B2012RU [MPD]

4:1 Input Range, 20W Single & Dual Output DC/DC Con vert ers; 4 : 1输入范围, 20W单和双输出DC / DC体质VERT器
B2012RU
型号: B2012RU
厂家: MICROPOWER DIRECT, LLC    MICROPOWER DIRECT, LLC
描述:

4:1 Input Range, 20W Single & Dual Output DC/DC Con vert ers
4 : 1输入范围, 20W单和双输出DC / DC体质VERT器

文件: 总4页 (文件大小:268K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
B2000RUSeries  
4:1 Input Range, 20W  
Single & Dual Output  
DC/DC Converters  
Electrical Specifications  
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.  
Input  
Key Features:  
Parameter  
Conditions  
24 VDC Input  
Min.  
9.0  
Typ.  
24.0  
48.0  
Max.  
36.0  
75.0  
Units  
20W Output Power  
4:1 Input Voltage Range  
Compact 1 x 2 Inch Case  
1,600 VDC Isolation  
High Efficiency  
Input Voltage Range  
VDC  
48 VDC Input 18.0  
Input Filter  
(Pi) Filter  
Input Reflected Ripple Current  
Output  
Parameter  
Output Voltage Accuracy  
Output Voltage Balance  
Line Regulation  
20.0  
mA P - P  
Conditions  
Min.  
Typ.  
1.0  
0.5  
Max.  
Units  
%
%
%
%
Single & Dual Outputs  
Remote ON/OFF  
Dual Output , Balanced Loads  
Vin = Min to Max  
0.5  
0.5  
1.0  
75  
Load Regulation, Single Output  
Load Regulation, Dual Output  
Ripple & Noise (20 MHz) (Note 1)  
Output Power Protection  
Transient Recovery Time (Note 2)  
Transient Response Deviation  
Temperature Coefficient  
Output Short Circuit Protection  
General  
Iout = 0% to 100%  
Iout = 0% to 100%  
Industry Standard Pin-Out  
%
mV P - P  
% IOUT  
µSec  
%
120  
250  
25% Load Step Change  
3.0  
0.02  
%/°C  
Continuous (Autorecovery)  
Parameter  
Conditions  
Min.  
3 Seconds 1,600  
3 Seconds 1,600  
500 VDC 1,000  
100 kHz, 1V  
Typ.  
Max.  
Units  
Isolation Voltage (Input/Output)  
Isolation Voltage (Case/Input(output)  
Isolation Resistance  
Isolation Capacitance  
Switching Frequency  
EMI Characteristics  
Parameter  
VDC  
M⍀  
pF  
kHz  
1,200  
330  
Standard  
Level  
Radiated Emissions  
Conducted Emissions (Note 3)  
ESD  
EN55022  
EN55022  
Class A  
Class A  
EN6100-4-2  
EN6100-4-3  
EN6100-4-4  
EN6100-4-5  
EN6100-4-6  
EN6100-4-8  
Criteria B  
Criteria A  
Criteria B  
Criteria B  
Criteria A  
Criteria A  
RS  
EFT (Note 4)  
Surge (Note 4)  
CS (Note 4)  
PFMF  
Environmental  
Parameter  
Conditions  
Min.  
-40  
Typ.  
+25  
Max.  
+66  
+105  
+125  
Units  
°C  
°C  
Operating Temperature Range  
Operating Temperature Range  
Storage Temperature Range  
Cooling  
Humidity  
RFI  
Ambient  
Case  
-40  
°C  
Free Air Convection  
RH, Non-condensing  
Six-Side Shielded Metal Case  
95  
%
MicroPower Direct  
292 Page Street  
Suite D  
Stoughton, MA 02072  
USA  
Physical  
Case Size  
Case Material  
Weight  
2.0 x 1.0 x 0.40 Inches (50.8 x 25.4 x 10.2 mm)  
Metal with Non-Conductive Base (UL94-V0)  
1.06 Oz (30g)  
Reliability Specifications  
T: (781) 344-8226  
F: (781) 344-8481  
E: sales@micropowerdirect.com  
W: www.micropowerdirect.com  
Parameter  
Conditions  
MIL HDBK 217F, 25°C, Gnd Benign  
Min.  
560  
Typ.  
Typ.  
Max.  
Units  
kHours  
MTBF  
Absolute Maximum Ratings  
Parameter  
Conditions  
Min.  
Max.  
50.0  
100.0  
260.0  
Units  
VDC  
°C  
24 VDC Input -0.7  
48 VDC Input -0.7  
1.5 mm From Case For 10 Sec  
Input Voltage Surge (1 Sec)  
Lead Temperature  
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.  
www.micropowerdirect.com  
Model Selection Guide  
www.micropowerdirect.com  
Input  
Output  
Over  
Voltage  
Protection  
(VDC)  
Max  
Capacitive  
Load  
