HX2-4.5V [NAIS]

Compact & Slim 2 Form C Non-polarized Relay; 紧凑型和超薄2 C型非极化继电器
HX2-4.5V
型号: HX2-4.5V
厂家: NAIS(MATSUSHITA ELECTRIC WORKS)    NAIS(MATSUSHITA ELECTRIC WORKS)
描述:

Compact & Slim 2 Form C Non-polarized Relay
紧凑型和超薄2 C型非极化继电器

继电器
文件: 总3页 (文件大小:61K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Compact & Slim 2 Form C  
Non-polarized Relay  
HX-RELAYS  
FEATURES  
• Compact size of (W) 7.4 × (L) 15.0 × (H)  
9.4 mm (W) .291× (L) .591× (H) .370  
inch.  
7.4  
• High-density mounting is possible  
15.0  
.591  
.291  
• High reliability  
9.4  
.370  
The use of a gold-clad bifurcated struc-  
ture for the movable contacts, and a low  
gas material for the forming materials and  
coil wiring ensures high contact reliability.  
• Surge withstand voltage of 1,500 V  
(between contact and coil)  
Conforms to FCC Part 68.  
mm inch  
SPECIFICATIONS  
Contact  
Characteristics  
Arrangement  
2 Form C  
Max. 100 mΩ  
Initial insulation*1 resistance  
Min. 1,000 M(at 500 V DC)  
Initial contact resistance  
(By voltage drop 6 V DC 1 A)  
Between contacts  
750 V rms for 1 min.  
Initial  
breakdown  
voltage  
Between contact and  
coil  
1,000 V rms for 1 min.  
Contact material  
Gold-clad silver alloy  
1 A 30 V DC, 0.3 A 125 V AC  
Nominal switching  
capacity (resistive load)  
Between contacts sets  
1,000 V rms for 1 min.  
Temperature rise*2  
Max. 60°C  
Max. switching power  
(resistive load)  
Operate time*3  
(at 20°C 68°F)  
30 W (DC), 37.5 VA (AC)  
Max. 6 ms (Approx. 4 ms)  
Rating  
Max. switching voltage  
Max. switching current  
Min. switching capability 1  
110 V DC, 125 V AC  
Release time(without diode)*3  
(at 20°C 68°F)  
Max. 5 ms (Approx. 3 ms)  
1 A  
1 mA 1 V DC  
320 mW  
107  
Functional*4  
Destructive*5  
Min. 100 m/s2 {10G}  
Min. 1,000 m/s2 {100G}  
Shock resistance  
Nominal operating power  
Mechanical (at 180 cpm)  
10 to 55 Hz  
at double amplitude of 1.0 mm  
Functional*6  
Expected  
life (min.  
operations)  
105  
Vibration resistance  
Electrical (at 20 cpm)  
(1 A 30 V DC,  
0.3 A 125 V AC resistive)  
10 to 55 Hz  
at double amplitude of 1.5 mm  
Destructive  
Ambient  
temperature  
–40 to +70°C  
–40 to +158°F  
Note:  
1This value can change due to the switching frequency, environmental conditions,  
Conditions for  
opetation, transport  
and storage*7  
and desired reliability level, therefore it is recommended to check this with the ac-  
tual load.  
Remarks  
Humidity  
5 to 85% R.H.  
Atmospheric  
pressure  
86 to 106 kPa  
* Specifications will vary with foreign standards certification ratings.  
*1 Measurement at same location as "Initial breakdown voltage" section.  
*2 By resistive method, nominal voltage applied to the coil; contact carrying current:  
1A.  
Unit weight  
Approx. 2g .07 oz  
*3 Nominal voltage applied to the coil, excluding contact bounce time.  
*4 Half- wave pulse of sine wave: 11ms, detection time: 10µs  
*5 Half- wave pulse of sine wave: 6ms  
*6 Detection time: 10µs  
*7 Refer to 5. Conditions for operation, transport and storage mentioned in  
AMBIENT ENVIRONMENT (Page 61)  
TYPICAL  
ORDERING INFORMATION  
APPLICATIONS  
Ex. HX  
