E2E-X2D2-U2M [OMRON]

Standard Proximity Sensor; 标准接近传感器
E2E-X2D2-U2M
型号: E2E-X2D2-U2M
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Standard Proximity Sensor
标准接近传感器

传感器 接近传感器
文件: 总36页 (文件大小:2865K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Standard Proximity Sensor  
E2E  
CSM_E2E_DS_E_8_1  
Your Search for Proximity Sensors  
Starts with the World-leading  
Performance and Quality of the E2E  
• Standard Sensors for detecting ferrous metals.  
• Wide array of variations. Ideal for a variety of applications.  
• Models with different frequencies are also available to prevent  
mutual interference.  
• Superior environment resistance with standard cable made of oil-  
resistant PVC and sensing surface made of material that resists  
cutting oil.  
• Useful to help prevent disconnection.  
Cable protector provided as a standard feature.  
*1, *2  
*1: No AC/DC 2-wire models or AC 2-wire M8 models are compliant.  
*2: Attach three ferrite clamps to the cable of the E2E-X3@@ and  
E2E-X8MD@. (Refer to information on TDK catalog number  
ZCAT2035-0930A.)  
Be sure to read Safety Precautions on  
page 27.  
Features  
2-Wire Models  
Pre-wired Models with Oil-resistant Reinforced PUR Cables Added  
to the Lineup and Easy Differentiation with Orange Head  
Cable Flexibiliittyy at  
Cable Flexibility  
Low Temperatures  
Oil Resistance  
Differentiation from standard  
models: Orange Head  
Oil Resistance (Insulation service life):  
twice or three times  
that of oil-resistant vinyl chloride  
Cable Flexibility:  
approximately twice  
that of cinyl chloride cables  
More Flexibility at 40°C  
Lineup includes models with Smartclick pre-wired connectors for fast connection.  
XS5 Smartclick connectors used to  
enable checking connector mating  
Jacket: Polyester elastomer  
Insert all  
the way.  
1/8 turn  
Insulation: Oil-resistant grade PUR (polyurethane)  
1
E2E  
Lineup includes models with self-diagnostic output to provide notification of failures and  
unstable detection conditions, such as coil burnout.  
Contributes to preventive maintenance to keep the line from stopping.  
Reduced wiring, fewer resources, and low power consumption contribute to  
environmentalism.  
Wiring work and amount of copper wire used reduced to two thirds of that required for 3-wire models.  
Current consumption drastically reduced to less than 10% (when a DC 2-wire model is compared with a DC 3-wire model).  
3-Wire Models  
Lineup includes models with small diameter (3 dia., 4 dia., 5.4 dia., M5)  
All small-diameter models use sealed construction. Operation is stable even when the Sensor is mounted in a small space or embedded in metal.  
Bright indicators enable easily checking the installation condition.  
Wide range of ambient operating temperatures: 40°C to 85°C (M8 to M30 models)  
Wide range of ambient operating temperatures also for small-diameter models: 25°C to 70°C  
Suitable for low-temperature and high-temperature applications, which are troublesome for photoelectric sensors.  
Lineup includes models with flexible cable (4-dia. to M30 models)  
Reduced risk of disconnection in applications with moving parts.  
2
E2E  
Models Listed by E2E Type  
: Standard Models, : Different frequency, @: Self-diagnosis, : Different frequency and self-diagnosis,  
---: Not listed  
2-Wire Models  
Oil-resistant  
reinforced  
PUR cable  
Standard cable and flexible cable  
(cable material: oil-resistant PVC)/Connector models  
Page  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
M8  
2 m  
Yes  
Yes  
No  
Refer to  
page 7.  
●▲@■  
●▲@  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
M12  
3 mm  
Refer to  
Models  
with Self-  
diagnostic  
Output on  
page 8.  
---  
---  
---  
---  
---  
---  
---  
---  
---  
●▲@■  
---  
●▲@  
Shield-  
ed  
Yes  
No  
---  
---  
---  
---  
---  
---  
M18  
7 mm  
Refer to  
Models  
---  
---  
---  
---  
---  
---  
---  
---  
with con-  
ventional  
connector  
pin assign-  
ments on  
page 9.  
---  
---  
●▲@■  
●▲@  
Yes  
No  
DC  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
M30  
10 mm  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
Refer to  
page 8.  
M8  
4 mm  
---  
---  
Refer to  
Models  
with Self-  
diagnostic  
Output or  
Models  
with con-  
ventional  
connector  
pin assign-  
ments on  
page 9.  
●▲@■  
●▲@  
---  
---  
---  
---  
---  
M12  
8 mm  
---  
---  
---  
Un-  
shield-  
ed  
Yes  
●▲@■  
●▲@  
M18  
14 mm  
---  
---  
---  
●▲@■  
●▲@  
M30  
20 mm  
Refer  
to page  
29.  
NC  
---  
---  
---  
---  
---  
---  
---  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
M8  
1.5 mm  
●▲  
M12  
2 mm  
---  
Shield-  
ed  
●▲  
M18  
5 mm  
---  
●▲  
M30  
10 mm  
---  
---  
---  
AC  
---  
---  
---  
M8  
2 mm  
Refer  
to page  
10.  
●▲  
M12  
5 mm  
Un-  
shield-  
ed  
---  
---  
---  
---  
---  
---  
---  
●▲  
M18  
10 mm  
●▲  
M30  
18 mm  
---  
---  
---  
---  
---  
---  
M12  
2 mm  
---  
Shield-  
ed  
M18  
5 mm  
AC/DC  
---  
---  
---  
---  
---  
M30  
10 mm  
---  
3
E2E  
: Standard Models, : Different frequency, ---: Not listed  
3-Wire Models  
Oil-resistant  
reinforced  
PUR cable  
Standard cable and flexible cable  
(cable material: oil-resistant PVC)/Connector models  
Page  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
3 dia.  
0.6 mm  
4 dia.  
0.8 mm  
---  
---  
M5  
1 mm  
---  
---  
5.4 dia.  
1 mm  
Refer  
to page  
11.  
---  
---  
Shield-  
ed  
M8  
1.5mm  
---  
---  
●▲  
---  
---  
---  
---  
---  
---  
M12  
2 mm  
---  
---  
DC  
Yes  
NPN  
●▲  
M18  
5 mm  
---  
---  
●▲  
M30  
10 mm  
---  
---  
---  
---  
M8  
2 mm  
---  
●▲  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
M12  
5 mm  
Refer  
topage  
12.  
Un-  
shield-  
ed  
---  
---  
●▲  
M18  
10 mm  
---  
---  
●▲  
M30  
18 mm  
Refer  
to page  
29.  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
3 dia.  
0.6 mm  
4 dia.  
0.8 mm  
---  
M5  
1 mm  
---  
---  
---  
5.4 dia.  
1 mm  
Refer  
to page  
11.  
Shield-  
ed  
M8  
1.5mm  
---  
---  
●▲  
---  
---  
---  
---  
---  
---  
M12  
2 mm  
---  
---  
DC  
PNP  
Yes  
●▲  
M18  
5 mm  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
M30  
10 mm  
---  
M8  
2 mm  
---  
---  
---  
---  
---  
---  
---  
M12  
5 mm  
Refer  
topage  
12.  
Un-  
shield-  
ed  
---  
M18  
10 mm  
---  
M30  
18 mm  
---  
4
E2E  
E2E Guide to Selection by Purpose  
40 to 85°C  
AC 2-wire: M12 to M30,  
DC 3-wire: M8 to M30  
Wide operating  
Environment  
temperature range  
25 to 70°C  
Models not listed above.  
Resists the influence of surrounding metal  
Shielded Models  
DC 2-Wire Models  
E2E-X@D@  
Reducing stocked  
NPN/PNP output  
Maintenance  
models  
AC/DC 2-Wire Models  
E2E-X@T1  
AC/DC  
Smartclick Pre-wired  
Connector Models  
E2E-X@D@-M1TGJ-(U)  
Easy replacement  
Pre-wired Connector  
Models  
E2E-X@D1-M1(G)J-(T)  
Connector Models  
E2E-X@D@-M1(G)  
E2E-X@E@-M1  
E2E-X@Y@-M1  
Reinforced  
Standard  
Models with Oil-resistor  
reinforced PUR cable  
E2E-X@D@-U  
Higher oil resistance  
Reducing troubles  
Models with Oil-resistant PVC  
cable  
Mounting to moving  
Robotics Cable Models  
E2E-X@D1-R  
parts  
Robotics cable  
E2E-X@E1-R  
Mutual interference  
prevention  
Models with a Different  
Frequency (NO Models  
only)  
E2E-X@@15  
Load short-circuit  
DC 2-Wire Models  
E2E-X@D@  
Miswiring measures  
protection  
DC 3-Wire Models  
E2E-X@E@  
DC 2-Wire  
No-polarity Models  
E2E-X@D1-M1J-T  
No polarity  
Early discovery  
of problems  
Diagnostic Models  
E2E-X@D1S  
Note: Refer to Models Not Listed in this Catalog for Long Body Models, Transmission Couplers, and Power Couplers.  
5
E2E  
E2E Model Number Legend  
A B C D E F G - H I - J - K - L  
M
E2E-  
No.  
Classification  
Code  
Meaning  
Remarks  
C
X
Cylindrical (not threaded)  
Cylindrical (threaded)  
A
B
C
Appearance  
Number  
Sensing distance (Unit: mm)  
Example:  
R6: 0.6 mm  
1R5: 1.5 mm  
Sensing distance  
Shielding  
R
Indication of decimal point  
Blank  
Shielded Models  
M
Unshielded Models  
B
DC 3-wire PNP open-collector output  
DC 3-wire NPN open-collector output  
DC 2-wire polarity/no polarity  
DC 3-wire NPN collector load built-in output  
DC 3-wire PNP collector load built-in output  
AC/DC 2-wire  
C
D
Whether D models have  
polarity is defined by num-  
ber J.  
Power supply and output  
specifications  
D
E
F
T
Y
AC 2-wire  
1
2
Normally open (NO)  
Form of output switching el-  
ement  
E
F
G
Normally closed (NC)  
Standard frequency  
Blank  
5
Used to prevent mutual in-  
terference.  
Oscillation frequency type  
Self-diagnosis  
Different frequency  
Blank  
5
No  
Yes  
Blank  
M1  
Pre-wired  
H
Connection method  
M12-size metal connector  
M8-size metal connector  
M3  
Connector Models  
DC 3-wire and AC 2-wire, DC 2-wire with self-diagnosis output,  
DC 2-wire with old pin arrangement (polarity)  
Blank  
G
Connector Models  
DC 2-wire with IEC pin arrangement (polarity)  
Pre-wired Connector Models  
DC 3-wire and AC 2-wire, DC 2-wire with IEC pin arrangement  
(polarity), DC 3-wire and AC 2-wire, DC 2-wire with self-diagno-  
sis output, DC 2-wire with old pin arrangement (polarity)  
J
I
Connector specifications  
Pre-wired Connector Models  
DC 2-wire with IEC pin arrangement (polarity)  
GJ  
TJ  
Pre-wired Smartclick Connector Models  
DC 2-wire with IEC pin arrangement (no polarity)  
Pre-wired Smartclick Connector Models  
DC 2-wire with IEC pin arrangement (polarity)  
TGJ  
Blank  
T
Polarity  
J
K
DC 2-wire polarity  
No polarity  
Blank  
R
Standard PVC cable (oil resistant)  
Flexible PVC cable (oil resistant)  
Polyurethane cable (oil resistant and reinforced)  
Cable specifications  
U
This is blank if the cable  
specification in number K  
is R or U.  
New model (Applies only to DC 2-wire pre-wired and shielded  
models.)  
L
M
New model  
N
Example:  
2M  
0.3M  
Cable length (Unit: m) (Applicable to Pre-wired Models and Pre-  
wired Connector Models.)  
Cable length  
Letter M  
Note: The purpose of this model number legend is to provide understanding of the meaning of specifications from the model number.  
Models are not available for all combinations of code numbers.  
Ask your OMRON representative if you require a customized model.  
6
E2E  
Ordering Information  
2-Wire Models  
Shielded DC 2-wire Models with No Self-diagnostic Output [Refer to Dimensions on page 29.]  
Opera-  
Applicable  
connector  
code *4  
Appear-  
ance  
Connection  
method  
Cable  
specifications  
Polar-  
ity  
Pin  
arrangement  
Sensing distance  
tion  
Model  
mode  
NO  
NC  
NO  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
1: +V, 4: 0 V  
1: +V, 2: 0 V  
1: +V, 4: 0 V  
E2E-X2D1-M1TGJ-U 0.3M  
E2E-X2D2-M1TGJ-U 0.3M  
E2E-X2D1-M1TGJ 0.3M  
E2E-X2D1-U 2M  
PUR (increased  
oil-resistant)  
M12 Pre-wired Smart-  
click Connector Mod-  
els (0.3m)  
H
G
PVC (oil-resistant)  
PUR (increased  
oil-resistant)  
E2E-X2D2-U 2M  
Pre-wired Models  
(2 m)  
---  
---  
M8  
Yes  
E2E-X2D1-N 2M *2*3  
E2E-X2D2-N 2M *3  
E2E-X2D1-M1G  
2 mm  
PVC (oil-resistant)  
1: +V, 4: 0 V  
1: +V, 2: 0 V  
1: +V, 4: 0 V  
1: +V, 2: 0 V  
1: +V, 4: 0 V  
1: +V, 2: 0 V  
1: +V, 4: 0 V  
A
D
M12 Connector Mod-  
els  
---  
---  
E2E-X2D2-M1G  
E2E-X2D1-M3G  
M8 Connector Models  
I
E2E-X2D2-M3G  
E2E-X3D1-M1TGJ-U 0.3M  
E2E-X3D2-M1TGJ-U 0.3M  
E2E-X3D1-M1TGJ 0.3M  
E2E-X3D1-U 2M  
