LMX2485SQ/NOPB [NSC]
IC PLL FREQUENCY SYNTHESIZER, 3000 MHz, PQCC24, 4 X 4 MM, 0.8 MM, PLASTIC, LLP-24, PLL or Frequency Synthesis Circuit;型号: | LMX2485SQ/NOPB |
厂家: | National Semiconductor |
描述: | IC PLL FREQUENCY SYNTHESIZER, 3000 MHz, PQCC24, 4 X 4 MM, 0.8 MM, PLASTIC, LLP-24, PLL or Frequency Synthesis Circuit |
文件: | 总40页 (文件大小:428K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
February 27, 2008
LMX2485/LMX2485E
50 MHz - 3.0 GHz High Performance Delta-Sigma Low
Power Dual PLLatinum™ Frequency Synthesizers with 800
MHz Integer PLL
Satellite and cable TV tuners
■
■
General Description
WLAN Standards
The LMX2485 is a low power, high performance delta-sigma
fractional-N PLL with an auxiliary integer-N PLL. The device
Features
is fabricated using National Semiconductor’s advanced pro-
cess.
Quadruple Modulus Prescalers for Lower Divide Ratios
With delta-sigma architecture, fractional spurs at lower offset
frequencies are pushed to higher frequencies outside the loop
RF PLL: 8/9/12/13 or 16/17/20/21
■
■
IF PLL: 8/9 or 16/17
bandwidth. The ability to push close in spur and phase noise
energy to higher frequencies is a direct function of the mod-
ulator order. Unlike analog compensation, the digital feed-
back technique used in the LMX2485 is highly resistant to
changes in temperature and variations in wafer processing.
The LMX2485 delta-sigma modulator is programmable up to
fourth order, which allows the designer to select the optimum
modulator order to fit the phase noise, spur, and lock time
requirements of the system.
Advanced Delta Sigma Fractional Compensation
12 bit or 22 bit selectable fractional modulus
■
■
Up to 4th order programmable delta-sigma modulator
Features for Improved Lock Times and Programming
Fastlock / Cycle slip reduction
■
■
■
Integrated time-out counter
Serial data for programming the LMX2485 is transferred via
a three line high speed (20 MHz) MICROWIRE interface. The
LMX2485 offers fine frequency resolution, low spurs, fast pro-
gramming speed, and a single word write to change the
frequency. This makes it ideal for direct digital modulation
applications, where the N counter is directly modulated with
information. The LMX2485 is available in a 24 lead
4.0 X 4.0 X 0.8 mm LLP package.
Single word write to change frequencies with Fastlock
Wide Operating Range
LMX2485 RF PLL: 500 MHz to 3.0 GHz
■
■
LMX2485E RF PLL: 50 MHz to 3.0 GHz
Useful Features
Digital lock detect output
■
■
■
■
Hardware and software power-down control
Applications
On-chip crystal reference frequency doubler.
Cellular phones and base stations
CDMA, WCDMA, GSM/GPRS, TDMA, EDGE, PDC
■
RF phase comparison frequency up to 50 MHz
2.5 to 3.6 volt operation with ICC = 5.0 mA at 3.0 V
■
Direct digital modulation applications
■
Functional Block Diagram
20087701
PLLatinum™ is a trademark of National Semiconductor Corporation.
© 2008 National Semiconductor Corporation
200877
www.national.com
Connection Diagram
Top View
24-Pin LLP (SQ)
20087722
Pin Descriptions
Pin #
Pin Name
GND
I/O
Pin Description
0
1
2
3
4
5
6
-
O
-
Ground Substrate. This is on the bottom of the package and must be grounded.
RF PLL charge pump output.
CPoutRF
GND
RF PLL analog ground.
VddRF1
FinRF
FinRF*
LE
-
RF PLL analog power supply.
I
RF PLL high frequency input pin.
I
RF PLL complementary high frequency input pin. Shunt to ground with a 100 pF capacitor.
I
MICROWIRE Load Enable. High impedance CMOS input. Data stored in the shift registers is
loaded into the internal latches when LE goes HIGH
7
8
DATA
CLK
I
I
MICROWIRE Data. High impedance binary serial data input.
MICROWIRE Clock. High impedance CMOS Clock input. Data for the various counters is
clocked into the 24 bit shift register on the rising edge
9
VddRF2
CE
-
I
Power supply for RF PLL digital circuitry.
Chip Enable control pin. Must be pulled high for normal operation.
Power supply for RF PLL circuitry.
Test frequency output / Lock Detect.
IF PLL high frequency input pin.
IF PLL analog power supply.
10
11
12
13
14
15
16
17
18
19
VddRF5
Ftest/LD
FinIF
I
O
I
VddIF1
GND
-
-
IF PLL digital ground.
CPoutIF
VddIF2
OSCout
ENOSC
O
-
IF PLL charge pump output
IF PLL power supply.
O
I
Buffered output of the OSCin signal.
Oscillator enable. When this is set to high, the OSCout pin is enabled regardless of the state
of other pins or register bits.
20
21
22
23
24
OSCin
NC
I
I
Input for TCXO signal.
This pin must be left open.
VddRF3
FLoutRF
VddRF4
-
Power supply for RF PLL digital circuitry.
RF PLL Fastlock Output. Also functions as Programmable TRI-STATE CMOS output.
RF PLL analog power supply.
O
-
www.national.com
2
Absolute Maximum Ratings (Notes 1, 2)
Value
Typ
Parameter
Power Supply Voltage
Symbol
Units
Min
-0.3
-0.3
-65
Max
4.25
VCC
Vi
V
V
Voltage on any pin with GND = 0V
Storage Temperature Range
VCC+0.3
+150
Ts
°C
°C
Lead Temperature (Solder 4 sec.)
TL
+260
Recommended Operating Conditions
Value
Typ
3.0
Parameter
Symbol
Units
Min
2.5
-40
Max
3.6
Power Supply Voltage (Note 1)
Operating Temperature
VCC
TA
V
25
+85
°C
Note 1: “Absolute Maximum Ratings” indicate limits beyond which damage to the device may occur. "Recommended Operating Conditions" indicate conditions
for which the device is intended to be functional, but do not guarantee specific performance limits. For guaranteed specifications and test conditions, see the
Electrical Characteristics. The guaranteed specifications apply only for the test conditions listed. The voltage at all the power supply pins of VddRF1, VddRF2,
VddRF3, VddRF4, VddRF5, VddIF1 and VddIF2 must be the same. VCC will be used to refer to the voltage at these pins and ICC will be used to refer to the sum
of all currents through all these power pins.
Note 2: This Device is a high performance RF integrated circuit with an ESD rating < 2 kV and is ESD sensitive. Handling and assembly of this device should
only be done at ESD-free workstations.
Electrical Characteristics (VCC = 3.0V; -40°C ≤ TA ≤ +85°C unless otherwise specified)
Value
Symbol
Parameter
Conditions
Units
Min
Typ
Max
Icc PARAMETERS
IF PLL OFF
RF PLL ON
Charge Pump TRI-STATE
Power Supply Current,
RF Synthesizer
ICCRF
ICCIF
3.3
1.7
mA
mA
IF PLL ON
RF PLL OFF
Charge Pump TRI-STATE
Power Supply Current, IF
Synthesizer
IF PLL ON
RF PLL ON
Charge Pump TRI-STATE
Power Supply Current,
Entire Synthesizer
ICCTOTAL
ICCPD
5.0
1
mA
µA
CE = ENOSC = 0V
CLK, DATA, LE = 0V
Power Down Current
10
RF SYNTHESIZER PARAMETERS
RF_P = 8
500
500
50
2000
3000
2000
3000
0
LMX2485
Operating
Frequency
(Note 3)
RF_P = 16
fFinRF
MHz
RF_P = 8
LMX2485
E
RF_P = 16
50
500 - 3000 MHz
50 - 500 MHz (LMX2485E only)
-15
-8
pFinRF
Input Sensitivity
dBm
MHz
µA
8
Phase Detector
Frequency
(Note 4)
fCOMP
50
RF_CPG = 0
VCPoutRF = VCC/2
95
RF_CPG = 1
VCPoutRF = VCC/2
RF Charge Pump Source
Current
(Note 5)
190
...
µA
µA
µA
ICPoutRFSRCE
...
RF_CPG = 15
VCPoutRF = VCC/2
1520
3
www.national.com
Value
Typ
Symbol
Parameter
Conditions
Units
Min
Max
RF_CPG = 0
VCPoutRF = VCC/2
-95
µA
RF_CPG = 1
VCPoutRF = VCC/2
RF Charge Pump Sink
Current
(Note 5)
-190
...
µA
µA
µA
ICPoutRFSINK
...
