DP7409
Quad Digital Potentiometers
(DP) with 64 Taps and 2-wire Interface
FEATURES
DESCRIPTION
Four linear taper digital potentiometers
64 resistor taps per potentiometer
The DP7409 is four Digital Potentiometers
(DP) integrated with control logic and 16 bytes
of NVRAM memory.
End to end resistance 2.5k, 10k, 50k or
100k
2-wire interface (I2C like)
A separate 6-bit control register (WCR) independently
controls the wiper tap position for each DP.
Associated with each wiper control register are four
6-bit non-volatile memory data registers (DR) used for
storing up to four wiper settings. Writing to the wiper
control register or any of the non-volatile data
registers is via a 2-wire serial bus (I2C-like). On
power-up, the contents of the first data register (DR0)
for each of the four potentiometers is automatically
loaded into its respective wiper control register
(WCR).
Low wiper resistance, typically 80
Four non-volatile wiper settings for each
potentiometer
Recall of saved wiper settings at power-up
2.5 to 6.0 volt operation
Standby current less than 1µA
1,000,000 nonvolatile WRITE cycles
100 year nonvolatile memory data retention
24-lead SOIC and 24-lead TSSOP
Write protection for data register
¯¯¯
The Write Protection (WP) pin protects against
inadvertent programming of the data register.
For Ordering Information details, see page 15.
The DP7409 can be used as a potentiometer or as a
two terminal, variable resistor. It is intended for circuit
level or system level adjustments in a wide variety of
applications.
FUNCTIONAL DIAGRAM
PIN CONFIGURATION
TSSOP (Y)
SOIC (W)
R
H0
R
R
H2
R
H3
H1
V
1
2
3
4
5
6
7
8
9
24
23
22
21
20
1
2
24 NC
SDA
WP
CC
SCL
SDA
2-WIRE BUS
INTERFACE
WIPER CONTROL
REGISTERS
R
W0
R
W1
R
W2
R
W3
A
2
R
R
23
A
L0
L3
1
R
R
R
R
R
A
3
22
21
20
19
18
R
R
W0
H0
H3
L1
WP
R
R
V
4
W0
H0
L0
W3
H1
A
0
A
1
A
2
A
3
NONVOLATILE
DATA
REGISTERS
CONTROL LOGIC
A
2
5
R
0
W1
19
18
17
16
15
14
13
6
NC
GND
NC
WP
CC
NC
SDA
A
3
7
R
L0
R
R
L2
R
L3
L1
A
1
17 SCL
8
R
R
R
R
W2
L3
R
R
R
9
16
15
14
13
R
R
R
H2
H3
W3
L1
L2
R
10
11
12
10
11
12
H1
H2
W2
L2
R
SCL
A
W1
0
A
3
NC
GND
NC
© NIDEC COPAL ELECTRONICS CORP.
Characteristics subject to change without notice
1
Doc. No. MD-2010 Rev. K
DP7409
PIN DESCRIPTIONS
Pin#
(TSSOP) (SOIC)
Pin#
SCL: Serial Clock
The DP7409 serial clock input pin is used to clock all
data transfers into or out of the device.
Name Function
Supply Voltage
19
20
1
2
VCC
RL0
Low Reference Terminal
for Potentiometer 0
SDA: Serial Data
The DP7409 bidirectional serial data pin is used to
transfer data into and out of the device. The SDA pin is
an open drain output and can be wire-Ored with the
other open drain or open collector outputs.
High Reference Terminal
for Potentiometer 0
21
22
3
4
RH0
Wiper Terminal for
Potentiometer 0
RW0
A2
Device Address
23
24
1
5
6
7
8
A0, A1, A2, A3: Device Address Inputs
¯¯¯
WP
Write Protection
These inputs set the device address when addressing
multiple devices. A total of sixteen devices can be
addressed on a single bus. A match in the slave
address must be made with the address input in order
to initiate communication with the DP7409.
Serial Data Input/Output
Device Address
SDA
A1
2
Low Reference Terminal
for Potentiometer 1
3
4
5
9
RL1
RH1
RW1
High Reference Terminal
for Potentiometer 1
RH, RL: Resistor End Points
The four sets of RH and RL pins are equivalent to the
terminal connections on a mechanical potentiometer.
10
11
Wiper Terminal for
Potentiometer 1
RW: Wiper
Ground
6
7
12
13
GND
NC
The four RW pins are equivalent to the wiper terminal of
a mechanical potentiometer.
No Connect
Wiper Terminal for
Potentiometer 2
8
9
14
15
16
RW2
RH2
RL2
¯¯¯
WP: Write Protect Input
High Reference Terminal
for Potentiometer 2
¯¯¯
The WP pin when tied low prevents non-volatile writes
to the data registers (change of wiper control register is
allowed) and when tied high or left floating normal
read/write operations are allowed. See Write Protection
on page 7 for more details.