PUR (increased  
oil-resistant)  
M12 Pre-wired Smart-  
click Connector Mod-  
els (0.3m)  
H
G
PVC (oil-resistant)  
PUR (increased  
oil-resistant)  
Yes  
E2E-X3D2-U 2M  
Pre-wired Models  
(2 m)  
---  
---  
E2E-X3D1-N 2M *1*2*3  
E2E-X3D2-N 2M *3  
E2E-X3D1-M1G *1  
PVC (oil-resistant)  
---  
M12  
3 mm  
1: +V, 4: 0 V  
1: +V, 2: 0 V  
1: +V, 4: 0 V  
1: +V, 2: 0 V  
(3, 4): (+V, 0 V)  
(1, 2): (+V, 0 V)  
1: +V, 4: 0 V  
1: +V, 2: 0 V  
1: +V, 4: 0 V  
A
D
A
D
C
D
M12 Connector Mod-  
els  
E2E-X3D2-M1G  
E2E-X3D1-M1GJ 0.3M  
E2E-X3D2-M1GJ 0.3M  
E2E-X3D1-M1J-T 0.3M  
---  
E2E-X7D1-M1TGJ-U 0.3M  
E2E-X7D2-M1TGJ-U 0.3M  
E2E-X7D1-M1TGJ 0.3M  
E2E-X7D1-U 2M  
Yes  
M12 Standard Pre-  
wired Connector Mod- PVC (oil-resistant)  
els (0.3 m) *6  
No *5  
PUR (increased  
oil-resistant)  
M12 Pre-wired Smart-  
H
G
click Connector Mod-  
els (0.3m)  
PVC (oil-resistant)  
PUR (increased  
oil-resistant)  
Yes  
E2E-X7D2-U 2M  
Pre-wired Models  
(2 m)  
---  
---  
E2E-X7D1-N 2M *1*2*3  
E2E-X7D2-N 2M *3  
E2E-X7D1-M1G *1  
PVC (oil-resistant)  
M18  
7 mm  
1: +V, 4: 0 V  
1: +V, 2: 0 V  
1: +V, 4: 0 V  
1: +V, 2: 0 V  
(3, 4): (+V, 0 V)  
(1, 2): (+V, 0 V)  
1: +V, 4: 0 V  
1: +V, 2: 0 V  
1: +V, 4: 0 V  
A
D
A
D
C
D
M12 Connector Mod-  
els  
---  
E2E-X7D2-M1G  
E2E-X7D1-M1GJ 0.3M  
E2E-X7D2-M1GJ 0.3M  
E2E-X7D1-M1J-T 0.3M  
E2E-X7D2-M1J-T 0.3M  
E2E-X10D1-M1TGJ-U 0.3M  
E2E-X10D2-M1TGJ-U 0.3M  
E2E-X10D1-M1TGJ 0.3M  
E2E-X10D1-U 2M  
Yes  
M12 Standard Pre-  
wired Connector Mod- PVC (oil-resistant)  
els (0.3 m) *6  
No *5  
PUR (increased  
oil-resistant)  
M12 Pre-wired Smart-  
H
G
click Connector Mod-  
els (0.3m)  
PVC (oil-resistant)  
PUR (increased  
oil-resistant)  
Yes  
E2E-X10D2-U 2M  
Pre-wired Models  
(2 m)  
---  
---  
E2E-X10D1-N 2M *1*2*3  
E2E-X10D2-N 2M  
PVC (oil-resistant)  
M30  
10 mm  
1: +V, 4: 0 V  
1: +V, 2: 0 V  
1: +V, 4: 0 V  
1: +V, 2: 0 V  
(3, 4): (+V, 0 V)  
(1, 2): (+V, 0 V)  
A
D
A
D
C
D
E2E-X10D1-M1G *1  
E2E-X10D2-M1G  
M12 Connector Mod-  
els  
---  
E2E-X10D1-M1GJ 0.3M  
E2E-X10D2-M1GJ 0.3M  
E2E-X10D1-M1J-T 0.3M  
E2E-X10D2-M1J-T 0.3M  
Yes  
M12 Standard Pre-  
wired Connector Mod- PVC (oil-resistant)  
els (0.3 m) *6  
No *5  
*1. Models with different frequencies are also available. The model number is E2E-X @D15 (example: E2E-X3D15-N 2M).  
*2. Models with a flexible cable are also available. Add "-R" rather than "-N" to the end of the model number (example: E2E-X2D1-R 2M).  
*3. The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X3D1-N 5M)  
*4. Refer to page 24 for details.  
*5. The residual voltage for models without polarity is 5 V, so use caution concerning the connection load interface conditions (e.g., PLC ON voltage). Refer to page 28.  
*6. The standard cable length is 300 mm. Cables with a length of 500 mm and 1 m can also be manufactured.  
7
E2E  
2-Wire Models  
Unshielded DC 2-Wire Models with No Self-diagnosis Output [Refer to Dimensions on page 29.]  
Opera-  
tion  
mode  
Applicable  
connector  
code *4  
Appear-  
ance  
Connection  
method  
Cable  
specifications  
Polar-  
ity  
Pin  
arrangement  
Sensing distance  
Model  
NO  
NC  
NO  
NC  
NO  
NC  
E2E-X4MD1 2M *2*3  
E2E-X4MD2 2M  
Pre-wired Models (2 m) PVC (oil-resistant)  
---  
---  
1: +V, 4: 0 V  
1: +V, 2: 0 V  
1: +V, 4: 0 V  
1: +V, 2: 0 V  
A
D
E2E-X4MD1 2M  
M8  
M12 Connector Models  
---  
---  
4 mm  
E2E-X4MD2-M1G  
E2E-X4MD1-M3G  
E2E-X4MD2-M3G  
M8 Connector Models  
12M Pre-wired Smart-  
click Connector Models PVC (oil-resistant)  
(0.3m)  
I
NO  
1: +V, 4: 0 V  
---  
G
---  
E2E-X8MD1-M1TGJ 0.3M  
NO  
NC  
NO  
NC  
NO  
E2E-X8MD1 2M *1*2*3  
E2E-X8MD2 2M  
Pre-wired Models (2 m) PVC (oil-resistant)  
M12  
8 mm  
1: +V, 4: 0 V  
1: +V, 2: 0 V  
1: +V, 4: 0 V  
A
D
A
E2E-X8MD1-M1G *1  
E2E-X8MD2-M1G  
M12 Connector Models  
M12 Standard Pre-  
---  
E2E-X8MD1-M1GJ 0.3M  
wired Connector Mod- PVC (oil-resistant)  
els (0.3 m)  
NC  
1: +V, 2: 0 V  
D
---  
12M Pre-wired Smart-  
click Connector Models PVC (oil-resistant)  
(0.3m)  
NO  
1: +V, 4: 0 V  
G
E2E-X14MD1-M1TGJ 0.3M  
Yes  
NO  
NC  
NO  
NC  
NO  
E2E-X14MD1 2M *1*2*3  
E2E-X14MD2 2M  
Pre-wired Models (2 m) PVC (oil-resistant)  
---  
---  
M18  
14 mm  
1: +V, 4: 0 V  
1: +V, 2: 0 V  
1: +V, 4: 0 V  
A
D
A
E2E-X14MD1-M1G *1  
E2E-X14MD2-M1G  
M12 Connector Models  
M12 Standard Pre-  
---  
E2E-X14MD1-M1GJ 0.3M  
wired Connector Mod- PVC (oil-resistant)  
els (0.3 m)  
NC  
1: +V, 2: 0 V  
D
E2E-X14MD2-M1GJ 0.3M  
12M Pre-wired Smart-  
click Connector Models PVC (oil-resistant)  
(0.3m)  
NO  
1: +V, 4: 0 V  
G
E2E-X20MD1-M1TGJ 0.3M  
NO  
NC  
NO  
NC  
NO  
E2E-X20MD1 2M *1*2*3  
E2E-X20MD2 2M  
Pre-wired Models (2 m) PVC (oil-resistant)  
---  
---  
M30  
20 mm  
1: +V, 4: 0 V  
1: +V, 2: 0 V  
1: +V, 4: 0 V  
A
D
A
E2E-X20MD1-M1G *1  
E2E-X20MD2-M1G  
M12 Connector Models  
M12 Standard Pre-  
---  
E2E-X20MD1-M1GJ 0.3M  
wired Connector Mod- PVC (oil-resistant)  
els (0.3 m)  
NC  
1: +V, 2: 0 V  
D
---  
*1. Models with different frequencies are also available. The model number is E2E-X @D15 (example: E2E-X8MD15 2M).  
*2. Models with a flexible cable are also available. Add -R to the end of the model number. (example: E2E-X4MD1-R 2M).  
*3. The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X4MD1 5M)  
*4. Refer to page 24 for details.  
Shielded DC 2-Wire Models with Self-diagnosis Output [Refer to Dimensions on page 29.]  
Opera-  
tion  
mode  
Applicable  
connector  
code *2  
Appear-  
ance  
Connection  
method  
Cable  
specifications  
Polar-  
ity  
Pin  
arrangement  
Sensing distance  
Model  
Pre-wired Models  
(2 m)  
PVC (oil-resistant)  
---  
---  
E2E-X3D1S 2M *1  
E2E-X3D1S-M1  
E2E-X7D1S 2M *1  
E2E-X7D1S-M1  
E2E-X10D1S 2M *1  
E2E-X10D1S-M1  
M12  
M18  
M30  
3 mm  
2: +V and diagnostic output  
3: 0 V  
4: +V and control output  
M12 Connector  
Models  
---  
D
Pre-wired Models  
(2 m)  
PVC (oil-resistant)  
---  
---  
D
Yes  
NO  
7 mm  
2: +V and diagnostic output  
3: 0 V  
4: +V and control output  
M12 Connector  
Models  
---  
PVC (oil-resistant)  
---  
Pre-wired Models  
(2 m)  
---  
---  
D
10 mm  
2: +V and diagnostic output  
3: 0 V  
4: +V and control output  
M12 Connector  
Models  
*1. Models with different frequencies are also available. The model number is E2E-X @D15S (example: E2E-X3D15S 2M).  
*2. Refer to page 24 for details.  
8
E2E  
2-Wire Models  
Unshielded DC 2-Wire Models with Self-diagnosis Output [Refer to Dimensions on page 29.]  
Opera-  
Applicable  
connector  
code *2  
Appear-  
ance  
Connection  
method  
Cable  
specifications  
Polar-  
ity  
Pin  
arrangement  
Sensing distance  
tion  
Model  
mode  
Pre-wired Mod-  
els (2 m)  
PVC (oil-resistant)  
---  
---  
E2E-X8MD1S 2M *  
E2E-X8MD1S-M1  
E2E-X14MD1S 2M *  
E2E-X14MD1S-M1  
E2E-X20MD1S 2M *  
E2E-X20MD1S-M1  
M12  
M18  
M30  
8 mm  
2: +V and diagnostic output  
3: 0 V  
4: +V and control output  
M12 Connector  
Models  
---  
D
Pre-wired Mod-  
els (2 m)  
PVC (oil-resistant)  
---  
---  
D
Yes  
NO  
14 mm  
2: +V and diagnostic output  
3: 0 V  
4: +V and control output  
M12 Connector  
Models  
---  
PVC (oil-resistant)  
---  
Pre-wired Mod-  
els (2 m)  
---  
---  
D
20 mm  
2: +V and diagnostic output  
3: 0 V  
4: +V and control output  
M12 Connector  
Models  
*1. Models with different frequencies are also available. The model number is E2E-X @MD15S (example: E2E-X8MD15S 2M).  
*2. Refer to page 24 for details.  
Connector Pin Assignments of DC 2-Wire Models  
The connector pin assignments of each New E2E DC 2-Wire Model  
Cable length  
Model  
XS2W-D421-BY1  
conform to IEC 947-5-2 Table III. (Only DC 2-Wire Models have  
been changed in comparison to the previous models.)  
The following models with conventional connector pin assignments  
are available as well. (Only NO Models can be used.)  
The cable at the right should also be used if the XW3A-P@45-G11  
Connector Junction Box is already being used.  
500 mm  
Internal Wiring  
(Proximity Sensor end)  
(Wired end)  
1
4
4
3
Models with conventional connector pin assignments are available as well.  
Appearance  
Model  
NO  
Applicable connector code *  
NC  
Applicable connector code *  
M8  
E2E-X2D1-M1  
C
C
C
C
C
C
C
C
E2E-X2D2-M1  
D
Shielded  
M12  
M18  
M30  
M8  
E2E-X3D1-M1  
E2E-X3D2-M1  
D
D
D
D
D
D
D
E2E-X7D1-M1  
E2E-X7D2-M1  
E2E-X10D1-M1  
E2E-X4MD1-M1  
E2E-X8MD1-M1  
E2E-X14MD1-M1  
E2E-X20MD1-M1  
E2E-X10D2-M1  
E2E-X4MD2-M1  
E2E-X8MD2-M1  
E2E-X14MD2-M1  
E2E-X20MD2-M1  
Unshielded  
M12  
M18  
M30  
Note: Refer to page 24 for details.  
9
E2E  
2-Wire Models  
AC 2-Wire Models Shielded Models [Refer to Dimensions on page 29.]  
Appear-  
ance  
Connection  
method  
Cable  
specifications  
Operation  
mode  
Pin  
arrangement  
Applicable con-  
nector code *3  
Sensing distance  
Model  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
E2E-X1R5Y1 2M  
E2E-X1R5Y2 2M  
E2E-X2Y1 2M *1*2  
E2E-X2Y2 2M  
Pre-wired Models  
(2 m)  
M8  
PVC (oil-resistant)  
---  
---  
---  
---  
1.5 mm  
Pre-wired Models  
(2 m)  
PVC (oil-resistant)  
M12  
2 mm  
(3, 4): (AC, AC)  
(1, 2): (AC, AC)  
E
F
E2E-X2Y1-M1  
M12 Connector  
Models  
---  
E2E-X2Y2-M1  
E2E-X5Y1 2M *1*2  
E2E-X5Y2 2M  
Pre-wired Models  
(2 m)  
PVC (oil-resistant)  
---  
---  
M18  
M30  
5 mm  
(3, 4): (AC, AC)  
(1, 2): (AC, AC)  
E
F
E2E-X5Y1-M1  
M12 Connector  
Models  
---  
PVC (oil-resistant)  
---  
E2E-X5Y2-M1  
E2E-X10Y1 2M *1*2  
E2E-X10Y2 2M  
E2E-X10Y1-M1  
E2E-X10Y2-M1  
Pre-wired Models  
(2 m)  
---  
---  
10 mm  
(3, 4): (AC, AC)  
(1, 2): (AC, AC)  
E
F
M12 Connector  
Models  
*1. Models with different frequencies are also available. The model number is E2E-X @Y@5 (example: E2E-X5Y15 2M).  
*2. The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X2Y1 5M)  
*3. Refer to page 24 for details.  
Unshielded Models  
Appear-  
ance  
Connection  
method  
Cable  
Operation  
mode  
Pin  
Applicable con-  
nector code *3  
Sensing distance  
Model  
E2E-X2MY1 2M  
E2E-X2MY2 2M  
specifications  
arrangement  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
Pre-wired Models  
(2 m)  
M8  
PVC (oil-resistant)  
---  
---  
---  
---  
2 mm  
E2E-X5MY1 2M *1*2  
E2E-X5MY2 2M  
Pre-wired Models  
(2 m)  
PVC (oil-resistant)  
M12  
5 mm  
(3, 4): (AC, AC)  
(1, 2): (AC, AC)  
E
F
E2E-X5MY1 2M  
M12 Connector  
Models  
---  
E2E-X5MY2-M1  
E2E-X10MY1 2M *1  
E2E-X10MY2 2M  
E2E-X10MY1-M1  
E2E-X10MY2-M1  
E2E-X18MY1 2M *1  
E2E-X18MY2 2M  
E2E-X18MY1-M1  
E2E-X18MY2-M1  
Pre-wired Models  
(2 m)  
PVC (oil-resistant)  
---  
---  
M18  
M30  
10 mm  
(3, 4): (AC, AC)  
(1, 2): (AC, AC)  
E
F
M12 Connector  
Models  
---  
PVC (oil-resistant)  
---  
Pre-wired Models  
(2 m)  
---  
---  
18 mm  
(3, 4): (AC, AC)  
(1, 2): (AC, AC)  
E
F
M12 Connector  
Models  
*1. Models with different frequencies are also available. The model number is E2E-X @MY@5 (example: E2E-X5MY15 2M).  
*2. The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X5MY1 5M)  
*3. Refer to page 24 for details.  
AC 2-Wire Models Shielded Models [Refer to Dimensions on page 29.]  
(There are no unshielded models.)  
Appear-  
ance  
Connection  
method  
Cable  
Operation  
mode  
Pin  
Applicable con-  
nector code *3  
Sensing distance  
Model  
E2E-X3T1 2M  
specifications  
arrangement  
Pre-wired Models PVC (oil-resis-  
(2 m) tant)  
M12  
M18  
M30  
---  
---  
---  
---  
---  
---  
3 mm  
7 mm  
