MEW1031 [MINMAX]

2W, Wide Input Range SIP, Single & Dual Output DC/DC Converters; 2W ,宽输入范围的SIP ,单和双输出DC / DC转换器
MEW1031
型号: MEW1031
厂家: MINMAX TECHNOLOGY CO., LTD.    MINMAX TECHNOLOGY CO., LTD.
描述:

2W, Wide Input Range SIP, Single & Dual Output DC/DC Converters
2W ,宽输入范围的SIP ,单和双输出DC / DC转换器

转换器
文件: 总8页 (文件大小:187K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MEW1000 Series  
2W, Wide Input Range SIP, Single & Dual Output DC/DC Converters  
Key Features  
y
y
y
y
y
y
y
y
y
y
Efficiency up to 80%  
1500VDC Isolation  
MTBF > 1,000,000 Hours  
4:1 Wide Input Range  
Low Cost  
Remote On/Off Control  
Low Ripple and Noise  
Temperature Performance -40] to +75]  
UL 94V-0 Package Material  
Internal SMD Construction  
1500  
VDC  
4:1  
$
Remote on/off  
Wide Range  
Low Cost  
I/O Isolation  
Low Noise  
Low Profile  
Minmax's MEW1000-Series power modules are low-profile dc-dc converters that operate over input voltage ranges of 9-36VDC and  
18-75VDC which provide precisely regulated output voltages of 3.3V, 5V, 12V, 15V, {5V, {12V and {15VDC.  
The MEW1000 series is an excellent selection for data communication equipments, mobile battery driven equipments, distributed power  
systems, telecommunication equipments, mixed analog/digital subsystems, process/machine control equipments, computer peripheral  
systems and industrial robot systems.  
The modules have a maximum power rating of 2W and a typical full-load efficiency of 80%, continuous short circuit, 30mV output ripple,  
built-in filtering for both input and output minimize the need for external filtering.  
Absolute Maximum Ratings  
Environmental Specifications  
Parameter  
Min. Max. Unit  
-0.7 50 VDC  
-0.7 100 VDC  
--- 260  
--- 2,500 mW  
Parameter  
Operating Temperature  
Operating Temperature  
Storage Temperature  
Humidity  
Conditions Min. Max. Unit  
24VDC Input Models  
48VDC Input Models  
Ambient  
Case  
-40  
-40  
+75  
+90  
]
]
]
%
Input Surge Voltage  
( 1000 mS )  
Lead Temperature (1.5mm from case for 10 Sec.)  
Internal Power Dissipation  
]
-55 +105  
--- 95  
Free-Air Convection  
Cooling  
Exceeding the absolute maximum ratings of the unit could cause damage.  
These are not continuous operating ratings.  
REV:3 2008/10/02  
MINMAX  
1
MEW1000 Series  
Model Selection Guide  
Model  
Number  
Input  
Voltage  
Output  
Voltage  
Output Current  
Input Current  
Reflected  
Ripple  
Current  
Efficiency  
Max.  
mA  
500  
400  
Min.  
mA  
125  
100  
42  
@Max. Load  
mA (Typ.)  
97  
@No Load  
mA (Typ.)  
@Max. Load  
% (Typ.)  
71  
VDC  
VDC  
3.3  
5
mA (Typ.)  
MEW1021  
MEW1022  
MEW1023  
MEW1024  
MEW1025  
MEW1026  
MEW1027  
MEW1031  
MEW1032  
MEW1033  
MEW1034  
MEW1035  
MEW1036  
MEW1037  
110  
106  
105  
114  
108  
106  
49  
76  
12  
167  
79  
24  
( 9 ~ 36 )  
15  
134  
33  
20  
15  
300  
80  
{5  
{12  
{15  
3.3  
5
{200  
{83  
{67  
500  
{50  
{21  
{17  
125  
100  
42  
73  
77  
79  
70  
400  
58  
72  
12  
167  
54  
78  
48  
15  
134  
33  
54  
600  
78  
( 18 ~ 75 )  
{5  
{12  
{15  
{200  
{83  
{67  
{50  
{21  
{17  
60  
70  
55  
76  
55  
76  
Capacitive Load  
Models by Vout  
3.3V  
5V  
12V  
170  
15V  
{5V #  
470  
{12V #  