RF_CPG = 15
VCPoutRF = VCC/2
-1520
RF Charge Pump TRI-
STATE Current
Magnitude
ICPoutRFTRI
2
10
nA
0.5 ≤ VCPoutRF ≤ VCC -0.5
RF_CPG > 2
RF_CPG ≤ 2
3
3
10
13
%
%
VCPoutRF = VCC/2
Magnitude of RF CP Sink
| ICPoutRF%MIS |
vs. CP Source Mismatch TA = 25°C
Magnitude of RF CP
Current vs. CP Voltage
0.5 ≤ VCPoutRF ≤ VCC -0.5
| ICPoutRF%V |
| ICPoutRF%T |
2
4
8
%
%
TA = 25°C
Magnitude of RF CP
Current vs. Temperature
VCPoutRF = VCC/2
IF SYNTHESIZER PARAMETERS
fFinIF
Operating Frequency
IF Input Sensitivity
75
800
5
MHz
dBm
pFinIF
-10
Phase Detector
Frequency
fCOMP
10
MHz
mA
IF Charge Pump Source
Current
ICPoutIFSRCE
ICPoutIFSINK
VCPoutIF = VCC/2
VCPoutIF = VCC/2
3.5
IF Charge Pump Sink
Current
-3.5
mA
IF Charge Pump TRI-
STATE Current
Magnitude
ICPoutIFTRI
2
10
nA
0.5 ≤ VCPoutIF ≤ VCC RF -0.5
VCPoutIF = VCC/2
Magnitude of IF CP Sink
| ICPoutIF%MIS |
| ICPoutIF%V |
1
4
4
8
%
%
%
vs. CP Source Mismatch TA = 25°C
Magnitude of IF CP
Current vs. CP Voltage
0.5 ≤ VCPoutIF ≤ VCC -0.5
TA = 25°C
10
Magnitude of IF CP
Current vs. Temperature
| ICPoutIF%TEMP
VCPoutIF = VCC/2
OSCILLATOR PARAMETERS
OSC2X = 0
OSC2X = 1
5
5
110
20
MHz
MHz
Oscillator Operating
Frequency
fOSCin
vOSCin
Oscillator Input
Sensitivity
VCC
100
VP-P
µA
0.5
IOSCin
Oscillator Input Current
-100
SPURS
Spurs in band
(Note 6)
-55
dBc
www.national.com
4
Value
Typ
Symbol
Parameter
Conditions
Units
Min
Max
PHASE NOISE
RF_CPG = 0
RF_CPG = 1
-202
-202
-206
-208
-210
RF Synthesizer
LF1HzRF
Normalized Phase Noise RF_CPG = 3
dBc/Hz
dBc/Hz
Contribution (Note 7)
RF_CPG = 7
RF_CPG = 15
IF Synthesizer
Normalized Phase Noise
Contribution
LF1HzIF
-209
DIGITAL INTERFACE (DATA, CLK, LE, ENOSC, CE, Ftest/LD, FLoutRF)
VIH
VIL
IIH
VCC
0.4
1.0
1.0
High-Level Input Voltage
Low-Level Input Voltage
High-Level Input Current
Low-Level Input Current
1.6
V
V
VIH = VCC
VIL = 0 V
-1.0
-1.0
µA
µA
IIL
High-Level Output
Voltage
VOH
VOL
IOH = -500 µA
IOL = 500 µA
VCC-0.4
V
V
Low-Level Output
Voltage
0.4
MICROWIRE INTERFACE TIMING
Data to Clock Set Up
Time
tCS
See MICROWIRE Input Timing
25
ns
tCH
Data to Clock Hold Time See MICROWIRE Input Timing
Clock Pulse Width High See MICROWIRE Input Timing
8
ns
ns
ns
tCWH
tCWL
25
25
Clock Pulse Width Low
See MICROWIRE Input Timing
Clock to Load Enable Set
Up Time
tES
See MICROWIRE Input Timing
25
25
ns
ns
tEW
Load Enable Pulse Width See MICROWIRE Input Timing
Note 3: A slew rate of at least 100 V/uS is recommended for frequencies below 500 MHz for optimal performance.
Note 4: For Phase Detector Frequencies above 20 MHz, Cycle Slip Reduction (CSR) may be required. Legal divide ratios are also required.
Note 5: Refer to table in Section 2.4.2 RF_CPG -- RF PLL Charge Pump Gain for complete listing of charge pump currents.
Note 6: In order to measure the in-band spur, the fractional word is chosen such that when reduced to lowest terms, the fractional numerator is one. The spur
offset frequency is chosen to be the comparison frequency divided by the reduced fractional denominator. The loop bandwidth must be sufficiently wide to negate
the impact of the loop filter. Measurement conditions are: Spur Offset Frequency = 10 kHz, Loop Bandwidth = 100 kHz, Fraction = 1/2000, Comparison Frequency
= 20 MHz, RF_CPG = 7, DITH = 0, and a 4th Order Modulator (FM = 0). These are relatively consistent over tuning range.
Note 7: Normalized Phase Noise Contribution is defined as: LN(f) = L(f) – 20log(N) – 10log(fCOMP) where L(f) is defined as the single side band phase noise
measured at an offset frequency, f, in a 1 Hz Bandwidth. The offset frequency, f, must be chosen sufficiently smaller than the PLL loop bandwidth, yet large
enough to avoid substantial phase noise contribution from the reference source. Measurement conditions are: Offset Frequency = 11 kHz, Loop Bandwidth = 100
kHz for RF_CPG = 7, Fraction = 1/2000, Comparison Frequency = 20 MHz, FM = 0, DITH = 0.
MICROWIRE INPUT TIMING DIAGRAM
20087775
5
www.national.com
Typical Performance Characteristics : Sensitivity (Note 8)
RF PLL Fin Sensitivity
TA = 25°C, RF_P = 16
20087745
RF PLL Fin Sensitivity
VCC = 3.0 V, RF_P = 16
20087746
www.national.com
6
IF PLL Fin Sensitivity
TA = 25°C, IF_P = 16
20087747
IF PLL Fin Sensitivity
VCC = 3.0 V, IF_P = 16
20087748
7
www.national.com
OSCin Sensitivity
TA = 25°C, OSC_2X = 0
20087749
OSCin Sensitivity
VCC = 3.0 V, OSC_2X = 0
20087756
www.national.com
8
OSCin Sensitivity
TA = 25°C, OSC_2X = 1
20087773
OSCin Sensitivity
VCC = 3.0 V, OSC_2X = 1
20087774
9
www.national.com
Typical Performance Characteristic : FinRF Input Impedance (Note 8)
20087768
FinRF Input Impedance
Frequency (MHz)
50
Real (Ohms)
670
531
452
408
373
337
302
270
241
215
192
172
154
139
127
114
104
96
Imaginary (Ohms)
-276
-247
-209
-212
-222
-231
-237
-239
-236
-231
-221
-218
-209
-200
-192
-184
-175
-168
-160
-153
-147
-134
-123
-113
-103
-94
100
200
300
400
500
600
700
800
900
1000
1100
1200
1300
1400
1500
1600
1700
1800
1900
2000
2200
2400
2600
2800
3000
3200
3400
3600
3800
4000
88
80
74
64
56
50
45
39
37
-86
33
-78
30
-72
28
-69
26
-66
www.national.com
10
Typical Performance Characteristic : FinIF Input Impedance (Note 8)
20087754
FinIF Input Impedance
Frequency (MHz)
Real (Ohms)
583
Imaginary (Ohms)
50
75
-286
-256
-241
-209
-209
-219
-224
-228
-228
-223
-218
-208
530
100
200
300
400
500
600
700
800
900
1000
499
426
384
347
310
276
244
216
192
173
11
www.national.com
Typical Performance Characteristic : OSCin Input Impedance (Note 8)
20087755
Frequency
(MHz)
Powered Up
Powered Down
Real
1730
846
466
351
316
278
261
252
239
234
230
225
219
214
208
207
Imaginary
-3779
-2236
-1196
-863
Magnitude
4157
2391
1284
932
Real
392
155
107
166
182
155
153
154
147
145
140
138
133
133
132
133
Imaginary
-8137
-4487
-2215
-1495
-1144
-912
Magnitude
5
8146
4490
2217
-1504
1158
925
10
20
30
40
-672
742
50
-566
631
60
-481
547
-758
774
70
-425
494
-652
669
80
-388
456
-576
595
90
-358
428
-518
538
100
110
120
130
140
150
-337
407
-471
492
-321
392
-436
458
-309
379
-402
123
-295
364
-374
397
-285
353
-349
373
-279
348
-329
355
www.national.com
12
Typical Performance Characteristics : Currents (Note 8)
Power Supply Current
CE = High
20087759
Power Supply Current
CE = LOW
20087761
13
www.national.com
RF PLL Charge Pump Current
VCC = 3.0 Volts
20087767
IF PLL Charge Pump Current
VCC = 3.0 Volts
20087765
www.national.com
14
Charge Pump Leakage
RF PLL
VCC = 3.0 Volts
20087764
Charge Pump Leakage
IF PLL
VCC = 3.0 Volts
20087763
Note 8: Typical performance characteristics do not imply any sort of guarantee. Guaranteed specifications are in the electrical characteristics section.