Pre-wired Models PVC (oil-resis-  
(2 m) tant)  
NO  
E2E-X7T1 2M *  
E2E-X10T1 2M  
Pre-wired Models PVC (oil-resis-  
(2 m) tant)  
10 mm  
Note: Not compliant with CE.  
* The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X7T1 5M)  
10  
E2E  
3-Wire Models  
Shielded DC 3-Wire Models [Refer to Dimensions on page 29.]  
Appli-  
cable  
connec-  
torcode  
*5  
Model  
Cable  
specifica-  
tions  
Opera-  
Appear-  
ance  
Connection  
method  
Pin  
arrangement  
Sensing distance  
tion  
NPN output  
PNP output  
mode  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
E2E-CR6C1 2M  
E2E-CR6C2 2M  
E2E-CR8C1 2M *1*2  
E2E-CR8C2 2M  
E2E-X1C1 2M *1*2  
E2E-X1C2 2M  
E2E-CR6B1 2M  
E2E-CR6B2 2M  
E2E-CR8B1 2M *2  
E2E-CR8B2 2M  
E2E-X1B1 2M *2  
E2E-X1B2 2M  
Pre-wired Models PVC (oil-re-  
(2 m) sistant)  
3 dia.  
4 dia.  
M5  
---  
---  
---  
---  
---  
---  
---  
---  
0.6 mm  
Pre-wired Models PVC (oil-re-  
(2 m) sistant)  
0.8 mm  
1 mm  
Pre-wired Models PVC (oil-re-  
(2 m) sistant)  
E2E-C1C1 2M *1*2  
E2E-C1C2 2M  
E2E-C1B1 2M  
Pre-wired Models PVC (oil-re-  
5.4 dia.  
1 mm  
(2 m)  
sistant)  
E2E-C1B2 2M  
PVC (oil-re-  
sistant)  
NO  
NC  
NO  
NC  
NO  
NC  
E2E-X1R5E1 2M *1*2 E2E-X1R5F1 2M *1*2  
Pre-wired Models  
(2 m)  
---  
---  
PVC (oil-re-  
sistant)  
E2E-X1R5E2 2M  
E2E-X1R5E1-M1  
E2E-X1R5E2-M1  
E2E-X1R5E1-M3  
E2E-X1R5E2-M3  
E2E-X1R5F2 2M  
E2E-X1R5F1-M1  
E2E-X1R5F2-M1  
E2E-X1R5F1-M3  
E2E-X1R5F2-M3  
1: +V, 3: 0 V,  
4: Control output  
B
D
M12 Connector  
Models  
M8  
---  
---  
1.5 mm  
1: +V, 3: 0 V,  
2: Control output  
1: +V, 3: 0 V,  
4: Control output  
M8 Connector  
Models  
I
1: +V, 3: 0 V,  
2: Control output  
NO  
NC  
E2E-X2E1 2M *1*2*3  
E2E-X2E2 2M  
E2E-X2F1 2M *1*2*3  
E2E-X2F2 2M  
Pre-wired Models PVC (oil-re-  
---  
---  
(2 m)  
sistant)  
1: +V, 3: 0 V,  
M12  
M18  
M30  
2 mm  
5 mm  
NO  
NC  
E2E-X2E1-M1  
E2E-X2E2-M1  
E2E-X2F1-M1  
E2E-X2F2-M1  
B
D
4: Control output  
M12 Connector  
Models  
---  
1: +V, 3: 0 V,  
2: Control output  
NO  
NC  
E2E-X5E1 2M *1*2*3  
E2E-X5E2 2M  
E2E-X5F1 2M *1*2*3  
E2E-X5F2 2M  
Pre-wired Models PVC (oil-re-  
(2 m)  
---  
---  
sistant)  
1: +V, 3: 0 V,  
4: Control output  
NO  
NC  
E2E-X5E1-M1  
E2E-X5E2-M1  
E2E-X5F1-M1  
E2E-X5F2-M1  
B
D
M12 Connector  
Models  
---  
1: +V, 3: 0 V,  
2: Control output  
NO  
NC  
E2E-X10E1 2M *1*2*3 E2E-X10F1 2M *2  
Pre-wired Models PVC (oil-re-  
(2 m)  
---  
---  
sistant)  
E2E-X10E2 2M  
E2E-X10F2 2M  
1: +V, 3: 0 V,  
4: Control output  
10 mm  
NO  
NC  
E2E-X10E1-M1  
E2E-X10F1-M1  
B
D
M12 Connector  
Models  
---  
1: +V, 3: 0 V,  
2: Control output  
E2E-X10E2-M1  
E2E-X10F2-M1  
*1. The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X2E1 5M)  
*2. Models with a flexible cable are also available. Add -R to the end of the model number. (example: E2E-X5E1-R 2M).  
*3. Models with different frequencies are also available. The model number is E2E-X@@@5 (example: E2E-X5E15 2M).  
*4. Refer to page 24 for details.  
11  
E2E  
3-Wire Models  
Unshielded DC 3-Wire Models [Refer to Dimensions on page 29.]  
Appli-  
cable  
connec-  
torcode  
*5  
Model  
Opera-  
tion  
mode  
Appear-  
ance  
Connection  
method  
Cable  
specifications  
Pin  
arrangement  
Sensing distance  
NPN output  
PNP output  
NO  
NC  
E2E-X2ME1 2M *2 E2E-X2MF1 2M *2  
Pre-wired Models PVC (oil-resis-  
---  
---  
(2 m)  
tant)  
E2E-X2ME2 2M  
E2E-X2ME1-M1  
E2E-X2MF2 2M  
E2E-X2MF1-M1  
1: +V, 3: 0 V,  
4: Control output  
NO  
NC  
NO  
NC  
B
D
M12 Connector  
Models  
---  
---  
1: +V, 3: 0 V,  
2: Control output  
M8  
2 mm  
E2E-X2ME2-M1  
E2E-X2ME1-M3  
E2E-X2ME2-M3  
E2E-X2MF2-M1  
E2E-X2MF1-M3  
E2E-X2MF2-M3  
1: +V, 3: 0 V,  
4: Control output  
M8 Connector  
Models  
I
1: +V, 3: 0 V,  
2: Control output  
E2E-X5ME1 2M  
*1*2*3  
NO  
NC  
NO  
E2E-X5MF1 2M *2  
E2E-X5MF2 2M  
E2E-X5MF1-M1  
Pre-wired Models PVC (oil-resis-  
---  
---  
(2 m)  
tant)  
E2E-X5ME2 2M  
M12  
M18  
M30  
5 mm  
1: +V, 3: 0 V,  
4: Control output  
E2E-X5ME1-M1  
B
D
M12 Connector  
Models  
---  
1: +V, 3: 0 V,  
2: Control output  
NC  
E2E-X5ME2-M1  
E2E-X5MF2-M1  
E2E-X10ME1 2M  
*1*2*3  
NO  
NC  
NO  
E2E-X10MF1 2M *2  
E2E-X10MF2 2M  
E2E-X10MF1-M1  
Pre-wired Models PVC (oil-resis-  
---  
---  
(2 m)  
tant)  
E2E-X10ME2 2M  
10 mm  
1: +V, 3: 0 V,  
4: Control output  
E2E-X10ME1-M1  
B
D
M12 Connector  
Models  
---  
1: +V, 3: 0 V,  
2: Control output  
NC  
E2E-X10ME2-M1  
E2E-X10MF2-M1  
E2E-X18ME1 2M  
*1*2*3  
NO  
NC  
NO  
E2E-X18MF1 2M *2  
E2E-X18MF2 2M  
E2E-X18MF1-M1  
Pre-wired Models PVC (oil-resis-  
---  
---  
(2 m)  
tant)  
E2E-X18ME2 2M  
18 mm  
1: +V, 3: 0 V,  
4: Control output  
E2E-X18ME1-M1  
B
D
M12 Connector  
Models  
---  
1: +V, 3: 0 V,  
2: Control output  
NC  
E2E-X18ME2-M1  
E2E-X18MF2-M1  
*1. The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X5ME1 5M)  
*2. Models with a flexible cable are also available. Add -R to the end of the model number. (example: E2E-X5E1-R 2M).  
*3. Models with different frequencies are also available. The model number is E2E-X@M@@5 (example: E2E-X5ME15 2M).  
*4. Refer to page 24 for details.  
12  
E2E  
Ratings and Specifications  
E2E-X@D@ DC 2-Wire Models  
Size  
M8  
M12  
M18  
M30  
Shielded  
Shielded  
Unshielded  
Shielded  
E2E-X3D@  
3 mm 10%  
0 to 2.4 mm  
Unshielded  
Shielded  
E2E-X7D@  
7 mm 10%  
0 to 5.6 mm  
Unshielded  
Shielded  
Unshielded  
Item  
Model E2E-X2D@  
E2E-X4MD@  
4 mm 10%  
0 to 3.2 mm  
E2E-X8MD@  
8 mm 10%  
0 to 6.4 mm  
E2E-X14MD@ E2E-X10D@  
E2E-X20MD@  
20 mm 10%  
0 to 16 mm  
Sensing distance  
Set distance *1  
2 mm 10%  
0 to 1.6 mm  
14 mm 10%  
0 to 11.2 mm  
10 mm 10%  
0 to 8 mm  
Differential travel  
Detectable object  
15% max. of sensing distance  
10% max. of sensing distance  
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on pages 18 and 19.  
Standard sensing  
object  
Iron,  
8 × 8 × 1 mm  
Iron,  
Iron,  
Iron,  
Iron,  
Iron,  
54 × 54 × 1 mm  
Iron, 30 × 30 × 1 mm  
20 × 20 × 1 mm 12 × 12 × 1 mm 30 × 30 × 1 mm 18 × 18 × 1 mm  
Response frequency  
*2  
1.5 kHz  
1 kHz 0.8 kHz 0.5 kHz  
0.4 kHz  
0.1 kHz  
Power supply voltage  
(operating voltage  
range)  
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.  
Leakage current  
0.8 mA max.  
Load  
current  
3 to 100 mA, Diagnostic output: 50 mA for -D1(5)S Models  
Control  
output  
Residual  
voltage  
*3  
3 V max. (Load current: 100 mA, Cable length: 2 m, M1J-T Models only: 5 V max.)  
D1 Models: Operation indicator (red) and setting indicator (green)  
D2 Models: Operation indicator (red)  
Indicators  
Operation mode  
(with sensing object  
approaching)  
D1 Models: NO  
D2 Models: NC  
Refer to the timing charts under I/O Circuit Diagrams on page 21 for details.  
Diagnostic output  
delay  
0.3 to 1 s  
Protection circuits  
Surge suppressor, Load short-circuit protection (for control and diagnostic output)  
Ambient  
temperature range  
Operating: 25 to 70°C, Storage: 40 to 85°C (with no icing or condensation)  
Ambient  
Operating/storage: 35% to 95% (with no condensation)  
15% max. of sensing distance  
humidity range  
Temperature  
influence  
at 23°C in the temperature range  
10% max. of sensing distance at 23°C in the temperature range of 25 to 70°C  
of 25 to 70°C  
Voltage influence  
1% max. of sensing distance at rated voltage in the rated voltage 15% range  
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case  
Dielectric strength  
Vibration resistance  
1000 VAC, 50/60 Hz for 1 minute between current carry parts and case  
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions  
Destruction: 500 m/s2  
Shock resistance  
10 times each in X, Y, and  
Z directions  
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions  
Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant  
Connector Models: IEC 60529 IP67  
Degree of protection  
Connection method  
Pre-wired Models (Standard cable length: 2 m), Connector Models, or Pre-wired Connector Models (Standard cable length: 0.3 m)  
Pre-wired  
Models  
Approx. 60 g  
Approx. 70 g  
Approx. 40 g  
Approx. 130 g  
Approx. 70 g  
Approx. 40 g  
Approx. 175 g  
Approx. 110 g  
Approx. 90 g  
Weight  
Pre-wired  
(pack-  
Connector  
ed  
---  
Models  
state)  
Connector  
Models  
Approx. 15 g  
Approx. 25 g  
Case  
Stainless steel (SUS303)  
PBT  
Nickel-plated brass  
Sensing sur-  
face  
Materi-  
als  
Clamping  
nuts  
Nickel-plated brass  
Toothed  
washer  
Zinc-plated iron  
Accessories  
Instruction manual  
*1. Use the E2E within the range in which the setting indicator (green LED) is ON (except D2 Models).  
*2. The response frequency is an average value.  
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.  
*3. The residual voltage of each M1J-T Model is 5 V. When connecting to a device, make sure that the device can withstand the residual voltage. (Refer to page 28 for  
details.)  
13  
E2E  
E2E-X@Y@ AC 2-Wire Models  
Size  
M8  
M12  
M18  
M30  
Shielded  
Shielded  
Unshielded  
Shielded  
Unshielded  
Shielded  
Unshielded  
Shielded  
Unshielded  
Item  
Model E2E-X1R5Y@  
E2E-X2MY@  
2 mm 10%  
0 to 1.6 mm  
E2E-X2Y@  
E2E-X5MY@  
5 mm 10%  
0 to 4 mm  
E2E-X5Y@  
E2E-X10MY@ E2E-X10Y@  
10 mm 10%  
E2E-X18MY@  
18 mm 10%  
0 to 14 mm  
Sensing distance  
Set distance  
1.5 mm 10%  
0 to 1.2 mm  
0 to 8 mm  
Differential travel  
Detectable object  
10% max. of sensing distance  
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 19.)  
Standard sensing  
object  
Iron,  
8 × 8 × 1 mm  
Iron,  
Iron,  
Iron,  
54 × 54 × 1 mm  
Iron, 12 × 12 × 1 mm  
Iron, 30 × 30 × 1 mm  
15 × 15 × 1 mm 18 × 18 × 1 mm  
Response frequency  
25 Hz  
Power supply voltage  
(operating voltage  
range)*1  
24 to 240 VAC (20 to 264 VAC), 50/60 Hz  
1.7 mA max.  
Leakage current  
Load  
5 to 100 mA  
5 to 200 mA  
5 to 300 mA  
current *2  
Control  
output  
Residual  
voltage  
Refer to Engineering Data on page 20.  
Operation indicator (red)  
Y1 Models: NO  
Indicators  
Operation mode  
(with sensing object  
approaching)  
Refer to the timing charts under I/O Circuit Diagrams on page 23 for details.  
Y2 Models: NC  
Protection circuits  
Surge suppressor  
Ambient temperature Operating/Storage: 25 to 70°C  
Operating/Storage: 40 to 85°C (with no icing or condensation)  
range *1*2  
(with no icing or condensation)  
Ambient  
Operating/storage: 35% to 95% (with no condensation)  
10% max. of sensing distance  
humidity range  
Temperature  
influence  
15% max. of sensing distance at 23°C in the temperature range of 40 to 85°C,  
at 23°C in the temperature range  
10% max. of sensing distance at 23°C in the temperature range of 25 to 70°C  
of 25 to 70°C  
Voltage influence  
1% max. of sensing distance at rated voltage in the rated voltage 15% range  
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case  
Dielectric strength  
Vibration resistance  
4,000 VAC (M8 Models: 2,000 VAC), 50/60 Hz for 1 min between current-carrying parts and case  
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions  
Destruction: 500 m/s2  
Shock resistance  
10 times each in X, Y, and  
Z directions  
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions  
Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant  
Connector Models: IEC 60529 IP67  
Degree of protection  
Connection method  
Pre-wired Models (Standard cable length: 2 m) and Connector Models  
Pre-  
wired  
Models  
