HX20-SP2 [LEM]
Current Transducer; 电流传感器型号: | HX20-SP2 |
厂家: | LEM |
描述: | Current Transducer |
文件: | 总2页 (文件大小:645K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Current Transducer HX 03..50-P/SP2
IPN = 3 .. 50 A
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
Electrical data
Primarynominal Primary current,
current rms
Primary conductor
diameter x turns
(mm)
Type
RoHS since
date code
measuring range1)
Features
IPN (A)
IPM (A)
· Galvanicisolationbetweenprimary
andsecondarycircuit
· Halleffectmeasuringprinciple
· Isolationvoltage 3000V
3
5
± 9
0.6d x 20T
0.8d x 12T
1.1d x 6T
1.4d x 4T
1.6d x 3T
HX 03-P/SP2
HX 05-P/SP2
HX 10-P/SP2
HX 15-P/SP2
HX 20-P/SP2
HX 25-P/SP2
HX 50-P/SP2
46128
46019
45352
46133
planned
46233
46152
± 15
± 30
± 45
± 60
± 75
± 150
10
15
20
25
50
· Low power consumption
1.6d x 2T
1.2 x 6.3 x 1T
· Extended measuring range(3x IPN
· Insulated plastic case recognized
according to UL94-V0.
)
VOUT
Output voltage (Analog) @ ± IPN, RL = 2 kW, TA = 25°C VOE ± 0.625
V
W
ROUT
RL
VC
IC
Output internal resistance
Load resistance
< 50
³ 2
kW
V
Special feature
Supply voltage (± 5 %)
+ 12 .. 15
< 15
> 3
Current consumption
mA
kV
kV
kV
· Single supply from +12V to +15V
Vd
Rms voltage for AC isolation test, 50 Hz, 1 min
Ve
Partial discharge extinction voltage rms @ 10 pC ³ 1
Impulse withstand voltage, 1.2/50 µs ³ 6
Advantages
VW
· Low insertion losses
· Easy to mount with automatic
handling system
· Small size and space saving
· Only one design for wide current
ratings range
Accuracy-Dynamic performance data
X
Accuracy @ IPN, TA = 25°C (excluding offset)
Linearity error (0 .. ± IPN)
< ± 1 % of IPN
< ± 1 % of IPN
+ 2.5V ± 50 mV
e
L
VOE
VOH
Electrical offset voltage @ TA = 25°C
Hysteresis offset voltage @ IP = 0;
after an excursion of 1 x IPN
· High immunity to external
interference.
< ± 10
mV
TCVOE
TCVOUT
tr
Temperature coefficient of VOE
< ± 1.5 mV/K
Temperature coefficient of VOUT (% of reading)
Response time to 90% of IPN step
Frequency bandwidth (- 3 dB) 2)
± 0.1
£ 3
%/K
µs
Applications
BW
50
kHz
· Switched Mode Power Supplies
(SMPS)
General data
· ACvariablespeeddrives
· UninterruptiblePowerSupplies
(UPS)
· Electricalappliances
· Batterysuppliedapplications
· DC motor drives
TA
Ambient operating temperature
Ambient storage temperature
Mass
- 25 .. + 85 °C
- 25 .. + 85 °C
TS
m
8
g
dCp
Creepage distance
Isolation material group
Standards
³ 5.5
m m
I
EN50178: 1997
Applicationdomain
· Industrial
Notes : 1) With RL=2kW
2)
Small signal only to avoid excessive heating of the magnetic core
Page 1/2
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
061026/5
www.lem.com
Dimensions HX 03..50-P/SP2 (in mm. 1 mm = 0.0394 inch)
HX 03..25-P/SP2
HX 50-P/SP2
Max.
Max.
19
19
Terminal Pin Identification
1 ..... 0V
2 ..... 0V
3 ..... +12V to +15V
4 ..... Output
5 ..... Primary input Current (+)
6 ..... Primary input Current (-)
10.85
8.8
5.4
3
3
Primary conductor diameter
d
03-P/
SP2
05-P/
SP2
10-P/
SP2
15-P/
SP2
Bottomview
Bottomview
HX
d
6
5
6
5
0.6
0.8
1.1
1.4
4 OUT
3 +V
4 OUT
3 +V
20-P/
SP2
25-P/
SP2
50-P/
SP2
HX
d
0
0
2
1
2
1
-V or 0
-V or 0
1.6
1.6
1.2 x 6.3
1.2
8.8
3
10.85
3
5.4
Secondary pins dimension
0.5 x 0.25
Top view
HX05-P/
SP2
41123
Lot No.
Safety
This transducer must be used in electric/electronic equipment
with respect to applicable standards and safety requirements
in accordance with the following manufacturer's operating
instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can
carry hazardous voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious
damage.
This transducer is a built-in device, whose conducting parts
must be inaccessible after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
Page 2/2
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
061026/5
www.lem.com
相关型号: