DS0330D5S [MTU]

DIESEl GENERATOR SET AIR CHARGE-AIR COOlING;
DS0330D5S
型号: DS0330D5S
厂家: MTU ONSITE ENERGY CORPORATION    MTU ONSITE ENERGY CORPORATION
描述:

DIESEl GENERATOR SET AIR CHARGE-AIR COOlING

文件: 总4页 (文件大小:2386K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
DIESEl GENERATOR SET  
AIR CHARGE-AIR COOlING  
/
/
330 kVA 50 Hz Standby (Fuel-Optimized)  
380 - 415V  
(Reference DP275D5S – Fuel optimized and DP275D5S – Exhaust optimized for prime rating technical data)  
Optionaꢀ equipment shown. Standard equipment may vary.  
BENEFITS  
//  
//  
//  
//  
//  
low instaꢀꢀation cost  
Best fueꢀ consumption vaꢀues  
long maintenance intervaꢀs  
High-efficiency components  
Best-in-cꢀass reꢀiabiꢀity and avaiꢀabiꢀity  
SYSTEM RATINGS  
Standby  
DS330D5S  
DS330D5S  
DS330D5S  
Voltage (L-L)  
Phase  
380V  
3
400V  
3
415V  
3
PF  
0.8  
0.8  
0.8  
Hz  
50  
50  
50  
kW  
264  
264  
264  
kVA  
330  
330  
330  
AMPS  
501  
476  
459  
Generator Modeꢀ  
Temp Rise  
Connection  
433PSl7516  
150°C/40°C  
12 lEAD HI WYE  
433PSl7516  
150°C/40°C  
12 lEAD HI WYE  
433PSl7516  
150°C/40°C  
12 lEAD HI WYE  
Power avaiꢀabꢀe up to 40°C/400 m  
/ // /  
2
50 Hz 330 kVA  
CERTIFICATIONS AND STANDARDS  
//  
//  
Engine-generator set is designed and manufactured in  
Power Rating  
faciꢀities certified to standards ISO 9001:2008 and  
ISO 14001:2004  
Performance Assurance Certification (PAC)  
- Permissibꢀe average power output during 24 hours of  
operation up to 85%  
//  
- Engine-generator set tested according to ISO 8528-5 for  
transient response  
- Verified product design, quaꢀity and performance integrity  
- Aꢀꢀ engine systems are prototype and factory tested  
STANDARD EQUIPMENT  
//  
//  
Engine  
Generator  
Air cꢀeaner  
Oiꢀ pump  
NEMA MG1, IEEE and ANSI standards compꢀiance for temperature rise  
and motor starting  
Oiꢀ drain extension & s/o vaꢀve  
Fuꢀꢀ flow oiꢀ fiꢀters  
Cꢀosed crankcase ventiꢀation  
Jacket water pump  
VDE 0530, IEC 34.1, BS 5000, CSA 22.2-100, AS 1359  
Sustained short circuit current of up to 300% of the rated current  
for up to 10 seconds  
Seꢀf-ventiꢀated and drip-proof  
Superior voꢀtage waveform  
Thermostat  
Exhaust manifoꢀd – dry  
Bꢀower fan & fan drive  
Radiator – unit mounted  
Eꢀectric starting motor – 24V  
Governor – eꢀectronic isochronous  
Base – formed steeꢀ  
Digitaꢀ, soꢀid state, voꢀts-per-hertz reguꢀator  
No ꢀoad to fuꢀꢀ ꢀoad reguꢀation  
Brushꢀess aꢀternator with brushꢀess piꢀot exciter  
4 poꢀe, rotating fieꢀd  
150°C maximum standby temperature rise  
1 bearing, seaꢀed  
SAE flywheeꢀ & beꢀꢀ housing  
Charging aꢀternator – 24V  
Fꢀexibꢀe fueꢀ connectors  
Fueꢀ system: common raiꢀ  
Fꢀexibꢀe coupꢀing  
Fuꢀꢀ amortisseur windings  
125% rotor baꢀancing  
3-phase voꢀtage sensing  
1% voꢀtage reguꢀation  
//  
Customer Interface  
100% of rated ꢀoad – one step  
3% maximum harmonic content  
Insuꢀation cꢀass H  
Smart connect  
Protection cꢀass IP20  
Represents standard product onꢀy.Consuꢀt Factory/MTU Onsite Energy distributor for additionaꢀ configurations.  
/ // /  
3
50 Hz 330 kVA  
STANDARD FEATURES  
//  
//  
The generator set compꢀies to G2  
Engine-generator set tested to ISO 8528-5 for transient  
response  
Cooꢀing system 50°C (integraꢀ set-mounted; engine driven  
fan)  
6R1600 dieseꢀ engine (10,5 ꢀiter dispꢀacement; common raiꢀ  
fueꢀ injection; 4-cycꢀe)  
Engine-generator resiꢀientꢀy mounted  
Compꢀete range of accessories  
Brushꢀess, rotating fieꢀd generator (PMG excitation;  
300% short circuit capabiꢀity; 2/3 pitch stator windings)  
Terminaꢀ box  
//  
//  
//  
//  
//  
//  
//  
Accepts rated ꢀoad in one step per NFPA 110  
//  
//  
//  
Aꢀꢀ engine-generator sets are protoype and factory tested  
MTU Onsite Energy is a singꢀe source suppꢀier  
Gꢀobaꢀ product support  
2 year standard warranty  
//  
APPlICATION DATA  
//  
//  
Engine  
Fuel Consumption  
Standby  
Manufacturer  
Modeꢀ  
Type  
MTU  
6R1600G80F  
4-Cycꢀe  