Approx. 60 g  
Approx. 15 g  
Approx. 70 g  
Approx. 130 g  
Approx. 40 g  
Approx. 175 g  
Approx. 90 g  
Model  
Weight  
Connec-  
tor  
Models  
Approx. 25 g  
Case  
Stainless steel (SUS303)  
PBT  
Nickel-plated brass  
Sensing  
surface  
Materials  
Clamp-  
ing nuts  
Nickel-plated brass  
Toothed  
washer  
Zinc-plated iron  
Accessories  
Instruction manual  
*1. When supplying 24 VAC to any of the above models, make sure that the operating ambient temperature range is at least 25°C.  
*2. When using an M18 or M30 Connector Model at an ambient temperature between 70 and 85°C, make sure that the Sensor has a control output (load current) of  
5 to 200 mA max.  
14  
E2E  
E2E-X@T1 AC/DC 2-Wire Models  
Size  
M12  
M18  
M30  
Shielded  
Shielded  
E2E-X7T1  
Item  
Model  
E2E-X3T1  
E2E-X10T1  
Sensing distance  
Set distance  
3 mm 10%  
0 to 2.4 mm  
7 mm 10%  
0 to 5.6 mm  
10 mm 10%  
0 to 8 mm  
Differential travel  
Detectable object  
10% max. of sensing distance  
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 18.)  
Standard sensing object  
Iron, 12 × 12 × 1 mm  
Iron, 18 × 18 × 1 mm  
Iron, 30 × 30 × 1 mm  
DC  
AC  
1 kHz  
0.5 kHz  
0.4 kHz  
Response  
frequency *1  
25 Hz  
Power supply voltage  
24 to 240 VDC (20 to 264 VDC)  
(operating voltage range) *2 48 to 240 VAC (40 to 264 VAC)  
DC: 1 mA max.  
Leakage current  
AC: 2 mA max.  
Load  
current  
5 to 100 mA  
Control  
output  
Residual  
voltage  
DC: 6 V max. (Load current: 100 mA, Cable length: 2 m)  
AC: 10 V max. (Load current: 5 mA, Cable length: 2 m)  
Indicators  
Operation indicator (red), Setting indicator (green)  
Operation mode  
(with sensing object  
approaching)  
NO (Refer to the timing charts under I/O Circuit Diagrams on page 21 for details.)  
Protection circuits  
Load short-circuit protection (20 to 40 VDC only), Surge suppressor  
Ambient temperature range Operating: 25 to 70°C, Storage: 40 to 85°C (with no icing or condensation)  
Ambient humidity range  
Temperature influence  
Voltage influence  
Insulation resistance  
Dielectric strength  
Vibration resistance  
Shock resistance  
Degree of protection  
Connection method  
Weight (packed state)  
Case  
Operating/Storage: 35% to 95% (with no condensation)  
10% max. of sensing distance at 23°C in the temperature range of 25 to 70°C  
1% max. of sensing distance at rated voltage in the rated voltage 15% range  
50 MΩ min. (at 500 VDC) between current-carrying parts and case  
4,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case  
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions  
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions  
IEC 60529 IP67, in-house standards: oil-resistant  
Pre-wired Models (Standard cable length: 2 m)  
Approx. 80 g  
Approx. 140 g  
Approx. 190 g  
Nickel-plated brass  
Sensing  
surface  
PBT  
Materials  
Clamping  
nuts  
Nickel-plated brass  
Toothed  
washer  
Zinc-plated iron  
Accessories  
Instruction manual  
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and  
a set distance of half the sensing distance.  
*2. Power Supply Voltage Waveform:  
Use a sine wave for the power supply. Using a rectangular AC power supply may result in faulty reset.  
15  
E2E  
E2E-X@E@/F@ DC 3-Wire Models  
Size  
M8  
M12  
M18  
M30  
Shielded  
Shielded  
E2E  
-X1R5E@/F@  
1.5 mm 10%  
0 to 1.2 mm  
Unshielded  
Shielded  
E2E  
-X2E@/F@  
Unshielded  
Shielded  
E2E  
-X5E@/F@  
Unshielded  
Shielded  
Unshielded  
E2E  
E2E  
E2E  
E2E-X10E@/  
F@  
E2E  
Item  
Model  
-X2ME@/F@  
2 mm 10%  
0 to 1.6 mm  
-X5ME@/F@  
5 mm 10%  
0 to 4 mm  
-X10ME@/F@  
10 mm 10%  
0 to 8 mm  
-X18ME@/F@  
18 mm 10%  
0 to 14 mm  
Sensing distance  
Set distance  
Differential travel  
Detectable object  
10% max. of sensing distance  
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on pages 18 and 19.)  
Standard sensing  
object  
Iron,  
Iron,  
Iron,  
Iron,  
Iron, 12 × 12 × 1 mm  
0.8 kHz 1.5 kHz  
Iron, 30 × 30 × 1 mm  
0.2 kHz 0.4 kHz  
8 × 8 × 1 mm  
15 ×15 × 1 mm 18 × 18 × 1 mm  
54 × 54 × 1 mm  
Response frequency  
*1  
2 kHz  
0.4 kHz 0.6 kHz  
0.1 kHz  
Power supply voltage  
(operating voltage  
range) *2  
12 to 24 VDC (10 to 40 VDC), ripple (p-p): 10% max.  
Current consumption 13 mA max.  
Load  
200 mA max.  
current *2  
Control  
output  
Residual  
2 V max. (Load current: 200 mA, Cable length: 2 m)  
voltage  
Indicators  
Operation indicator (red)  
Operation mode  
(with sensing object  
approaching)  
E1/F1 Models: NO  
E2/F2 Models: NC  
Refer to the timing charts under I/O Circuit Diagrams on page 21 for details.  
Protection circuits  
Load short-circuit protection, Surge suppressor, Reverse polarity protection  
Ambient  
temperature range *2  
Operating/Storage: 40 to 85°C (with no icing or condensation)  
Ambient humidity  
range  
Operating/Storage: 35% to 95% (with no condensation)  
Temperature  
influence  
15% max. of sensing distance at 23°C in the temperature range of 40 to 85°C  
10% max. of sensing distance at 23°C in the temperature range of 25 to 70°C  
Voltage influence  
1% max. of sensing distance at rated voltage in the rated voltage 15% range  
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case  
Dielectric strength  
Vibration resistance  
1,000 VAC, 50/60 Hz for 1 minute between current carry parts and case  
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions  
Destruction: 500 m/s2  
Shock resistance  
10 times each in X, Y, and  
Z directions  
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions  
Pre-wired Models : IEC 60529 IP67, in-house standards: oil-resistant  
Connector Models : IEC 60529 IP67  
Degree of protection  
Connection method  
Pre-wired Models (Standard cable length: 2 m) and Connector Models  
Pre-  
wired  
Approx. 65 g  
Approx. 15 g  
Approx. 75 g  
Approx. 150 g  
Approx. 40 g  
Approx. 195 g  
Approx. 90 g  
Models  
Weight  
Connec-  
tor  
Models  
Approx. 25 g  
Case  
Stainless steel (SUS303)  
PBT  
Nickel-plated brass  
Sensing  
surface  
Materials  
Clamp-  
ing nuts  
Nickel-plated brass  
Toothed  
washer  
Zinc-plated iron  
Accessories  
Instruction manual  
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and  
a set distance of half the sensing distance.  
*2. When using an M8 Model at an ambient temperature between 70 and 85°C, supply 10 to 30 VDC to the Sensor and make sure that the Sensor has a control output  
of 100 mA maximum.  
16  
E2E  
E2E-C@C/B@ and E2E-X1C/B@ DC 3-Wire Models  
Size  
Shielded  
Model  
3 dia.  
4 dia.  
M5  
5.4 dia.  
Shielded  
Item  
E2E-CR6C/B@  
E2E-CR8C/B@  
E2E-X1C/B@  
E2E-C1C/B@  
Sensing distance  
Set distance  
0.6 mm 15%  
0.8 mm 15%  
0 to 0.5 mm  
1 mm 15%  
0 to 0.7 mm  
0 to 0.4 mm  
Differential travel  
Detectable object  
15% max. of sensing distance  
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on pages 18 and 19.)  
Standard sensing ob-  
ject  
Iron, 3 × 3 × 1 mm  
Iron, 5 × 5 × 1 mm  
Response frequency * 2 kHz  
3 kHz  
Power supply voltage  
(operating voltage  
range)  
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.  
Current consumption 10 mA max.  
17 mA max.  
Load  
current  
Open-collector output,  
80 mA max. (30 VDC max.)  
Open-collector output, 100 mA max. (30 VDC max.)  
Control  
output  
1 V max.  
(Load current: 80 mA,  
Cable length: 2 m)  
Residual  
voltage  
2 V max. (Load current: 100 mA, Cable length: 2 m)  
Indicators  
Operation indicator (red)  
Operation mode  
(with sensing object  
approaching)  
C1/B1 Models: NO  
C2 Models: NC  
Refer to the timing charts under I/O Circuit Diagrams on page 22 for details.  
Protection circuits  
Reverse polarity protection, Surge suppressor  
Ambient  
temperature range  
Operating/Storage: 25 to 70°C (with no icing or condensation)  
Ambient humidity  
range  
Operating/Storage: 35% to 95% (with no condensation)  
Temperature influ-  
ence  
15% max. of sensing distance at 23°C in the temperature range of 25 to 70°C  
5% max. of sensing distance at  
rated voltage in the rated voltage  
10% range  
Voltage influence  
2.5% max. of sensing distance at rated voltage in the rated voltage 15% range  
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case  
Dielectric strength  
Vibration resistance  
Shock resistance  
500 VAC, 50/60 Hz for 1 min between current-carrying parts and case  
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions  
Destruction: 500 m/s2 10 times each in X, Y, and Z directions  
Degree of protection  
Connection method  
IEC 60529 IP66  
IEC 60529 IP67, in-house standards: oil-resistant  
Pre-wired Models (Standard cable length: 2 m)  
Weight (packed state) Approx. 60 g  
Case  
Stainless steel (SUS303)  
Nickel-plated brass  
Sensing  
surface  
Heat-resistant ABS  
Materials  
Clamping  
nuts  
Nickel-plated brass (E2E-X1C/B@ only)  
Toothed  
washer  
Zinc-plated iron (E2E-X1C/B@ only)  
Accessories  
Instruction manual  
* The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and  
a set distance of half the sensing distance.  
17  
E2E  
Engineering Data (Typical)  
Sensing Area  
Shielded Models  
E2E-X@D@/-X@T1  
12  
E2E-C@C@/-X@C@  
E2E-C@B1/-X@B@  
E2E-X@E@/-X@Y@/-X@F@  
12  
1.6  
Y
E2E-X10  
1.4  
E2E-X10  
X
10  
8
10  
1.2  
1.0  
0.8  
0.6  
0.4  
Y
8
X
E2E-X1/E2E-C1  
E2E-CR8  
E2E-X7  
6
6
E2E-X3  
E2E-X5  
E2E-X2  
E2E-X2  
Y
4
4
E2E-CR6  
X
E2E  
-X1R5  
2
0
2
0.2  
0
0
20 15 10  
5  
0
5
10  
15  
15  
10  
5  
0
5
10  
3.0  
2.0  
1.0  
0
1.0  
2.0  
Distance Y (mm)  
Distance Y (mm)  
Distance Y (mm)  
Unshielded Models  
E2E-X@MD@  
E2E-X@ME@/-X@MY@/-X@MF@  
30  
30  
Y
X
25  
20  
15  
25  
20  
E2E-X18M  
E2E  
-X20M  
15  
E2E  
-X14M  
E2E-X10M  
Y
10  
10  
X
E2E-X5M  
E2E  
-X8M  
E2E-X2M  
5
5
E2E  
-X4M  
0
30  
0
30  
20  
10  
0
10  
20  
20  
10  
0
10  
20  
Distance Y (mm)  
Distance Y (mm)  
Influence of Sensing Object Size and Material  
E2E-X2D@  
E2E-X3D@/-X3T1  
E2E-X7D@/-X7T1  
3.0  
d ×  
d
4.0  
8
d ×  
d ×  
d
t
= 1 mm  
d
t = 1 mm  
t = 1 mm  
Iron  
3.5  
X
7
6
5
4
3
2
1
X
X
2.5  
2.0  
1.5  
1.0  
0.5  
3.0  
2.5  
2.0  
1.5  
1.0  
0.5  
Iron  
Iron  
Stainless  
steel  
(SUS304)  
Stainless  
steel  
(SUS304)  
Stainless  
steel  
(SUS304)  
Brass  
Brass  
Aluminum  
Copper  
Aluminum  
Copper  
Brass  
Aluminum  
Copper  
0
5
10  
15  
20  
25  
0
5
10  
15  
20  
25  
30  
35 40  
0
10  
20  
30  
40  
50  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
E2E-X10D@/-X10T1  
E2E-X4MD@  
E2E-X8MD@  
6
12  
d ×  
d
12  
d ×  
d
d ×  
d
t = 1 mm  
t = 1 mm  
t = 1 mm  
X
X
X
Iron  
5
4
3
2
1
10  
10  
8
Iron  
8
6
4
2
Iron  
Stainless  
steel  
(SUS304)  
6
Stainless  
steel  
(SUS304)  
Stainless  
steel  
(SUS304)  
Brass  
Aluminum  
Copper  
4
Brass  
Aluminum  
Copper  
Brass  
Aluminum  
Copper  
2
0
10  
20  
30  
40  
50  
60  
70  
0
10  
20  
30  
40  
50  
60  
70  
0
10 15 20  
30  
40  
50  
60  
70  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
18  
E2E  
E2E-X14MD@  
E2E-X20MD@  
E2E-X1R5E@/-X1R5Y@/-X1R5F@  
25  
25  
2.5  
d ×  
d ×  
d ×  
d
d
d
t = 1 mm  
t = 1 mm  
X
t = 1 mm  
X
X
Iron  
20  
15  
10  
5
20  
15  
10  
5
2.0  
Iron  
1.5  
1.0  
0.5  
Iron  
Stainless  
steel  
(SUS304)  
Stainless steel  
(SUS304)  
Stainless  
steel  
(SUS304)  
Brass  
Aluminum  
Brass  
Aluminum  
Copper  
Brass  
Aluminum  
Copper  
0
10  
20  
30  
40  
50  
60  
70  
0
10 20 30 40 50 60 70 80 90100  
Side length of sensing object: d (mm)  
0
5
10  
15  
20  
