MIZI03-110D15 [MINMAX]

DC-DC CONVERTER 3W;
MIZI03-110D15
型号: MIZI03-110D15
厂家: MINMAX TECHNOLOGY CO., LTD.    MINMAX TECHNOLOGY CO., LTD.
描述:

DC-DC CONVERTER 3W

DC-DC转换器
文件: 总5页 (文件大小:460K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
®
MIZI03 SERIES  
DC-DC CONVERTER 3W, Railway Certified  
FEATURES  
Industrial Standard DIP-24 Package  
Ultra-wide Input Ranges 9-36VDC, 18-75VDC, 40-160VDC  
I/O Isolation 3000VAC with Reinforced Insulation  
Operating Ambient Temp. Range -40to +92℃  
No Min. Load Requirement  
Under-Voltage, Overload and Short Circuit Protection  
EMI Emission EN 55032/11 Class A & FCC Level A Approved  
Vibration and Shock/Bump Test EN 61373 Approved  
Cooling, Dry & Damp Heat Test IEC/EN 60068-2-1, 2, 30 Approved  
Railway EMC Standard EN 50121-3-2 Approved  
Railway Certified EN 50155 (IEC60571) Approved  
Fire Protection Test EN 45545-2 Approved  
UL/cUL/IEC/EN 62368-1 (60950-1) Safety Approval & CE Marking  
PRODUCT OVERVIEW  
The MINMAX MIZI03 series is a new range of railway approved 3W isolated DC-DC converter within encapsulated DIP-24 package which specifically  
design for railway applications. There are 15 models available for railway input voltage of either 24(9~36)VDC or 48(18~75)VDC or 72/110(40~160)VDC  
and tight output voltage regulation.  
Further features include high I/O isolation rated for 3000VAC with reinforced insulation, overload, under-voltage and short circuit protection and conducted  
EMI EN 55032/11 class A & FCC level A approved as well. MIZI03 series conform to vibration and shock/bump test EN 61373, cooling, dry and damp heat  
test IEC/EN 60068-2-1,2,30 and railway EMC standard EN 50121-3-2 and complies also with Railway Certification EN 50155 (IEC60571) and EN 45545-2  
for fire protection test.  
MIZI03 series offer an highly reliable solution for critical applications in railway systems, battery-powered equipment, measure instrumentation and many  
critical applications.  
Model Selection Guide  
Model  
Input  
Voltage  
(Range)  
VDC  
Output  
Output Current  
Input Current  
Max. capacitive  
Load  
Efficiency  
Number  
Voltage  
(typ.)  
@Max. Load  
@No Load  
mA(typ.)  
Max.  
mA  
@Max. Load  
VDC  
5
mA(typ.)  
156  
149  
147  
151  
149  
78  
μF  
%
MIZI03-24S05  
MIZI03-24S12  
MIZI03-24S15  
MIZI03-24D12  
MIZI03-24D15  
MIZI03-48S05  
MIZI03-48S12  
MIZI03-48S15  
MIZI03-48D12  
MIZI03-48D15  
MIZI03-110S05  
MIZI03-110S12  
MIZI03-110S15  
MIZI03-110D12  
MIZI03-110D15  
600  
680  
80  
84  
85  
83  
84  
80  
83  
84  
83  
83  
80  
84  
84  
83  
85  
12  
250  
330  
24  
(9 ~ 36)  
15  
200  
9
5
3
220  
±12  
±15  
5
±125  
±100  
600  
220#  
220#  
680  
12  
250  
75  
330  
48  
(18 ~ 75)  
15  
200  
74  
220  
±12  
±15  
5
±125  
±100  
600  
75  
220#  
75  
220#  
34  
680  
12  
250  
32  
330  
220  
110  
(40 ~ 160)  
15  
200  
32  
±12  
±15  
±125  
±100  
33  
220#  
32  
220#  
# For each output  
E-mail:sales@minmax.com.tw Tel:886-6-2923150  
2018/08/31 REV:4 Page 1 of 5  
®
MIZI03 SERIES  
DC-DC CONVERTER 3W, Railway Certified  
Input Specifications  
Parameter  
Model  
24V Input Models  
Min.  
-0.7  
-0.7  
-0.7  
---  
Typ.  
---  
Max.  
50  
100  
170  
9
Unit  
Input Surge Voltage (1 sec. max.)  
Start-Up Threshold Voltage  
Under Voltage Shutdown  
48V Input Models  
---  
110V Input Models  
24V Input Models  
---  
---  
48V Input Models  
---  
---  
18  
40  
---  
VDC  
110V Input Models  
24V Input Models  
---  
---  
---  
7.5  
16  
37  
---  
48V Input Models  
---  
---  
110V Input Models  
Nominal Vin and Constant Resistive Load  
All Models  
---  
---  
