MIZI03-48D15 [MINMAX]
DC-DC CONVERTER 3W;型号: | MIZI03-48D15 |
厂家: | MINMAX TECHNOLOGY CO., LTD. |
描述: | DC-DC CONVERTER 3W DC-DC转换器 |
文件: | 总5页 (文件大小:460K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
®
MIZI03 SERIES
DC-DC CONVERTER 3W, Railway Certified
FEATURES
►Industrial Standard DIP-24 Package
►Ultra-wide Input Ranges 9-36VDC, 18-75VDC, 40-160VDC
►I/O Isolation 3000VAC with Reinforced Insulation
►Operating Ambient Temp. Range -40℃ to +92℃
►No Min. Load Requirement
►Under-Voltage, Overload and Short Circuit Protection
►EMI Emission EN 55032/11 Class A & FCC Level A Approved
►Vibration and Shock/Bump Test EN 61373 Approved
►Cooling, Dry & Damp Heat Test IEC/EN 60068-2-1, 2, 30 Approved
►Railway EMC Standard EN 50121-3-2 Approved
►Railway Certified EN 50155 (IEC60571) Approved
►Fire Protection Test EN 45545-2 Approved
►UL/cUL/IEC/EN 62368-1 (60950-1) Safety Approval & CE Marking
PRODUCT OVERVIEW
The MINMAX MIZI03 series is a new range of railway approved 3W isolated DC-DC converter within encapsulated DIP-24 package which specifically
design for railway applications. There are 15 models available for railway input voltage of either 24(9~36)VDC or 48(18~75)VDC or 72/110(40~160)VDC
and tight output voltage regulation.
Further features include high I/O isolation rated for 3000VAC with reinforced insulation, overload, under-voltage and short circuit protection and conducted
EMI EN 55032/11 class A & FCC level A approved as well. MIZI03 series conform to vibration and shock/bump test EN 61373, cooling, dry and damp heat
test IEC/EN 60068-2-1,2,30 and railway EMC standard EN 50121-3-2 and complies also with Railway Certification EN 50155 (IEC60571) and EN 45545-2
for fire protection test.
MIZI03 series offer an highly reliable solution for critical applications in railway systems, battery-powered equipment, measure instrumentation and many
critical applications.
Model Selection Guide
Model
Input
Voltage
(Range)
VDC
Output
Output Current
Input Current
Max. capacitive
Load
Efficiency
Number
Voltage
(typ.)
@Max. Load
@No Load
mA(typ.)
Max.
mA
@Max. Load
VDC
5
mA(typ.)
156
149
147
151
149
78
μF
%
MIZI03-24S05
MIZI03-24S12
MIZI03-24S15
MIZI03-24D12
MIZI03-24D15
MIZI03-48S05
MIZI03-48S12
MIZI03-48S15
MIZI03-48D12
MIZI03-48D15
MIZI03-110S05
MIZI03-110S12
MIZI03-110S15
MIZI03-110D12
MIZI03-110D15
600
680
80
84
85
83
84
80
83
84
83
83
80
84
84
83
85
12
250
330
24
(9 ~ 36)
15
200
9
5
3
220
±12
±15
5
±125
±100
600
220#
220#
680
12
250
75
330
48
(18 ~ 75)
15
200
74
220
±12
±15
5
±125
±100
600
75
220#
75
220#
34
680
12
250
32
330
220
110
(40 ~ 160)
15
200
32
±12
±15
±125
±100
33
220#
32
220#
# For each output
E-mail:sales@minmax.com.tw Tel:886-6-2923150
2018/08/31 REV:4 Page 1 of 5
®
MIZI03 SERIES
DC-DC CONVERTER 3W, Railway Certified
Input Specifications
Parameter
Model
24V Input Models
Min.
-0.7
-0.7
-0.7
---
Typ.
---
Max.
50
100
170
9
Unit
Input Surge Voltage (1 sec. max.)
