MEW1000 SERIES  
DC/DC CONVERTER 2W, SIP-Package  
FEATURES  
High Power Density in SIP-9 Package  
Small Footprint: 26 x 9.2 mm (1.02”x 0.36”)  
Ultra-wide 4:1 Input Range  
Fully Regulated Output  
Operating Temp. Range -40°C to +85°C  
Overload Protection  
I/O-Isolation Voltage 1500 VDC  
Remote On/Off Control  
3 Years Product Warranty  
PRODUCT OVERVIEW  
The MINMAX MEW1000 series is a range of isolated 2W DC/DC converter modules featuring fully regulated output and ultra-wide 4:1 input voltage ranges.  
2
The product comes in a SIP-9 package with a very small footprint occupying only 2.4 cm (0.36 square in.) on the PCB.  
An excellent efficiency allows an operating temperature range of -40°C to +85°C. Further features include remote On/Off control and over load protection.  
The very compact dimensions of these DC/DC converters make them an ideal solution for many space critical applications in battery-powered equipment  
and instrumentation.  
Model Selection Guide  
Model  
Input  
Voltage  
(Range)  
VDC  
Output  
Output Current  
Input Current  
Reflected  
Ripple  
Max. capacitive  
Load  
Efficiency  
Number  
Voltage  
(typ.)  
Current  
mA(typ.)  
Max.  
mA  
500  
400  
167  
134  
200  
83  
Min.  
mA  
125  
100  
42  
@Max. Load  
@No Load  
mA(typ.)  
@Max. Load  
VDC  
3.3  
5
mA(typ.)  
97  
µF  
%
71  
76  
79  
80  
73  
77  
79  
70  
72  
78  
78  
70  
76  
76  
MEW1021  
MEW1022  
MEW1023  
MEW1024  
MEW1025  
MEW1026  
MEW1027  
MEW1031  
MEW1032  
MEW1033  
MEW1034  
MEW1035  
MEW1036  
MEW1037  
2200  
1000  
170  
110  
106  
105  
114  
108  
106  
49  
12  
15  
5
24  
33  
20  
300  
110  
(9 ~ 36)  
50  
470#  
100#  
47#  
12  
15  
3.3  
5
21  
67  
17  
500  
400  
167  
134  
200  
83  
125  
100  
42  
2200  
1000  
170  
58  
12  
15  
5
54  
48  
(18 ~ 75)  
33  
54  
15  
600  
110  
50  
60  
470#  
100#  
47#  
12  
15  
21  
55  
67  
17  
55  
# For each output  
Input Specifications  
Parameter  
Model  
Min.  
-0.7  
Typ.  
---  
Max.  
50  
Unit  
24V Input Models  
Input Surge Voltage (1 sec. max.)  
100  
48V Input Models  
24V Input Models  
48V Input Models  
24V Input Models  
48V Input Models  
-0.7  
4.5  
8.5  
---  
---  
6
8.5  
17  
VDC  
Start-Up Threshold Voltage  
Under Voltage Shutdown  
12  
---  
---  
---  
---  
8
---  
16  
---  
0.5  
1500  
A
Reverse Polarity Input Current  
Short Circuit Input Power  
Internal Filter Type  
---  
mW  
All Models  
Capacitor type  
---  
---  
2500  
mW  
Internal Power Dissipation  
E-mail:sales@minmax.com.tw Tel:886-6-2923150  
2013/02/04 REV:7 Page 1 of 4  
®
MEW1000 SERIES  
DC/DC CONVERTER 2W, SIP-Package  
Output Specifications  
Parameter  
Conditions  
Min.  
---  
Typ.  
---  
Max.  
2.0  
2.0  
0.5  
0.75  
50  
Unit  
%Vnom.  
%
Output Voltage Setting Accuracy  
Output Voltage Balance  
Line Regulation  
At 50% Load and Nominal Vin  
Dual Output, Balanced Loads  
Vin=Min. to Max.  
---  
1.0  
0.3  
0.5  
30  
---  
%
Load Regulation  
Io=25% to 100%  
---  
%
Ripple & Noise  
max. 20MHz Bandwidth  
---  
mV P-P  
µsec  
%
Transient Recovery Time  
Transient Response Deviation  
Temperature Coefficient  
Output Short Circuit  
---  
100  
3
300  
5
25% Load Step Change  
---  
---  
0.01  
0.02  
%/  
Continuous  
General Specifications  
Parameter  
Conditions  
60 Seconds  
500 VDC  
Min.  
1500  
1000  
---  
Typ.  
---  
Max.  
---  
Unit  
VDC  
MΩ  
I/O Isolation Voltage (rated)  
I/O Isolation Resistance  
I/O Isolation Capacitance  
Switching Frequency  
MTBF (Calculated)  
---  
---  
100KHz, 1V  
250  
300  
---  
500  
---  
pF  
---  
KHz  
Hours  
MIL-HDBK-217F@25, Ground Benign  
1,000,000  
---  
Input Fuse  
24V Input Models  
48V Input Models  
350mA Slow-Blow Type  
135mA Slow-Blow Type  
Remote On/Off Control  
Parameter  
Conditions  
Min.  
Typ.  
Max.  
Unit  
Converter On  
Converter Off  
Under 0.6 VDC or Open Circuit, drops down to 0VDC by 2mV/℃  
2.9 to 15 VDC  
Standby Input Current  
Control Input Current ( on )  
Control Input Current ( off )  
Control Common  
---  
1
3
-1  
1
mA  
mA  
mA  
Vin = 0V  
---  
---  
---  
Vin = 5.0V  
---  
Referenced to Negative Input  
Environmental Specifications  
Parameter  
Conditions  
Natural Convection  
Min.  
-40  
---  
Max.  
+85  
+90  
+105  
95  
Unit  
Operating Ambient Temperature Range (See Power Derating Curve)  
Case Temperature  
Storage Temperature Range  
Humidity (non condensing)  
-55  
---  
% rel. H  
Cooling  
Free-Air convection  
---  
Lead Temperature (1.5mm from case for 10Sec.)  
260  
Power Derating Curve  
E-mail:sales@minmax.com.tw Tel:886-6-2923150  
2013/02/04 REV:7  
Page 2 of 4  
®
MEW1000 SERIES  
DC/DC CONVERTER 2W, SIP-Package  
Notes  
1
2
3
4
Specifications typical at Ta=+25, resistive load, nominal input voltage and rated output current unless otherwise noted.  
Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%.  
Ripple & Noise measurement bandwidth is 0-20 MHz.  
These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these  
modules; however, they may not meet all specifications listed.  
5
6
7
All DC/DC converters should be externally fused at the front end for protection.  
Other input and output voltage may be available, please contact factory.  
Specifications are subject to change without notice.  
Package Specifications  
Mechanical Dimensions  
Pin Connections  
25.95 [1.02]  
Pin  
1
Single Output  
Dual Output  
-Vin  
-Vin  
+Vin  
2
+Vin  
3
Remote On/Off  
+Vout  
Remote On/Off  
+Vout  
6
7
NC  
Common  
NC  
8
NC  
0.5  
9
-Vout  
-Vout  
[0.02]  
2X2.54  
3X2.54  
7.62  
[0.30]  
2.0  
[0.08]  
[2X0.10]  
[3X0.10]  
NC: No Connection  
24.95 [0.98]  
Bottom View  
All dimensions in mm (inches)  
Tolerance: X.X 0.5 (X.XX 0.02)  
1
2
3
6
7
8
9
X.XX 0.25 ( X.XXX 0.01)  
Pins 0.1( 0.004)  
0.50  
[0.02]  
Physical Characteristics  
Case Size  
Case Material  
Pin Material  
Weight  
:
:
:
:
25.95x9.25x12.45 mm (1.02x0.36x0.49 inches)  
Non-Conductive Black Plastic (flammability to UL 94V-0 rated)  
Alloy 42  
6.5g  
E-mail:sales@minmax.com.tw Tel:886-6-2923150  
2013/02/04 REV:7 Page 3 of 4  
®
MEW1000 SERIES  
DC/DC CONVERTER 2W, SIP-Package  
Test Setup  
Input Reflected-Ripple Current Test Setup  
Input reflected-ripple current is measured with a inductor Lin (4.7µH) and Cin (220µF, ESR < 1.0Ω at 100 KHz) to simulate source impedance. Capacitor Cin, offsets  
possible battery impedance.  
Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz.  
To Oscilloscope  
+Vin  
+Out  
+
+
Lin  
DC / DC  
Converter  
Current  
Probe  
Load  
Battery  
Cin  
-Vin  
-Out  
Peak-to-Peak Output Noise Measurement Test  
Use a Cout 0.47µF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load  
between 50 mm and 75 mm from the DC/DC Converter.  
Copper Strip  
Cout  
+Vin  
+Out  
Copper Strip  
Cout  
+Vin  
+Out  
Com.  
-Out  
Scope  
Scope  
Single Output  
DC / DC  
Converter  
Dual Output  
DC / DC  
Converter  
Resistive  
Load  
Resistive  
Load  
Scope  
Copper Strip  
Cout  
-Vin  
-Out  
Copper Strip  
-Vin  
Copper Strip  
Technical Notes  
Remote On/Off  
Negative logic remote on/off turns the module off during a logic high voltage on the remote on/off pin, and on during a logic low. To turn the power module on and off,  
the user must supply a switch to control the voltage between the on/off terminal and the -Vin terminal. The switch can be an open collector or equivalent.  
A logic high is 2.9V to 15V. A logic low is under 0.6 VDC or open circuit, drops down to 0VDC by 2mV/. The maximum sink current at on/off terminal during a  
logic low is 1 mA. The maximum allowable leakage current of the switch at on/off terminal =(under 0.6VDC or open circuit) is 1mA.  
Maximum Capacitive Load  
The MEW1000 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up,  
affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet.  
Overcurrent Protection  
To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure current limiting for an unlimited  
duration. At the point of current-limit inception, the unit shifts from voltage control to current control. The unit operates normally once the output current is brought back  
into its specified range.  
Input Source Impedance  
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module.  
In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor on the input to insure startup.  
By using a good quality low Equivalent Series Resistance (ESR < 1.0Ω at 100 kHz) capacitor of a 1.5µF for the 24V and 48V devices, capacitor mounted close to the  
power module helps ensure stability of the unit.  
+
+Vin  
+Out  
+
DC / DC  
Converter  
DC Power  
Source  
Load  
Cin  
-
-Vin  
-Out  
Output Ripple Reduction  
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is  
recommended to use 3.3µF capacitors at the output.  
+
+Vin  
-Vin  
+Out  
+
+Vin  
+Out  
Single Output  
DC / DC  
Converter  
Load  
Load  
Dual Output  
DC Power  
Source  
Cout  
Cout  
DC Power  
Source  
DC / DC Com.  
Converter  
Cout  
Load  
-
-Out  
-
-Vin  
-Out  
Thermal Considerations  
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the  
maximum temperature rating of the components inside the power module, the case temperature must be kept below 90. The derating curves are determined  
from measurements obtained in a test setup.  
Position of air velocity  
probe and thermocouple  
Air Flow  
50mm / 2in  
15mm / 0.6in  
DUT  
Minmax Technology Co., Ltd.  
18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan  
Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: sales@minmax.com.tw  
2013/02/04 REV:7  
Page 4 of 4  