25  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
E2E-X2E@/-X2Y@/-X2F@  
E2E-X5E@/-X5Y@/-X5F@  
E2E-X10E@/-X10Y@/-X10F@  
7
12  
2.5  
d ×  
d ×  
d ×  
d
d
d
t = 1 mm  
t = 1 mm  
t = 1 mm  
Iron  
6
5
4
3
2
1
X
X
X
Iron  
10  
2.0  
Iron  
Stainless steel  
(SUS304)  
8
Stainless steel (SUS304)  
Stainless steel  
(SUS304)  
1.5  
1.0  
0.5  
6
4
2
Brass  
Brass  
Brass  
Aluminum  
Aluminum  
Aluminum  
0
10  
20  
30  
40  
50  
0
10  
20  
30  
40  
50  
60  
0
5
10  
15  
20  
25  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
E2E-X2ME@/-X2MY@/-X2MF@  
E2E-X5ME@/-X5MY@/-X5MF@  
E2E-X10ME@/-X10MY@/-X10MF@  
12  
2.5  
7
d ×  
d ×  
d ×  
d
d
d
t = 1 mm  
t = 1 mm  
Iron  
t = 1 mm  
X
X
6
5
4
3
2
1
X
10  
8
Iron  
2.0  
1.5  
1.0  
0.5  
Iron  
Stainless steel  
(SUS304)  
Stainless steel  
(SUS304)  
Stainless steel (SUS304)  
6
Brass  
Aluminum  
Brass  
4
Brass  
Copper  
Aluminum  
Aluminum  
2
0
10  
20  
30  
40  
50  
60  
0
5
10  
15  
20  
25  
30  
0
10  
20  
30  
40  
50  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
E2E-X18ME@/-X18MY@/-X18MF@  
E2E-CR6@  
E2E-CR8@  
1.2  
25  
0.7  
d ×  
d ×  
d
d
t = 1 mm  
t = 1 mm  
X
X
Iron  
0.6  
0.5  
0.4  
1.0  
0.8  
0.6  
0.4  
0.2  
20  
Iron  
Stainless steel (SUS304)  
Iron  
15  
Brass  
Stainless steel (SUS304)  
Aluminum  
Stainless steel (SUS304)  
Brass  
0.3  
0.2  
0.1  
10  
Brass  
d ×  
d
Aluminum  
Copper  
t = 1 mm  
X
5
0
Aluminum  
0
5
10  
15  
20  
25  
30  
20  
40  
60  
80  
100  
0
5
10  
15  
20  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
19  
E2E  
E2E-X1@/-C1@  
1.2  
d ×  
d
t = 1 mm  
X
Iron  
1.0  
0.8  
0.6  
0.4  
0.2  
Stainless steel  
(SUS304)  
Brass  
Aluminum  
0
5
10  
15  
20  
25  
Side length of sensing object: d (mm)  
Leakage Current  
E2E-X@D@  
E2E-X@Y@  
E2E-X@T1  
1.0  
1.4  
1.4  
1.2  
1.0  
0.8  
0.6  
0.4  
1.2  
1.0  
0.8  
0.6  
0.4  
0.2  
AC power  
0.8  
E2E-X10D1-N  
0.6  
E2E-X3D1-N  
DC power  
0.4  
0.2  
Protective  
resistance  
E2E-X2D1-N  
mA  
~
E2E-X7D1-N  
V
AC  
power  
~
0.2  
Proximity  
Sensor (OFF)  
0
5
10  
15  
20  
25  
30  
0
50  
100  
150  
200  
250  
300  
0
50  
100  
150  
200  
250  
300  
Power supply voltage (V)  
Power supply voltage (V)  
Power supply voltage (V)  
Residual Output Voltage  
E2E-X@D@  
E2E-X@T1  
5
6
200 VAC  
4
100 VAC  
5
4
3
2
E2E-X@D1-M1J-T  
24 VDC  
3
2
E2E-X@D@  
1
0
1
3
5
10  
30  
50 100  
1
3
5
10  
30  
50 100  
Load current (mA)  
Load current (mA)  
E2E-X@Y@ at 24 VAC  
E2E-X@Y@ at 100 VAC  
E2E-X@Y@ at 200 VAC  
30  
120  
240  
Residual output voltage  
100  
Residual output voltage  
200  
25  
20  
15  
10  
ON  
ON  
80  
160  
Residual output voltage  
V
~
V
~
ON  
60  
120  
V
L
VL  
V
200 VAC  
~
100 VAC  
A
A
~
~
40  
20  
0
80  
40  
0
VL  
24 VAC  
OFF  
A
~
5
Residual  
load voltage  
Residual load  
voltage  
Residual load  
voltage  
OFF  
300 500  
Load current (mA)  
OFF  
0
1
3
5
10  
30 50 100  
300 500  
1
3
5
10  
30 50 100  
1
3
5
10  
30 50 100  
300 500  
Load current (mA)  
Load current (mA)  
20  
E2E  
I/O Circuit Diagrams  
E2E-X@D@ DC 2-Wire Models  
Operation  
mode  
Model  
Timing Chart  
Output circuit  
Polarity: Yes  
1
Load  
+V  
Brown  
E2E-X@D1-N  
Prox-  
imity  
Sensor  
main  
E2E-X@D1-M1G(J)  
E2E-X@D1-(M1TGJ)-U  
E2E-X@D1-M3G  
Set position  
Unstable  
sensing  
area  
Non-sensing  
area  
circuit  
Stable sensing area  
Proximity Sensor  
4
0 V  
Blue  
Sensing  
object  
Note: The load can be connected to either the  
+V or 0 V side.  
Without  
self-  
diagnostic  
output:  
NO  
100 80  
0
(%)  
Rated  
sensing  
distance  
Polarity: None  
ON  
Setting indicator  
(green)  
4
OFF  
ON  
Load  
+V  
(0 V)  
Operation  
indicator (red)  
Prox-  
imity  
Sensor  
main  
circuit  
OFF  
ON  
Control output  
OFF  
E2E-X@D1-M1J-T  
3
0 V  
(+V)  
Note 1. The load can be connected to either the +V or  
0 V side.  
2. The E2E-X@D1-M1J-T has no polarity.  
Therefore, terminals 3 and 4 have no polarity.  
Non-sensing  
area  
Sensing area  
Proximity Sensor  
1
Load  
Brown  
Sensing  
object  
+V  
Prox-  
imity  
Sensor  
main  
circuit  
2
Without  
E2E-X@D2-N  
self-  
100  
0
(%)  
E2E-X@D2-M1G  
diagnostic  
E2E-X@D2-(M1TGJ)-U  
output:  
Rated  
E2E-X@D2-M3G  
NC  
sensing  
distance  
0 V  
Blue  
ON  
OFF  
Note: The load can be connected to either the +V  
or 0 V side.  
Operation  
indicator (red)  
ON  
Control output  
OFF  
Unstable  
Non-sensing sensing  
Set position  
area  
area  
Stable sensing area  
Proximity Sensor  
Sensing  
object  
Brown (4)  
Load  
+V  
100 80  
0
(%)  
Load  
Rated  
sensing  
distance  
Prox-  
+V  
Orange (2)  
imity  
ON  
With self-  
diagnostic E2E-X@D1S  
Sensor  
main  
circuit  
(diagnostic  
output)  
OFF Setting indicator  
(green)  
ON  
output:  
NO  
E2E-X@D1S-M1  
Blue (3)  
OFF Operation  
indicator (red)  
ON  
0
OFF  
ON  
Control output  
Note: Connect both the loads to the +V side of  
the control output and diagnostic output.  
Diagnostic output*  
OFF  
* The diagnostic output is ON when there is a coil  
burnout or the sensing object is located in the  
unstable sensing area for 0.3 s or longer.  
21  
E2E  
DC 3-Wire Models  
Output  
specifica-  
tions  
Operation  
mode  
Model  
Timing Chart  
Output circuit  
Sensing  
object  
Present  
Not present  
ON  
1
Operation  
indicator (red)  
+V  
Brown  
100 Ω  
OFF  
ON  
Control output  
(between brown  
and black leads)  
NO  
Load  
Constant  
current*  
Proximity  
Sensor  
main  
OFF  
High  
Low  
4
2
Output voltage  
(between black  
and blue leads)  
Black  
circuit  
Tr  
E2E-X@E@  
NPN output E2E-X@E@-M1  
E2E-X@E@-M3  
3
0 V  
Present  
Sensing object  
Blue  
Not present  
*Constant current output is 1.5 to 3 mA.  
Note: For Connector Models, the  
Operation indicator  
ON  
OFF  
ON  
(red)  
NC  
connection between pins 1, 4 and 3  
uses an NO contact, and the  
connection between pins 1, 2 and 3  
uses an NC contact.  
Control output  
(between brown and  
black leads)  
OFF  
High  
Low  
Output voltage  
(between black and  
blue leads)  
Present  
Sensing object  
1
Not present  
Brown  
Operation indicator  
(red)  
+V  
ON  
OFF  
ON  
NO  
Control output  
(Between blue and  
black leads)  
Tr  
Proximity  
Sensor  
main  
*
2
4
OFF  
High  
Low  
Output voltage  
(between brown  
and black leads)  
Black  
circuit  
E2E-X@F@  
PNP output E2E-X@F@-M1  
E2E-X@F@-M3  
Load  
3
100 Ω  
Blue  
0 V  
Present  
Sensing object  
Not present  
Operation indicator  
(red)  
*When a transistor is connected  
Note: For Connector Models, the  
ON  
OFF  
ON  
Control output  
(Between blue and  
black leads)  
NC  
connection between pins 1, 4 and 3  
uses an NO contact, and the  
connection between pins 1, 2 and 3  
uses an NC contact.  
OFF  
High  
Low  
Output voltage  
(between brown  
and black leads)  
Present  
Not present  
ON  
Sensing  
object  
Brown  
+V  
Operation  
NO  
NC  
NO  
100 Ω *  
indicator (red)  
OFF  
ON  
Load  
Control output  
Proximity  
Sensor  
main  
NPN open-  
collector  
output  
OFF  
Black  
E2E-C/X@C@  
circuit  
Present  
Not present  
ON  
Sensing  
object  
Blue  
0 V  
Operation  
indicator (red)  
OFF  
ON  
*The E2E-CR6@ does not have 100-Ω resistance.  
Control  
output  
OFF  
Present  
Not present  
ON  
Sensing  
object  
Brown  
+V  
Operation  
indicator (red)  
OFF  
ON  
Proximity  
Sensor  
main  
Control output  
PNP open-  
collector  
output  
OFF  
Black  
E2E-C/X@B@  
circuit  
Present  
Not present  
ON  
Load  
Sensing  
object  
100 Ω *  
Blue  
0 V  
Operation  
NC  
indicator (red)  
OFF  
ON  
*The E2E-CR6@ does not have 100-Ω resistance.  
Control output  
OFF  
22  
E2E  
AC 2-Wire Models  
Operation  
Model  
Timing Chart  
Output circuit  
mode  
Present  
Not present  
ON  
Sensing  
object  
Brown 3 (or 1)  
Load  
Operation  
NO  
OFF  
indicator (red)  
Proximity  
Sensor  
main  
Operate  
Control output  
Reset  
circuit  
E2E-X@Y@  
E2E-X@Y@-M1  
Blue 4 (or 2)  
Present  
Not present  
ON  
Sensing  
object  
Operation  
Note: For Connector Models, the connection  
between pins 3 and 4 uses an NO  
contact, and the connection between  
pins 1 and 2 uses an NC contact.  
NC  
indicator (red)  
OFF  
Operate  
Reset  
Control  
output  
AC/DC 2-Wire Models  
Operation  
Model  
Timing Chart  
Output circuit  
mode  
Unstable  
sensing  
area  
Brown  
Load  
Set position  
Non-sensing  
area  
Stable sensing area  
Proximity Sensor  
Proximity  
Sensor  
main  
Power  
supply  
Sensing  
object  
24 to 240 VDC  
48 to 240 VAC  
circuit  
100 80  
0
(%)  
NO  
E2E-X@T1  
Blue  
Rated  
sensing  
distance  
ON  
Setting indicator  
(green)  
OFF  
ON  
Note: The load can be connected to either the +V or  
0 V side.  
Operation  
indicator (red)  
OFF  
ON  
There is no need to be concerned about the  
polarity (brown/blue) of the Proximity Sensor.  
Control output  
OFF  
23  
E2E  
Sensor I/O Connectors  
Model for Connectors and Pre-wired Connectors: A Connector is not provided with the Sensor. Be sure to order a Connector separately.  
[Refer to Dimensions for the XS2, XS3, and XS5.]  
Connector  
Cable length 2m  
Applicable  
connector  
code  
ApplicableProximity Connection  
Cable length 5m  
Sensor model  
number  
diagram  
No. *2  
Screw  
Appearance *1  
CablConnector  
model number  
CablConnector  
model number  
Straight  
L-shape  
Straight  
L-shape  
XS2F-D421-DA0-A  
XS2F-D422-DA0-A  
XS2F-D421-DC0-A  
XS2F-D422-DC0-A  
XS2F-D421-GA0-A  
XS2F-D422-GA0-A  
XS2F-D421-GC0-A  
XS2F-D422-GC0-A  
A
B
E2E-X@D1-M1G(J)  
1
E2E-X@E1-M1  
E2E-X@F1-M1  
10  
E2E-X@D1-M1J-T  
E2E-X@D1-M1  
E2E-X@D1-M1J-T  
E2E-X@D1-M1  
E2E-X@D2-M1G(J)  
E2E-X@D2-M1J-T  
E2E-X@D2-M1  
E2E-X@D1S-M1  
E2E-X@E2-M1  
E2E-X@F2-M1  
E2E-X@D2-M1G(J)  
E2E-X@D2-M1J-T  
E2E-X@D2-M1  
3
2
3
2
6
8
7
5
Straight  
L-shape  
XS2F-D421-DD0  
XS2F-D422-DD0  
XS2F-D421-GD0  
XS2F-D422-GD0  
C
Straight  
L-shape  
XS2F-D421-D80-A  
XS2F-D422-D80-A  
XS2F-D421-G80-A  
XS2F-D422-G80-A  
11  
D
E
6
8
7
5
M12  
E2E-X@D1S-M1  
E2E-X@E2-M1  
E2E-X@F2-M1  
11  
14  
Straight  
L-shape  
Straight  
XS2F-A421-DB0-A  
XS2F-A422-DB0-A  
XS2F-A421-D90-A  
XS2F-A421-GB0-A  
XS2F-A422-GB0-A  
XS2F-A421-G90-A  
E2E-X@Y1-M1  
F
E2E-X@Y2-M1  
15  
16  
Smartclick Connector,  
Straight  
G
XS5F-D421-D80-A  
XS5F-D421-G80-A  
E2E-X@D1-M1TGJ  
Smartclick Connector,  
Straight  
Oil-resistant  
Reinforced Cables  
E2E-X@D1-M1TGJ-U  
E2E-X@D2-M1TGJ-U  
17  
18  
H
XS5F-D421-D80-P  
XS5F-D421-G80-P  
E2E-X@D1-M3G  
E2E-X@D2-M3G  
4
9
E2E-X@E1-M3  
E2E-X@F1-M3  
E2E-X@E2-M3  
E2E-X@F2-M3  
E2E-X@D1-M3G  
E2E-X@D2-M3G  
E2E-X@E1-M3  
E2E-X@F1-M3  
Straight  
L-shape  
XS3F-M421-402-A  
XS3F-M422-402-A  
XS3F-M421-405-A  
XS3F-M422-405-A  
12  
13  
I
M8  
4
9
12  
13  
E2E-X@E2-M3  
E2E-X@F2-M3  
Note: Refer to Introduction to Sensor I/O Connectors for details and for information on Cable length and Robotics Cables.  
*1. Images of straight and L-shaped connectors.  
M12 Straight  
M8 Straight  
M8 L-shape  
M12 L-shape  
*2. Refer to Connection Diagrams on page 25 for information on Proximity Sensor and I/O Connector connections.  
24  
E2E  
Connections for Sensor I/O Connectors  
Proximity Sensor  
Connection  
diagram No.  
Sensor I/O Connector  
Connections  
Operation  
mode  
model number  
Type  
Model  
1: Straight  
2: L-shape  
E2E  
XS2F  
1
2
3
4
1
2
3
4
DC 2-wire  
Brown (+)  
1
2
3
4
5
6
7
8
9
E2E-X@D1-M1G(J) XS2F-D42@-@A0-A  
