,
2.2 dia.
90
2.4
3.2
7
400
11
2,000 (when straight)
Heat-shrinking
90 (40) (see note)
E32-T14L
Sensing head, 3 dia.
(stainless)
Optical fiber,
2.2 dia.
tubing
45°
2.8
1.5
1
1.5
3dia
12
30
35
2,000
Sensing surface
E32-T24
E32-T14
Fiber attachment (E39-F9)
25
Sensing head 1 dia.
SUS304
2 dia.
Protective tube
Optical fiber, 1 dia.
1.4 dia.
10
45%
1
0.5
1.5
15
15
12
35
2,000
E32-T17L
Heat resistive ABS
Sensing head
(ABS) M14 x 1
8.2
Lens unit (PMMA)
4.4 dia.
Two hexagon clamping nuts
10-mm dia.
lens (PMMA)
Optical fiber, 2.2 dia.
7
Optical axis
R3.5
Optical fiber, 2.2 dia.
Two, 3.2 dia.
7
8
10.5
19
5
23
10+0.2
42
2.5
9.2
16
11.2
2,000
10,000
E32-T12F
4-mm
dia. lens
Sensing head, 5 dia.
4 dia.
Optical fiber, 2.2 dia.
Fluoride resin
2,000
20
100
E3X
E3X
E32-M21
Two hexagon clamping nuts
Two toothed washers
Silicone tube
Note: One set of silicone tubes is black while the other
set is gray for easy identification when they are
connected to the light source and receiver
Sensing head
M3 x 0.35
(SUS303)
Plastic fibers, four, 1 dia.
.
Sleeve
13
28
1.8
11
23
2,000
E32-T51
Note: Resistant temperature is 150°C.
Resistant temperature is 130°C
Two hexagon clamping nuts
Two toothed washers
Sensing head M4 x 0.7 (nickel-plated brass)
1.5 dia.
when used continuously
.
2.85 dia.
1
2.4
Optical fiber, 2.2 dia.
2,000
7
15
17
E32-T61
Two hexagon clamping nuts
Two toothed washers
SUS flexible tube
Hexagon clamping screw
4 dia. 5 dia.
1.0 dia.
M2.6 x 0.45
2.8 dia.
Sleeve
Sensing head M4 x 0.7
(SUS303)
(See note)
13
4 dia.
7
3
2.4
5
20
10
2,000
28
A
B
Note: Section A resists 300
The operating temperature of section B must also be within the withstand temperature
range of the Amplifier
°C and section B (which is inserted to the Amplifier) resists 110°C.
.
E3X
E3X
Reflective
E32-D11L
Two hexagon clamping nuts
Two toothed washers
Two, 1.4 dia.
4 dia.
Sensing head (nickel-plated brass) M6 x 0.75
Two optical fiber, 2.2 dia.
5.2
10
3
2.4
20
2,000
E32-D12
2,000 (standard length)
135
3 dia.
15
Two, 1 dia.
Sensing head (stainless)
Heat-shrinkable tubing
Optical fibers, two, 2.2 dia.
E32-D21L
Two fiber attachments (E39-F9)
25
Two hexagon clamping nuts
Two toothed washers
Sensing head M4 x 0.7 (nickel-plated brass)
Optical fiber, two, 1 dia.
10
Two, 0.9 dia.
3
2.4
3.2
7
15
2,000
Two fiber attachments (E39-F9)
E32-D22L
25
10
Sensing head 3 dia.
(nickel-plated brass)
Two, 0.9 dia.
2.7 dia.
Optical fiber, two, 1 dia.
3
15
2,000
E32-DC200
Two hexagon clamping nuts
Two toothed washers
Two, 1.0 dia.
Sensing head M6 x 0.75 (ADC)
4 dia.
3
Optical fiber, 2.2 dia.