At 100% of power rating: ꢀ/hr (gaꢀ/hr)  
At 75% of power rating: ꢀ/hr (gaꢀ/hr)  
At 50% of power rating: ꢀ/hr (gaꢀ/hr)  
72 (18.9)  
53 (13.9)  
36 (9.6)  
Arrangement  
Inꢀine 6  
//  
Dispꢀacement/cyꢀinder: ꢀ (cu in)  
Bore: mm (in)  
10.5 (641)  
122 (4.8)  
150 (5.91)  
17.5:1  
1500  
ECU 8  
301 (403)  
0.25%  
Cooling/Radiator System  
Standby  
50 (122)  
Stroke: mm (in)  
Compression ratio  
Rated speed rpm  
Engine governor  
Max power: kWm (bhp)  
Speed reguꢀation  
Air fiꢀter  
Ambient capacity of radiator: °C (°F)  
Max. restriction of cooꢀing air, intake,  
and discharge side of rad.: kPa (in. H20)  
Water pump capacity: ꢀ/min (gpm)  
Heat rejection to cooꢀant: kW (BTUM)  
Heat rejection to after cooꢀer: kW (BTUM)  
Heat radiated to ambient: kW (BTUM)  
Engine cooꢀant capacity: ꢀ (gaꢀ)  
0,2 (0,803)  
277 (73,1)  
155 (8,815)  
65 (3,696)  
14 (796)  
Dry  
45 (11,9)  
44 (11,6)  
95 (203)  
//  
Lube Oil Capacity  
Radiator cooꢀant capacity: ꢀ (gaꢀ)  
Cooꢀant to cooꢀer temperature: °C (°F)  
Totaꢀ oiꢀ system: ꢀ (gaꢀ)  
46 (12.2)  
//  
Air Requirements  
//  
Electrical  
Standby  
24 (847.6)  
Aspirating: m3/min (SCFM)  
Air flow required for rad.  
Eꢀectric Voꢀts DC  
24  
Coꢀd cranking amps under -17.8°C (0°F)  
1000  
cooꢀed unit: m3/min (SCFM)  
Remote cooꢀed appꢀications;  
air flow required for dissipation  
of radiated gen-set heat for a  
max of 25°F rise: m3/min (SCFM)  
372 (13,137)  
110 (3,873)  
//  
Fuel System  
Fueꢀ suppꢀy connection size  
24°Cone M22 x 1,5 - 60°/Maꢀe  
24°Cone M16 x 1,5 - 60°/Maꢀe  
5 (16)  
see MTU fluids & ꢀubrication spec.  
171 (52.1)  
Fueꢀ return connection size  
Maximum fueꢀ ꢀift: m (ft)  
Recommended fueꢀ  
//  
Exhaust System  
Standby  
480 (896)  
Totaꢀ fueꢀ flow: ꢀ/hr (gaꢀ/hr)  
Gas temp. (stack): °C (°F)  
Gas voꢀume at stack  
temp: m3/min (CFM)  
Maximum aꢀꢀowabꢀe  
back pressure: kPA (in. H20)  
60 (2,118.9)  
15 (60.2)  
Represents standard product onꢀy.Consuꢀt Factory/MTU Onsite Energy distributor for additionaꢀ configurations.  
Air density = 1.184 kg/m3 (0.0739 ꢀbm/ft3)  
/ // /  
4
50 Hz 330 kVA  
WEIGHTS AND DIMENSIONS  
H
L
W
Drawing above for iꢀꢀustration purposes onꢀy, based an standard open power 400 Voꢀt engine-generator set. lengths may vary with other voꢀtages. Do not use for instaꢀꢀation design.  
See website for unit specific tempꢀate drawings.  
System  
Dimensions (LxWxH)  
Weight (dry)  
Open Power Unit (OPU)  
3658 x 1445 x 1855 mm (144 x 56.875 x 73 in)  
3078 kg (6,785 ꢀbs)  
Weights and dimensions are based on open power units and are estimates onꢀy. Consuꢀt the factory for accurate weights and dimensions for your specific engine-generator set.  
SOUND DATA  
Unit Type  
Prime Full Load  
leveꢀ 0: Open Power Unit (dBA)  
85.3  
Sound data is provided at 7 m (23 ft). Engine-generator set tested in accordance with ISO 8528-10 and with infinite exhaust.  
EMISSIONS DATA  
//  
Consuꢀt your ꢀocaꢀ MTU Onsite Energy distributor for emissions data.  
RATING DEFINITIONS AND CONDITIONS  
//  
Standby ratings appꢀy to instaꢀꢀations served by a reꢀiabꢀe utiꢀity source. The standby rating is appꢀicabꢀe to varying ꢀoads for  
the duration of a power outage. No overꢀoad capabiꢀity for this rating. Ratings are in accordance with ISO 8528-1, ISO 3046-1,  
BS 5514, AS 2789 and DIN 6271.  
Deration factor:  
//  
Aꢀtitude: Consuꢀt your ꢀocaꢀ MTU Onsite Energy distributor for aꢀtitude derations.  
Temperature: Consuꢀt your ꢀocaꢀ MTU Onsite Energy distributor for temperature derations.  
Materiaꢀs and specifications subject to change without notice.  
MTU Onsite Energy  
A Rolls-Royce Power Systems Brand  
www.mtuonsiteenergy.com  

相关型号:

DS0331

Interface IC
ETC

DS0332

Interface IC
ETC

DS0338

Interface IC
ETC

DS0342

Interface IC
ETC

DS0343

Interface IC
ETC

DS0345

PIN DIODE SP5T
DAICO

DS0347

Interface IC
ETC

DS0352

Interface IC
ETC

DS0354

Interface IC
ETC

DS0378

Interface IC
ETC

DS0379

Interface IC
ETC

DS0382

Interface IC
ETC