15
www.national.com
Bench Test Setups
20087769
Charge Pump Current Measurement Procedure
The above block diagram shows the test procedure for testing
the RF and IF charge pumps. These tests include absolute
current level, mismatch, and leakage measurement. In order
to measure the charge pump currents, a signal is applied to
the high frequency input pins. The reason for this is to guar-
antee that the phase detector gets enough transitions in order
to be able to change states. If no signal is applied, it is possible
that the charge pump current reading will be low due to the
fact that the duty cycle is not 100%. The OSCin Pin is tied to
the supply. The charge pump currents can be measured by
simply programming the phase detector to the necessary po-
larity. For instance, in order to measure the RF charge pump,
a 10 MHz signal is applied to the FinRF pin. The source cur-
rent can be measured by setting the RF PLL phase detector
to a positive polarity, and the sink current can be measured
by setting the phase detector to a negative polarity. The IF
PLL currents can be measured in a similar way. Note that the
magnitude of the RF PLL charge pump current is controlled
by the RF_CPG bit. Once the charge pump currents are
known, the mismatch can be calculated as well. In order to
measure leakage, the charge pump is set to a TRI-STATE
mode by enabling the RF_CPT and IF_CPT bits. The table
below shows a summary of the various charge pump tests.
Current Test
RF Source
RF Sink
RF_CPG
RF_CPP
RF_CPT
IF_CPP
IF_CPT
0 to 15
0
1
0
0
X
X
X
0
X
X
X
0
0
1
0 to 15
RF TRI-STATE
IF Source
X
X
X
X
X
X
X
X
1
X
X
X
IF Sink
1
IF TRI-STATE
X
www.national.com
16
Charge Pump Current Specification Definitions
20087750
I1 = Charge Pump Sink Current at VCPout = Vcc - ΔV
I2 = Charge Pump Sink Current at VCPout = Vcc/2
I3 = Charge Pump Sink Current at VCPout = ΔV
I4 = Charge Pump Source Current at VCPout = Vcc - ΔV
I5 = Charge Pump Source Current at VCPout = Vcc/2
I6 = Charge Pump Source Current at VCPout = ΔV
ΔV = Voltage offset from the positive and negative supply
rails. Defined to be 0.5 volts for this part.
vCPout refers to either VCPoutRF or VCPoutIF
Charge Pump Sink Current vs. Charge Pump Output
Source Current Mismatch
20087752
Charge Pump Output Current Magnitude Variation vs.
Temperature
ICPout refers to either ICPoutRF or ICPoutIF
Charge Pump Output Current Magnitude Variation vs.
Charge Pump Output Voltage
20087753
20087751
17
www.national.com
20087770
Frequency Input Pin DC Blocking Capacitor
Corresponding
Counter
Default Counter Value
MUX Value
OSCin
FinRF
1000 pF
RF_R / 2
RF_N / 2
50
14
15
100 pF// 1000 pF
502 + 2097150 /
4194301
FinIF
100 pF
IF_N / 2
IF_R / 2
534
50
13
12
OSCin
1000 pF
Sensitivity Measurement Procedure
Sensitivity is defined as the power level limits beyond which
the output of the counter being tested is off by 1 Hz or more
of its expected value. It is typically measured over frequency,
voltage, and temperature. In order to test sensitivity, the MUX
[3:0] word is programmed to the appropriate value. The
counter value is then programmed to a fixed value and a fre-
quency counter is set to monitor the frequency of this pin. The
expected frequency at the Ftest/LD pin should be the signal
generator frequency divided by twice the corresponding
counter value. The factor of two comes in because the
LMX2485 has a flip-flop which divides this frequency by two
to make the duty cycle 50% in order to make it easier to read
with the frequency counter. The frequency counter input
impedance should be set to high impedance. In order to per-
form the measurement, the temperature, frequency, and volt-
age is set to a fixed value and the power level of the signal is
varied. Note that the power level at the part is assumed to be
4 dB less than the signal generator power level. This accounts
for 1 dB for cable losses and 3 dB for the pad. The power level
range where the frequency is correct at the Ftest/LD pin to
within 1 Hz accuracy is recorded for the sensitivity limits. The
temperature, frequency, and voltage can be varied in order to
produce a family of sensitivity curves. Since this is an open-
loop test, the charge pump is set to TRI-STATE and the
unused side of the PLL (RF or IF) is powered down when not
being tested. For this part, there are actually four frequency
input pins, although there is only one frequency test pin (Ftest/
LD). The conditions specific to each pin are shown in above
table.
Note that for the RF N counter, a fourth order fractional mod-
ulator is used in 22-bit mode with a fraction of 2097150 /
4194301 is used. The reason for this long fraction is to test
the RF N counter and supporting fractional circuitry as com-
pletely as possible.
www.national.com
18
20087771
Input Impedance Measurement Procedure
The above block diagram shows the test setup used for mea-
suring the input impedance for the LMX2485. The DC block-
ing capacitor used between the input SMA connector and the
pin being measured must be changed to a zero Ohm resistor.
This procedure applies to the FinRF, FinIF, and OSCin pins.
The basic test procedure is to calibrate the network analyzer,
ensure that the part is powered up, and then measure the
input impedance. The network analyzer can be calibrated by
using either calibration standards or by soldering resistors di-
rectly to the evaluation board. An open can be implemented
by putting no resistor, a short can be implemented by solder-
ing a zero ohm resistor as close as possible to the pin being
measured, and a short can be implemented by soldering two
100 ohm resistors in parallel as close as possible to the pin
being measured. Calibration is done with the PLL removed
from the PCB. This requires the use of a clamp down fixture
that may not always be generally available. If no clamp down
fixture is available, then this procedure can be done by cali-
brating up to the point where the DC blocking capacitor usu-
ally is, and then implementing port extensions with the
network analyzer. Zero ohm resistor is added back for the
actual measurement. Once the setup is calibrated, it is nec-
essary to ensure that the PLL is powered up. This can be done
by toggling the power down bits (RF_PD and IF_PD) and ob-
serving that the current consumption indeed increases when
the bit is disabled. Sometimes it may be necessary to apply
a signal to the OSCin pin in order to program the part. If this
is necessary, disconnect the signal once it is established that
the part is powered up. It is useful to know the input
impedance of the PLL for the purposes of debugging RF
problems and designing matching networks. Another use of
knowing this parameter is make the trace width on the PCB
such that the input impedance of this trace matches the real
part of the input impedance of the PLL frequency of operation.
In general, it is good practice to keep trace lengths short and
make designs that are relatively resistant to variations in the
input impedance of the PLL.
19
www.national.com
erences available, such as the one given at the end of the
functional description block.
Functional Description (Note 9)
1.0 GENERAL
1.5 N COUNTERS AND HIGH FREQUENCY INPUT PINS
The LMX2485 consists of integrated N counters, R counters,
and charge pumps. The TCXO, VCO and loop filter are sup-
plied external to the chip. The various blocks are described
below.
The N counter divides the VCO frequency down to the com-
parison frequency. Because prescalers are used, there are
limitations on how small the N value can be. The N counters
are discussed in greater depth in the programming section.
Since the input pins to these counters ( FinRF and FinIF ) are
high frequency, layout considerations are important.
1.1 TCXO, OSCILLATOR BUFFER, AND R COUNTER
The oscillator buffer must be driven single-ended by a signal
source, such as a TCXO. The OSCout pin is included to pro-
vide a buffered output of this input signal and is active when
the OSC_OUT bit is set to one. The ENOSC pin can be also
pulled high to ensure that the OSCout pin is active, regardless
of the status of the registers in the LMX2485.
High Frequency Input Pins, FinRF and FinIF
It is generally recommended that the VCO output go through
a resistive pad and then through a DC blocking capacitor be-
fore it gets to these high frequency input pins. If the trace
length is sufficiently short ( < 1/10th of a wavelength ), then
the pad may not be necessary, but a series resistor of about
39 ohms is still recommended to isolate the PLL from the
VCO. The DC blocking capacitor should be chosen at least to
be 27 pF, depending on frequency. It may turn out that the
frequency is above the self-resonant frequency of the capac-
itor, but since the input impedance of the PLL tends to be
capacitive, it actually is a benefit to exceed the tune frequen-
cy. The pad and the DC blocking capacitor should be placed
as close to the PLL as possible
The R counter divides this TXCO frequency down to the com-
parison frequency.
1.2 PHASE DETECTOR
The maximum phase detector operating frequency for the IF
PLL is straightforward, but it is a little more involved for the
RF PLL since it is fractional. The maximum phase detector
frequency for the LMX2485 RF PLL is 50 MHz. However, this
is not possible in all circumstances due to illegal divide ratios
of the N counter. The crystal reference frequency also limits
the phase detector frequency, although the doubler helps with
this limitation. There are trade-offs in choosing the phase de-
tector frequency. If this frequency is run higher, then phase
noise will be lower, but lock time may be increased due to
cycle slipping and the capacitors in the loop filter may become
rather large.
Complementary High Frequency Pin, FinRF*
These inputs may be used to drive the PLL differentially, but
it is very common to drive the PLL in a single ended fashion.
A shunt capacitor should be placed at the FinRF* pin. The
value of this capacitor should be chosen such that the
impedance, including the ESR of the capacitor, is as close to
an AC short as possible at the operating frequency of the PLL.
100 pF is a typical value, depending on frequency.
1.3 CHARGE PUMP
1.6 POWER PINS, POWER DOWN, AND POWER UP
MODES
For the majority of the time, the charge pump output is high
impedance, and the only current through this pin is the Tri-
State leakage. However, it does put out fast correction pulses
that have a width that is proportional to the phase error pre-
sented at the phase detector.