2,000
2.4
17
4.8
10
E32-DC200B
E32-DC200B4
Two hexagon clamping nuts
Two toothed washers
Stainless
tube
Two, 1.0 dia.
(SUS304)
Sensing head M6 x 0.75 (fine screw)
2.5 dia.
max.
Note: The value in the
parentheses is for
the E32-DC200B4.
Optical fiber, 2.2 dia.
2,000
2.4
5.2
10
17
90 (40)
(see note)
E32-DC200E
Two fiber attachments (E39-F9)
25
Two hexagon clamping nuts
Two toothed washers
Sensing head M3 x 0.5 (SUS304)
Optical fiber, two, 1 dia.
10
Two, 0.5 dia.
1.8
11
2.5
2,000
5.5
E3X
E3X
E32-DC200F
E32-DC200F4
Two hexagon clamping nuts
Two toothed washers
Sensing head M3 x 0.5
(SUS304)
Fiber attachment (E39-F9)
25
Stainless tube
(SUS304)
1.2 dia. min.
10
Two, 0.5 dia.
Optical fiber, two, 1 dia.
2.5
1.8
90
(40)
11
2,000
5.5
(see note)
Note: The value in the parentheses is for the E32-TC200F4.
E32-D11
Sensing head
(SUS303)
M6 X 0.75
Two hexagon clamping nuts
Sixteen,
0.265 dia.
Two toothed washers (10 teeth)
Protective tube
Optical fiber, two, 2.2 dia.
2.4
15
5.2
10
2,000
17
E32-D21
Fiber attachment (E39-F9)
Sensing head (nickel-plated brass)
25
10
M3 x 0.5
Two hexagon clamping nuts
Two toothed washers
Protective tube
Four, 0.25 dia.
Optical fiber, two, 1 dia.
2.5
1.8
15
11
2,000
(150)
5.5
E32-DC200C
Two hexagon clamping nuts
Two toothed washers
Sensing head M6
x 0.75 (nickel-
Two, 1.0 dia.
plated brass)
22 dia.
Optical fiber,
2.2 x 2 dia.
2.4
5.2
10
17
400
90
2,000 (when straight)
(150)
E32-DC200D
E32-DC200D4
Note: The value in the
parentheses is for
the E32-DC200D4.
Two hexagon clamping nuts
Two toothed washers
Stainless
tube
(SUS304)
Sensing head M6
x 0.75 (SUS304)
Two, 1.0 dia.
2.5 dia.
max.
22 dia.
Optical fiber,
two, 2.2 dia.
2.4
5.2
10
90
17
90
400
2,000 (when straight)
Sleeve
(40) (see note)
E32-DC9G
E32-DC9G4
4
Stainless tube
1.2 dia. max.
8
15
Do not bent the stainless
tube in this range.
7.5
10
6
90
17
13
(40)
(see note)
Note: The value in the parentheses is for the E32-TC200F4.
E32-D33
Fiber attachment (E39-F9)
25
Sensing head
(SUS303)
10
Optical fiber, two, 1 dia.
3 dia.
Heat-shrinkable tubing
0.8 dia.
Two, 0.25 dia.
15
15
12
2,000
35
E3X
E3X
E32-CC200
Sixteen, 0.25 dia.
for light reception
Two hexagon clamping nuts
1.0 dia. for light
emission
Two toothed washers
Sensing head M6 x 0.75
(nickel-plated brass)
Optical fiber, two, 2.2 dia.
2.5 dia.
2.4
23
5.2
10
3
2,000
Note: The fiber for the light source is identified by a white line.
E32-D32
Two fiber attachments (E39-F9)
25
10
Sensing head SUS303
3 dia.
Optical fibers, two, 1 dia.
Light source fiber
(0.5 dia.)
2 dia.
Heat-shrinkable tubing
15
2
12
Receive fiber
(0.25 dia.) x 4
22
2,000
Note: The fiber for the light source is identified by a white line.
