A300RUI [MPD]

3W, Ultra-Wide Input High Isolation DC/DC Converters; 3W ,超宽输入高隔离的DC / DC转换器
A300RUI
型号: A300RUI
厂家: MICROPOWER DIRECT, LLC    MICROPOWER DIRECT, LLC
描述:

3W, Ultra-Wide Input High Isolation DC/DC Converters
3W ,超宽输入高隔离的DC / DC转换器

转换器
文件: 总2页 (文件大小:89K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MicroPower  
Direct  
3W, Ultra-Wide Input  
Key Features  
High Isolation  
4:1 Input Range  
3W Output Power  
3.5 kVDC I/O Isolation  
Single & Dual Outputs  
DC/DC Converters  
A300RUI Series  
Tight Line/Load Regulation Low Cost  
Electrical Specifications  
Specifications typical @ +251C with nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.  
Input  
Parameter  
Conditions  
24 VDC Input  
48 VDC Input  
Min.  
4.5  
8.5  
Typ.  
6.0  
12.0  
Max.  
8.5  
17.0  
Units  
Input Start Voltage  
VDC  
Input Filter  
π (Pi) Filter  
Short Circuit Input Power  
2,000  
mW  
Output  
Parameter  
Output Voltage Accuracy  
Output Voltage Balance  
Line Regulation  
Load Regulation  
Ripple & Noise (20 MHz)  
Output Power Protection  
Transient Recovery Time (Note 1)  
Transient Response Deviation  
Temperature Coefficient  
Output Short Circuit  
General  
Conditions  
Min.  
Typ.  
!0.5  
!0.5  
!0.2  
!0.2  
Max.  
!1.0  
!1.0  
!0.5  
!0.5  
60  
Units  
%
%
%
%
mV P - P  
%
µSec  
%
Dual Output , Balanced Loads  
Vin = Min to Max  
Iout = 10% to 100%  
120  
150  
500  
25% Load Step Change  
!2.0  
!0.01 !0.02  
%/1C  
Continuous  
Min.  
60 Seconds 3,500  
500 VDC 1,000  
100 kHz, 1V  
Parameter  
Conditions  
Typ.  
Max.  
Units  
VDC  
MΩ  
pF  
mA  
Isolation Voltage  
Isolation Resistance  
Isolation Capacitance  
Leakage Current  
Switching Frequency  
Environmental  
Parameter  
Operating Temperature Range  
Storage Temperature Range  
Cooling  
390  
1.0  
300  
kHz  
Conditions  
Min.  
-40  
-40  
Typ.  
Max.  
+85  
+125  
Units  
1C  
1C  
Free Air Convection  
Humidity  
RH, Non-condensing  
90  
%
Physical  
Case Size  
Case Material  
Weight  
1.25 x 0.80 x 0.40 Inches (31.8 x 20.3 x 10.2 mm)  
Metal with Non-Conductive Base  
0.74 Oz (21g)  
Reliability Specifications  
Parameter  
MTBF  
Conditions  
MIL HDBK 217F, 251C, Gnd Benign  
Min.  
950  
Typ.  
Typ.  
Max.  
Units  
kHours  
Absolute Maximum Ratings  
Parameter  
Conditions  
24 VDC Input  
48 VDC Input  
All Models  
Min.  
-0.7  
-0.7  
Max.  
50.0  
100.0  
2,500  
Units  
VDC  
mW  
Input Voltage Surge (1 Sec)  
Internal Power Dissipation  
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.  
MicroPower Direct TEL: (781) 344-8226 FAX: (781) 344-8481 E-Mail: sales@micropowerdirect.com WEB: www/micropowerdirect.com  
Model Selection Guide  
Input  
Current (mA)  
Output  
Fuse Rating  
Slow-Blow  
(mA)  
Voltage (VDC)  
Model  
Reflected  
Ripple  
Current  
(mA, Typ)  
Efficiency  
(%, Typ)  
Voltage Current  
(VDC) (mA, Max) (mA, Min)  