Start-Up Threshold Voltage
Under Voltage Shutdown
48V Input Models
---
110V Input Models
24V Input Models
---
---
48V Input Models
---
---
18
40
---
VDC
110V Input Models
24V Input Models
---
---
---
7.5
16
37
---
48V Input Models
---
---
110V Input Models
Nominal Vin and Constant Resistive Load
All Models
---
---
Start Up Time (Power On)
Input Filter
---
60
ms
Internal Pi Type
Output Specifications
Parameter
Output Voltage Setting Accuracy
Output Voltage Balance
Line Regulation
Conditions / Model
Min.
Typ.
Max.
Unit
---
---
---
---
---
---
±1
---
---
---
±1.0
±2.0
±0.5
±1.0
±5.0
%
%
%
%
%
Dual Output, Balanced Loads
Vin=Min. to Max. @Full Load
Io=0% to 100%
Load Regulation
Load Cross Regulation (Dual Output Models)
Minimum Load
Asymmetrical Load 25/100% Full Load
No minimum Load Requirement
0-20 MHz
Bandwidth
5Vo
Measured with a
---
---
---
---
---
---
50
75
---
---
---
mV P-P
mV P-P
μsec
%
Ripple & Noise
12V,15V, ±12, ±15Vo
10μF/25V MLCC
Transient Recovery Time
Transient Response Deviation
Temperature Coefficient
Over Load Protection
500
±5
25% Load Step Change(2)
±3
---
±0.02
---
%/℃
%
Hiccup
150
Short Circuit Protection
Hiccup Mode 0.7Hz typ., Automatic Recovery
General Specifications
Parameter
I/O Isolation Voltage
Conditions
Reinforced Insulation, Rated For 60 Seconds
Min.
3000
1000
---
Typ.
Max.
---
Unit
VACrms
MΩ
---
---
I/O Isolation Resistance
I/O Isolation Capacitance
500 VDC
100KHz, 1V
---
1500
170
285
---
---
pF
110Vin Models
---
---
kHz
Switching Frequency
MTBF(calculated)
Safety Approval
Other Models
---
---
kHz
MIL-HDBK-217F@25℃, Ground Benign
UL/cUL 60950-1 recognition (UL certificate), IEC/EN 60950-1(CB-report), EN 50155, IEC 60571
3,360,000
---
Hours
UL/cUL 62368-1 recognition (UL certificate), IEC/EN 62368-1 (CB-report)
Environmental Specifications
Parameter
Operating Ambient Temperature Range
(See Power Derating Curve)
Case Temperature
Conditions
Min.
-40
Max.
+92
Unit
℃
---
+105
+125
℃
℃
Storage Temperature Range
Cooling Test
-50
Compliance to IEC/EN 60068-2-1
Compliance to IEC/EN 60068-2-2
Compliance to IEC/EN 60068-2-30
Compliance to IEC/EN 61373
---
Dry Heat
Damp Heat
Shock & Vibration Test
Humidity (non condensing)
95
% rel. H
Lead Temperature (1.5mm from case for 10Sec.)
---
260
℃
E-mail:sales@minmax.com.tw Tel:886-6-2923150
2018/08/31 REV:4
Page 2 of 5
®
MIZI03 SERIES
DC-DC CONVERTER 3W, Railway Certified
EMC Specifications
Parameter
General
EMI
Standards & Level
Performance
Compliance with EN 50121-3-2 Railway Applications
EN 55032, EN 55011, FCC part 15
Conduction & Radiation
EN 55024
Class A
ESD
EN 61000-4-2 Air ± 8kV, Contact ± 6kV
EN 61000-4-3 10V/m
A
A
A
A
A
A
Radiated immunity
Fast transient(4)
Surge(4)
EN 61000-4-4 ±2kV
EMS
EN 61000-4-5 ±2kV
Conducted immunity
PFMF
EN 61000-4-6 10Vrms
EN 61000-4-8 3A/M
Power Derating Curve
Notes
1
2
3
4
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%.