E32-D32L
2,000 (standard length)
15
1,570
400
15
Light source (1 dia.)
Receive (0.265 dia.) x 16
Sensing head, 3 dia. (stainless)
Optical fibers, two, 2.2 dia.
Branching box, 6 dia.
(heat-resistive ABS
black resin)
Note: The fiber for the light source is identified by a yellow dotted line.
E32-D14L
Sensing head
(stainless)
Optical fiber, two, 2.2 dia.
Heat-shrinkable tubing
45°
5.7
1.5
1
6 dia.
2
30
35
12
2,000
Light baffle
Sensing surface
Two fiber attachments (E39-F9)
25
E32-D24
Sensing head (SUS304)
10
Optical fibers, two, 1 dia.
Heat-shrinkable tubing
3 dia.
2 dia.
45%
1
0.5
1.5
15
15
12
2,000
35
Light baffle Sensing surface
E32-D12F
Sensing head, 6 dia.
Optical fiber, two, 2.2 dia.
Fluoride resin
2,000
5 dia.
16
100
E3X
E3X
Two hexagon clamping nuts
Two toothed washers
E32-D51
Optical fiber, 2.2 dia.
Two, 1.5 dia.
4.9
Sensing head,M6 x 0.75*
*nickel-plated brass
Note: Resistant temperature is 150°C.
Resistant temperature is 130°C
2.4
when used continuously
.
3.1
10
13
3
2,000
17
E32-D61
Two hexagon clamping nuts
Two toothed washers
Sensing head (SUS303)
M3 x 0.75
SUS304
Sleeve
SUS flexible tube
Hexagon clamping screw
1.4 dia.
M4 x 0.7
5 dia.
3.5 dia.
8
15
(See note)
13
10
6.4
5
6.5
3
2
2.4
3
5
16.5
2,000
20
B
A
Note: Section A resists 300
°C and section B (which is inserted to the Amplifier) resists 110°C. The operat-
ing temperature of section B must also be within the withstand temperature range of the Amplifier
.
E32-D73
Two hexagon clamping nuts
Two toothed washers
SUS303
Hexagon clamping screw
5 dia.
Sleeve
Sensing head
1.25 dia.
M4 x 0.7 (SUS303)
4 dia.
SUS flexible tube
2.8 dia.
1.0 dia.
2.5 dia.
1.65 dia.
8
15
7
2.4
(See note)
13
5
6.5
5
5
6.4
60
20
10
2,000
16.5
A
B
C
Note: Section A resists 400
resists
range of the Amplifier
°
C, section B resists 300°C, and section C (which is inserted to the Amplifier)
1
10°C. The operating temperature of section C must also be within the withstand temperature
.
E32-R21
Two fiber attachments (E39-F9)
25
Two hexagon clamping nuts
Two washers
Lens
(PMMA)
Sensing head
5 dia.
Silicone tube
10
M6 x 0.75
Optical fibers, two, 1 dia.
2.2
10
3
2.8
11
14
17.8
2,000
27.8
Nameplate
27
E32-R16
15
7
13
1.5
3.2
3.2
1.5
16
10
7.2
4
(6)
8
15.2
21.5
Optical fiber, two, 2.2 dia.
Standard length: 2 m
21
22.5
Lens (PMMA)
16+0.2
17
Two, M3 screws (attachment)
1
Mounting bracket (attachment)
E3X
E3X
20
10
E32-L25
E32-L25A
5
4
4.8
6.5
6.5
20
10
5
20
4
4.8
6.5
6.5
White line
Optical fiber, two, 2.2 dia.
20
Two, 3.2 dia.,
6 dia. spot facing
2,000
White line
Two, 3.2 dia.,
6 dia. spot facing
2,000
Sensing head (ABS)
Optical fiber,
two, 2.2 dia.
Note: The fiber for the light source is
identified by a white line.