Current  
Number  
Nominal  
Range  
Full-Load No-Load  
A301RUI  
A302RUI  
A303RUI  
A304RUI  
A305RUI  
A306RUI  
A311RUI  
A312RUI  
A313RUI  
A314RUI  
A315RUI  
A316RUI  
24  
24  
24  
24  
24  
24  
48  
48  
48  
48  
48  
48  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
18.0 - 72.0  
18.0 - 72.0  
18.0 - 72.0  
18.0 - 72.0  
18.0 - 72.0  
18.0 - 72.0  
166  
158  
158  
166  
158  
158  
83  
80  
79  
83  
80  
12  
12  
12  
12  
12  
12  
7
7
7
7
7
5
5
5
5
5
5
5
5
5
5
5
5
5.0  
12.0  
15.0  
!5.0  
!12.0  
!15.0  
5.0  
12.0  
15.0  
!5.0  
!12.0  
!15.0  
600  
250  
200  
60.0  
25.0  
20.0  
75  
79  
79  
75  
79  
79  
75  
78  
78  
76  
79  
79  
1,000  
1,000  
1,000  
1,000  
1,000  
1,000  
500  
500  
500  
500  
500  
!300  
!125  
!100  
600  
250  
200  
!30.0  
!12.0  
!10.0  
60.0  
25.0  
20.0  
!300  
!125  
!100  
!30.0  
!12.0  
!10.0  
80  
7
500  
Notes: 1. Transient recovery is measured to within a 1% error band for a load step change of 75% tp 100%.  
2. Dual output units may be connected to provide a 10V, 24V or 30V output. To do this connect the load across the  
positive (+Vout) and negative (-Vout) outputs and float the output common.  
Derating Curve  
Capacitive Load  
Single Output Dual Output  
F Max)  
F Max)  
1,000  
!220  
-5%/1C  
Ambient Temperature ( C)  
Mechanical Dimensions  
Pin Connections  
Pin  
2, 3  
9
Single  
-Vin  
Dual  
-Vin  
0.18  
(4.6)  
23  
22  
2
3
No Pin  
NC  
Common  
-Vout  
11  
0.10  
(2.54)  
14  
+Vout  
-Vout  
+Vin  
+Vout  
Common  
+Vin  
1.25  
(31.8)  
16  
Bottom  
Side  
22, 23  
16  
14  
9
NC: No Connection  
0.02 DIA  
(0.5)  
11  
Notes:  
All dimensions are typical in inches (mm)  
Tolerance x.xx = !0.01 (!0.25)  
0.60  
(15.2)  
0.10  
(2.54)  
0.15  
(3.8)  
Pin 1 is marked by a “dot” or indentation on the top of the unit  
0.80  
(20.3)  
0.40  
(10.2)  
232 Tosca Drive, Stoughton, MA 02072  
www.micropowerdirect.com  
MicroPower  
Direct  
sales@micropowerdirect.com  
phone: (781) 344 - 8226 * fax: (781) 344 - 8481  

相关型号:

A300RW

Wide Input Range, 3W Single & Dual Output DC/DC Converters
MPD

A301-100

100W Modified Sine Wave DC-AC Power Inverter
MEANWELL

A301-100-F3

100W Modified Sine Wave DC-AC Power Inverter
MEANWELL

A301-150-B2

150W Modified Sine Wave DC-AC Power Inverter
MEANWELL

A301-1K0-B2

1000W Modified Sine Wave DC-AC Power Inverter
MEANWELL

A301-1K0-F3

1000W Modified Sine Wave DC-AC Power Inverter
MEANWELL

A301-1K7-B2

1500W Modified Sine Wave DC-AC Power Inverter
MEANWELL

A301-1K7-F3

1500W Modified Sine Wave DC-AC Power Inverter
MEANWELL

A301-2K5-B4

2500W Modified Sine Wave DC-AC Power Inverter
MEANWELL

A301-2K5-F3

2500W Modified Sine Wave DC-AC Power Inverter
MEANWELL

A301-300-B2

300W Modified Sine Wave DC-AC Power Inverter
MEANWELL

A301-300-F3

300W Modified Sine Wave DC-AC Power Inverter
MEANWELL