DIESEl GENERATOR SET
AIR CHARGE-AIR COOlING
/
/
300 kVA 50 Hz Standby (Fuel-Optimized)
380 - 415V
(Reference DP275D5S – Fuel optimized and DP275D5S – Exhaust optimized for prime rating technical data)
Optionaꢀ equipment shown. Standard equipment may vary.
BENEFITS
//
//
//
//
//
low instaꢀꢀation cost
Best fueꢀ consumption vaꢀues
long maintenance intervaꢀs
High-efficiency components
Best-in-cꢀass reꢀiabiꢀity and avaiꢀabiꢀity
➀
SYSTEM RATINGS
Standby
DS300D5S
DS300D5S
DS300D5S
Voltage (L-L)
Phase
380V
3
400V
3
415V
3
PF
0.8
0.8
0.8
Hz
50
50
50
kW
240
240
240
kVA
300
300
300
AMPS
456
433
417
Generator Modeꢀ
Temp Rise
Connection
433PSl7516
150°C/40°C
12 lEAD HI WYE
433PSl7516
150°C/40°C
12 lEAD HI WYE
433PSl7516
150°C/40°C
12 lEAD HI WYE
➀ Power avaiꢀabꢀe up to 40°C/400 m
/ // /
2
50 Hz 300 kVA
CERTIFICATIONS AND STANDARDS
//
//
Engine-generator set is designed and manufactured in
Power Rating
faciꢀities certified to standards ISO 9001:2008 and
ISO 14001:2004
Performance Assurance Certification (PAC)
- Permissibꢀe average power output during 24 hours of
operation up to 85%
//
- Engine-generator set tested according to ISO 8528-5 for
transient response
- Verified product design, quaꢀity and performance integrity
- Aꢀꢀ engine systems are prototype and factory tested
STANDARD EQUIPMENT*
//
//
Engine
Generator
Air cꢀeaner
Oiꢀ pump
NEMA MG1, IEEE and ANSI standards compꢀiance for temperature rise
and motor starting
Oiꢀ drain extension & s/o vaꢀve
Fuꢀꢀ flow oiꢀ fiꢀters
Cꢀosed crankcase ventiꢀation
Jacket water pump
VDE 0530, IEC 34.1, BS 5000, CSA 22.2-100, AS 1359
Sustained short circuit current of up to 300% of the rated current
for up to 10 seconds
Seꢀf-ventiꢀated and drip-proof
Superior voꢀtage waveform
Thermostat
Exhaust manifoꢀd – dry
Bꢀower fan & fan drive
Radiator – unit mounted
Eꢀectric starting motor – 24V
Governor – eꢀectronic isochronous
Base – formed steeꢀ
Digitaꢀ, soꢀid state, voꢀts-per-hertz reguꢀator
No ꢀoad to fuꢀꢀ ꢀoad reguꢀation
Brushꢀess aꢀternator with brushꢀess piꢀot exciter
4 poꢀe, rotating fieꢀd
150°C maximum standby temperature rise
1 bearing, seaꢀed
SAE flywheeꢀ & beꢀꢀ housing
Charging aꢀternator – 24V
Fꢀexibꢀe fueꢀ connectors
Fueꢀ system: common raiꢀ
Fꢀexibꢀe coupꢀing
Fuꢀꢀ amortisseur windings
125% rotor baꢀancing
3-phase voꢀtage sensing
1% voꢀtage reguꢀation
100% of rated ꢀoad – one step
3% maximum harmonic content
Insuꢀation cꢀass H
//
Customer Interface
Smart connect
Protection cꢀass IP20
➀ Represents standard product onꢀy.Consuꢀt Factory/MTU Onsite Energy distributor for additionaꢀ configurations.
/ // /
3
50 Hz 300 kVA
➀
STANDARD FEATURES
//
//
The generator set compꢀies to G2
Engine-generator set tested to ISO 8528-5 for transient
response
Cooꢀing system 50°C (integraꢀ set-mounted; engine driven
fan)
6R1600 dieseꢀ engine (10,5 ꢀiter dispꢀacement; common raiꢀ
fueꢀ injection; 4-cycꢀe)
Engine-generator resiꢀientꢀy mounted
Compꢀete range of accessories
Brushꢀess, rotating fieꢀd generator (PMG excitation;
300% short circuit capabiꢀity; 2/3 pitch stator windings)
Terminaꢀ box
//
//
//
//
//
//
//
Accepts rated ꢀoad in one step per NFPA 110
//
//
//
Aꢀꢀ engine-generator sets are protoype and factory tested
MTU Onsite Energy is a singꢀe source suppꢀier
Gꢀobaꢀ product support
2 year standard warranty
//
APPlICATION DATA
//
//
Engine
Fuel Consumption
Standby
Manufacturer
Modeꢀ
Type
MTU
6R1600G70F
4-Cycꢀe
At 100% of power rating: ꢀ/hr (gaꢀ/hr)
At 75% of power rating: ꢀ/hr (gaꢀ/hr)
At 50% of power rating: ꢀ/hr (gaꢀ/hr)
65 (17.2)
49 (12.9)
33 (8.8)
Arrangement
Inꢀine 6
//
Dispꢀacement/cyꢀinder: ꢀ (cu in)
Bore: mm (in)
10.5 (641)
122 (4.8)
150 (5.91)
17.5:1
1500
ECU 8
274 (367)
0.25%
Cooling/Radiator System
Standby
50 (122)
Stroke: mm (in)
Compression ratio
Rated speed rpm
Engine governor
Max power: kWm (bhp)
Speed reguꢀation
Air fiꢀter
Ambient capacity of radiator: °C (°F)
Max. restriction of cooꢀing air, intake,
and discharge side of rad.: kPa (in. H20)
Water pump capacity: ꢀ/min (gpm)
Heat rejection to cooꢀant: kW (BTUM)
Heat rejection to after cooꢀer: kW (BTUM)
Heat radiated to ambient: kW (BTUM)
Engine cooꢀant capacity: ꢀ (gaꢀ)
0,2 (0,803)
277 (73,1)
144 (8,189)
60 (3,412)
14 (796)
Dry
45 (11,9)
44 (11,6)
95 (203)
//
Lube Oil Capacity
Radiator cooꢀant capacity: ꢀ (gaꢀ)
Cooꢀant to cooꢀer temperature: °C (°F)
Totaꢀ oiꢀ system: ꢀ (gaꢀ)
46 (12.2)
➂
//
Air Requirements
//
Electrical
Standby
24 (847.6)
Aspirating: m3/min (SCFM)
Air flow required for rad.