E32-L25L
18
Two fiber attachment
(E39-F9)
4
25
6
Two, 1 dia. optical fibers
10
16
6.5
Sensing head
(PC)
Two, 3.2 dia, 6 dia.
2,000
counter sinking
E32-L24L
4
3.6
18
Side view prism (PC)
3.3
Two fiber attachment
(E39-F9)
1.5
4
3.3
6
25
Optical
axis
20
Two, 1 dia. optical fibers
10
6.5
Sensing head
(PC)
Two, 3.2 dia, 6 dia.
2,000
counter sinking
E3X
E3X
Fine Through-beam
E32-T22S
E32-T24S
0.4
1.8
Sensing head
(nickel-plate brass)
Optical fiber 2.2 dia.
3.5 dia.
11 3.2
17.6
Mounting bracket (attachment)
2,000
3.2
10
3
20.5
2 dia.
2
Sensing surface
E32-T84S
2,000 (standard length)
(see note)
Sleeve
4 dia.
2.9 dia. flexible
tube (stainless)
4 dia.
5 dia.
3.5 dia.
Sensing head (stainless)
3 dia.
Lens (2 dia.)
Note: Section A resists 200
°C and section B (which is inserted to the Amplifier) resists 110°C. The operating
temperature of section B must also be within the withstand temperature range of the Amplifier
.
Slot Fiber Units
E32-G14
Sensing head (ABS)
2,000
36.3
25.2
20
Mounting Holes
9.2
R1.6 R1.6
Two, M3
R3.5
Optical axis
24 10
9.0
3.2
9.4
Lens
(PMMA)
Optical fiber, 2.2 dia.
4
1.6
1.6
23.5
9.4
7.4
7.0
E3X
E3X
Liquid Level Fiber Units
E32-D82F1/E32-D82F2
(Liquid Contact Model)
9 dia. fiber connector
(nickel-plate brass)
6 dia. sensing head (Teflon)
Two, 2.2 dia. optical fiber
(see note 2)
To Amplifier
Bending-prohibited length:
150 (350) (see note 1)
Note: 1. The value in the parentheses is for the E32-D82F2.
2. Since the 2-m optical fiber on the Amplifier side is made of
plastic, the fiber is trimmable.
E32-L25T (Pipe
Mounting Model)
Optical axis
Two, 3.2 dia.
lens (PC)
Two, fiber attachment
Two, 1 dia. optical fiber
Mounting hole
Sensing head
(PC)
2,000 (standard length)
E3X
E3X
20
E32-T16
2 (R)
10.2
4
3.2
0.5-mm Wide Silt Seal
(Sold in Pairs)
20
4
6
20
0.5
4
Sensing
head
(ABS)
2 (R)
2 (R)
1.2
4.5
11
15.5
8.85
Two, M3
5.5
2.3
8.4
3
23
15
3.2
Black
25
20
27
1-mm Wide Silt Seal
(Sold in Pairs)
Lens
(2 x 10)
(PMMA)
6
58
1
6 dia.
43.2
4
Two, 3.2 dia.
2,000
Mounting bracket
E39-L4
15
23
Black
33
Fiber 2.2 dia.
E32-T16P
Two, 3.2 dia., 6 dia counter sinking
14.5
10.7
4
0.5-mm-wide Slit Seal
(Sold in Pairs)
E32-T16P with E39-L94
Mounting
35
3.4
20
2
0.5
4.8
4
19
27
20
Sensing head
(2 x 11)
(PMMA)
13.4
26.4
Two, M3
20
4
4
Sensing head
(heat-resistive ABS)
Black
12.2
3.2
1-mm-wide Slit Seal
(Sold in Pairs)
2,000
3.4
Sensing
head
19
4
1
2.2-dia. optical fiber
52
13.4
26.4
43.2
23.2
Black
E39-L94 Mounting Bracket
2.2-dia.
fiber
E3X
E3X
Amplifier
E3X-T11
E3X-T21
Light reception indicator
17.8
9
Stable operation
indicator
Tuning indicator
59
12
6.5
4
1.2
4.2
11
Two, 2.4
32
25
8
0.4
12.5
3.9
8.4
Cord: 2-m polyvinyl chloride-covered cord
(4-mm dia., 3 cores*)
Weight: Approx. 100 g
22.5
13
16
35.5
6
6
3.2 dia.
