B2011RW-R [MPD]

Analog Circuit;
B2011RW-R
型号: B2011RW-R
厂家: MICROPOWER DIRECT, LLC    MICROPOWER DIRECT, LLC
描述:

Analog Circuit

文件: 总2页 (文件大小:203K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
B2000RWSeries  
Compact 1 x 2 Inch 20W  
Wide Input Range  
DC/DC Converters  
Electrical Specifications  
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.  
Input  
Parameter  
Key Features:  
20W Output Power  
2:1 Input Voltage Range  
1,500 VDC Isolation  
Conditions  
12 VDC Input  
Min.  
8.6  
Typ.  
8.8  
17.5  
35.0  
Max.  
9.0  
18.0  
36.0  
Units  
Input Start Voltage  
24 VDC Input 17.0  
48 VDC Input 34.0  
VDC  
Input Filter  
π (Pi) Filter (Complies with EN55022 Class “A”)  
Compact 1 x 2 Inch Case  
Single & Dual Outputs  
Optional Remote ON/OFF  
Industry Standard Pin-Out  
Reverse Polarity Input Current  
Short Circuit Input Power  
Output  
2.0  
3,500  
A
mW  
Parameter  
Conditions  
Min.  
Typ.  
0.5  
0.5  
0.1  
0.1  
55  
Max.  
1.0  
2.0  
0.3  
0.5  
Units  
%
%
%
%
mV P - P  
mV P - P  
mV rms  
%
µSec  
%
Output Voltage Accuracy  
Output Voltage Balance  
Line Regulation  
Dual Output , Balanced Loads  
Vin = Min to Max  
Load Regulation  
Iout = 10% to 100%  
Ripple & Noise (20 MHz) (Note 1)  
Ripple & Noise (20 MHz)  
Ripple & Noise (20 MHz)  
Output Power Protection  
Transient Recovery Time (Note 2)  
Transient Response Deviation  
Temperature Coefficient  
Output Short Circuit  
General  
80  
Over Line, Load & Temp.  
25% Load Step Change  
100  
10  
160  
300  
4.0  
110  
150  
2.0  
0.01  
0.02  
%/°C  
Continuous (Autorecovery)  
RoHS Compliant  
Parameter  
Conditions  
Min.  
Typ.  
Max.  
Units  
VDC  
VDC  
MΩ  
pF  
Isolation Voltage  
Isolation Test Voltage  
Isolation Resistance  
Isolation Capacitance  
Switching Frequency  
Environmental  
60 Seconds 1,500  
Flash Tested For 1 Sec 1,650  
500 VDC 1,000  
100 kHz, 1V  
1,200 1,500  
290  
330  
360  
kHz  
Parameter  
Conditions  
Min.  
-40  
-40  
Typ.  
+25  
Max.  
+50  
+105  
+125  
Units  
°C  
°C  
Operating Temperature Range  
Operating Temperature Range  
Storage Temperature Range  
Cooling  
Ambient  
Case  
-50  
°C  
Free Air Convection  
RH, Non-condensing  
Humidity  
95  
%
MicroPower Direct  
292 Page Street  
Ste D  
Stoughton, MA 02072  
USA  
RFI  
Six-Side Shielded Metal Case  
EN55022 Class “A”  
Conducted EMI  
Physical  
Case Size  
Case Material  
Weight  
Reliability Specifications  
Parameter  
2.0 x 1.0 x 0.40 Inches (50.8 x 25.4 x 10.2 mm)  
Metal with Non-Conductive Base  
1.06 Oz (30g)  
T: (781) 344-8226  
F: (781) 344-8481  
E: sales@micropowerdirect.com  
W: www.micropowerdirect.com  
Conditions  
MIL HDBK 217F, 25°C, Gnd Benign  
Min.  
800  
Typ.  
Typ.  
Max.  
Units  
kHours  
MTBF  
Absolute Maximum Ratings  
Parameter  
Conditions  
Min.  
Max.  
25.0  
50.0  
100.0  
260.0  
4,500  
Units  
12 VDC Input -0.7  
24 VDC Input -0.7  
48 VDC Input -0.7  
Input Voltage Surge (1 Sec)  
VDC  
Lead Temperature  
Internal Power Dissipation  
1.5 mm From Case For 10 Sec  
All Models  
°C  
mW  
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.  
Model Selection Guide  
Over  
Voltage  
Protection (%, Typ)  
(VDC)  
Input  
Output  
Fuse Rating  
Slow-Blow  
(mA)  
Model  
Number  
Efficiency  
Reflected  
Voltage (VDC)  
Current (mA)  
Voltage Current  
(VDC) (mA, Max) (mA, Min)  
Current  
Ripple Current  
Nominal Range  
Full-Load No-Load  
(mA, Typ)  
B2001RW  
B2002RW  
B2003RW  
B2004RW  
B2005RW  
B2006RW  
B2011RW  
B2012RW  
B2013RW  
B2014RW  
B2015RW  
B2016RW  
B2021RW  
B2022RW  
B2023RW  
B2024RW  
B2025RW  
B2026RW  
12  
12  
12  
12  
12  
12  
24  
24  
24  
24  
24  
24  
48  
48  
48  
48  
48  
48  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
1,358  
1,984  
1,898  
1,903  
1,898  
1,903  
671  
980  
938  
941  
938  
941  
335  
490  
469  
471  
469  
471  
30  
30  
30  
30  
30  