2
3V  
Telephone exchange, transmission  
equipment  
• Communications devices  
• Measurement devices  
• Home appliances, and audio/visual  
equipment  
Contact arrangement  
2: 2 Form C  
Coil voltage(DC)  
1.5, 3, 4.5, 5, 6, 9, 12, 24 V  
Note: 2,500V Surge (Bellcore) type is also available.  
Please consult us for details.  
• Office equipment  
183  
HX  
TYPES AND COIL DATA  
Part No.  
Normal  
operating  
current,  
mA (±10%)  
(at 20°C 68°F)  
Pick-up  
voltage,  
V DC (max.)  
Drop-out  
voltage,  
V DC (min.)  
Coil  
Nominal  
operating  
power,  
mW  
Max. allowable  
voltage,  
V DC  
(at 70°C 158°F)  
Standard  
PC board  
terminal  
Contact  
arrangement  
Coil rating,  
V DC  
Resistance,  
ohm (±10%)  
(at 20°C 68°F)  
(at 20°C 68°F) (at 20°C 68°F)  
arrangement  
1.5  
3
HX2-1.5V  
HX2-3V  
HX2-4.5V  
HX2-5V  
HX2-6V  
HX2-9V  
HX2-12V  
HX2-24V  
1.13  
2.25  
3.38  
3.75  
4.5  
0.15  
0.3  
0.45  
0.5  
0.6  
0.9  
1.2  
2.4  
214  
107  
7.0  
28.1  
63.3  
78.1  
112  
320  
320  
320  
320  
320  
320  
320  
320  
1.65  
3.3  
4.5  
5
71.1  
64.0  
53.6  
35.6  
26.7  
13.3  
4.95  
5.5  
2 Form C  
6
6.6  
9
6.75  
9
253  
9.9  
12  
24  
450  
13.2  
26.4  
18  
1,800  
Standard packing: Tube; 40 pcs.; Case : 1,000 pcs.  
mm inch  
DIMENSIONS  
1. Standard PC board terminal type  
PC board pattern (Bottom view)  
Schematic (Bottom view)  
10.16  
15.00  
.591  
7.4  
.400  
8-1 dia  
8-.039 dia  
.291  
1
3
4
5
8
2.54  
.100  
9.4  
0.45  
.370  
5.08  
.200  
.018  
12 10 9  
3.5  
2.54  
.100  
.138  
0.25  
.010  
0.5  
.020  
5.08  
.200  
1.15  
.138  
5.08  
.200  
2.54  
.100  
General tolerance: ±0.3 ±.012  
Tolerance: ±0.1 ±.004  
REFERENCE DATA  
1. Maximum switching capacity  
2. Life curve  
3. Mechanical life  
Tested sample: HX2-12 V, 10 pcs.  
100  
90  
200  
DC load (cos ϕ = 1)  
AC load (cos ϕ = 1)  
3.0  
2.0  
80  
100  
50  
Pick-up voltage  
Drop-out voltage  
70  
60  
50  
40  
30  
20  
10  
0
Max.  
Min.  
1.0  
30 V DC  
resistive load  
30  
20  
0.5  
0.4  
0.3  
125 V AC  
resistive load  
0.2  
Max.  
Min.  
10  
0.2  
0.4  
0.6  
0.8  
1.0  
1.2  
20 30  
50  
100  
200 300  
100  
500  
1,000  
No. of operations, ×104  
Switching current, A  
Switching voltage, V  
4. Electrical life (1 A 30 V DC resistive load)  
5. Coil temperature rise  
Tested sample: HX2-12 V, 6 pcs.  
Operating frequency: 20 cpm  
Change of pick-up and drop-out voltage  
100  
Tested sample: HX2-12 V  
Measured portion: Inside the coil  
Ambient temperature: 25°C 77°F, 70°C 158°F  
Change of contact resistance  
100  
70  
1 A  
70°C 158°F  
0 A  
90  
80  
70  
90  
80  
70  
60  
50  
40  
30  
20  
10  
Room  
60  
50  
40  
30  
20  
10  
0
temperature  
1 A  
0 A  
(25°C 77°F)  
Pick-up voltage  
Drop-out voltage  
Max.  
Min.  
60  
50  
40  
30  
20  
10  
0
Max.  
Min.  
Max.  
Min.  
0
5
10  
5
No. of operations, ×104  
10  
100 110 120 130 140 150  
Coil applied voltage, %V  
No. of operations, ×104  
184  
HX  
6. Operate/release time characteristics  
Tested sample: HX2-12V, 10 pcs.  
7. Distribution of pick-up and drop-out voltage  
Tested sample: HX2-12V, 50 pcs.  