Low Reference Terminal
for Potentiometer 2
10
Bus Serial Clock
Device Address
No Connect
11
12
13
14
17
18
19
20
SCL
A3
NC
A0
Device Address, LSB
Wiper Terminal for
Potentiometer 3
15
16
21
22
RW3
RH3
High Reference Terminal
for Potentiometer 3
Low Reference Terminal
for Potentiometer 3
17
18
23
24
RL3
NC
No Connect
DEVICE OPERATION
The DP7409 is four resistor arrays integrated with 2-wire serial interface logic, four 6-bit wiper control registers
and sixteen 6-bit, non-volatile memory data registers. Each resistor array contains 63 separate resistive elements
connected in series. The physical ends of each array are equivalent to the fixed terminals of a mechanical
potentiometer (RH and RL). RH and RL are symmetrical and may be interchanged. The tap positions between and
at the ends of the series resistors are connected to the output wiper terminals (RW) by a CMOS transistor switch.
Only one tap point for each potentiometer is connected to its wiper terminal at a time and is determined by the
value of the wiper control register. Data can be read or written to the wiper control registers or the non-volatile
memory data registers via the 2-wire bus. Additional instructions allows data to be transferred between the wiper
control registers and each respective potentiometer's non-volatile data registers. Also, the device can be
instructed to operate in an "increment/decrement" mode.
Doc. No. MD-2010 Rev. K
2
© NIDEC COPAL ELECTRONICS CORP.
Characteristics subject to change without notice
DP7409
ABSOLUTE MAXIMUM RATINGS(1)
Parameters
Ratings
-55 to +125
-65 to +150
-2.0 to +VCC + 2.0
-2.0 to +7.0
1.0
Units
ºC
Temperature Under Bias
Storage Temperature
°C
V
(1) (2)
Voltage on Any Pin with Respect to VSS
VCC with Respect to Ground
V
Package Power Dissipation Capability (TA = 25ºC)
Lead Soldering Temperature (10sec)
Wiper Current
W
300
ºC
12
mA
RECOMMENDED OPERATING CONDITIONS
Parameters
VCC
Ratings
+2.5 to +6
-40 to +85
Units
V
Industrial Temperature
°C
POTENTIOMETER CHARACTERISTICS
Over recommended operating conditions unless otherwise stated.
Min
Typ
100
50
Max
Symbol Parameter
Test Conditions
Units
k
RPOT
RPOT
RPOT
RPOT
Potentiometer Resistance (-00)
Potentiometer Resistance (-50)
Potentiometer Resistance (-10)
Potentiometer Resistance (-2.5)
k
10
k
2.5
k
Potentiometer Resistance
Tolerance
RPOT Matching
20
1
%
%
mW
mA
Power Rating
25°C, each pot
50
IW
RW
Wiper Current
6
Wiper Resistance
Wiper Resistance
Voltage on any RH or RL Pin
Resolution
Absolute Linearity (5)
Relative Linearity (6)
IW = 3mA @ VCC = 3V
IW = 3mA @ VCC = 5V
VSS = 0V
300
150
VCC
RW
80
VTERM
GND
V
1.6
%
LSB (7)
(8)
RW(n)(actual) - R(n)(expected)
1
(8)
RW(n+1) - [RW(n) + LSB
]
0.2 LSB (7)
ppm/ºC
TCRPOT
TCRATIO
Temperature Coefficient of RPOT (4)
Ratiometric Temp. Coefficient (4)
CH/CL/CW Potentiometer Capacitances
fc Frequency Response
300
20
ppm/ºC
pF
MHz
(4)
10/10/25
0.4
(4)
RPOT = 50k
Notes:
(1) Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions outside of those listed in the operational sections of this
specification is not implied. Exposure to any absolute maximum rating for extended periods may affect device performance and reliability.
(2) The minimum DC input voltage is –0.5V. During transitions, inputs may undershoot to –2.0V for periods of less than 20ns. Maximum DC
voltage on output pins is VCC +0.5V, which may overshoot to VCC +2.0V for periods of less than 20ns.
(3) Latch-up protection is provided for stresses up to 100mA on address and data pins from –1V to VCC +1V.
(4) This parameter is tested initially and after a design or process change that affects the parameter.
(5) Absolute linearity is utilized to determine actual wiper voltage versus expected voltage as determined by wiper position when used as a potentiometer.
(6) Relative linearity is utilized to determine the actual change in voltage between two successive tap positions when used as a potentio-
meter. It is a measure of the error in step size.