It is recommended that all of the power pins be filtered with a
series 18 ohm resistor and then placing two capacitors shunt
to ground, thus creating a low pass filter. Although it makes
sense to use large capacitor values in theory, the ESR
( Equivalent Series Resistance ) is greater for larger capaci-
tors. For optimal filtering minimize the sum of the ESR and
theoretical impedance of the capacitor. It is therefore recom-
mended to provide two capacitors of very different sizes for
the best filtering. 1 µF and 100 pF are typical values. The
small capacitor should be placed as close as possible to the
pin.
The charge pump converts the phase error presented at the
phase detector into a correction current. The magnitude of
this current is theoretically constant, but the duty cycle is pro-
portional to the phase error. For the IF PLL, this current is not
programmable, but for the RF PLL it is programmable in 16
steps. Also, the RF PLL allows for a higher charge pump cur-
rent to be used when the PLL is locking in order to reduce the
lock time.
The power down state of the LMX2485 is controlled by many
factors. The one factor that overrides all other factors is the
CE pin. If this pin is low, the part will be powered down. As-
serting a high logic level on this pin is necessary to power up
the chip, however, there are other bits in the programming
registers that can override this and put the PLL back in a
power down state. Provided that the voltage on the CE pin is
high, programming the RF_PD and IF_PD bits to zero guar-
antees that the part will be powered up. Programming either
one of these bits to one will power down the appropriate sec-
tion of the synthesizer, provided that the ATPU bit does not
override this.
1.4 LOOP FILTER
The loop filter design can be rather involved. In addition to the
regular constraints and design parameters, delta-sigma PLLs
have the additional constraint that the order of the loop filter
should be one greater than the order of the delta sigma mod-
ulator. This rule of thumb comes from the requirement that the
loop filter must roll off the delta sigma noise at 20 dB/decade
faster than it rises. However, since the noise can not have
infinite power, it must eventually roll off. If the loop bandwidth
is narrow, this requirement may not be necessary. For the
purposes of discussion in this datasheet, the pole of the loop
filter at 0 Hz is not counted. So a second order filter has 3
components, a 3rd order loop filter has 5 components, and
the 4th order loop filter has 7 components. Although a 5th
order loop filter is theoretically necessary for use with a 4th
order modulator, typically a 4th order filter is used in this case.
The loop filter design, especially for higher orders can be
rather involved, but there are many simulation tools and ref-
www.national.com
20
CE Pin RF_PD
ATPU
PLL State
Bit Enabled +
Write to RF
N Counter
Low
X
X
Powered Down
(Asynchronous)
High
High
High
X
0
1
Yes
No
Powered Up
Powered Up
No
Powered Down
( Asynchronous )
1.7 DIGITAL LOCK DETECT OPERATION
The RF PLL digital lock detect circuitry compares the differ-
ence between the phase of the inputs of the phase detector
to a RC generated delay of ε. To indicate a locked state (Lock
= HIGH) the phase error must be less than the ε RC delay for
5 consecutive reference cycles. Once in lock (Lock = HIGH),
the RC delay is changed to approximately δ. To indicate an
out of lock state (Lock = LOW), the phase error must become
greater δ. The values of ε and δ are dependent on which PLL
is used and are shown in the table below:
PLL
RF
IF
ε
δ
10 ns
20 ns
15 ns
30 ns
When the PLL is in the power down mode and the Ftest/LD
pin is programmed for the lock detect function, it is forced
LOW. The accuracy of this circuit degrades at higher com-
parison frequencies. To compensate for this, the DIV4 word
should be set to one if the comparison frequency exceeds 20
MHz. The function of this word is to divide the comparison
frequency presented to the lock detect circuit by 4. Note that
if the MUX[3:0] word is set such as to view lock detect for both
PLLs, an unlocked (LOW) condition is shown whenever either
one of the PLLs is determined to be out of lock.
20087704
21
www.national.com
1.8 CYCLE SLIP REDUCTION AND FASTLOCK
1.8.1 Using Cycle Slip Reduction (CSR) to Avoid Cycle
Slipping
The LMX2485 offers both cycle slip reduction (CSR) and
Fastlock with timeout counter support. This means that it re-
quires no additional programming overhead to use them. It is
generally recommended that the charge pump current in the
steady state be 8X or less in order to use cycle slip reduction,
and 4X or less in steady state in order to use Fastlock. The
next step is to decide between using Fastlock or CSR. This
determination can be made based on the ratio of the com-
parison frequency ( fCOMP ) to loop bandwidth ( BW ).
Once it is decided that CSR is to be used, the cycle slip re-
duction factor needs to be chosen. The available factors are
1/2, 1/4, and 1/16. In order to preserve the same loop char-
acteristics, it is recommended that the following constraint be
satisfied:
(Fastlock Charge Pump Current) / (Steady State Charge
Pump Current) = CSR
In order to satisfy this constraint, the maximum charge pump
current in steady state is 8X for a CSR of 1/2, 4X for a CSR
of 1/4, and 1X for a CSR of 1/16. Because the PLL phase
noise is better for higher charge pump currents, it makes
sense to choose CSR only as large as necessary to prevent
cycle slipping. Choosing it larger than this will not improve lock
time, and will result in worse phase noise.
Comparison
Frequency
Cycle Slip
Reduction
( CSR )
Fastlock
( fCOMP
)
Noticeable better Likely to provide a
fCOMP ≤ 1.25 MHz
than CSR
benefit, provided
that
Marginally better
than CSR
Consider an example where the desired loop bandwidth in
steady state is 100 kHz and the comparison frequency is 20
MHz. This yields a ratio of 200. Cycle slipping may be present,
but would not be too severe if it was there. If a CSR factor of
1/2 is used, this would reduce the ratio to 100 during frequen-
cy acquisition, which is probably sufficient. A charge pump
current of 8X could be used in steady state, and a factor of
16X could be used during frequency acquisition. This yields
a ratio of 1/2, which is equal to the CSR factor and this satis-
fies the above constraint. In this circumstance, it could also
be decided to just use 16X charge pump current all the time,
since it would probably have better phase noise, and the
degradation in lock time would not be too severe.
1.25 MHz < fCOMP
2 MHz
≤
fCOMP > 100 X BW
fCOMP > 2 MHz
Same or worse
than CSR
Cycle Slip Reduction (CSR)
Cycle slip reduction works by reducing the comparison fre-
quency during frequency acquisition while keeping the same
loop bandwidth, thereby reducing the ratio of the comparison
frequency to the loop bandwidth. In cases where the ratio of
the comparison frequency exceeds about 100 times the loop
bandwidth, cycle slipping can occur and significantly degrade
lock times. The greater this ratio, the greater the benefit of
CSR. This is typically the case of high comparison frequen-
cies. In circumstances where there is not a problem with cycle
slipping, CSR provides no benefit. There is a glitch when CSR
is disengaged, but since CSR should be disengaged long be-
fore the PLL is actually in lock, this glitch is not an issue. A
good rule of thumb for CSR disengagement is to do this at the
peak time of the transient response. Because this time is typ-
ically much sooner than Fastlock should be disengaged, it
does not make sense to use CSR and Fastlock in combina-
tion.
1.8.2 Using Fastlock to Improve Lock Times
20087740
Fastlock
Once it is decided that Fastlock is to be used, the loop band-
width multiplier, K, is needed in order to determine the theo-
retical impact of Fastlock on the loop bandwidth and the
resistor value, R2p, that is switched in parallel during Fast-
lock. This ratio is calculated as follows:
Fastlock works by increasing the loop bandwidth only during
frequency acquisition. In circumstances where the compari-
son frequency is less than or equal to 2 MHz, Fastlock may
provide a benefit beyond what CSR can offer. Since Fastlock
also reduces the ratio of the comparison frequency to the loop
bandwidth, it may provide a significant benefit in cases where
the comparison frequency is above 2 MHz. However, CSR
can usually provide an equal or larger benefit in these cases,
and can be implemented without using an additional resistor.
The reason for this restriction on frequency is that Fastlock
has a glitch when it is disengaged. As the time of engagement
for Fastlock decreases and becomes on the order of the fast
lock time, this glitch grows and limits the benefits of Fastlock.
This effect becomes worse at higher comparison frequencies.
There is always the option of reducing the comparison fre-
quency at the expense of phase noise in order to satisfy this
constraint on comparison frequency. Despite this glitch, there
is still a net improvement in lock time using Fastlock in these
circumstances. When using Fastlock, it is also recommended
that the steady state charge pump state be 4X or less. Also,
Fastlock was originally intended only for second order filters,
so when implementing it with higher order filters, the third and
fourth poles can not be too close in, or it will not be possible
to keep the loop filter well optimized when the higher charge
pump current and Fastlock resistor are engaged.