(IEC pin wiring)  
D: 2-m cable  
G: 5-m cable  
Blue ()  
1: Straight  
2: L-shape  
E2E  
XS2F  
DC 2-wire  
(previous pin  
wiring)  
1
2
3
4
1
2
3
4
E2E-X@D1-M1  
XS2F-D42@-@D0  
Blue ()  
Brown (+)  
D: 2-m cable  
G: 5-m cable  
1: Straight  
2: L-shape  
E2E  
XS2F  
1
2
3
4
1
2
3
4
DC 2-wire  
(no polarity)  
NO  
E2E-X@D1-M1J-T  
E2E-X@D1-M3G  
E2E-X@D1S-M1  
XS2F-D42@-@D0  
Blue (+) ()  
Brown () (+)  
D: 2-m cable  
G: 5-m cable  
1: Straight  
2: L-shape  
E2E  
XS3F  
*
1
1
2
3
4
Brown (+)  
DC 2-wire  
(M8 connector)  
XS3F-M42@-40@-A  
2
3
4
White (not connected)  
Blue (not connected)  
Black ()  
2: 2-m cable  
5: 5-m cable  
1: Straight  
2: L-shape  
E2E  
XS2F  
*
DC 2-wire  
(diagnostic  
type)  
1
2
3
4
1
2
3
4
Brown (not connected)  
White (diagnostic output) (+)  
Blue (0 V)  
XS2F-D42@-@80-A  
Black (control output) (+)  
D: 2-m cable  
G: 5-m cable  
1: Straight  
2: L-shape  
E2E  
E2E  
E2E  
E2E  
XS2F  
*
*
1
2
3
4
1
2
3
4
Brown (+)  
DC 2-wire  
(IEC pin wiring)  
E2E-X@D2-M1G(J) XS2F-D42@-@80-A  
White ()  
Blue (not connected)  
Black (not connected)  
D: 2-m cable  
G: 5-m cable  
1: Straight  
2: L-shape  
XS2F  
DC 2-wire  
(previous pin  
wiring)  
1
2
3
4
1
2
3
4
Brown (not connected)  
White (+)  
Blue ()  
Black (not connected)  
E2E-X@D2-M1  
XS2F-D42@-@80-A  
D: 2-m cable  
G: 5-m cable  
NC  
1: Straight  
2: L-shape  
XS2F  
*
1
1
2
3
4
Brown (+)()  
White ()(+)  
Blue (not connected)  
Black (not connected)  
DC 2-wire  
(no polarity)  
E2E-X@D2-M1J-T  
E2E-X@D2-M3G  
XS2F-D42@-@80-A  
2
3
4
D: 2-m cable  
G: 5-m cable  
1: Straight  
2: L-shape  
XS3F  
*
1
1
2
3
4
Brown (+)  
White ()  
Blue (not connected)  
Black (not connected)  
DC 2-wire  
(M8 connector)  
2
3
4
XS3F-M42@-40@-A  
2: 2-m cable  
5: 5-m cable  
* Different from Proximity Sensor wire colors.  
25  
E2E  
Proximity Sensor  
Connection  
diagram No.  
Sensor I/O Connector  
model number  
Connections  
Operation  
mode  
Type  
Model  
1: Straight  
2: L-shape  
E2E  
XS2F  
1
2
3
4
1
2
3
4
Brown (+V)  
10  
11  
12  
13  
14  
15  
16  
17  
18  
NO  
NC  
NO  
NC  
NO  
NC  
E2E-X@E/F1-M1  
XS2F-D42@-@C0-A  
Blue (0 V)  
Black (output)  
D: 2-m cable  
G: 5-m cable  
DC 3-wire  
1: Straight  
2: L-shape  
E2E  
XS3F  
1
1
2
3
4
Brown (+V)  
White (not connected)  
Blue (0 V)  
E2E-X@E2/F2-M1 XS2F-D42@-@80-A  
2
3
4
D: 2-m cable  
G: 5-m cable  
Black (output)  
1: Straight  
2: L-shape  
E2E  
XS3F  
1
1
2
3
4
Brown (+V)  
White (not connected)  
Blue (0 V)  
2
3
4
E2E-X@E1/F1-M3  
E2E-X@E2/F2-M3  
E2E-X@Y1-M1  
XS3F-M42@-40@-A  
2: 2-m cable  
5: 5-m cable  
Black (output)  
DC 3-wire  
(M8 connector)  
1: Straight  
2: L-shape  
E2E  
E2E  
E2E  
XS3F  
1
1
2
3
4
Brown (+V)  
White (output)  
Blue (0 V)  
XS3F-M42@-40@-A  
2
3
4
2: 2-m cable  
5: 5-m cable  
Black (not connected)  
1: Straight  
2: L-shape  
XS2F  
1
1
2
3
4
XS2F-A42@-@B0-A  
2
3
4
Brown  
Blue  
D: 2-m cable  
G: 5-m cable  
AC 2-wire  
XS2F  
*
XS2F-A421-@90-A  
1
2
3
4
1
2
3
4
Brown  
White  
E2E-X@Y2-M1  
D: 2-m cable  
G: 5-m cable  
Blue (not connected)  
Black (not connected)  
E2E  
E2E  
E2E  
XS5F  
XS5F-D421-@80-A  
1
1
2
3
4
Brown (+)  
E2E-X@D1-M1TGJ  
2
3
4
White (not connected)  
Blue (not connected)  
Black ()  
D: 2-m cable  
G: 5-m cable  
NO  
XS5F  
XS5F-D421-@80-P  
DC 2-wire  
(Smartclick  
connector)  
1
2
3
4
1
2
3
4
Brown (+)  
E2E-X@D1-  
White (not connected)  
Blue (not connected)  
Black ()  
M1TGJ-U  
D: 2-m cable  
G: 5-m cable  
XS5F  
XS5F-D421-@80-P  
1
2
3
4
1
2
3
4
Brown (+)  
White ()  
Blue (not connected)  
Black (not connected)  
E2E-X@D2-  
NC  
M1TGJ-U  
D: 2-m cable  
G: 5-m cable  
* Different from Proximity Sensor wire colors.  
Refer to Introduction to Sensor I/O Connectors for details.  
26  
E2E  
Safety Precautions  
Refer to Warranty and Limitations of Liability.  
WARNING  
This product is not designed or rated for ensuring  
safety of persons either directly or indirectly.  
Do not use it for such purposes.  
CAUTION  
Do not short the load. Explosion or burning may  
result.  
Do not supply power to the Sensor with no load,  
otherwise Sensor may be damaged.  
Applicable Models  
E2E-CR6@  
E2E-CR8@  
E2E-X1@  
E2E-C1@  
Relationship between Sizes and  
Models  
Model  
Model  
E2E-CR6C/B  
E2E-CR8C@  
E2E-CR8B@  
E2E-X1C@  
Precautions for Correct Use  
Do not use this product under ambient conditions that exceed the  
ratings.  
3 dia.  
4 dia.  
Design  
Shielded  
M5  
Influence of Surrounding Metal  
E2E-X1B@  
E2E-C1C@  
E2E-C1B@  
E2E-X2D@  
When mounting the Sensor within a metal panel, ensure that the  
clearances given in the following table are maintained. Failure to  
maintain these distances may cause deterioration in the performance  
of the Sensor.  
5.4  
dia.  
E2E-X1R5E@  
E2E-X1R5F@  
E2E-X1R5Y@  
E2E-X4MD@  
E2E-X2ME@  
E2E-X2MF@  
E2E-X2MY@  
E2E-X3D@  
E2E-X2E@  
E2E-X2F@  
E2E-X2Y@  
E2E-X3T1  
Shielded  
l
M8  
n
d dia.  
m
D
m
Influence of Surrounding Metal  
Model  
l
Unshielded  
(Unit: mm)  
Item  
l
M8  
M12  
M18  
M30  
0
0
Shielded  
d
8
12  
18  
30  
Shielded  
D
m
n
M12  
4.5  
12  
12  
24  
12  
8
8
18  
15  
40  
15  
20  
40  
20  
27  
22  
70  
22  
40  
70  
40  
45  
30  
90  
30  
70  
90  
DC 2-Wire Models  
E2E-X@D@  
E2E-X8MD@  
E2E-X5ME@  
E2E-X5MF@  
E2E-X5MY@  
E2E-X7D@  
E2E-X5E@  
E2E-X5F@  
E2E-X5Y@  
E2E-X7T1  
l
AC/DC 2-Wire Models  
Unshielded  
Shielded  
E2E-X@T1  
d
Unshielded  
D
m
n
24  
l
0
0
d
8
12  
18  
30  
M18  
Shielded  
DC 3-Wire Models  
E2E-X@E@  
D
m
n
E2E-X14MD@  
E2E-X10ME@  
E2E-X10MF@  
E2E-X10MY@  
E2E-X10D@  
E2E-X10E@  
E2E-X10F@  
E2E-X10Y@  
E2E-X10T1  
E2E-X20MD@  
E2E-X18ME@  
E2E-X18MF@  
E2E-X18MY@  
4.5  
12  
6
8
18  
15  
40  
15  
20  
36  
20  
27  
22  
55  
22  
40  
54  
40  
45  
30  
90  
30  
70  
90  
E2E-X@F@  
Unshielded  
Shielded  
l
AC 2-Wire Models  
E2E-X@Y@  
d
24  
6
Unshielded  
D
m
n
8
24  
Model  
Item  
3 dia.  
4 dia.  
M5  
5.4 dia.  
M30  
l
0
0
d
3
2
4
5
5.4  
DC 3-Wire Models  
Unshielded  
E2E-X@C/B@  
E2E-C@C/B@  
Shielded  
D
m
n
2.4  
3
8
6
27  
E2E  
Mutual Interference  
Mutual Interference  
(Unit: mm)  
When installing Sensors face-to-face or  
side-by-side, ensure that the minimum  
distances given in the following table are  
maintained.  
Model  
Item  
A
M8  
20  
15  
80  
60  
20  
15  
80  
60  
M12  
M18  
M30  
30 (20)  
20 (12)  
120 (60)  
100 (50)  
30 (20)  
20 (12)  
120 (60)  
100 (50)  
50 (30)  
100 (50)  
70 (35)  
DC 2-Wire Models  
Shielded  
E2E-X@D@  
B
35 (18)  
A
200 (100)  
110 (60)  
50 (30)  
300 (100)  
200 (100)  
100 (50)  
70 (35)  
AC/DC 2-Wire Models  
Unshielded  
Shielded  
E2E-X@T1  
B
A
DC 3-Wire Models  
E2E-X@E@/X@F@  
B
35 (18)  
A
A
200 (100)  
110 (60)  
300 (100)  
200 (100)  
AC 2-Wire Models  
Unshielded  
E2E-X@Y@  
B
Model  
Item  
A
3 dia.  
4 dia.  
M5  
5.4 dia.  
B
DC 3-Wire Models  
E2E-X@C/B@  
20  
15  
Shielded  
B
E2E-C@C/B@  
Note: Values in parentheses apply to Sensors operating at different frequencies.  
Loads with Large Surge Currents (E2E-X@T@)  
If a load with a large surge current is connected, such as a relay, lamp, or motor, the surge current may cause the load short-circuit protection  
circuit to operate, resulting in operating errors.  
Mounting  
Tightening Force  
Do not tighten the nut with excessive force.  
A washer must be used with the nut.  
Refer to the following to mount the E2E-CR6, E2E-CR8 and E2E-C1  
Unthreaded Cylindrical Models.  
E2E-CR6  
E2E-CR8, E2E-C1 8 to 21 mm  
9 to 21 mm  
Shielded Models  
Unshielded Models  
Dimpled end of  
set screw (M3)  
(No screws are provided  
with the E2E-CR8 or  
E2E-C1.)  
Part B Part A  
Part B Part A  
Note: 1. The allowable tightening strength depends on the distance from the  
edge of the head, as shown in the following table. (A is the distance  
from the edge of the head. B includes the nut on the head side. If the  
edge of the nut is in part A, the tightening torque for part A applies  
instead.)  
When using a set screw, tighten it to a torque of 0.2 N·m max.  
(E2E-C1: 0.4 N·m max.)  
2. The following strengths assume washers are being used.  
Part A  
Part B  
Model  
Dimension  
Torque  
Torque  
M5  
M8  
1 N·m  
Shielded  
9
3
9 N·m  
12 N·m  
Unshielded  
M12  
M18  
M30  
30 N·m  
70 N·m  
180 N·m  
Connecting a DC 2-Wire Proximity Sensor to a PLC (Programmable Controller)  
Required Conditions  
Connection to a PLC is possible if the specifications of the PLC and the Proximity Sensor satisfy the following  
conditions. (The meanings of the symbols are given at the right.)  
1. The ON voltage of the PLC and the residual voltage of the Proximity Sensor must satisfy the following.  
VON VCCVR  
VON:ON voltage of PLC (14.4 V)  
ION: ON current of PLC (typically 7 mA)  
IOFF: OFF current of PLC (1.3 mA)  
RIN: Input impedance of PLC (3 kΩ)  
VPC: Internal residual voltage of PLC (4 V)  
VR: Output residual voltage of Proximity Sensor  
(3 V)  
Ileak: Leakage current of Proximity Sensor  
(0.8 mA)  
IOUT Control output of Proximity Sensor (3 to  
2. The OFF current of the PLC and the leakage current of the Proximity Sensor must satisfy the following.  
IOFF Ileak  
(If the OFF current is not listed in the PLC’s input specifications, take it to be 1.3 mA.)  
3. The ON current of the PLC and the control output of the Proximity Sensor must satisfy the following.  
IOUT (min.) ION IOUT (max.)  
The ON current of the PLC will vary, however, with the power supply voltage and the input impedance, as  
shown in the following equation.  
ION = (VCC VR VPC)/RIN  
100 mA)  
VCC:Power supply voltage (PLC: 20.4 to 26.4 V)  
Values in parentheses apply to the following PLC  
model and Proximity Sensor model.  
Example  
In this example, the above conditions are checked when the PLC Unit is the C200H-ID212, the Proximity  
Sensor is the E2E-X7D1-N, and the power supply voltage is 24 V.  
1. VON (14.4 V) VCc (20.4 V) VR (3 V) = 17.4 V:OK  
PLC:  
C200H-ID212  
Sensor: E2E-X7D1-N  
2. IOFF (1.3 mA) Ileak (0.8 mA):  
OK  
3. ION = [VCC (20.4 V) VR (3 V) VPLC (4 V)]/RIN (3 kΩ) = Approx. 4.5 mA  
Therefore, IOUT (min.) (3 mA) ION (4.5 mA):  
Connection is thus possible.  
OK  
28  
E2E  
(Unit: mm)  
Dimensions  
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.  
Main Units  
Model Number-Dimensions Drawing Number Lookup Table  
Model  
Shielded  
DC 2-Wire Models  
Model  
DC 3-Wire Models  
Model  
AC 2-Wire Models  
Model  
AC/DC 2-Wire Models  
Model  
No.  
No.  
1
No.  
Model  
No.  
3 dia.  
4 dia.  
M5  
E2E-CR6@  
E2E-CR8@  
2
---  
---  
E2E-X1@  
4
---  
5.4 dia.  
M8  
E2E-C1@  
3
Shielded  
E2E-X2D@  
5
9
E2E-X1R5E@/F@  
E2E-X2E@/F@  
5
E2E-X1R5Y@  
E2E-X2Y@  
7
M12  
M18  
M30  
M8  
E2E-X3D@  
9
11 E2E-X3T1  
13  
14  
16  
Pre-wired Models  
E2E-X7D@  
14 E2E-X5E@/F@  
16 E2E-X10E@/F@  
14 E2E-X5Y@  
16 E2E-X10Y@  
14 E2E-X7T1  
E2E-X10D@  
16 E2E-X10T1  
E2E-X4MD@  
6
E2E-X2ME@/F@  
6
E2E-X2MY@  
8
M12  
M18  
M30  
M8  
E2E-X8MD@  
10 E2E-X5ME@/F@  
15 E2E-X10ME@/F@  
17 E2E-X18ME@/F@  
18 E2E-X1R5E/F@-M1  
20 E2E-X2E/F@-M1  
24 E2E-X5E/F@-M1  
26 E2E-X10E/F@-M1  
19 E2E-X2ME/F@-M1  
21 E2E-X5ME/F@-M1  
25 E2E-X10ME/F@-M1  
27 E2E-X18ME/F@-M1  
28 E2E-X1R5E/F@-M3  
10 E2E-X5MY@  
15 E2E-X10MY@  
17 E2E-X18MY@  
12  
15  
17  
Unshielded  
Shielded  
---  
---  
E2E-X14MD@  
E2E-X20MD@  
E2E-X2D@-M1(G)  
E2E-X3D@-M1(G)  
E2E-X7D@-M1(G)  
E2E-X10D@-M1(G)  
E2E-X4MD@-M1(G)  
E2E-X8MD@-M1(G)  
E2E-X14MD@-M1(G)  
E2E-X20MD@-M1(G)  