(7) LSB = RTOT / 63 or (RH - RL) / 63, single pot.
(8) n = 0, 1, 2, ..., 63
© NIDEC COPAL ELECTRONICS CORP.
Characteristics subject to change without notice
3
Doc. No. MD-2010 Rev. K
DP7409
D.C. OPERATING CHARACTERISTICS
Over recommended operating conditions unless otherwise stated.
Symbol Parameter
ICC Power Supply Current
ISB
Test Conditions
Min
Max
Units
mA
µA
µA
µA
V
fSCL = 400kHz
1
Standby Current (VCC = 5.0V)
Input Leakage Current
Output Leakage Current
Input Low Voltage
VIN = GND or VCC, SDA Open
VIN = GND to VCC
1
10
ILI
ILO
VOUT = GND to VCC
10
VIL
VIH
VOL1
-1
VCC x 0.3
Input High Voltage
VCC x 0.7 VCC + 1.0
0.4
V
Output Low Voltage (VCC = 3.0V) IOL = 3 mA
V
CAPACITANCE (1)
TA = 25ºC, f = 1.0MHz, VCC = 5V
Symbol Test
Conditions
Max.
Units
pF
CI/O
CIN
Input/Output Capacitance (SDA)
Input Capacitance (A0, A1, A2, A3, SCL, WP)
VI/O = 0V
VIN = 0V
8
6
¯¯¯
pF
A.C. CHARACTERISTICS
Over recommended operating conditions unless otherwise stated.
Symbol Parameter
Min
Typ
Max
400
50
Units
kHz
ns
fSCL
TI(1)
tAA
Clock Frequency
Noise Suppression Time Constant at SCL, SDA Inputs
SLC Low to SDA Data Out and ACK Out
0.9
µs
Time the bus must be free before a new transmission can
start
(1)
tBUF
1.2
µs
tHD:STA
tLOW
Start Condition Hold Time
Clock Low Period
0.6
1.2
0.6
0.6
0
µs
µs
µs
µs
ns
ns
µs
ns
µs
ns
tHIGH
Clock High Period
tSU:STA
tHD:DAT
tSU:DAT
Start Condition SetupTime (for a Repeated Start Condition)
Data in Hold Time
Data in Setup Time
100
(1)
tR
SDA and SCL Rise Time
SDA and SCL Fall Time
Stop Condition Setup Time
Data Out Hold Time
0.3
(1)
tF
300
tSU:STO
tDH
0.6
50
POWER UP TIMING (1)
Symbol Parameter
Max
Units
ms
tPUR
tPUW
Power-up to Read Operation
Power-up to Write Operation
1
1
ms
Note:
(1) This parameter is tested initially and after a design or process change that affects the parameter.
Doc. No. MD-2010 Rev. K
4
© NIDEC COPAL ELECTRONICS CORP.
Characteristics subject to change without notice
DP7409
WRITE CYCLE LIMITS
Symbol
Parameter
Max
Units
tWR
Write Cycle Time
5
ms
The write cycle is the time from a valid stop condition of a write sequence to the end of the internal program/erase cycle. During the write
cycle, the bus interface circuits are disabled, SDA is allowed to remain high, and the device does not respond to its slave address.
RELIABILITY CHARACTERISTICS
Symbol
Parameter
Reference Test Method
Min
1,000,000
100
Max
Units
Cycles/Byte
Years
V
(1)
NEND
Endurance
MIL-STD-883, Test Method 1033
MIL-STD-883, Test Method 1008
MIL-STD-883, Test Method 3015
JEDEC Standard 17
(1)
TDR
Data Retention
ESD Susceptibility
Latch-Up
(1)
VZAP
2000
(1) (2)
ILTH
100
mA
Figure 1. Bus Timing
t
t
t
R
F
HIGH
t
t
LOW
LOW
SCL
t
t
HD:DAT
SU:STA
t
t
t
HD:STA
SU:DAT
SU:STO
SDA IN
t
BUF
t
t
DH
AA
SDA OUT
Figure 2. Write Cycle Timing
SCL
SDA
8TH BIT
BYTE n
ACK
t
WR
STOP
CONDITION
START
CONDITION
ADDRESS
Figure 3. Start/Stop Timing
SDA
SCL
START CONDITION
STOP CONDITION
Notes:
(1) This parameter is tested initially and after a design or process change that affects the parameter.
(2) PUR and tPUW are delays required from the time VCC is stable until the specified operation can be initiated.
t
© NIDEC COPAL ELECTRONICS CORP.