相关型号:

MEW1021

2W, Wide Input Range SIP, Single & Dual Output DC/DC Converters
MINMAX

MEW1022

2W, Wide Input Range SIP, Single & Dual Output DC/DC Converters
MINMAX

MEW1023

2W, Wide Input Range SIP, Single & Dual Output DC/DC Converters
MINMAX

MEW1024

2W, Wide Input Range SIP, Single & Dual Output DC/DC Converters
MINMAX

MEW1025

2W, Wide Input Range SIP, Single & Dual Output DC/DC Converters
MINMAX

MEW1026

2W, Wide Input Range SIP, Single & Dual Output DC/DC Converters
MINMAX

MEW1027

2W, Wide Input Range SIP, Single & Dual Output DC/DC Converters
MINMAX

MEW1031

2W, Wide Input Range SIP, Single & Dual Output DC/DC Converters
MINMAX

MEW1032

2W, Wide Input Range SIP, Single & Dual Output DC/DC Converters
MINMAX

MEW1033

2W, Wide Input Range SIP, Single & Dual Output DC/DC Converters
MINMAX

MEW1034

2W, Wide Input Range SIP, Single & Dual Output DC/DC Converters
MINMAX

MEW1035

2W, Wide Input Range SIP, Single & Dual Output DC/DC Converters
MINMAX