{15V #  
47  
Unit  
Maximum Capacitive Load  
2200  
1000  
110  
100  
uF  
# For each output  
Input Fuse Selection Guide  
24V Input Models  
350mA Slow - Blow Type  
48V Input Models  
135mA Slow - Blow Type  
Input Specifications  
Parameter  
Model  
Min.  
4.5  
Typ.  
6
Max.  
Unit  
Start Voltage  
24V Input Models  
48V Input Models  
24V Input Models  
48V Input Models  
8.5  
17  
8
8.5  
12  
VDC  
Under Voltage Shutdown  
---  
---  
---  
---  
---  
---  
---  
---  
16  
0.5  
Reverse Polarity Input Current  
Short Circuit Input Power  
Input Filter  
A
All Models  
1500  
mW  
Capacitor type  
REV:3 2008/10/02  
MINMAX  
2
MEW1000 Series  
Output Specifications  
Parameter  
Conditions  
Min.  
---  
Typ.  
{1.0  
{1.0  
{0.3  
{0.5  
30  
Max.  
{2.0  
{2.0  
{0.5  
{0.75  
50  
Unit  
%
Output Voltage Accuracy  
Output Voltage Balance  
Line Regulation  
Dual Output, Balanced Loads  
Vin=Min. to Max.  
---  
%
---  
%
Load Regulation  
Io=25% to 100%  
---  
%
Ripple & Noise (20MHz)  
Ripple & Noise (20MHz)  
Ripple & Noise (20MHz)  
Over Power Protection  
Transient Recovery Time  
Transient Response Deviation  
Temperature Coefficient  
Output Short Circuit  
---  
mV P-P  
mV P-P  
mV rms  
%
Over Line, Load & Temp.  
25% Load Step Change  
---  
---  
---  
---  
100  
75  
---  
15  
120  
---  
300  
---  
uS  
---  
{3  
{5  
%
---  
{0.01  
{0.02  
%/]  
Continuous  
General Specifications  
Parameter  
Conditions  
60 Seconds  
Min.  
1500  
1650  
1000  
---  
---  
1000  
Typ.  
---  
---  
---  
250  
Max.  
---  
---  
---  
500  
Unit  
VDC  
VDC  
M[  
Isolation Voltage Rated  
Isolation Voltage Test  
Isolation Resistance  
Isolation Capacitance  
Switching Frequency  
MTBF  
Flash Tested for 1 Second  
500VDC  
100KHz,1V  
pF  
300  
---  
---  
KHz  
MIL-HDBK-217F @ 25], Ground Benign  
---  
K Hours  
Remote On/Off Control  
Parameter  
Conditions  
Min.  
Typ.  
Max.  
Unit  
Supply On  
Under 0.6 VDC or Open Circuit, drops down to 0VDC by 2mV/]  
Supply Off  
2.9  
---  
1
15  
3
VDC  
mA  
Device Standby Input Current  
Control Input Current ( on )  
Control Input Current ( off )  
Control Common  
---  
---  
---  
Vin = 0V  
---  
---  
-1  
1
mA  
Vin = 5.0V  
mA  
Referenced to Negative Input  
Notes:  
1. Specifications typical at Ta=+25], resistive load, nominal input voltage, rated output current unless otherwise noted.  
2. Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%.  
3. Ripple & Noise measurement bandwidth is 0-20 MHz.  
4. These power converters require a minimum output loading to maintain specified regulation.  
5. Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed.  
6. All DC/DC converters should be externally fused on the front end for protection.  
7. Other input and output voltage may be available, please contact factory.  
8. Specifications subject to change without notice.  
REV:3 2008/10/02  
MINMAX  
3
MEW1000 Series  
Block Diagram  
Single Output  
Dual Output  
+Vo  
-Vo  
+Vo  
Com.  
-Vo  
+Vin  
+Vin  
-Vin  
PFM  
Isolation  
Ref.Amp  
-Vin  
On/Off  
PFM  
Isolation  
Ref.Amp  
On/Off  
Input Voltage Transient Rating  
150  
140  
130  
120  
110  
100  
90  
48VDC Input Models  