Characteristics subject to change without notice
5
Doc. No. MD-2010 Rev. K
DP7409
most significant bits of the 8-bit slave address are
fixed as 0101 for the DP7409 (see Figure 5). The
next four significant bits (A3, A2, A1, A0) are the
device address bits and define which device the
Master is accessing. Up to sixteen devices may be
individually addressed by the system. Typically, +5V
and ground are hard-wired to these pins to establish
the device's address.
SERIAL BUS PROTOCOL
The following defines the features of the 2-wire bus
protocol:
(1) Data transfer may be initiated only when the bus
is not busy.
(2) During a data transfer, the data line must remain
stable whenever the clock line is high. Any
changes in the data line while the clock is high will
be interpreted as a START or STOP condition.
After the Master sends a START condition and the
slave address byte, the DP7409 monitors the bus
and responds with an acknowledge (on the SDA line)
when its address matches the transmitted slave
address.
The device controlling the transfer is a master,
typically a processor or controller, and the device
being controlled is the slave. The master will always
initiate data transfers and provide the clock for both
transmit and receive operations. Therefore, the
DP7409 will be considered a slave device in all
applications.
Acknowledge
After a successful data transfer, each receiving device
is required to generate an acknowledge. The
Acknowledging device pulls down the SDA line during
the ninth clock cycle, signaling that it received the 8
bits of data.
START Condition
The START Condition precedes all commands to the
device, and is defined as a HIGH to LOW transition of
SDA when SCL is HIGH. The DP7409 monitors the
SDA and SCL lines and will not respond until this
condition is met.
The DP7409 responds with an acknowledge after
receiving a START condition and its slave address. If
the device has been selected along with a write
operation, it responds with an acknowledge after
receiving each 8-bit byte.
STOP Condition
A LOW to HIGH transition of SDA when SCL is HIGH
determines the STOP condition. All operations must
end with a STOP condition.
When the DP7409 is in a READ mode it transmits 8
bits of data, releases the SDA line, and monitors the
line for an acknowledge. Once it receives this
acknowledge, the DP7409 will continue to transmit
data. If no acknowledge is sent by the Master, the
device terminates data transmission and waits for a
STOP condition.
DEVICE ADDRESSING
The bus Master begins a transmission by sending a
START condition. The Master then sends the address
of the particular slave device it is requesting. The four
Figure 4. Acknowledge Timing
SCL FROM
MASTER
1
8
9
DATA OUTPUT
FROM TRANSMITTER
DATA OUTPUT
FROM RECEIVER
START
ACKNOWLEDGE
Doc. No. MD-2010 Rev. K
6
© NIDEC COPAL ELECTRONICS CORP.
Characteristics subject to change without notice
DP7409
host's write operation, the DP7409 initiates the
internal write cycle. ACK polling can be initiated
immediately. This involves issuing the start condition
followed by the slave address. If the DP7409 is still
busy with the write operation, no ACK will be returned.
If the DP7409 has completed the write operation, an
ACK will be returned and the host can then proceed
with the next instruction operation.
WRITE OPERATIONS
In the Write mode, the Master device sends the
START condition and the slave address information to
the Slave device. After the Slave generates an
acknowledge, the Master sends the instruction byte
that defines the requested operation of DP7409. The
instruction byte consist of a four-bit opcode followed
by two register selection bits and two pot selection
bits. After receiving another acknowledge from the
Slave, the Master device transmits the data to be
written into the selected register. The DP7409
acknowledges once more and the Master generates
the STOP condition, at which time if a non-volatile
data register is being selected, the device begins an
internal programming cycle to non-volatile memory.
While this internal cycle is in progress, the device will
not respond to any request from the Master device.
WRITE PROTECTION
The Write Protection feature allows the user to protect
against inadvertent programming of the non-volatile
¯¯¯
data registers. If the WP pin is tied to LOW, the data
registers are protected and become read only.
¯¯¯
Similarly, the WP pin going low after start but after
start will interrupt non-volatile write to data registers,
¯¯¯
while the WP pin going low after internal write cycle
has started, will have no effect on any write operation.
The DP7409 will accept both slave addresses and
instructions, but the data registers are protected from
programming by the device’s failure to send an
acknowledge after data is received.
Acknowledge Polling
The disabling of the inputs can be used to take
advantage of the typical write cycle time. Once the
stop condition is issued to indicate the end of the
Figure 5. Slave Address Bits
DP7409
0
1
0
1
A3 A2 A1 A0
*
A0, A1, A2 and A3 correspond to pin A0, A1, A2 and A3 of the device.
** A0, A1, A2 and A3 must compare to its corresponding hard wired input pins.
Figure 6. Write Timing
S
SLAVE/DP
ADDRESS
INSTRUCTION
BYTE
T
A
R
T
S
T
BUS ACTIVITY:
MASTER
Register
O
P
Pot/WCR
DR1 WCRDATA
Fixed
Variable
op code
Address
Address
SDA LINE
S
P
A
C
K
A
C
K
A
C
K
© NIDEC COPAL ELECTRONICS CORP.