K = ( Fastlock Charge Pump Current ) / ( Steady State
Charge Pump Current )
Loop
K
R2p Value
Lock Time
Bandwidth
1.00 X
1.41 X
1.73 X
2.00 X
2.83 X
3.00 X
4.00 X
1
2
Open
R2/0.41
R2/0.73
R2
100 %
71 %
58%
50%
35%
33%
25%
3
4
8
R2/1.83
R2/2
9
16
R2/3
The above table shows how to calculate the Fastlock resistor
and theoretical lock time improvement, once the ratio , K, is
known. This all assumes a second order filter (not counting
the pole at 0 Hz). However, it is generally recommended that
the loop filter order be one greater than the order of the delta
sigma modulator, which means that a second order filter is
www.national.com
22
never recommended. In this case, the value for R2p is typi-
cally about 80% of what it would be for a second order filter.
Because the Fastlock disengagement glitch gets larger and it
is harder to keep the loop filter optimized as the K value be-
comes larger, designing for the largest possible value for K
usually, but not always yields the best improvement in lock
time. To get a more accurate estimate requires more simula-
tion tools, or trial and error.
The first step to do is choose FM, for the delta sigma modu-
lator order. It is recommended to start with FM = 3 for a third
order modulator and use strong dithering. In general, there is
a trade-off between primary and sub-fractional spurs. Choos-
ing the highest order modulator (FM = 0 for 4th order) typically
provides the best primary fractional spurs, but the worst sub-
fractional spurs. Choosing the lowest modulator order (FM =
2 for 2nd order), typically gives the worst primary fractional
spurs, but the best sub-fractional spurs. Choosing FM = 3, for
a 3rd order modulator is a compromise.
1.8.3 Capacitor Dielectric Considerations for Lock Time
The LMX2485 has a high fractional modulus and high charge
pump gain for the lowest possible phase noise. One consid-
eration is that the reduced N value and higher charge pump
may cause the capacitors in the loop filter to become larger
in value. For larger capacitor values, it is common to have a
trade-off between capacitor dielectric quality and physical
size. Using film capacitors or NPO/COG capacitors yields the
best possible lock times, where as using X7R or Z5R capac-
itors can increase lock time by 0 – 500%. However, it is a
general tendency that designs that use a higher compare fre-
quency tend to be less sensitive to the effects of capacitor
dielectrics. Although the use of lesser quality dielectric ca-
pacitors may be unavoidable in many circumstances, allow-
ing a larger footprint for the loop filter capacitors, using a lower
charge pump current, and reducing the fractional modulus are
all ways to reduce capacitor values. Capacitor dielectrics
have very little impact on phase noise and spurs.
The second step is to choose DITH, for dithering. Dithering
has a very small impact on primary fractional spurs, but a
much larger impact on sub-fractional spurs. The only problem
is that it can add a few dB of phase noise, or even more if the
loop bandwidth is very wide. Disabling dithering (DITH = 0),
provides the best phase noise, but the sub-fractional spurs
are worst (except when the fractional numerator is 0, and in
this case, they are the best). Choosing strong dithering (DITH
= 2) significantly reduces sub-fractional spurs, if not eliminat-
ing them completely, but adds the most phase noise. Weak
dithering (DITH = 1) is a compromise.
The third step is to tinker with the fractional word. Although
1/10 and 400/4000 are mathematically the same, expressing
fractions with much larger fractional numerators often im-
prove the fractional spurs. Increasing the fractional denomi-
nator only improves spurs to a point. A good practical limit
could be to keep the fractional denominator as large as pos-
sible, but not to exceed 4095, so it is not necessary to use the
extended fractional numerator or denominator.
1.9 FRACTIONAL SPUR AND PHASE NOISE CONTROLS
Control of the fractional spurs is more of an art than an exact
science. The first differentiation that needs to be made is be-
tween primary fractional and sub-fractional spurs. The prima-
ry fractional spurs are those that occur at increments of the
channel spacing only. The sub-fractional spurs are those that
occur at a smaller resolution than the channel spacing, usu-
ally one-half or one-fourth. There are trade-offs between frac-
tional spurs, sub-fractional spurs, and phase noise. The rules
of thumb presented in this section are just that. There will be
exceptions. The bits that impact the fractional spurs are FM
and DITH, and these bits should be set in this order.
This steps can be done in different orders and it might take a
few iterations to find the optimum performance. Special con-
siderations should be taken for lower frequencies that are
below about 100 MHz. In addition squaring up the wave, it is
often helpful to use lowest terms fractions instead of highest
terms fractions. Also, dithering may turn out to not be so use-
ful. All the things are to introduce a methodical way of thinking
about optimizing spurs, not an exact method. There will be
exceptions to all these rules.
Note 9: For more information concerning delta-sigma PLLs, loop filter design, cycle slip reduction, Fastlock, and many other topics, visit wireless.national.com.
Here there is the EasyPLL simulation tool and an online reference called "PLL Performance, Simulation, and Design", by Dean Banerjee.
23
www.national.com
Programming Description
2.0 GENERAL PROGRAMMING INFORMATION
The 24-bit data registers are loaded through a MICROWIRE Interface. These data registers are used to program the R counter,
the N counter, and the internal mode control latches. The data format of a typical 24-bit data register is shown below. The control
bits CTL [3:0] decode the register address. On the rising edge of LE, data stored in the shift register is loaded into one of the
appropriate latches (selected by address bits). Data is shifted in MSB first. Note that it is best to program the N counter last, since
doing so initializes the digital lock detector and Fastlock circuitry. Note that initialize means it resets the counters, but it does NOT
program values into these registers. The exception is when 22-bit is not being used. In this case, it is not necessary to program
the R7 register.
MSB
LSB
DATA [21:0]
CTL [3:0]
2 1
23
4 3
0
2.0.1 Register Location Truth Table
The control bits CTL [3:0] decode the internal register address. The table below shows how the control bits are mapped to the
target control register.
C3
x
C2
x
C1
x
C0
0
DATA Location
R0
R1
R2
R3
R4
R5
R6
R7
0
0
1
1
0
1
0
1
0
1
1
1
1
0
0
1
1
0
1
1
1
1
0
1
1
1
1
1
2.0.2 Control Register Content Map
necessary for the PLL to achieve lock. The last 5 registers are
for features that optimize spur, phase noise, and lock time
performance. The next page shows these registers.
Because the LMX2485 registers are complicated, they are
organized into two groups, basic and advanced. The first four
registers are basic registers that contain critical information
Quick Start Register Map
Although it is highly recommended that the user eventually take advantage of all the modes of the LMX2485, the quick start register
map is shown in order for the user to get the part up and running quickly using only those bits critical for basic functionality. The following
default conditions for this programming state are a third order delta-sigma modulator in 12-bit mode with no dithering and no Fastlock.
RE 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
GIS
TE
R
DATA[19:0] ( Except for the RF_N Register, which is [22:0] )
RF_N[10:0]
C3 C2
C1
1
C0
0
R0
RF_FN[11:0]
R1 RF RF
_P _P
D
RF_R[5:0]
RF_FD[11:0]
0
0
0
1
1
R2 IF_
PD
IF_N[18:0]
0
1
R3
R4
0001
RF_CPG[3:0]
IF_R[11:0]
0
1
1
0
1
0
1
1
0
0
1
0
0
0
0
0
1
1
0
0
0
1
1
1
0
0
0
0
www.national.com
24
Complete Register Map
The complete register map shows all the functionality of all registers, including the last five.
RE 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
GIS
TE
R
DATA[19:0] ( Except for the RF_N Register, which is [22:0] )
RF_N[10:0]
C3 C2 C1 C0
0
R0
RF_FN[11:0]
R1 RF RF
_P _P
D
RF_R[5:0]
RF_FD[11:0]
0
0
1
1
R2 IF_
PD
IF_N[18:0]
0
1
0
1
R3
ACCESS[3:0]
RF_CPG[3:0]
IF_R[11:0]
0
1
1
0
1
0
1
1
R4 AT
PU
0
1
0
0
0
DITH
[1:0]
FM
[1:0]
0
OS OS IF_ RF IF_
MUX
[3:0]
C
C
CP
P
_
CP
P
P
_2X _O
UT
R5
RF_FD[21:12]
RF_CPF[3:0]
RF_FN[21:12]
RF_TOC[13:0]
1
1
1
0
1
1
1
0
1
1
1
1
R6 CSR[1:0]
R7
0
0
0
0
0
0
0
0
0
0
DIV
4
0
1
0
0
1
IF_ RF IF_ RF
RS _R CP _C
T
ST
T
PT
2.1 R0 REGISTER
Note that this register has only one control bit, so the N counter value to be changed with a single write statement to the PLL.
RE 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
GIS
TE
R
DATA[22:0]
C0
0
R0
RF_N[10:0]
RF_FN[11:0]
2.1.1 RF_FN[11:0] -- Fractional Numerator for RF PLL
Refer to section 2.6.1 for a more detailed description of this control word.
2.1.2 RF_N[10:0] -- RF N Counter Value
The RF N counter contains an 8/9/12/13 and a 16/17/20/21 prescaler. The N counter value can be calculated as follows:
N = RF_P·RF_C + 4·RF_B + RF_A
RF_C ≥Max{RF_A, RF_B} , for N-2FM-1 ... N+2FM is a necessary condition. This rule is slightly modified in the case where the
RF_B counter has an unused bit, where this extra bit is used by the delta-sigma modulator for the purposes of modulation. Consult
the tables below for valid operating ranges for each prescaler.