*The cords for the E3X-T21 model has 6 cores.
Mounting bracket (removable)
2
3.4
22.5
16
E3X-H11
Light reception indicator
15.8
E3X-Ajj
E3X-Fjj
E3X-VGjj
9
Stable operation indicator
59
4
Two, 2.4 dia.
30
8
25
12.5
8.4
3.9
6
6
22.5
13
16
35.5
Mounting bracket (removable)
Cord: 2-m polyvinyl chloride-covered c
(4-mm dia., 5 cores*)
Weight: Approx. 100 g
*The cords for the E3X-A11, E3X-A41, a
E3X-VG11 models have 3 cores.
3.2 dia.
3.4
22.5
2
16
E3X
E3X
Reflector
Reflector (Small)
E39-R3
Reflector
E39-R1
11
Adhesive tape
40.3
34
Two, 3.5 dia.
7.5
7
20
Note:
0.2
52
59.9
25.4 34 38
34.8
8
2.7
1.6
19.3
1.2
Two, M3
2.6
Attachments
E39-F1
Lens Kit
E39-F2
Side-view Attachment
E39-F3
Convergent Beam Conversion Kit
M3 toothed
Two, 4 dia. washers
M2.6
Effective depth: 3.2
Spot facing depth: 0.9
M2.6 x 0.45
Effective depth: 3.8
Spot facing depth: 0.9
Two, M3 x 3 Slotted
head machine screw
T
wo, 3.2+00.2 dia.
2.8 dia.
4 dia.
4 dia.
18
6.4
5.7
9.2
12
8.9
6.4
6.5
8+0.2
20.7
3
M3 x 6 Angle
fixing screw
Note: One set includes two units.
3.6
8.5
E39-F5
E39-F3A
Side-view Diffuse Reflective Conversion Kit
(for the E32-TC200A)
Reflective Lens Unit (for the E32-D32)
Two, M3
Fiber unit mounting
holes (E32-TC200A)
Sensing hole
Two, 3.2 dia.
M2 x 2
4 dia.
Two, 3.2 dia.
Mounting hole
12.2
6 dia.
2.1
3
4
Lens (3.7 dia.)
13
23
13
2.1 dia.
2.6
4
5
10.5+0.1
18
E3X
E3X
Protective Spiral Tubes
E39-F32A, E39-F32A5
E39-F32B, E39-F32B5
M3 x 0.5 depth: 4
6 dia.
Head connector
End cap
12
3 dia.
4.6 dia.
12
L
Note: 1. L is as follows:
E39-F32A and E39-F32B: 1,000
E39-F32A5, E39-F32B5: 500
2. A pair of E39-F32A(5)’s is sold as E39-F32B(5).
E39-F32C, E39-F32C5
M4 x 0.7 depth: 4
7 dia.
Head connector
End cap
5.6 dia.
4 dia.
12
12
L
Note: L is as follows:
E39-F32C: 1,000
E39-F32C5: 500
E39-F32D, E39-F32D5
Head connector
End cap
M6 x 0.75 depth: 4
8.5 dia.
7 dia.
5 dia.
12
12
L
Note: L is as follows:
E39-F32D: 1,000
E39-F32D5: 500
Accessories
E39-F4 Fiber Cutter
Holes for standard fiber
Holes for thin fiber
E39-F9 Attachment for Thin Fiber
E39-F10 Fiber Connector
Splice
26
Retention clip
3.8 dia.
Insertion mark
1.1 dia.
Retention clip
Fiber
(2.4 dia.)