Characteristics subject to change without notice
7
Doc. No. MD-2010 Rev. K
DP7409
INSTRUCTION AND REGISTER
DESCRIPTION
INSTRUCTION BYTE
SLAVE ADDRESS BYTE
The next byte sent to the DP7409 contains the
instruction and register pointer information. The four
most significant bits used provide the instruction
opcode I [3:0]. The R1 and R0 bits point to one of the
four data registers of each associated potentiometer.
The least two significant bits point to one of four Wiper
Control Registers. The format is shown in Table 2.
The first byte sent to the DP7409 from the master/
processor is called the Slave/DP Address Byte. The
most significant four bits of the Device Type address
are a device type identifier. These bits for the
DP7409 are fixed at 0101[B] (refer to Table 1).
The next four bits, A3 - A0, are the internal slave
address and must match the physical device address
which is defined by the state of the A3 - A0 input pins
for the DP7409 to successfully continue the
command sequence. Only the device which slave
address matches the incoming device address sent by
the master executes the instruction. The A3 - A0
inputs can be actively driven by CMOS input signals
or tied to VCC or VSS.
Data Register Selection
Data Register Selected
R1
0
R0
0
DR0
DR1
DR2
DR3
0
1
1
0
1
1
Table 1. Identification Byte Format
Device Type
Identifier
Slave Address
ID3
0
ID2
1
ID1
0
ID0
A3
A2
A1
A0
(LSB)
1
(MSB)
Table 2. Instruction Byte Format
Instruction
Opcode
Data Register
Selection
WCR/Pot Selection
I3
(MSB)
I2
I1
I0
R1
R0
P1
P0
(LSB)
Doc. No. MD-2010 Rev. K
8
© NIDEC COPAL ELECTRONICS CORP.
Characteristics subject to change without notice
DP7409
Registers is a non-volatile operation and will take a
maximum of 5ms.
WIPER CONTROL AND DATA REGISTERS
Wiper Control Register (WCR)
If the application does not require storage of multiple
settings for the potentiometer, the Data Registers can
be used as standard memory locations for system
parameters or user preference data.
The DP7409 contains four 6-bit Wiper Control
Registers, one for each potentiometer. The Wiper
Control Register output is decoded to select one of 64
switches along its resistor array. The contents of the
WCR can be altered in four ways: it may be written by
the host via Write Wiper Control Register instruction; it
may be written by transferring the contents of one of
four associated Data Registers via the XFR Data
Register instruction, it can be modified one step at a
time by the Increment/decrement instruction (see
Instruction section for more details). Finally, it is
loaded with the content of its data register zero (DR0)
upon power-up.
INSTRUCTIONS
Four of the nine instructions are three bytes in length.
These instructions are:
— Read Wiper Control Register – read the current
wiper position of the selected potentiometer in the
WCR
— Write Wiper Control Register – change current
wiper position in the WCR of the selected
potentiometer
The Wiper Control Register is a volatile register that
loses its contents when the DP7409 is powered-
down. Although the register is automatically loaded
with the value in DR0 upon power-up, this may be
different from the value present at power-down.
— Read Data Register – read the contents of the
selected Data Register
— Write Data Register – write a new value to the
selected Data Register
The basic sequence of the three byte instructions is
illustrated in Figure 8. These three-byte instructions
exchange data between the WCR and one of the Data
Registers. The WCR controls the position of the wiper.