24VDC Input Models  
80  
70  
60  
50  
40  
30  
20  
10  
0
10uS  
100uS  
1mS  
10mS  
100mS  
REV:3 2008/10/02  
MINMAX  
4
MEW1000 Series  
100  
90  
80  
70  
60  
50  
40  
100  
90  
80  
70  
60  
50  
40  
Nom  
Low  
High  
Nom  
Low  
High  
Input Voltage (V)  
Input Voltage (V)  
Efficiency vs Input Voltage ( Single Output )  
Efficiency vs Input Voltage ( Dual Output )  
90  
80  
70  
60  
50  
40  
30  
20  
90  
80  
70  
60  
50  
40  
30  
20  
10  
60  
80  
100  
20  
40  
10  
100  
20  
40  
60  
80  
Load Current(%)  
Load Current(%)  
Efficiency vs Output Load ( Single Output )  
Efficiency vs Output Load ( Dual Output )  
100  
400LFM  
200LFM  
100LFM  
80  
Natural  
convection  
60  
40  
20  
0
-40  
50  
60  
70  
80  
90  
100  
110  
Ambient Temperature  
]
Derating Curve  
REV:3 2008/10/02  
MINMAX  
5
MEW1000 Series  
Maximum Capacitive Load  
Test Configurations  
The MEW1000 series has limitation of maximum  
connected capacitance on the output.  
Input Reflected-Ripple Current Test Setup  
The power module may operate in current limiting mode  
during start-up, affecting the ramp-up and the startup time.  
The maximum capacitance can be found in the data sheet.  
Input reflected-ripple current is measured with a inductor  
Lin (4.7uH) and Cin (220uF, ESR < 1.0[ at 100 kHz) to  
simulated source impedance.  
Capacitor Cin, offsets possible battery impedance.  
Current ripple is measured at the input terminals of the  
module, measurement bandwidth is 0-500KHz.  
Overcurrent Protection  
To provide protection in a fault (output overload) condition,  
the unit is equipped with internal current limiting circuitry and  
can endure current limiting for an unlimited duration. At the  
point of current-limit inception, the unit shifts from voltage  
control to current control. The unit operates normally once the  
output current is brought back into its specified range.  
To Oscilloscope  
+Vin  
+Out  
+
+
Lin  
DC / DC  
Converter  
Current  
Probe  
Load  
Battery  
Cin  
-Vin  
-Out  
Input Source Impedance  
The power module should be connected to a low  
ac-impedance input source. Highly inductive source  
impedances can affect the stability of the power module.  
In applications where power is supplied over long lines and  
output loading is high, it may be necessary to use a capacitor  
on the input to insure startup.  
By using a good quality low Equivalent Series Resistance  
(ESR < 1.0[ at 100 kHz) capacitor of a 1.5uF for the 24V and  
48V devices, capacitor mounted close to the power module  
helps ensure stability of the unit.  
Peak-to-Peak Output Noise Measurement Test  
Use a Cout 0.47uF ceramic capacitor.  
Scope measurement should be made by using a BNC  
socket, measurement bandwidth is 0-20 MHz. Position the  
load between 50 mm and 75 mm from the DC/DC Converter.  
+Vin  
+Out  
Copper Strip  
Cout  
Single Output  
DC / DC  
Resistive  
Load  
Scope  
+
+Vin  
DC / DC  
+Out  
Converter  
+
DC Power  
Source  
-Vin  
-Out  
Load  
Converter  
Cin  
-
-Vin  
-Out  
Copper Strip  
Cout  
+Vin  
+Out  
Com.  
-Out  
Scope  
Scope  
Dual Output  
DC / DC  
Resistive  
Load  
Output Ripple Reduction  
Converter  
Cout  