We recommend to protect the converter by a slow blow fuse in the input supply line.
To meet EN 61000-4-4 & EN 61000-4-5 an external capacitor across the input pins is required.
Suggested capacitor: 24XXX: CHEMI-CON KY Series 470μF/50V.
48XXX: CHEMI-CON KY Series 330μF/100V.
110XXX: CHEMI-CON KXG Series 220μF/250V.
5
6
Other input and output voltage may be available, please contact factory.
Specifications are subject to change without notice.
E-mail:sales@minmax.com.tw Tel:886-6-2923150
2018/08/31 REV:4 Page 3 of 5
®
MIZI03 SERIES
DC-DC CONVERTER 3W, Railway Certified
Package Specifications
Mechanical Dimensions
Pin Connections
Pin
1
Single Output
+Vin
Dual Output
+Vin
11
12
13
15
23
24
No Pin
-Vout
Common
No Pin
-Vout
+Vout
No Pin
-Vin
+Vout
0.60 [0.024]
-Vin
-Vin
-Vin
1
11 12
Bottom View
24 23
15
13
►All dimensions in mm (inches)
►Tolerance: X.X±0.5 (X.XX±0.02)
20.32 [0.80]
31.8 [1.25]
5.08
[0.20]
2.0
[0.08]
2.54
[0.10]
X.XX±0.25 ( X.XXX±0.01)
►Pin diameter 0.6 ±0.05 (0.024±0.002)
Physical Characteristics
Case Size
Case Material
Pin Material
Weight
:
:
:
:
31.8x20.3x12.0mm (1.25x0.8x0.47 inches)
Non-Conductive Black Plastic (flammability to UL 94V-0 rated)
Tinned Copper
15.4g
E-mail:sales@minmax.com.tw Tel:886-6-2923150
2018/08/31 REV:4 Page 4 of 5
®
MIZI03 SERIES
DC-DC CONVERTER 3W, Railway Certified
Test Setup
Peak-to-Peak Output Noise Measurement Test
Refer to the output specifications or add 4.7μF capacitor if the output specifications undefine Cout. Scope measurement should be made by using a BNC socket,
measurement bandwidth is 0-20 MHz. Position the load between 50 mm and 75 mm from the DC-DC Converter.
Copper Strip
Cout
+Vin
+Out
Copper Strip
+Vin
+Out
Com.
-Out
Scope
Scope
Single Output
DC / DC
Converter
Dual Output
DC / DC
Converter
Resistive
Load
Resistive
Load
Cout
Scope
Copper Strip
Cout
-Vin
-Out
Copper Strip
-Vin
Copper Strip
Technical Notes
Overload Protection
To provide hiccup mode protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure overload for an
unlimited duration.
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module.
In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup.
Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR < 1.0
Ω at 100 kHz) capacitor of 4.7μF for the 24V input devices, a 2.2μF for the 48V devices and a 1μF for the 110V devices.
+
+Vin
+Out
+
DC / DC
Converter
DC Power
Source
Load
Cin
-
-Vin
-Out
Output Ripple Reduction
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is
recommended to use 4.7μF capacitors at the output.
+
+Vin
+Out
+
+Vin
-Vin
+Out
Load
Load
Single Output
DC / DC
Converter
Dual Output
Cout
Cout
DC Power
Source
DC Power
Source
DC / DC Com.
Converter
Cout
Load
-
-Vin
-Out
-
-Out
Maximum Capacitive Load
The MIZI03 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up,
affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet.
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the
maximum temperature rating of the components inside the power module, the case temperature must be kept below 105℃. The derating curves are determined from
measurements obtained in a test setup.
Position of air velocity
probe and thermocouple
Air Flow
50mm / 2in
15mm / 0.6in
DUT
Minmax Technology Co., Ltd.
18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan
Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: sales@minmax.com.tw
2018/08/31 REV:4
Page 5 of 5
©2020 ICPDF网 联系我们和版权申明