The response of the wiper to this action will be de-
layed by tWRL. A transfer from the WCR (current wiper
Data Registers (DR)
Each potentiometer has four 6-bit non-volatile Data
Registers. These can be read or written directly by the
host. Data can also be transferred between any of the
four Data Registers and the associated Wiper Control
Register. Any data changes in one of the Data
Table 3. Instruction Set
Note: 1/0 = data is one or zero
Instruction Set
Instruction
Operation
I3 I2 I1 I0 R1 R0
WCR1/ P1
WCR0/ P0
1
0
0
1
0
0
1/0
1/0
Read Wiper Control
Register
Read the contents of the Wiper Control
Register pointed to by P1-P0
1
0
1
0
0
0
1/0
1/0
Write Wiper Control
Register
Write new value to the Wiper Control
Register pointed to by P1-P0
1
1
0
1
1
0
1
0
1/0 1/0
1/0 1/0
1/0
1/0
1/0
1/0
Read the contents of the Data Register
pointed to by P1-P0 and R1-R0
Write new value to the Data Register
pointed to by P1-P0 and R1-R0
Read Data Register
Write Data Register
Transfer the contents of the Data Register
pointed to by P1-P0 and R1-R0 to its
associated Wiper Control Register
XFR Data Register to
Wiper Control Register
1
1
1
1
0
1
1
0
1/0 1/0
1/0 1/0
1/0
1/0
1/0
1/0
XFR Wiper Control
Register to Data
Register
Transfer the contents of the Wiper Control
Register pointed to by P1-P0 to the Data
Register pointed to by R1-R0
Gang XFR Data
Registers to Wiper
Control Registers
Transfer the contents of the Data Registers
pointed to by R1-R0 of all four pots to their
respective Wiper Control Registers
0
0
0
1
1/0 1/0
1/0 1/0
0
0
Gang XFR Wiper
Control Registers to
Data Register
Transfer the contents of both Wiper Control
Registers to their respective data Registers
pointed to by R1-R0 of all four pots
1
0
0
0
0
1
0
0
0
0
0
0
1/0
1/0
Increment/Decrement
Wiper Control Register
Enable Increment/decrement of the Control
Latch pointed to by P1-P0
© NIDEC COPAL ELECTRONICS CORP.
Characteristics subject to change without notice
9
Doc. No. MD-2010 Rev. K
DP7409
— Global XFR Data Register to Wiper Control
Register
position), to a Data Register is a write to non-volatile
memory and takes a minimum of tWR to complete. The
transfer can occur between one of the four poten-
tiometers and one of its associated registers; or the
transfer can occur between all potentiometers and
one associated register.
This transfers the contents of all specified Data
Registers to the associated Wiper Control
Registers.
— Global XFR Wiper Counter Register to Data
Register
This transfers the contents of all Wiper Control
Registers to the specified associated Data
Registers.
Four instructions require a two-byte sequence to
complete, as illustrated in Figure 7. These instructions
transfer data between the host/processor and the
DP7409; either between the host and one of the data
registers or directly between the host and the Wiper
Control Register. These instructions are:
INCREMENT/DECREMENT COMMAND
The final command is Increment/Decrement (Figure 5
and 9). The Increment/Decrement command is
different from the other commands. Once the
command is issued and the DP7409 has responded
with an acknowledge, the master can clock the
selected wiper up and/or down in one segment steps;
thereby providing a fine tuning capability to the host.
For each SCL clock pulse (tHIGH) while SDA is HIGH,
the selected wiper will move one resistor segment
towards the RH terminal. Similarly, for each SCL clock
pulse while SDA is LOW, the selected wiper will move
one resistor segment towards the RL terminal.
— XFR Data Register to Wiper Control Register
This transfers the contents of one specified Data
Register to the associated Wiper Control Register.
— XFR Wiper Control Register to Data Register
This transfers the contents of the specified Wiper
Control Register to the specified associated Data
Register.
See Instructions format for more detail.
Figure 7. Two-Byte Instruction Sequence
SDA
0
1
0
1
ID3 ID2 ID1 ID0
S
A2 A1 A0
S
T
A
R
T
A3
A I3 I2 I1
I0
R1 R0 P1 P0
A
C
K
C
K
T
O
P
Internal
Address
Instruction
Opcode
Register
Address
Pot/WCR
Device ID
Address
Figure 8. Three-Byte Instruction Sequence
SDA
0
1
0
1
S
T
A
R
T
I3
ID3 ID2
ID0
A
C
K
I2
I1
P1 P0
I0 R1 R0
A
C
K
D7 D6 D5 D4 D3 D2 D1 D0
A
C
K
S
T
ID1
A3 A2 A1 A0
O
P
Internal
Address
Device ID
WCR[7:0]
or
Instruction
Opcode
Data
Pot/WCR
Register Address
Address
Data Register D[7:0]
Figure 9. Increment/Decrement Instruction Sequence
0
1
0
1
SDA
ID3 ID2 ID1 ID0
Device ID
I1
A3 A2 A1 A0
I3
I2
I0
R1 R0 P1 P0
S
T
A
R
T
A
C
K
A
C
K
I
I
D
E
C
1
S
I
D
N
C
1
N
C
2
T
O
P
N
C
n
E
C
n
Internal
Address
Instruction
Opcode
Pot/WCR
Address
Data
Register
Address
Doc. No. MD-2010 Rev. K
10
© NIDEC COPAL ELECTRONICS CORP.