Start Up Time (Power On)  
Input Filter  
---  
60  
ms  
Internal Pi Type  
Output Specifications  
Parameter  
Output Voltage Setting Accuracy  
Output Voltage Balance  
Line Regulation  
Conditions / Model  
Min.  
Typ.  
Max.  
Unit  
---  
---  
---  
---  
---  
---  
±1  
---  
---  
---  
±1.0  
±2.0  
±0.5  
±1.0  
±5.0  
%
%
%
%
%
Dual Output, Balanced Loads  
Vin=Min. to Max. @Full Load  
Io=0% to 100%  
Load Regulation  
Load Cross Regulation (Dual Output Models)  
Minimum Load  
Asymmetrical Load 25/100% Full Load  
No minimum Load Requirement  
0-20 MHz  
Bandwidth  
5Vo  
Measured with a  
---  
---  
---  
---  
---  
---  
50  
75  
---  
---  
---  
mV P-P  
mV P-P  
μsec  
%
Ripple & Noise  
12V,15V, ±12, ±15Vo  
10μF/25V MLCC  
Transient Recovery Time  
Transient Response Deviation  
Temperature Coefficient  
Over Load Protection  
500  
±5  
25% Load Step Change(2)  
±3  
---  
±0.02  
---  
%/  
%
Hiccup  
150  
Short Circuit Protection  
Hiccup Mode 0.7Hz typ., Automatic Recovery  
General Specifications  
Parameter  
I/O Isolation Voltage  
Conditions  
Reinforced Insulation, Rated For 60 Seconds  
Min.  
3000  
1000  
---  
Typ.  
Max.  
---  
Unit  
VACrms  
MΩ  
---  
---  
I/O Isolation Resistance  
I/O Isolation Capacitance  
500 VDC  
100KHz, 1V  
---  
1500  
170  
285  
---  
---  
pF  
110Vin Models  
---  
---  
kHz  
Switching Frequency  
MTBF(calculated)  
Safety Approval  
Other Models  
---  
---  
kHz  
MIL-HDBK-217F@25, Ground Benign  
UL/cUL 60950-1 recognition (UL certificate), IEC/EN 60950-1(CB-report), EN 50155, IEC 60571  
3,360,000  
---  
Hours  
UL/cUL 62368-1 recognition (UL certificate), IEC/EN 62368-1 (CB-report)  
Environmental Specifications  
Parameter  
Operating Ambient Temperature Range  
(See Power Derating Curve)  
Case Temperature  
Conditions  
Min.  
-40  
Max.  
+92  
Unit  
---  
+105  
+125  
Storage Temperature Range  
Cooling Test  
-50  
Compliance to IEC/EN 60068-2-1  
Compliance to IEC/EN 60068-2-2  
Compliance to IEC/EN 60068-2-30  
Compliance to IEC/EN 61373  
---  
Dry Heat  
Damp Heat  
Shock & Vibration Test  
Humidity (non condensing)  
95  
% rel. H  
Lead Temperature (1.5mm from case for 10Sec.)  
---  
260  
E-mail:sales@minmax.com.tw Tel:886-6-2923150  
2018/08/31 REV:4  
Page 2 of 5  
®
MIZI03 SERIES  
DC-DC CONVERTER 3W, Railway Certified  
EMC Specifications  
Parameter  
General  
EMI  
Standards & Level  
Performance  
Compliance with EN 50121-3-2 Railway Applications  
EN 55032, EN 55011, FCC part 15  
Conduction & Radiation  
EN 55024  
Class A  
ESD  
EN 61000-4-2 Air ± 8kV, Contact ± 6kV  
EN 61000-4-3 10V/m  
A
A
A
A
A
A
Radiated immunity  
Fast transient(4)  
Surge(4)  
EN 61000-4-4 ±2kV  
EMS  
EN 61000-4-5 ±2kV  
Conducted immunity  
PFMF  
EN 61000-4-6 10Vrms  
EN 61000-4-8 3A/M  
Power Derating Curve  
Notes  
1
2
3
4
Specifications typical at Ta=+25, resistive load, nominal input voltage and rated output current unless otherwise noted.  
Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%.  
We recommend to protect the converter by a slow blow fuse in the input supply line.  
To meet EN 61000-4-4 & EN 61000-4-5 an external capacitor across the input pins is required.  
Suggested capacitor: 24XXX: CHEMI-CON KY Series 470μF/50V.  
48XXX: CHEMI-CON KY Series 330μF/100V.  
110XXX: CHEMI-CON KXG Series 220μF/250V.  
5
6
Other input and output voltage may be available, please contact factory.  
Specifications are subject to change without notice.  
E-mail:sales@minmax.com.tw Tel:886-6-2923150  
2018/08/31 REV:4 Page 3 of 5  
®
MIZI03 SERIES  
DC-DC CONVERTER 3W, Railway Certified  
Package Specifications  