E2E-X2D@-M3G  
18  
---  
M12  
M18  
M30  
M8  
20 E2E-X2Y@-M1  
24 E2E-X5Y@-M1  
26 E2E-X10Y@-M1  
22  
24  
26  
Connector  
Models  
(M12)  
19  
---  
M12  
M18  
M30  
21 E2E-X5MY@-M1  
25 E2E-X10MY@-M1  
27 E2E-X18MY@-M1  
28  
23  
25  
27  
Unshielded  
---  
---  
---  
Connector  
Models  
(M8)  
Shielded  
M8  
---  
Unshielded  
E2E-X4MD@-M3G  
29 E2E-X2ME/F@-M3  
29  
M8  
E2E-X2D@-M1(T)GJ(-U) 30  
E2E-X3D@-M1(T)GJ(-U) 31  
E2E-X7D@-M1(T)GJ(-U) 33  
E2E-X10D@-M1(T)GJ(-U) 35  
M12  
M18  
M30  
M12  
Shielded  
---  
---  
Pre-wired  
Connector  
Models  
E2E-X8MD1-M1(T)GJ  
E2E-X14MD1-M1(T)GJ  
E2E-X20MD1-M1(T)GJ  
E2E-X3D1-M1J-T  
32  
34  
36  
31  
33  
35  
Unshielded M18  
M30  
---  
---  
---  
---  
---  
---  
Pre-wired  
Connector  
Models  
M12  
Shielded M18  
M30  
E2E-X7D@-M1J-T  
E2E-X10D@-M1J-T  
(no polarity)  
Note 1. Two clamping nuts and one toothed washer are provided with M8 to M30 Models.  
2. The model numbers of M8 to M30 Pre-wired Models are laser-marked on the milled section and cable section. This does not apply, however, to models that  
end in -U.  
Pre-wired Models (Shielded)  
Diagram 1 E2E-CR6B@/CR6C@  
Diagram 3 E2E-C1B@/C1C@  
25  
0.1  
27  
3
dia.  
5.4 dia.  
17.5  
17  
*
*
Operation indicator (red)  
Operation indicator (red)  
*2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section:  
0.14 mm2, Insulator diameter: 0.9 mm), Standard length: 2 m  
Robotics Cable Models:  
2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section:  
0.15 mm2, Insulator diameter: 1.05 mm), Standard length: 2 m  
The cable can be extended up to 100 m (separate metal conduit).  
*2.4-dia. vinyl-insulated round cable with 3 conductors  
(Conductor cross section: 0.08 mm2, Insulator diameter: 0.7 mm)  
Diagram 2 E2E-CR8B@/CR8C@  
Mounting Hole Dimensions  
4 dia.  
25  
17.5  
*
Operation indicator (red)  
F
*2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section:  
0.14 mm2, Insulator diameter: 0.9 mm), Standard length: 2 m  
Robotics Cable Models:  
2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section:  
0.15 mm2, Insulator diameter: 1.05 mm), Standard length: 2 m  
The cable can be extended up to 100 m (separate metal conduit).  
Dimension  
3 dia.  
4 dia.  
5.4 dia.  
F (mm)  
3.3+0.3 dia. 4.2+0.5 dia. 5.7+0.5 dia.  
0
0
0
29  
E2E  
Pre-wired Models  
(Shielded)  
Mounting Hole Dimensions  
Dimension  
F (mm)  
M5  
M8  
M12  
5.5+0.5 dia. 8.5+0.5 dia. 12.5+0.5 dia.  
0
0
0
F
Diagram 4 E2E-X1B@/X1C@  
Pre-wired Models (Unshielded)  
25  
10 dia.  
17.5  
8
15  
*
Operation indicator (red)  
Two clamping nuts  
Two toothed washers  
4
M5 × 0.5  
*2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross  
section: 0.14 mm2, Insulator diameter: 0.9 mm), Standard length: 2 m  
Robotics Cable Models:  
2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross  
section: 0.15 mm2, Insulator diameter: 1.05 mm), Standard length: 2 m  
The cable can be extended up to 100 m (separate metal conduit).  
Diagram 5 E2E-X2D@  
E2E-X1R5E@/F@  
Diagram 6 E2E-X4MD@  
E2E-X2ME@/F@  
7
30  
30  
7
15 dia.  
15 dia.  
13  
26  
26  
13  
3
8
6
3
8
6.1 dia.  
M8 × 1  
*1  
Indicators *2  
Two clamping nuts  
Toothed washer  
*1  
M8 × 1  
Indicators *2  
Two clamping nuts  
Toothed washer  
*1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:  
1.3 mm), Standard length: 2 m  
*1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:  
1.3 mm), Standard length: 2 m  
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3  
mm), Standard length: 2 m  
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3  
mm), Standard length: 2 m  
Robotics Cable Models:  
4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:  
1.27 mm), Standard length: 2 m  
Robotics Cable Models:  
4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.27  
mm), Standard length: 2 m  
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:  
1.27 mm), Standard length: 2 m  
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.27  
mm), Standard length: 2 m  
Models with Highly Oil-resistant Cables:  
4-dia. polyurethane-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator  
diameter: 1.3 mm), Standard length: 2 m  
The cable can be extended up to 200 m (separate metal conduit).  
*2. D1 Models: Operation indicator (red) and setting indicator (green), D2/E/F Models: Operation indicator (red)  
The cable can be extended up to 200 m (separate metal conduit).  
*2. D1 Models: Operation indicator (red) and setting indicator (green), D2/E/F Models: Operation indicator (red)  
Diagram 8 E2E-X2MY@  
Diagram 7 E2E-X1R5Y@  
7
40  
36  
40  
7
15 dia.  
36  
15 dia.  
13  
3
8
13  
8
6
3
6.1 dia.  
M8 × 1  
*
*
Operation indicator (red)  
Two clamping nuts  
Operation indicator (red)  
Two clamping nuts  
M8 × 1  
4-dia. vinyl-insulated round cable with 2 conductors  
4-dia. vinyl-insulated round cable with 2 conductors  
(Conductor cross section: 0.3 mm2, Insulator diameter:  
1.3 mm), Standard length: 2 m  
The cable can be extended up to 200 m (separate  
metal conduit).  
Toothed  
washer  
Toothed  
washer  
(Conductor cross section: 0.3 mm2, Insulator  
diameter: 1.3 mm), Standard length: 2 m  
The cable can be extended up to 200 m (separate  
metal conduit).  
Diagram 10 E2E-X8MD@  
E2E-X5ME@/F@  
Diagram 9 E2E-X3D@  
E2E-X2E@/F@  
38  
33  
9
38  
9
21 dia.  
21 dia.  
33  
17  
17  
7
4
10  
4
10  
9 dia.  
*1  
*1  
Indicators * 2  
Two clamping nuts  
Toothed washer  
Indicators *2  
Two clamping nuts  
Toothed washer  
M12 × 1  
M12 × 1  
*1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:  
1.3 mm), Standard length: 2 m  
,
*1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2 Insulator diameter:  
1.3 mm), Standard length: 2 m  
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3  
mm), Standard length: 2 m  
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3  
mm), Standard length: 2 m  
Robotics Cable Models:  
Robotics Cable Models:  
4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.27  
mm), Standard length: 2 m  
4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.27  
mm), Standard length: 2 m  
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.27  
mm), Standard length: 2 m  
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.27  
mm), Standard length: 2 m  
Models with Highly Oil-resistant Cables:  
The cable can be extended (separate metal conduit) up to 200 m for the control output and up to 100 m for the  
diagnostic output.  
*2. D1 Models: Operation indicator (red) and setting indicator (green), D2/E/F Models: Operation indicator (red)  
4-dia. polyurethane-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator  
diameter: 1.3 mm), Standard length: 2 m  
The cable can be extended (separate metal conduit) up to 200 m for the control output and up to 100 m for the  
diagnostic output.  
*2. D1 Models: Operation indicator (red) and setting indicator (green), D2/E/F Models: Operation indicator (red)  
30  
E2E  
Diagram 12 E2E-X5MY@  
Diagram 11 E2E-X2Y@  
43  
9
43  
9
21 dia.  
17  
21 dia.  
17  
38  
38  
7
4
10  
4
10  
9 dia.  
*
*
Operation indicator (red)  
Two clamping nuts  
Operation indicator (red)  
Two clamping nuts  
Toothed  
washer  
M12 × 1  
M12 × 1  
4-dia. vinyl-insulated round cable with 2  
4-dia. vinyl-insulated round cable with 2  
Toothed  
washer  
conductors (Conductor cross section: 0.3 mm2,  
Insulator diameter: 1.3 mm), Standard length: 2 m  
The cable can be extended up to 200 m  
(separate metal conduit).  
conductors (Conductor cross section: 0.3 mm2,  
Insulator diameter: 1.3 mm), Standard length: 2 m  
The cable can be extended up to 200 m (separate  
metal conduit).  
Pre-wired Models (Shielded)  
Mounting Hole Dimensions  
Dimension  
F (mm)  
M8  
M12  
M18  
M30  
8.5+0.5 dia. 12.5+0.5 dia. 18.5+0.5 dia. 30.5+0.5 dia.  
0 0 0 0  
F
Diagram 13 E2E-X3T1  
Pre-wired Models (Unshielded)  
60  
9
21 dia.  
17  
55  
4
10  
*1  
Indicators *2  
M12 × 1  
Two clamping nuts  
*1 4-dia. vinyl-insulated round cable with 2  
conductors (Conductor cross section: 0.3 mm2,  
Insulator diameter: 1.3 mm), Standard length: 2 m  
The cable can be extended up to 200 m (separate  
metal conduit).  
Toothed  
washer  
*2 Operation indicator (red), Setting indicator (green)  
Diagram 14 E2E-X7D@/E2E-X5E@/F@  
E2E-X5Y@/E2E-X7T1  
Diagram 15 E2E-X14MD@/E2E-X10ME@/F@  
E2E-X10MY@  
43  
38  
43  
38  
12  
12  
29 dia.  
24  
29 dia.  
24  
4
10  
4
10  
10  
14.8 dia.  
*1  
*1  
Indicators *2  
*1  
Indicators *2  
M18 × 1  
M18 × 1  
Two clamping nuts  
Toothed washer  
Two clamping nuts  
Toothed washer  
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,  
Insulator diameter: 1.9 mm), Standard length: 2 m  
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,  
Insulator diameter: 1.9 mm), Standard length: 2 m  
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,  
Insulator diameter: 1.9 mm), Standard length: 2 m  
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,  
Insulator diameter: 1.9 mm), Standard length: 2 m  
Robotics Cable Models:  
Robotics Cable Models:  
6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,  
Insulator diameter: 1.74 mm), Standard length: 2 m  
6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,  
Insulator diameter: 1.74 mm), Standard length: 2 m  
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,  
Insulator diameter: 1.74 mm), Standard length: 2 m  
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,  
Insulator diameter: 1.74 mm), Standard length: 2 m  
The cable can be extended (separate metal conduit) up to 200 m for the control output  
and up to 100 m for the diagnostic output.  
*2. D1/T Models: Operation indicator (red), Setting indicator (green)  
D2/E/F/Y Models: Operation indicator (red)  
Models with Highly Oil-resistant Cables:  
6-dia. polyurethane-insulated round cable with 2 conductors (Conductor cross section: 0.5  
mm2, Insulator diameter: 1.9 mm), Standard length: 2 m  
The cable can be extended (separate metal conduit) up to 200 m for the control output and  
up to 100 m for the diagnostic output.  
*2. D1/T Models: Operation indicator (red), Setting indicator (green)  
D2/E/F/Y Models: Operation indicator (red)  
31  
E2E  
Diagram 16 E2E-X10D@/E2E-X10E@/F@  
E2E-X10Y@/E2E-X10T1  
Diagram 17 E2E-X20MD@/E2E-X18ME@/F@  
E2E-X18MY@  
48  
43  
48  
43  
12  
12  
42 dia.  
36  
42 dia.  
36  
5
10  
13  
5
10  
26.8 dia.  
*1  
*1  
Indicators *2  
Indicators *2  
M30 × 1.5  
Two clamping nuts  
Toothed washer  
M30 × 1.5  
Two clamping nuts  
Toothed washer  
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,  
Insulator diameter: 1.9 mm), Standard length: 2 m  
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,  
Insulator diameter: 1.9 mm), Standard length: 2 m  
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,  
Insulator diameter: 1.9 mm), Standard length: 2 m  
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,  
Insulator diameter: 1.9 mm), Standard length: 2 m  
Robotics Cable Models:  
Robotics Cable Models:  
6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,  
Insulator diameter: 1.74 mm), Standard length: 2 m  
6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,  
Insulator diameter: 1.74 mm), Standard length: 2 m  
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,  
Insulator diameter: 1.74 mm), Standard length: 2 m  
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,  
Insulator diameter: 1.74 mm), Standard length: 2 m  
