SY10E337JZ [MICREL]

3-BIT SCANNABLE REGISTERED BUS TRANSCEIVER; 3位可扫描户籍总线收发器
SY10E337JZ
型号: SY10E337JZ
厂家: MICREL SEMICONDUCTOR    MICREL SEMICONDUCTOR
描述:

3-BIT SCANNABLE REGISTERED BUS TRANSCEIVER
3位可扫描户籍总线收发器

总线收发器
文件: 总5页 (文件大小:67K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
7  
3-BIT SCANNABLE  
REGISTERED BUS  
TRANSCEIVER  
7  
SY10E337  
SY100E337  
FEATURES  
DESCRIPTION  
1500ps max. clock to bus (data transmit)  
1000ps max. clock to Q (data receive)  
Extended 100E VEE range of –4.2V to –5.5V  
25cutoff bus outputs  
The SY10/100E337 are 3-bit registered bus transceivers  
with scan designed for use in new, high- performance ECL  
systems. The bus outputs (BUS0–BUS2) are designed to  
drive a 25bus; the receive outputs (Q0–Q2) are designed  
for 50. The bus outputs feature a normal logic HIGH level  
(VOH) and a cutoff LOW level of –2.0V and the output  
emitter-follower is “off”, presenting a high impedance to the  
bus. The bus outputs also feature edge slow-down  
capacitors.  
Both drive and receive sides feature the same logic,  
including a loopback path to hold data. The LOAD/HOLD  
functioniscontrolledbyTransmitEnable(TEN)andReceive  
Enable (REN) on the transmit and receive sides,  
respectively, with a HIGH selecting LOAD. The  
implementation of the E337 Receive Enable differs from  
that of the E336.  
50receiver outputs  
Scannable implementation of E336  
Synchronous and asynchronous bus enables  
Non-inverting data path  
Bus outputs feature internal edge slow-down  
capacitors  
Additional package ground pins  
Fully compatible with industry standard 10KH,  
100K ECL levels  
Internal 75Kinput pulldown resistors  
Fully compatible with Motorola MC10E/100E337  
Available in 28-pin PLCC package  
A synchronous bus enable (SBUSEN) is provided for  
normal, non-scan operation. The asynchronous bus disable  
(ABUSDIS) disables the bus for scan mode.  
The SYNCEN input allows either synchronous or  
asynchronous re-enabling after disabling with ABUSDIS.  
An alternative use is asynchronous-only operation with  
ABUSDIS, in which case SYNCEN is tied LOW. SYNCEN  
is implemented as an overriding SET control to the enable  
flip-flop.  
Scan mode is selected by a logic HIGH at the SCAN  
input. Scan input data is shifted in through S-IN, and output  
data appears at the Q2 output.  
All registers are clocked on the rising edge of CLK.  
Additional lead-frame grounding is provided through the  
ground pins (GND) which should be connected to 0V. The  
GND pins are not electrically connected to the chip.  
PIN NAMES  
Pin  
Function  
Data Inputs A  
A0–A2  
B0–B2  
Data Inputs B  
S-IN  
Serial (Scan) Data Input  
LOAD/HOLD Controls  
Scan Control  
TEN, REN  
SCAN  
ABUSDIS  
SBUSEN  
SYNCEN  
CLK  
Asynchronous Bus Disable  
Synchronous Bus Enable  
Synchronous Enable Control  
Clock  
BUS0–BUS2  
Q0–Q2  
25Cutoff BUS Outputs  
Receive Data Outputs (Q2 serves as  
SCAN_OUT in scan mode)  
VCCO  
VCC to Output  
Rev.: F  
Amendment: /0  
M9999-032206  
hbwhelp@micrel.com or (408) 955-1690  
1
Issue Date: March 2006  
SY10E337  
SY100E337  
Micrel, Inc.  
PACKAGE/ORDERING INFORMATION  
Ordering Information(1)  
Package Operating  
Package  
Marking  
Lead  
Finish  
Part Number  
Type  
J28-1  
J28-1  
J28-1  
Range  
SY10E337JC  
Commercial  
Commercial  
Commercial  
SY10E337JC  
SY10E337JC  
SY100E337JC  
Sn-Pb  
Sn-Pb  
Sn-Pb  
25 24 23 22 21 20 19  
SY10E337JCTR(2)  
SCAN  
S-IN  
26  
27  
28  
1
18  
17  
16  
15  
14  
13  
12  
GND  
BUS  
0
SY100E337JC  
TEN  
V
CC  
TOP VIEW  
PLCC  
SY100E337JCTR(2)  
SY10E337JZ(3)  
J28-1  
J28-1  
Commercial  
Commercial  
SY100E337JC  
Sn-Pb  
V
EE  
Q
1
J28-1  
REN  
CLK  
2
V
CCO  
SY10E337JZ with  
Matte-Sn  
3
BUS  
1
Pb-Free bar-line indicator  
A
1
4
GND  
SY10E337JZTR(2, 3)  
SY100E337JZ(3)  
