LF303RU [MPD]

Very Wide Input, 3W SMT Single & Dual Output DC/DC Converters; 很宽的输入, 3W SMT单,双输出DC / DC转换器
LF303RU
型号: LF303RU
厂家: MICROPOWER DIRECT, LLC    MICROPOWER DIRECT, LLC
描述:

Very Wide Input, 3W SMT Single & Dual Output DC/DC Converters
很宽的输入, 3W SMT单,双输出DC / DC转换器

转换器
文件: 总2页 (文件大小:233K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
LF300RU Series  
Very Wide Input, 3W SMT  
Single & Dual Output  
DC/DC Converters  
Electrical Specifications  
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.  
Input  
Parameter  
Conditions  
24 VDC Input  
48 VDC Input  
Min.  
4.5  
Typ.  
6.0  
Max.  
8.5  
Units  
Key Features:  
3W Output Power  
Input Start Voltage  
VDC  
8.5  
12.0  
17.0  
1.0  
Wide 4:1 Inputs  
Reverse Polarity Input Current  
Short Circuit Input Power  
Input Filter  
A
Miniature SMT Case  
Tight Line/Load Regulation  
1,500 VDC Isolation  
-40ºC to +71ºC Operation  
14 Standard Models  
1.0 MH MTBF Minimum  
Industry Standard Pin-Out  
2,000  
mW  
π (Pi) Filter (Meets EN55022 Class A)  
Output  
Parameter  
Conditions  
Min.  
Typ.  
0.5  
0.5  
0.2  
0.3  
50  
Max.  
1.0  
2.0  
1.0  
1.0  
75  
Units  
%
Output Voltage Accuracy  
Output Voltage Balance  
Line Regulation  
Dual Output, Balanced Load  
For Vin = Min to Max  
Iout = 10% to 100%  
%
%
Load Regulation  
%
Ripple & Noise (20 MHz) (Note 1)  
Ripple & Noise (20 MHz)  
Ripple & Noise (20 MHz)  
Output Power Protection  
Transient Response Time (Note 2)  
Transient Response Deviation  
Temperature Coefficient  
Output Short Circuit  
General  
mV P - P  
mV P - P  
mV rms  
%
100  
15  
120  
150  
2
500  
6
µS  
25% Load Step Change  
%
0.01  
0.02  
%/ºC  
RoHS Compliant  
Continuous (Autorecovery)  
Parameter  
Conditions  
Min.  
60 Seconds 1,500  
1,000 VDC 1,000  
100 kHz, 1V  
Typ.  
Max.  
Units  
VDC  
MΩ  
pF  
Isolation Voltage  
Isolation Resistance  
Isolation Capacitance  
Switching Frequency  
Environmental  
350  
300  
500  
kHz  
Parameter  
Conditions  
Min.  
Typ.  
Max.  
+71  
Units  
ºC  
ºC  
Operating Temperature Range  
Operating Temperature Range  
Storage Temperature Range  
Cooling  
Ambient  
Case  
-40  
-40  
-40  
+25  
+90  
+125  
ºC  
MicroPower Direct  
292 Page Street  
Suite D  
Free Air Convection  
RH, Non-condensing  
Humidity  
95  
%
Stoughton, MA 02072  
USA  
Physical  
Case Size  
1.27 x 0.58 x 0.40 Inches (32.3 x 14.8 x 10.2 mm)  
Non-Conductive Black Plastic (UL94-V0)  
0.31 Oz (8.8g)  
Case Material  
T: (781) 344-8226  
F: (781) 344-8481  
Weight  
E: sales@micropowerdirect.com Reliability Specifications  
W: www.micropowerdirect.com  
Parameter  
Conditions  
Min.  
Typ.  
Typ.  
Max.  
Units  
MTBF  
1.0  
MHours  
MIL HDBK 217F, 25ºC, Gnd Benign  
Absolute Maximum Ratings  
Parameter  
Conditions  
24 VDC Input  
Min.  
-0.7  
-0.7  
Max.  
50.0  
Units  
Input Voltage Surge (1 Sec)  
VDC  
48 VDC Input  
100.0  
260  
Lead Temperature  
1.5 mm From Case For 10 Sec.  
All Models  
ºC  
Internal Power Dissipation  
2,500  
mW  
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.  
Model Selection Guide  
Input  
Full-Load  
Output  
Current  
(mA, Max) (mA, Min)  
Fuse Rating  
Slow-Blow  
(mA)  
1,000  
1,000  
1,000  
1,000  
1,000  
1,000  
1,000  
500  
Reflected  
Ripple Cur.  
(mA)  
Model  
Efficiency  
(%, Typ)  
Voltage (VDC)  
Number  
Current (mA)  
Voltage  
(VDC)  
3.3  
Current  
Nominal  
24  
Range  
No-Load  
20  
LF301RU  
LF302RU  
LF303RU  
LF304RU  
LF305RU  
LF306RU  
LF307RU  
LF311RU  
LF312RU  
LF313RU  
LF314RU  
LF315RU  
LF316RU  
LF317RU  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
138  
158  
154  
154  
160  
154  
154  
68  
78  
75  
75  
78  
750  
600  
250  
200  
300  
125  
100  
750  
600  
250  
200  
300  
125  
100  
75.0  
60.0  
25.0  
27.0  
30.0  
12.5  
10.0  