Fuse Rating  
Slow-Blow  
(mA)  
Model  
Efficiency  
(%, Typ)  
Voltage (VDC)  
Number  
Current (mA)  
Voltage Current  
Current  
(VDC) (mA, Max) (mA, Min)  
(µF Max)  
Nominal Range Full-Load No-Load  
B2001RU  
B2002RU  
B2003RU  
B2004RU  
B2005RU  
B2006RU  
B2007RU  
B2011RU  
B2012RU  
B2013RU  
B2014RU  
B2015RU  
B2016RU  
B2017RU  
24  
24  
24  
24  
24  
24  
24  
48  
48  
48  
48  
48  
48  
48  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
879  
957  
980  
968  
968  
980  
980  
440  
413  
484  
484  
484  
490  
490  
50  
50  
22  
22  
65  
25  
25  
30  
30  
15  
15  
40  
15  
15  
3.3  
5.0  
5,500.0  
4,000.0  
1,670.0  
1,330.0  
2000.0  
835.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
3.9  
6.2  
89  
90  
88  
89  
89  
88  
88  
89  
91  
89  
89  
89  
88  
88  
2,000  
2,000  
2,000  
2,000  
2,000  
2,000  
2,000  
1,500  
1,500  
1,500  
1,500  
1,500  
1,500  
1,500  
10,000  
6,800  
1,000  
680  
12.0  
15.0  
5.0  
15.0  
18.0  
6.2  
2,200  
470  
12.0  
15.0  
3.3  
15.0  
18.0  
3.9  
665.0  
330  
5,500.0  
4,000.0  
1,670.0  
1,330.0  
2000.0  
835.0  
10,000  
6,800  
1,000  
680  
5.0  
6.2  
12.0  
15.0  
5.0  
15.0  
18.0  
6.2  
2,200  
470  
12.0  
15.0  
15.0  
18.0  
665.0  
330  
Notes:  
Recommended Input/Output Components  
1. Transient recovery is measured to within a 1% error band for a load step change of  
75% to 50% to 25%.  
2. Operation at no-load will not damage these units. However, they may not meet all  
specifications.  
3. Dual output units may be connected to provide a 10 VDC, 24 VDC or 30 VDC output.  
To do this, connect the load across the positive (+Vout) and negative (-Vout) outputs  
and float the output common.  
4. It is recommended that a fuse be used on the input of a power supply for protection.  
See the table above for the correct rating.  
Remote ON/OFF  
Parameter  
Min  
3.0  
0.0  
5 mA Typical  
Referenced to Neg. Input (pin 2)  
Max  
12 or Open VDC  
1.2 VDC  
Units  
Supply On  
Supply Off  
Standby Input Current  
Control Common  
To help meet EN55022 conducted emissions requirements, a simple Pi filter  
should be added externally to the input of the converter. Recommended  
components (C1, C2 & L1) are shown in the diagram above.These compo-  
nents should be mounted as close to the module as possible.  
To meet the requiremets of EN61000-4-4, EN61000-4-5 and EN61000-4-6,  
an external capacitor is required. It is recommended that the value shown in  
the figure above (C3) be used.  
When measuring output ripple, it is recommended that an external 1.0 µF  
ceramic capacitor be placed from the +Vout pin to the -Vout pin for single  
output units and from each output to common for dual output units. For  
noise sensitive applications, the use of 3.3 µF capacitors (as shown in the  
diagram above) will reduce the output ripple.  
A positive logic Remote On/Off input (Pin 6) can be used  
to control the converter. An open collector (or open  
drain) switch (Q1) is placed between the control input  
(Pin 6) and the -V Input (Pin 2).  
If not being used, the control input should be left open.  
Page 2  
Web: www.micropowerdirect.com Email: sales@micropowerdirect.com Tel: (781) 344 - 8226 Fax: (781) 344 - 8481  
B2000RU  
MicroPower  
Direct  
Series  
Output Trim (Single Output Models)  
A simple external circuit may be used to adjust Vout on  
single output models. To adjust the output DOWN, con-  
nect a 5%, 3W resistor between the plus output pin and  