Characteristics subject to change without notice
DP7409
Figure 10. Increment/Decrement Timing Limits
INC/DEC
Command
Issued
t
WRID
SCL
SDA
Voltage Out
R
W
INSTRUCTION FORMAT
Read Wiper Control Register (WCR)
S
T
A
R
T
A
C
K
A
C
K
A
C
K
S
DEVICE ADDRESSES
A3 A2 A1 A0
INSTRUCTION
DATA
T
O
P
0
1
0
1
1
1
1
1
0
0
0
1
0
1
1
0
1
0
0
P1 P0
7
0
6
0
5
4
3
2
1
0
Write Wiper Control Register (WCR)
S
T
A
R
T
A
C
K
A
C
K
A
C
K
S
T
DEVICE ADDRESSES
A3 A2 A1 A0
INSTRUCTION
DATA
0
1
0
1
0
0
0
P1 P0
7
0
6
0
5
4
3
2
1
0
O
P
Read Data Register (DR)
S
T
A
C
K
A
A
S
DEVICE ADDRESSES
A3 A2 A1 A0
INSTRUCTION
R1 R0 P1 P0
DATA
C
K
C
K
T
O
P
0
1
0
1
1
7
6
5
4
3
2
1
0
A
R
T
0
0
Write Data Register (DR)
S
T
A
C
K
A
C
K
A
C
K
S
T
DEVICE ADDRESSES
A3 A2 A1 A0
INSTRUCTION
R1 R0 P1 P0
DATA
0
1
0
1
0
7
0
6
0
5
4
3
2
1
0
A
R
T
O
P
© NIDEC COPAL ELECTRONICS CORP.
Characteristics subject to change without notice
11
Doc. No. MD-2010 Rev. K
DP7409
INSTRUCTION FORMAT (continued)
Global Transfer Data Register (DR) to Wiper Control Register (WCR)
S
T
A
C
K
A
C
K
S
T
DEVICE ADDRESSES
A3 A2 A1 A0
INSTRUCTION
R1 R0
0
1
0
1
0
0
0
1
0
0
A
R
T
O
P
Global Transfer Wiper Control Register (WCR) to Data Register (DR)
S
T
A
C
K
A
C
K
S
T
DEVICE ADDRESSES
A3 A2 A1 A0
INSTRUCTION
R1 R0
0
1
0
1
1
0
0
0
0
0
A
R
T
O
P
Transfer Wiper Control Register (WCR) to Data Register (DR)
S
T
A
C
K
A
C
K
S
T
DEVICE ADDRESSES
A3 A2 A1 A0
INSTRUCTION
R1 R0 P1 P0
0
1
0
1
1
1
1
0
A
R
T
O
P
Transfer Data Register (DR) to Wiper Control Register (WCR)
S
T
A
C
K
A
C
K
S
T
DEVICE ADDRESSES
A3 A2 A1 A0
INSTRUCTION
R1 R0 P1 P0
0
1
0
1
1
1
0
1
A
R
T
O
P
Increment (I)/Decrement (D) Wiper Control Register (WCR)
S
T
A
C
K
A
A
C
K
S
T
DEVICE ADDRESSES
A3 A2 A1 A0
INSTRUCTION
DATA
. . .
C
K
0
1
0
1
0
0
1
0
0
0
P1 P0
I/D I/D
I/D I/D
A
R
T
O
P
Note:
(1) Any write or transfer to the Non-volatile Data Registers is followed by a high voltage cycle after a STOP has been issued.
Doc. No. MD-2010 Rev. K
12
© NIDEC COPAL ELECTRONICS CORP.
Characteristics subject to change without notice
DP7409
PACKAGE OUTLINE DRAWINGS
SOIC 24-Lead 300mils (W) (1)(2)
SYMBOL
MIN
2.35
0.10
2.05
0.31
0.20
15.20
10.11
7.34
NOM
MAX
2.65
0.30
2.55
0.51
0.33
A
A1
A2
b
E1
E
c
D
15.40
10.51
7.60
E
E1
e
1.27 BSC
h
0.25
0.40
0°
0.75
1.27
8°
b
e
L
Q
PIN#1 IDENTIFICATION
Q1
5°
15°
TOP VIEW
h
D
h
Q1
A2
Q
A
Q1
L
c
A1
SIDE VIEW
END VIEW
Notes:
(1) All dimensions in millimeters. Angle in degrees.
(2) Compiles with JEDEC standard MS-013.
© NIDEC COPAL ELECTRONICS CORP.
Characteristics subject to change without notice
13
Doc. No. MD-2010 Rev. K
DP7409
TSSOP 24-Lead 4.4mm (Y) (1)(2)
b
SYMBOL
MIN
NOM
MAX
1.20
0.15
1.05
0.30
0.20
7.90
6.55
4.50
A
A1
A2
b
0.05
0.80
0.19
0.09
7.70
6.25
4.30
c
E1
E
D
7.80
6.40
E
E1
e
4.40
0.65 BSC
1.00 REF
0.60
L
L1
Q1
0.50
0°
0.70
8°
e
TOP VIEW
D
c
A2
A1
A
Q1
L1
L
SIDE VIEW
END VIEW
Notes:
(1) All dimensions in millimeters. Angle in degrees.