25
www.national.com
Operation with the 8/9/12/13 Prescaler (RF_P=0)
RF_N
RF_N [10:0]
RF_C [6:0]
N values less than 25 are prohibited.
RF_B [1:0]
RF_A [1:0]
<25
25-26
27-30
31
Possible only with a second order delta-sigma engine.
Possible only with a second or third order delta-sigma engine.
0
.
0
.
0
.
0
.
0
.
1
.
1
.
0
0
0
1
.
1
1
...
.
.
1023
>1023
1
1
1
1
1
1
1
1
1
1
N values above 1023 are prohibited.
Operation with the 16/17/20/21 Prescaler (RF_P=1)
RF_N [10:0]
RF_N
RF_C [6:0]
RF_B [1:0]
RF_A [1:0]
<49
49-50
51-54
55
N values less than 49 are prohibited.
Possible only with a second order delta-sigma engine.
Possible with a second or third order delta-sigma engine.
0
.
0
.
0
.
0
.
0
.
1
.
1
.
0
.
1
.
1
.
1
.
...
2039
1
1
1
1
1
1
1
0
1
1
1
2040-20
43
Possible with a second or third order delta-sigma engine.
Possible only with a second order delta-sigma engine.
N values greater than 2045 are prohibited.
2044-20
45
>2045
www.national.com
26
2.2 R1 REGISTER
REGISTER
R1
23
22
21 20 19 18 17 16 15 14 13 12 11 10
DATA[19:0]
9
8
7
6
5
4
3
2
1
0
C3 C2 C1 C0
RF_PD RF_P
RF_R[5:0]
RF_FD[11:0]
0
0
1
1
2.2.1 RF_FD[11:0] -- RF PLL Fractional Denominator
The function of these bits are described in section 2.6.2.
2.2.2 RF_R [5:0] -- RF R Divider Value
The RF R Counter value is determined by this control word. Note that this counter does allow values down to one.
R Value
RF_R[5:0]
1
0
.
0
.
0
.
0
.
0
.
1
...
.
63
1
1
1
1
1
1
2.2.3 RF_P -- RF Prescaler bit
The prescaler used is determined by this bit.
RF_P
Prescaler
8/9/12/13
Maximum Frequency
2000 MHz
0
1
16/17/20/21
3000 MHz
2.2.4 RF_PD -- RF Power Down Control Bit
When this bit is set to 0, the RF PLL operates normally. When it is set to one, the RF PLL is powered down and the RF Charge
pump is set to a TRI-STATE mode. The CE pin and ATPU bit also control power down functions, and will override the RF_PD bit.
The order of precedence is as follows. First, if the CE pin is LOW, then the PLL will be powered down. Provided this is not the
case, the PLL will be powered up if the ATPU bit says to do so, regardless of the state of the RF_PD bit. After the CE pin and the
ATPU bit are considered, then the RF_PD bit then takes control of the power down function for the RF PLL.
27
www.national.com
2.3 R2 REGISTER
REGISTER
R2
23
IF_PD
22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
DATA[19:0]
IF_N[18:0]
C3 C2 C1 C0
0
1
0
1
2.3.1 IF_N[18:0] -- IF N Divider Value
IF_N Counter Programming with the 8/9 Prescaler (IF_P=0)
N
Valu
e
IF_N[18:0]
IF_B
IF_A
≤23
24-5
N values less than or equal to 23 are prohibited because IF_B ≥ 3 is required.
Legal divide ratios in this range are:
5
24-27, 32-36, 40-45, 48-54
56
57
...
0
0
.
0
0
.
0
0
.
0
0
.
0
0
.
0
0
.
0
0
.
0
0
.
0
0
.
0
0
.
0
0
.
0
0
.
1
1
.
1
1
.
1
1
.
0
0
.
0
0
.
0
0
.
0
1
.
2621
43
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
1
1
1
Operation with the 16/17 Prescaler (IF_P=1)
N
Valu
e
IF_B
IF_A
≤47
48-2
N values less than or equal to 47 are prohibited because IF_B ≥ 3 is required.
Legal divide ratios in this range are:
39
48-51, 64-68, 80-85, 96-102, 112-119, 128-136, 144-153, 160-170, 176-187, 192-204, 208-221, 224-238
240
241
...
0
0
.
0
0
.
0
0
.
0
0
.
0
0
.
0
0
.
0
0
.
0
0
.
0
0
.
0
0
.
0
0
.
1
1
.
1
1
.
1
1
.
1
1
.
0
0
.
0
0
.
0
0
.
0
1
.
5242
87
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2.3.4 IF_PD -- IF Power Down Bit
When this bit is set to 0, the IF PLL operates normally. When it is set to 1, the IF PLL powers down and the output of the IF PLL
charge pump is set to a TRI-STATE mode. If the ATPU bit is set and register R0 is written to, the IF_PD will be reset to 0 and the
IF PLL will be powered up. If the CE pin is held low, the IF PLL will be powered down, overriding the IF_PD bit.
www.national.com
28
2.4 R3 REGISTER
REGISTER
R3
23 22 21 20 19 18 17 16 15 14 13 12 11 10
DATA[19:0]
9
8
7
6
5
4
3
2
1
0
C3 C2 C1 C0
ACCESS[3:0]
RF_CPG[3:0]
IF_R[11:0]
0
1
1
1
2.4.1 IF_R[11:0] -- IF R Divider Value
For the IF R divider, the R value is determined by the IF_R[11:0] bits in the R3 register. The minimum value for IF_R is 3.
R Value
IF_R[11:0]
3
...
0
.
0
.
0
.
0
.
0
.
0
.
0
.
0
.
0
.
0
.
1
.
1
.
4095
1
1
1
1
1
1
1
1
1
1
1
1
2.4.2 RF_CPG -- RF PLL Charge Pump Gain
This is used to control the magnitude of the RF PLL charge pump in steady state operation.
RF_CPG
Charge Pump State
Typical RF Charge Pump Current at 3
Volts (µA)
0
1
1X
2X
95
190
2
3X
285
3
4X
380
4
5X
475
5
6X
570
6
7X
665
7
8X
760
8
9X
855
9
10X
11X
12X
13X
14X
15X
16X
950
10
11
12
13
14
15
1045
1140
1235
1330
1425
1520
2.4.3 ACCESS -- Register Access word
It is mandatory that the first 5 registers R0-R4 be programmed. The programming of registers R5-R7 is optional. The ACCESS
[3:0] bits determine which additional registers need to be programmed. Any one of these registers can be individually programmed.
According to the table below, when the state of a register is in default mode, all the bits in that register are forced to a default state
and it is not necessary to program this register. When the register is programmable, it needs to be programmed through the
MICROWIRE. Using this register access technique, the programming required is reduced up to 37%.
ACCESS Bit
ACCESS[0]
ACCESS[1]
ACCESS[2]
ACCESS[3]
Register Location
R3[20]
Register Controlled
Must be set to 1
R3[21]
R5
R6
R7
R3[22]
R3[23]
The default conditions the registers is shown below:
29
www.national.com
Re
gis 23 22 21 20 19 18 17 16 15 14 13 12 11 10
ter
9
8
7
6
5
4
3
2
1
0
Data[19:0]
C3 C2 C1 C0
R4
R5
R6
R7
R4 Must be programmed manually.
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
0
1
1
1
0
1
1
1
1
This corresponds to the following bit settings.
Register
Bit Location
R4[23]
Bit Name
ATPU
Bit Description
Autopowerup
Bit Value
Bit State
Disabled
Strong
0
2
3
0
0
R4[17:16]
R4[15:14]
R4[12]
DITH
Dithering
FM
Modulation Order
Oscillator Doubler
3rd Order
Disabled
Disabled
OSC_2X
R4[11]
OSC_OUT
OSCout Pin Enable
R4
IF Charge Pump
Polarity
R4[10]
R4[9]
IF_CPP
1
1
Positive
Positive
RF Charge Pump
Polarity
RF_CPP
R4[8]
IF_P
MUX
IF PLL Prescaler
Ftest/LD Output
1
0
16/17
R4[7:4]
Disabled
Extended Fractional
Denominator
R5[23:14]
R5[13:4]
R6[23:22]
RF_FD[21:12]
RF_FN[21:12]
CSR
0
0
0
Disabled
Disabled
Disabled
R5
R6
Extended Fractional
Numerator
Cycle Slip
Reduction
Fastlock Charge
Pump Current
R6[21:18]
R6[17:4]
R7[13]
RF_CPF
RF_TOC
DIV4
0
0
0
Disabled
Disabled
RF Timeout Counter
Lock Detect
Adjustment
Disabled (Fcomp ≤
20 MHz)
IF PLL Counter
Reset
R7[7]
R7[6]
IF_RST
0
0
Disabled
Disabled
R7
RF PLL Counter
Reset
RF_RST
R7[5]
R7[4]
IF_CPT
IF PLL Tri-State
RF PLL Tri-State
0
0
Disabled
Disabled
RF_CPT
www.national.com
30
2.5 R4 REGISTER
This register controls the conditions for the RF PLL in Fastlock.