A good quality low ESR capacitor placed as close as  
practicable across the load will give the best ripple and noise  
performance.  
-Vin  
To reduce output ripple, it is recommended that 3.3uF  
capacitors are used on output.  
Design & Feature Considerations  
Remote On/Off  
+
+Vin  
-Vin  
+Vin  
-Vin  
+Out  
-Out  
Negative logic remote on/off turns the module off during a  
logic high voltage on the remote on/off pin, and on during a  
logic low.  
To turn the power module on and off, the user must supply  
a switch to control the voltage between the on/off terminal and  
the -Vin terminal.  
The switch can be an open collector or equivalent.  
A logic high is 2.9V to 15V.  
A logic low is under 0.6 VDC or open circuit, drops down to  
0VDC by 2mV/]  
The maximum sink current at on/off terminal during a logic  
low is 1 mA.  
The maximum allowable leakage current of the switch at  
on/off terminal =(under 0.6VDC or open circuit) is 1mA.  
Single Output  
DC / DC  
DC Power  
Source  
Converter  
Cout  
Load  
-
+
+Out  
Com.  
-Out  
Dual Output  
DC / DC  
Cout  
Load  
DC Power  
Source  
Converter  
-
REV:3 2008/10/02  
MINMAX  
6
MEW1000 Series  
Thermal Considerations  
Many conditions affect the thermal performance of the  
power module, such as orientation, airflow over the module,  
and board spacing. To avoid exceeding the maximum  
temperature rating of the components inside the power  
module, the case temperature must be kept below 90°C.  
The derating curves were determined from measurements  
obtained in an experimental apparatus.  
Position of air velocity  
Air Flow  
50mm / 2in  
probe and thermocouple  
15mm / 0.6in  
DUT  
REV:3 2008/10/02  
MINMAX  
5
MEW1000 Series  
Physical Characteristics  
Mechanical Dimensions  
25.95*9.25*12.45 mm  
1.02*0.36*0.49 inches  
:
Case Size  
Case Material  
Weight  
:
:
:
Non-Conductive Black Plastic  
2.54  
6.5g  
2.03[0.08]  
7.62[0.300]  
[0.100]  
9.25[0.36]  
2.54[0.100]X8=20.32[0.80]  
25.95[1.02]  
Flammability  
UL94V-0  
1
2
3
6
7
8
9
0.5[0.02]  
Tolerance  
Pin  
Millimeters  
X.X{0.25  
X.XX{0.13  
{0.05  
Inches  
X.XX{0.01  
X.XXX{0.005  
{0.002  
Pin Connections  
Pin  
1
Single Output  
-Vin  
Dual Output  
-Vin  
2
+Vin  
+Vin  
3
Remote On/Off  
+Vout  
Remote On/Off  
+Vout  
6
7
NC  
Common  
NC  
8
NC  
9
-Vout  
-Vout  
NC: No Connection  
REV:3 2008/10/02  
MINMAX  
8

相关型号:

MEW1032

2W, Wide Input Range SIP, Single & Dual Output DC/DC Converters
MINMAX

MEW1033

2W, Wide Input Range SIP, Single & Dual Output DC/DC Converters
MINMAX

MEW1034

2W, Wide Input Range SIP, Single & Dual Output DC/DC Converters
MINMAX

MEW1035

2W, Wide Input Range SIP, Single & Dual Output DC/DC Converters
MINMAX

MEW1036

2W, Wide Input Range SIP, Single & Dual Output DC/DC Converters
MINMAX

MEW1037

2W, Wide Input Range SIP, Single & Dual Output DC/DC Converters
MINMAX

MEWT-110-B

Plug-in Signal Conditioners M-UNIT
MSYSTEM

MEWT-110-B/Q

Plug-in Signal Conditioners M-UNIT
MSYSTEM

MEWT-110-C

Plug-in Signal Conditioners M-UNIT
MSYSTEM

MEWT-110-C/Q

Plug-in Signal Conditioners M-UNIT
MSYSTEM

MEWT-110-D

Plug-in Signal Conditioners M-UNIT
MSYSTEM

MEWT-110-D/Q

Plug-in Signal Conditioners M-UNIT
MSYSTEM