8. Ambient temperature characteristics  
Tested sample: HX2-12V, 5 pcs.  
6
5
4
–40  
Drop-out  
voltage  
35  
–30  
–20  
–10  
30  
Drop-out voltage  
25  
Pick-up voltage  
20  
Pick-up voltage  
20 40 60 80  
–40 –20  
0
Set time  
3
2
1
0
Max.  
Min.  
Ambient temperature, °C  
15  
10  
5
–10  
–20  
–30  
–40  
Reset time  
Max.  
Min.  
0
80  
90  
100 110 120  
10 20 30 40 50 60 70 80 90 100  
Coil applied voltage, %V  
Ratio against the rated voltage, %V  
9. Distribution of contact resistance  
Tested sample: HX2-12V, 25 pcs. (25 × 4 contacts)  
10.-(1) High frequency characteristics  
Isolation characteristics  
10.-(2) High frequency characteristics  
Insertion loss characteristics  
50  
40  
30  
20  
10  
0
100  
50  
0.5  
0.4  
0.3  
0.2  
0.1  
0
10  
100  
1,000  
20  
30  
40  
10  
100  
1,000  
Frequency, MHZ  
Contact resistance, mΩ  
Frequency, MHZ  
NOTES  
1. Coil operating power  
3. Packing style  
• Packing direction  
The relay is packed in a tube with the relay  
orientation mark on the left side, as shown  
in the figure below.  
Take note of the relay orientation when  
mounting relays on the printed circuit  
board.  
4. Automatic insertion  
Pure DC current should be applied to the  
coil.The wave form should be rectangular.  
If it includes ripple, the ripple factor should  
be less than 5%.  
However, check it with the actual circuit  
since the characteristics may be slightly  
different. The nominal operating voltage  
should be applied to the coil for more than  
10 ms to set/reset the latching type relay.  
2. Cleaning  
In automatic cleaning, cleaning with the  
boiling method is recommended. Avoid ul-  
trasonic cleaning which subject the relay  
to high frequency vibrations. It may cause  
the contacts to stick.  
To maintain the internal function of the re-  
lay, the chucking pressurre should not ex-  
ceed the values below.  
Chucking pressure in direction A:  
9.8 N {1 kgf} or less  
Chucking pressure in direction B:  
9.8 N {1 kgf} or less  
Chucking pressure in direction C:  
4.9 N {500 gf} or less  
Orientation (indicates PIN No. 1) stripe  
C
B
A
Stopper  
(gray)  
Stopper  
(green)  
lt is recommended that a fluorinated hy-  
drocarbon or other alcoholic solvent be  
used.  
Please chuck the  
Avoid chucking the center of the relay.  
portion.  
The temperature range is –40 to +70°C  
–40 to +158°F  
For Cautions for Use, see Relay Technical Information (Page 48 to 76).  
9/1/2000  
All Rights Reserved, © Copyright Matsushita Electric Works, Ltd.  
Go To Online Catalog  

相关型号:

HX2-5V

Compact & Slim 2 Form C Non-polarized Relay
NAIS

HX2-6V

Compact & Slim 2 Form C Non-polarized Relay
NAIS

HX2-9V

Compact & Slim 2 Form C Non-polarized Relay
NAIS

HX20-P

Current Transducer HX 03~50-P
LEM

HX20-P/SP2

Current Transducer HX 03~50-P/SP2
LEM

HX20-SP2

Current Transducer
LEM

HX2000

RICMOS⑩ SOI GATE ARRAYS
HONEYWELL

HX20000000J0G

Barrier Strip Terminal Block
AMPHENOL

HX20004000J0G

Barrier Strip Terminal Block
AMPHENOL

HX20008000J0G

Barrier Strip Terminal Block,
AMPHENOL

HX2000R

RICMOS⑩ SOI GATE ARRAYS
HONEYWELL

HX20013000J0G

Barrier Strip Terminal Block
AMPHENOL