30  
17  
17  
17  
17  
17  
17  
10  
10  
10  
10  
10  
10  
50  
50  
50  
50  
50  
50  
30  
30  
30  
30  
30  
30  
20  
20  
20  
20  
20  
20  
3.3  
5.0  
4,000.0  
4,000.0  
1,670.0  
1,340.0  
835.0  
240.0  
240.0  
100.0  
80.0  
50.0  
40.0  
240.0  
240.0  
100.0  
80.0  
50.0  
40.0  
240.0  
240.0  
100.0  
80.0  
50.0  
40.0  
3.9  
6.8  
81  
84  
88  
88  
88  
88  
82  
85  
89  
89  
89  
89  
82  
85  
89  
89  
89  
89  
4,000  
4,000  
4,000  
4,000  
4,000  
4,000  
2,000  
2,000  
2,000  
2,000  
2,000  
2,000  
1,000  
1,000  
1,000  
1,000  
1,000  
1,000  
12.0  
15.0  
12.0  
15.0  
3.3  
15.0  
18.0  
15.0  
18.0  
3.9  
670.0  
4,000.0  
4,000.0  
1,670.0  
1,340.0  
835.0  
5.0  
6.8  
12.0  
15.0  
12.0  
15.0  
3.3  
15.0  
18.0  
15.0  
18.0  
3.9  
670.0  
4,000.0  
4,000.0  
1,670.0  
1,340.0  
835.0  
5.0  
6.8  
12.0  
15.0  
12.0  
15.0  
15.0  
18.0  
15.0  
18.0  
670.0  
Notes:  
Derating Curve  
1. When measuring output ripple, it is recommended that an external 1.0 µF  
ceramic capacitor be placed from the +Vout pin to the -Vout pin for single  
output units and from each output to common for dual output units.  
2. Transient recovery is measured to within a 1% error band for a load step  
change of 75% to 100%.  
3. Operation at no-load will not damage these units. However, they may not  
meet all specifications.  
4. Dual output units may be connected to provide a 24 VDC or 30 VDC output.  
To do this, connect the load across the positive (+Vout) and negative (-Vout)  
outputs and float the output common.  
5. The converter should be connected to a low ac-impedance source. An  
input source with a highly inductive impedance may affect the stability of  
the converter. In applications where the converter output loading is high  
and input power is supplied over long lines, it may be necessary to use a  
capacitor on the input to insure start-up.  
In this case, it is recommended that a low ESR (ESR <1.0Ω at 100 kHz) ca-  
pacitor be mounted close to the converter. For 12V input units, a  
22.0 µF is recommended; for 24V & 48V units a 6.8 µF.  
6. It is recommended that a fuse be used on the input of a power supply for  
protection. See the table above for the correct rating.  
Remote ON/OFF (Optional, see below)  
Parameter  
Min  
2.5  
Max  
Units  
VDC  
VDC  
mA  
µA  
µA  
Mechanical Dimensions  
Supply On  
100 or Open  
Supply Off  
-1.0  
1.0  
5
5.0  
Standby Input Current  
Control Input Current (On)  
Control Input Current (Off)  
Control Common  
-100.0  
Referenced to Neg. Input (pin 2)  
Remote ON/OFF Notes:  
1. Maximum allowable leakage current of a switch connected to  
the on/off terminal (Pin 6) at logic high (2.5V to 100V) is 5 µA.  
Cap Load  
Single Output  
(µF Max)  
Pin Connections  
470  
Pin  
1
Single  
+Vin  
Dual  
+Vin  
Dual Output  
(µF Max)  
2
3
4
5
-Vin  
-Vin  
+Vout  
No Pin  
-Vout  
+Vout  
Common  
-Vout  
220  
6
Remote On/Off Remote On/Off  
For Remote On/Off Option, add suffix “R” to model number (i.e. B2003RW-R)  
Mechanical Notes:  
All dimensions are typical in inches (mm)  
Tolerance x.xx = 0.01 ( 0.25)  
MicroPower Direct  
www.micropowerdirect.com  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226  
FAX: (781) 344-8481  
E-Mail: sales@micropowerdirect.com  

相关型号:

B2012

ADSL & RADSLTransformers for Globespan Chipset - (11/98)
ETC

B201220006

Timers Interval
ETC

B201220060

Timers Interval
ETC

B201220600

Timers Interval
ETC

B2012RU

4:1 Input Range, 20W Single & Dual Output DC/DC Con vert ers
MPD

B2012RUI

Compact, High Isolation 4:1 Input Range, 20W DC/DC Converters
MPD

B2012RW

Compact 1 x 2 Inch 20W Wide Input Range DC/DC Con vert ers
MPD

B2012RW-F

Analog Circuit
MPD

B2012RW-R

Analog Circuit
MPD

B2013

BROADBAND ACCESS: xDSL, HPN, CMCs
PULSE

B2013FNL

COMMON MODE CHOKE 4LN SMD
PULSE

B2013FNLT

COMMON MODE CHOKE 4LN SMD
PULSE