2.2 dia.
3 dia.
12.8
10
11.7
3.6 dia.
25
Note: One set includes two Units.
E3X
E3X
E39-G3 Manual Sensitivity Adjustment Knob
Note: Cannot be used with the E3X-Tjj.
10 dia.
E39-G4 Protective Cover
Note: Cannot be used with the E3X-Tjj.
E3X
E3X
Installation
Connections
Connection with S3D2 Sensor Controller
Connection with S3D8 Sensor Controller
Blue
Black
Black
Blue 0 V
Brown
Brown
+12 V
0 V
IN1
+12 V
7
8
9
10 11 12
IN1
IN2
NORM
4
INV
6
5
2
1
3
Note:
A
maximum of two E3X Optical Fiber Photoelectric
Note:
A
maximum of eight E3X Optical Fiber Photoelectric Sen
-
Sensors can be connected.
sors can be connected.
Power supply voltage
Output
Relay
Functions
NPN input
PNP input
S3D2-AKB-US
S3D2-CKB-US
---
100 to 240 VAC
AND, OR
S3D2-AK-US
S3D2-CK-US
S3D2-BK-US
S3D2-CC-US
AND, OR, and timer
Flip-flop
Transistor
AND, OR, and timer
S3D2-CCB-US
E3X
E3X
Precautions
Fiber Units
Tightening Force
Fiber Connection and Disconnection
The E3X Amplifier has a push lock. Connect or disconnect the fibers
to or from the E3X Amplifier using the following procedures:
The tightening force applied to the Fiber Unit should be as follows:
Screw-mounting Model
1. Connection
Spring mounting clip
Toothed washers
Nuts
(attachment)
Insert the fibers into the E3X Amplifier and press the push lock until
the Amplifier clicks to lock the fibers. The fibers will have insertion
marks when they are cut with the E39-F4 (Fiber Cutter). The portion
from the tips to the insertion mark should be inserted to the E3X.
Column Model
Retaining screw
(M 3 max.)
Clamping torque
3 kgf cm max.
S
2. Disconnection
Be sure to press the push lock again to unlock before pulling out the
fiber, otherwise the fiber may be deteriorated.
Fiber Insertion
If the portion from the tip to the insertion mark of the fibers are not
inserted into the Amplifier Unit, the sensing distance will be re-
duced.
Fiber units
M3/M4 screw
M6 screw
Clamping torque
cm max. (0.78 N m)
cm max. (0.98 N m)
2.2-mm dia. Fiber
8 kgf
S
S
Amplifier
10 kgf
S
S
Insertion mark
2-mm dia. column 3 kgf
3-mm dia. column 3 kgf
S
S
cm max. (0.29 N
cm max. (0.29 N
S
S
m)
m)
E32-D14L
E32-T12F
E32-D12F
E32-T16
10 kgf S cm max. (0.98 N S m)
Fiber unit
12.6 mm
8 kgf
8 kgf
5 kgf
6 kgf
S
S
S
S
cm max. (0.78 N
cm max. (0.78 N
cm max. (0.49 N
cm max. (0.59 N
S
S
S
S
m)
m)
m)
m)
Thin Fiber with the E39-F4 Attachment
The portion from the
Amplifier
E32-R21
E32-M21
tips to the insertion
mark should be in-
serted into the E3X.
Up to 5 mm to the tip: 5 kgf S cm max.
(0.49 N m)
Up to 5 mm from the tip: 8 kgf S cm max.
(0.78 N m)
S
S
Fiber unit
12.6 mm
E32-L25A
8 kgf cm max. (0.78 N S m)
S
Use a proper-sized wrench.
Fiber with Fixed Length
The portion from the
tips to the insertion
mark should be in-
serted into the E3X.
Amplifier
12.6 mm
E3X
E3X
Cutting Fiber
Insert a fiber into the Fiber Cutter and determine the length of the
fiber to be cut.