the Vout trim pin. To adjust the output UP, connect a 5%,  
3W resistor between the minus output pin and the Vout  
trim pin. Resistor values are given in the chart below.  
For UP/Down trimming capability, connect a 10 kW poten-  
tiometer between the plus and minus outputs with the  
wiper arm connected to the Vout trim pin.  
Care should be taken that the maximum output power of  
the unit does not exceed the maximum rating.  
B2001RU, B2011RU  
Trim Down  
1
2
3
4
5
6
7
8
9
10  
%
VDC  
k⍀  
Vout =  
3.267  
3.234  
3.201  
3.168  
3.135  
3.102  
3.069  
3.036  
3.003  
2.970  
RTRIM Down =  
315.932 172.257 112.528 79.806 59.153 44.930 34.539 26.616 20.374 15.330  
Trim UP  
Vout =  
1
2
3
4
5
6
7
8
9
10  
%
VDC  
k⍀  
3.333  
3.366  
3.399  
3.432  
3.465  
3.498  
3.531  
3.564  
3.597  
3.630  
RTRIM Up =  
544.612 184.034 103.305 67.715 47.676 34.824 25.880 19.297 14.249 10.255  
B2002RU, B2012RU  
Trim Down  
1
2
3
4
5
6
7
8
9
10  
%
VDC  
k⍀  
Vout =  
4.950  
4.900  
4.850  
4.800  
4.750  
4.700  
4.650  
4.600  
4.550  
8.129  
4.500  
5.310  
RTRIM Down =  
230.566 106.182 64.301 43.281 30.643 22.207 16.177 11.651  
Trim UP  
Vout =  
1
2
3
4
5
6
7
8
9
10  
%
VDC  
k⍀  
5.050  
5.100  
5.150  
5.200  
5.250  
5.300  
5.350  
5.400  
5.450  
5.500  
RTRIM Up =  
244.547 113.776 70.631 49.142 36.274 27.707 21.592 17.010 13.447 10.598  
B2003RU, B2013RU  
Trim Down  
1
2
3
4
5
6
7
8
9
10  
%
VDC  
k⍀  
Vout =  
11.880 11.760 11.640 11.520 11.400 11.280 11.160 11.040 10.920 10.800  
RTRIM Down =  
327.351 142,100 83.928 55.470 38.591 27.418 19.477 13.542  
8.939  
9
5.264  
10  
Trim UP  
Vout =  
1
2
3
4
5
6
7
8
%
VDC  
k⍀  
12.120 12.240 12.360 12.480 12.600 12.720 12.840 12.960 13.080 13.200  
371.425 183.645 117.623 83.929 63.489 49.767 39.919 32.508 26.728 22.094  
RTRIM Up =  
B2004RU, B2014RU  
Trim Down  
1
2
3
4
5
6
7
8
9
10  
%
VDC  
k⍀  
Vout =  
14.850 14.700 14.550 14.400 14.250 14.100 13.950 13.800 13.650 13.500  
RTRIM Down =  
433.811 174.916 100.946 65,907 45.468 32.077 22.625 15.596 10.165  
5.842  
10  
Trim UP  
Vout =  
1
2
3
4
5
6
7
8
9
%
VDC  
k⍀  
15.150 15.300 15.450 15.600 15.750 15.900 16.050 16.200 16.350 16.500  
347.293 178.523 115.235 82.084 61.683 47.863 37.882 30.336 24.430 19.682  
RTRIM Up =  
Web: www.micropowerdirect.com Email: sales@micropowerdirect.com Tel: (781) 344 - 8226 Fax: (781) 344 - 8481  
Page 3  
Derating Curve  
www.micropowerdirect.com  
Pin Connections  
Pin  
Single  
Dual  
+Vin  
1
+Vin  
2
-Vin  
-Vin  
3
+Vout  
Trim  
+Vout  
Common  
-Vout  
4
5
-Vout  
6
Remote On/Off Remote On/Off  
Mechanical Dimensions  
Mechanical Notes:  
All dimensions are typical in inches (mm)  
Tolerance x.xx = 0.01 ( 0.25)  
MicroPower Direct  
www.micropowerdirect.com  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226  
FAX: (781) 344-8481  
E-Mail: sales@micropowerdirect.com  

相关型号:

B2012RUI

Compact, High Isolation 4:1 Input Range, 20W DC/DC Converters
MPD

B2012RW

Compact 1 x 2 Inch 20W Wide Input Range DC/DC Con vert ers
MPD

B2012RW-F

Analog Circuit
MPD

B2012RW-R

Analog Circuit
MPD

B2013

BROADBAND ACCESS: xDSL, HPN, CMCs
PULSE

B2013FNL

COMMON MODE CHOKE 4LN SMD
PULSE

B2013FNLT

COMMON MODE CHOKE 4LN SMD
PULSE

B2013NL

COMMON MODE CHOKE 4LN SMD
PULSE

B2013RU

4:1 Input Range, 20W Single & Dual Output DC/DC Con vert ers
MPD

B2013RUI

Compact, High Isolation 4:1 Input Range, 20W DC/DC Converters
MPD

B2013RW

Compact 1 x 2 Inch 20W Wide Input Range DC/DC Con vert ers
MPD

B2013RW-F

Analog Circuit
MPD