Mechanical Dimensions  
Pin Connections  
Pin  
1
Single Output  
+Vin  
Dual Output  
+Vin  
11  
12  
13  
15  
23  
24  
No Pin  
-Vout  
Common  
No Pin  
-Vout  
+Vout  
No Pin  
-Vin  
+Vout  
0.60 [0.024]  
-Vin  
-Vin  
-Vin  
1
11 12  
Bottom View  
24 23  
15  
13  
All dimensions in mm (inches)  
Tolerance: X.X±0.5 (X.XX±0.02)  
20.32 [0.80]  
31.8 [1.25]  
5.08  
[0.20]  
2.0  
[0.08]  
2.54  
[0.10]  
X.XX±0.25 ( X.XXX±0.01)  
Pin diameter 0.6 ±0.05 (0.024±0.002)  
Physical Characteristics  
Case Size  
Case Material  
Pin Material  
Weight  
:
:
:
:
31.8x20.3x12.0mm (1.25x0.8x0.47 inches)  
Non-Conductive Black Plastic (flammability to UL 94V-0 rated)  
Tinned Copper  
15.4g  
E-mail:sales@minmax.com.tw Tel:886-6-2923150  
2018/08/31 REV:4 Page 4 of 5  
®
MIZI03 SERIES  
DC-DC CONVERTER 3W, Railway Certified  
Test Setup  
Peak-to-Peak Output Noise Measurement Test  
Refer to the output specifications or add 4.7μF capacitor if the output specifications undefine Cout. Scope measurement should be made by using a BNC socket,  
measurement bandwidth is 0-20 MHz. Position the load between 50 mm and 75 mm from the DC-DC Converter.  
Copper Strip  
Cout  
+Vin  
+Out  
Copper Strip  
+Vin  
+Out  
Com.  
-Out  
Scope  
Scope  
Single Output  
DC / DC  
Converter  
Dual Output  
DC / DC  
Converter  
Resistive  
Load  
Resistive  
Load  
Cout  
Scope  
Copper Strip  
Cout  
-Vin  
-Out  
Copper Strip  
-Vin  
Copper Strip  
Technical Notes  
Overload Protection  
To provide hiccup mode protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure overload for an  
unlimited duration.  
Input Source Impedance  
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module.  
In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup.  
Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR < 1.0  
Ω at 100 kHz) capacitor of 4.7μF for the 24V input devices, a 2.2μF for the 48V devices and a 1μF for the 110V devices.  
+
+Vin  
+Out  
+
DC / DC  
Converter  
DC Power  
Source  
Load  
Cin  
-
-Vin  
-Out  
Output Ripple Reduction  
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is  
recommended to use 4.7μF capacitors at the output.  
+
+Vin  
+Out  
+
+Vin  
-Vin  
+Out  
Load  
Load  
Single Output  
DC / DC  
Converter  
Dual Output  
Cout  
Cout  
DC Power  
Source  
DC Power  
Source  
DC / DC Com.  
Converter  
Cout  
Load  
-
-Vin  
-Out  
-
-Out  
Maximum Capacitive Load  
The MIZI03 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up,  
affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet.  
Thermal Considerations  
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the  
maximum temperature rating of the components inside the power module, the case temperature must be kept below 105. The derating curves are determined from  
measurements obtained in a test setup.  
Position of air velocity  
probe and thermocouple  
Air Flow  
50mm / 2in  
15mm / 0.6in  
DUT  
Minmax Technology Co., Ltd.  
18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan  
Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: sales@minmax.com.tw  
2018/08/31 REV:4  
Page 5 of 5  

相关型号:

MIZI03-110S05

DC-DC CONVERTER 3W
MINMAX

MIZI03-110S12

DC-DC CONVERTER 3W
MINMAX

MIZI03-110S15

DC-DC CONVERTER 3W
MINMAX

MIZI03-24D12

DC-DC CONVERTER 3W
MINMAX

MIZI03-24D15

DC-DC CONVERTER 3W
MINMAX

MIZI03-24S05

DC-DC CONVERTER 3W
MINMAX

MIZI03-24S12

DC-DC CONVERTER 3W
MINMAX

MIZI03-24S15

DC-DC CONVERTER 3W
MINMAX

MIZI03-48D12

DC-DC CONVERTER 3W
MINMAX

MIZI03-48D15

DC-DC CONVERTER 3W
MINMAX

MIZI03-48S05

DC-DC CONVERTER 3W
MINMAX

MIZI03-48S12

DC-DC CONVERTER 3W
MINMAX