Connection
Do not pull or press the Fiber Units. The Fiber Units have a with-
stand force of 1 kg or 3 kg (pay utmost attention because the fibers
are thin).
Press down the Fiber Cutter in a single stroke to cut the fiber
.
Do not bend the Fiber Units beyond the permissible bending radius.
Do not bend the edge of the Fiber Units.
When the fiber is cut, an insertion mark is inscribed on the fiber
.
For a 2.2-mm dia. standard fiber only
.
40 mm max.
Insertion mark
12.6
Correct
it
2.2-dia.
Insert a fiber into the Fiber Cutter in the direction indicated by the
arrow (refer to the following figure).
Incorrect
2
Do not apply excess force on the Fiber Units.
1
unit
The cutting holes cannot be used twice. If the same hole is used
twice, the cutting face of the fiber will be rough and the sensing dis
tance will be reduced. Always use an unused hole.
-
Correct
Metal holder
Use either one of the two holes on the right (refer to the following
figure) to cut a thin fiber as follows:
Incorrect
1. An attachment is temporarily fitted to a thin fiber before
shipment.
The Fiber Head could be broken by excessive vibration. To prevent
this, the following is effective:
Temporarily fitted
b vibrations
2. Secure the attachment after adjusting the position of it
-turn loop can
in the direction indicated by the arrow
.
3. Insert the fiber into the E39-F4 to cut.
Tape
Cutter E39-F4
Two holes for
thin fiber
Three holes for
standard fiber
(2.2 mm dia.)
Note: Insert the fiber in the direction indicated by the arrow
.
E3X
E3X
Bending Radius
Handling
E39-F11 Sleeve Bender
E32-D51/-T51 Heat-resisting Fiber
The bending radius of the stainless tube should be as large as pos
-
The bending radius of the fibers should be 35 mm min.
sible. The smaller the bending radius becomes, the shorter the
sensing distance will be.
Connecting fibers via the E39-F10 Fiber Connector is not possible.
The withstand temperature of the Heat-Resisting Fibers is 150°C
max. In continuous operation, the ambient temperature should be
130°C max.
Insert the tip of the stainless sleeve to the Sleeve Bender and bend
the stainless sleeve slowly along the curve of the Sleeve Bender (re
-
fer to the figure).
E32-T14/-T51
1.2 dia.
max.
1.2 dia.
max.
If the sensor is ON because some object in front of the lenses re-
flects light, attach the black seals (sold together) to the lenses.
1.3 dia.
min.
R 10
R 5
E32-T14/-G14
R 12.5
R 7.5
Seal
on mark
E32-L25 (A) Wafer Sensor
Stainless tube
Insert the fiber with a white line into the light projection side of the
Amplifier.
The tightening force of the sensor head is 8 kgf S cm (0.75 N S m).
Avoid places where water could be sprayed onto the E32-L25(A).
E32-T16 Slit Seal (Attachment)
Peel the E32-T16 Slit Seal off the ground paper and affix the Slit
Seal to the sensing face of the sensor so that the corners of the Slit
Seal fit in with the corners of the sensing face. To sense an object at
o
10
90 max.
a
distance of 30 cm max., a 0.5-mm wide Slit Seal must be used.
10
E32-T16 Sensing Head
Do not bend here.
Attachment slit
Others
Amplifier Units
Mounting
When power is off:
The moment power is turned off, the E3X could output a pulse signal
which could affect the operation of the devices connected to it. This
Mounting
will happen more often if power is supplied to the E3X from an exter
nal power supply, thus affecting the connected timer and counter.
Use a built-in power supply as much as possible to avoid this.
-
1. Mount the front part on the mounting bracket (sold together)
or a DIN rail.
2. Press the back part onto the mounting bracket or the DIN rail.
If power is supplied to a photoelectric sensor through a cord that is
wired together with other power lines in the same duct, the cord will
be influenced by the power lines and malfunctioning of the photo-
electric sensor or damage could result. Wire the cord separately or
3
use a sealed cord to supply power to the photoelectric sensor
.
