A300RU [MPD]

Single & Dual Output, 3W Ultra-Wide Input Range DC/DC Converters; 单,双输出, 3W超宽输入范围DC / DC转换器
A300RU
型号: A300RU
厂家: MICROPOWER DIRECT, LLC    MICROPOWER DIRECT, LLC
描述:

Single & Dual Output, 3W Ultra-Wide Input Range DC/DC Converters
单,双输出, 3W超宽输入范围DC / DC转换器

转换器
文件: 总2页 (文件大小:181K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
A300RU Series  
Single & Dual Output, 3W  
Ultra-Wide Input Range  
DC/DC Converters  
Electrical Specifications  
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.  
Input  
Key Features:  
Parameter  
Conditions  
24 VDC Input  
Min.  
6.0  
Typ.  
7.5  
15.0  
Max.  
9.0  
18.0  
8.5  
Units  
3W Output Power  
Input Start Voltage  
VDC  
48 VDC Input 12.0  
24 VDC Input  
48 VDC Input  
4:1 Input Voltage Range  
1,500 VDC Isolation  
EN60950 Compliant  
Meets EN55022 “A”  
Single & Dual Outputs  
1.0 MH MTBF  
Under Voltage Shutdown  
VDC  
16.0  
Input Filter  
(Pi) Filter (Meets EN55022 Class “A”)  
Reverse Polarity Input Current  
Short Circuit Input Power  
Output  
0.5  
A
mW  
2,000  
Industry Standard Pin-Out  
Parameter  
Conditions  
Min.  
Typ.  
0.5  
0.5  
0.2  
0.3  
40  
Max.  
2.0  
3.0  
1.0  
1.0  
75  
Units  
%
%
%
%
mV P - P  
mV P - P  
mV rms  
%
µSec  
%
Output Voltage Accuracy  
Output Voltage Balance  
Line Regulation  
Dual Output , Balanced Loads  
Vin = Min to Max  
Load Regulation  
Iout = 10% to 100%  
See Note 1  
Over Line, Load & Temp  
Ripple & Noise (20 MHz)  
Ripple & Noise (20 MHz)  
Ripple & Noise (20 MHz)  
Output Power Protection  
Transient Recovery Time (Note 2)  
Transient Response Deviation  
Temperature Coefficient  
Output Short Circuit  
General  
150  
15  
Vin = Min  
110  
150  
2.0  
0.01  
500  
25% Load Step Change  
0.02  
%/ºC  
Continuous (Autorecovery)  
Parameter  
Isolation Voltage  
Conditions  
Min.  
60 Seconds 1,500  
500 VDC 1,000  
100 kHz/1V  
Typ.  
Max.  
Units  
VDC  
M⍀  
pF  
Isolation Resistance  
Isolation Capacitance  
Switching Frequency  
Environmental  
Parameter  
Operating Temperature Range  
Operating Temperature Range  
Storage Temperature Range  
Cooling  
380  
350  
500  
kHz  
Conditions  
Min.  
Typ.  
Max.  
+71  
+90  
Units  
ºC  
ºC  
Ambient  
Case  
-40  
-55  
+125  
ºC  
Free Air Convection  
RH, Non-condensing  
Humidity  
95  
%
Physical  
Case Size  
Case Material  
Weight  
Reliability Specifications  
Parameter  
MicroPower Direct  
292 Page Street  
Suite D  
Stoughton, MA 02072  
USA  
1.25 x 0.80 x 0.40 Inches (31.8 x 20.3 x 10.2 mm)  
Non-Conductive Black Plastic (UL94V-0)  
0.42 Oz (12.2g)  
Conditions  
MIL HDBK 217F, 25ºC, Gnd Benign  
Min.  
1.0  
Typ.  
Typ.  
Max.  
Units  
MHours  
T: (781) 344-8226  
F: (781) 344-8481  
E: sales@micropowerdirect.com  
W: www.micropowerdirect.com  
MTBF  
Absolute Maximum Ratings  
Parameter  
Conditions  
Min.  
Max.  
50.0  
100.0  
260  
Units  
24 VDC Input -0.7  
48 VDC Input -0.7  
1.5 mm From Case For 10 Sec  
All Models  
Input Voltage Surge (1 Sec)  
VDC  
Lead Temperature  
Internal Power Dissipation  
ºC  
mW  
2,500  
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.  
www.micropowerdirect.com  
Model Selection Guide  
www.micropowerdirect.com  
Input  
Current (mA)  
Output  
Fuse Rating  
Slow-Blow  
(mA)  
Voltage (VDC)  
Model  
Reflected  
Ripple  
Efficiency  
(%, Typ)  
Voltage Current  
Current  
Number  
(VDC) (mA, Max) (mA, Min)  
Nominal  
Range  
Full-Load No-Load Current  
(mA, Typ)  
A301RU  
A302RU  
A303RU  
A304RU  
A305RU  
A306RU  
A311RU  
A312RU  
A313RU  
A314RU  
A315RU  