Eꢀectric Voꢀts DC
24
Coꢀd cranking amps under -17.8°C (0°F)
1000
cooꢀed unit: m3/min (SCFM)
Remote cooꢀed appꢀications;
air flow required for dissipation
of radiated gen-set heat for a
max of 25°F rise: m3/min (SCFM)
372 (13,137)
102 (3,590.7)
//
Fuel System
➀
Fueꢀ suppꢀy connection size
24°Cone M22 x 1,5 - 60°/Maꢀe
24°Cone M16 x 1,5 - 60°/Maꢀe
5 (16)
see MTU fluids & ꢀubrication spec.
171 (52.1)
➀
Fueꢀ return connection size
Maximum fueꢀ ꢀift: m (ft)
Recommended fueꢀ
//
Exhaust System
Standby
485 (905)
Totaꢀ fueꢀ flow: ꢀ/hr (gaꢀ/hr)
Gas temp. (stack): °C (°F)
Gas voꢀume at stack
temp: m3/min (CFM)
Maximum aꢀꢀowabꢀe
back pressure: kPA (in. H20)
60 (2,118.9)
15 (60.2)
➀ Represents standard product onꢀy.Consuꢀt Factory/MTU Onsite Energy distributor for additionaꢀ configurations.
➂ Air density = 1.184 kg/m3 (0.0739 ꢀbm/ft3)
/ // /
4
50 Hz 300 kVA
WEIGHTS AND DIMENSIONS
H
L
W
Drawing above for iꢀꢀustration purposes onꢀy, based an standard open power 400 Voꢀt engine-generator set. lengths may vary with other voꢀtages. Do not use for instaꢀꢀation design.
See website for unit specific tempꢀate drawings.
System
Dimensions (LxWxH)
Weight (dry)
Open Power Unit (OPU)
3658 x 1445 x 1855 mm (144 x 56.875 x 73 in)
3078 kg (6,785 ꢀbs)
Weights and dimensions are based on open power units and are estimates onꢀy. Consuꢀt the factory for accurate weights and dimensions for your specific engine-generator set.
SOUND DATA
Unit Type
Prime Full Load
leveꢀ 0: Open Power Unit (dBA)
85.0
Sound data is provided at 7 m (23 ft). Engine-generator set tested in accordance with ISO 8528-10 and with infinite exhaust.
EMISSIONS DATA
//
Consuꢀt your ꢀocaꢀ MTU Onsite Energy distributor for emissions data.
RATING DEFINITIONS AND CONDITIONS
//
Standby ratings appꢀy to instaꢀꢀations served by a reꢀiabꢀe utiꢀity source. The standby rating is appꢀicabꢀe to varying ꢀoads for
the duration of a power outage. No overꢀoad capabiꢀity for this rating. Ratings are in accordance with ISO 8528-1, ISO 3046-1,
BS 5514, AS 2789 and DIN 6271.
Deration factor:
//
Aꢀtitude: Consuꢀt your ꢀocaꢀ MTU Onsite Energy distributor for aꢀtitude derations.
Temperature: Consuꢀt your ꢀocaꢀ MTU Onsite Energy distributor for temperature derations.
Materiaꢀs and specifications subject to change without notice.
MTU Onsite Energy
A Rolls-Royce Power Systems Brand
www.mtuonsiteenergy.com
相关型号:
DS03011012KVP1800PF+/-10%R230
Data Line Filter, 1 FUNCTIONS, 12000 V, 10 A, FEED THROUGH CAPACITOR, PANEL MOUNT
VISHAY
DS03011012KVP1800PF+/-20%R230
Data Line Filter, 1 FUNCTIONS, 12000 V, 10 A, FEED THROUGH CAPACITOR, PANEL MOUNT
VISHAY
DS03011012KVP800PF+/-5%R85
Data Line Filter, 1 FUNCTIONS, 12000 V, 10 A, FEED THROUGH CAPACITOR, PANEL MOUNT
VISHAY
©2020 ICPDF网 联系我们和版权申明