J28-1  
J28-1  
Commercial  
Commercial  
SY10E337JZ with  
Pb-Free bar-line indicator  
Matte-Sn  
Matte-Sn  
5
6
7
8
9
10 11  
SY100E337JZ with  
Pb-Free bar-line indicator  
SY100E337JZTR(2, 3)  
J28-1  
Commercial  
SY100E337JZ with  
Matte-Sn  
28-Pin PLCC (J28-1)  
Pb-Free bar-line indicator  
Notes:  
1. Contact factory for die availability. Dice are guaranteed at T = 25°C, DC Electricals only.  
A
2. Tape and Reel.  
3. Pb-Free package is recommended for new designs.  
M9999-032206  
hbwhelp@micrel.com or (408) 955-1690  
2
SY10E337  
SY100E337  
Micrel, Inc.  
BLOCK DIAGRAM  
BUS  
2
Q
2
D
D
D
D
D
D
Q
Q
Q
Q
Q
Q
SCAN-OUT  
A2  
B2  
BUS  
1
Q1  
A1  
B1  
BUS  
0
Q0  
A0  
B0  
S-IN  
TEN  
REN  
SCAN  
ABUSDIS  
SBUSEN  
D
Q
SET  
SYNCEN  
CLK  
M9999-032206  
hbwhelp@micrel.com or (408) 955-1690  
3
SY10E337  
SY100E337  
Micrel, Inc.  
DC ELECTRICAL CHARACTERISTICS  
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND  
TA = 0°C  
TA = +25°C  
TA = +85°C  
Symbol  
Parameter  
Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit  
Condition  
VCUT  
IIH  
Cut-off Output Voltage  
2.10  
2.03 2.10  
2.03 2.10  
2.03  
V
1
Input HIGH Current  
All Other Inputs  
150  
150  
150  
µA  
IEE  
Power Supply Current  
mA  
10E  
100E  
145 174  
145 174  
145 174  
125 174  
145  
167  
174  
200  
Note:  
1. Applies to BUS outputs only. Measured with VTT = 2.10V.  
AC ELECTRICAL CHARACTERISTICS  
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND  
TA = 0°C  
TA = +25°C  
TA = +85°C  
Symbol  
Parameter  
Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit  
Condition  
tPD  
Propagation Delay to Output  
CLK to Q  
CLK to BUS  
ABUSDIS  
SYNCEN  
ps  
450  
800  
500  
800  
1000 450  
1800 800  
1500 500  
1800 800  
1000 450  
1800 800  
1500 500  
1800 800  
1000  
1800  
1500  
1800  
tS  
Set-up Time  
BUS  
SBUSEN  
Data, S-IN  
TEN, REN, SCAN  
ps  
ps  
350  
100  
400  
550  
350  
100  
400  
550  
350  
100  
400  
550  
tH  
Hold Time  
BUS  
SBUSEN  
Data, S-IN  
TEN, REN, SCAN  
350  
500  
350  
200  
350  
500  
350  
200  
350  
500  
350  
200  
tPW  
Minimum Pulse Width  
400  
400  
400  
ps  
ps  
tr  
tf  
Rise/Fall Time  
20% to 80% (Qn)  
20% to 80% (BUSn Rise)  
20% to 80% (BUSn Fall)  
300  
500  
300  
800 300  
1000 500  
800 300  
800  
1000 500  
800 300  
300  
800  
1000  
800  
M9999-032206  
hbwhelp@micrel.com or (408) 955-1690  
4
SY10E337  
SY100E337  
Micrel, Inc.  
28-PIN PLCC (J28-1)  
Rev. 03  
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131 USA  
TEL + 1 (408) 944-0800 FAX + 1 (408) 474-1000 WEB http://www.micrel.com  
The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use.  
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.  
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can  
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into  
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchasers  
use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchasers own risk and Purchaser agrees to fully indemnify  
Micrel for any damages resulting from such use or sale.  
© 2006 Micrel, Incorporated.  
M9999-032206  
hbwhelp@micrel.com or (408) 955-1690  
5

相关型号:

SY10E337JZTR

3-BIT SCANNABLE REGISTERED BUS TRANSCEIVER
MICREL

SY10E337_06

3-BIT SCANNABLE REGISTERED BUS TRANSCEIVER
MICREL

SY10E404

QUAD DIFFERENTIAL AND/NAND
MICREL

SY10E404JC

QUAD DIFFERENTIAL AND/NAND
MICREL

SY10E404JCTR

QUAD DIFFERENTIAL AND/NAND
MICREL

SY10E404JZ

QUAD DIFFERENTIAL AND/NAND
MICREL

SY10E404JZTR

QUAD DIFFERENTIAL AND/NAND
MICREL

SY10E404_06

QUAD DIFFERENTIAL AND/NAND
MICREL

SY10E416

QUINT DIFFERENTIAL LINE RECEIVER
MICREL

SY10E416JC

QUINT DIFFERENTIAL LINE RECEIVER
MICREL

SY10E416JCTR

QUINT DIFFERENTIAL LINE RECEIVER
MICREL

SY10E416JI

QUINT DIFFERENTIAL LINE RECEIVER
MICREL