(2) Compiles with JEDEC standard MO-153.
Doc. No. MD-2010 Rev. K
14
© NIDEC COPAL ELECTRONICS CORP.
Characteristics subject to change without notice
DP7409
EXAMPLE OF ORDERING INFORMATION(1)
Prefix
Device # Suffix
DP
7409
W
I
-00
- T1
Package
W: SOIC
Y: TSSOP
Temperature Range
I = Industrial (-40ºC to 85ºC)
Resistance
25: 2.5k
10: 10k
Tape & Reel
T: Tape & Reel
1: 1000/Reel - SOIC
2: 2000/Reel - TSSOP
Company ID
50: 50k
00: 100k
Product Number
7409
ORDERING PART NUMBER
Part Number
DP7409WI-25
DP7409WI-10
DP7409WI-50
DP7409WI-00
DP7409YI-25
DP7409YI-10
DP7409YI-50
DP7409YI-00
Resistance
Package
2.5k
10k
50k
100k
2.5k
10k
SOIC
TSSOP
50k
100k
Notes:
(1) All packages are RoHS-compliant (Lead-free, Halogen-free).
(2) The device used in the above example is a DP7409WI-00-T1 (SOIC, Industrial Temperature, 100k, Tape & Reel, 1,000/Reel).
(3) For additional package and temperature options, please contact your nearest COPAL ELECTRONICS Sales office.
© NIDEC COPAL ELECTRONICS CORP.
Characteristics subject to change without notice
15
Doc. No. MD-2010 Rev. K
REVISION HISTORY
Date
Rev. Reason
10/8/2003
H
Updated Features
Updated Description
Changed Preliminary designation to Final
Eliminated Commercial temp range in all areas
04/29/06
I
¯¯¯
Updated WP Pin Description
Updated notes in Absolute Max Ratings and Potentiometer Characteristics
Deleted BGA package
Updated Potentiometer Characteristics table
Update Package Outline Drawings
Updated Example of Ordering Information
Added MD- to document number
02/05/2008
04/07/2008
J
K
Update Ordering Part Number table
NIDEC COPAL ELECTRONICS CORP. MAKES NO WARRANTY, REPRESENTATION OR GUARANTEE, EXPRESS OR IMPLIED, REGARDING THE SUITABILITY OF ITS
PRODUCTS FOR ANY PARTICULAR PURPOSE, NOR THAT THE USE OF ITS PRODUCTS WILL NOT INFRINGE ITS INTELLECTUAL PROPERTY RIGHTS OR THE
RIGHTS OF THIRD PARTIES WITH RESPECT TO ANY PARTICULAR USE OR APPLICATION AND SPECIFICALLY DISCLAIMS ANY AND ALL LIABILITY ARISING
OUT OF ANY SUCH USE OR APPLICATION, INCLUDING BUT NOT LIMITED TO, CONSEQUENTIAL OR INCIDENTAL DAMAGES.
NIDEC COPAL ELECTRONICS CORP. product s are not de signe d, int e nde d, or aut horize d for use as compone nt s in syst e ms int e nde d for surgical implant int o t he body, or
ot he r applicat ions int e nde d t o support or sust ain life , or for any ot he r applicat ion in which t he failure of t he NIDEC COPAL ELECTRONICS CORP. product could cre at e a
sit uat ion where personal injury or deat h may occur.
NIDEC COPAL ELECTRONICS CORP. re se rve s t he right t o make change s t o or discont inue any product or se rvice de scribe d he re in wit hout not ice . Product s wit h dat a she e t s
labeled "Advance Informat ion" or "Preliminary" and ot her product s described herein may not be in product ion or offered for sale.
NIDEC COPAL ELECTRONICS CORP. advise s cust ome rs t o obt ain t he curre nt ve rsion of t he re le vant product informat ion be fore placing orde rs. Circuit diagrams illust rat e
t ypical semiconduct or applicat ions and may not be complet e.
NIDEC COPAL ELECTRONICS CORP.
Japan Head Office
Nishi-Shinjuku, Kimuraya Bldg.,
7-5-25 Nishi-Shinjuku, Shinjuku-ku, Tokyo 160-0023
Document No: MD-2010
Phone: +81-3-3364-7055
Fax: +81-3-3364-7098
Revision:
K
Issue date:
04/07/08
www.nidec-copal-electronics.com
相关型号:
©2020 ICPDF网 联系我们和版权申明