A316RU  
Notes:  
24  
24  
24  
24  
24  
24  
48  
48  
48  
48  
48  
48  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
138  
158  
154  
152  
156  
156  
68  
20  
20  
20  
20  
20  
20  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
3.3  
5.0  
750  
600  
250  
200  
125  
100  
750  
600  
250  
200  
125  
100  
93.0  
75.0  
32.0  
25.0  
16.0  
13.0  
93.0  
75.0  
32.0  
25.0  
16.0  
13.0  
75  
79  
81  
82  
80  
80  
76  
80  
83  
84  
82  
82  
1,000  
1,000  
1,000  
1,000  
1,000  
1,000  
500  
12.0  
15.0  
12.0  
15.0  
3.3  
78  
5.0  
500  
75  
12.0  
15.0  
12.0  
15.0  
500  
74  
500  
76  
500  
76  
500  
Derating Curve  
0. When measuring output ripple, it is recommended that an external ±.47 µF ceramic capacitor be  
placed from the +Vout pin to the -Vout pin for single output units and from each output to common  
for dual output units. For noise sensitive applications, the use of 3.3 µF capacitors will reduce the  
output ripple.  
2. Transient recovery is measured to within a 0% error band for a load step change of 75% to 0±±%.  
3. Operation at no-load will not damage these units. However, they may not meet all specifications.  
4. Dual output units may be connected to provide a 24 VDC or 3± VDC output. To do this, connect the  
load across the positive (+Vout) and negative (-Vout) outputs and float the output common.  
5. The converter should be connected to a low ac-impedance source. An input source with a highly  
inductive impedance may affect the stability of the converter. In applications where the converter  
output loading is high and input power is supplied over long lines, it may be necessary to use a  
capacitor on the input to insure start-up.  
In this case, it is recommended that a low ESR (ESR <0.±at 0±± kHz) capacitor be mounted  
close to the converter. For 24V input units a 4.7 µF is recommended; and for 48V units a 2.2 µF.  
6. It is recommended that a fuse be used on the input of a power supply for protection. See the table  
above for the correct rating.  
Capacitive Load  
Maximum  
Load  
Maximum  
Load  
Vout  
Vout  
Capacitance  
Capacitance  
Mechanical Dimensions  
3.3 VDC  
5 VDC  
12 VDC  
15 VDC  
680 µF  
470 µF  
330 µF  
220 µF  
±12 VDC  
±15 VDC  
150 µF  
100 µF  
Pin Connections  
Pin  
2, 3  
Single  
-Vin  
Dual  
-Vin  
9
11  
No Pin  
NC  
Common  
-Vout  
14  
+Vout  
-Vout  
+Vin  
+Vout  
16  
Common  
+Vin  
22, 23  
NC: No Connection  
Mechanical Notes:  
All dimensions are typical in inches (mm)  
Tolerance x.xx = ±±.±0 (±±.25)  
MicroPower Direct  
We Power Your Success - For Less!  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226  
FAX: (781) 344-8481  
E-Mail: sales@micropowerdirect.com  

相关型号:

A300RUI

3W, Ultra-Wide Input High Isolation DC/DC Converters
MPD

A300RW

Wide Input Range, 3W Single & Dual Output DC/DC Converters
MPD

A301-100

100W Modified Sine Wave DC-AC Power Inverter
MEANWELL

A301-100-F3

100W Modified Sine Wave DC-AC Power Inverter
MEANWELL

A301-150-B2

150W Modified Sine Wave DC-AC Power Inverter
MEANWELL

A301-1K0-B2

1000W Modified Sine Wave DC-AC Power Inverter
MEANWELL

A301-1K0-F3

1000W Modified Sine Wave DC-AC Power Inverter
MEANWELL

A301-1K7-B2

1500W Modified Sine Wave DC-AC Power Inverter
MEANWELL

A301-1K7-F3

1500W Modified Sine Wave DC-AC Power Inverter
MEANWELL

A301-2K5-B4

2500W Modified Sine Wave DC-AC Power Inverter
MEANWELL

A301-2K5-F3

2500W Modified Sine Wave DC-AC Power Inverter
MEANWELL

A301-300-B2

300W Modified Sine Wave DC-AC Power Inverter
MEANWELL