2
In the case of the cord is extended, use a wire with 0.3 mm max..
The total length of the cord should be 100 m max.
2
1
DIN rail
line
Dismounting
By pulling back the lock (yellow) on the bottom with a flat blade
screwdriver, the Amplifier can be dismounted with ease.
In the case of side mounting, attach the mounting bracket on the
Amplifier first, and secure the Amplifier with M3 screws and wash
ers. The diameter of the washers should be 6 mm max.
-
Power supply:
If a standard switching regulator is used as a power supply, the
frame ground (FG) terminal and the ground (G) terminal must be
grounded, or otherwise the E3X can malfunction, influenced by the
switching noise of the power supply
.
The supplied voltage must be within the rated voltage range. Unreg
-
ulated full- or half-wave rectifiers must not be used as power sup-
plies.
Do not use a hammer to hit the Amplifier when mounting or the Am
plifier will loose watertightness.
-
Washers (6 dia. max.)
E3X
E3X
Attachment Units
E39-F3A Reflective Unit Lens
When the E39-F3A is attached to the fiber, the E3X can sense the
light reflected from the interior of the E39-F3A. If this happens, ad
just the sensitivity of the E3X Amplifier with Sensitivity Adjustor
Applications
E39-F10 Fiber Connector
-
Use the following procedure (refer to the figure) to connect fibers via
.
the Fiber Connector
.
Place a sensing object or white paper at the sensing distance set
and adjust the insertion length of the Fiber Unit to the E39-F3A so
that the light spot is as small as possible. Then fix the position of the
Fiber Unit with the hexagonal wrench (attachment)
Splice
Retention Unit
Retention Unit
Tighten
A
Loosen
Lens
Each fiber should be as close as possible before they are con-
nected.
B
Insertion
Sensing distance will be reduced by approximately 25% when fibers
are connected.
Fiber Unit (E32-D32)
Only fibers with 2.2 mm dia. can be connected.
A: The focus is farther than the E39-F3A.
B: The focus is closer than the E39-F3A
Protective Spiral Tube
Insert a fiber to the Protective Spiral Tube from the head connector
side (screwed) of the tube.
E39-G3 Sensitivity Adjustor
1. Remove the cover of the E3X.
2. Attach the E39-G3 (refer to the figure).
Fiber Unit
Protective spiral
tube
Cover
Knob
Push the fiber into the Protective Spiral Tube. The tube should be
straight so that the fiber is not twisted when inserted. Then turn the
end cap of the spiral tube.
Fiber Unit
Protective spiral
tube
3. After the cover is attached to the case, turn the knob of the
E39-F3A clockwise or counterclockwise once. To confirm
that the knob has been set properly, turn the knob clockwise
or counterclockwise until you hear a click (8 turns max. are
necessary).
Secure the Protective Spiral Tube on a suitable place with the at-
tached nut.
Note: E3X looses watertightness if E39-G3 is attached (the en-
Mounting panel
closure rating will be IP50).
Hexagon clamping nut
Fiber Unit
Protective spiral
tube
Toothed washer
Use the attached saddle to secure the end cap of the Protective Spi
-
ral Tube. To secure the Protective Spiral Tube at a position other
than the end cap, apply tape to the tube so that the portion becomes
thicker in diameter
.
Saddle
Tube
End cap
E3X
E3X
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. E215-E1-3
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Systems Components Division H.Q.
28F Crystal Tower Bldg.
1-2-27, Shiromi, Chuo-ku,
Osaka 540 Japan
Phone: 06-949-6012 Fax: 06-949-6021
Printed in Japan
0196-2M (0691)
a
相关型号:
E32-TC200BR
These Fibers Units can be used in a variety of applications, such as detecting the presence of workpieces and positioning.