75.0  
60.0  
25.0  
27.0  
30.0  
12.5  
10.0  
10  
10  
10  
10  
10  
10  
10  
5
5
5
5
5
75  
79  
81  
81  
78  
81  
81  
76  
80  
83  
83  
80  
83  
83  
24  
24  
24  
24  
24  
24  
48  
48  
48  
48  
48  
48  
20  
20  
20  
20  
20  
20  
10  
10  
10  
10  
10  
10  
5.0  
12.0  
15.0  
5.0  
12.0  
15.0  
3.3  
5.0  
500  
500  
500  
500  
500  
500  
12.0  
15.0  
5.0  
12.0  
15.0  
75  
75  
5
5
48  
10  
Notes:  
Derating Curve  
1. When measuring output ripple, it is recommended that an external 0.47 µF ceramic  
capacitor be placed from the +Vout pin to the -Vout pin for single output units and from  
each output to common for dual output units. For noise sensitive applications, the use of  
3.3 µF capacitors will reduce the output ripple.  
2. Transient recovery is measured to within a 1% error band for a load step change of 75%  
to 100%.  
3. No-load operation will not damage these units, however, they may not meet specifica-  
tions.  
4. Dual output units may provide a 10V, 24V or 30V output. To do this, connect the load  
across the positive (+Vout) and negative (-Vout) outputs and float the output common.  
5. The converter should be connected to a low ac-impedance source. An input source with  
a highly inductive impedance may affect the stability of the converter. In applications  
where the converter output loading is high and input power is supplied over long lines,  
it may be necessary to use a capacitor on the input to insure start-up. In this case, it is  
recommended that a low ESR (ESR <1.0Ω at 100 kHz) capacitor be mounted close to the  
converter. For 24V input units a 4.7 µF is recommended, and for 48V units a 2.2 µF.  
6. Maximum capacitive load for single output units is 3,000 µF, for dual output models it is  
180 µF for each output.  
7. It is recommended that a fuse be used on the input of a power supply for protection. See  
the table above for the correct rating.  
Mechanical Dimensions  
Remote ON/OFF  
Parameter  
Condition  
2.5 to 5.5 or Open Circuit  
-0.7 to 0.8  
10  
Referenced to Negative Input (-Vin)  
Units  
VDC  
VDC  
mA  
Supply On  
Supply Off  
Standby Input Current  
Control Common  
Remote ON/OFF Notes:  
1. Maximum sink current at the on/off pin (pin 1) during a logic  
low is 300 µA.  
2. Maximum allowable leakage current of a switch connected to the  
on/off terminal (Pin 1) at logic high (2.5V to 100V) is 200 µA.  
Board Layout  
Pin Connections  
Pin  
1
Single  
-Vin  
Dual  
-Vin  
-Vin  
2
-Vin  
3
On/Off On/Off  
10  
11  
12  
13  
14  
15  
22  
23  
24  
NC  
NC  
NC  
Common  
NC  
-Vout  
+Vout  
NC  
+Vout  
NC  
-Vout Common  
NC  
+Vin  
NC  
+Vin  
+Vin  
+Vin  
NC: No Connection  
Notes:  
All dimensions are typical in  
inches (mm)  
Tolerance x.xx = 0.01 ( 0.25)  
Pin 1 is marked by a “dot” or indentation on the unit  
MicroPower Direct  
www.micropowerdirect.com  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226  
FAX: (781) 344-8481  
E-Mail: sales@micropowerdirect.com  

相关型号:

LF303RW

Wide Input, 3W SMT Single & Dual Output DC/DC Converters
MPD

LF304RU

Very Wide Input, 3W SMT Single & Dual Output DC/DC Converters
MPD

LF304RW

Wide Input, 3W SMT Single & Dual Output DC/DC Converters
MPD

LF305-S

Current Transducer LF 305-S
LEM

LF305-S_06

Current Transducer
LEM

LF305RU

Very Wide Input, 3W SMT Single & Dual Output DC/DC Converters
MPD

LF305RW

Wide Input, 3W SMT Single & Dual Output DC/DC Converters
MPD

LF306RU

Very Wide Input, 3W SMT Single & Dual Output DC/DC Converters
MPD

LF306RW

Wide Input, 3W SMT Single & Dual Output DC/DC Converters
MPD

LF307RU

Very Wide Input, 3W SMT Single & Dual Output DC/DC Converters
MPD

LF307RW

Wide Input, 3W SMT Single & Dual Output DC/DC Converters
MPD

LF30AB

VERY LOW DROP VOLTAGE REGULATORS WITH INHIBIT
STMICROELECTR