Models with Highly Oil-resistant:  
The cable can be extended (separate metal conduit) up to 200 m for the control output  
and up to 100 m for the diagnostic output.  
*2. D1/T Models: Operation indicator (red), Setting indicator (green)  
D2/E/F/Y Models: Operation indicator (red)  
6-dia. polyurethane-insulated round cable with 2 conductors (Conductor cross section:  
0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m  
The cable can be extended (separate metal conduit) up to 200 m for the control output  
and up to 100 m for the diagnostic output.  
*2. D1/T Models: Operation indicator (red), Setting indicator (green)  
D2/E/F/Y Models: Operation indicator (red)  
M8 Connector Models  
(Shielded)  
M8 Connector Models  
(Unshielded)  
Diagram 28 E2E-X2D@-M3G/E2E-X1R5E@-M3/X1RF@-M3  
Diagram 29 E2E-X4MD@-M3G/E2E-X2ME@-M3/X2MF@-M3  
39  
31  
39  
31  
15 dia.  
13  
15 dia.  
13  
26  
26  
8
3
M8 × 1  
M8 × 1  
* D Models:  
8
6
3
* D Models:  
Operation indicator (red),  
Setting indicator (green)  
Operation indicator (red),  
Setting indicator (green)  
6.1 dia.  
M8 × 1  
D2/E/F Models: Operation indicator (red)  
D2/E/F Models: Operation indicator (red)  
M8 × 1  
Indicators*  
Two clamping nuts  
Toothed washer  
Indicators*  
Two clamping nuts  
Toothed washer  
M12 Connector Models  
(Shielded)  
M12 Connector Models  
(Unshielded)  
Diagram 19 E2E-X4MD@-M1(G)  
E2E-X2ME@-M1/E2E-X2MF@-M1  
Diagram 18 E2E-X2D@-M1(G)  
E2E-X1R5E@-M1/E2E-X1R5F@-M1  
43  
43  
30  
26  
30  
26  
15 dia.  
13  
15 dia.  
13  
M12 × 1  
M12 × 1  
8
6
3
8
3
6.1 dia.  
M8 × 1  
Indicators*  
Two clamping nuts  
Toothed washer  
Indicators*  
Two clamping nuts  
Toothed washer  
M8 × 1  
* D1 Models:  
Operation indicator (red),  
Setting indicator (green)  
* D1 Models:  
Operation indicator (red),  
Setting indicator (green)  
D2/E/F Models: Operation indicator (red)  
D2/E/F Models: Operation indicator (red)  
32  
E2E  
Diagram 20 E2E-X3D@-M1(G)  
E2E-X2E@-M1/E2E-X2F@-M1  
Diagram 21 E2E-X8MD@-M1(G)  
E2E-X5ME@-M1/E2E-X5MF@-M1  
48  
48  
21 dia.  
17  
21 dia.  
17  
33  
33  
4
10  
M12 × 1  
4
10  
7
M12 × 1  
9 dia.  
Indicators *  
Two clamping nuts  
Toothed washer  
Indicators*  
Two clamping nuts  
Toothed washer  
M12 × 1  
M12 × 1  
* D1 Models:  
Operation indicator (red),  
Setting indicator (green)  
* D1 Models:  
D2/E/F Models:Operation indicator (red)  
Operation indicator (red), Setting indicator (green)  
D2/E/F Models:Operation indicator (red)  
Diagram 22 E2E-X2Y@-M1  
Diagram 23 E2E-X5MY@-M1  
53  
53  
21 dia.  
17  
21 dia.  
38  
38  
M12 × 1  
4
10  
7
4
10  
17  
M12 × 1  
9 dia.  
Operation indicator (red)  
Two clamping nuts  
Operation indicator (red)  
Two clamping nuts  
Toothed washer  
M12 × 1  
M12 × 1  
Toothed washer  
Diagram 24 E2E-X7D@-M1(G)/E2E-X5E@-M1/X5F@-M1  
E2E-X5Y@-M1  
Diagram 25 E2E-X14MD@-M1(G)/E2E-X10ME@-M1  
X10MF@-M1  
E2E-X10MY@-M1  
53  
53  
29 dia.  
38  
38  
29 dia.  
24  
4
10  
24  
4
10  
M12 × 1  
10  
M12 × 1  
14.8 dia.  
Indicators*  
M18 × 1  
Indicators*  
Two clamping nuts  
Toothed washer  
M18 × 1  
Two clamping nuts  
Toothed washer  
* D1 Models:  
Operation indicator (red), Setting indicator (green)  
D2/E/Y Models: Operation indicator (red)  
* D1 Models:  
Operation indicator (red), Setting indicator (green)  
D2/E/Y Models: Operation indicator (red)  
Diagram 27 E2E-X20MD@-M1(G)/E2E-X18ME@-M1/  
X18MF@-M1  
Diagram 26 E2E-X10D@-M1(G)/E2E-X10E@-M1/X10F@-M1  
E2E-X10Y@-M1  
E2E-X18MY@-M1  
58  
42 dia.  
36  
58  
43  
42 dia.  
43  
5
10  
13  
5
10  
36  
26.8 dia.  
M12 × 1  
Indicators*  
M12 × 1  
Indicators*  
M30 × 1.5  
Two clamping nuts  
Toothed washer  
M30 × 1.5  
Two clamping nuts  
Toothed washer  
Operation indicator (red), Setting indicator (green)  
* D1 Models: Operation indicator (red), Setting indicator (green)  
D2/E/Y Models: Operation indicator (red)  
* D1 Models:  
D2/E/Y Models: Operation indicator (red)  
Mounting Hole Dimensions  
Dimensions  
F (mm)  
M8  
M12  
M18  
M30  
8.5+0.5 dia. 12.5+0.5 dia. 18.5+0.5 dia. 30.5+0.5 dia.  
0
0
0
0
F
33  
E2E  
Pre-wired Connector Models (Shielded)  
Mounting Hole Dimensions  
F
Dimension  
M12  
M18  
M30  
F (mm)  
12.5+0.5 dia. 18.5+0.5 dia. 30.5+0.5 dia.  
0
0
0
Diagram 30 E2E-X2D@-M1TGJ-U *3  
30  
26  
7
15 dia.  
13  
E2E-X2D1-M1TGJ  
8
3
*1  
Indicators *2  
Two clamping nuts  
M8 × 1  
M12 × 1  
*1. No U suffix: 4-dia. Vinyl-insulated round cable  
U suffix: 4-dia. Polyurethane insulated round cable,  
Standard length: 300 mm  
Toothed washer  
*2. D1 Models: Operation indicator (red), Setting indicator (green)  
D2 Models: Operation indicator (red)  
*3. The connectors for M1TGJ models are XS5 Smartclick connectors.  
Diagram 31 E2E-X3D@-M1GJ  
E2E-X3D1-M1J-T  
38  
33  
9
21 dia.  
17  
4
10  
E2E-X3D@-M1TGJ-U *3  
E2E-X3D1-M1TGJ  
*1  
Indicators *2  
M12 × 1  
M12 × 1  
Two clamping nuts *1. No U suffix: 4-dia. Vinyl-insulated round cable  
U suffix: 4-dia. Polyurethane insulated round cable,  
Standard length: 300 mm  
Toothed washer  
*2. D1 Models: Operation indicator (red), Setting indicator (green)  
D2 Models: Operation indicator (red)  
*3. The connectors for M1TGJ models are XS5 Smartclick connectors.  
43  
38  
12  
Diagram 33 E2E-X7D@-M1GJ  
E2E-X7D@-M1J-T  
29 dia.  
24  
4
10  
E2E-X7D@-M1TGJ-U *3  
E2E-X7D1-M1TGJ  
*1  
M12 × 1  
Indicators *2  
Two clamping nuts  
M18 × 1  
*1. No U suffix: 6-dia. Vinyl-insulated round cable  
U suffix: 6-dia. Polyurethane insulated round cable,  
Standard length: 300 mm  
Toothed washer  
*2. D1 Models: Operation indicator (red), Setting indicator (green)  
D2 Models: Operation indicator (red)  
*3. The connectors for M1TGJ models are XS5 Smartclick connectors.  
Diagram 35 E2E-X10D@-M1GJ  
E2E-X10D@-M1J-T  
48  
12  
42 dia.  
43  
36  
5
10  
E2E-X10D@-M1TGJ-U *3  
E2E-X10D1-M1TGJ  
*1  
M12 × 1  
Indicators *2  
*1. No U suffix: 6-dia. Vinyl-insulated round cable  
U suffix: 6-dia. Polyurethane insulated round cable,  
Standard length: 300 mm  
*2. D1 Models: Operation indicator (red), Setting indicator (green)  
D2 Models: Operation indicator (red)  
M30 × 1.5  
Two clamping nuts  
Toothed washer  
*3. The connectors for M1TGJ models are XS5 Smartclick connectors.  
Pre-wired Connector Models (Unshielded)  
38  
33  
9
Diagram 32 E2E-X8MD1-M1GJ  
E2E-X8MD1-M1TGJ  
21 dia.  
17  
7
4
10  
9 dia.  
*1  
Indicators *2  
Two clamping nuts  
Toothed washer  
M12 × 1  
*1. 4-dia. vinyl-insulated round cable,  
Standard length: 300 mm  
*2. Operation indicator (red), Setting  
indicator (green)  
M12 × 1  
34  
E2E  
43  
38  
12  
Diagram 34 E2E-X14MD@-M1GJ  
E2E-X14MD1-M1TGJ  
29 dia.  
24  
4
10  
10  
14.8 dia.  
*1  
M12 × 1  
Indicators*2  
M18 × 1  
*1. 6-dia. vinyl-insulated round cable, Standard  
length: 300 mm  
Two clamping nuts  
Toothed washer  
*2. D1 Models: Operation indicator (red),  
Setting indicator (green)  
D2 Models: Operation indicator (red)  
Diagram 36 E2E-X20MD1-M1GJ  
E2E-X20MD1-M1TGJ  
48  
43  
12  
42 dia.  
36  
13  
5
10  
26.8 dia.  
*1  
M12 × 1  
Indicators*2  
M30 × 1.5  
*1. 6-dia. vinyl-insulated round cable,  
Two clamping nuts  
Toothed washer  
Standard length: 300 mm  
*2. Operation indicator (red),  
Setting indicator (green)  
Dimensions for Proximity Sensors with Sensor I/O Connectors  
Dimensions with the XS2F Connected (Unit:mm)  
Shielded Models  
Unshielded Models  
Dimension  
Sensor diameter  
L1  
L2  
Straight Connectors  
Straight Connectors  
M8  
Approx. 75  
Approx. 80  
Approx. 85  
Approx. 85  
Approx. 90  
Approx. 62  
Approx. 67  
Approx. 72  
Approx. 72  
Approx. 77  
DC  
M12*  
AC  
L1  
L1  
L-shape Connectors  
L-shape Connectors  
M18  
M30  
* The overall length of the Sensor is different between AC and DC  
Models for Sensors with diameters of M12. This will change the  
dimension when the I/O Connector is connected.  
Dimensions with the XS3F Connected (Unit:mm)  
Dimension  
Sensor diameter  
L2  
L2  
L1  
L2  
M8  
Approx. 65  
Approx. 54  
Accessories (Order Separately)  
Sensor I/O Connectors  
Refer to Introduction to Sensor I/O Connectors for details.  
Mounting Brackets  
Protective Covers  
Sputter Protective Covers  
Refer to Y92@ for details.  
35  
Read and Understand This Catalog  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or  
comments.  
Warranty and Limitations of Liability  
WARRANTY  
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)  
from date of sale by OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR  
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS  
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER  
WARRANTIES, EXPRESS OR IMPLIED.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS  
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT  
LIABILITY.  
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS  
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT  
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.  
Application Considerations  
SUITABILITY FOR USE  
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's  
application or use of the products.  
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the  
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,  
machine, system, or other application or use.  
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible  
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:  
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.  
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,  
safety equipment, and installations subject to separate industry or government regulations.  
Systems, machines, and equipment that could present a risk to life or property.  
Please know and observe all prohibitions of use applicable to the products.  
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE  
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND  
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
PROGRAMMABLE PRODUCTS  
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.  
Disclaimers  
CHANGE IN SPECIFICATIONS  
Product specifications and accessories may be changed at any time based on improvements and other reasons.  
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.  
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or  
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual  
specifications of purchased products.  
DIMENSIONS AND WEIGHTS  
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.  
PERFORMANCE DATA  
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the  
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON  
Warranty and Limitations of Liability.  
ERRORS AND OMISSIONS  
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,  
typographical, or proofreading errors, or omissions.  
2012.4  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2012 All Right Reserved.  

相关型号:

E2E-X2E1

Cylindrical Proximity Sensor
OMRON

E2E-X2E1-M1

Your Search for Proximity Sensors Starts with the World-leading Performance and Quality of the E2E
OMRON

E2E-X2E1-M1-N

Short Barrel Inductive Prox
OMRON

E2E-X2E1-N

Analog Circuit
OMRON

E2E-X2E2

Cylindrical Proximity Sensor
OMRON

E2E-X2E2-M1

Cylindrical Proximity Sensor
OMRON

E2E-X2F1

Cylindrical Proximity Sensor
OMRON

E2E-X2F1-M1

Cylindrical Proximity Sensor
OMRON

E2E-X2F1-M1-N

Short Barrel Inductive Prox
OMRON

E2E-X2F1-N

Analog Circuit
OMRON

E2E-X2F2

Cylindrical Proximity Sensor
OMRON

E2E-X2F2-M1

Cylindrical Proximity Sensor
OMRON