REGISTER
R4
23
22 21 20 19 18 17 16 15 14 13
DATA[19:0]
OSC_ OSC_ IF_ RF_
2X OUT CPP CPP
12
11
10
9
8
7 6 5 4
3
2
1
0
C3 C2 C1 C0
DITH
[1:0]
FM
[1:0]
MUX
[3:0]
ATPU
0
1
0
0
0
0
IF_P
1
0
0
1
2.5.1 MUX[3:0] Frequency Out & Lock Detect MUX
These bits determine the output state of the Ftest/LD pin.
MUX[3:0]
Output Type
Output
Description
0
0
0
0
0
0
0
1
High Impedance
Push-Pull
Disabled
General purpose
output, Logical
“High” State
0
0
1
0
Push-Pull
General purpose
output, Logical
“Low” State
0
0
0
0
0
1
1
1
1
1
1
1
1
0
1
1
1
1
0
0
0
0
1
1
1
1
1
0
0
1
1
0
0
1
1
0
0
1
1
1
0
1
0
1
0
1
0
1
0
1
0
1
Push-Pull
Push-Pull
Push-Pull
Open Drain
Open Drain
Open Drain
Push-Pull
Push-Pull
Push-Pull
Push-Pull
Push-Pull
Push-Pull
Push-Pull
RF & IF Digital Lock
Detect
RF Digital Lock
Detect
IF Digital Lock
Detect
RF & IF Analog Lock
Detect
RF Analog Lock
Detect
IF Analog Lock
Detect
RF & IF Analog Lock
Detect
RF Analog Lock
Detect
IF Analog Lock
Detect
IF R Divider divided
by 2
IF N Divider divided
by 2
RF R Divider divided
by 2
RF N Divider divided
by 2
2.5.2 IF_P -- IF Prescaler
When this bit is set to 0, the 8/9 prescaler is used. Otherwise the 16/17 prescaler is used.
IF_P
IF Prescaler
8/9
Maximum Frequency
0
1
800 MHz
800 MHz
16/17
31
www.national.com
2.5.3 RF_CPP -- RF PLL Charge Pump Polarity
RF_CPP
RF Charge Pump Polarity
Negative
0
1
Positive (Default)
2.5.4 IF_CPP -- IF PLL Charge Pump Polarity
For a positive phase detector polarity, which is normally the case, set this bit to 1. Otherwise set this bit for a negative phase
detector polarity.
IF_CPP
IF Charge Pump Polarity
Negative
0
1
Positive
2.5.5 OSC_OUT Oscillator Output Buffer Enable
OSC_OUT
OSCout Pin
0
1
Disabled (High Impedance)
Buffered output of OSCin pin
2.5.6 OSC2X -- Oscillator Doubler Enable
When this bit is set to 0, the oscillator doubler is disabled and the TCXO frequency presented to the IF R and RF R counters is
equal to that of the input frequency of the OSCin pin. When this bit is set to 1, the TCXO frequency presented to the RF R counter
is doubled. Phase noise added by the doubler is negligible.
OSC2X
Frequency Presented to RF R Counter
Frequency Presented to IF R Counter
0
1
fOSCin
fOSCin
2 x fOSCin
2.5.7 FM[1:0] -- Fractional Mode
Determines the order of the delta-sigma modulator. Higher order delta-sigma modulators reduce the spur levels closer to the carrier
by pushing this noise to higher frequency offsets from the carrier. In general, the order of the loop filter should be at least one
greater than the order of the delta-sigma modulator in order to allow for sufficient roll-off.
FM
0
Function
Fractional PLL mode with a 4th order delta-sigma modulator
1
Disable the delta-sigma modulator. Recommended for test use
only.
2
3
Fractional PLL mode with a 2nd order delta-sigma modulator
Fractional PLL mode with a 3rd order delta-sigma modulator
www.national.com
32
2.5.8 DITH[1:0] -- Dithering Control
Dithering is a technique used to spread out the spur energy. Enabling dithering can reduce the main fractional spurs, but can also
give rise to a family of smaller spurs. Whether dithering helps or hurts is application specific. Enabling the dithering may also
increase the phase noise. In most cases where the fractional numerator is zero, dithering usually degrades performance.
Dithering tends to be most beneficial in applications where there is insufficient filtering of the spurs. This often occurs when the
loop bandwidth is very wide or a higher order delta-sigma modulator is used. Dithering tends not to impact the main fractional spurs
much, but has a much larger impact on the sub-fractional spurs. If it is decided that dithering will be used, best results will be
obtained when the fractional denominator is at least 1000.
DITH
Dithering Mode Used
Disabled
0
1
2
3
Weak Dithering
Strong Dithering
Reserved
2.5.9 ATPU -- PLL Automatic Power Up
When this bit is set to 1, both the RF and IF PLL power up when the R0 register is written to. When the R0 register is written to,
the PD_RF and PD_IF bits are changed to 0 in the PLL registers. The exception to this case is when the CE pin is low. In this case,
the ATPU function is disabled.
33
www.national.com
2.6 R5 REGISTER
REGISTER
R5
23 22 21 20 19 18 17 16 15 14 13 12 11 10
DATA[19:0]
9
8
7
6
5
4
3
2
1
0
C3 C2 C1 C0
RF_FD[21:12]
RF_FN[21:12]
1
0
1
1
2.6.1 Fractional Numerator Determination { RF_FN[21:12], RF_FN[11:0], ACCESS[1] }
In the case that the ACCESS[1] bit is 0, then the part operates in 12-bit fractional mode, and the RF_FN2[21:12] bits become do
not care bits. When the ACCESS[1] bit is set to 1, the part operates in 22-bit mode and the fractional numerator is expanded from
12 to 22-bits.
Fra
ctio
nal
RF_FN[21:12]
RF_FN[11:0]
Nu
( These bits only apply in 22- bit mode)
mer
ator
0
1
0
0
.
0
0
.
0
0
.
0
0
.
0
0
.
0
0
.
0
0
.
0
0
.
0
0
.
0
0
.
0
0
.
0
1
.
In 12- bit mode, these are do not care.
In 22- bit mode, for N <4096,
...
these bits should be all set to 0.
409
5
1
1
1
1
1
1
1
1
1
1
1
1
409
6
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0
...
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
419
430
3
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2.6.2 Fractional Denominator Determination { RF_FD[21:12], RF_FD[11:0], ACCESS[1]}
In the case that the ACCESS[1] bit is 0, then the part is operates in the 12-bit fractional mode, and the RF_FD[21:12] bits become
do not care bits. When the ACCESS[1] is set to 1, the part operates in 22-bit mode and the fractional denominator is expanded
from 12 to 22-bits.
Fra
ctio
nal
Den
omi
nat
or
RF_FD[21:12]
RF_FD[11:0]
( These bits only apply in 22- bit mode)
0
1
In 12- bit mode, these are do not care.
In 22- bit mode, for N <4096,
0
0
.
0
0
.
0
0
.
0
0
.
0
0
.
0
0
.
0
0
.
0
0
.
0
0
.
0
0
.
0
0
.
0
1
.
these bits should be all set to 0.
...
409
5
1
1
1
1
1
1
1
1
1
1
1
1
409
6
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0
...
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
419
430
3
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
www.national.com
34
2.7 R6 REGISTER
REGISTER
R6
23
22
21 20 19 18 17 16 15 14 13 12 11 10
DATA[19:0]
9
8
7
6
5
4
3
2
1
0
C3 C2 C1 C0
CSR[1:0]
RF_CPF[3:0]
RF_TOC[13:0]
1
1
0
1
2.7.1 RF_TOC -- RF Time Out Counter and Control for FLoutRF Pin
The RF_TOC[13:0] word controls the operation of the RF Fastlock circuitry as well as the function of the FLoutRF output pin. When
this word is set to a value between 0 and 3, the RF Fastlock circuitry is disabled and the FLoutRF pin operates as a general purpose
CMOS TRI-STATE I/O. When RF_TOC is set to a value between 4 and 16383, the RF Fastlock mode is enabled and the FLoutRF
pin is utilized as the RF Fastlock output pin. The value programmed into the RF_TOC[13:0] word represents two times the number
of phase detector comparison cycles the RF synthesizer will spend in the Fastlock state.
RF_TOC
Fastlock Mode
Disabled
Fastlock Period [CP events] FLoutRF Pin Functionality
0
1
N/A
N/A
High Impedance
Manual
Logic “0” State.
Forces all Fastlock conditions
2
Disabled
Disabled
Enabled
Enabled
Enabled
Enabled
N/A
N/A
Logic “0” State
Logic “1” State
Fastlock
3
4
4X2 = 8
5X2 = 10
…
5
Fastlock
Fastlock
…
16383
16383X2 = 32766
Fastlock
2.7.2 RF_CPF -- RF PLL Fastlock Charge Pump Current
Specify the charge pump current for the Fastlock operation mode for the RF PLL. Note that the Fastlock charge pump current,
steady state current, and CSR control are all interrelated.
RF_CPF
RF Charge Pump State
Typical RF Charge Pump Current at 3
Volts (µA)
0
1
1X
2X
95
190
2
3X
285
3
4X
380
4
5X
475
5
6X
570
6
7X
665
7
8X
760
8
9X
855
9
10X
11X
12X
13X
14X
15X
16X
950
10
11
12
13
14
15
1045
1140
1235
1330
1425
1520
35
www.national.com
2.7.3 CSR[1:0] -- RF Cycle Slip Reduction
CSR controls the operation of the Cycle Slip Reduction Circuit. This circuit can be used to reduce the occurrence of phase detector
cycle slips. Note that the Fastlock charge pump current, steady state current, and CSR control are all interrelated. Refer to section
1.8 for information on how to use this.
CSR
CSR State
Disabled
Enabled
Enabled
Enabled
Sample Rate Reduction Factor
0
1
2
3
1
1/2
1/4
1/16
www.national.com
36
2.8 R7 REGISTER
RE 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
0
8
1
7
6
5
4
3
2
1
0
GI
ST
ER
Data[19:0]
C3 C2 C1 C0
R7
0
0
0
0
0
0
0
0
0
0
DIV
4
0
1
0
IF_ RF IF_ RF
RS _R CP _C
1
1
1
1
T
ST
T
PT
2.8.1 DIV4 -- RF Digital Lock Detect Divide By 4
Because the digital lock detect function is based on a phase error, it becomes more difficult to detect a locked condition for larger
comparison frequencies. When this bit is enabled, it subdivides the RF PLL comparison frequency (it does not apply to the IF
comparison frequency) presented to the digital lock detect circuitry by 4. This enables this circuitry to work at higher comparison
frequencies. It is recommended that this bit be enabled whenever the comparison frequency exceeds 20 MHz and RF digital lock
detect is being used.
2.8.2 IF_RST -- IF PLL Counter Reset
When this bit is enabled, the IF PLL N and R counters are reset, and the charge pump is put in a Tri-State condition. This feature
should be disabled for normal operation. Note that a counter reset is applied whenever the chip is powered up via software or CE
pin.
IF_RST
0 (Default)
1
IF PLL N and R Counters
Normal Operation
IF PLL Charge Pump
Normal Operation
Tri-State
Counter Reset
2.8.3 RF_RST -- RF PLL Counter Reset
When this bit is enabled, the RF PLL N and R counters are reset and the charge pump is put in a Tri-State condition. This feature
should be disabled for normal operation. This feature should be disabled for normal operation. Note that a counter reset is applied
whenever the chip is powered up via software or CE pin.
RF_RST
0 (Default)
1
RF PLL N and R Counters
Normal Operation
RF PLL Charge Pump
Normal Operation
Tri-State
Counter Reset
2.8.4 RF_TRI -- RF Charge Pump Tri-State
When this bit is enabled, the RF PLL charge pump is put in a Tri-State condition, but the counters are not reset. This feature is
typically disabled for normal operation.
RF_TRI
0 (Default)
1
RF PLL N and R Counters
Normal Operation
RF PLL Charge Pump
Normal Operation
Tri-State
Normal Operation
2.8.5 IF_TRI -- IF Charge Pump Tri-State
When this bit is enabled, the IF PLL charge pump is put in a Tri-State condition, but the counters are not reset. This feature is
typically disabled for normal operation.
IF_TRI
0 (Default)
1
IF PLL N and R Counters
Normal Operation
IF PLL Charge Pump
Normal Operation
Tri-State
Normal Operation
37
www.national.com
www.national.com
38
Physical Dimensions inches (millimeters) unless otherwise noted
Plastic Quad LLP (SQ), Bottom View
Order Number LMX2485SQ or LMX2485ESQ for 1000 Unit Reel
Order Number LMX2485SQX or LMX2485ESQX for 4500 Unit Reel
NS Package Number SQA24A
39
www.national.com
Notes
For more National Semiconductor product information and proven design tools, visit the following Web sites at:
Products
www.national.com/amplifiers
Design Support
Amplifiers
WEBENCH
www.national.com/webench
www.national.com/AU
Audio
www.national.com/audio
www.national.com/timing
www.national.com/adc
Analog University
App Notes
Clock Conditioners
Data Converters
Displays
www.national.com/appnotes
www.national.com/contacts
www.national.com/quality/green
www.national.com/packaging
Distributors
www.national.com/displays
www.national.com/ethernet
www.national.com/interface
www.national.com/lvds
Green Compliance
Packaging
Ethernet
Interface
Quality and Reliability www.national.com/quality
LVDS
Reference Designs
Feedback
www.national.com/refdesigns
www.national.com/feedback
Power Management
Switching Regulators
LDOs
www.national.com/power
www.national.com/switchers
www.national.com/ldo
LED Lighting
PowerWise
www.national.com/led
www.national.com/powerwise
Serial Digital Interface (SDI) www.national.com/sdi
Temperature Sensors
Wireless (PLL/VCO)
www.national.com/tempsensors
www.national.com/wireless
THE CONTENTS OF THIS DOCUMENT ARE PROVIDED IN CONNECTION WITH NATIONAL SEMICONDUCTOR CORPORATION
(“NATIONAL”) PRODUCTS. NATIONAL MAKES NO REPRESENTATIONS OR WARRANTIES WITH RESPECT TO THE ACCURACY
OR COMPLETENESS OF THE CONTENTS OF THIS PUBLICATION AND RESERVES THE RIGHT TO MAKE CHANGES TO
SPECIFICATIONS AND PRODUCT DESCRIPTIONS AT ANY TIME WITHOUT NOTICE. NO LICENSE, WHETHER EXPRESS,
IMPLIED, ARISING BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS
DOCUMENT.
TESTING AND OTHER QUALITY CONTROLS ARE USED TO THE EXTENT NATIONAL DEEMS NECESSARY TO SUPPORT
NATIONAL’S PRODUCT WARRANTY. EXCEPT WHERE MANDATED BY GOVERNMENT REQUIREMENTS, TESTING OF ALL
PARAMETERS OF EACH PRODUCT IS NOT NECESSARILY PERFORMED. NATIONAL ASSUMES NO LIABILITY FOR
APPLICATIONS ASSISTANCE OR BUYER PRODUCT DESIGN. BUYERS ARE RESPONSIBLE FOR THEIR PRODUCTS AND
APPLICATIONS USING NATIONAL COMPONENTS. PRIOR TO USING OR DISTRIBUTING ANY PRODUCTS THAT INCLUDE
NATIONAL COMPONENTS, BUYERS SHOULD PROVIDE ADEQUATE DESIGN, TESTING AND OPERATING SAFEGUARDS.
EXCEPT AS PROVIDED IN NATIONAL’S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, NATIONAL ASSUMES NO
LIABILITY WHATSOEVER, AND NATIONAL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY RELATING TO THE SALE
AND/OR USE OF NATIONAL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR
PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY
RIGHT.
LIFE SUPPORT POLICY
NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR
SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL
COUNSEL OF NATIONAL SEMICONDUCTOR CORPORATION. As used herein:
Life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and
whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected
to result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform
can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness.
National Semiconductor and the National Semiconductor logo are registered trademarks of National Semiconductor Corporation. All other
brand or product names may be trademarks or registered trademarks of their respective holders.
Copyright© 2008 National Semiconductor Corporation
For the most current product information visit us at www.national.com
National Semiconductor
Americas Technical
Support Center
Email:
new.feedback@nsc.com
Tel: 1-800-272-9959
National Semiconductor Europe
Technical Support Center
Email: europe.support@nsc.com
German Tel: +49 (0) 180 5010 771
English Tel: +44 (0) 870 850 4288
National Semiconductor Asia
Pacific Technical Support Center
Email: ap.support@nsc.com
National Semiconductor Japan
Technical Support Center
Email: jpn.feedback@nsc.com
www.national.com
相关型号:
LMX2485SQX
50 MHz - 3.0 GHz High Performance Delta-Sigma Low Power Dual PLLatinum⑩ Frequency Synthesizers with 800 MHz Integer PLL
NSC
LMX2485_0610
50 MHz - 3.0 GHz High Performance Delta-Sigma Low Power Dual PLLatinum⑩ Frequency Synthesizers with 800 MHz Integer PLL
NSC
LMX2485_08
50 MHz - 3.0 GHz High Performance Delta-Sigma Low Power Dual PLLatinum⑩ Frequency Synthesizers with 800MHz Integer PLL
NSC
LMX2486
1.0 GHz - 4.5 GHz High Performance Delta-Sigma Low Power Dual PLLatinum TM Frequency Synthesizers with 3.0 GHz Integer PLL
NSC
LMX2486SQ
IC PLL FREQUENCY SYNTHESIZER, 4500 MHz, PQCC24, 4 X 4 MM, 0.8 MM HEIGHT, PLASTIC, LLP-24, PLL or Frequency Synthesis Circuit
NSC
LMX2487
1.0 GHz - 6.0 GHz High Performance Delta-Sigma Low Power Dual PLLatinum™ Frequency Synthesizers with 3.0 GHz Integer PLL
NSC
LMX2487E
7.5 GHz High Performance Delta-Sigma Low Power Dual PLLatinum⑩ Frequency Synthesizers with 3.0 GHz Integer PLL
NSC
©2020 ICPDF网 联系我们和版权申明